HomeMy WebLinkAbout1183.97.4O
C4I
33' -0"
6'/4"
H'
CW4464 -3
2 BOTTOM TO BE 30' ARE,
I I I I
I I I I
2' -0" 12' -0' 1 I
I 4 1
I I I`T�sr�_$uiiE I I
If TRAY CLG. 1 1
1 I 1 I
I } -- — — — — — — — — — — — --
I
1c-------- - - - - -- -2
13' -1 IV 3'-4'
2'-4'
8' -3 34"
SEGMENT UNITS, SEE ELEV,
CW 2464/4864P /2464
— r I
2 -STORY 2X6 STUD WALL
I
SPACE POR MT4N
ENMTAM"ff WT
"DID DNlECT VENT um
on NEARTN AS SPECpw
0 '/2"
+
in
G AT OO-1 4
14' FLAT CLG, °',
_ {'
u+rt .
3-0 V3' 114
u I tP VAULTED CLG, r-I' A 3''4' t.`q
I _ 14' CL_G.
nx4a• uat - - CLG - -
PuNT L��! ABOVE
A \ /+ Sri °D I UP
at
r.' aFavea cri
2'-4" I
I .
I6'-4 V2'
i I b'4'
I
I
I 9' CLG. I S' CLG.
I I
4� cW
3'-b" 3' -2" 5'-4"
CW2464 -2
3' -0"
ENTRANa
If 2 -STORY
^' I I iLn
I!
3r•xa0' DOOR
v1" 0 ��J
i
■ 3'�:;
i
0
J,
3''L"
3'-8"
1'-4"
.Q
4
2'-6" 2'-0
DECK AREA
26,$„
16'-4"
3'-6 '/a" 1'41 "Van .
i 6' -0" SLIDING
HOQK
9' CLG.
Rl" BEAM AS RNORED
.1'-&'/2' 1'-301
I!
�II
a l l
�11=
114
O1I"�
t�i I I
wli
OII
9' CLG.
Y
9' CLG.
J
4
12' -10'
'^ S' CLCs.
— — BAR LEDGE
v
—� PAS
Elmer
r oil -
G
2' -0"
8'
Jill
�p 1
4
-on
. i LAUNDRY �
DOWN
-3' -0' 9 CLG.
STL,
CHA,$E
r
i
I
i
KIISH BEAM AS R62MED
4
CWP-1664
I i
I i
4'-O"
i j I
2' -9 3/4" 2' -0" 2'-0 2' -0" 12' -2'4
2'-4" i
a
:::a
3' -1 I'2"
9' CLG.
Is
2X6 STUD WALL
14 "TJ1356P JOIST OVER GARAGE
aD
3
i-- cow, STOOP
�I
4� 4
4
v
I
i
i
cq !
r
I
LE
FliI _ ,
�I QI
� I 'n'
4 I
XI �
I
o,
I
�I
�I
i
j+
j
�j
4 jfl - - - - - --
1
CW24I64 -3
3/4" 6' -2 1/4" i _ If-o" -- �F�- -- Ilt-0 - - -- - - - --
13' -0" 22 -0" — -- - -- - - --�
MAIN FLOOR LAYOUT niN S.F.
SCALE= 1/4"- 1' -0"
NOTES:
1) THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND JUDGE
FOR THEMSELVES THE SWA15LITY OF THE PLANS IN
RELATIONSHIP TO THE BUILDNG WE
2) DRAWINGS SERVE AS A GUIDE TO THE CONSTRUCTION OF THE
BWLDMG AND M NO WAY DICTATE ANY OF THE LOCAL AND/ OR
STATE BUILDING CODES, THEREFOR IT IS T4E CONTRACTORS
RESPONSIBILITY TO REVIEW ALL PLANS FOR ACCURACY AND
CLARITY. HOLLEY 4 ASSOCIATES A86U?M NO RESPONSIBILITY FOR
ERRORS M DEMN DIMENSIONS OR OMIS610N6,
3) ALL STRUCTURAL MEMBERS SWOVN ARE BASED ON AN
A88UMED NEED, CONTRACTOR TO VERIFY ACTUAL NEED
AND SIZES IF NOT SHOWN.
4) ALL WINDOW SIZES LISTED ARE AS MANUFACTURED BY
SEMCO WOOD PRODUCTS W/ FINISH TO BE
DECIDED BY OWNIBR,
5) ALL WALLS 11 BRICK ARE Wi w 3 W STUD AND 4' BRICK,
WHILE ALL OTWE R WALLS ARE 3-V2' U,NA.
b) CEILING HEIGHTS ARE AS NOTED ON FIRST FLOOR AND 8' -0 SECOND
FLOOR W/ SECOND FLOOR HALLWAY B 9'-0
0
VV
O
4
�n
u-
Q
Z
Q
�
CQ
LU
r—ji
Z
U
0°
O
0
O
4
O
Q
Z
Q
�
CQ
LU
�
U
0°
a
DATE: 09
DRAWN BY= J,N
SCALE= A6
REVISIONS=