HomeMy WebLinkAbout1218.97.601 EQUIPMENT DESIGNA TIONS.- DWH 1 EQUIPMEN T NUMBER EQUIPMEN T /DEN T/F /CA 77ON TYPE AC AIR COMPRESSOR ACC AIR COOLED CONDENSING UNIT AD ACCESS DOOR AF AFTER FILTER AHU AIR HANDLING UNIT BDD BACKDRAFT DAMPER CC COOLING COIL CH CHILLER CP CONDENSA 7E PUMP CT COOLING TOWER - OPEN OR CLOSED CUH CABINET UNIT HEATER CV CONSTANT VOLUME BOX DC DUST COLLECTOR DWH DOMESTIC WATER HEATER OWST DOMESTIC HOT WATER STORAGE TANK EF EXHAUST FAN ER ENERGY RECOVERY WHEEL FC FAN COIL FD FIRE DAMPER GV GRAVITY VENTILATOR H STEAM HUMIDIFIER HC HEA TING COIL HWCP DOMESTIC HOT WA TER CIRCULA TION PUMP H/X HEA T EXCHANGER IFB INTEGRAL FACE & BY -PASS COIL MUAU MAKE -UP AIR UNIT P PUMP PF PREF/L TER PHC PREHEA T COIL RH REHEA T COIL RF RETURN AIR FAN SA SOUND A TTENUA TOR SD SMOKE DAMPER SP SUMP PUMP UH UNIT HEA TER UV UNIT VENTILATOR VA VARIABLE VOLUME BOX VD VOLUME DAMPER ABBREWA TIONS- AFF ABOVE FINISHED FLOOR AD ACCESS DOOR BFP BACKFL0W PRE VENTER B TU BR/ FISH THERMAL UNIT 8 TUH BRITISH THERMAL UNIT PER HOUR Cl CAST IRON CLG CEILING DIWM DUCTILE IRON WATER MAIN DN DOWN DWG DRAWING EQUIP EQUIPMEN T ELEV ELEVA 77ON EWT ENTERING WA TER TEMPERA TORE F DEGREES FAHRENHEIT GAL GALLON GAL V GAL VANIZED GPD GALLONS PER DAY GPH GALLONS PER HOUR GPM GALLONS PER MINUTE HB HOSE BIBB HD HEAD HG INCHES OF MERCURY HP HORSEPOWER HZ CYCLES PER SECOND INV / lE INVERT / INVERT ELEVATION KW KILOWATTS L WT LEAVING WA TER TEMPERA TURF MBH THOUSAND BTUH NC NORMALL Y CLOSED NO NORMALLY OPEN NTS NOT TO SCALE PO PRESSURE DROP PH PHASE (0) PSIA POUNDS PER SQUARE INCH ABSOLUTE PS/G POUNDS PER SQUARE INCH GAUGE RPM REVOLUTIONS PER MINUTE SPEC SPECIFICA TION TD TEMPERA TURF DROP OR DIFFERENCE TDH TOTAL DEVELOPED HEAD TEMP TEMPERA TURF 7M THERMOS TA 77C MIXING VAL VE T & P TEMPERATURE & PRESSURE TYP TYPICAL UNO UNLESS N07ED OTHERWISE V VENTS, VOL IS VB VACUUM BREAKER VTR VENT THRU ROOF WC INCHES OF WATER COLUMN WHA WATER HAMMER ARRESTER SHEETMETAL LEGEND: (FOR DOUBLE LINE DUCT PLAN) SUPPL Y DUCT (IN SECTION) SUPPLY & O.A. INTAKE DUCT (END SECTION) EXHAUST, RETURN DUCT (IN SECTION) EXHAUST RETURN DUCT (END ELEVATION) EXHAUST DUCT DUCT DIMENSION IN INCHES (FIRST DIMENSION SIDE SHOWN) OUC T TURNED UP DUCT TURNED DOWN RISE IN DIRECTION OF FLOW DROP IN DIRECTION OF FLOW FLEXIBLE DUCT CONNECTION L.P. DUCT, BRANCH TAKE -OFF (KITH VOLUME DAMPER) ELBOWED WITH TURNING VANES OR SWEEP SHEETS MANUAL VOLUME DAMPER (RISER / HORIZONTAL DUCT) BACKDRAFT DAMPER (RISER / HORIZONTAL DUCT) SMOKE DAMPER FIRE DAMPER, 1 112 HR. (UNLESS NOTED OTHERWISE) COMBINA TION FIRE / SMOKE DAMPER ROUND FLEXIBLE DUCT