Loading...
HomeMy WebLinkAbout1218.97.20N O Ln 0 N N LL ti w i Ln Ln 0 ti 0 i U W ^�1 ___I W t ELECTRICAL SPECIFICA TIONS CONTINUED MUSIC DISTRIBUTION SYSTEM GENERAL: PROVIDE A MUSIC DISTRIBU77ON SYSTEM WITH ALL FEATURES, FUNCTIONS AND COMPONENTS SPECIFIED HEREIN AND /OR REQUIRED ON THE DRAWINGS SYSTEMS PROVIDED PER THESE SPECIFICATIONS INCLUDE THE FOLLOWING COMPONENTS.- EQUIPMENT RACK POWER AMPLIFIER CASSETTE TAPE PLAYER COMPCT DISK PL YER LOUDSPEAKERS VOLUME CONTROLS WIRE AND CABLE CODE COMPLIANCE. PROVIDE WORK COMPLYING WITH APPLICABLE REQUIREMENTS OF NFPA 70 NATIONAL ELECTRICAL CODE". EIA COMPLIANCE: COMPLY WITH THE FOLLOWING ELECTRONICS INSTITUTE ASSOCIATION STANDARDS: SOUND SYSTEMS, EIA -150 LOUDSPEAKER, DYNAMIC MAGNETIC STRUCTURES, AND IMPEDANCE, EIA -299A RACKS, PANELS AND ASSOCIATED EQUIPMENT, EIA -310A AMPLIFIERS FOR SOUND EQUIPMENT, SE -101A SPEAKERS FOR SOUND EQUIPMENT, SE -103 UL COMPLIANCE. COMPLY WITH REQUIREMENTS OF UL50. MANUFACTURERS. A TLAS/SOUNDOLIER BOGEN CORP. DUKANE CORP. RAULAND -BORG CORP. UNI VERSI TY SOUND EQUIPMENT LIST- PROVIDE EQUIPMENT FROM AN APPROVAL MANUFACTURER EQUAL TO THE FOLLOWING: EQUIPMENT RACK SOUNDOL/ER 300 POWER SUPPL Y DUKANE 17A365 MIXER /POWER AMPLIFIER DUKANE 1A 1635 CASSETTE TAPE DECK (RACK MOUNT) DUKANE 1OA1901438 -725 MUL77 -00 PLAYER (RACK MOUNT) DUKANE CH6000R 1438 -726 RECESSED SPEAKERS SOUNDOL/ER F072W/CS95- 8NS181 -8 VOLUME CONTROL SOUNDOL/ER A T -10 SYSTEM WIRING MATERIALS AND REQUIREMENTS ALL WIRING SHALL BE INSTALLED AS DIRECTED BY MANUFACTURERS SHOP DRAWINGS COORDINATE ALL CABLE REQUIREMENTS WITH MANUFACTURER. ALL CABLES SHALL BE UL LISTED FOR THEIR USE. CONCEAL ALL WIRING ANO RACEWAYS EXCEPT IN UNFINISHED SPACES. PROVIDE WIRING OF ONE OF THE FOLLOWING: OPEN CABLE WITHOUT A CONDUIT SYSTEM WHERE ABOVE ACCESSIBLE CEILING AREA. OPEN PLENUM CABLE WITHOUT A CONDUIT SYSTEM WHERE ABOVE ACCESSIBLE CEILING AREAS CABLE INSTALLED IN AN EMT CONDUIT SYSTEM, INSTALLA T70NS WITH STRANDED WIRE COMPLY WITH THE FOLLOWING: PROVIDE WIRE AND CABLE IN ACCORDANCE WITH REQUIREMENTS OF MANUFA C 7URER. PROVIDE MUL 77CONDUCTOR CABLES FOR WIRE SIZES SMALLER THAN AWG #14. IN ACCESSIBLE CEILING AREAS 7HE ELECTRICAL CONTRACTOR MAY INSTALL WIRING OPEN ABOVE CEILING SYSTEM AS DIRECTED FOR EXPOSED CABLES IN ACCESSIBLE CEILINGS USED FOR ENVIRONMENTAL AIR RETURN OR SUPPLY THE ELECTRICAL CONTRACTOR MAY INSTALL CABLES IN METAL CONDUIT SYSTEM OR USE UL LISTED PLENUM CABLE. COORDINA7E AVAILABILITY OF UL LISTED PLENUM CABLE WHICH WILL MEET SYSTEM MANUFACTURER REQUIREMENTS BEFORE INSTALLATION. CTRICAL DEMOLITION WORK GENERA : THIS CONTRACTOR SHALL DEMOLISH THE ELECTRICAL SYSTEMS IN THE EXISTING FACILITY AS SHOWN ON THE DRAWINGS, AS REQUIRED BY THE N07ES OR AS REQUIRED TO ACCOMMODATE NEW CONSTRUCTION. ALL EQUIPMENT, CONDUIT, WIRING, FIXTURES, ETC. WHICH ARE NOT TO BE REUSED` SHALL BE REMOVED FROM THE PREMISES AS THEY ARE REMOVEO EXCEPT THA T THE CONTRACTOR SHALL NOT REMOVE FROM THE PREMISES ANY EQUIPMENT THAT MAY HAVE MAINTENANCE VALUE TO THE 0WNER WITHOUT PERMISSION OF THE OWNER. SALVAGED MA 7ER/ALS TO BE TURNED OVER TO THE OWNER SHALL BE CAREFULL Y REMOVED, CLEANED AND STORED. INSPECTION: PRIOR TO COMMENCEMENT OF SELECTIVE DEMOLI T70N WORK, INSPECT AREAS IN WHICH WORK WILL BE PERFORMED. PHOTOGRAPH EXISTING CONDITIONS TO STRUC7URE SURFACES, EQUIPMENT OR TO SURROUNDING PROPERTIES WHICH