HomeMy WebLinkAbout1418.97.336" PREFAB F.P
W/ HEARTH AND �:
5URROUND PEg
AL CODE
MDR Af IREPLACE PLACE OPTION
I/4" - 0°
0
0
8' -411
3660 k �`
3660
3660
14'-1"
8' -40 13i_1u
01011.
C-4
11 1, 01 5' -00
M
0
181 -411 — 6' -011
— — — — — — — — — — — — — — — --
� I
� v ;
C)
MDR
8b" CLG
CARPET
VAULTED GLG -
OPTIONAL d I
� I
I
54'-0"
I
M6R GARDEN BATH OPTION
1/4" - 11-0"
4812
°i
4/0 BP
4'-0°
' -0" 6' -311
2/6
2868 C/0
2/8 TILE
- E (ATTIC !
r, ACCE55 '
�I �L_�
m
01=
N I of I 42" HIGH
oll KNEEWALL
56E DETAIL
PER SPEC -
II o _
5' -3 1/2"
2/8
2/8
0
N I 11
= I Ilo
5'-10"
3660
E
DR r,
8'-0" GLG. CD
CARPET N
IRIS
7' -I I/2 "�
�
w
°C
15
to �_ ��
=
o
BOXOUT FOR FAU
v
2' I"
- -'-
j
r
o�
`V
I
14
4/0 BF'
FLU - FIELD
N
NOTES
VERIFY 51Z
3'-7 I/2"
13
5LAB FOUNDATION
1 /2" 6YP BD
7
12
ONLY
5/0 BP
HOLD HEADER TIGHT TO PLATE
w
o
ON 1/2" 5HEATH'6
,
2/8
I
8' -0" GL6.
\
ON 2x4 FRM'6
a°_
/
5'-10"
3660
E
IR15
2x6 °
2/6 IRIS WALL °
4/0 BP
20' -4 1/2"
DR r,
8'-0" GLG. CD
CARPET N
7' -I I/2 "�
�
w
°C
I
to �_ ��
=
o
�
v
2' I"
- -'-
j
r
o�
4/0 BF'
IR15
2x6 °
2/6 IRIS WALL °
4/0 BP
20' -4 1/2"
7' -I I/2 "�
2/8
to �_ ��
6' 9 I/2"
3'-4"
2' I"
5' I"
j
NOTES
3'-7 I/2"
I
I ALL CA5EO OPENIN65 GREATER THAN 48" WIDE
7
DR 3
HOLD HEADER TIGHT TO PLATE
w
o
DR 4
8' -0" GL6.
2. ALL BI-FOLD 00OR5 R.O.'5 = 1 1/2" WIDER THAN DOORS
0
8' 0" GL6
5
`"
CARPET N
HEADER HT. = 82" AFF
g
N
CARPET
3 ALL B 1-PA55 DOOR5 R.O.'S = SAME A5 DOOR
`"
HEADER HT - 83" AFF
4. 2x BLOCKING UNDER ALL EXTERIOR 5WIN6 DOORS
i
5. Ix BLOCK IN6 UNDER ALL EXTERIOR 5L IDIN6 DOOR5
111-0 1 /2",
101-4"
6 TOWEL. BAR5 (TB) OVER CA13INET5 AND TOILETS
--
-�
BLOCK IN6 TO BE 55" AFF TO CL
I
REF ELEV.5
7. TOWEL BAR5 (TB) NOT OVER GAB (NETS AND TOILET5
j
—
BLOCK IN6 TO BE 48" AFF TO CL
8, BLOCK IN6 FOR T155UE HOLDER5 (TH) TO BE 24" AFF
REF ELEV 5
REF ELEV.5
NOTE 1 ALL 12IMEN51ON5 ARE FROM FACE OF STUD TO
FACE OF STUD. ALL 5TUD5 ARE 3 1/2" UNLESS NOTED.
ALL DIMEN514N5 PRESENTED HERE ARE FRAME
DIMENSIONS ONLY - SEE SHT. 1.1 FOR FOUNDATION
FOOTPRINT.
11'-7 1/2"
10'-71/21'
11'-4 1/2"
REVIEW ALL WINDOW HDR 1-1E16HT5 PER PLATE HT. AND
--
VERIFY W/ ELEVATIONS AND CORNICE DETAILS
5E60NO FLOOR PLAN
NOTE
CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
ARCHITECT, IN WRITING, AND WRITTEN INSTRUCTION SHALL
/4i� ( -O,i
ALL PIMEN50NS AFFE6TIN6 CONTRA6TOR'5 PRODUCT5.
BE OBTAINED PRIOR TO PROCEEDING WITH c,ON5TRUGTION.
IN51ALLATION5 OR FABRICATIONS IN THE FIELD PRIOR TO
THE CONTRACTOR SHALL M WLD RE5PON5113LE FOR ANY
EXPEDITING THE CONSTRUCTION OF SUCH WORK.
ERRORS, 12156REPANCIE5 OR OM15SIONS FOR WH4:.H THE
ERRORS AND OMI5SION5 WHICH MAY OCCUR IN THE CONTRACT
CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOP
DOCUMENTS SHALL BE 13ROU6HT TO THE ATTENTION OF THE
TO CONSTRUCTION AND /OR FABRICATION OF THE WORK
4
0
N
N
N
M
N
G. M IG4-fAEL
WAN60UR
Architects / Consultants
1365 Shenandoah
Rochester Hib,
Michigan 48306
(248) 656-1181
PULTE
Master Builder
Project
I N 9 1 A N A
D IV 15 ION
11711 North Pennsylvania
Suite X190
Carmel, Indiana 46032
5ubdivi5ion / plan
KE55LER
Job No.
2555
Date
ISSUE 10/30/97
Sheet Title
5ECOND
FLOOR
PLAN
AND
OPT ION5
eel Nu.
2.2
5HT of