HomeMy WebLinkAbout1218.97.13FIRE PROTECTION OEF/NI TONS WORKING PLANS AS USED IN THIS SEC110N MEAN THOSE DOCUMENTS (INCLUDING DRAWINGS AND HYDRAULIC CALCULA BONS) PREPARED PURSUANT TO THE REQUIREMENTS CONTAINED IN NFPA 13 CURRENTLY ENFORCED EDITION FOR OBTAINING APPROVAL OF THE AUTHORITY HAVING JURISDICTION. OTHER DEFINITIONS FOR FIRE PROTECTION SYSTEMS ARE LISTED IN NFPA 13. SYSTEM DESCRIPTION FIRE PROTECTION SYSTEM IS A "WET- PIPE" SYSTEM EMPLOYING AUTOMATIC SPRINKLERS ATTACHED TO A PIPING SYSTEM CONTAINING WATER AND CONNECTED TO AN UNDERGROUND Cl TY WA TER SUPPL Y SO THA T WA TER DISCHARGES IMMED/A TEL Y FROM SPRINKLERS OPENED BY FIRE WHICH IS REQUIRED THROUGHOUT THE PAR77AL SEVENTH FLOOR REMODEL AREA AS INDICATED ON THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL PROVIDE A HYDRAULICALLY CALCULATED WET PIPE AUTOMATIC FIRE SPRINKLER SYSTEM DESIGNED AND INSTALLED TO PRODUCE DENSITIES OF NOT LESS THAN 0.10 GPM PER SQUARE FOOT FOR THE HYDRAULICALLY MOST REM07F 1500 SQUARE FEET IN ALL LIGHT HAZARD AREAS BASED ON THE USE OF 165 DEGREE F TEMPERATURE RATED HEADS SPACED AT A MAXIMUM OF 225 SQUARE FEET PER HEAD; AND TO PROVIDE DENSITIES OF NOT LESS THAN 0.15 GPM PER SQUARE FOOT FOR THE HYDRAULICALLY MOST REMOTE 2000 SQUARE FEET IN ALL MECHANICAL /ELECTRICAL EQUIPMENT ROOMS BASED ON THE USE OF 286' F TEMPERA TURF RA TED HEADS SPACED A T A MAXIMUM OF 130 SQUARE FEET PER HEAD AND TO PROVIDE DENSITIES OF NOT LESS THAN 0.20 GPM PER SQUARE FOOT FOR THE HYDRAULICALLY MOST REMOTE .3000 SOUARE FEET IN ALL STORAGE ROOMS BASED ON THE USE OF 286' F TEMPERATURE RATED HEADS SPACED AT A MAXIMUM OF 130 SQUARE FEET PER HEAD. SUBMI TTALS PRODUCT DATA: SUBM /T MANUFACTURERS TECHNICAL PRODUCT DATA AND INSTALLA77ON INSTRUCTIONS FOR EACH TYPE SPRINKLER HEAD, VALVE, PIPING SPECIALTY, AND FIRE PROTECTION SPECIALTY. SHOP DRAWINGS: OBTAIN EXISTING STATE APPROVED WORKING PLANS AND REVISE AS REQUIRED. AUTOMATIC SPRINKLER FIRE PROTECTION DRAWINGS AND CALCULATIONS PREPARED IN ACCORDANCE W1 TH NFPA 13 IDENTIFIED AS "WORKING PLANS, " SHALL BE SUBMITTED TO FACTORY MUTUAL (F.M.) FOR REVIEW AND COMMENT AND TO THE LOCAL AUTHORITY HAVING JURISDICTION. ALL EQUIPMENT SHALL BE FACTORY MUTUAL RESEARCH CORPORATION (F. M. R. C) APPROVED. MAINTENANCE DATA: SUBMIT MAINTENANCE DATA AND PARTS LISTS FOR