HomeMy WebLinkAbout1218.97.9TIh7i�� ALL WORK FOR T41S PROJECT SHALL CONFORM TO THE REQUIREMENTS OF ALL APPLICABLE CODES AND AUTHORITIES HAVING JURISDICTION. THE CONTRACTORS SHALL: REVIEW THE CONTRACT DOCUMENTS OF ALL TRADES TO FULLY INFORM THEMSELVES OF THE SCOPE OF THE WORK REQUIRED FOR THIS PROJECT ARRANGE TO VISIT THE PROJECT S17F BEFORE SUBMITTING THEIR BID ON THE PROJECT. THE CONTRACTORS ARE RESPONSIBLE FOR PLACING THEIR OWN INTERPRETATION ON EXISTING COND177ONS AND LIMITATIONS. PROVIDE AND INSTALL ACCESS PANELS AND DOORS AS REQUIRED TO ALLOW PROPER ACCESS TO MECHANICAL WORK. REMOVE ALL RUBBISH AND WASTE FROM THE PROJECT S1 TE AS IT IS GENERA TED (AT LEAST DAILY). PROVIDE ALL CUTTING AND PATCHING NECESSARY FOR THE INSTALLATION OF MECHANICAL WORK. CUTTING OF STRUCTURAL MEMBERS SHALL NOT PROCEED WI THOUT THE WRI TTEN AUTHORIZA T/ON OF THE STRUCTURAL ENGINEER. OBTAIN AND PAY FOR (AS A PART OF THE QUOTED PRICE FOR THE WORK) ALL NECESSARY PERMITS, LICENSES AND FEES. GUARANTEE ALL NEW MA7ERIALS, EQUIPMENT AND INSTALLATION FROM ALL DEFECTS IN WORKMANSHIP AND /OR MATERIALS FOR A PERIOD OF ONE YEAR, BEGINNING W17H THE DATE OF PROJECT SUBS TAN77AL COMPLETION. EQUIPMENT MANUFACTURERS WARRANTIES SHALL BE EXTENDED AS NECESSARY TO FULFILL THIS REQUIREMENT. SUBMIT SIX COPIES OF SHOP DRAWINGS FOR ENGINEERS REVIEW. SHOP DRAWINGS SHALL BE SUBMITTED ON EQUIPMENT, RTU, ELECTRIC HEATERS, HUMIDIFIERS, GRILLES, REGISTERS, DIFFUSERS, VALVES, DUCTWORK, TEMPERATURE CONTROLS, ETC.. COORDINA IF THE INSTALLATION OF MECHANICAL WORK WT TH THE WORK OF ALL OTHER TRADES 774E DRAWINGS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO INDICATE ALL OFFSETS AND FITTINGS THAT MAY BE REQUIRED TO COMPLETE THE PROPER INSTALLATION OF ALL SYSTEMS SHOWN. IT 1S 7HE CONTRACTORS RESPONSIBLLI TY TO PROVIDE FINAL COORD/NA TION OF THE /NSTALLA 77ON DETAILS OF THEIR SYSTEMS. BASIC MATERIALS AND METHODS MARK ALL NEW PIPING SYSTEMS WITH SETMARK" IDEN77F /ES (SETON CORPORATION) PIPING SHALL BE MARKED ON EACH SIDE OF EACH WALL PENETRATION AND AT 20 FOOT INTERVALS WITHIN A ROOM. TAG ALL NEW VALVES WITH A BRASS TAG ATTACHED TO THE VALVE W/TH A NYLON DRAW BAND. VA VE /DENT/FICA RON SYSTEM SHALL BE AS APPROVED BY THE OWNER BEFORE INSTALLATION. PROVIDE A REDUCED SCALE PLAN TO THE OWNER /NDICA77NG THE LOCATION OF EACH VALVE, SIZE, SERVICE, ETC. (INCLUDE EXISTING VALVES WHERE APPROPRIATE TO THE NEW SYSTEMS). NUMBER ALL VALVES SEQUENTIALLY AND LIST THE APPLICABLE SERVICE. INSULA /TON REFRIGERANT SUCTION LINES ARE TO BE COVERED WITH 112" THICK ARMAFLEX. ALL CONCEALED INTERIOR DUCTS -ARE TO BE INSULATED WITH 2" THICK FIBERGLAS WITH FRK FACING, 314 POUND PER CUBIC FOOT DENSITY. WELD IMPALING PINS TO BOTTOM OF DUCTS SO