Loading...
HomeMy WebLinkAbout12070084.5140 C [y■ •m Lis 5 4 3 0- REFLECTED CEILING PLAN W v 1/8" = 1 - -0" - Office 64 SF I I Locker Room 79 SF 4' _ 0" 1 _ fi I t TI �I 104 r Locker Room 79 SF r i - A Floor Plan 1/4.. = 1' -0" 20'- 1 15/16" Reception 441 SF 100' - 0" 109 i II ;I II IT- 11 7/8" i )O 'I I V hen Ballroom SF 3485 SF / 111 r O �0 9' -1 Storage 52 SF Ir I I I Office 76 SF lil4 �o I i 114 0- 2 REFLECTED CEILING PLAN it i j j LEGEND Office 64 SF I I Locker Room 79 SF 4' _ 0" 1 _ fi I t TI �I 104 r Locker Room 79 SF r i - A Floor Plan 1/4.. = 1' -0" 20'- 1 15/16" Reception 441 SF 100' - 0" 109 i II ;I II IT- 11 7/8" i )O 'I I V hen Ballroom SF 3485 SF / 111 r O �0 9' -1 Storage 52 SF Ir I I I Office 76 SF lil4 �o I i 114 0- 2 REFLECTED CEILING PLAN LEGEND APC 2' X 2' Acoustical Panel Ceiling Light Fixture (Reference E- Series Dwgs) j PLAN NOTE DESIGNATION WHEELCHAIR CLEARANCE RADIUS OP P (09 51 13) 1t Door Number Exit Light � DOOR NUMBER Return Air (Reference E- Series Dwgs) r (Reference M -Series Dwgs) I Recessed Light Fixture 1t FURNITURE FM Suspended Fixture in Areas with Exposed Ceilings C COLUMN DESIGNATION Supply Air (Reference M -Series Dwgs) 17 (Reference E- Series Dwgs) 115 D� 1 General Plan Notes 1. All dimensions shown are to face of stud or masonry, unless noted otherwise. Dimensions designated as "CLR or "clear" indicate a clear dimension from face of finish to face of finish. Dimensions of exterior walls are to outside edge of foundation. 2. Dimensions for all openings for Mechanical, Plumbing, Fire Protection and Electrical shall be fire stopped at each floor penetration. 3. Provide bracing and blocking as required in walls supporting casework, tackboards, markerboards, and restroom accessories. 4. All door frames are located 4" from adjacent wall, unless noted otherwise. 5. All exposed outside corners of CMU shall be bullnosed. 6. Seal all joints between dissimilar materials. 7. All gypsum wallboard is 5/8" Type "X ", unless noted otherwise. 8. Where new floors meet existing floors, a smooth, straight, and flush transition shall be constructed. Verify in field existing floor elevations and conditions where a new floor shall be constructed adjacent. Trim and patch existing floor as required to achieve desired transition. 9. All exterior windows are Type "XXX ", unless noted otherwise. 10. Base elevation is 0' -0" = XXX.X' (United States Geological Survey data). 11. Hatching within walls shown in plans and sections indicates new construction. Reference Symbols TITLE MARK r','1ViewN�ame / 1/8" = V -0" SECTION MARK I ELEVATION MARK CUT LINE Sim DETAIL MARKt i j PLAN NOTE DESIGNATION WHEELCHAIR CLEARANCE RADIUS OP P WALL DESIGNATION 1t Door Number Frame Type DOOR NUMBER c r Door Label Door Type WINDOW NUMBER 1t FURNITURE FM FB COLUMN DESIGNATION NORTH ARROW N ROOM TAG Room name 101 UNIT MATCHLINE UNIT A UNIT B DEMOLITION NOTE /— 1 I REVISION TAG 0 DATUM POINT 6 5 4 3 2 1 014 ON ON MIA ■I.1 SCHMIDT A SS0CIATEs' Architecture Engineering Technology Interior Design Landscape Architecture Project No. 2012- 007.000 Project Date 05.15.2012 PmAircri Desianer Author S S� �Q G1 STe4�'- ' P i No`` 32631 1 is STATE OF �H G . /r.._ C^W�4 dd!� 00W=MMh'-% -These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. # Revision Date 111 Medical Drive Carmel, IN 46032 KEY PLAN z Daniel and Judy Corsaro Aurelia Dance Studio FLOOR PLAN A -101