HomeMy WebLinkAbout0970.97.5ROUGH FRAMING NOTES:
1. USE (2) -2x4 CRIPPLES UNDER EACH END OF HEADER
FOR OPENINGS 8' -0" OR GREATER IN WIDTH
2. ALL FIREPLACE STACKS ARE TO BE AT A HEIGHT MEASURED HORIZONTALLY
FROM ROOF PLANE OF 10' -0" AND A MIN. OF 24" VERTICALY FROM THE
HORIZONTAL PLANE. (UNLESS NOTED OTHERWISE)
3. ALL BEAMS TO HAVE MINIMUM (2) -2x4 STUDS UNDER
EACH END FOR BEARING SUPPORT
4. ALL WALLS TO BE 20 STUDS AT 15" O.C. UNLESS
NOTED OTHERWISE
5. ALL WINDOWS TO HAVE DRIP CAP MATERIAL AT TOP
5. STANDARD HEADER HEIGHT TO BE AT 6' -10 7/8" A.F.F. (U.N.O.)
7. FINISH FLOOR REFERENCES ARE TO TOP OF DECKING FOR FIRST AND
SECOND FLOOR FRAMING AND TO TOP OF CONCRETE FLOOR FOR BASEMENTS
8. ALL SOLE PLATES UNDER BASEMENT WALLS TO BE TREATED WOOD
notes.FRMI
XX'.XX'
MAIN LEVEL FRAME PLAN
:poi.: va• = r -o'