Loading...
HomeMy WebLinkAbout1418.97.336" PREFAB F.P W/ HEARTH AND �: 5URROUND PEg AL CODE MDR Af IREPLACE PLACE OPTION I/4" - 0° 0 0 8' -411 3660 k �` 3660 3660 14'-1" 8' -40 13i_1u 01011. C-4 11 1, 01 5' -00 M 0 181 -411 — 6' -011 — — — — — — — — — — — — — — — -- � I � v ; C) MDR 8b" CLG CARPET VAULTED GLG - OPTIONAL d I � I I 54'-0" I M6R GARDEN BATH OPTION 1/4" - 11-0" 4812 °i 4/0 BP 4'-0° ' -0" 6' -311 2/6 2868 C/0 2/8 TILE - E (ATTIC ! r, ACCE55 ' �I �L_� m 01= N I of I 42" HIGH oll KNEEWALL 56E DETAIL PER SPEC - II o _ 5' -3 1/2" 2/8 2/8 0 N I 11 = I Ilo 5'-10" 3660 E DR r, 8'-0" GLG. CD CARPET N IRIS 7' -I I/2 "� � w °C 15 to �_ �� = o BOXOUT FOR FAU v 2' I" - -'- j r o� `V I 14 4/0 BF' FLU - FIELD N NOTES VERIFY 51Z 3'-7 I/2" 13 5LAB FOUNDATION 1 /2" 6YP BD 7 12 ONLY 5/0 BP HOLD HEADER TIGHT TO PLATE w o ON 1/2" 5HEATH'6 , 2/8 I 8' -0" GL6. \ ON 2x4 FRM'6 a°_ / 5'-10" 3660 E IR15 2x6 ° 2/6 IRIS WALL ° 4/0 BP 20' -4 1/2" DR r, 8'-0" GLG. CD CARPET N 7' -I I/2 "� � w °C I to �_ �� = o � v 2' I" - -'- j r o� 4/0 BF' IR15 2x6 ° 2/6 IRIS WALL ° 4/0 BP 20' -4 1/2" 7' -I I/2 "� 2/8 to �_ �� 6' 9 I/2" 3'-4" 2' I" 5' I" j NOTES 3'-7 I/2" I I ALL CA5EO OPENIN65 GREATER THAN 48" WIDE 7 DR 3 HOLD HEADER TIGHT TO PLATE w o DR 4 8' -0" GL6. 2. ALL BI-FOLD 00OR5 R.O.'5 = 1 1/2" WIDER THAN DOORS 0 8' 0" GL6 5 `" CARPET N HEADER HT. = 82" AFF g N CARPET 3 ALL B 1-PA55 DOOR5 R.O.'S = SAME A5 DOOR `" HEADER HT - 83" AFF 4. 2x BLOCKING UNDER ALL EXTERIOR 5WIN6 DOORS i 5. Ix BLOCK IN6 UNDER ALL EXTERIOR 5L IDIN6 DOOR5 111-0 1 /2", 101-4" 6 TOWEL. BAR5 (TB) OVER CA13INET5 AND TOILETS -- -� BLOCK IN6 TO BE 55" AFF TO CL I REF ELEV.5 7. TOWEL BAR5 (TB) NOT OVER GAB (NETS AND TOILET5 j — BLOCK IN6 TO BE 48" AFF TO CL 8, BLOCK IN6 FOR T155UE HOLDER5 (TH) TO BE 24" AFF REF ELEV 5 REF ELEV.5 NOTE 1 ALL 12IMEN51ON5 ARE FROM FACE OF STUD TO FACE OF STUD. ALL 5TUD5 ARE 3 1/2" UNLESS NOTED. ALL DIMEN514N5 PRESENTED HERE ARE FRAME DIMENSIONS ONLY - SEE SHT. 1.1 FOR FOUNDATION FOOTPRINT. 11'-7 1/2" 10'-71/21' 11'-4 1/2" REVIEW ALL WINDOW HDR 1-1E16HT5 PER PLATE HT. AND -- VERIFY W/ ELEVATIONS AND CORNICE DETAILS 5E60NO FLOOR PLAN NOTE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ARCHITECT, IN WRITING, AND WRITTEN INSTRUCTION SHALL /4i� ( -O,i ALL PIMEN50NS AFFE6TIN6 CONTRA6TOR'5 PRODUCT5. BE OBTAINED PRIOR TO PROCEEDING WITH c,ON5TRUGTION. IN51ALLATION5 OR FABRICATIONS IN THE FIELD PRIOR TO THE CONTRACTOR SHALL M WLD RE5PON5113LE FOR ANY EXPEDITING THE CONSTRUCTION OF SUCH WORK. ERRORS, 12156REPANCIE5 OR OM15SIONS FOR WH4:.H THE ERRORS AND OMI5SION5 WHICH MAY OCCUR IN THE CONTRACT CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOP DOCUMENTS SHALL BE 13ROU6HT TO THE ATTENTION OF THE TO CONSTRUCTION AND /OR FABRICATION OF THE WORK 4 0 N N N M N G. M IG4-fAEL WAN60UR Architects / Consultants 1365 Shenandoah Rochester Hib, Michigan 48306 (248) 656-1181 PULTE Master Builder Project I N 9 1 A N A D IV 15 ION 11711 North Pennsylvania Suite X190 Carmel, Indiana 46032 5ubdivi5ion / plan KE55LER Job No. 2555 Date ISSUE 10/30/97 Sheet Title 5ECOND FLOOR PLAN AND OPT ION5 eel Nu. 2.2 5HT of