OPEN OFFICE AREA
REFLECTED CEILING PLAN
SCALE: 1/8' = 1. -0'
NORTH
OPEN OFFICE AND 8WITCHBO/UiD OPERATORS
REFLECTED CEILING PLAN
SCALE: 1/8• _ ,• -0•
pj.
CEILING LEGEND
®
EXISTING 2 X 4 DEEP
CELL FLUORESCENT LIGHT
NEW 2' X 4' DEEP CELL
#3
PARABOLIC LENSE LIGHT FIXTURE
EXISTING 2 X 4 FLUORESCENT
LIGHT FIXTURE TO BE RELOCATED
RELOCATED 2 X 4 FLUORESCENT
LIGHT FIXTURE
- O
INCANDESCENT DOWNUGHT
EXISTING
TIITIION
�f1
E REC INDICATION
wWDfRECTAIO�N
i8ftR
EXIT LIGHT
MIDICATION D AL -LITE
18ItN
NEW C MTD. EXIT
LIGHT &DCTbN
INDICA DUAL -CITE
SMOKE ALARM
2 X 2 LAY -IN GRID
SUSPENSION SYSTEM
1 _
i-
NEW 2' X 2' CEILING GRID AND
AND TILES TO BE INSTALLED
- + - -�-
TO MATCH EXISTING.
®
THERMOSTAT
SMOKE DETECTOR
SWITCH
#3
THREE -WAY SWITCH
•
I. REPLACE ANY DAMAGED OR ^ MISSING TkES TO MATCH EXISTING.
CONTRACTOR TO VERIFY EXISTING .GRIO LAYOUT AND
CONDITION.
2. ELECTRICAL CONTRACTOR IS RESPdMMLE FOR DESIGN /BUILD
OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY
UANT1TY'AND PLACEMENT OF INDICAT&D SAFETY DEVICES
EXIT SIGNS, ALARMS. etc.) AND . VERIFY CONFORMANCE
ITH LOCAL, AND `STATE CODES. LIFESAFETY CONTRACTOR.
IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR
REVIEW AND OSTAWNG PERMITS.
3. ALL ROOM WALLS` TO UNDERSIDE OF SUSPENDED CEILING
TYPICAL UNLESS OTHERWISE N07M SEE WALL TAGS/WALL LEGEND
FOR INFORMATION.
4. _PATCH, REPAIR, AND /OR REPLACE CEILING GRID SYSTEM WHERE
WALLS, LIGHT FIXTURES. PROJECTION SCREENS OR PARTITIONS
HAVE BEEN REMOVED TO MATCH EXISTING.
5. RE -USE EXISTING TIGHT FIXTURES WHERE SHOWN, CLEAN
SALVAGED FIXTURES, RE -LAMP AMD3 REPLACE ANY DAMAGED
LENSES.
6. MECHANICAL AND ELECTRICAL IS DESIGN- BUILD. DESIGN -BUILD
CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE
DESIGN OF RELOCATED AND. NEW DIFFUSERS, SPRINKLER
HEADS, FIRE PROTECTION DEVICE'S. EM LIGHTS, EMERGENCY
NIGHT LIGHTS, AND THERMOSTATS. DE0014 -BUILD CONTRACTOR
TO COORDINATE HIS WORK WITH THE LIGHTING PLAN.
ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION
OF THE DESIGNER BEFORE PROCEEDING. REFER TO
MECHANICAL DRAWINGS FOR RELOCATKW OF.
THERMOSTATS. CONTRACTOR 'TO VERIFY IM TENANT
AND FURNITURE SUPPLIER T14ERMOSTAT LOCATIONS FOR
PANEL LOCATION CONFLICTS SEPORE PROCEEDING.
7. RE -LAMP ALL EXISTING LIGHT FIXTURES TO MEET T -8
REQUIREMENTS.
8. CEILING HEIGHT, IS I0'-6' A.F.F. UNLESS OTHERWISE NOTED. Flila wy}(.
9. RELOCATE EXISTING NECESSARY. SECT IDUE TO NEW LIGHT
10. SUSPENSION CEILING; ACOUSTICAL CEILING TILE AND LIGHTING
INDICATED FOR, PC STORAGE EXPANSION" #03, OFFICES 104, 105,
106 107 AND OPEN OFFICE 10$ IS WV. MATCH EXISTING
BUILDING STANDARDS.
ca, NEW CEIUNG GRID TO BE TIED INTO EXISTING
GRID, DUE .TO REMOVAL OF DRYWALL CEILING OR
REMOVED CEILING GRID.
O NEW BULKHEAD RETIRED.
aPa NEW GRID, ACOUSTICAL CEILING TILE, LIGHTING, HVAC, AND FIRE
PROTECTION REQUIRED.