SUPPORT IS AT 12" CENTERS IN ALL DIRECTIONS SECURE INSULATION TO 774ESE PINS WI TH APPROPRIA TE FASTENERS. Pl lNG REFRIGERANT PIPING: COPPER TUBING — ASTM B 280, TYPE ACR, HARD —DRAWN STRAIGHT LENGTHS, AND SOFT— ANNEALED COILS, SEAMLESS COPPER TUBING. TUBING SHALL BE FACTORY CLEANED, READY FOR INSTALLATION, AND HAVE ENDS CAPPED TO PR07ECT CLEANLINESS OF PIPE INTERIORS PRIOR TO SHIPPING. FI T RNGS: WROUGHT— COPPER F/TT/NGS — ANSI B16.22, STREAMLINED PA TTERN. JOINING MA TER/ALS BRAZING FILLER METALS — AWS A5.8, CLASSIFICATION BAG -1 (SILVER) REFRIGERANT.• REFRIGERANT NO. 22, IN ACCORDANCE WITH ASHRAE STANDARD 34. CHARGE SYSTEM USING THE FOLLOWING PROCEEDURE. INSTALL CORE IN F/L TER DRYER AFTER LEAK TEST, BUT BEFORE EVACUA RON. EVACUATE REFRIGERANT SYSTEM WITH VACUUM PUMP; lIN77L TEMPERATURE OF 35' F. IS INDICATED ON VACUUM DEN YDRARON INDICATOR. DURING EVACUATION, APPLY HEAT TO POCKETS, ELBOWS, AND LOW SPOTS IN PIPING. MAINTAIN VACUUM ON SYSTEM FOR MINIMUM OF 5 HOURS AFTER CLOSING VALVE BETWEEN VACUUM PUMP AND SYSTEM. BREAK VACUUM WITH REFRIGERANT GAS, ALLOW PRESSURE TO BUILD UP TO 2 PSI, COMPLETE CHARGING OF SYSTEM, USING NEW FILTER DRYER CORE IN CHARGING LINE. PROVIDE FULL OPERA 77NG CHARGE. PROVIDE AND INSTALL ADJUSTABLE COPPER PLA7ED CLEWS HANGERS FOR ALL HORIZONTAL RUNS OF COPPER PIPING. SUPPORT EACH PIPE ON MAXIMUM 8'— 0" CENTERS WITH A MINIMUM 3/8" HANGER ROD. MULTIPLE PIPING RUNS MAY BE ACCOMMODA TED WI TH APPROPRIA TE TRAPEZE HANGERS A T THE CONTRACTORS DISCRETION. ALL PIPING SHALL BE CONCEALED ABOVE CEILINGS, IN WALLS, IN CHASES, ETC., UNLESS SPECIFICALLY NOTED TO THE CONTRARY ON THE DRAWINGS. WHERE PIPING PASSES THROUGH FIRE AND /OR SMOKE RATED PAR 77TIONS (REFER TO ARCHITECTURAL DRAWINGS), PROVIDE SLEEVES AND APPROPR /A TEL Y RA TED SEALING MATERIALS AS REQUIRED TO MAINTAIN FIRE RATED ENCLOSURE. SHEET METAL ALL NEW DUCTWORK SHALL BE GALVANIZED SHEET STEEL CONFORMING TO ANSI /ASTM A 527, LOCKFORM/NG QUALITY AND ANSI /ASTM A 525, G90 ZINC COATING. DUCT SEALANT.- NONHARDEN/NG, NONMIGRA TING MASTIC OR LIQUID ELASTIC SEALANT (TYPE APPLICABLE FOR FABRICA TION //NSTALLA T70N DETAIL) AS COMPOUNDED AND RECOMMENDED BY MANUFACTURER SPECIFICALLY FOR SEALING JOINTS AND SEAMS IN DUCTWORK. DUCT CEMENT- NONHARDEN/NG MIGRATING MASTIC OR LIQUID NEOPRENE BASED CEMENT (TYPE APPLICABLE FOR FABRICA 770NIINSTALLA 77ON DETAIL) AS COMPOUNDED AND RECOMMENDED BY MANUFACTURER SPECIFICALLY FOR CEMEN77NG FITTING COMPONENTS, OR LONGITUDINAL SEAMS IN DUCTWORK. FABRICATE DUCT TRANS/BONS TO MA TCH ADJOINING EQUIPMENT AND TO COMPLY WITH DUCT REQUIREMENTS AS APPLICABLE TO FITTINGS. LIMIT ANGULAR TAPERS TO 30 DEGREES FOR EXPANDING TAPERS. INSTALL A BALANCE DAMPER AT EACH DUCT BRANCH TAKE —OFF ON EACH DUCT SYSTEM. PROVIDE LOCKING QUADRANT, EXTENDED AS NECESSARY FOR DUCT INSULATION. CONSTRUCT AND SUPPORT ALL NEW DUCTWORK IN ACCORDANCE WITH SMACNA STANDARDS FOR LOW PRESSURE DUCTWORK. INSULA TED FLEXIBLE DUCT SHALL BE USED AT THE FINAL CONNECTION TO DIFFUSERS FLEXIBLE DUCT SHALL BE LIMITED TO A MAXIMUM LENGTH OF 5' -0" AND A TOTAL OF 90 DEGREES IN TURNS (AT EACH LOCATION). —.0 TEMPERATURE CONTROLS RTU -1 DURING OCCUPIED CYCLE, THE SUPPLY AIR FAN SHALL BE ON AND THE MINIMUM OUTSIDE AIR DAMPER SHALL BE OPEN. STAGES OF COOLING SHALL BE ENERGIZED AND HOT GAS BYPASS VALVE SHALL MODULA TE TO MAINTAIN 55' DISCHARGE AIR TEMPERA TURF. DURING UNOCCUPIED CYCLE, THE SUPPLY AIR FAN SHALL BE OFF AND THE MINIMUM OUTSIDE AIR DAMPER SHALL BE CLOSED. IF THE TEMPERATURE AT THE NIGHT SETBACK THERMOSTAT DROPS TO NIGHT SETBACK TEMPERATURE OF 60; THE SUPPLY AIR FAN SHALL START, ANO ENABLE THE DUCT COILS TO MAINTAIN NIGHT SETBACK TEMPERATURE. FAN COIL UNITS FAN COIL UNITS SHALL BE CONTROLLED BY EXISI RIG, RELOCATED WALL MOUNTED THERMOSTATS. WHERE AN OUTSIDE AIR DUCT ANO MOTORIZED DAMPER ARE INDICATED, THE DAMPER SHALL OPEN WHEN THE FAN OPERA TES EXHAUST FANS EXHAUST FAN EF -1 SHALL OPERA IF DURING OCCUPIED CYCLE OF RTU -1. EXHAUST FAN EF -2 SHALL OPERATE WHEN THE TOILET ROOM LIGHT IS ON. CONTROL AND POWER WIRING FOR THIS FAN SHALL BE BY THE E. C. DUCT COILS ELECTRIC DUCT COILS SHALL BE ENERGIZED BY FIELD MOUNTED WALL THERMOSTATS PROVIDED BY THE MANUFACTURER. HUMIDIFIERS ELECTRONIC HUMIDIFIERS SHALL BE ENERGIZED BY FIELD MOUNTEO WALL HUM /D/STATS PROVIDED BY THE MANUFACTURER. SY57EM BALANCE AIR BALANCE SHALL BE COMPLE7ED BY A NEEB CERTIFIED CONTRACTOR. PROVIDE A TYPED WRIT7EN REPORT /NDICA77NG THE COMPLETE READ —OUT OF EACH AIR INLET AND OUTLET, AND FAN PERFORMANCE. SUBMIT FINAL REPORT TO 774E ENGINEER FOR REVIEW. P/ TCH DOWN TOWARD D° A'"' CLEAN OUT-1 DRAIN LINE SHALL BE AT LEAST 774E SAME SIZE AS THE NIPPLE ON THE DRAIN PAN ---\ CLEAN OUT I " FL OOR TLxj DRAIN �—DRAIN PAN OF A v AHU OR FCU 2" MIN. FOR AHU S, — — I" MIN. FOR FCU S Q, UNI T TYPE A B DRAW THROUGH P + I" P P =STA 77C PRESSURE AT DRAIN PAN CONDENSATE DRAIN TRAP DETAI NO SCALE FLEXIBLE S7FAM SUPPL Y HOSE AND COND. RETURN HOSE PROVIDED BY HUMIDIFIER MANUFACTURER, INSTALLED " T"IBUTION 'E HUMI1 NO SCALE GRAIN LINE FROM HUMIDIFIER ER PIPING DETAIL PACKAGED ROOFTOP UNIT SCHEDULE EXAMPLE SUPPLY FAN DATA COOLING COIL DATA CONDENSER ELECTRICAL DATA MARK MANUFACTURER CFM ESP FAN MOTOR MIN_ TOTAL SENS_ EAT LAT AMB. NO. OF MODEL NO. RPM H.P_ O.A_ MBH MBH WB /DB WB /DB TEMP_ FANS VOLTS PH. FLA MFS R TU -1 AAON RK -13 -3 3900 3.0 1919 5 630 151.8 123 4 830164.9 539151.5 95 2 460 3 33 40 REMARKS: 1O UNIT SHALL BE DOUBLE