Loading...
HomeMy WebLinkAbout1125.97.1PARAPET DETAL SCALE: 1 1/2' -1' -0' REMOVE AND EXISTING LIGHTNING PROTECTION SYSTEM REMOVE, REPAINT, & REINSTALL EXISTING METAL COPING NEW 2 PLY SBS ROOF MEMBRANE NEW CANT STRIP NEW RECOVERY BOARD NEW TAPERED INSULATION EXISTING CONSTRUCTION TO REMAIN REMOVE EXISTING SHINGLES AS REQUIRED NEW SHINGLES TO MATCH EXISTING AS REQUIRED NEW METAL COUNTER FLASHING W/ DRIP EDGE NEW 2 PLY SBS ROOF MEMBRANE NEW CANT STRIP NEW RECOVERY BOARD NEW TAPERED INSULATION: DEPTH VARIES, SEE PLAN EXISTING CONSTRUCTION TO REMAIN DETAE. 0 EXISTING SF04GLED ROOF 9 SCALE- 11/2' -1' -0' I SHINGLE OR SBS ROOF: SEE PLAN NEW METAL'CbUNTER FLASHING W/ DRIP EDGE CMOVE EXISTING GUTTER EXISTING CONSTRUCTION TO REMAIN REMOVE EXISTING PLYWOOD SIDING NEW RECOVERY BOARD 2 PLY SBS ROOF MEMBRANE NEW CANT STRIP NEW RECOVERY BOARD =W TAPERED INSULATION =PTH VARIES: SEE PLAN EXISTING CONSTRUCTION - - TO REMAIN DETAIL • EXISTING SHINGLED ROOF SCALE 11/2' -1' -0' 1211 — 11/811 REMOVE AND REPLACE EXISTING BEEHIVE GRATE. PROVIDE NEW IF DAMAGED OR MISSING INSTALL NEW ROOF MEMBRANE UNDER EXIST. CLAMPING RING NEW 2 PLY SBS ROOF MEMBRANE OVER NEW RECOVERY BOARD HELD BACK 4' -611 FROM DRAIN (TYP.) NEW TAPERED INSULATION DETAL • ROOF DRAM SCALE: 1 1/2' -1' -0' EXISTING SHINGLED ROOF TO REMAIN 7� 4 A -1 RD TYP. RD NEW TAPERED INSULATION 0 1/8' — PER FOOT OVER EXISTING BUR, 11r RECOVER BOARD, AND NEW 2 PLY SBS MODIFIED BITUMEN ROOF TYPICAL.. PROVIDE TAPERED INSLXATION CRICKETS BETWEEN EXISTING DRAINS 0 1/16' PER FOOT TYPICAL EXISTING CONSTRUCTION TO REMAIN EXISTING ROOF DRAIN TO REMAIN OPEN TO COURTYARD BELOW -RD NEW SBS MODIFIED ROOF OVER EXISTING SHINGLED ROOF 7� EXISTING SHNGLED ROOF TO REMAIN , RD • EXISTING SBS MODIFIED ROOF-TO REMAIN EXISTING JOINT BETWEEN FLAT BUR AND TAPERED SBS MODIFIED ROOF r.' , RD GENERAL NOTES: 1. CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL CONDITIONS. 2. REMOVE AND REPLACE EXISTING LIGHTNING PROTECTION SYSTEM AS REQUIRED. 3. REMOVE AND REPLACE EXISTING GAS PIPING AS REQUIRED. 4. ANY DETAIL NOT COVERED BY THESE DOCUMENTS SHALL BE CONSTRUCTED PER MANUFACTURER'S REQUIREMENT, SMCNA MANUAL TYPICAL DETAILS, AND TYPICAL INDUSTRY PRACTICE. 5. REPLACE ANY EXISTING MISSING OR DAMAGED ROOF DRAIN BEHIVES. 6. DETAIL EXISTING OVERFLOW SCUPPERS PER SMCNA DETAILS. 7. SBS ROOFING COLOR TO MATCH SHINGLES. BROADCAST ADDITIONAL GRANUALS AT )OINTS IN VISIBLE LOCATIONS. 8. INSPECT EXISTING FRONT CANOPY FOR LEAKS AND REPORT TO ARCHITECT. 9. INSTALL NEW FLASHING AND CANT STRIPS TYPICAL. 10. REUSE EXISTING COUNTERFLASHINGS U.N.O. 11. FLASH EXISTING ROOF PENETRATIONS PER MANUFACTURER'S STANDARD DETAILS. 12. ALL ROOF DRAINS SHOWN ARE EXISTING, SEE DETAIL #4 0 1 1 1 6 i f 1 i t 1 1 T i EXISTING JOINT BETWEEN FLAT BUR AND TAPERED SBS MODIFIED ROOF EXISTING SBS MODIFIED ROOF TO REMAIN DS � t t t ' t t NEW SHINGLED ROOF OVER EXISTING .,l t t 1 t 1 _ � t t 1 � a t ` t DS ' 444 w\ NEW COLUMN FOOTING 1 SEE DETAIL 3/A -2 - .J 7tW*W 1/3 OF SPAN 2/3 OF SPAN OVERBUI D EXISTING ROOF STRUCTURE. T (TYP.) 1/8' PER 12' \ o 4 b A -2 J 1 A -2 OVERBUILD EXISTING ROOF STRUCTURE. 1/8' PER 12' NEW SBS MODIFIED ROOF OVER EXISTING SHNGLED ROOF NEW GUTTER NEW SBS MODFED ROOF OVER EXISTING BUR NEW 2r x 7r NOM. SKYLKGiT TYPICAL: SEE DETAIL. 41A -2 NEW SBS MODIFIED ROOF OVER EXISTING ROOF PLAN cru c. �In• _ �r ro r � o� V oG V . Lt—� V oG V U. ow IW6 c) 03: < .� �W o f Z all _j ao ui j < �Z u Ile- oc � h CL fF�T