HomeMy WebLinkAbout1218.97.19I,- 0) rn N N Ln co N CL N cn L I cD W Ln Ln 0 ti rn F_ U W ___ ELECTRICAL SPECIFICATIONS ASIC E' TRICAL REQUIREMENT. MATERIAL SUBS D 1U RONS.• MA TERIALS, EQUIPMEN T AND SPECIAL TY / EMS SHOWN IN THESE DRAWINGS AND SPECIFICATIONS ARE SPECIFIED AROUND A LIST OF BRAND NAMES KNOWN AND PERFORMANCE PROVEN TO THE ENGINEER. ONL Y THOSE MANUFACTURERS NAMED IN THESE DRAWINGS AND SPECIFICATIONS OR IN A WRITTEN ADDENDUM WILL BE APPROVED FOR THIS PROJECT. THE TERMS "OR EQUAL" AND "APPROVED EQUAL" ARE MEANT TO APPLY ONLY TO THOSE MANUFACTURERS AND BRAND NAMES LISTED HEREIN AND DOES NOT IMPLY "OR EQUAL" OUTSIDE THE LIMITS OF THE NAMED MANUFACTURERS. THE ENGINEER RESERVES THE SOLE RIGHT FOR THE APPROVAL OF PROPOSED ADDITIONAL MANUFACTURERS, MATERIALS OR EQUIPMENT. SUBMITTALS: SUBMIT 8 COPIES OF BROCHURES, CATALOG CUTS, TECHNICAL DATA OR DRAWINGS OF ALL EQUIPMENT OR MATERIALS. SHOP DRAWINGS SHALL STATE CAPACITIES, PHYSICAL DIMENSIONS AND WEIGHTS AS WELL AS FULLY DESCRIBE ALL OPT70NS AND APPURTENANCES NECESSARY TO DEMONSTRATE THAT THE EQUIPMENT MEETS THE INTENT OF THESE DRAWINGS AND SPECIF/CAT70NS. THE REVIEW OF SHOP DRAWINGS BY THE ENGINEER DOES NOT RELIEVE THE CONTRACTOR OF IHE RESPONSIBILITY OF COMPLYING WITH THESE CONTRACT DOCUMEN TS. PERMITS AND /NSPECTI NS.• THE CONTRACTOR SHALL OBTAIN AND FURNISH ALL NECESSARY PERMI IS AND INSPECTION CER77FICA TES FOR ALL MA ERIAL AND LABOR FURNISHED BY HIM. THE COST OF PERMITS, CER77FICATES ANO ALL FEES REQUIRED IN CONNECTION WITH THE INSTALLATION SHALL BE BORNE BY THE CONTRACTOR. WHERE APPL /CA77ONS ARE REQUIRED FOR THE PROCURING OF UTILITY SERVICES TO THE BUILDING, THIS CONTRACTOR SHALL SEE THAT SUCH APPLICATION IS PROPERLY FILED WITH THE UTILITY. DRAWINGS: THE CONTRACTOR SHALL HAVE A COMPLETE SET OF DRAWINGS ON THE SITE AT ALL TIMES. THESE CONTRACT DRAWINGS FOR ELECTRICAL WORK ARE IN PART DIAGRAMMATIC, INTENDED TO CONVEY THE SCOPE OF WORK AND TO IND/CAE GENERAL ARRANGEMENT OF EQUIPMENT, CONDUITS, ETC. AND THE APPROXIMATE SIZES AND LOCATIONS OF EQUIPMENT AND MATERIALS. BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC /EMS SUCH AS CONDUIT FITTINGS, JUNCTION BOXES, PULL BOXES, ETC. MAY NOT BE SHOWN, BUT SHALL BE FURNISHED AND INSTALLED WHERE REQUIRED BY CODE OR BY THE NATURE OF THE WORK. THE CONTRACTOR SHALL LOCATE ALL EQUIPMENT WHICH MUST BE SERVICED, OPERAED OR MAINTAINED IN FULLY ACCESSIBLE POSIRONS STANDARDS OF MATERIALS AND WORKMANSHIP: ALL WORK SHALL CONFORM TO OR EXCEED THE MINIMUM REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE (NEC), THE CURRENTL Y ENFORCED ED/ RON, AND ALL FEDERAL, STA TE, LOCAL AND MUNICIPAL ORDINANCES. ALL MATERIALS SHALL BE NEW COMPLETE M 7 MANUFACTURER'S GUARANTEE OR WARRANTY, AND SHALL BE AS LISTED BY THE UNDERWRITERS' LABORATORIES (UL), INC., IF A STANDARD HAS BEEN ESTABLISHED FOR THA T TYPE OF MA TERIAL. ALL WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND SHALL PRESENT A NEAT MECHANICAL APPEARANCE WHEN COMPLETED. EXISTING CONDITIONS.• THIS CONTRACTOR SHALL EXAMINE THE EXISTING PROJECT SITE AND FAMILIARIZE HIMSELF WI T74 THE COND1 TIONS AS THEY EXIST, OR THAT WILL IN ANY MANNER AFFECT HIS WORK UNDER THIS CONTRACT. ALL CONDITIONS SHALL BE CONSIDERED IN THE PREPARATION OF BIDS. INTERRUPTION OF UTILITIES THIS CONTRACTOR SHALL MAKE ALL CHANGES IN SERVICES SO AS TO PROVIDE A MINIMUM OF INTERFERENCE WITH THE OPERATION OF THE BUILDING WHEN CHANGES REQUIRE A SHUTDOWN OF BUILDING SERVICES, THIS CONTRACTOR SHALL NOTIFY THE OWNER NOT LESS THAN 24 HOURS IN ADVANCE AND COORDINATE THE INTERRUPTION NTH THE OWNER. DAMAGES. ]HIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF OTHER TRADES OR TO THE FACILITY AND ITS CONTENTS CAUSED BY EQUIPMENT INSTALLED BY HIM. CLEAN -UP: THIS CONTRACTOR SHALL KEEP THE PREMISES CLEAN OF ALL DEBRIS CAUSED BY HIS WORK. AT THE CONCLUSION OF CONSTRUCTION, THE SITE SHALL BE THOROUGHLY CLEANED OF ALL RUBBLE, DEBRIS AND UNUSED MATER /ALS. aOSEOU T.