SQUARE CEILING DIFFUSER SQUARE NECK SQUARE CEILING DIFFUSER ROUND NECK ROUND NECK / ROUND FACE DAMPER CEILING GRILLE, EXHAUST, RETURN OR TRANSFER SIDEWALL REGISTER OR GRILLE NTH EXTRACTOR AIR MONI TOR STA TION SHEETMETAL LEGEND: (FOR SINGLE LINE DUCT PLAN) SUPPL Y DIFFUSER RETURN / EXHAUST GRILLE OR REGISTER SIDEWALL REGISTER OR GRILLE LINEAR DIFFUSER OR REGISTER SUPPLY RISER: SQUARE / RECFANGLE SUPPLY RISER: ROUND / OVAL EXH. / RET. DUCT UP: SQUARE / RECTANGLE EXH. / RET. DUCT UP: ROUND / OVAL SOUND A TTENUA TOR RIGID SHEETMETAL TERM/NA TION OR CAP -OFF FLEXIBLE DUCT TO DIFFUSER DUCT TRANSITION BALANCING DAMPER BACKDRAFT DAMPER TRANSFER OPENING IN WALL ABOVE CEILING (L "x W"' / CFM) DUCT MOON TED REHEAT COIL DOOR GRILLE (L "x W") AIR VOLUME (CFM) UNDERCUT DOOR AIR VOLUME (CFM) ACCESS DOOR IN DUCTWORK ACCESS PANEL - CEILING ACCESS PANEL - WALL FIRE DAMPER - 1 112 HR (UNLESS NOTED OTHERWISE) COMBINATION FIRE & SMOKE DAMPER (SEE GENERAL NO TE j J.) DUCT UP TO EXHAUST FAN ON ROOF DIFFUSER DESIGNA TION 10 "0 -A -350 CFM, CUBIC FEET PER MINUTE SCHEDULE MARK NECK SIZE SPECIAL TERMINOL OG Y TERM D£SCR/P1TON 1 mi 24712' R —� BDD BDD SD FD FD SO AMS 0 (BDD 12x6 DG 1�- U_ 100 T AD AP AP pol UP ITEM PENETRA77NG STRUCTURAL COMPONENT ABOVE DOWN / TEM PENE IRA 77NG STRUCTURAL COMPONENT BELOW RISE l 7EM NO T PEN_FIRA 77NG STRUCTURAL COMPONEN T ABOVE DROP ITEM NOT PENETRA77NG STRUCTURAL COMPONENT BELOW GRAPHIC SYMBOLS FOR HVAC PIPING SYSTEMS: PIPE SPECIAL TIES: FP FIRE PROTECTION WATER SUPPLY P /P /N EXIS77NG LINE TO BE REMOVED sP AUTOMA TIC FIRE SPRINKLER — Sr— STORM DRAIN, DOWNSPOUT * AUTOMA TIC A/R VENT UPRIGHT SPRINKLER HEAD MEDIUM PRESSURE STEAM (16 TO 60 PS/G) MPS —0 -- PENDENT SPRINKLER HEAD S, W SYMBOLS - MANUAL A/R VENT Q LOW PRESSURE STEAM (1 TO 15 PS /G) BPS ALARM CHECK VALVE VENT �T THERMOS TA T PRESSURE GAUGE Q MEDIUM PRESSURE CONDENSA IF RETURN MPR AV — /W— OT G THERMOSTAT WITH WIREGUARD THERMOMETER (DIAL - BIMETALLIC) Q T LOW PRESSURE CONDENSATE RETURN LPR COLD WATER (CITY WATER) C OH HUMIDISTAT THERMOMETER (MECURY) — — — CONDENSA TE PUMP DISCHARGE PD _— MW — TEMPERED HOT WATER (105' F) RS ROOM SENSOR PIT PLUG SITE � SAFETY RELIEF VENT LINE sv A — VAC — VACUUM VAC PRESSURE TAP (PORTABLE GAUGE) VACUUM CLEANING HOT WATER SUPPLY HwS PIPE RISER UP --�� OF THE FLOOR PLAN ON WHICH THEY APPEAR, THERMAL WELL (PORTABLE GAUGE) T HOT WA TER RETURN HwR TEE CONNEC7ION UP & OVER T " FLEXIBLE PIPE CONNECTORS REFRIGERANT LIQUID RL DIELECTRIC FLANGE KIT IN -LINE PUMP F-- REFRIGERANT SUCTION RS CAPPED PIPE ANCHOR POINT �- CONDENSER SUPPLY Cs w ~ EXPANSION LOOP (D "xL) CONDENSER