Loading...
HomeMy WebLinkAbout0905.97.23-CAR 51PE ENTRY GARAGE 1/411 : 11-011 2x6 WALL AT 510E 0 HAR 1/411 ❑ 11 -011 v oar c� ' x I, x en PE ENTRY GAR \�J 'I i 3.1 FIRST FLOOR PLAN 1/411 ; 1141 z 3.1 NOTE : ALL PIMEN51ON5 ARE FROM FACE OF STUD TO FACE OF 5TUP. ALL 5TU175 ARE 3 1/2' UNLF-55 NOTED. ALL PIMEN51ON5 PRE5ENTEP HERE ARE FRAME PIMEN51ON5 ONLY - 5EE 5HT. 1.1 FOR FOUNDATION FOOTPRINT. REVIEW ALL WINDOW HPR HEIC4IT5 PER PLATE HT. AND VERIFY W/ ELEVATION5 AND CORNICE PETAIL5 'E: JD J015T5 JTINUOU5 MIN. 811 iT WINDOW )GH OPNG.5 0 d- d- 11-101/2" Z-361Z 'Ax 12° ML HDR i 1,-10 1/211L 11.911; NOTE5 : I. ALL CASED OPEN IN65 GREATER THAN 48 DE HOLD HEADER T16HT TO PLATE 2. ALL BI-FOLO DOORS R.0.'5 = 1 1/2" WIDER T ROOF HEADER HT. = 82" AFF 3. ALL 51 -PA55 DOORS R.O.'5 : 5AME A5 DOOR HEADER HT = 83" AFF 4. 2x BLOCK IN6 UNDER ALL EXTERIOR 5WIN6 DOORS 5. Ix BLOCK IN6 UNDER ALL EXTERIOR 5L ID ING 0OOR5 6. TOWEL BAR5 (TB) OVER CABINETS AND TOILETS BLOCKING TO BE 55" AFF TO CL 7. TOWEL BAR5 (TB) NOT OVER CABINETS AND TOILETS BLOCKING TO BE 39" AFF TO GL 8. BLOCKING FOR T155UE 4OLDER5 (T H) TO BE 24" AFF —ALL EXTERIOR HEADERS ARE 2-2x12 NOTE: FIELD CHECK ALL APPROPRIATE AND CURRENT DETAILS FOR TH15 PROJECT PRIOR TO START OF CONSTRUCTION NOTE= ERROR5 AND OM15510N5 WHICH MAY OCCUR IN THE CONTRACT POCUMENT5 SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, IN WRITING, AND WRITTEN IN5TRUCTION SHALL Be OBTAINED PRIOR TO PROCEEPW WITH CON5TRUCTION. THE CONTRACTOR SHALL BE WLO ReVONSIBL.E FOR ANY ERRORS, P15CREPANCIES OR OM15510N5 FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR TO CON5TRUCTION AND /OR FABRICATION OF THE WORK. N O �I N N N N N L G. M IGHAE WANCOL Architects / Cows 1365 5henandoah Rochester Hills Michigan 48306 (313) 656-1187' C F Project IN IAN, D IV 15 1( 12220 Forth Meril Suite #185 Carmel, Indiana 41 50dvision / Pian W I N05C Job No. W I N05C Date 15SUE Sheet Titie F IR5T FLOOR PLAN Sheet No. 2.1 5HT of Field verify all dimensions DO NOT SCALE DRA WINGS! 551-0° NO' 241.811 01 161.811 131.811 601 ' C01 i II 14-10 I II 9-10 6141 6-I i II 4-6 I II 16-1 TO I ' PA: 41.811 616 I/2° 31 -7 1/211 41 -gll 51.111 21 -911 31.411 31.411 , 21.911 61 -$" 1 71.011 ROl 010l 07 4212 I ; 2 -2x10 HDR Z -Zx12 HOR 4212 ' 2x6 WALL • - - -- -------------------- 34 1/2' SILL HT 6' PREFAB FIREPLACE o 0 2 -2x10 H12R W/ HEARTH AND SURROUND PER LOCAL GORE o N -2x 3306 N — 48 4 -5L o 6068 SGD - -I ?k¢ '-ZI-4 3672 3612 3672 3 ? +A -- -- LA�JNDRY 1 191o' 9 0 LLG 2 -2x12 --- - - - -- ----- - - - - -- -- 0 1 X 1 I � � � - - - - -- ----------------------- 4 — — —3-1 ¢ - - - - -� 3[4 x 91/2* MCBI►� —if 414 NOOK 910° LLG ARING POINT FOR BEAM ABOVE FAM ILY 2 -2x12 WR - N N VINYL I �_______________ -- VINYL _ N _ N ___ ___y 32' H KNEE WAL N rn 2 -STORY CARPET �, 1/211 1511111 –° 81-111/2° 81-101/211 ti 161-1° co 13-41/2 K ITGI-�' N FURNACE FLUE STRAIGHT RUN SOLID BLBKL TO BEARING BELOW ° LIVING � o _ �, :0 — 2/9 910' GLG ; u� °Q= -� TO ROOF ABOVE - �, X' I 910' GLG CARPET ° o o VINYL I ' 0 �1 - -_ — — — — — — — — "5TRINCER 2x10 FLOOR J015T5 — �, ? N - - -� - -- `-- - -- - -� ° o °I I '—° 12 OL.OVER CLIP 5per' %/ SEE DETAIL +��� \� +� ���,y� �,) BEAfiING 2' I° 3'-8 1/211 31.211 101.311 41.011 N11 �, 1 4'-011 B'-6 13 ti ��� 3' 3° `�`� �� 4' 4° - 312° 5'-10 I /211 WALL STACK 0 3 4 9 1 � 2° H KNEEWALL FRAMING 2/0 1 6101 HI GO- LVL 2/B Up UP 15 R I 12 R 2 -2x10 HDR = "� N `V N ----- -- - - - - -- 2/8 pWDR 3066 2 3 4 516 8 �' 41-1 I/2" 910° CL6 3' 1�' S'-I° TILE o 2 -2x12 HPR \ 1 ART NIC 5HELF 32 - AFF -HPR 2/6 f51(; ---------- ---- - - - - -- - -- -------------------------- - - - - -- - - - -- - - - - - - -- 810' AFF r(�4 n a ; CC I IRI 6 , ° FL. JST.SHA GEREP o TO BOND J5 T. - BOLT _- o DINING ° I I 5 4 ° BOND J5T TO GRIPER TRU55 U51N6 5/8' AB15 °' 0 9b' GLG - I 3 �' ° - N 6' u. STAGGERS CARPET o` I vo o — 110 I U.1 I II 20 -i I I I it I1 -I I II 3-7 51,511 I II N 13-1 I II 71 i - C-4 �i� �r MFR _ i FOYER DBL Z/o 1 LI13RARY o �, 91♦0'1 ae N i CARPET ATTIC - GARAGE I I ACCE55 I 3 0 W 2-12 S.L. REF ELF-V.5 L — — _ J REF. ELEVATIONS x6 BALLOON 0 FRAME WALL — _ DBL 2x6 12' OG N _ OD O ROOF TRU55E5 24' OC. - 13/4' x 16' ML HPR ' W/ 8' x 4' x I /2' LLV BOLTED ' 161 710H GAR DOOR W/ 3/4' THRU BOLT5 t 12' OG x TO CARRY BRICK GABLE PER ELEVATION 104' 101-411 1 I'-4 12" 71-911 15'-2 1/2" 201-8' 341411 i 3.1 FIRST FLOOR PLAN 1/411 ; 1141 z 3.1 NOTE : ALL PIMEN51ON5 ARE FROM FACE OF STUD TO FACE OF 5TUP. ALL 5TU175 ARE 3 1/2' UNLF-55 NOTED. ALL PIMEN51ON5 PRE5ENTEP HERE ARE FRAME PIMEN51ON5 ONLY - 5EE 5HT. 1.1 FOR FOUNDATION FOOTPRINT. REVIEW ALL WINDOW HPR HEIC4IT5 PER PLATE HT. AND VERIFY W/ ELEVATION5 AND CORNICE PETAIL5 'E: JD J015T5 JTINUOU5 MIN. 811 iT WINDOW )GH OPNG.5 0 d- d- 11-101/2" Z-361Z 'Ax 12° ML HDR i 1,-10 1/211L 11.911; NOTE5 : I. ALL CASED OPEN IN65 GREATER THAN 48 DE HOLD HEADER T16HT TO PLATE 2. ALL BI-FOLO DOORS R.0.'5 = 1 1/2" WIDER T ROOF HEADER HT. = 82" AFF 3. ALL 51 -PA55 DOORS R.O.'5 : 5AME A5 DOOR HEADER HT = 83" AFF 4. 2x BLOCK IN6 UNDER ALL EXTERIOR 5WIN6 DOORS 5. Ix BLOCK IN6 UNDER ALL EXTERIOR 5L ID ING 0OOR5 6. TOWEL BAR5 (TB) OVER CABINETS AND TOILETS BLOCKING TO BE 55" AFF TO CL 7. TOWEL BAR5 (TB) NOT OVER CABINETS AND TOILETS BLOCKING TO BE 39" AFF TO GL 8. BLOCKING FOR T155UE 4OLDER5 (T H) TO BE 24" AFF —ALL EXTERIOR HEADERS ARE 2-2x12 NOTE: FIELD CHECK ALL APPROPRIATE AND CURRENT DETAILS FOR TH15 PROJECT PRIOR TO START OF CONSTRUCTION NOTE= ERROR5 AND OM15510N5 WHICH MAY OCCUR IN THE CONTRACT POCUMENT5 SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT, IN WRITING, AND WRITTEN IN5TRUCTION SHALL Be OBTAINED PRIOR TO PROCEEPW WITH CON5TRUCTION. THE CONTRACTOR SHALL BE WLO ReVONSIBL.E FOR ANY ERRORS, P15CREPANCIES OR OM15510N5 FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR TO CON5TRUCTION AND /OR FABRICATION OF THE WORK. N O �I N N N N N L G. M IGHAE WANCOL Architects / Cows 1365 5henandoah Rochester Hills Michigan 48306 (313) 656-1187' C F Project IN IAN, D IV 15 1( 12220 Forth Meril Suite #185 Carmel, Indiana 41 50dvision / Pian W I N05C Job No. W I N05C Date 15SUE Sheet Titie F IR5T FLOOR PLAN Sheet No. 2.1 5HT of Field verify all dimensions DO NOT SCALE DRA WINGS!