• THIS CONTRACTOR SHALL PROVIDE ALL DOCUMENTS, AFFIDAVITS, GUARANTEES AND TRAINING REQUIRED FOR PROJECT CLOSEOUT INCLUDING THE FOLLOWING: OPERATING AND MAINTENANCE MANUALS RECORD "AS BUILT" DOCUMENTS GUARANTEES AND WARRANTIES TRAINING OF THE OWNERS REPRESENTATIVE EXTRA MATERIALS WITH RECEIPTS ASIC ELECTRICAL MATERIALS AND METH SUPPORTS. THIS CONTRACTOR SHALL PROVIDE MISCELLANEOUS LUMBER AND METAL FRAMING FOR THE SUPPORT OF ELECTRICAL MATERIALS AND EQUIPMENT. PROVIDE WOOD OR METAL GROUNDS, NAILERS, BLOCKING, FASTENERS AND ANCHORAGE AS REQUIRED. MATERIALS SHALL BE OF COMPARABLE QUALITY AND TYPE USED FOR THE GENERAL CONSTRUCT70N IN THE AREA WHERE INSTALLED. JOINT SEALERS: PROVIDE JOINT SEALERS FOR SEALING AROUND ELECTRICAL MATERIALS AND EQUIPMENT PROVIDE FIRE RESISTANT SEALERS WHERE CONDUIT AND /OR WIRING EXTENDS THROUGH FIRE AND /OR SMOKE RATED WALLS AND FLOORS. SEAL ALL CONDUIT PENETRATIONS OF THE BUILDING WALLS AND FOUNOA 77ONS BELOW GRADE. ACCESS DOORS: PROVIDE FACTORY FABRICATED AND ASSEMBLED STEEL ACCESS DOORS AND FRAMES IN WALLS, CEILING AND FLOORS AS REQUIRED FOR ACCESS TO ELECTRICAL MATERIALS AND EQUIPMENT. ROOF ACCESSORIES' CONDO/ T ROOF PENE IRA TIONS SHALL BE PRO VIDEO M TH PRE- FABRICATED PIPE PORTALS. PENETRATIONS SHALL BE COMPATIBLE WI 1H AND SUITABLE FOR THE ROOF MATERIALS. PROVIDE EPOM RUBBER SEAL CAPS TO ACCOMMODATE PIPE SIZES LISTED ON THE DRAWING. CABLE TIES: CABLE TIES SHALL BE FUNGUS - INSERT SELF- EXTINGUISHING, ONE- PIECE, SELF- LOCKING NYLON CABLE 77ES WITH 50 LBS MINIMUM TENSILE STRENGTH. RA CE WA Y GENERAL: ALL POWER WRING, ALL WIRING FOR OVER 24 VOLTS, AND OESIGNA TED SYSTEMS WIRING SHALL BE ROUTED IN AN APPROVED RACEWAY. ALL WIRING AND CONDUIT SHALL BE INSTALLED CONCEALED IN FINISHED SPACES EXCEPT WHERE SURFACE WIREWA YS ARE NO TED. CONDO/ T MA Y BE ROU TEO EXPOSED IN MECHANICAL AND ELECTRICAL ROOMS AND IN AREAS WHICH HAVE NO CEILINGS. OUTDOOR USE THE FOLLOWING WIRING METHODS-* RIGID METAL CONDUIT (GRC) IN TERMED /A E METAL CONDUI T (IMC) RIGID NON- METALLIC CONDUIT (RNC) (WHERE NOT EXPOSED TO DAMAGE) Ak2QR USE THE FOLLOWING WIRING METHODS RIGID METAL CONDUIT (GRC) IN TERMED /A E METAL CONDUIT (IMC) ELECTRICAL METALLIC TUBING (EMT) (NOT IN EARTH OR CONCRETE) RIGID NON- METALLIC CONDUIT (RNC) (WHERE NOT EXPOSED TO DAMAGE AND IN NON- PLENUM SPACES) ELECTRICAL NON- METALLIC TUBING (ENT) (CONCEALED LOCATIONS AND NON - PLENUM SPACES ONLY) W/REWA YS AND SURFACE RACEWAYS (WHERE INDICATED) SIZES. THE MINIMUM CONDUIT SIZE SHALL BE 314 INCH. FITTINGS: PROVIDE CONDUIT BODIES OF THE TYPES, SHAPES AND SIZES AS REQUIRED BY THE INSTALLATION AND THE NEC. USE METALLIC BODIES WITH STEEL CONDUIT, ALUMINUM WITH ALUMINUM CONDUIT AND PLASTIC WITH PLASTIC CONDUIT RIGID CONDUITS (GRC AND IMC) SHALL BE JOINED WITH THREADED TYPE CONNECTIONS AND COUPLINGS. EMT SHALL BE JOINED WITH CONNECTORS OF STEEL OR MALLEABLE IRON AND SHALL BE OF THE COMPRESSION OR SET SCREW TYPE. INDENTOR, FRICTION AND DIE -CAST METAL CONNECTORS WILL NOT BE PERMI TED. PROV/OE /NSULA TEO BUSHINGS A T ALL EN IRA NCES TO PANELBOARDS, STARTERS, PULL BOXES, ETC.. VIBRATING EQUIPMENT.• CONNECT TO VIBRATING EQUIPMENT AND HYDRAULIC, PNEUMATIC OR ELECTRIC SOLENOID OR MOTOR - DRIVEN EQUIPMENT WITH LIQUIDTIGHT FLEXIBLE METAL CONDUIT. WIRES AND CABLES GENERAL: PROVIDE WIRE AND CABLE WITH 600 VOLT /NSULA 77ON SUITABLE FOR THE TEMPERATURE, CONDITIONS AND LOCATIONS WHERE INSTALLED. MINIMUM SIZE BRANCH CONDUCTORS SHALL BE #12 AWG. C,ONOUCTORS PROVIDE SOLID CONDUCTORS FOR POWER AND LIGHTING CIRCUITS 110 AWG AND SMALLER. PROVIDE STRANDED CONDUCTORS FOR SIZES #8 AWG AND LARGER. (NSULA TION: PROVIDE THW, THHN, OR THWN FOR ALL CONDUCTOR INSULATION. (NOTE THAT CONDUIT SIZE SHOWN ON THESE DRAWINGS IS BASED ON THHN (NSULA TION, • LARGER CONOUI T MA Y BE REQUIRED FOR 0 THER /NSUL A RONS ) 120 VOL T CIRCUI TS- THE MINIMUM CONDUCTOR SIZE FOR 120 VOL T BRANCH CIRCUITS SHALL BE 112 AWG FOR CIRCUITS LESS THAN 60 FEET TO THE CIRCUIT CENTER, #10 AWG UP TO 100 FEET, • AND #8 AWG OVER 100 FEET UNLESS NO ED TO BE LARGER. 277 VOLT CIRCUITS.