Loading...
HomeMy WebLinkAbout1214.97.4J J t tow 1"A OPEN OFFICE AREA REFLECTED CEILING PLAN SCALE: 1/8' = 1. -0' NORTH OPEN OFFICE AND 8WITCHBO/UiD OPERATORS REFLECTED CEILING PLAN SCALE: 1/8• _ ,• -0• pj. CEILING LEGEND ® EXISTING 2 X 4 DEEP CELL FLUORESCENT LIGHT NEW 2' X 4' DEEP CELL #3 PARABOLIC LENSE LIGHT FIXTURE EXISTING 2 X 4 FLUORESCENT LIGHT FIXTURE TO BE RELOCATED RELOCATED 2 X 4 FLUORESCENT LIGHT FIXTURE - O INCANDESCENT DOWNUGHT EXISTING TIITIION �f1 E REC INDICATION wWDfRECTAIO�N i8ftR EXIT LIGHT MIDICATION D AL -LITE 18ItN NEW C MTD. EXIT LIGHT &DCTbN INDICA DUAL -CITE SMOKE ALARM 2 X 2 LAY -IN GRID SUSPENSION SYSTEM 1 _ i- NEW 2' X 2' CEILING GRID AND AND TILES TO BE INSTALLED - + - -�- TO MATCH EXISTING. ® THERMOSTAT SMOKE DETECTOR SWITCH #3 THREE -WAY SWITCH • I. REPLACE ANY DAMAGED OR ^ MISSING TkES TO MATCH EXISTING. CONTRACTOR TO VERIFY EXISTING .GRIO LAYOUT AND CONDITION. 2. ELECTRICAL CONTRACTOR IS RESPdMMLE FOR DESIGN /BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY UANT1TY'AND PLACEMENT OF INDICAT&D SAFETY DEVICES EXIT SIGNS, ALARMS. etc.) AND . VERIFY CONFORMANCE ITH LOCAL, AND `STATE CODES. LIFESAFETY CONTRACTOR. IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OSTAWNG PERMITS. 3. ALL ROOM WALLS` TO UNDERSIDE OF SUSPENDED CEILING TYPICAL UNLESS OTHERWISE N07M SEE WALL TAGS/WALL LEGEND FOR INFORMATION. 4. _PATCH, REPAIR, AND /OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES. PROJECTION SCREENS OR PARTITIONS HAVE BEEN REMOVED TO MATCH EXISTING. 5. RE -USE EXISTING TIGHT FIXTURES WHERE SHOWN, CLEAN SALVAGED FIXTURES, RE -LAMP AMD3 REPLACE ANY DAMAGED LENSES. 6. MECHANICAL AND ELECTRICAL IS DESIGN- BUILD. DESIGN -BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND. NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICE'S. EM LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DE0014 -BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATKW OF. THERMOSTATS. CONTRACTOR 'TO VERIFY IM TENANT AND FURNITURE SUPPLIER T14ERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS SEPORE PROCEEDING. 7. RE -LAMP ALL EXISTING LIGHT FIXTURES TO MEET T -8 REQUIREMENTS. 8. CEILING HEIGHT, IS I0'-6' A.F.F. UNLESS OTHERWISE NOTED. Flila wy}(. 9. RELOCATE EXISTING NECESSARY. SECT IDUE TO NEW LIGHT 10. SUSPENSION CEILING; ACOUSTICAL CEILING TILE AND LIGHTING INDICATED FOR, PC STORAGE EXPANSION" #03, OFFICES 104, 105, 106 107 AND OPEN OFFICE 10$ IS WV. MATCH EXISTING BUILDING STANDARDS. ca, NEW CEIUNG GRID TO BE TIED INTO EXISTING GRID, DUE .TO REMOVAL OF DRYWALL CEILING OR REMOVED CEILING GRID. O NEW BULKHEAD RETIRED. aPa NEW GRID, ACOUSTICAL CEILING TILE, LIGHTING, HVAC, AND FIRE PROTECTION REQUIRED. I a i m Z Cl Mimi Z z o�J J V m � W� 0,§ U W J Cj) .7S W 0 cr U IN I