ANCHOR TO STRUCTURE
ABOVE AS REQUIRED —
CONTINUOUS METAL STUD
SEAL AROUND ALL
PENETRATIONS
3 1/2" THERMAL
BLANKET INSULATION —
EXISTING CEILING LINE
METAL STUDS
HOLLOW METAL FRAME
AND SCW DOOR
AS REQUIRED. DOOR
AND FRAME SHALL BE
ONE HOUR CONST. PROVIDE EXIT
DEVICE, BUTTS, CLOSER, ETC. —
3 5/8" METAL STUDS
EXISTING FLOOR LINE
CONTINUOUS METAL STUD
PLATE FRICTION FIT
SEALANT ® FLOOR AND
UNDERSIDE OF SLAB
FOR DUSTPROOF
PROTECTION
EXISTING CEILING SHALL BE
MODIFIED AS REQUIRED TO
ALLOW INSTALLATION OF DUST
PARTITION AND TO PROVIDE
CONTINUOUS CEILING SYSTEM.
5/8" TYPE X FIRE RATED
GYPSUM BOARD EACH SIDE
(TAPE ALL JOINTS)
PROVIDE SEAL ® HEAD, JAMB,
AND FLOOR.
SEALANT ® FLOOR
FOR DUSTPROOF
PROTECTION
01 - TEMPORARY DUST PARTITION
SCALE 3/4"- T -0"
O PLAN NOTES
GENERAL PLAN NOTES
1.
ALIGN CENTER OF NEW STUD WALL WITH CENTER OF WINDOW MULLION
A.
ALL WALLS SHALL BE TYPE 'A' UNLESS NOTED OTHERWISE.
2.
ALIGN FACE OF NEW STUD WALL WITH FACE OF EXISTING WALL
B.
SHADED WALLS INDICATE EXISTING CONSTRUCTION.
3.
PROVIDE TEMPORARY DUST PARTITION AS INDICATED ON PLAN.
C.
ALL DIMENSIONS ARE TAKEN TO THE FACE OF METAL STUDS OR TO THE FACE OF EXISTING SURFACES UNLESS
NOTED OTHERWISE.
4.
42 "GRAB BAR LIKE BOBRICK B- 6206.99. MOUNT AT 36" A.F.F.
D.
CONSTRUCTION AND INSTALLATION SHALL CONFORM TO ALL STATE AND LOCAL ORDINANCES, CODES, ETC.
5.
36" GRAB BAR LIKE BOBRICK B- 6206.99. MOUNT AT 36" A.F.F.
E.
VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ARCHITECT
6.
MIRROR (30 "W X 42" H) LIKE BOBRICK B -165 SERIES. MOUNT AT 82" TO TOP
IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING WITH WORK.
7.
TOILET PAPER DISPENSER LIKE BOBRICK B -6867 SERIES. MOUNT AT 26" A.F.F. TO C.L.
F.
THE CONTRACTOR SHALL PROTECT THE EXISTING ELEVATOR FINISHES IF THE ELEVATORS ARE
USED FOR MOVEMENT OF MATERIAL OR EQUIPMENT INTO THE BUILDING. ANY DAMAGE SHALL BE REPAIRED/
8.
PROVIDE 10 COAT HOOKS AT 4" O.C. ON PLASTIC LAMINATE COVERED PLYWOOD 6" X 40 ".
REPLACED AT THE OWNERS DISCRETION, WITH NO COST TO THE OWNER.
MOUNT CENTER OF HOOK AT 72" A.F.F.
9.
PROVIDE 12" DEEP PLASTIC LAMINATE SHELF WITH 2" FASCIA. MOUNT AT 5' -9" A.F.F.
G.
ALL HOLES OR OPENINGS IN WALLS SHALL BE PATCHED AND FINISHED TO MATCH SURROUNDING AREAS. THIS
PROVIDE COAT HANGING ROD AT 5' -4" A.F.F. TO CENTER
SHALL INCLUDE OPENINGS FROM THE REMOVAL OF PIPES, JUNCTION BOXES, WALL MOUNTED EQUIPMENT, ETC.
