HomeMy WebLinkAbout05030230-Signed conditionalPERMIT PLAN REVIEW STCPS PAGE 1 PERMIT NUMBER: 05C30230 - SERGIO BUEZO TYPE: RESPOOL ~ARCEL ID : 1610330020010000 PARCEL ADDRS : 12071 BAYHILL DR CARMEL, IN 46033 APPLY DATE : 03/3C /05 ISSUE DATE : 2/0 DATE : CONTRACTOR : BURTON POOLS. LLC PHONE NUNBER : /765 420-0481 FAX NUMBER : 76~ 420-798 REVIEW STOP: BLDG BUILDING INSPECTOR REVIEW REV NO: t STATUS: C DATE: 04/13/05 CeNT ID: REVIEW SENT BY: ~ochs DATE: 04/13/05 TIME: 09:49 TIME SPENT: 0.00 REV RECEIVD BY: }ochs DATE: 03/29/05 TIME: 09:49 SENT TO: REVIEW MOTES: 2005-04-13 10:03:17 CONDITIONS OF PERMIT: 1. Water fall pump muse be SFCI DroLec~ed. 2. NO -unction boxee for oDEic lichting wiEhin 4 feet of pool or wanez fall edce.. 3. DisconnecEs for eculDemen~ must be within SIGHT and 50 feet cr less from eculomenL. 4. Bondinc of all deck reenforcemenE, handrails, divlnc board mounss and ~1~ mesal obJecEs within ~ feet of the edce muss be on the cc mmon bondin~ crid. 5. Disconnect for spa muse be a m~n. Df 5 fee5 from spa edce. ~. Cover switch must Drovzde full v~ew f POOl before closinc. 7. Po~,t ledce detail does no5 show a handhbtd around the pool edge ~rovide handhold, 8, NOTICE; Ail undercround eiectrical ~nd Dlumbinc muse be inst~lled on ondine and crounding ~nspecs~on and open for lnsDecLlo~. Ail ~uncE1oL boxs muse be see w~Eh exposed inter~ors and all wir~nc run~ Panel board musu be installed and ali conductors Eerminated on neutral ~n~ cround bus. CONDIT ONAL ENCOMPASS - Pentamation permit.4ge permit5.4gl) RUN DATE:04/i3 3~