- THE MINIMUM CONDUCTOR SIZE FOR 277 VOL T BRANCH CIRCUITS SHALL BE #12 AWG FOR CIRCUITS LESS THAN 125 FEET TO THE CIRCUIT CENTER, 110 AWG UP TO 225 FEET, • AND 18 AWG UP TO 350 FEET. wa VEIN GENERAL: METAL -CLAD CABLE (MC) SHALL BE PERMITTED WHEREVER EMT OR ENT CONDUIT AND WIRING ARE PERMITTED FOR BRANCH CIRCUIT WORK. IT SHALL BE PERMITTED IN DRY LOCATIONS ONLY AND SHALL BE CONCEALED EXCEPT IN UNFINISHED SPACES. MINIMUM CONDUCTOR SIZE SHALL BE 112 AWG (REFER TO WIRES AND CABLES„ FOR BRANCH CIRCUIT MINIMUM CONDUCTOR SIZES). MC CABLE. MC CABLE SHALL BE INSTALLED IN ACCORDANCE WITH NEC ARTICLE 334, MC CABLE SHALL ALSO INCLUDE NEC TYPES CS (COPPER SHEATH) OR ALS (ALUMINUM SHEATH). MC CABLE MAY BE USED WITH CONDUCTOR SIZE 112 AND LARGER. ALL MC CABLE SHALL INCLUDE A SEPARATE, GREEN GROUNDING CONDUCTOR. HOSPITALS.- MC CABLES SHALL NOT BE USED FOR LIFE SAFETY BRANCH OR CRITICAL BRANCH EMERGENCY CIRCUITS OR FEEDERS IN MEDICAL FACILITIES ('AB/NE TS BOXES AND FITTINGS GENERAL: PROVIDE OUTLET AND OEVICE BOXES, PULL AND JUNCTION BOXES, CABINETS, HINGED DOOR ENCLOSURES AND BOXES AND FITTINGS FOR HAZARDOUS LOCATIONS AS INDICATED ON THESE DRAWINGS, AS REQUIRED BY THE NEC OR AS REQUIRED BY THE INS TALLA )ION. OUTLET DEVICE AND SMALL WIRING BOXES. PROVIDE METAL BOXES ON METAL RACEWAYS AND NON- METALLIC BOXES ON NON- METALLIC RACEWAYS. BOXES SHALL BE OF THE TYPE, SHAPE, SIZE AND DEPTH TO SUIT EACH LOCATION AND APPLICA RON. BOXES SHALL INCLUDE STAMPED KNOCKOUTS, THREADED SCREW HOLES AND APPROPRIATE ACCESSORIES SUCH AS MOUNTING BRACKETS AND STRAPS, CABLE CLAMPS, GROUNDING TERMINALS, EXTERIOR RINGS AND FIXTURE STUDS. PULL AND JUNCTION BOXES• PULL AND JUNCTION BOXES SHALL HAVE SCREWED OR BELTED COVERS AND SHALL BE OF THE SIZE AND SHAPE TO SUITE THE APPLICA RON. CABINETS. CABINETS SHALL CONSIST OF A BOX AND A FRONT WITH A ONE PIECE FRAME AND A HINGED DOOR. PROVIDE A FRONT WI TH APPROX/MA TEL Y 314 INCH OVERLAP ON ALL EDGES FOR FLUSH CABINETS AND THE SAME SIZE AS THE BOX FOR SURFACE CABINETS. HINGED DOOR NCLOSURES: ENCLOSURES WITH HINGED DOORS SHALL HAVE DOORS WHICH ARE HINGED DIRECTLY TO THE BOX AND REMOVABLE, WITH APPROXIMA TEL Y 314 INCH FLANGE AROUND ALL EDGES, SHAPED TO COVER THE BOX NON- METALLIC ENCLOSURES. MOLDED NON- METALLIC ENCLOSURES SHALL BE FIBERGLASS REINFORCED HIGH IMPACT STRENGTH POLYESTER WITH BOLT OR SCREW SECURED HINGED DOOR(S) AND SOLID NEOPRENE GASKETS. NEMA 1 CONSTRUCTION. PROVIDE THE FOLLOWING: S EEL BOXES HOT-DIPPED GALVANIZED STEEL BOXES NEMA 3 AND 3R CONSTRUCTION: PROVIDE THE FOLLOWING STEEL BOXES HOT- DIPPED GALVANIZED STEEL BOXES ACCESSORIES PROVIDE DOOR HANDLES, LATCHES, KEY LOCKS, DRIP GUARDS, MOUNTING PANELS, DOOR STOPS, PADLOCK HASPS AND OTHER ACCESSORIES AS REQUIRED. ALL BOXES, CABINETS AND ENCLOSURES WHICH ARE NOT SECURED BY SCREWS OR BOLTS SHALL HAVE PROVISIONS FOR LOCKING OR PAD LOCKING THE DOOR OR COVER. TRICAL CONNECTIONS FOR EQUIPMENT N RA : THIS CONTRACTOR SHALL EXTEND THE ELECTRICAL POWER WIRING TO EACH PIECE OF EQUIPMENT INDICATED ON THESE ORA41NGS AND SCHEDULES. THIS SHALL INCLUDE WIRING AND RACEWAY TO THE TERMINALS OF THE EQUIPMENT OR PLUG RECEPTACLE AS REQUIRED. U/PM N T. MOTOR STARTERS, DISCONNECT SW TCHES, JUNCTION BOXES, WHICH ARE NOT AN INTEGRAL PART OF THE EQUIPMENT FURNISHED BY OTHER TRADES OR THE OWNER SHALL BE PROVIDED AS A PART OF THIS WORK. WIRING DEVICES GENERAL: PROVIDE WIRING DEVICES OF THE TYPE, CHARACTERISTICS, GRADES, COLORS AND ELECTRICAL RATINGS FOR EACH APPLICATION INDICATED ON THESE DRA WINGS. MAN UFAC IURERS: ARROW HART BRYANT ELECTRIC COMPANY GENERAL ELECTRIC COMPANY HUBBELL, INC. LEW TON LUTRON MULBERRY PASS AND SEYMOUR, INC. SQUARE D STEEL CITY MIDLAND - ROSS CORP. WALKER DIVISION OF BUTLER MFG. CO. WIREMOLD GRADE. SWITCHES AND RECEPTACLES SHALL BE SPECIFICA T70N GRADE. COL R: GENERAL PURPOSE SWITCHES AND RECEPTACLES SHALL BE IVORY IN COLOR. DEVICES CONNECTED TO EMERGENCY CIRCUITS SHALL BE RED IN COLOR. SPECIAL PURPOSE OUTLETS (DEVICES OTHER THAN 15A OR 20A RATED) SHALL BE BLACK IN COLOR. ISOLATED GROUND RECEPTACLES SHALL BE ORANGE IN COLOR. SWI TCHES AC SKI TCHES SHALL BE QUIET OPERA TING AND RATED AT 20 AMPERES 1201277 VOLTS SW TCHES USED AS MOTOR DISCONNECTS SHALL BE MOTOR RATED AT 1 HORSEPOWER FOR 120 VOLTS, SINGLE -PHASE CIRCUITS. RECEPTACLES.