ALL ABANDONED JUNCTION BOXES SHALL BE REMOVED, COORDINATE WITH ELECTRICAL DRAWINGS.
10.
PROVIDE 1 "X OAK TRIM AROUND PERIMETER OF ROOM. TOP SHALL BE AT 7' -2" A.F.F.
REFER TO CASEWORK ELEVATIONS. TRIM SHALL BE 3" IN HEIGHT
H.
THE CONTRACTOR SHALL PROTECT THE EXISTING FINISHES IN THE CORRIDOR ROUTES USED TO GET CONSTRUCTION
MATERIALS TO THE PROJECT AREA. ANY DAMAGES SHALL BE REPAIRED /REPLACED AT THE OWNER'S DISCRETION,
11
PROVIDE FIVE 12" DEEP PLASTIC LAMINATE COVERED SHELVES ON ADJUSTABLE WALL BRACKETS
WITH NO COST TO THE OWNER.
36" O.C. PROVIDE WALL BLOCKING AS REQUIRED.
12. PROVIDE HOOK ON WALL LIKE HEWI MODEL 520.60.1. MOUNT AT 72" A.F.F. TO C.L.
13. PROVIDE HOOK ON BACK OF DOOR LIKE HEWI MODEL 520.60.1. MOUNT AT 72" A.F.F. TO C.L.
14. PROVIDE SIX 8" DEEP PLASTIC LAMINATE COVERED SHELVES ON ADJUSTABLE WALL BRACKETS
36" O.C. PROVIDE WALL BLOCKING AS ,REQUIRED.
15. PROVIDE MOP AND BROOM HOLDER /SHELF LIKE BOBRICK B -224 X 30. MOUNT AT 66" A.F.F. TO C.L.
16. WALL SCONCE LOCATION. MOUNT CENTER AT 6' -0" A.F.F.
17. PROVIDE 8" DEEP X 32" WIDE PLASTIC LAMINATE SHELF AT 4' -9" A.F.F.
18. REFINISH INTERIOR FACE OF EXISTING DOOR TO MATCH NEW STAIN AND FINISH WITHIN THE SUITE. REFINISH EXTERIOR
FACE TO MATCH EXISTING DOORS IN CORRIDOR. REPLACE KNOB WITH LEVER HANDSET. IF EXISTING IS NOT ADAPTABLE
PROVIDE NEW LOCKSET.
19. PROVIDE 5 COAT HOOKS AT 4" O.C. ON PLASTIC LAMINATE COVERED PLYWOOD 6" x 20 ".
MOUNT CENTER OF HOOK AT 72" A.F.F.
20. PROVIDE PAPER TOWEL DISPENSER LIKE BOBRICK B -262. MOUNT WITH DISPENSER SLOT AT 44" A.F.F.
21. EXISTING FIRE EXTINGUISHER CABINET.
22. CLOSE WINDOW BLINDS BEFORE SETTING NEW STUD WALL.
23. REFINISH OR REPLACE AND STAIN OAK WINDOW SILL TO MATCH NEW OAK FINISH.
(TYPICAL AT ALL WINDOWS)
24. PROVIDE STUD WALL BELOW COUNTERTOP. REFER TO CASEWORK ELEVATIONS AND SECTIONS FOR WALL t OCATIONS.
WALL TYPES
A 3 5/8" METAL STUDS AT 16" O.C.
WITH ONE LAYER 5/8" GYPSUM
WALL BOARD ON EACH SIDE.
CONTINUE STUDS AND GYPSUM
BOARD TO STRUCTURE ABOVE
PROVIDE FULL HEIGHT ACOUSTICAL
BATT INSULATION.
3 5/8" METAL STUDS AT 16" O.C.
