HomeMy WebLinkAbout05040007-Site PlanCeri,eraUon t~iueexl~
C, eei~
FAX
F
]his Plot Pl.n Prq~red F~ R.H. of Indim. Plot Plan Legend
St~f~d P~ ~.0 [xis-~ing ~edes
[ * Approx. Lateral L~ation
INS~ ~ 200500009385 · ~ ~nitery ~wer ~es
~ ~ H {~ ~'t" v ~ Water S~vice Lines
~ 20,, ~,R~ · aonh~e (~nitory ~ Sion)
13731 STANFORD DR ~ (50 R~ ~ ~ee~¥, I~1~[ (st~)
Prepared Dote: 03/22/05: B~JKII D End S~fion (Stem)
P~ ~s): ROBERT GREENWALD ~ r~e ~r~t
......... tclow Line of swale
Building Uno (~ / B~)
~munity R~sMcfi~s: ....... [onem~t Uno
· de Yard =3
Rear Yard = N/A
Aggregate = 6~(B,N.)
R.H. of Indiana
Finished Floor Elevation Information
Pod Oracle = 915.1 per plan
Garage FIE + 1,5' = ,ReSidential FI~ (917.5)
Residential FFE - 9.0 = Basement Ftc[ (908.3)
Note: ]he gara§e tint.ed {th~ elevation
is 1.3' above the curb at the driw. per plan
1' from property fine,
4'from bock of cum,
per plan.
Sod Gaiculations:
Drive = 515 SF+ TC=915.20
Public Walk = 194
Private Walk =41 SF:i
=2,057
Sod = 220 SY:I:
Rear of residence.
Note: Sanitary Sewer
Top of Casting Information
Upstream Uonhole, TC= 915.20
Downstream Uonhole, TC=915.20
per plan,
Note:
This drawing is based on constmcUon plans or record drawings,
and is not based upon a field survey, '[he Schneider Corporation
does not warrant the dccurdcy or sufficiency of this informaUon.
Contractors should verify existing conditions prior to any
construction, Any discrepancy found on this drawing should be
reported to The Schneider Corporation immediately, failing to do
so results in the contractors assumption of all liability.
Note:
Per Cannel zoning ordinance 26.1.1:
The residen[~ district limits bei~ht to iwonty-6ve
feet (25'), hownver a dwelling may be increased in he{4ht
to th{fly-five feet (35') provided the side and rear yards
are increased an add{linnet one foot (1') for each
one foot (1') the structure exceeds the first
twenty-five feet (25') in height.
Lot # 81
¥B05.00307 4
Assumed North
Scale: 1" = 30'
Note:
]he bose"hoot devotion, depicted hereon, has been determined
end b~sed upon the pad gredon and/or contours token from the
construction plans for this subdivision. Unless sthted, no informoUon
~;~sut fluctuating water toples, so~ conditions, or on~ types has been
provided or stated on onid pinns. {t is recommended that the basement
fro{shed floor elevations be at toast two feet (2') above the normal
puel devotion of any edjoining bodies of water, unless o study of iocth
reve~s otherwise, if during the excavotinn process any ground water is
· tthessed, The Schneider Co~po~atinn should be notified immediately,
]he basement elevation should be raised two fuel (2') above the ground
wale', end addiUonel construction technkiues should be incorporated to
Deth~ 0f (;round/Storm
Wote~ flow pattern fo,'
individual lots,
Note: Burda' to ensure
positive drainoga away
from structure(s).
~l{evioth future problems.
Note:
Sump pump(s) to be pieced by
builder os needed.
PLAN
Flood Hazard Statement: The accuracy of any flood hazard data shown on this repod is subject to
map scale uncedainty and to any other uncertainty in location or eievaiion on the referenced flood
insurance rate map. ALL of the within described land DOES NOT LIE wilhin that special flood hazard
zone A as said land plots by scale on flood insurance rate map # 180081 0205F for City of Carmel,
Indiana (maps dated February 19, 2003).
i
FLOOD HAZARD STATEMENT
CERTIFICATION
~ .--~....'Lo .,
s0 03
~ ~ STATE OF