SUPERVISOR WORKSHEET I .I_1yLANp
BASEMENT
PROJECT INFORMATION
HOUSE NAME / ELEV.
SET NUMBER
PLAN / JOB NUMBER
STANDARD OR REVERSED
ANY NON -STD. CHANGES?
FOUNDATION CHECKLIST
SLAB
PROJECT INFORMATION
HOUSE NAME / ELEV.
SET NUMBER
PLAN / JOB NUMBER
STANDARD OR REVERSED
ANY NON -STD. CHANGES?
FRONT OR SIDE LOAD I FRONT OR SIDE LOAD
STD., ENLARGED, OR FULL BSMT.
(IN SET ") (OPT. 293) (OPT 295)
ALL SIDING OR BRICK FRONT
(IN SET -M) (OPT. 490)
BSMT. WINDOW OPT. QTY.
(MARK LOCATIONS) ON PRINT
FRONT PORCH WALL HT. TO BE
ABOVE TOP OF FTN. WALL
FLUSH W/ 9 1/4" fist FLR TJ.I.'s 2" ABOVE W/ 11 1/8" let FLR TJ.I.'s 6" ABOVE W/ 14" let FLR T.J.i.'s
MASONRY
FIREPLACE OPT. PRE -FAB
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
BUILDING PERMIT NUMBER
LOT ADDRESS
TOWNSHIP
CHECKLIST
SUMP PUMP LOCATION MARKED SEWER AND WATER SLEEVE
SUMP PUMP SLEEVE LOCATION MARKED LOCATIONS MARKED (3' W/ 4" SEWER
COUPLER, 5'W/ 1 1/2" SLEEVE)
MARK OUT ALL HAUNCHE5 NOT USED HIGHLIGHT ALL BEAM POCKETS
MARK M FRONT PORCH WALL HIGHLIGHT ALL PAD FTG. LOCATIONS
IF NOT ON PRINTS
BEAM TAKE -OFF SHEET COMPLTE AND TURNED IN
TO FOUNDATION SUPERVISOR
(TO BE COMPLTED EVEN IF NO BEAMS REQUIRED)
ALL SIDING OR BRICK FRONT
(IN SET ") (OPT. 490)
MASONRY
FIREPLACE OPT, PRE -FAB
NOTE- INSTALL BRICK LEDGE ON MASONRY FIREPLACES
BUILDING PERMIT NUMBER
LOT ADDRESS
TOWNSHIP
CHECKLIST
MARK OUT ALL HAUNCHES NOT USED
MARK IN FRONT PORCH WALLS IF NOT ON PRINTS
WATER SLEEVE LOCATION MARKED
HIGHLIGHT ALL THICKENED SLAB FOOTINGS
HIGHLIGHT ALL PAD FOOTING LOCATIONS
BEAM TAKE -OFF SHEET COMPLTE AND TURNED IN
TO FOUNDATION SUPERVISOR
(TO BE COMPLTED EVEN IF NO BEAMS REQUIRED)
DO NOT REMOVE BLUEPRINTS FROM JOBSITE
I. EXCAVATOR PLACE PRINT TUBE INSIDE OF EXCAVATION.
2. WALL CONTRACTOR LEAVE ON TOP OF WALL.
3. PLUMBING CONTRACTOR LEAVE ON TOP OF WALL.
4. CONCRETE CONTRACTOR LEAVE ON TOP OF WALL.
FRAME PUNCH -OUT CHECK LIST
1. GARAGE
GARAGE DOOR OPENING FRAMED TO CORRECT SIZE- l' HT., 8' OR 16' WIDE.
GARAGE ATTIC ACCESS FRAMED TO CORRECT SIZE AND LOCATION.
