Loading...
HomeMy WebLinkAbout0982.97.103" V.T.R. I I t I r I I I I I I I 2 ""--m 1o_` � I / I r/' I I I ' I » I � 12- I I �I I I I I I ISO. 'A' NO SCALE -1' /s" 2 "---� 1 1 C.O. I I » RELOCATED 1" CW DOMESTIC SERVICE �- {� i 1" B.F.P. ! rN11 d 1 � II f ii (1 i 'I I 290 1� c II i PROVIDE 1. 1/20 VENT FOR ALL & (HUB DRAINS) l � I I' EXISTING BLDG. NF.W ADDITION 454 ' EXISTING 4" SANITARY SEWER } — ____.__ - "I' `�'_ —_ ___ -�-. _.- .__..,- _. :..�.,._ -... _. ,:v :. _- ._r- _. ................. .. __ ._ ._.. ___ .—.... ,- --- a'�'�•_ -' .._ - -'--t"'... , . _ - _. , _.. _--., -. a -.. __ _ -'r i � ; SEE ISO. A THIS DWG FOR - -_-__, 4 __.._ -..' - SAN & VENT LINE SIZES ! c�T, ' <` �. '— 11 } ill } CW - j - �' l I , /i » ♦ 3 I 2 4 y 5 i L J �i 2" i 7 �_� d i ), ""` .ate° -.. � �•� WH 42 VE T UP ' 4 !f i 2 I W /3" V.T.R. 1 /2" L �, I; �f >.0 �; { 9 - 02 10 ` I 3 , 4511' _ _ I HW 3/4--1 v v 1/21 i - I y; x + 455 \ , I 4 -- { 4„ = L1/2 i 'I ik ; ;;z.w �� .—' • ' _ ._ I C AM - -- -_.- .i-,.. -- 1 -I 374 (� 1 " DRAIN I 1 " 3" 2" DRAIN n — - --� ---- - - - - -- SAN---- &- - - - - -- = =-_—� - -- ------ - --1-0 C.O. I _ 1 -{ I :I HW 1 —__� �_ ,0 ,/2" D " RAIN CW rL ( j FW 1 D ' . . 1/2 I. - -1 i 4' t $ ! /''� ! }I _ �LT >�.i. I 590 2 _ --- _.___Y .,_ . * s ' �'r- i 0 O-� �, , { _ 580 r 57 . f 3/4 __� �. 'I! {' r I I _ __ _. _ __ ___ -__ _ - -___ -. _- ____.- .___ -__ . ___.__ _._.�. __- oo .'1/ 3/4" 6 'i 457 225 220 211 KITCHEN EQUIPMENT SCHEDULE NOTE: ITEMS LISTED IN THIS SCHEDULE ARE PROVIDED AND INSTALLED BY KITCHEN CONTRACTOR AND CONNECTED TO PLUMBING UTILITIES BY PLUMBING CONTRACTOR. 150 BAGEL OVEN: PROVIDE 1/2* FW CONNECTIONS & 3/4" NAT'L GAS (170 CFH), EXTEND TO ACTUAL CONNECTION POINTS INSIDE UNIT ITSELF. PROVIDE IW TO F.D., PROVIDE PRESS. REGULATOR, PRESS. GLIAGE, B.V., Y— STRAINER ON FW LINE AND BFP AS REQUIRED. 211 POST MIX: PROVIDE 1/2" FW (ROUGH —IN 44" A.F.F. W /ANGLE STOP. PROVIDE BFP IF REQUIRED BELOW CABINET, ROUTE UP THRU COUNTERTOP W /ESCUTCHEON. PROVIDE IW TO HUB DRAIN. 220 COFFEE BREWER: PROVIDE 1/2" FW (ROUGH —IN 44" A.F.F. W /ANGLE STOP). PROVIDE BFP AS REQUIRED. 225 ESPRESSO MACHINE: PROVIDE 1/2" FW (ROUGH —IN 44" A.F.F. W /ANGLE STOP). PROVIDE BFP AS REQUIRED. PROVIDE IW TO HUB DRAIN. 229 ICE MACHINE: PROVIDE IW TO HUB DRAIN. 290 BAG —IN —BOX: PROVIDE 1/2" FW (ROUGH —IN 90" A.F.F.). 374 PROOFER: PROVIDE 1/2" FW (ROUGH —IN 78" A.F.F.). PROVIDE IW TO F.D., PROVIDE B.V. AND Y— STRAINER ON FW LINE. PROVIDE BFP AS REQUIRED. 451 ONE COMPARTMENT SINK: PROVIDE 1/2" CW, HW (ROUGH —IN 8" ON CENTER O 12" A.F.F. W /ANGLE STOP). PROVIDE IW TO HUB DRAIN. 455 HAND SINK: PROVIDE 1/2" CW, HW (ROUGH —IN 4" ON CENTER O 12" A.F.F.). 1 1/2" VENTED WASTE (ROUGH —IN WALL O 24 1/2" A.F.F.). 457 HAND SINK: COUNTERTOP, PROVIDE 1/2" CW, HW (ROUGH —IN 4" ON CENTER O 12" A.F.F.). 1 1/2" VENTED WASTE (ROUGH —IN WALL O 32" A.F.F.), PROVIDE IW TO HUB DRAIN. 