• ALL RECEPTACLES SHALL BE GROUNDING TYPE. GENERAL PURPOSE DUPLEX RECEPTACLES SHALL BE RATED AT 15 AMPERES. COVERPLA TES: COVERPLA TES SHALL BE OF THE APPROPRIATE TYPE AND SIZE TO ACCOMMODATE THE DEVICES. COVERPLA TES SHALL BE THERMOSET OR PHENOLIC PLASTIC, NON- COMBUSTIBLE, MAR -PROOF MATERIAL AND SHALL MATCH THE COLOR OF THE GENERAL PURPOSE SWITCHES AND RECEPTACLES. WEATHERPROOF COVERPLAES SHALL BE PROVIDED FOR ALL EXTERIOR RECEPTACLES AND SWI TCHES OR WHERE INDICA TED ON THESE DRAWINGS. WET LOCH TION COVERPLAES SHALL BE LISTED AS "WET LOCATION WITH COVER CLOSED" AND SHALL HAVE A CLEAR-COVER WHICH CLOSES WITH A CORD SET PLUGGED INTO ]HE RECEPTACLE. DIMMER SWI TCHES.- INCANDESCENT LAMP DIMMERS SHALL BE 120 VOL T LINEAR SLIDE NTH OFF POSITION AT THE BOTTOM AND COLOR TO MATCH GENERAL PURPOSE DEVICES. DIMMER SHALL BE RATED 600 WATTS UNLESS O THERWISE NOTED OR REQUIRED BY THE APPLICATION. FLUORESCENT LAMP DIMMERS AND BALLASTS SHALL HAVE A DIMMING RANGE OF 100 PERCENT TO 1 PERCENT FOR LARGE LAMPS AND 100 PERCENT TO 5 PERCENT FOR COMPACT T4 AND T5 LAMPS. C RCUI T AND MOTOR DI SMAN -a TS GENERAL: PROVIDE CIRCUIT AND MOTOR DISCONNECT SWITCHES IN TYPES, SIZES, DUTIES, FEATURES, RATINGS AND ENCLOSURES AS INDICATED OR AS REQUIRED BY THE NEC OR BY THE APPL/CA RON. PROVIDE NEMA 1 ENCLOSURES FOR INDOOR SWITCHES ANO NEMA 3R ENCLOSURES WITH RAIN77GHT HUBS FOR EXTERIOR SWITCHES. FOR MOTORS AND MOTOR STARTER DISCONNECTS, PROVIDE UNITS WITH HORSEPOWER RATINGS SUITABLE FOR THE LOAD. MANUFACTURERS: ALLEN - BRADLEY CO. APPLETON CROUSE -HINDS CO. CUTLER - HAMMER GENERAL ELECTRIC I E/GOULD, INC. SIEMENS ENERGY & AUTOMATON, INC. SQUARE D COMPANY FUSIBLE SWITCHES: PROVIDE HEAVY DUTY SWITCHES WTH FUSES OF THE CLASSES AND CURRENT RATINGS INDICATED OR REQUIRED. PROVIDE UL SERVICE ENTRANCE LABEL WHERE USED AS MAIN SERVICE DISCONNECT. GROUNDING.• PROVIDE EQUIPMENT GROUNDING CONNECTIONS FOR DISCONNECT SWITCH ENCLOSURES AND GROUND IN ACCORDANCE WITH NEC AND AS STATED HEREIN. ELECTRICAL IDENTIFICATION GENERAL: PROVIDE IDENTIFICATION OF ELECTRICAL MAERIALS, EQUIPMENT AND INSTALLATIONS PROVIDE EQUIPMENT LABELS, WARNING AND CAUTION SIGNS, OPERATING INSTRUCTION SIGNS AND IDENTIFYING LABELS FOR THE FOLLOWING: PANELBOARDS, DISCONNECTS AND MOTOR STARTERS CONTACTORS AND RELAYS T/MECLOCKS CABINETS AND ENCLOSURES CONTROL AND ALARM PANELS WIRE /CABLE MARKERS' PROVIDE VINYL OR VINYL - CLOTH, SELF - ADHESIVE, WRAPAROUND, CABLE / CONOUCTOR MARKERS MT74 PREPR INTED NUMBERS AND LETTERS. ENGRAVED PLASTIC LAMINA E: PROVIDE ENGRAVED PLASTIC LAMINA ED LABELS, SIGNS AND INSTRUCTION PLATES OF STOCK MELAMINE PLASTIC. ENGRAVED LEGENDS SHALL BE WHITE LETTERS ON BLACK FACE. PROVIDE 1116 INCH THICK FOR SIGNS UP TO 20 SQUARE INCHES OR 8 INCHES IN LENGTH AND 118 INCH THICK FOR LARGER SIGNS. MYLAR LABLES PROVIDE A MACHINE LETTERED LABEL ON 112 INCH MYLAR TAPE. LETTERING SHALL BE 318 INCHES (36 POINT) HIGH WHITE LETTERS ON BLACK BACKGROUND. • INTERIOR SIGNS: PROVIDE ALUMINUM SIGNS WITH BAKED ENAMEL WARNINGS AND CAUTIONS IN COLORS, LEGEND AND SIZE AS APPROPRIATE. EXTERIOR SIGNS. PROVIDE WEATHER- RESISTANT, NONFADING, PREPRINTED CELLULOSE ACETATE BUTYRATE SIGNS WITH 20 GAGE, GALVANIZED STEEL BACKING IN COLORS, LEGEND AND SIZE AS APPROPRIATE PROVIDE A 114 INCH GROMMET IN EACH CORNER FOR MOUNTING. CONDUCTOR COLOR CODES. • PROVIDE COLOR CODING FOR SECONDARY SERVICE, FEEDER AND BRANCH CIRCUIT CONDUCTORS THROUGHOUT THE PROJECT SECONDARY ELECTRICAL SYSTEM AS FOLLOWS. PHASE 208YI120 -VOLTS 480YI277 VOL TS A BLACK YELLOW - B RED BROWN C BLUE ORANGE NEU IRA L WHI TE WH/ 7E/BLUE STRIPE GROUND GREEN GREEN /YELLOW STRIPE GROUNDING GENERAL: THIS CONTRACTOR SHALL SOLIDLY GROUND ALL ELECTRICAL SSTEMS AND EQUIPMENT. THE ELECTRICAL SYSTEM GROUND SHALL CONFORM TO THESE SPEC /F /CAT70NS AND TO THE DRAWINGS, BUT IN NO CASE SHALL IT BE LESS THAN THE REQUIREMENTS OF THE NEC. EQUIPMENT GROUNDING SYSTEM: THE EQUIPMENT GROUNDING SYSTEM SHALL GROUND ALL ELECTRICAL EQUIPMENT METALLIC RACEWAYS, ENCLOSURES AND ALL NONCURRENT - CARRYING PARTS OF ELECTRICAL EQUIPMENT, SOUND EQUIPMENT, ALARM SYSTEM EQUIPMENT, MECHANICAL EQUIPMENT AND OTyER BUILDING SYSTEM EQUIPMENT WHICH