HomeMy WebLinkAbout0905.97.23-CAR 51PE ENTRY GARAGE
1/411 : 11-011
2x6 WALL AT 510E
0
HAR
1/411 ❑ 11 -011
v
oar
c�
' x
I,
x
en
PE ENTRY GAR
\�J
'I
i
3.1
FIRST FLOOR PLAN
1/411 ; 1141
z
3.1
NOTE : ALL PIMEN51ON5 ARE FROM FACE OF STUD TO
FACE OF 5TUP. ALL 5TU175 ARE 3 1/2' UNLF-55 NOTED.
ALL PIMEN51ON5 PRE5ENTEP HERE ARE FRAME
PIMEN51ON5 ONLY - 5EE 5HT. 1.1 FOR FOUNDATION
FOOTPRINT.
REVIEW ALL WINDOW HPR HEIC4IT5 PER PLATE HT. AND
VERIFY W/ ELEVATION5 AND CORNICE PETAIL5
'E:
JD J015T5
JTINUOU5
MIN. 811
iT WINDOW
)GH OPNG.5
0
d-
d-
11-101/2"
Z-361Z
'Ax 12° ML HDR
i
1,-10 1/211L 11.911;
NOTE5 :
I. ALL CASED OPEN IN65 GREATER THAN 48 DE
HOLD HEADER T16HT TO PLATE
2. ALL BI-FOLO DOORS R.0.'5 = 1 1/2" WIDER T ROOF
HEADER HT. = 82" AFF
3. ALL 51 -PA55 DOORS R.O.'5 : 5AME A5 DOOR
HEADER HT = 83" AFF
4. 2x BLOCK IN6 UNDER ALL EXTERIOR 5WIN6 DOORS
5. Ix BLOCK IN6 UNDER ALL EXTERIOR 5L ID ING 0OOR5
6. TOWEL BAR5 (TB) OVER CABINETS AND TOILETS
BLOCKING TO BE 55" AFF TO CL
7. TOWEL BAR5 (TB) NOT OVER CABINETS AND TOILETS
BLOCKING TO BE 39" AFF TO GL
8. BLOCKING FOR T155UE 4OLDER5 (T H) TO BE 24" AFF
—ALL EXTERIOR HEADERS ARE 2-2x12
NOTE:
FIELD CHECK ALL
APPROPRIATE AND
CURRENT DETAILS
FOR TH15 PROJECT
PRIOR TO START
OF CONSTRUCTION
NOTE=
ERROR5 AND OM15510N5 WHICH MAY OCCUR IN THE CONTRACT
POCUMENT5 SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT, IN WRITING, AND WRITTEN IN5TRUCTION SHALL
Be OBTAINED PRIOR TO PROCEEPW WITH CON5TRUCTION.
THE CONTRACTOR SHALL BE WLO ReVONSIBL.E FOR ANY
ERRORS, P15CREPANCIES OR OM15510N5 FOR WHICH THE
CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR
TO CON5TRUCTION AND /OR FABRICATION OF THE WORK.
N
O
�I
N
N
N
N
N
L
G. M IGHAE
WANCOL
Architects / Cows
1365 5henandoah
Rochester Hills
Michigan 48306
(313) 656-1187'
C F
Project
IN IAN,
D IV 15 1(
12220 Forth Meril
Suite #185
Carmel, Indiana 41
50dvision / Pian
W I N05C
Job No.
W I N05C
Date
15SUE
Sheet Titie
F IR5T
FLOOR
PLAN
Sheet No.
2.1
5HT of
Field verify all dimensions
DO NOT SCALE DRA WINGS!
551-0°
NO'
241.811
01
161.811
131.811
601
' C01
i II
14-10
I II
9-10
6141
6-I
i II
4-6
I II
16-1
TO
I
'
PA:
41.811
616 I/2° 31 -7 1/211
41 -gll
51.111
21 -911 31.411
31.411 , 21.911
61 -$" 1 71.011
ROl
010l
07
4212
I
; 2 -2x10 HDR
Z -Zx12 HOR
4212
'
2x6 WALL
• - - -- --------------------
34 1/2' SILL HT
6' PREFAB FIREPLACE
o
0
2 -2x10 H12R
W/ HEARTH AND SURROUND
PER LOCAL GORE
o
N
-2x 3306
N
— 48 4 -5L
o 6068 SGD
-
-I
?k¢
'-ZI-4 3672 3612
3672 3 ? +A
--
--
LA�JNDRY
1 191o'
9 0 LLG
2 -2x12 --- -
- - -- ----- - - - - -- --
0 1 X 1
I �
� �
- - - - -- -----------------------
4 — — —3-1
¢
- - - - -�
3[4 x 91/2* MCBI►� —if
414
NOOK
910° LLG
ARING POINT FOR BEAM ABOVE
FAM ILY
2 -2x12 WR
-
N
N
VINYL
I �_______________
--
VINYL
_
N
_
N
___ ___y
32' H KNEE WAL
N rn
2 -STORY
CARPET
�,
1/211 1511111 –°
81-111/2°
81-101/211
ti
161-1°
co
13-41/2
K ITGI-�' N
FURNACE FLUE
STRAIGHT RUN
SOLID BLBKL TO
BEARING BELOW
°
LIVING �
o
_
�,
:0
—
2/9
910' GLG
;
u�
°Q=
-�
TO ROOF ABOVE
-
�,
X'
I
910' GLG
CARPET °
o
o
VINYL
I
'
0
�1
- -_
—
— — — — — — — "5TRINCER
2x10 FLOOR J015T5
—
�,
?
