Loading...
HomeMy WebLinkAbout0917.97.3NOTE: SILL PLATE TO BE FLUSH R -13 BATT INSULATION WITH CRAWL SIDE OF W/ 2 MIL. VAPOR BARRIER FOUNDATION WALL (2) RISER AT 1 -3/4' EACH (1) 9' TREAD 4' CONC. SLAB ON GRADE SLOPE 2' TO DOOR v , L , v , L , V , L , V v v v v v o °o °o °o °o °o °° 00 00 00 00 00 00 G' -8' MIN. 00 0° GRANULAR FILL 00. o O° 00 o° o° o° o° o° V ° 00 v • 1' -4' PROVIDE TREATED BAND BOARD AT CONCRETE SLAB AREA 112' EXPANSION MATERIAL 3/4' FLOOR DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT 2X4 TREATED PLATE TYPICAL FOUNDATION WALL: x 8' CAP BLOCK (3) 8' LINE BLOCK SILL ANCHOR BOLTS @ G' -0" O.C. x 16'X8• CONCRETE FOOTING PERIMETER INSULATION DOWN TO GRANULAR FILL 4' MIN. GRANULAR FILL UNDER 6 MIL. VISOUEEN VAPOR BARRIER FOUNDATION HALL at GARAGE REAR CRAWL and PART'L BASEMENT FOUNDATIONS NOTE: OFFSET Fn 13 BATT INSULATION FROM FAC 2 MIL. VAPOR BARRIER 4' RIGID INSULATION ICK VENEER SLOPE 1/8' PER FOOT 0 0 v ° °° o c°d 0d o ° ° 00 00 000 0 00 00 00 0000 0 °o °o °o 0 0 O o 00 0. 00 00 00 °o ° °o °° o 00 o p v c v d ° o 0 0 °o O O O °° ° p ° ° v ° v, ° V ° , V L J FOUNDATION WALL of PORCH - BRICK CRAWL FOUNDATIONS 3/4' FLOOR DECKING SEE FLOOR FRAMING PI AN FOR JOIST LAYOUT 2X4 TREATED PLATE TYPICAL FOUNDATION WALL: x 8' CAP BLOCK x (3) 8' LINE BLOCK x SILL ANCHOR BOLTS o 6' -0' O.C. x 16'X8' CONCRETE FOOTING PERIMETER INSULATION DOWN TO GRANULAR FILL 4' MIN. GRANULAR FILL UNDER 6 MIL. VISOUEEN VAPOR BARRIER 4' CONC. SLAB ON GRADE W/ THICKENED EDGE TYPICAL FOUNDATIO WALL: x 4' CAP BLOCK x (4) 8' LINE BLOCK x 16'X8' CONCRETE FOOTING \ 1' -11' MIN. GRANULAR FILL det.estF46 det.estF48 PART'L and FULL BASEMENT FOUNDATIONS det.estF3'j NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL R -13 BATT INSULATI W/ 2 MIL. VAPOR BARR I DRYWALL 3/4' DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT 8' POURED CONC. WALL 0 3/4' RIGID INSULATION SIDING Ix WOOD BAND BOARD W/ ALUM. DRIP CAP (SEE ELEV.) 4' CONC. SLAB ON GRADE 2X4 TREATED SILL PLATE 6' -8' MIN. GRANULAR FILL ANCHOR BOLTS AT 6'-0" 0. C. FLOOR SYSTEM at, FOUNDATION WALL - SIDING PART'L and FULL BASEMENT FOUNDATIONS NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL 3/4' FLOOR DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT 2X4 TREATED PLATE ° v TYPICAL FOUNDATION