EACH TYPE SPRINKLER HEAD, PIPING SPECIAL TY AND FIRE PROTECTION SPECIAL TY, FOR INCLUSION IN OPERATING AND MAINTENANCE MANUAL. WELDERS QUALIFICATION CERTIFICATES. TEST REPORTS AND CERTIFICATES SUBMIT TEST REPORTS AND CERTIFICATES INCLUDING "CONTRACTORS MATERIAL AND TEST CERTIFICATE FOR ABOVEGROUND PIPING" AS DESCRIBED IN NFPA 13 UALI TY ASSURANCE INSTALLER QUALIFICA TIONS: INS TALLA T/ON AND AL TFRA TIONS OF FIRE PROTECTION PIPING, EQUIPMENT, SPECIALTIES, AND ACCESSORIES, AND REPAIR AND SERVICING OF EQUIPMENT SHALL BE PERFORMED BY ONLY A QUALIFIED INSTALLER. THE TERM QUALIFIED MEANS EXPERIENCED IN SUCH WORK (EXPERIENCED SHALL MEAN HAVING A MINIMUM OF FIVE PREVIOUS PROJECTS SIMILAR IN SIZE AND SCOPE TO THIS PROJECT), FAMILIAR WITH ALL PRECAU77ONS REQUIRED, AND HAS COMPLIED WITH ALL REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTON. QUALIFICATIONS FOR WELDING PROCESSES AND OPERA TIONS COMPLY WI TH THE REQUIREMENTS OF AWS D10.9 SPECIFICA77ONS FOR QUALIFICATIONS OF WELDING PROCEDURES AND WELDERS FOR PIPING AND TUBING, LEVEL AR -3. REGULATORY REQUIREMENTS: COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING CODES: NFPA 13: STANDARD FOR THE INSTALLA RON OF SPRINKLER SYSTEMS, CURRENTLY ENFORCED EDITION UL AND FM COMPLIANCE: FIRE PROTECTION SYSTEM MATERIALS AND COMPONENTS SHALL BE UNDERWRITERS LABORATORIES LISTED AND LABELED, AND FACTORY MUTUAL RESEARCH CORPORATION (FMRC) APPROVED FOR THE APPLICATION ANTICIPATFD. AUTHORITY HAVING JURISDICTION PUBLIC SAFETY FIRE PREVENTION AND BUILDING SAFETY COMMISSION COMPLIANCE: INSTALL FIRE PROTECTION SYSTEMS IN ACCORDANCE WITH LOCAL REQUIREMENTS OF FIRE MARSHAL. CODES: INDIANA BUILDING CODE (675 /AC 13) CURRENTL Y ENFORCED EDI RON. INDIANA FIRE PROTECTION CODE (6 75 1A 22) CURRENTL Y ENFORCED EDI TION. INDIANA MECHANICAL CODE (675 IAC 18) CURRENTLY ENFORCED EDITION. INDIANA PLUMBING CODE (6 75 1A 16) CURRENTLY ENFORCED EDITION. INSURANCE PURPOSES UNDERWRI TER'S LABORA TORIES AND KEMPER NA T70NAL INSURANCE. KEMPER: COMPL Y Wl TH KEMPER NA 77ONAL INSURANCE REGULA TIONS PER TA/N/NG TO FIRE PROTECTION SYSTEMS. CLEVELAND DISTRICT KEMPER NATIONAL INSURANCE COMPANIES - HPR DEPAR TMEN T 660 PARK AVENUE WEST P.O. BOX 234 MANSFIELD, OHIO 44901 -0234 SEQUENCING AND SCHEDULING SCHEDULE ROUGH -IN INSTALLATIONS WITH INSTALLATIONS OF