HomeMy WebLinkAbout1270.97.5M
0
ID
in
N
N
0
N
m
Q
N
0
N
O
M
S
in
/
i-
u
U
W
0
O
d
31-014
3250
12' -51/2"
4"
MEDIA
OPT. 325 ALCOVE
L O F T
CPT., 8' CLG.
2'-i"
3fo HT. KNEE- = 5 0-44•
WALL, SANDARD
(OPT'L. WD. RAIL) 66�
v-011
rn
OPEN TO
LOFT OPT. 325
03-SCALE - 1/4" =1' -0"
n ft 5th BEDROOM
V ` SCALE:
STUD SPACING NOTE:
STUDS M ALL EXTERIOR WALLS AND INTERIOR
LOAD - BEARING WALLS SHALL BE PLACED 0 16" O.C_
STUDS IN ALL INTERIOR NON -LOAD BEARING WALLS
SHALL BE PLACED 0 24" O.C., UNLESS NOTED OTHERWISE.
36" HT. KNEE -
WALL, STD.
(OPT'L. WD. RAIL)
'AG CHASE
OPT. 351
1/4" =1' -0"
0
m
4'
-A I
N �
I W
0I
SOLID BLOGKIWG NOTE:
ALL POINT LOAD SUPPORTS (JACK STUDS) TO BE CARRIED
THROUGH EACH FLOOR LEVEL TO SOLIDLY BEAR ON FNDTN.
SYSTEM (OR OTHER STRUCTURAL MEMBER). PROVIDE SOLID
BLOCKING IN FLOOR SYSTEM BELOW ALL POINT LOADS.
ROOF GIRDER
TRUSS ABOVE -
(2) JACK STUDS
EACH END—,
30' -0" OVERALL
24' -0"
A4.1 j
FIBERGLASS j
TUB /SHWR UNIT 1
3250 '¢ 3250
m
BDR-1. 4
OPTIONAL
(OFT. 325i i v
51 Oil
HALL
BAT" v
8' CLG.
- - -- �6 T
8 c.
66
-----------
I�
4"
BEDROOM 3
•�,
%A►n o
\t`
4' -(o
CV) Z
d)
UJALK-IN U7
CLOSET .► WALK -IN � tY
T
(y GLOBE
CPT., 8' GLG I cv
N
3' -r L y 9' --1
-�T BEDROOM 2 -
CARPET, 8' GL G-
i 411
10il
HVAC CHASE
- NOTE-. FURR -OUT WALL if
6" Ui/ SLAB PLAN GAS --
FURNACE ONLY-7
/ ------------
� - --
- - - - - -� I 3040 -- — - -- - -- 3036
3250 - i - - -- ( GAS FLUE LOCATION
i ( W/ SLAB PLAN ONLY —
I (AWzLE BACK TOWARDS
— .-� — — — WAR OF HOUSE IN ATTIC)
I
f l
.1
I i
30' -0" CVERALL
LINE OF FIRST
FLOOR BELOW -�
I �
I I
l I
I I
I I
I I
I I
L------------ - - - - - - - - - - - - -1
0 1 SECOND FLOOR PLAN B
SCALE: -- - -- 1/4"
m
6
gA
Lut
4
m
C. C
0
o
Z
0
U !
OPT'L. \\
FIREPLACE \�\\
F-
(OPT. 802) \\
Cv
36" HT. KNEE -
(
WALL. STD. - - -�
p
(OPT'L. WD. RAIL)
Y
m
OPEN TO
Q
BELOW ---\
�
OPTIONAL
_�
BDRM.5
F
Z
�v
w
Q
Ld,
V
PLANT LEDGES
��
a`9' -! 3t4" HT, AFF.-
-----------
I�
4"
BEDROOM 3
•�,
%A►n o
\t`
4' -(o
CV) Z
d)
UJALK-IN U7
CLOSET .► WALK -IN � tY
T
(y GLOBE
CPT., 8' GLG I cv
N
3' -r L y 9' --1
-�T BEDROOM 2 -
CARPET, 8' GL G-
i 411
10il
HVAC CHASE
- NOTE-. FURR -OUT WALL if
6" Ui/ SLAB PLAN GAS --
FURNACE ONLY-7
/ ------------
� - --
- - - - - -� I 3040 -- — - -- - -- 3036
3250 - i - - -- ( GAS FLUE LOCATION
i ( W/ SLAB PLAN ONLY —
I (AWzLE BACK TOWARDS
— .-� — — — WAR OF HOUSE IN ATTIC)
I
f l
.1
I i
30' -0" CVERALL
LINE OF FIRST
FLOOR BELOW -�
I �
I I
l I
I I
I I
I I
I I
L------------ - - - - - - - - - - - - -1
0 1 SECOND FLOOR PLAN B
SCALE: -- - -- 1/4"
m
U
(a
u 0
� L uL
o�''m 0�tl
Q fa U) 0
p>003-130 -Z E
m?'.T�' -a o 0 IS
O 61 Q v
L V
�OQQ�m�dc
6
gA
4
m
C. C
0
o
Z
0
-A
c
Y
O
Q
Q
�
F
Z
�v
w
Q
Ld,
V
0:
��
m
a
�
� e
X
Q
�
w
_
u_
0
0
�
_
n
C3
_
r
U
(a
u 0
� L uL
o�''m 0�tl
Q fa U) 0
p>003-130 -Z E
m?'.T�' -a o 0 IS
O 61 Q v
L V
�OQQ�m�dc
i�
f
Zz
gA
4
m
C. C
0
o
Z
0
-A
ca
O
Q
�
F
Z
�v
p
Ld,
V
0:
��
a
�
� e
X
i�
f