RETURN CR ALIGNMENT GUIDE CHILLED WA TER SUPPLY Cws FLOW METER (PI TOT TUBE) CHILLED WA ]ER RETURN CwR FLOW METER (ORIFICE) A/R VENT LINE AV FLOW METER (VENTURI) - MAKE- UP WATER MU FLOW SW TCH �� DRAIN LINE D PRESSURE SWTCH 9PS DIRECTION OF FLOW STRAINER �i DUAL TEMPERA TURE WA TER SUPPLY DTWS — STRAINER WITH BLOW DOWN DUAL TEMPERATURE WATER RETURN DTW — STEAM TRAP (FL OA T & THERMO) FIT STEAM STEAM TRAP (BUCKET) --�8 PIPELINE SYMBOLS; SIGHT GLASS (REFRIGERANT) -�-- SYMBOL DESCRIPTION A/R DRYER FILTER �- �— WATER HAMMER ARRESTER METER (WATER OR GAS) FLOW SWITCH PRESSURE SWITCH �-- BACKFL0W PRE VENTER AQUASTA T _'1HB __I WH HOSE BIBB - WALL HYDRANT VAL VES- -O OUTLET CONNECTION (A/R, GAS, ETC.) GA FE VALVE —� FLOW IN DIRECTION OF ARROW — PITCH DOWN IN DIRECTION OF ARROW GLOBE VAL VE BUTTERFLY VALVE BALL VAL VE I DRAINAGE SYMBOLS.' SWING CHECK VALVE N SYMBOL DESCRIP7ON ABBREVIATION NON —SLAM CHECK VALVE NS � , �I ® EQ FLOOR DRAIN FD ® EQ ROOF DRAIN RD FLOW CONTROL VAL VE IOI ® QFQ OVERFLOW DRAIN OFD GAS COCK (V —o -CQ FLOOR CLEANOUT' (OR TO GRADE) FCO IRON BODY CLEANOUT PLUG IBCO PRESSURE REDUCING VALVE I TWO -WAY TC VALVE � WALL CLEANOUT WCO THREE —WAY FC VALVE (MIXING) THREE —WAY FC VALVE (DIVERTING) FIRE PRO TEC TION S YMBOL S.- SYMBOL DESCRIPTION DESCRIPTION ABBREWATI0N FP FIRE PROTECTION WATER SUPPLY EXIS77NG LINE TO BE REMOVED sP AUTOMA TIC FIRE SPRINKLER — Sr— STORM DRAIN, DOWNSPOUT * ST, DS UPRIGHT SPRINKLER HEAD STORM DRAIN UNDERGROUND ST —0 -- PENDENT SPRINKLER HEAD S, W SYMBOLS - WA TER FLOW INDICA TOR S, W — — SUB -SOIL DRAIN, FOOTING DRAIN SSD ALARM CHECK VALVE VENT �T THERMOS TA T FIRE DEPARTMENT CONNEC 77ON A O N NIGHT THERMOS FA T AV — /W— OT G THERMOSTAT WITH WIREGUARD — 1D — INDIRECT DRAIN O DAMPER MOTOR OPERATOR COLD WATER (CITY WATER) C OH HUMIDISTAT PIPE Fl T TINGS- — — — HOT WATER RETURN (120' F) HWR _— MW — TEMPERED HOT WATER (105' F) RS ROOM SENSOR ECCENTRIC REDUCER / INCREASER -{--�- — A — COMPRESSED AIR A — VAC — VACUUM VAC CONCENTRIC REDUCER / INCREASER VACUUM CLEANING VC DIFFERENTIAL PRESSURE TRANSMITTER PIPE RISER UP --�� OF THE FLOOR PLAN ON WHICH THEY APPEAR, PIPE RISER DOWN UNLESS NOTED OTHERWISE. TEE CONNEC7ION UP & OVER T " FEE CONNECTION DOWN & OVER DIELECTRIC FLANGE KIT UNION F-- CAPPED PIPE PLUMBING PIPELINE IDENTIFICATION SYMBOLS: SYMBOL DESCRIPTION ABBREWATI0N EXISTING LINE TO REMAIN * EXIS77NG LINE TO BE REMOVED — Sr— STORM DRAIN, DOWNSPOUT * ST, DS -r d- ST = STORM DRAIN UNDERGROUND ST SOIL OR WASTE * S, W -�� SOIL OR WASTE UNDERGROUND S, W — — SUB -SOIL DRAIN, FOOTING DRAIN SSD - - -V - -- VENT V — AW — ACID WASTE A —AV— ACID VENT AV — /W— INDIRECT WASTE I — 1D — INDIRECT DRAIN ID — — — COLD WATER (CITY WATER) C — — — — HOT WATER (120' F) H — — — HOT WATER RETURN (120' F) HWR _— MW — TEMPERED HOT WATER (105' F) THW —G— GAS G — A — COMPRESSED AIR A — VAC — VACUUM VAC — vC — VACUUM CLEANING VC * PIPELINES SHOWN ARE IN THE CEILING SPACE OF THE FLOOR PLAN ON WHICH THEY APPEAR, UNLESS NOTED OTHERWISE. NOTE DESIGNATIONS., PLAN NOTE: SPECIFIC INFORMA ]ION AS INDICATED ON A DRAWING LEADER LINE OF PLAN NOTE REFERENCED DIRECTED TO ITEM OF PLAN NOTE REFERENCED. CIRCLE WIN NUMBER INDICATES A PLAN NOTE REFERENCED WI TH THE NUMBER INDICA 77NG THE ITEM NUMBER OF THE PLAN NOTE REFERENCED, GENERAL PLAN NO TE.. GENERAL /NFORMA 77ON AS I T PERTAINS ONLY TO THE DRAWING I T IS ON. GENERAL NOTE: GENERAL INFORMATION PERTAINS TO ALL THE DRAWINGS OF THE DISCIPLINE IT IS ON WATER HAMMER ARRESTER DESIGNA TIONS-' ,q ELLIPSE WI TH LETTER INDICATES WATER HAMMER ARRESTER LETTER INDICATES WATER HAMMER ARRESTER SIZE, AS PER POI STANDARD, PDI -WH 201 (PLUMBING AND DRAINAGE /NS77TU7E) FLOOR DRAIN DESIGNATIONS 2 FD A, DRA WING SYMBOLS: IDENTIFICATION OF DRAIN TYPE, REFER TO DIVISION 15 OF SPECIFICA TION FLOOR DRAIN DRAIN SIZE EQUIPMENT IDENTIFICATION CODE EQUIPMENT NUMBER DETAIL NUMBER SHEET NUMBER SEC TION DIRECTION SECTION NUMBER SHEET NUMBER ME GENERAL NO TES.- CONNECT NEW TO EXISTING 1. ALL SYMBOLS AND ABBREVIATIONS PRESENTED ON THIS SHEET MAY OR MAY NOT BE USED ON THE FOLLOWING DRAWINGS. 2. THIS SYMBOL ON THE MECHANICAL AND ELECTRICAL PLANS INDICA T57S ELECTRICAL EQUIPMENT SWITCHBOARDS / PANELBOARDS / MOTOR CONTROL CENTERS. THE CONTRACTOR SHALL MAINTAIN A MINIMUM OF 3' -0" FRONT WORKING SPACE AND, IN AODI TTON, AN EXCLUS/VEL Y DEDICA TED SPACE EXTENDING FROM FLOOR TO STRUCTURAL CEILING WITH A WIDTH AND DEPTH OF THAT EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 110 -11, ARTICLE 384 -4 AND 384 -51 AND FIGURES 110 -8 THROUGH 110 -11 AND FIGURE 384 -1, 384 -2. NO PIPING, DUCTWORK OR EQUIPMENT FOREIGN TO THE ELECTRICAL EQUIPMENT OR ARCHITECTURAL APPURTENANCES, SHALL BE PERMITTED TO BE INSTALLED IN, ENTER OR PASS THROUGH, SUCH SPACES OR ROOMS. 3. REFER TO SPECIFICA TION SECTIONS 15910 AND 16720 OR 16721 FOR SMOKE DETECTOR /NSTALLA 170N REQUIREMENTS •••.."""„«. , °G S T I' No, ° 13815WY STATE OF 4,4/ oNk . ;f MOORE ENGINEERS A PROFESSIONAL CORPORATION 9245 N. Meridian Street, Suite 105 Indianapolis, Indiana 46260 -1812 317.848.5045 PH 317.848.2765 FX St. Vincent Carmel Hospital 13500 A llleridian Street P.O. Box 1903 0arine4 Indiana 46032 CARMEL MEDICAL BUILDING No. 1 SUITE 315/355 Carmel, Indiana i