OTHER BUILDING COMPONEN TS PIPING INSTALLA T70NS LOCATIONS AND ARRANGEMENTS: INSTALL NEW CROSS MA /NS AND BRANCH PIPING TO NEW SPRINKLER HEADS AS REQUIRED FROM EXISTING FIRE MAIN TO REMODELED AREA. CONTRACTOR TO VERIFY EXISTING CONDITIONS PRIOR TO START OF WORK. INSTALL SPRINKLER TO PROVIDE FOR SYSTEM DRAINAGE IN ACCORDANCE WITH NFPA 13. USE APPROVED FITTINGS TO MAKE ALL CHANGES IN DIRECTION, BRANCH TAKEOFF FROM MAINS, AND REDUCTIONS IN PIPE SIZES HANGERS AND SUPPORTS.' COMPLY WITH THE REQUIREMENTS OF NFPA 13. HANGER AND SUPPORT SPACING AND LOCATIONS FOR PIPING JOINED WITH GROOVED MECHANICAL COUPLINGS SHALL BE IN ACCORDANCE W17H THE GROOVED MECHANICAL COUPLING MANUFACTURERS WRITTEN INSTRUCTIONS, FOR RIGID SYSTEMS. PROVIDE PROTECTION FROM DAMAGE WHERE SUBJECT TO EARTHQUAKE IN ACCORDANCE WITH NFPA 13. AU TOMA TIC SPRINKLERS SPRINKLER HEADS FUSIBLE LINK TYPE, AND STYLE AS REQUIRED BY THE APPLICATION. UNLESS OTHERWISE INDICATED, PROVIDE HEADS WITH "ORDINARY" TEMPERA TURF RANGE. SPRINKLER HEAD FINISHES: PROVIDE HEADS WITH THE FOLLOWING FINISHES CONCEALED STYLE: BRIGHT CHROME, WITH PAINTED WHITE ESCUTCHEON PLATE FRIC17ON F/T PLATES NOT ALLOINEO. S/DEWALL STYLE: BRIGHT CHROME WITH WHITE ESCUTCHEON SPRINKLER HEAD INSTALLATION SPRINKLER HEADS SHALL BE LOCATED IN THE CENTER OF TILE IN AREAS W1TH 2x2 FEET CEILING TILES, EXCEPT WHERE EXTRA HEADS ARE REQUIRED. THEY MAY BE LOCATED ON EITHER CENTERLINE OF THE TILE TO WITHIN 6" OF THE GRID LINE. HEADS MAY ALSO BE LOCATED AT THE 6" DIMENSION FROM THE GRID LINE AT THE CORNER OF THE TILE. USE PROPER TOOLS TO PREVENT DAMAGE DURING INSTALLATION. FIELD QUALITY CONTRO SPRINKLER PIPING FLUSHING: PRIOR TO CONNECTING SPRINKLER RISERS FOR FLUSHING, FLUSH WATER FEED MAINS, LEAD -IN CONNECTIONS AND CONTROL PORTIONS OF SPRINKLER PIPING. AFTER FIRE SPRINKLER PIPING INSTALLATION HAS BEEN COMPLETE AND BEFORE PIPING IS PLACED IN SERVICE, FLUSH ENTIRE SPRINKLER SYSTEM IN PROJECT AREA AS REQUIRED TO REMOVE FOREIGN SUBSTANCES, UNDER PRESSURE AS SPECIFIED IN NFPA 13 CONTINUE FLUSHING UNTIL WA TER IS CLEAR, AND CHECK TO ENSURE THAT DEBRIS HAS NOT CLOGGED SPRINKLERS. HYDROSTATIC TESTING: AFTER FLUSHING SYSTEM, TEST FIRE SPRINKLER PIPING HYDROSTA 77CALL Y, FOR A PERIOD OF TWO HOURS, AT NO LESS THAN 200 PSI CHECK SYSTEM FOR LEAKAGE OF JOINTS MEASURE