Loading...
HomeMy WebLinkAbout0928.97.1LO M rn Cv 0 v N CU C 7 .ti L LL J r` 0 M r, Cn LO 0 0 1 ­0 M L M J H G I E C C 0 n i i 2 3 4 0 SANITARY SEWER TABLE SIR # STA BASE OFFSET LT/RT TYPE TC 17 0+10.14 B 30.00' RT MANHOLE 756.30 18 1 +46.10 B 30.00' RT MANHOLE 755.40 19 3+35.55 B 46.70' RT MANHOLE 757.50 20 14+66.67 A 30.00' LT MANHOLE 759.50 21 12 +10.67 A 30.00' LT MANHOLE 763.50 22 4+69.41 B 35.00' RT MANHOLE 756.20 23 13+14.42 C 40.00' LT MANHOLE 762.30 24 14 +71.55 C 40.00' LT MANHOLE 760.00 28 11 +41.40 C 30.12' LT MANHOLE 762.50 29 8+46.19 C 30.50' LT MANHOLE 762.00 0-- =;--- 0 0 STORM SEWER TABLE STR # STA M OFFSET LT/RT TYPE TC 119 13 +99.03 C 195.05' LT END SECTION - 120 13+81.54 C 168.21' LT MANHOLE 755.50 121 14 +05.00 C 15.00' LT CURB INLET 759.31 122 14 +05.00 C 15.00' RT CURB INLET 759.31 123 14 +53.37 C 40.00' RT MANHOLE 761.50 129 3+77.68 A 57.55' RT MANHOLE 756.50 130 5+47.72 A 40.00' RT MANHOLE 761.50 157 6 +47.18 A 15.00' RT I CURB INLET 757.00 158 3+35.97 A 15.00' LT CURB INLET 757.170 180 9 +50.00 C 15.00' RT CURB INLET 759.74 181 9 +50.00 C 15.00' LT CURB INLET 759.74 755 5 I 6 I 7 .� If =1 N H Ian -yy TYPICAL MOUNDING DETAIL 'C -C' 8 D BENCH MARKS IBM CUT & ON SOUTHEAST CORNER OF 116th STREET BRIDGE OVER COOL CREEK ELEV.- 748.83 IBM BENT SPIKE ON CENTERLINE OF 116th STREET AT THE NE. CORNER OF THE NW 1/4 OF SEC. 33- 18N -4E ELEV.- 786.14 182 14+90.91 A 48.7, RT BEEHIVE 50 REFER TO SHEETS S -10 & 11 B1 14 +51.30 C 184.23' RT BEEHIVE 763.30 . ,e.cu N,.en ern.n F nP nPP_. CI TF C A AI I TA RY Cr VJr*0 lQ i ASSUMED NORTH SCALE 1 s = 56 2 8 9 1Q 11 12 13 - Ow -, - Wo,u 000.00 aoo.00 0 000 14 HOLEY MOLEY SAY8 "DON'T DIG ai wn " 15 (CALL MONDAY - FRIDAY 7AM - 6PM) CALL TOLL FREE 1 -800- 382 -5544 FOR CALLS OUTSIDE OF INDIANA 1 -800- 428 -5200 PER INDIANA STATE LAW IS- 69 -199L IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. New Storm Sewer New Sanitary Sewer (Laterals are shown for reference only See Sanitary Plan do Profiles for Locations) Existing Contour Exiting Elevation New Pavement Grade All Other Finish Grades Storm Structure Number Sanitary Structure Number Flow Arrow Swale (rt)_... -. -- E L GENERAL NOTES: 1. IT SHALL BE THE RESPONSIBILITY OF EACH SUBCONTRACTOR TO VERIFY ALL EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF WORK. IT SHALL ALSO BE THE SUBCONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS UTILITIES FOR PROPER STAKE LOCATION OF EACH UTILITY BEFORE WORK IS STARTED. THE SUBCONTRACTOR SHALL NOTIFY IN WRITING THE OWNER OR THE ENGINEER OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN FIELD BEFORE WORK IS STARTED OR RESUMED. 2. STANDARD SPECIFICATIONS FOR CITY OF CARMEL REGIONAL WASTE DISTRICT SHALL APPLY FOR ALL SANITARY SEWERS. 3. ANY PART OF THE SANITARY OR STORM SEWER TRENCHES RUNNING UNDER PAVED AREAS TO BE BACKFILLED WITH GRANULAR MATERIAL. 4. THE SIZE AND LOCATION OF EXISTING UTILITIES SHOWN ARE PER INFORMATION PROVIDED BY THE RESPECTIVE UTILITY COMPANIES. ALL UTILITY COMPANIES SHOULD BY NOTIFIED PRIOR TO ANY EXCAVATION FOR FIELD LOCATION ' OF SERVICES. 5. SIDEWALKS SHALL BE NON- REINFORCED CONCRETE 4" THICK (6" THICK AT DRIVEWAYS) AND 4' IN WIDTH. 6. 4' CONCRETE SERVICE WALK ACROSS FRONTAGE OF EACH LOT TO BE CONSTRUCTED BY OTHERS. 7. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 8. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 9. CONTRACTOR SHALL MINIMIZE DAMAGE TO EXISTING TREES.