B WITH ONE LAYER 5/8" GYPSUM WALL
BOARD ON EACH SIDE. CONTINUE
STUDS AND GYPSUM BOARD 6" ABOVE
CEILING. PROVIDE ACOUSTICAL BATT
INSULATION
C 3 5/8" METAL STUDS AT 16" O.C.
WITH ONE LAYER 5/8" GYPSUM
WALL BOARD ON ONNE SIDE.
PROVIDE BATT INSULATION
3 5/8" METAL STUDS AT 16" O.C.
D '> WITH TWO LAYERS 5/8" TYPE "X"
GYPSUM WALL BOARD ON EACH SIDE.
CONTINUE STUDS AND GYPSUM
BOARD TO STRUCTURE ABOVE
PROVIDE FULL HEIGHT ACOUSTICAL
BATT INSULATION. PROVIDE TWO
HOUR RATING.
2 1/2" W X 1 1/2" D "C -H" SHAPED 25 GAUGE
E GALVANIZED STEEL STUDS AT 24" O.C. WITH
1" GYPSUM WALLBOARD LINER PANELS
0 INSERTED IN "H" SHAPED SECTION OF STUDS
(UNFINISHED SIDE) AND ONE LAYER 5/8"
GYPSUM WALLBOARD ON "C" SHAPED (EXPOSED)
SIDE (GYPSUM ASSOCIATION WP 7008 ONE HOUR)
ARCHITECTURAL SYMBOLS
AEXISTING COLUMN
ELEVATION SYMBOL
Al -05
ELEVATION NUMBER
SHEET NUMBER
°o DOOR NUMBER
WALL TYPE DESIGNATION
Q I WALL TYPE
SUITE 315
CN
�I
�I
o'
w t 10 23
Q
- - - -- - -0 0 � - -10 2,'
f
0
M
i
8 9
STAFF
LOUNGE
115
14
PARTIAL THIRD FLOOR ARCHITECTURAL PLAN
SCALE: 1/8" - T -0"
NOTE:
PROVIDE 1 HOUR FLOOR RATING ON FLOOR AND STRUCTURE BELOW THE AREA
ENCLOSED WITH THE ONE HOUR WALL CONSTRUCTION. ANY BEAMS OR JOISTS
THAT ARE SPRAYED AND EXTEND BEYOND THE RATED WALLS SHALL BE SPRAYED
ALL THE WAY BACK TO A SUPPORTING BEAM OR COLUMN. MEET U.L. TESTS G701,
D739. COORDINATE WORK IN OCCUPIED SUITE WITH ST. VINCENT AND TENANT.
SUITE
u' �1fii
------- - - - - -- -
20
!CEDURE J
355
17;:18;
WAITING ROOM NAME DESIGNATION
100 ROOM NUMBER DESIGNATION
OPLAN NOTE
OEQUIPMENT NOTE
ONE HOUR RATING PARTIAL THIRD FLOOR DIMENSION PLAN
SCALE 1/8" . T -0"
BSA DESIGN 6810 N SHADELAND AVE
INDIANAPOLIS INDIANA 46220.4287
317.849.7878 PH 317.849.2288 Fx
```�. •• •....... . �. E. SCIy,Q0
S TE�� �F'.�G � S Tf' ** n
- 4069 - - 4201 •
-
STATE OF •; STATE OF •�
' •'• 0ND I A N P .•• •. //VD .•
�* gRCH I TE�� ��•. .,., -4RCH I TE�� %%\
,,' "Miu1N�`� �I'Wfillnoo,
ST. VINCENT CARMEL HOSPITAL
13500 N. Meridian Street
P.O. Box 1903
Carmel, Indiana 46032
CARMEL
MEDICAL
BUILDING
No. 1
SUITE 315/ 355
Carmel, Indiana
THIRD FLOOR
ARCHITECTURAL &
DIMENSION PLAN
SCALE 1/8" = 1' -0" CLIENT NO, 076000
DATE 29 SEPT 1997 COMMISSION 076146
COORD
DRAWN J ES
APPROVED Al