HYDROSTATIC PRESSURE AT LOW POINT OF EACH SYSTEM OR ZONE BEING TESTED. REPAIR OR REPLACE PIPING SYSTEM AS REQUIRED TO EL/MINA TE LEAKAGE IN ACCORDANCE WITH NFPA STANDARDS FOR "LITTLE OR NO LEAKAGE" AND RETEST AS SPECIFIED TO OEMONSTRA TE COMPLIANCE. TESTING AND CERTIFICATION REPORTS SHALL BE PROVIDED TO THE OWNERS AGENT AND THE ENGINEER, UPON COMPLETION. SPECIFICATIONS PL UMBING FIXTURES WATER CLOSET P- 1H.- AMERICAN STANDARD 2168.100, CADET, 17" HIGH, 1.6 GPF PRESSURE - ASSISTED, ELONGATED WHITE VITREOUS CHINA FLOOR OUTLET SIPHON JET BOWL WITH CLOSE- COUPLED TANK; 112" I.P.S. x 318" O.D. ANGLE STOP WALL SUPPLY WITH CLOSET RISER, FL OA T VA VE W1 TH VACUUM BREAKER, FLUSH VA VE, CHROME PLATED PUSH - BUTTON ACTUATOR, OLSON17E 95 WHITE SOLID PLASTIC OPEN FRONT INTEGRAL CHECK SEAT LAVATORY P -2H: AMERICAN STANDARD 0355.012, LUCERNE, 20 "x18" WH /TF VITREOUS CHINA HIGH BACK BASIN FOR CONCEALED ARM BRACKET, CHICAGO 802A -E2805 -317, 0.5 GPM, VANDAL RESISTANT, SUPPLY FITTING WITH 4- WRIST BLADE HANDLES, AMERICAN STANDARD 7723018 GRID DRAIN ASSEMBLY WITH 4 -112" OFFSET TAILPIECE; 17 -GAUGE ADJUSTABLE P- TRAP WITH CLEANOUT AND WITH ESCUTCHEON, 112" LP.S x 318" O.D. LOOSE KEY ANGLE STOP SUPPLIES WITH FLEXIBLE RISERS AND 112" CHROME PLATED NIPPLES AND ESCUTCHEONS; J. R. SM/ TH 700 FL OOR MOUN TED CONCEALED ARM SUPPOR T. INSULA TE DRAIN AND WA TER SUPPLIES SINGLE COMPARTMENT SINK P -3.• ELKAY MODEL LR -1517, 15"x17 112" O.D. SINGLE COMPARTMENT 18 GAUGE STAINLESS STEEL SELF -RIM COUNTER INSERT THREE HOLE LEDGE SINK WITH 7 -112" DEEP BOWL; ELKAY LK 35 STANDARD DUO- STRAINER WITH CHROME PLATED BRASS TAILPIECE, • CHICAGO NO 786 -FC GOOSENECK SPOUT WITH LAMINAR FLOW OUTLET, 4" WRIST BLADE HANDLES, 1.6 GPM INTEGRAL FLOW CONTROL AND 112" I.P.S. x 112" O.D. ANGLE STOPS W1 TH SUPPLY TUBING; TWO TWO PIECE 17 -GAUGE ADJUSTABLE P- TRAP W1 TH CLEANOUT WI TH ESCUTCHEON. CLINIC SERVICE SINK P -4: CLINIC SERVICE SINK, BLOW-OUT, WALL HUNG WHITE V/ TREOUS CHINA WITH 1 -112" TOP SPUD, AMERICAN STANDARD )Y9512-013; X78,32.017 STAINLESS STEEL RIM GUARDS FRONT AND SIDES; #37640.02 CHROME PLATED CAST METAL LOOSE STRAINER, CHICAGO FAUCET 1910 -G- 777 -19K AND 1814 -VB FAUCET WITH VACUUM BREAKER AND, 6" WRIST BLADES,' FIXED MIXING SPOUT, • PAIL HOOK AND WALL BRACE FOR ATTACHING FLUSH PIPE. SLOAN