WALL: j ° p OVERDIG x 8" POURED CONCRETE WALL x SILL ANCHOR BOLTS ® 6' -0' O.C. �_ ° J x 16'X8' CONCRETE FOOTIN J J v Q , 4' CONCRETE SLAB ON GRADE a J W/ 6 MIL. VAPOR BARRIER o °o °o °o 00 00 00 00 J r L , r L ° d ° ° ° d ° ° , o °o °o °o 4' MIN. , d , ° , d V ° ° ° ° ° ° ° °o °o 00 GRANULAR FILL o° o° 00 00 00 d ° �d °00 00 00 L ° 00° O° L ° V L d d O O 4' DRAIN TILE FOUNDATION WALL of HOUSE - SIDING PART'L and FULL-BASEMENT FOUNDATIONS det.estF38 R -13 BATT INSULATION W/ 2 MIL. VAPOR BARRIER 3/4' RIGID INSULATION SIDING GRADE Ix BAND BOARD W/ DRIP EDGE '777 (SEE ELEV. ) GRANULAR FILL TO 12' ABOVE TOP OF FOOTING 4' DRAIN TILE det.estF31 SIDING PROVIDE TREATED R -13 BATT INSULATION NOTE:-OFFSET FACE OF STUD 112' BAND BOARD AT W/ 2 MIL. VAPOR BARRIER FROM FACE OF FOUND. WALL CONCRETE SLAB AREA NOTE: OFFSET FACE OF STUD 112' Q 3/4' RIGID INSULATION 3/4' FLOOR DECKING FROM FACE OF FOUND. WALL c\j 2X4 TREATED PLATE w GRADE x 16'x24* CONT. CONC. TRENCH 4' CONC. SLAB ON GRADE SLOPE 1 /8' PER FOOT Ln ° °0 °° SEE FLOOR FRAMING z W/ (2) r4 BARS CONT. ON 3/4' FLOOR DECKING PLAN FOR JOIST LAYOUT ♦ d' ° • d i CERTIFIED COMPACTED FILL W/ o L L , d L , L d° d ° d V° d ° d V° d PERIMETER INSULATION ° W /THICKENED EDGE r 1 d V ° ° V ° V °° ° ° ° ° ° ° 'B ° °° ° °° ° O° ° °° °o °° °o °° °o d ° v o 0 o 0 o o 0 0 71 0C 00 d TYPICAL FOUNDATION WALL: 00 00 00 o °o °o o x 8' CAP BLOCK GARAGE - o0 00 00 00 °o ° SEE FLOOR FRAMING °° ° ° ° °° d ° ° °p °°° d p ° ° °° C 4�° °� °��° °� x 16'X8' CONCRETE FOOTING FOR JOIST LAYOUT 00 ° V ° ° ° o °o °o °o °o °o °o °o 4' MIN. GRANULAR FILL ° ° ° ° ° d cr p ° ° ° ° ° p 00 0 00 00 00 00 00 VAPOR BARRIER CY = 2X4 TREATED 1 1/2' 0 ro 00 o' 00 00 00 00 0 p W000 PLATE 00 0 00 00 00 00 00 v ° V° ° 00 O° 00 Oo o° oo O° 0 00 00 00 00 O° O 00 p pp ° TYPICAL FOUNDATION WALL: TYPICAL FOUNDATION WALL: x 4' CAP BLOCK °o °o °o °o °o °o °o °o ° ° ° x 8' POURED CONCRETE WALL * (4) 8' LINE BLOCK °0 0 ° 00 00 00 00 00 V a o ° �-. x SILL ANCHOR BOLTS o 6'-0* 0. C. x 16'X8' CONCRETE FOOTING O° O° O° O° ° ° ° O° O ° ° ° ° LJ J x 16'X8' CONCRETE FOOTING 0 00 00 0 00 o p XXA °o ° V ° d 3 4' CONC. SLAB ON GRADE GRANULAR FILL TO pp °° 1' -11' MIN, a° ° ° W/ 6 MIL. VAPOR BARRIER 12' ABOVE TOP OF ° ° GRANULAR FILL ° ° CONCRETE FOOTING d VL J d p L p° d 4' DRAIN