NAILERS AT ALL CORNERS OF GARAGE AND CEILINCs_
GARAGE STEP FRAMED AND KICK PLATE UNDER DOOR
BOW STUDS
STRAP ANCHOR NAILED CORRECTLY
2. HOUSE
CHECK FOR BOW STUDS
CHECK FOR NAILERS
MARK DOOR SWING DIRECTION AND SIZE
CHECK FOR CA51NG ROOM (MIN 2" ON EACH SIDE)
CHECK CENTERLINE OF KITCHEN WINDOW
CHECK BULKHEAD DIMENSIONS (2" LONGER AND 2" WIDER THAN CABINETS)
CHECK WALL SIZES IN RELATION TO CABINET SPACE
CHECK VANITY SIZES IN RELATION TO WALL SPACE
CHECK VANITY DEPTH TO DOOR OPENING (MIN. 24 1/2 ")
CHECK DOOR OPERATION AND INSTALLATION
CHECK WINDOW OPERATION AND INSTALLATION
CHECK BASEMENT STAIR AND 2nd FLOOR STAIR INSTALLATION
PITCH RAIL WALL INSTALLED 1/2" BELOW STRINGER AND 1 1/2" SHORT
HALF -WALL 42" FROM FLOOR AND SAME PITCH AS STAIRS (BOTH STAIRWAYS)
HALF -WALL AT STAIRS PAST STRINGER 1 1/2"
TUB PLATFORM BUILT CORRECTLY 16 1/2" HT., 39" X 51" INSIDE
NO STUDS * 24" O.G. AT CERAMIC AREAS. (16" O .C. MAX.)
TUB BLOCKS INSTALLED AT CERAMIC AREAS.
NAILERS FOR FIBERGLASS TUBS INSTALLED
MEASURE VINYL AREAS FOR SQUARE
GB PANELS HAVE BLOCKS ON ENDS
CHECK FOR LOAD - BEARING POINTS IN HOUSE AND PROPER LOAD TRANSFER
STRAP ANCHORS SECURED IN HOUSE
CRAWL SPACE AND BASEMENT CLEANED OUT
STAIRWAY SHIMMED (MAX. 1/2" GAP EACH SIDE)
let AND 2nd FLOORS LINE UP IN STAIR WELL
NO GAPS ABOVE STAIRWAY DRAFT5TOP
STAIRWAY DROP CEILING DONE CORRECTLY (CHECK PRINTS)
HANDRAIL BLOCKS INSTALLED 32" FROM STAIR N051NG
SAFETY BOOTS AND RAILS INSTALLED 3 1/2" FROM STRINGER
SQUASH BLOCKS INSTALLED PER PLAN AND TJ.1. DETAIL SHEET
FLOOR SHEATHING NAILED PER SPEC.'s
FALL PROTECTION INSTALLED AT STAIR WALL OPENINGS
EYEBOLT AND ANCHOR POINT IN PLACE
ALL DRAFT STOP INSTALLED ON CHASE AND BAND JOISTS
ALL TYVECK STAPLED IN -PLACE EXTERIOR
ALL HOLES PATCHED IN INSULATION BOARD
ALL TRIM INSTALLED PER PRINT
31/2" R ►P5 1/2 SHEATHING INSTALLED ON CORNERS
ALL WINDOWS TAPED ON TOP AND GLUED ON FOUR SIDES
ALL DOORS TAPED ABOVE
PRINT HUNG ON NAIL IN GARAGE
PERIMETER AND PANELS CLUED
INTERIOR WALLS GLUED DOWN
INTERIOR AND EXTERIOR WALLS MAILED INTO TRUSSES BELOW
SET TUBS INTO ROOM AND WIFE-OUT
ATTIC ACCESS INSTALLED IN HOUSE PER PRINT, 12" SIDES
ALL WINDOWS INSTALLED PER PRINT, ELEVATION AND STACK
JOIST HANGERS NAILED FRONT AND SIDES
SITE PICKED ,1P AND PUT IN PILE EACH DAY
2X4 AROUND TOP OF CHIMNEY, 1 112" PAST CHIMNEY FLAT
ALL GIRDER TRUSSES NAILED PER ENGINEERING
REVISEp 312"►;9�`