COULD BE MISCONSTRUED AS DAMAGE RESULTING FROM SELECTIVE DEMOLITION WORK, AND FILE KITH THE OWNERS REPRESEN TA 77VE PRIOR TO S TAR 77NG WORK. PREPARATION. PROVIDE TEMPORARY BARRICADES AND OTHER FORMS OF PROTECTION AS REQUIRED TO PROTECT THE OWNERS PERSONNEL AND THE GENERAL PUBLIC FROM INJURY DUE TO SELECTIVE DEMOLITION WORK. MAINTAIN EXISTING UTILITIES WHICH ARE TO REMAIN, KEEP THEM IN SERVICE, AND PR07ECT THEM AGAINST DAMAGE DURING OEMOL177ON AND CONSTRUCTION. PROVIDE INTERIOR AND EXTERIOR SHORING, BRACING OR SUPPORT TO PREVENT MOVEMENT, SETTLEMENT OR COLLAPSE OF 774E STRUCTURE TO BE DEMOLISHED AND ADJACENT FACILITIES WHICH ARE TO REMAIN. COVER AND PROTECT FURNITURE, EQUIPMENT AND FIXTURES WHICH ARE TO REMAIN FROM SOILING OR DAMAGE DURING DEMOLI TION WORK IN THOSE AREAS FROM WHICH SUCH I TEMS HA VE NOT BEEN REMOVED. DEMOLITION: PROTECT ADJACENT MATERIALS INOICA TED TO REMAIN. LOCATE, IDENTIFY AND PROTECT ELECTRICAL SERVICES PASSING THROUGH THE DEMOLITION AREA AND SERVING OTHER AREAS OUTSIDE THE DEMOLITION LIMITS. MAINTAIN EXISTING ELECTRICAL SERVICES AND FEEDERS TO OCCUPIED AREAS AND OPERA77ONAL FACIL177ES PERFORM SELECTIVE DEMOLITION WORK IN A SYSTEMA 77C MANNER. USE SUCH METHODS AS REQUIRED TO COMPLETE WORK INOICA TED ON THE DRAWINGS IN ACCORDANCE WI TH GOVERNING REGULA TIONS. HAZARDOUS MATERIALS. IF HAZARDOUS MATERIALS ARE ENCOUN7ERED OR BELIEVED TO BE ENCOUNTERED DURING DEMOLITION OPERATIONS, THE CONTRACTOR SHALL STOP WORK AT THAT PARTICULAR LOCATION AND NOT /FY THE OWNER OF THE HAZARDOUS MATER /AL. THE CONTRACTOR SHALL CONTINUE WORK AFTER REMOVAL OF HAZARDOUS MATERIALS. DISPOSAL: REMOVE DEBRIS, RUBBISH AND OTHER MA TERIALS RESUL TING FROM DEMOLITION OPERA TIONS FROM THE BUILDING SI FE TRANSPORT AND LEGALLY DISPOSE OF MA7ERIALS OFF SITE. BURNING OF REMOVED MATERIALS IS NOT PERMITTED ON THE PROJECT S1 7E BALLASTS AND LAMPS: EXIS77NG BALLASTS, HID AND FLUORESCENT LAMPS MAY CONTAIN PCB, MERCURY AND OTHER HAZARDOUS MATERIALS. THESE COMPONENTS SHALL BE RECYCLED WHERE POSSIBLE AND NON- RECYCLED MA7FR/ALS SHALL BE DEPOSITED AT AN EPA APPROVED HAZARDOUS WASTE LANDFILL. THE DISPOSAL AND MANIFEST OF DISPOSAL OF THESE COMPONENTS SHALL BE CER77FIED. THE COMPONENTS SHALL NOT BE DEPOSITED IN GENERAL WASTE REMOVAL OUMPSTERS. THE RESPONSIBLE PARTY SHALL FURNISH TRANSPORT CONTAINERS AT THE 10851 IF FOR STORAGE OF COMPONENTS CLEAN -UP AND REPAIR: UPON COMPLET70N OF ELECTRICAL DEMOLITION WORK, REMOVE TOOLS, EQUIPMENT AND DEMOLISHED MA 7FR/ALS FROM THE SITE REMOVE PROTEC77ONS AND LEAVE INTERIOR AREAS BROOM CLEAN. REPAIR DEMOL/ TION PREFORMED IN EXCESS OF THA T REQUIRED. RETURN STRUCTURES AND SURFACES WHICH ARE TO REMAIN TO COND177ONS EXISTING PRIOR TO COMMENCEMENT OF SELECTIVE DEMOLI770N WORK. REPAIR ADJACENT CONSTRUCTION OR SURFACES SOILED OR DAMAGED BY SELECTIVE DEMOLITION WORK. END OF SPEC BSA DESIGN 6810 N SHADELAND AVE INDIANAPOLIS INDIANA 46220.4287 317.849.7878 PH 317.849.2288 Fx F10 No. e 13815 WY STATE OF MOORS ENGINEERS A PROFESSIONAL CORPORATION 9245 N. Meridian Street, Suite 105 Indianapolis, Indiana 46260 -1812 317.848.5045 PH 317.848.2765 FX St. Vinceut Carmel Hospital 13600 N. Meridian Street P.O. Boz 1903 Camel lnd/ana 48082 CARMEL MEDICAL BUILDING No. 1 SUITE 315/355 Carmel, Indiana ELECTRICAL SPECIFICATIONS SCALE NONE CLIENT NO. DATE 9 -29 -97 COMMISSION 97055 COORD BKS DRAWN BKS E7 APPROVED TMW