HomeMy WebLinkAbout1254.97.13SPLICE BOLT TABLE ROOF SLOPE OVER 12 • 1 1 � REACTION DEAD COLL LIVE SNOW WIND WIND WIND WIND WIND SETS SPLICE N0. SIZE • 114 26 - 3'2 MEMBERS LOAD LOAD LOAD LOAD LEFT1 LEFT2 RIGHTI RIGHT2 LONG. LOAD A 8 x 0-2'2" VENT LEFT COL HOR 0.4 0.5 2.2 2.2 -3.1 0.0 0.0 0.0 0.4 -1.3 B 8 a fl x 0 -2 2" LEFT COL VER 1.8 2.0 8.0 8.0 -3.8 0.0 0.0 0.0 -2.7 -1.2 RIGT COL HOR -0.4 -0.5 -2.2 -2.2 -1.3 1 0.0 0.0 1 0.0 1 -04 - 1 .3 RIGT COL VER 1.8 2.0 8.0 8.0 -1.6 1 0.0 0.0-1 0.0 1 -2.7 1.2 REACTION UNBAL MEMBERS LEFT LEFT COL. HOR 1.4 4.8 K LEFT COL. VER 2.3 ~- RIGT COL. HOR -1.4 4.3 K RIGT COL. VER 7.7 THE REACTIONS ARE STATED IN KIPS (1 KIP = 1000 POUNDS). THE REACTIONS SHOWN MUST ACT ON THE FRAME IN THE DIRECTION SHOWN • TO MAINTAIN STABILITY. THE REACTION ON THE ANCHOR BOLT OR FOUNDATION REACTIONS AT WALL X- BRACING WILL BE IN THE OPPOSITE DIRECTION TO THAT INDICATED BY THE TABLE. STANDING SEAM RIDGE GAP ± + +t 1+ SECTION 0 PANEL END 12 ONE MIN.DINENSION ROOF SLOPE OVER 12 • 1 1 � (i' - i t2 11 g 19z- - 2'2 • 114 26 - 3'2 • 1118, 29j' - 4" +4'2 MIN AT RIDGE VENT SECTION Q PANEL PEAK POSITIVE REACTIONS ARE IN THE SAME DIRECTION AS THE DIAGRAM ARROWS_ NEGATIVE DIRECTIONS ARE IN THE OPPOSITE DIRECTION TO THE ARROWS. `COLL" IN THE ABOVE TABLE IS THE COLLATERAL LOAD, INCLUDING ANY SPRINKLER LOADS. "WIND LEFT IS WIND FLOWING FROM LEFT TO RIGHT ACROSS THE FRAME AS SHOWN. "WIND RIGHT' IS WIND FLOWING FROM RIGHT TO LEFT ACROSS THE FRAME AS SHOWN. IF THE VALUES FOR WIND RIGHT ARE ALL 'O.O-, THE FRAME IS SYMMETRICAL, AND ONLY WIND FROM THE LEFT WAS USED FOR ANALYSIS WIND LONG IS WIND FLOWING IN THE LONGITUDINAL DIRECTION, WHICH WOULD BE IN AND OUT OF THE PLANE OF THIS SHEET, PERPENDICULAR TO THE FRAME AS SHOWN MANY BUILDING CODES HAVE MORE THAN ONE SET OF DESIGN WIND 3 __ COEFFICIENTS FOR WIND IN THE LEFT AND RIGHT DIRECTIONS THE 1" AND "2' FOLLOWING THE WIND DESCRIPTIONS ARE DIFFERENT WIND CASES FOR THAT WIND DIRECTION. IF THE REACTIONS FOR THE SECOND WIND A AT 3' - 10] 3--53-181 1 -2 CASE ARE ALL '0.0 . THEN THAT BUILDING CODE ONLY USES ONE WIND CASE. FRAME CROSS SECTION COLUMN LINES 7 - 9 REFERENCE: REV DATE DESCRIPTION BY CHKD A 10.20.971 FOR APPROVAL BN r_ G 4 -_ -SETS IS SEISMIC LOAD. TURN -OF -NUT TIGHTENING CONNECTIONS FOR RIGID FRAMES MUST BE PROPERLY PRE - TENSIONED. THE SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS DATED NOVEMBER 13. 1985 (FUTURE REFERENCE TO THIS SECTION IS TO BE CALLED THE CODE) RECOGNIZES FOUR METHODS TO PROPERLY TIGHTEN THE BOLTS -1) "TURN -OF -NUT, 2) CALIBRATED WRENCH, 3) ALTERNATE DESIGN BOLTS AND 4) DIRECT TENSION INDICATOR. ALL OF THESE METHODS REQUIRE SPECIAL BOLTS AND /OR EOUIPMENT TO INSTALL. EXCEPT THE TURN -OF -NUT METHOD. THIS IS WHY WHIRLWIND SPECIFIES THIS METHOD FOR BOLT INSTALLATION. ACCORDING TO PARAGRAPH 7(c) OF THE CODE. WASHERS ARE NOT REQUIRED TO BE INSTALLED. EXCERPTS FROM THE CODE FOR INSTALLATION COME FROM PARAGRAPH 8(d): 'BOLTS SHALL BE INSTALLED IN ALL HOLES OF THE CONNECTION AND BROUGHT TO A SNUG -TIGHT CONDRION. SNUG -TIGHT IS DEFINED AS THE TIGHTNESS THAT EXIST WHEN THE PLIES OF THE JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEIN IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD WRENCH. SNUG TIGHTENING SHALL PROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART OF THE CONNECTION TO THE FREE EDGES. AND THEN THE BOLTS OF THE CONNECTION SHALL BE REnGHTENED IN A SIMILAR SYSTEMATIC MANNER AS NECESSARY UNTIL ALL BOLTS ARE SIMULTANEOUSLY SNUG TIGHT AND THE CONNECTION IS FULLY COMPACTED. FOLLOWING THIS INITIAL OPERATION, ALL BOLTS IN THE CONNECTION SHALL BE TIGHTENED FURTHER BY THE APPLICABLE AMOUNT OF ROTATION SPECIFIED IN TABLE 5...' TABLE 5. NUT ROTATION FROM SNUG -TIGHT CONDITION. BOLT LENGTH (FROM UNDER SIDE OF HEAD TO END OF BOLT) UP TO AND INCLUDING 4 DtAJAETERS ....... ............................... 1/3 TURN OVER 4 DIAMETERS. BUT NOT EXCEEDING 8 DIAMETERS ....... 1/2 TURN OVER 8 DIAMETERS. BUT NOT EXCEEDING 12 DIAMETERS ..... 2/3 TURN xei 't STEEL DESIGN OT41T NO OTI IER CODE REQUIREMETM, ARE INCLUDED WHIRLWIND STEEL BUILDINGS 8234 HANSEN HOUSTON, TEXAS 77075 -1089 (713) 946 -7140 DESCRIPTION FRAME CROSS SECTION B.J. WIRTH CORPORATION CARMEL, INDIANA WELDED RIGID FRAME 1:12 ROOF SLOPE CARMEL, INDIANA