USES ELECTRICITY OR WHICH COULD BECOME ENERGIZED UNDER FAULT CONDITIONS. AN EQUIPMENT GROUNDNG CONDUCTOR, SIZED IN ACCORDANCE WITH NEC TABLE 250 -95, SHALL BEPROWDED IN ALL CONDUIT, RACEWAY, CABLE TRAY, ETC. ALL EQUIPMENT SHALL BL GROUNDED WITH AN EQUIPMENT GROUNDING CONDUCTOR CABLE (GREEN O� GREEN WITH YELLOW TRACER). THE EQUIPMENT GROUNDING CONDUCTOR SHALL BE RUN IN THE SAME ONDUIT AND RACEWAY AS THE CURRENT CARRYING CONDUCTORS, WITHOUT EXCPRON. STEEL (MAGNETIC) CONDUIT USED FOR MECHANICAL PROTECTION OF A GROUNDING CONDUCTOR SHALL BE SECURELY BONDED TO THAT CONDUrOR AT EACH END. ISOLATED GROUND CONDUCTORS SHALL BE INSULATED WIRE ROUTED FRM THE GROUND TERMINAL OF THE ISOLATED GROUND DEVICE (ORANGE) TO THE GROUND BUS OF THE PANELBOARD. WHERE THAT PANELBOARD IS NOT THE FIRST 0VERCURRENT EQUIPMENT AFTER A TRANSFORMER (SEPARATELY bqIVED SYSTEM), INSTALL AN ISOLATED GROUND BUS FOR THESE CONDUCTORS ,MID AN ISOLATED GROUND CONDUCTOR TO THE GROUND BUS OF THE DISTRBBUOIU PANELBOARD. SOLIDLY GROUND THE ISOLATED GROUND CONDUCTORS A 1THE MAIN BONDING JUMPER. PANELBOARD GENERAL: PANELBOARO CONSTRUCTION MAY BE USED FOR ALL OVERCURRJT DISTRIBUTION AND BRANCH CIRCUIT EQUIPMENT OF THE FOLLOWING SIZES: SINGLE SECTION WITH A MAIN BUS OF 1200A OR LESS MULTI- SECTIONS WITH A MAIN BUS OF 600A OR LESS. k MANUFACTURERS: ` CUTLER-HAMMER GENERAL ELECTRIC I E/GOULD, INC. SIEMENS- ALLIS, INC. _ . SQUARE D CO. CONSTRUCTION: PANELBOAROS SHALL HAVE GALVANIZED SHEET STEEL CABINETS THE MINIMUM SIZE SHALL BE 20 INCHES WIDE BY 5 -314 INCHES DEEP, FRONTS SHALL HAVE ADJUSTABLE TRIM CLAMPS AND DOORS WITH FLUSH LOCKS;AND KEYS, AND CONCEALED PIANO DOOR HINGES. EQUIP WITH AN INTERIOR CIRCUI i DIRECTORY FRAME, CARD AND CLEAR PLASTIC COVER. PROVIDE A BAKLt G RAY ENAMEL FINISH OVER A RUST INHIBITOR COATING. ENCLOSURES AND FRONT SHALL BE DESIGNED FOR SURFACE OR RECESS (OVERLAPPING FRONT) INSTALLA170N. AIC: PRO VIDE A MINIMUM AMPS IN ERRUP TING CAPACI TY OF 10, 000 AIC A T 208V AND 14, 000 AIC A T 480V OR GREA TER WHERE INDICA TED. FUSIBLE EQUPMENT SHALL BE RA EO 100, 000 AIC. BUSING: PROVIDE PANELBOARDS WITH COPPER OR TIN PLATED 4UMINUM B(XSES. MULTI - SECTION PANELS SHALL BE PROVIDED WITH SUB -FEED LUGS FOR., -- CONNECTION OF ALL SUB - SECTIONS PROVIDE A GROUND BUS IN EACH SECTION, AND PROVIDE A 100 PERCENT RATED NEUTRAL BUS IN EVERY PANELBOARD. SERVICE ENTRANCE. PROVIDE A UL SERVICE ENTRANCE LABEL ;FOR ALL PANELBOARDS SERVED BY A TRANSFORMER OR SEPARA TEL Y DERIVED ELECTRICAL SYSTEM. LIGHTING AND APPLIANCE PANELBOARDS. PROVIDE DEAD -FRONT SAFETY TYPE LIGHTING AND APPLIANCE PANELBOARDS AS INDICA TED. EQUIP WITH L?!L T -IPA' TYPE MOLDED CASE CIRCUIT BREAKERS. PANELBOAROS RATED UP TO ?25A SHALL BE CAPABLE OF EXCEPTING A 3P -100A CIRCUIT BREAKER AT ANY POjTION. WHERE ANY CIRCUIT BREAKER LARGER THAN 3P -100A IS REQUIRED, P VIDE A POWER DISTRIBU7ON PANELBOARD. ALL LIGHTING AND APPLIANCE PA LBOARDS SHALL HAVE DOORS r POWER DISTRIBUTION PANELBOARDS: PROVIDE DEAD -FRONT SAFETY E POWER DISTRIBUTION PANELBOARDS AS INDICATED. EQUIP NTH BOLT -IN CIRCkT BREAKERS OR FUSIBLE SWITCHES AS INDICATED. POWER DISTRIBUTION \ PANELBOAROS RATED 400A OR HIGHER SHALL ACCEPT 3P -150A (MINIMW) CIRCUIT BREAKERS AT ANY POSITION UNLESS LARGER BREAKERS OR FUSIBLE SOCHES ARE INDICATED. PROVIDE OVERALL DOORS FOR PANELBOARDS•CONTA /N /NG CPIUIT BREAKERS AND WHERE INDICATED FOR PANELBOARDS CONTAINING_- FUS18t SWITCHES. WHERE PANELBOARDS ARE INSTALLED OUTDOORS, PROVIDE A-MA 3R WEATHERPROOF EXTERIOR DOORS, GASKETING MATERIALS AND A DRIP HOD OVER THE TOP. MOLDED CASE BREAKERS: PROVIDE FACTORY- ASSEMBLED MOLDED CASECIRCUIT BREAKERS OF THE FRAME SIZES, AMPERES, POLES AND VOLTAGE AS INDCATED. BREAKERS SHALL HAVE PERMANENT THERMAL AND INSTANTANEOUS MAG TIC 7R /PS IN EACH POLE. CONSTRUCT WITH OVERCEN ER, TRIP-FREE TOGGLI TYPE , OPERA TING MECHANISMS WITH QUICK -MAKE, QUICK -BREAK ACTION AND POSITIVE HANDLE TRIP INDICATION. WHERE MULTIPLE POLE BREAKERS ARE INDICATED, PROVIDE WITH A COMMON TRIP SUCH THAT OVERLOAD ON ONE POLE WILL TRIP ALL POLES SIMUL TANEOUSL Y. CIRCUIT BREAKERS IN EXISTING PANELS -1w IF NEW CIRCUIT