HomeMy WebLinkAbout1386.97.4GENERAL FRAMNG NOTES THE FOLLOWING NOTES ARE SUGGESTED MINIMAM REQUIREMENTS ONLY. DIE TO A VARIANCE OF CODES PER REGION, PLEASE REFER AND COMPLY WITH ALL YOUR LOCAL CODES. CONSULT WITH LOCAL ENGINEERS FOR ALL STRUCTURAL REQIIRENkNTS I PROVIDE PURLNS AT MID HEIGHT OF ALL WALLS. 2 ALL JOISTS AND RAFTERS SHALL BE ALIGNED OVER STUDS BELOW. 3, ALL FEADERS SHALL BE 2- 2xIO's WITH 1/7' PLYWOOD FLITCH PLATE UNLESS OTHERWISE NOTED 4, FRAMER TO INSTALL DOUBLE FLOOR JOISTS UNDER PARTITION WALL PARALLEL TO JOIST DIRECTION 5 PROVIDE Ix4 CROSS BRIDGING AT MD POINT OF SPAN OR 8'-0" O.C. MMXMJIVI N ALL FLOORS 6. ALL EXTERIOR CORNERS INSIDE AND OUTSIDE CORNERS) SHALL BE BRACED WITH 1/2"" CDX PLYWOOD NAILING SCHEDULE SHALL BE 8d COMAAONS AT 6" OC AT ALL EDGES AND 6d COMMONS AT 12" O.C. AT ALL NTERMEDIATE STUDS. (OPTION - APPROVED DIAGONAL CORNER BRACES BOTH DIRECTIONS AT ALL CORNER% 7 ALL COLUMNS OR SOLID FRAMING SHALL EXTEND DOWN THRU ALL LEVELS AND TERN"TE AT THE BASEMENT FLOOR AND BE SUPPORTED BY A THICKEN SLAB, GRADE BEAM OR FOOTING DESIGN TO CARRY LOAD. 8 PROVIDE DOUBLE 2x8 STRONGBACK AT MD SPAN FOR CEILING JOISTS WITH SPAN GREATER THAN )0'-0 9 PROVIDE COLLAR TES AT UPPER 1/3 OF VERTICAL DISTANCE BETWEEN RIDGE BOARD AND CEILING JOISTS AT 4'-0" O.0 MIAXIMI M 10. HP. VALLEY RAFTERS. AND RIDGE BOARDS SHALL BE ONE "2x"' SIZE LARGER THAN RAFTERS a ROOF DECKING SHALL BE 1/7' CDX PLYWOOD MMMRvt 12 WHERE PRE ENGNNEIIERED FLOOR AND ROOF TRUSSES ARE USED. TRUSS MANUFACTURER MUST PROVIDE SHOP DRAWINGS WHICH BEAR SEAL OF REGISTERED ENGINEER N STATE N WHICH WORK IS TO BE PERFORM®. a ALL CEILING JOISTS AND RAFTER BRACNG TO BEAR ON LOAD BEARING WqL LS DESIGNED TO CARRY LOAD THRU ALL LEVELS AND TERM"TE AT BAS� FLOOR AND BE SUPPORTED BY THICKENED SLAB GRADE BEAM OR FOOTING DESIGNED TO CARRY LOAD. 14. ALL BASEMENT WALLS, BEAMS, AND COLUMNS TO BE DESIGNED BY LOCAL STRUCTURAL ENGINEER AND MEET ALL LOCAL CODES 15 ALL SOLID FRAMING, COLUMNS, BEAMS. ETC.. TO BE DESIGNED BY LOCAL STRUCTURAL ENGINEER AND MEET ALL LOCAL CODES 16. ALL FRAMED WALL DWENSOW ARE BASED ON 2 x 4 STUDS UNLESS OTHERWISE NOTED. GENERAL NOTES 1 ALL WORK 9-IALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE NATIONAL, STATE, AND LOCAL CODES, REGULATIONS. AND FHA/VA MPS 2 CONTRACTOR SHALL VERFY ALL CONDITIONS AND DM349CM AT SITE BEFORE BEG" 4G CONSTRUCTION ANY DISCREPANCIES SHALL BE REPORTED TO FRANK BETZ ASSOOATES, NC. FOR JUSTFICATKOM AND /OR CORRECTION BEFORE PROCEEDING WITH WORK CONTRACTORS SHALL ASSUIvE RESPONSIBILITY FOR ERRORS THAT ARE NOT REPORTED. 3, ALL DINENSONS SHOULD BE READ OR CALCULATED AND NEVER SCALED. 4. ALL FOOTINGS TO BE BELOW FROST LINE (SEE LOCAL CODE) AND MUST REST CAN UNDISTURBED SOIL CAPABLE OF HANDLING THE BMDNG. • CONStLT LOCAL ENGIEER FOR PROPER FOOTING AND RBNFORCING SIZES S CONTRACTOR SHALL INSURE COMPATIBILITY OF THE BUILDING WITH ALL SITE REQUIREMENTS 6. IF BACKFLL EXCEEDS 4' AGAINST ANY FOUNDATION WALL. REINFORCE AS PER CODE. 7. ALL FOUNDATION AND STRUCTURAL MEMBERS SNIOULD BE VERIFIED AND STAMPED BY AN ENGINEER IN THE STATE WHERE CONSTRUCTION IS OCCURNG DUE TO A WIDE VARIANCE N LOCAL CODES SOU.. BEARING CONDITIONS. FROST LINE DEPTH. GEOLOGICAL AND WEATHER CONDITIONS. ETC. THE CONTRACTOR IS RESPONSIBLE FOR ADJUSTING AND VERIFYING ALL STRUCTURAL DETAILS AND CONDITIONS TO MEET ALL LOCAL CODES AND TO INSURE A QUALITY AND SAFE STRUCTURE- ALL WOOD. CONCRETE. AND STEEL STRUCTURAL MEMBERS SHALL BE OF A GOOD GRADE AND QUALITY AND MEET ALL NATIONAL. STATE. AND LOCAL BUILDING CODES WHERE APPLICABLE, 9. ALL COLUM S OR SOLID FRAMNG SHOULD BE DESIGNED TO CARRY LOADS AND SHOULD EXTEND DOWN THRU THE LEVELS BELOW AND TERMINATE AT THE BASEMENT FLOOR OR AT OTHER BEARING POINTS DESIGNED TO CARRY THE LOAD. 1O b FRA BETZ ASSOCIATES, INC. ASSUKES NO LIABILITY 5�� NC FOR ANY CHANGES OR MODIFICATIONS MADE TO THESE � PLANS BY OTHERS. L3 SOUTARE FOOTAGE FIRS T FL OOR 74iAA-60- FT. SECOVID FL OOP = c M" SO. FT. TOTAL 2640 SO. FT OIPT. FPS FLOOR 243 SO. FT. TOTAL ,30'4 SO. FT. REVISIONS I DA7 1h ,s drawing is not to be r or used to contract any bL without the written authority Frank Betz Associates, Inc. Z Q x O O J VNNI LL- LL- 0 Z 1 II w U O i t w 1 PL4 W BY: wma CK DATE: 9 -22-95 SHEET: OF: 6