N
- - -� - --
`-- - -- - -�
°
o
°I I
'—°
12 OL.OVER CLIP 5per' %/
SEE DETAIL +���
\� +�
���,y� �,)
BEAfiING
2' I° 3'-8 1/211
31.211
101.311
41.011 N11
�,
1 4'-011
B'-6 13
ti
��� 3' 3°
`�`�
�� 4' 4° -
312° 5'-10 I /211
WALL
STACK
0
3 4 9 1 �
2° H KNEEWALL
FRAMING
2/0
1
6101 HI GO-
LVL
2/B
Up
UP 15 R I
12 R
2 -2x10 HDR =
"�
N
`V N
-----
-- - - - - --
2/8 pWDR
3066
2 3 4 516
8
�'
41-1 I/2"
910° CL6
3' 1�' S'-I° TILE
o
2 -2x12 HPR
\
1
ART NIC
5HELF 32 -
AFF -HPR
2/6
f51(;
---------- ---- - - - - --
- --
-------------------------- - - - - --
- - - --
- - - - - - --
810' AFF
r(�4
n
a
;
CC
I
IRI
6
,
° FL. JST.SHA GEREP
o TO BOND J5 T. - BOLT _-
o DINING
°
I
I
5
4
°
BOND J5T TO GRIPER
TRU55 U51N6 5/8' AB15
°'
0
9b' GLG -
I
3
�'
°
-
N
6' u. STAGGERS
CARPET
o`
I
vo o
—
110
I
U.1
I II
20 -i
I
I
I it
I1 -I
I II
3-7
51,511
I II N
13-1
I
II 71
i
-
C-4
�i� �r MFR
_
i FOYER
DBL Z/o
1 LI13RARY
o
�,
91♦0'1 ae
N
i
CARPET
ATTIC -
GARAGE
I
I ACCE55 I
3 0 W 2-12 S.L.
REF ELF-V.5
L — — _ J
REF. ELEVATIONS
x6 BALLOON
0
FRAME WALL
—
_
DBL 2x6 12' OG
N
_
OD
O
ROOF TRU55E5 24' OC.
- 13/4' x 16' ML HPR
'
W/ 8' x 4' x I /2' LLV BOLTED
'
161 710H GAR DOOR
W/ 3/4' THRU BOLT5 t 12' OG
x
TO CARRY
BRICK GABLE PER ELEVATION
104'
101-411
1 I'-4 12"
71-911
15'-2 1/2"
201-8'
341411
i
3.1
FIRST FLOOR PLAN
1/411 ; 1141
z
3.1
NOTE : ALL PIMEN51ON5 ARE FROM FACE OF STUD TO
FACE OF 5TUP. ALL 5TU175 ARE 3 1/2' UNLF-55 NOTED.
ALL PIMEN51ON5 PRE5ENTEP HERE ARE FRAME
PIMEN51ON5 ONLY - 5EE 5HT. 1.1 FOR FOUNDATION
FOOTPRINT.
REVIEW ALL WINDOW HPR HEIC4IT5 PER PLATE HT. AND
VERIFY W/ ELEVATION5 AND CORNICE PETAIL5
'E:
JD J015T5
JTINUOU5
MIN. 811
iT WINDOW
)GH OPNG.5
0
d-
d-
11-101/2"
Z-361Z
'Ax 12° ML HDR
i
1,-10 1/211L 11.911;
NOTE5 :
I. ALL CASED OPEN IN65 GREATER THAN 48 DE
HOLD HEADER T16HT TO PLATE
2. ALL BI-FOLO DOORS R.0.'5 = 1 1/2" WIDER T ROOF
HEADER HT. = 82" AFF
3. ALL 51 -PA55 DOORS R.O.'5 : 5AME A5 DOOR
HEADER HT = 83" AFF
4. 2x BLOCK IN6 UNDER ALL EXTERIOR 5WIN6 DOORS
5. Ix BLOCK IN6 UNDER ALL EXTERIOR 5L ID ING 0OOR5
6. TOWEL BAR5 (TB) OVER CABINETS AND TOILETS
BLOCKING TO BE 55" AFF TO CL
7. TOWEL BAR5 (TB) NOT OVER CABINETS AND TOILETS
BLOCKING TO BE 39" AFF TO GL
8. BLOCKING FOR T155UE 4OLDER5 (T H) TO BE 24" AFF
—ALL EXTERIOR HEADERS ARE 2-2x12
NOTE:
FIELD CHECK ALL
APPROPRIATE AND
CURRENT DETAILS
FOR TH15 PROJECT
PRIOR TO START
OF CONSTRUCTION
NOTE=
ERROR5 AND OM15510N5 WHICH MAY OCCUR IN THE CONTRACT
POCUMENT5 SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT, IN WRITING, AND WRITTEN IN5TRUCTION SHALL
Be OBTAINED PRIOR TO PROCEEPW WITH CON5TRUCTION.
THE CONTRACTOR SHALL BE WLO ReVONSIBL.E FOR ANY
ERRORS, P15CREPANCIES OR OM15510N5 FOR WHICH THE
CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR
TO CON5TRUCTION AND /OR FABRICATION OF THE WORK.
N
O
�I
N
N
N
N
N
L
G. M IGHAE
WANCOL
Architects / Cows
1365 5henandoah
Rochester Hills
Michigan 48306
(313) 656-1187'
C F
Project
IN IAN,
D IV 15 1(
12220 Forth Meril
Suite #185
Carmel, Indiana 41
50dvision / Pian
W I N05C
Job No.
W I N05C
Date
15SUE
Sheet Titie
F IR5T
FLOOR
PLAN
Sheet No.
2.1
5HT of
Field verify all dimensions
DO NOT SCALE DRA WINGS!