BREAKERS ARE REQUIRED IN THE EXISTING PANELBOARDS, THE ELECTRICAL CONTRACTOR SHALL PROVIDE NEW UNITS OF SAME AIC RATING AS EXISTWG UNITS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE CIRCUIT DESIGNATIONS TYPED ON THE DIRECTORY CARD ON THE INSIDE OF THE PANEL DOOR. FUSIBLE SWITCHES PROVIDE GROUP MOUNTED FUSIBLE SWITCH ASSEMBLIES RA ED FOR 30 TO 600 AMPERES AS INDICA TED. SW TCHES SHALL BE 3 -POLE, QUICK -MAKE, QUICK -BREAK TYPES OPERATED BY EXTERNAL HANDLES WHICH CAN BE PADLOCKED IN THE "ON" AND "OFF" POSITIONS SERIES RA TINGS: ALL SERIES RA TED COMPONENTS SHALL BE CLEARLY MARKED WITH A LABEL INDICATING THE DEVICE IS INSTALLED IN ACCORDANCE WITH PRESCRIBED UL RECOGNIZED SERIES CONNECTED CIRCUIT BREAKER COMBINA (IONS. NON- LINEAR LOADS PANELBOARDS CONNECTED TO TRANSFORMERS RATED AT K13 (OR HIGHER) OR WHERE INDICATED SHALL HAVE NEUTRAL BARS RA TED FOR 200 PERCENT CURRENT PROVIDE ADDITIONAL NEUTRAL LUGS FOR THE INCREASED CAPACITY NEUTRAL CONNECTIONS. FUSES GENERAL: PROVIDE FUSES OF THE TYPES, CLASSES AND CURRENT RATINGS AS IND/CAED. VOLTAGE RATINGS SHALL BE CONSISTENT WITH THE CIRCUITS ON WHICH THEY ARE USED. MANUFACTURERS. BUSSMAN DI V., COOPER INDUSTRIES, INC. GENERAL ELECTRIC GOULD, INC. LI TTLEFUSE, TRACER CO. RELIANCE FUSE DIV., FPE CO. CARTRIDGE FUSES. PROVIDE NON- RENEWABLE CARTRIDGE TYPE FUSES WHICH COMPLY WITH ANSI /IEEE STANDARD FU1. CLASS J FUSES CLASS L FUSES CLASS RK1 AND RK5 DUAL ELEMENT TIME DELAY FUSES CLASS RKl FAST ACTING FUSES CONTROL TRANSFORMERS AND BALLASTS: PROVIDE NON- RENEWABLE CARTRIDGE - TYPE FUSES, CLASS KTK -R, CURRENT LIMITING, COMPLYING WITH UL 198C, CLASS CC. PROVIDE BUSSMAN TYPE HEB (1 POLE) OR TYPE HEY (2 POLE), OR APPROVED EQUAL, FUSE HOLDERS FOR ALL CLASS KTK -R FUSES. APPL /CA TION: APPL Y FUSES AS INDICA TED ON THE DRAWINGS, AND IF NOT FULL Y DESCRIBED THERE, PROVIDE AS FOLLOWS. FUSES RATED 600 AMPERES OR LESS SHALL BE UL CLASS R OR CLASS J. FUSES RATED 601 AMPERES OR GREATER SHALL BE UL CLASS L, CURRENT LIMITING, BOL T -IN TYPE. FUSES RATED 60 AMPERES OR LESS AND PROTECTING 125 AND 250 VOLT MOLDED CASE CIRCUIT BREAKERS SHALL BE BUSSMAN LOW PEAK FUSES, TYPE LPN -R OR APPROVED EQUAL. FUSES RA TED 70 AMPERES TO 200 AMPERES AND PRO TEC TING 125 AND 250 VOLT MOLDED CASE CIRCUIT BREAKERS SHALL BE BUSSMAN LIM/ IRON FUSES, TYPE KTN- R OR APPROVED EQUAL. FUSES RATED 100 AMPERES OR LESS AND PROTECTING 277 AND 480 VOLT MOLDED CASE CIRCUIT BREAKERS SHALL BE BUSSMAN LOW PEAK FUSES, TYPE LPS -R OR APPROVED EQUAL. FUSES RATED 100 AMPERES TO 800 AMPERES AND PROTECTING 277 AND 480 VOLT MOLDED CASE CIRCUIT BREAKERS SHALL BE BUSSMAN LIMITRON FUSES, TYPE KTS -R OR APPROVED EQUAL. FUSES RATED 100 AMPERES OR LESS FOR MOTOR RUNNING PROTECTION SHALL BE DUAL - ELEMENT TIME DELAY TYPE FUSES. PROVIDE CLASS L TIME DELAY FUSES FOR MOTOR AND TRANSFORMER CIRCUITS AND FOR BOLTED PRESSURE SWITCHES PROVIDE CLASS L FAST ACTING FUSES FOR SERVICE PROTECTORS AND NON - INOUC 17 VE CIRCUI IS PROVIDE CLASS KTK -R FUSES FOR EXTERIOR POLE AND GROUP MOUNTED LIGHTING BALLASTS. MOTOR CONTROLLERS GENERA : PROVIDE A MOTOR CONTROLLER FOR EVERY MOTOR EXCEPT THOSE MOTORS WHICH ARE FURNISHED WITH CONTROL PANELS WHICH INCLUDE CONTROLLERS CONTROLLERS SHALL HAVE OVERLOAD PROTECTION FOR EACH PHASE AND SHALL INCLUDE A DISCONNECT DEVICE. MANUFACTURERS.• ALLEN - BRADLEY CO. CUTLER HAMMER GENERAL ELECTRIC l EIGOULD SIEMENS ENERGY ANO AUTOMATION SQUARE D CO. COMBINATION CONTROLLERS: PROVIDE COMBINATION CONTROLLERS CONSIS77NG OF A CONTROLLER AND A DISCONNECT SWITCH MOUNTED IN A COMMON ENCLOSURE OF THE TYPES, SIZES, RATING AND NEMA RATINGS AS INDICATED. EACH UNIT SHALL HAVE AN OPERATING HANDLE FOR THE DISCONNECT AND A DOOR INTERLOCK TO PREVENT THE DOOR FROM OPENING WHEN THE CONTROLLER IS ENERGIZED. PROVIDE A CONTROL POWER TRANSFORMER FOR 120 VOLT CONTROL POWER. TRANSFORMER SHALL HAVE TWO PRIMARY AND ONE SECONDARY FUSES, A GROUNDED RTER SHALL SIZED REQUIRED AND ANY EXTERNAL CONTROL DEVIL S (MINIMUM SIZE 7 5 POWER VA). THE STARTER PROVIDE A 3 PHASE VOLTAGE FAILURE AND REVERSE PHASE RELAY FOR ALL MAGNETIC STARTERS SERVING MOTORS OF 5 HP AND LARGER. PROVIDE