WALL CONSTRUCTION, HAVE DUAL REFRIGERATION CIRCUITS, HAVE HOT GAS BYPASS ON ONE CIRCUIT, HA VE LOW AMBIENT CONTROLS TO OPERA TE TO 0 ; HA VE FUSED DISCONNECT, HA VE MO TOR /ZED OU TS /DE A/R DAMPER, HA VE 309 PREF /L TERS, AND HA VE 907 FINAL F/L TERS. PROVIDE 30" TALL ROOF CURB, EQUIPPED WI TH FINAL FILTER HOLDING FRAME TO CONTAIN THE FINAL F/L TER. J REMARKS DUCT COIL SCHEDULE MARK EXAMPLE MANUFACTURER MODEL NO, AIR SIDE DATA CAP' K.W. STAGES ELECTRICAL SIZE REMARKS CFM EAT LAT VOLTS PHASE WIDTH HEIGHT DC -1 /NDEECO TYPE QUA 500 55 85 5.0 2 480 3 12 10 1 DC -2 /NDEECO TYPE QUA 500 55 85 5.0 2 480 3 12 10 1 DC -3 /NOEECO TYPE QUA 1645 55 85 175 4 480 3 24 12 DC -4 /NDEECO TYPE QUA 1255 55 80 10.0 2 480 3 18 12 DC -5 /NDEECO TYPE QUA 210 55 80 1.7 1 480 3 8 8 DC -6 /NDEECO TYPE QUA 135 55 95 1.8 1 480 3 8 8 DC-7 /NDEECO TYPE QUA 350 55 95 5.0 2 1 480 3 10 8 REMARKS: O1 PROVIDE WITH CONTROL OPTION "G" WALL MOUNTED ROOM THERMOSTAT, AND MERCURY CONTACTORS. FAN SCHEDULE MARK EXAMPLE MANUFACTURER MODEL NO, LOCATION SERVICE CFM T.S.P. RPM DRIVE TYPE MOTOR DATA REMARKS HP /WATTS RPM VOLTS PHASE EF -1 GREENHECK GB -80 ROOF EXHAUST 375 0.5 1230 BEL T 114 HP 1230 115 1 2 EF -2 GREENHECK SP -218 CE /LING EXHAUST 150 0.25 1400 DIRECT 113 WATTS 1750 115 1 O REMARKS Ol PROVIDE WITH CURB MOUNTED ROOF VENT MODEL GRS -10. 2O PROVIDE WITH ROOF CURB, BACKDRAFT DAMPER, AND DISCONNECT SWITCH. HUMIDIFIER SCHEDULE MARK EXAMPLE MANUFACTURER MODEL NO_ CFM DUCT SIZE CAPACITY LBS /HR STEAM PSIG STEAM DISTRIBUTOR ELECTRICAL REMARKS K. W. VOLTAGE PHASE H -1 NORTEC NHB -010 1000 14 x 12 11 0 ASD -12 38 480 1 1 H -2 NOR7EC NHB -005 520 12 x 10' 5 0 ASD -12 1.9 120 1 Ol REMARKS: Ol PROVIDE WITH WALL MOUNTED ON /OFF HUMIISTAT, DUCT MOUNTED AIR FLOW SWITCH, AND DUCT MOUNTED HIGH LIMIT HUMIDISTAT. �O SST 4 �\ 'F.G No. ° 13815 s, STATE an1►mimn , / /�'�� A PROFESSIONAL CORPORATION 9245 N. Meridian Street, Suite 105 Indianapolis, Indiana 46260.1812 317.848.5045 PH 317.848.2765 FX St. ViBent Carmel Hospital 13600 N. Maridlan SYrset P.O. Boz 1903 Carmel Ind/am 48082 MO TOR cc DOME CARMEL INTEGRAL WOOD NAILER = MEDICAL ROUTE ROOF MEMBRANE UP TO BIRDSCREEN BUILDING UNDER COUNTER FLASHING AND SECURE TO W000 NAILER AT No. 1 TOP OF CURB SET IN SEALANT 20' 30' ROOF INSULA 77ON GYP. BOARD SUITE 315/355 Carmel, Indiana 4 "x4 X3/16" ANGLE ALL AROUND 20' 30' MECHANICAL NOTE, BACKDRAFT DAMPER J SPECIFICATIONS, THE / TFD ANGLES OF SCHEDULES & DETAILS EXPANSION NSION & CONTRACTION ARE THE RECOMMENDED MAXIMUMS CONTROL PANEL SCALE 1/8" - 1' -0" CLIENT NO. ROOF OPENING DUCT TRANSITION TO REHEAT COIL DATE 9 -29 -97 COMMISSION 87055 3 NO SCALE ROOF MOUNTED DOME EXHAUST 4 NO SCALE COORD DWS DRAWN DWS \TR M3 APPROVED GLP