ROYAL" FLUSH VALVE j177H; CARRIER,- J.R. SMITH; FIG. 915 -M31. SCRUB -UP SINK P -5: AMERICAN STANDARD 9047.093, 30 x22" WHITE VITREOUS CHINA, SINGLE CENTER HOLE PUNCHING, HIGH BACK SURGEON SCRUB -UP SINK WITH ENAMELED CAST IRON WALL BRACKETS,' AMERICAN STANDARD 7679.012 WALL HUNG DOUBLE PEDAL VALVE WI TH LONG PEDALS. AND LOOSE KEY ANGLE STOPS, AMERICAN STANDARD 7522.055 GOOSENECK SPOUT WITH AERATOR; AMERICAN STANDARD 7716.020 GRID STAINER, TWO PIECE CAST BRASS P- TRAP WITH CLEANOUT AND BRASS WASTE NIPPLE WITH ESCUTCHEON; J.R. SMITH #870 -KW CARRIER, DOUBLE COMPARTMENT SINK P -6. ELKAY LR 3322, 33 "x22" O.D. DOUBLE COMPARTMENT 18- GAUGE, STAINLESS STEEL SELF -RIM COUNTER INSERT THREE HOLE LEDGE SINK WITH 8 " DEEP BOWL; CHICAGO 786 -E3 COMBINATON FAUCET WITH 4" WRIST BLADE HANDLES AND GOOSENECK SPOUT, ELKAY LK -35 STANDARD DUO STRAINER WITH TAILPIECE; TWO PIECE 17 -GAUGE P- TRAP Wl TH CLEANOUT WITH ESCUTCHEON; 1/2" I. P. S. x 112 " O.D. ANGLE STOPS WI TH SUPPL Y TUBING, SINGLE COMPARTMENT SINK P -7: RELOCATE EXISTING STAINLESS STEEL SINK OF SIZE 31 "x21 " WITH GOOSENECK FAUCET AND 4" WRIST BLADE HANDLES. PROVIDE NEW, TWO PIECE 17 -GAUGE P- TRAP WITH CLEANOUT WITH A CHROME PLATED WALL ESCUTCHEON AND 112" I. P. S. x 112 " O. D. ANGLE S TOPS WI TH SUPPL Y TUBING. MOP BASIN P -8: F/A T MSB2424 24 "x24 " MOLDED STONE RECEPTOR W1 TH BRASS DRAIN BODY, STAINLESS STEEL DOME STRAINER -LINT BASKET, VINYL BUMPER GUARD; CHICAGO 897 SUPPLY FI T77NG Wl TH INTEGRAL STOPS, VACUUM BREAKER, BUCKET HOOK, WALL BRACE, AND 314" HOSE THREAD ON SPOUT, FIAT 832 -AA, 30" LONG HEAVY -DUTY CLOTH REINFORCED, 889 -CC STAINLESS STEEL MOP HANGER WITH THREE RUBBER TOOL GRIPS, 833 -AA SILICONE SEALANT SINGLE COMPARTMENT SINK P -9: ELKAY LR2522 25 "x22" O.D. SINGLE COMPARTMENT 18 -GAUGE STAINLESS STEEL SELF -RIM COUNTER INSERT THREE HOLE LEDGE SINK WITH 8" DEEP BOWL; MOEN MODEL 7533B WASHERLESS IPS SINGLE LEVER KITCHEN DECK FAUCET, STANDARD DUO STRAINER WITH TAILPIECE; 17 -GAUGE ADJUSTABLE P -TRAP WITH CLEANOUT PLUG WITH ESCUTCHEON; 112" I.P. S. x 112" 0. D. ANGLE STOPS WITH SUPPLY TUBING. SINGLE COMPARTMENT SINK P -10: ELKAY "LUSTERTONE" DLR- 1919 -10, 19 -112 "x19" SINGLE COMPARTMENT 18- GAUGE, TYPE 302 STAINLESS STEEL SELF RIM COUNTER INSERT THREE HOLE LEDGE SINK WITH 10" DEEP BOWL. ELKAY LK -335, J-112" OPENING STRAINER BODY, STRAINER AND 1 -112" TAIL PIECE- CHICAGO 786 -E3 COMBINATION FAUCET WITH 4" WRIST BLADE HANDLES AND GOOSENECK SPOUT, • TWO PIECE 17 -GAUGE ADJUSTABLE P- TRAP WITH CLEANOUT- 112" I.P. S. x 112" O.D. ANGLE STOPS WITH SUPPLY TUBING. WA TER10RA/N BOX P -11: GUY GRA Y B -200 CONTROL BOX W1 TH HOT AND COLD WA TER CONTROL VALVES AND 2 DRAIN CONNECTION. MOUNTING HEIGHT AS SHOWN ON THE FIXTURE SCHEDULE FLOOR DRAIN (ABOVE GRADE TYPE A FOR FINISHED OR NON- FINISHED AREAS BENEATH EQUIPMENT WITH LIMITED CLEARANCE, CAST -IRON BODY AND FLASHING COLLAR, NICKEL BRONZE ADJUSTABLE ROUND STRAINER HEAD AND GRATE WITH ANTI -FLOOD RIM RECESS AND DEEP SEAL P- TRAP; SMITH 2005 -F37 BASIC PIPE AND FITTINGS ABOVE GROUND SOIL, WASTE, AND VENT PIPING PIPE SIZE 6" AND SMALLER: HUBLESS CAST -IRON SOIL PIPE,- SERVICE WEIGHT HUBLESS CAST -IRON SOIL PIPE FITTINGS, HUBLESS JOINTS. PIPE SIZE 2" AND SMALLER: GALVANIZED STEEL PIPE; SCHEDULE 40: CAST -IRON SCREW JOINT DRAINAGE PATTERN, FITRNGS. D.W.V. COPPER IS ALSO ACCEPTABLE. ABOVE GROUND STORM CONDUCTOR PIPING: PIPE SIZE 10" AND SMALLER: HUBLESS CAST -IRON SOIL PIPE, SERVICE WEIGHT. HUBLESS CAST -IRON SOIL PIPE FITTINGS, HUBLESS JOINTS. ABOVE GROUND DOMESTIC WA TER PIPING INTERIOR DOMESTIC WATER PIPING SHALL 3E TYPE L" HARD DRAWN COPPER TUBE ASTM B88, WROUGHT COPPER FITTINGS, AND ASTM B32, 95 -5 LEAD FREE SOLDERED JOINTS. INSULA TION DOMESTIC COLD WATER AND HOT WATER PIPING SHALL BE INSULATED Wl TH 1/2" THICK OWENS CORNING FIBERGLASS ASJ- SSJ -11 "ONE PIECE" PIPE INSULATION W1TH FACTORY APPLIED JACKET AND SELF SEALING LAP, OR APPROVED EQUAL. NO TE: NO PROVISIONS FOR MEDICAL GASES ARE REQUIRED IN THIS PROJECT DESIGN. PORTABLE GASES ARE TO BE PROVIDED BY THE TENANT IF REQUIRED. BSA DESIGN 6810 N SHADELAND AVE INDIANAPOLIS INDIANA 46220.4287 317.849.7878 PH 317.849.2288 FX v .•GIST R `•. No. 13815_ STATE OF iA/ nti.i Pf �: MOORE ENGINEERS A PROFESSIONAL CORPORATION 9245 N. Meridian Street, Suite 105 Indianapolis, Indiana 46260 -1812 317.848.5045 PH 317.848.2765 FX Vincent St. Carmel hospital 13600 N. Merldisn 8'trest P.O. Boz 18w CumeL Iadlana 4802 CARMEL MEDICAL BUILDING No. 1 SUITE 315/355 Carmel, Indiana PLUMBING SPECIFICATIONS SCALE 1/8" - 1' -0" CLIENT NO. DATE 9 -29 -97 COMMISSION 97055 COORD GB DRAWN GB P4 APPROVED GM