A TIMING RELAY FOR REVERSING AND TWO -SPEED STARTERS TO PROVIDE AUTOMATIC DECELERATION BEFORE REVERSING OR GOING FROM HIGH TO LOW SPEED. PROVIDE FUSIBLE SWI TCH ASSEMBLIES UNLESS OTHERWISE INDICATED ON THE ORAWNGS SWITCH SHALL BE QUICK -MAKE, QUICK -BREAK TYPE NTH EXTERNAL HANDLE WHICH CAN BE PADLOCKED IN THE "ON" AND "OFF " POSITIONS. FUSES SHALL BE CLASS R. MANUAL MOTOR STARTERS: PROVIDE SINGLE -PHASE OR MULTIPLE-PHASE MANUAL MOTOR STARTERS WHERE INDICATED, OF THE SIZES AND RATINGS AS REQUIRED. EQUIP WITH A MANUALLY OPERATED QUICK -MAKE, QUICK -BREAK TOGGLE MECHANISM AND NTH A ONE -PIECE MELTING ALLOY TYPE THERMAL UNIT. EACH UNIT SHALL HAVE A GREEN PILOT LIGHT SWITCH SHALL BE CAPABLE OF BEING PADLOCKED "OFF" IN FINISHED SPACES PROVIDE A FLUSH UNIT WITH A STAINLESS STEEL COVERPLATE, PILOT LIGHT AND WITHOUT THE PADLOCK OPTION. RELAYS, CONTACTORS AND CONTROLS GENERAL: PROVIDE RELAYS, CONTACTORS, TIMECLOCKS, PHOTOCELLS, PUSHBUTTONS, SELECTOR SWITCHES ANO PILOT LIGHTS AS INDICATED ON THE . DRAWINGS AS REQUIRED IN THESE SPECIFICA TIONS OR AS REQUIRED BY THE INSTALLA TION. MANUFACTURERS: RELAYS ANO CONTACTORS: ALLEN - BRADLEY CO. ASCO CUTLER HAMMER GENERAL ELECTRIC I E/GOULD SIEMENS ENERGY AND AUTOMATIC SQUARE 0 ZENITH PUSHBUTTONS SELECTOR SWITCHES AND PILOT LIGHTS: ALLEN - BRADLEY CUTLER- HAMMER GENERAL ELECTRIC I TEIGOULO SIEMENS ENERGY AND AUTOMATON SQUARE D RELAYS: PROVIDE RELAYS AND CONTROL RELAYS AS SHOWN OR SCHEDULED ON THESE DRAWINGS OR AS REQUIRED BY THE INSTALLATION. PROVIDE THE NUMBER OF CONTACTS AND TYPE OF CONTACTS WITH THE VOLTAGE AND AMPERAGE REQUIRED FOR COMPLETE AND OPERATING SYSTEMS. TIMING RELAY SHALL BE PLUG -IN, SOLO- STATE, ADJUSTABLE DELAY UNIT COMPLETE WITH SOCKET AND RESTRAINING STRAP. CONTACTORS: PROVIDE CONTACTORS AS SHOWN OR SCHEDULED ON THESE DRAWINGS. PROVIDE THE NUMBER AND TYPES OF CONTACTS WITH THE VOLTAGE CONTACTRS SHALL BE To CONTROL THE AND AMPERAGE REQUI FOR FULL AMPERAGE TODTHE TYPE OF LOAD LOA A TED (L/GHRNG, HEA T MOTORED ETC.). MANUAL CONTROLS.- PUSHBUTTONS, SELECTOR SW TCHES AND PIL 0 T LIGHTS SHALL BE HEAVY DUTY, INDUSTRIAL QUALITY DEVICES. THEY SHALL MOUNT IN 30.5 MM HOLES. PROVIDE CONTACT BLOCKS AND CONFIGURATIONS AS INDICATED. PUSHBUTTONS SHALL BE MOMENTARY CONTACT /BREAK WITH SPRING RETURN AND, UNLESS NOTED OTHERWISE, FLUSH HEADS. SELECTOR SWITCHES SHALL BE MAINTAINED CONTACT WITH THE NUMBER OF POSI71ONS INDICATED. KEY OPERATED SWITCHES SHALL BE MOMENTARY CONTACT WITH SPRING RETURN TO CENTER, AND KEY WITHDRAWAL SHALL BE FROM THE CEN ER POSITION ONLY LEGEND PLATES SHALL BE PROVIDED WITH EACH PUSHBUTTON AND SELECTOR SWITCH TO IDENTIFY THE PURPOSE OF EACH DEVICE. PILOT LIGHTS SHALL BE OF THE COLOR INDICATED AND THE VOLTAGE REQUIRED, AND SHALL ALSO HAVE A LEGEND PLATE OR CUSTOM ENGRAVED PLASTIC LAMINAE NAMEPLATE. IGH TING F/XTUR GENERAL: PROVIDE LIGHTING FIXTURES OF SIZES, TYPES AND RATINGS INDICA ED COMPLETE WITH HOUSINGS, LAMPS, LAMP HOLDERS, REFLECTORS, BALLASTS, STARERS AND WIRING. MANUFACTURERS: THE MANUFACTURERS' MODEL NUMBERS SHOWN ON THE SCHEDULE ARE INDICATIVE OF THE QUALITY AND PERFORMANCE REQUIRED. OTHER MANUFACTURERS ARE ACCEPTABLE IF OF SIMILAR STYLE, MATERIALS, DESIGN AND PERFORMANCE. TROFFER FIXTURES TROFFERS SHALL BE LAY -IN, FANGED OR PLASTER FRAME TRIM AS REQUIRED. THE LENS SHALL BE MOUNTED IN A METAL DOOR FRAME. LENSES SHALL BE 100 PERCENT UV STABILIZED VIRGIN ACRYLIC PLASTIC OF PRISMATIC DESIGN AND SHALL BE 0.125 INCHES NOMINAL THICKNESS (7.8 OZ PER SQUARE FOOT). ALL LAMPS SHALL MOUNT IN THE SAME PLANE- AND SHALL BE A MINIMUM OF 2 INCHES FROM THE LENS LIGHT LEAKS AROUND THE DOOR FRAME SHALL NOT BE PERMITTED. EXIT SIGNS PROVIDE SURFACE, WALL OR CEILING MOUNTED EXIT SIGNS WITH DIRECTIONAL ARROWS AS INOICA ED OR REQUIRED. FIXTURES SHALL BE WHITE STENCIL FACE(S) WITH GREEN LETTERS AND DIRECT70NAL ARROWS. LETTERING SHALL BE 6 INCHES HIGH NTH A 314 INCH STROKE. LAMPS: PROVIDE EACH FIXTURE COMPLETE WITH THE LAMPS INDICATED. FLUORESCENT LAMPS SHALL HAVE A 3500 DEGREE COLOR TEMPERATURE. INCANDESCENT LAMPS SHALL BE RATED FOR 130 VOLTS. QUARTZ LAMPS SHALL BE OF THE TUNGSTEN- HALOGEN TYPE. SUPPORT.