TILE 00 00 00 00 00 ° ° °o °o °o °o �V ° 4' GRANULAR FILL 4' DRAIN TILE °o °o °o °o 00 00 00 00 00 ° ° d 00 00 00 00 00 ° ° ° ° v ° ° ° ♦ v Oo Oo Oo O v Oo O O° 00 O° 00 00 ° 00 00 0 lo d° v, d d0 O° O° O° FOUNDATION WALL at PORCH - SIDING PART'L and FULL BASEMENT FOUNDATIONS det.estF3'j NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL R -13 BATT INSULATI W/ 2 MIL. VAPOR BARR I DRYWALL 3/4' DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT 8' POURED CONC. WALL 0 3/4' RIGID INSULATION SIDING Ix WOOD BAND BOARD W/ ALUM. DRIP CAP (SEE ELEV.) 4' CONC. SLAB ON GRADE 2X4 TREATED SILL PLATE 6' -8' MIN. GRANULAR FILL ANCHOR BOLTS AT 6'-0" 0. C. FLOOR SYSTEM at, FOUNDATION WALL - SIDING PART'L and FULL BASEMENT FOUNDATIONS NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL 3/4' FLOOR DECKING SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT 2X4 TREATED PLATE ° v TYPICAL FOUNDATION WALL: j ° p OVERDIG x 8" POURED CONCRETE WALL x SILL ANCHOR BOLTS ® 6' -0' O.C. �_ ° J x 16'X8' CONCRETE FOOTIN J J v Q , 4' CONCRETE SLAB ON GRADE a J W/ 6 MIL. VAPOR BARRIER o °o °o °o 00 00 00 00 J r L , r L ° d ° ° ° d ° ° , o °o °o °o 4' MIN. , d , ° , d V ° ° ° ° ° ° ° °o °o 00 GRANULAR FILL o° o° 00 00 00 d ° �d °00 00 00 L ° 00° O° L ° V L d d O O 4' DRAIN TILE FOUNDATION WALL of HOUSE - SIDING PART'L and FULL-BASEMENT FOUNDATIONS det.estF38 R -13 BATT INSULATION W/ 2 MIL. VAPOR BARRIER 3/4' RIGID INSULATION SIDING GRADE Ix BAND BOARD W/ DRIP EDGE '777 (SEE ELEV. ) GRANULAR FILL TO 12' ABOVE TOP OF FOOTING 4' DRAIN TILE det.estF31 SIDING PROVIDE TREATED R -13 BATT INSULATION NOTE:-OFFSET FACE OF STUD 112' BAND BOARD AT W/ 2 MIL. VAPOR BARRIER FROM FACE OF FOUND. WALL CONCRETE SLAB AREA W Ln J Q 3/4' RIGID INSULATION 3/4' FLOOR DECKING c\j 2X4 TREATED PLATE w GRADE x 16'x24* CONT. CONC. TRENCH °s °.- °.1 00* Ln ° °0 °° SEE FLOOR FRAMING z W/ (2) r4 BARS CONT. ON SLOPE 1/8' PER FOOT PLAN FOR JOIST LAYOUT ♦ d' ° • d i CERTIFIED COMPACTED FILL W/ ° ° ♦ L L , d L , L d° d ° d V° d ° d V° d PERIMETER INSULATION ° r 1 d p ° r 1 d V ° ° V ° V °° ° ° ° ° ° ° DOWN TO GRANULAR FILL ° °° ° °° ° O° ° °° °o °° °o °° °o d ° v o 0 o 0 o o 0 0 71 0C 00 0C 00 °o °o TYPICAL FOUNDATION WALL: 00 00 00 o °o °o o x 8' CAP BLOCK GARAGE - o0 00 00 00 °o ° x (3) 8' LINE