Loading...
HomeMy WebLinkAbout1173.97.3-- 38' -2° t 35' -9 1/2" 3' -10' 3' -10" 5' -b �i° 24' -140 254° .�. 10' -1 '/2" I U ALL SOIL BASED ON 3000 P.S.I. CW2448 -1 ----------------- - - - - -- - - - -- 2) ALL CONCRETE MIN. 3000PS.1.026DAYS, / - - - -- - - - - - - - - -- - - 3) ALL FOOTINGS ARE 16' WIDE X 8' DEEP UNLE66 / J - - -- l NOTED WALL6 RWISE. 4) ALL WALLS ARE 8' THICK W1 BASEMENT WALL HT, AS ----------------------------------------- NOTED AND GARAGE/ CRAWL/ SLAB WALLS 1 Q 2'-8' HIGH UNLESS NOTED OTHERWISE, 5) AND JUD E FOR THEMSELYES� E BURABILITI' OF CONDITIONS THE PLANS IN RELATIONSHIP t0 THE BUILDING SITE. 1 1 i I 6) DRAWINGS SERVE AS A GUIDE TO THE CONSTRUCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - OF THE BUILD ING, AND IN NO WAY DICTATE ANY OF T14E I - LOCAL AND/ OR STATE BUILDING CODES, THEREFOR I i 15' -81,2. I ! 4 It IS THE CONTRACTORS RESPONSIBILITY TO REVIEW I i �0 ALL PLANS FOR ACCURACY AND CLARITY AND t0 I I INSURE THAT ALL SUBS ARE CLEAR AS TO THE SCOPE I i w I I OF THEIR WORK, WICKES LUMBER ASSUMES NO I I a 1 I RESPONSIBILITY FOR ERRORS OR OMISSIONS IN 1 1 9i DESIGN OR DIMENSIONS. i ! o l i /`'� °ry I ALL STRUCTURAL MEMBERS AND BEAMS ARE BASED w ON AN ASSUMED NEED, CONTRACTOR TO VERIFY BASEMENT LAYOUT I ACTUAL NEEDS AND SIZES IF NOT SHOWN. I i I 8) ALL DIMENSIONS ARE TO EDGE OF CONCRETE OR CENTER OF '71 1 8' X 9' POURED CONCRETE WALLS a 1 ♦ \ \ BEARING, FOR FINISHED DIMENSIONS, SEE SHEET 4 OF 1. � 95 m 4' CONC. SLAB ON $ �I iI 4' MIN. PEA FILL I LINTEL AT OVER DIG \\ 31 1 1 AS REQUIRED, ALL \ \ " I I I POCKETS BY WALL ♦ \ `\ uI I F GIRECTUWT FitA*W I i CONTRACTOR \ \ flRtrucE Maur uu RA16ED i I HEARN ! FACE MATERIAL I I A6 6P*CMM, I I 3' dla. STEEL 6" BEARING WALL W/ I I Q ♦ \ \ \ �' ��� ?, JACK POST ON THICKENED SLAB BY I I '�' \ ♦ �~ 36" X 36' X 18" CONCRETE CONTRACTOR. i I ♦ ♦ ♦ \ ; in t /r �) �, CONCRETE PAD 1 \ IS -- `�jL -- ----- - - - - -- - - - - 3_. -0__.J ♦ \ - - - - - - - - - - - - - - - - - - - - - - - - - -� i FiAC 4 I \ \ I �x 2' -3 �i' 19' -I �i' + h' -10 14" 8" ( I ♦ \ ♦ \ awl 1 / g i UNFINISHED MECHANICAL/ STORACsE Uzi I I --------------- - - - - -- - - -- // - ♦ \ — I T IQ 10° / 3'-Om — — — 2'-&* , S ♦ 4 \ ♦ b� /. - - - - - - - - - - - - - - - - - - - - - - / / ♦ \ iI I - - - -- -- - ----------- - - - - -- -- ',�' ' • , \ / J I1------ .---- - - - - -- -- -- - - - - - - - - - - - -- 1- - - - •� / I I 1 i'" 41 CONC, SLAB OVER i 'j i ► l 4' MIN GRAVEL FILL I I l J i- - - -• _ I I a+ - - - -_ I 1 c LINTEL AT OVER DIG STEP FOUNDATION AND FOOTING A I I ! 11 AS REQUIRED, ALL AS REQUIRED FOR WALK-OUT WALL 1 t � I I I _ J I ( 1 GONTRAGTORW � t I AS SHOWN, FRAMING AND — — — ' BRICK VENEER WHERE SHOWN �- — — — — — — —I ( 1 I ! FLOOR DRAINS AS SHOWN u I ! 0 FLOM DUN 1 I SLOPE FLOOR TO DRAIN II i I - -- - - - — — — — — — — — - - L---- - - — — — — •— ,/ ,/ r---- - - - - -- - - I 1 E$crwr+ 1 r -- -- - - - - -- -- ♦ __ o ,' ,' \ I I I I SLAB -`r I 1 `r \` ♦`♦ // // I I 1 1 4' CONC. SLAB OVER — — — — `� ♦ / 14" MIN. GRAVEL FILL ♦ ,' ,' ♦ \ / / ---------------- - - - - -- -- - - - - - - - - - \ ` , , A 14' -10" 10' -0' 13'-4' 8' -0' 2'-4' 15'-4° ♦ ♦ `♦ ,' ,' ♦ ♦ / / POURED CONC. WALL. FOUNDATION/ BASEMENT PLAN SCALE: 1/41 =1'-0" \ `♦ `�' , / s "x16' C,M,U, I FOOTER FOR BLACK WALL 8' CONC. LINTEL -- FOOTER FOR 9' CONCRETE WALL LINTEL DETAIL FOR BASEMENT SCALE: 1140 a 1'-0° Qi d {� 0 � •r _a ' U � e 0 IL �z �4 o�� e L W- 2� ot r ILA. tu EI LW pC�J O QDi u n K, I oo. FLr-Lq � C nn nn f�77 L�1 OL \ O n� u O (3-11 1J L�� \ c r; rc O b a I c c V Lr Z � C O y � b O � s � a r S:� cc W O� F :O~ .,M O ck DATE= 08. DRAWN BY: J.4( SCALE: I AS REVISIONS= SWEET