HomeMy WebLinkAbout12070084.41114
IF=
U
=I
on
►I r
IN
i
6 5 4 3 2
12'- 1 1/4" I I =
II
0
II
T II I
II I
I
I
IR
11 II �♦ �. 79
rq 87 r—
L J 11_ J I I
L7 -
�I II II
8' - 4„
I
a0
Lr) I
/ I
II
I I REMOVE EXISTING CLG.
UP TO LOCATION OF
NEW BALLROOM WALL
I
II I
II i
I II
II �
II
II
II
II I
'I II
ii
II I
II I
II I
27' -0°
I
II I
i ,doo� �04
3' -4"
6A DEMOLITION PLAN
1/4" = 1'-0"
I I
Z)
1�
General Demolition Notes
1. Contractor shall field -verify all existing conditions, dimensions, and arrangements.
2. Contractor is responsible for protection of all existing surfaces, materials, and
components to remain or be relocated. Damage to these resulting from performance
of Work shall be repaired by Contractor to satisfaction of Owner and Architect at no
additional expense to Owner.
3. Contractor shall provide temporary dust protection as required to prevent
construction debris and dust from migrating out of Project Area. Owner /Architect shall
confirm all dust prevention measures/locations and shall determine changes to these
measures.
4. All existing equipment and fixtures shall remain property of Owner. All reusable items
salvaged during demolition operations shall be retained for Owner's inspection. Only
items so inspected and rejected by Owner shall be disposed. All other such items
shall be turned over to Owner for disposition.
5. All existing surfaces located adjacent to, or exposed by demolition work and
scheduled to receive new construction shall be patched and repaired as required to
cleanly receive new work.
6. All existing surfaces located adjacent to, or exposed by demolition work and
scheduled to remain exposed after completion of new const. shall be repaired and
patched as required to receive new finishes.
7. Owner will be responsible for removal /rearrangement of all existing loose furnishings
during construction, unless noted otherwise.
8. Refer to Mech. /Elec. Drawings for additional patching and preparation work related to
M.E.P. demolition items.
9. Existing sleeves, holes, and other penetrations or new damage of existing building
structure above grade exposed by demolition and removal of piping, appurtenances,
equipment shall be patched and repaired as part of the Work. Maintain fire ratings of
all and adjacent construction affected.
10. Cap all piping to remain or abandoned in accordance with requirements of authority
having jurisdiction and in accordance with all local and state plumbing and health
codes. Utilize only pre- manufactured and approved fittings to cap existing piping.
11. Each Contractor is responsible for all demolition work required or noted for installation
of new Work. Demolition may include associated distribution systems, appurtenances,
equipment supporting controls, and miscellaneous supports, unless noted otherwise.
12. Coordinate all demolition with Project sequencing as directed by General Contractor
or Construction Manager.
�r
it
�r
I
14
C
SCHMIDT
A SSOCIATES
Architecture
Engineering
Technology
Interior Design
Landscape Architecture
Project No. 2012-007.000
Project Date 05.15.2012
Produced Designer Author
Se,
G1 ST f F�
i N0
32631
STATE OF j
Q`'' :ND ANP•
cH ITti;So
These Drawings and Specifications, and all copies
thereof are and shall remain the property and copyright of
the Architect. They shall be used only with respect to this
Project and are not to be used on any other Project or
Work without prior written permission from the Architect.
# Revision Date
111 Medical Drive
Carmel, IN 46032
KEY PLAN Z
Daniel and Judy
Corsaro
Aurelia Dance Studio
DEMOLITION PLAN
A -100