BLOCK °° ° ° ° °° x SILL ANCHOR BOLTS Q G'-O' O.C. 00 ° ° °o ' x 16'X8' CONCRETE FOOTING 00 00 ° °° o° 4' MIN. GRANULAR FILL ° ° ° ° ° d cr p ° ° ° ° ° p UNDER 6 MIL. VISOUEEN Oo ° p °d v ° ° ° ° °� V V ° VAPOR BARRIER CY = FOUNDATION WALL at PATIO - SlOING CRAWL and PART'L BASEMENT FOUNDATIONS 4' CONC. SLAB ON GRADE W /THICKENED EDGE 1 112' 16' -18' MIN. GRANULAR FILL SEE TYPICAL FOUNDATION WALL u NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL 3/4' FLOOR DECKING 2X4 TREATED PLATE ' SEE FLOOR FRAMING PLAN FOR JOIST LAYOUT (2) RISER AT 1 -3/4' EACH SLOPE 2' TO DOOR Kea (1) 9' TREAD PERIMETER INSULATION I vv vv ° 00 ° 00 ° 00 ° 00 ° 00 ° 00 DOWN TO GRANULAR FILL Oa ° 00 00 00 00 Mo.. °0 TYPICAL FOUNDATION WALL: o x 8' CAP BLOCK °o x (3) 8' LINE BLOCK x SILL ANCHOR BOLTS a 6' -0' O.C. ° ° ° ° ° ° ° x 16'X8' CONCRETE FOOTING ° ° V ° V ° ° ° 4' MIN. GRANULAR FILL 1' -4' UNDER 6 MIL. VISOUEEN VAPOR BARRIER FOUNDATION WALL at GARAGE REAR CRAWL ah d BASEMENT FOUNDATIONS det . es t F28 NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOlM. WALL BRICK VENEER 112' INSULATION SIE ATHING 4' CONC. SLAB ON GRADE W Ln J Q YPICAL FOUNDATION WALL: 6'-B' MIN. GRAN, FILL x 8" 'L* BLOCK ON 8' C.N.U. w GRADE x 16'x24* CONT. CONC. TRENCH °s °.- °.1 00* FOOTING ON VIRGIN SOIL OR ° °0 °° °° °° z W/ (2) r4 BARS CONT. ON C;J d ° d ♦ d v ♦ d' ° • d i CERTIFIED COMPACTED FILL W/ ° ° ♦ d d MIN. BEARING CAPACITY OF 11 d 2,000 P.S.F. A V d ♦ ' ♦ d z C0 d ° v ° • e o LL_ W A d �i FOUNDATION WALL at GARAGE - BRICK TWO -STORY SLAB FOUNDATIONS de t . as t F NOTE: OFFSET FACE OF STUD 112' FROM FACE OF FOUND. WALL 112' DRYWALL 112" INSULATION SHEATHING BRICK VENEER cn ANCHOR BOLTS AT 6' O.C. FIN. GRADE 4 CONC, SLAB ON GRADE GRANULAR FILL °o °o °o °° °° °° TYPICAL FOUNDATION WALL: v x 8' CAP BLOCK ON 12' CAP BLOCK x 16'x24' CONT. CONC. TRENCH Cu a � a v FOOTING ON VIRGIN SOIL OR W/ (2) #4 BARS CONT. ON CERTIFIED COMPACTED FILL W/ MIN. BEARING CAPACITY OF ",000 P.S.F. 1 -4' FOUNDATION WALL at GARAGE - BRICK RETURNS det.estF29 TWO -STORY SLAB FOUNDATIONS det.estF21 6 . . ONl N O V. q a y � N r r m V u d cm cn �. W L�s E a� z 28 DATE: I0 25.95 Ln J Q w w w 4 J z C;J oLn� z 0 Z z C0 o LL_ W C-0 z cr w w w O = CY = 28 DATE: I0 25.95 J Q W 4 J z 3 oLn� Z z C0 o LL_ 28 DATE: I0 25.95