HomeMy WebLinkAbout1144.97.7u/s of celIN ,foists
�n X
top of floor OwmKhN
Qu/s of COON
r
i
to of floor 00a
N- top of foundation
4i
;
v ,top � of floor slab
top of foo"
bottom of footN
N
TH18 PART OF THE STAIR SECTION SNOWS
THE LOCATION FOR RAFTER BEARING ALL
AROUND THE LOOM LEVEL PERIMETER OF
STRUCTURE, AND THIS CONDITION WILL APPLY
UNLESS NOTED SPECIFICALLY, ALSO NOTE
THE ADJUSTMENT OF WALL HEIGHTS IN
GARAGE AND AREAS OF COMMON WALLS
OF GARAGE/ HOUSE FOR TALLER JOISTS OVER
GARAGE AREA IF NOTED ON PLAN AND
ENGINEERED FLOOR LAYOUT.
STAIR SECTION
SCALE: 1 /4" - 1' -0"
L- XIC.ICI T" rITGH
CLG. INSULATION R -38
1/1" DRYWALL
R -145
INSIDE AIR FILM
R -b8
1X4 STUD WALL W/ BATT
R -13
1111 HICsN R INSUL SHEATHING
R-4.6
OUTSIDE AIR FILM
R -.11
314" AIR SPACE
R -lA
4" BRICK VENEER
R -,8
TOTAL R -VALUE
CLG. INSULATION R -38
I/1" DRYWALL
R -,45
INSIDE AIR FILM
R -,68
1X4 STUD WALL W/ BATT
R -13
V1" NIGH R INSUL SWEATNING
R-4,6
OUTSIDE AIR FILM
R -,I1
3/4" WOOD SIDINfi
R -1.05
TOTAL R -VALUE
QW.0ALC` Ug s I -V
QC COPYRICsNt 1991 RAY ROEHLINCs HOMES
NOTE:
VENTILATE ROOF TO 1 /300TH OF INSULATED CEILING AREA.
- FIBRE MESH REINFORCEMENT
- COMPACTED GRANULAR FILL
TYPICAL SECTION
SCALE; 114" = I' -0"
MANTLE AS SPECIFIED
1 -2X1'1 HEADER 0 OPENING
HEARTH EXTENSION
DOUBLE JOIST UNDER FIREPLACE
TYPICAL TRUSS ROOF
- M225 ASPHALT SHINGLES
- 3/8" ROOFING PLYWOOD C/W
'W' CLIPS
- 2x8 BLOCKING AT WEAK
- PRE - ENGINEERED TRUSSES 9 24" oz,
- 2x4 TRUSS BRACING
- R40 BATT INSULATION
6 MIL POLY VB.
- 5/8" CEILING BOARD
TAPED t SANDED
6" GUTTER BOARD
SOFFITT MAT'L AS SPECIFIED
PROVIDE VENTING 6 48" oz,
- TYPICAL
IX2 ON IXS FRIEZE BOARD
HORIZONTAL SIDING
TYPICAL BRICK EXTERIOR WALL
- FACE BRICK
- l GAUGE CORRUGATED
GALVANIZED METAL BRICK TIES
- 1/2" AIR SPACE
- 1/16" PLYWOOD SHEATHING
- 2x4 STNS 0 16' ox,
- R13 BATT INSULATION
- b MIL POLY VB.
- 1/2" DRYWALL
TAPED AND SANDED
TYPICAL SILL ASSEMBLY
- 1/2" DIA. ANCHOR BOLT 6 12" o,c.
- 2xb PRESSURE TREATED SILL PLATE
- 1/4" SILL GASKET
TYPICAL BASEMENT WALL
- 1/1' DRYWALL
- 1" x 4' STUDS 9 24" oz,
- BATT INSULATION
- 6 mH POLY VAPOR BARRIER
- 8" CONCRETE FOUNDATION WAL.
- ASPHALTIC DAMPPROOFING
16" WIDE x 8" DEEP
CONCRETE FOOTING c/w
2 - RUNS 15M REBAR
CHIMNEY CAP AS REQ'D
APPROVED FLUE PIPE
AS REQ'D
2X FRAMING AS RW`D
OPERABLE METAL DAMPER
METAL FIREPLACE BOX
.. 40 = . ,
LL
LU
U
111
_a
cA
Ul
w
LLI
z
� d
N
Q� W
�[ 0
U n-
S,
!11
U
U �
X11 w
U
C-4 O
W
m Q
� a
W �
z�
w
o�
0
DATE Oi
DRAWN BY: Jj�
SCALE 114
REVISIONS=
SHEET