459 THREE COMPARTMENT SINK: PROVIDE 1/2" CW, HW (ROUGH —IN 8" ON CENTER O 12" A.F.F.). MANIFOLD 2" WASTE LINES TOGETHER TO CENTER COMPARTMENT AND PROVIDE IW TO HUB DRAIN. 494 DRIP PAN: PROVIDE IW TO HUB DRAIN. 502 ICE MACHINE: PROVIDE 1/2" FW (ROUGH —IN 72" A.F.F. W /B.V.). PROVIDE BFP IF REQUIRED. MANIFOLD IW CONNECTIONS TOGETHER TO F.D. 570 WALK —IN— COOLER: PROVIDE IW FROM EVAPORATOR TO F.D. 580 WALK —IN— FREEZER: PROVIDE IW FROM EVAPORATOR TO F.D. 590 WALK —IN— RETARDER: PROVIDE IW FROM EVAPORATOR TO F.D. PLUMBING FLOOR PLAN PLUMBING SCHEDULE & NOTES: .NOTE: ITEMS LISTED IN THIS SCHEDULE ARE PROVIDED AND INSTALLED BY PLUMBING CONTRACTOR. WATER FILTRATION: CUNO #4 —S -2H WATER FILTER SYSTEM W /FOUR HEAD MANIFOLD UTILIZING (1) #CFS8504 —B PREFILTER & (4) #CFS8112 —S QUICK CHANGE FILTER CARTRIDGES. 0 NEW FLOOR DRAIN, JR SMITH #2010 —A, THE OUTLET SHALL BE THE SAME SIZE AS THE SANITARY LINE SHOWN ON DWG., PROVIDE P —TRAP. O3 NEW HUB DRAIN, TOP RIM OF HUB TO 4" A.F.F., PROVIDE P —TRAP. 0 NEW LAVATORY, AMER. STD. #0355.012 W /DELTA FAUCET #2599 LGHGMHDF AND TRUEBRO INSULATION KIT. MOUNT LAV ® HDCP. HEIGHT. NL( MOP BASIN, FIAT MSB -2424 W /3" OULET AND #830 —AA SERVICE FAUCET W /VACUUM BREAKER AND HOSE BRACKET. O6 SCALE FILTER: SCALTROL #SC -50, UNIT MUST BE FITTED IN HORIZONTAL POSITION. DISPENSING OF SCALTROL SHOULD NOT EXCEED 50 PSI. (7 NEW WATER CLOSET, AMER. STD. #3043.102 W /REGAL #111 VACUUM BREAKER, 1" ANGLE CHECK STOP AND OLSONITE #95 OPEN SEAT LESS COVER. ® Na GAS WATER HEATER, A.O. SMITH #PGCG -50, 40,000 BTUH GAS INPUT, 43.1 GPH RECOVERY RATE ® 90 DEG. RISE. PROVIDE T &P RELIEF VALVE. WATER HEATER TO SET ON PLATFORM ABOVE MOP BASIN. �9 3/4 "x3/4 "x1" CW TEE, 3/4 CW UP TO WATER HEATER AND 3/4" CW DN. TO SUPPLY MOP BASIN AND LAV (BRANCH LINE SIZE TO BE 1/2" FOR BOTH FIXTURES). 10 6" PVC UNDERSLAB FOR SODA CONDUIT. 11 CAP & RELOCATE EXISTING 1" DOMESTIC CW SERVICE TO NF-W LOCATION IN BACK ROOM 108. 12 NEW GREASE INTERCEPTOR, J.R. SMITH #8004, 2" INLET & OUTLET. UNIT SETS ON FLOOR. 13 DEMO EXISTING 40 GALLON ELECTRIC WATER HEATER. 14 PROVIDE 3/4" CAPPED TEE & VALVE FOR HOT SHOTS TENANT. Li NORTH PROVIDE WATER FILTER AS— SPECIFIED ON PLANS MOUNTED ON WALL ABOVE BACKFLOW PREVENTER SUPPORT PIPE AS REQUIRED TEST PLUG FOR PRESSURE — GAGE, SUPPORT FROM WALL OR FLOOR 1 +7W COPPER WATER SERVICE QUICK CHANGE FILTERS (TYP.4) BACKFLOW PREVENTER FILTERED WATER SUPPLY AS SHOWN ON PLANS COLD WATER SUPPLY AS SHOWN ON PLANS SHUT —OFF VALVE BY —PASS BRONZE BODY, SCREWED CONNECTION, PRESSURE REDUCING VALVE, SET AT 75 PSI J GATE VALVE: BRONZE BODY, SCREWED RESILIENT SEATED, NRS. TYPICAL BALL VALVE: DO NOT USE QUARTER TURN VALVE BRONZE BODY, FULL PORT, SCREWED ENDS STRAINER: BRONZE BODY, SCREWED, STAINLESS STEEL SCREEN FLOOR WATER ENTRY & FILTER SYSTEM NO SCALE i z Z�� SCALE SCALE I oft" or a LRH P- w Q �--� Q Few W z Lo C V SCALE SCALE I oft" or a LRH P-