HomeMy WebLinkAbout0601.97.3Jw
i
N
/
2-GAR 51PE
ENTRY GARAGE
1 /41' -- 11 -0"
1
54'-011
71 -8 1/2" 46'-3 1/2"
6'•5"
LEAD WALL PAST — — — —
OVER DIG 1101 / 1101 15/12 STEEL WINDOW
32" x 12" R.O.
—- I — VERIFY SUMP
LOCATION W/
I I I 8" POURED GONG WALL Lo SUMP I SUPER INTENDANT
u Ir n u n
w W/ 4x12 BRICK LEDGE
11 n n u n u 8'-0" POURED HT ON
" 2,0" '�' L � BLEEDER 1111 1 �1
t o of w it It = 11 11 8 x 20 CONT. SPREAD � o 0
— t BL 2x10'5 FOOTING
PC t o o "' I UNDER KITCHEN / NOOK vo
W
Il20
1112 N 4�A5E MENT N FAU
I— G _^ " I I I DU6HIN3PIPE
L 4 COMP. 5AND FILL ( FOR RADON EXHAUST
PL FLUE 1 W/ "T" BELOW SLAB
— — — — — wsxlo ( 1 36" x 36" x 16" CONC. PAD FOOTING
�11 u ® — J ROUGH IN 1 1/2" PIPE
111 1 BLEEDER L-- —J W/ 3 PIA STL. COL. CENTERE
I TO FLOOR DRAIN FOR
_ p FAU CONDEN5ATE
o ANT TO STAIR
74 1/2" 1214" I I' 3" 11'-0 1/2" 111-8"
r— 3'-11/2" 41-611 6YWAMPOGKET
o - - - I . T . 511 DEEP -moo
cl� +� i t 1 I I r° i T W8x18 .I W8x18 I 6" HIGH C^ ~NOTE
`� z I
cD 7,0
X I L_ ' I FIELD VERIFY
4-- o °
Q UTILITY LOCATIONS
WSx1a I " x 16" CONC M ' ( I FOR SIDE OF HOUSE
ak
_ 1 _ _ I— — ° FT6 BELOW 3 W/ SUPER INTENDANT
I v °
__J EQ a X v v o ED g
3
-J C>
Lu
:z
- >
N o I o 7 BEARING WALL o n
X U
- -- - PG- _
1 I C 9 j PG oo ,f, M
BLEEDEf#11 1 1�1
( I �
I BLEEDER I (
20'-0 I/2° - - - 1 33'-11 1/2" uJ
WATER AIIV SEWER
en
ENTRANC LOCATION
I L
—�— -
-- = NOTE: I I
LEAD WALL PAST PROVIDE (2) #4 REB4R, TEN FT.
OVER DIG cA
LONG TO SFIAN UTILI� Y TRENC
I I
2' -2 1/2"
161-311
21141
FOUNDATION PLAN AT 5A5EMENT OPTION
1/411 ; 11.011
2'-6 1/2"
101.3 1/2"
SEE ELEVATIONS FOR
FOUNDATION LAYOUT
IN THIS AREA.
t
22'-8 1/91"
Field verify all dimensions
DO NOT SCALE DRA WINGS!
NOTE:
SOME CCItUM9CDIMEN510N5 ARE FROM CENTER OF COLUMN
TO EXTERIOR FACE OF BASEMENT WALL.
NOTE:
ERRORS AND OM15510N5 WHICH MAY OCCUR IN THE CONTRACT
DOCUMENTS SHALL Be BROUGHT TO THE ATTENTION OF THE
ARCHITECT, IN WRITW, AND WRITTEN INSTRUCTION SHALL
BE OBTAINED PRIOR TO PROCEEDING WITH CONSTRUCTION.
THE CONTRACTOR SHALL BE HELD RE51PON5OLE FOR ANY
ERRORS, 019CREPANCIE5 OR OMIS5ION5 FOR WHICH THE
GONJRAGTOR FAILED TO WTIFY THE ARCHITECT PRIOR
TO(CON5TRUGTION AND /OR FABRICATION OF THE M.
N
Gopyr-igtit 1945 a#e Hone Gorporatlin
I
G. M ICHAF:7L.
WANGOUR
Architects / Consultants
1365 Shenandoah
Rochester Wls
Michigan 48306
(810) 656-1181
Project
INDIANA
D IV 15 ION
12220 North Merman 5t.
Suite 1185
Carmel, Indiana 46032
Subdivision / Plan
LAFAYETTE
Job No.
LAFAYETTE
Date
155UE 11/02/95
REV 1 12/8/95
FOUNDATION
PLAN
FULL
WEMENT
OPTION
Sheet 40.
1.3
5HT of