- SURFACE MOUNED FIXTURES GREATER THAN 2 FEET IN LENGTH SHALL BE SUPPORTED A T TWO POINTS. RECESSED AND SEMI- RECESSED FIXTURES MAY BE SUPPORTED FROM SUSPENDED CEILING SUPPORT SYSTEM IF THE CEILING SYSTEM SUPPORT RODS OR WIRES ARE INSTALLED WITH A MINIMUM OF FOUR RODS OR WIRES PER FIXTURE AND LOCATED NOT MORE THAN 6 INCHES FROM THE FIXTURE CORNERS. DO NOT SUPPORT FIXTURES BY CEILING ACOUSTICAL PANELS. TROFFERS SHALL BE SECURELY FASTENED TO THE CEILING FRAMING MEMBERS BY MECHANICAL MEANS OR SHALL HAVE FOUR STEEL WIRES OR SAFETY CHAINS FROM EACH CORNER OF THE FIXTURE ATTACHED TO THE STRUCTURE OF THE BUILDING. BAT Rl S PROVIDE CHARGING POWER TO ALL BATTERY RESERVE EMERGENCY LIGHTING EQUIPMENT FROM THE DATE OF RECEIPT FROM THE MANUFACTURER OR DISTRIBUTOR TO MAINTAIN THE BATTERIES. BATTERIES SHALL NOT BE STORED WITHOUT POWER NOR ALLOWED TO REPEATEDLY CHARGE AND DISCHARGE DURING CONSTRUCTION. AFTER EMERGENCY LIGHTING UNITS HAVE BEEN INSTALLED AND THE BUILDING CIRCUI IS HA VE BEEN ENERGIZED WI TH NORMAL POWER, APPL Y ANO INTERRUPT ELECTRICAL ENERGY TO DEMONSTRATE PROPER OPERATION. FL ESTRONIC SYSTEMS PROVISIONS GENERAL: PROVIDE A SEPARATE CONDUIT ROUGH -IN SYSTEM FOR EACH OF THE FOLLOWING SYSTEMS: TELEPHONE SYSTEM TELEVISION SYSTEM CONDUIT AND RACEWAY.• A RACEWAY SYSTEM SHALL BE PROVIDED FROM OUTLET BOXES TO ABOVE ACCESSIBLE, LAY -IN CEILINGS. CABLES MAY BE INSTALLED EXPOSED ABOVE ACCESSIBLE CEILINGS PROVIDE CONDUIT IN WALLS, FLOORS AND ABOVE DRYWALL, PLASTER OR OTHER NON- ACCESSIBLE CEILINGS. PROVIDE SLEEVES IHROUGH FIRE WALLS OR OTHER WALLS WHICH EXTEND TO THE STRUCTURE AND THROUGH FLOORS AS REQUIRED TO ROUTE EXPOSED CABLES TO THE TERMINAL EQUIPMENT. THE MINIMUM CONDUIT SIZE SHALL BE 314 INCH. PROVIDE WALL, FLOOR OR CEILING OUTLET BOXES FOR EACH SYSTEM AS INDICA TED. PULL WIRES: ALL EMPTY CONDUIT SHALL BE PROVIDED WITH A #14 AWG GALVANIZED STEEL PULL WIRE OR A NYLON PULL CORD OF EQUIVALENT STRENGTH. COVERPLATES: PROVIDE BLANK COVERPLATES ON ALL UNUSED OUTLET BOXES. COVERPLA TES SHALL MA TCH THOSE SPECIFIED FOR WIRING DEVICES. DATA CABLES CATEGORY 5 CABLE SHALL BE A 22 AWG, 4 PAIR UNSHIELDED CABLE WHICH HAS TRANSMISSION CHARACTERISTICS SUITABLE FOR DATA RATES ABOVE 16MBPS. CABLE SHALL MEET THE REQUIREMENTS FOR CA EGORY 5 CABLE DEFINED BY E/A/T7A. WALL OUTLETS SHALL BE RJ45, CATEGORY 5 MODULAR JACK TYPE OUTLETS. DA TA CABLES SHALL BE INSTALLED IN ACCORDANCE WI TH THE RECOMMENDA TIONS OF E /AIRA FOR STRUCTURED CABLING. TERMINATE ALL PAIRS OF CABLE. LIMIT HORIZONTAL CABLING TO 300 FEET TOTAL LENGTH. DO NOT TIGHTLY CINCH CABLE BUNDLES AND OTHERWISE AVOID STRESS OR TENSION ON THE CABLES. TERM/NA E CABLES ON 8 POSI RON JACK PIN /PAIR ASSIGNMENT TO MA TCH EXISTING WIRING. CONCEAL ALL WIRING AND RACEWAYS EXCEPT IN UNFINISHED SPACES. 'PROV/DE WIRING OF ONE OF THE FOLLOWING: OPEN CABLE WITHOUT A CONDUIT SYSTEM WHERE ABOVE ACCESSIBLE CEILING AREA. OPEN PLENUM CABLE WITHOUT A CONDUIT SYSTEM WHERE ABOVE ACCESSIBLE CEILING AREAS. CABLE INSTALLED IN AN EMT CONDUIT SYSTEM. IN ACCESSIBLE CEILING AREAS THE ELECTRICAL CONTRACTOR MAY INSTALL WIRING OPEN ABOVE CEILING SYSTEM AS DIRECTED FOR EXPOSED CABLES. IN ACCESSIBLE CEILINGS USED FOR ENVIRONMENTAL AIR RETURN OR SUPPLY THE ELECTRICAL CONTRACTOR MAY INSTALL CABLES IN METAL CONDUIT SYSTEM OR USE UL LISTED PLENUM CABLE. COORDINATE AVAILABILITY OF UL LISTED PLENUM CABLE WHICH WILL MEET SYSTEM MANUFACTURER REQUIREMENTS BEFORE INSTALLATION. TEST ALL CABLES AND ERMINA 77ONS TO 10OMHZ, RECORD TEST DATA AND PROVIDE TO OWNER. BSA DESIGN 6810 N SHADELAND AVE INDIANAPOLIS INDIANA 46220.4287 317.849.7878 PH 317.849.2288 Fx ,,,, S, \ % �i. , 3 ~ r� No. ° ' tt% Q 13815 STATE OF / �0\ yam,,, ._ ._ ,���, N �t I - �� MOORS ENGINEER A PROFESSIONAL CORPORATIOT 9245 N. Meridian Street, Suite 10. Indianapolis, Indiana 46260 -181, 317.848.5045 PH 317.848.2765 Fld St. vincest Carmel Hosph 13500111. Meridian street P.O. Box 1805 Carmel; Indiana 46032 CARMEL MEDICAL BUILDING No. 1 SUITE 315/355 Carmel, Indiana ELECTRICAL SPECIFICATIONS SCALE NONE CLIENT NO. DATE 9 -29 -97 COMMISSION ' COORD BKS DRAWN BKS APPROVED TMW