HomeMy WebLinkAbout1334.97.12TYPICAL ROOF
CONIIRU11081
6'186' P.T. WOOD SLEEPER
LENGTH AS REQUIRED TO
BEAR ON STEEL ANGLE FRAME
MDOtA1E ROOFING
PROTECTION LAYER
MEINTjRIM' ROOFING
F.RP.T. WOOD BLOCKING
2' WIDER THAN SUPPORT J
SLEEPER DETAIL
SCALE: = 1' -0'
ROOF
HATCH
15' -8'
STEEL LADDER-.2 1/;
3/6' FLAT STRINGIER
W/ 5/8' DUL RUNG
ATTACH TO WALL A:
FLR W/2 1/2'x1/8'
94APED BAR BRAOI
BOLT LADDER TO WO
BACK-UP N WALL
DECK 9• -0. DECK
LADDER DETAIL "' `
SCALE: = 1' -0 GC. TO INSTALL
IN MOORE APPRAISAL'S SPACE HASP d CORED PADLOCK.
ROOF
HATCH
o�
�r
c
0
a
cu
a:
a
y
0
z
Q
0
0
cc
6>
S
E
U
3
Q
598 WEST CARMEL DRIVE DETAILS
WALKWAY PAD DETAIL
SCALE: - 1' -0'
UNIT FLASHING
SEALANT
TERMINATION BAR
FASTENED TO CURB
21(10 FAR P.T. WOOD CURB
FLASHING MEMBRANE
LAP SEALANT
FR.P.T. WOOD BLOCIINIG
FASTENER 12' O.C.
OPENING SUE PER UNIT REOWEIENTS
COOED. ROOF OPENINGS W/ MECH -DIGS
BOOR CURE 0 GOOSENECK VENT
SCALE: = 1' -0'
m
RNIT FLASHING
mim ROD SIM
AOIEJtED N PLACE
SEALANT
TERMINATION BAR
FASTENED TO CURB
INSULATED UNIT CURB
FLASHIG MEIHtALE
LAP SEALANT
F.R.P.T. WOOD BLOCKING
FASTENER tY O.G
STEEL JOIST - SEE
STRUCTURAL DOM
ROOF CURB 0
HVAC UNIT & RWF HATCH
SCALE: = 1 -0
ROOFING N®TES :
I. ROU94 t INSTALL A ROOFING
SYSTEM N STRICT COPLIANCE W/
SPEOFICAT06 REFER TO DN. 7. SPC -1
2. PERFORM ALL ROOFING WORK N ACCORDANCE
W/ MANUFACTURER'S RSJ9E0 VECFIGITIONS
t DETAILS
3. FOR ROOF PENETRATIONS COOIIOINATE W/
STRUCTURAL MECHANICAL t PLMW OtAWNGS
SEE SPECIFICATIONS
4'
VENT STACK
FLA SHING
NG J SEALANT
TREATMENT
FLAB
BASE FLASHING VENT STACK
VENT STACK DETAIL
SCALE: = I. -0'
THESE PLANS ARE INTENDED FOR "GU DELINE" BID AND CONSTRUCTION
PURPOSES ONLY, AND DO NOT INCLUDE DETAILS AND METHODS OF
CONSTRUCTION FOR ALL AREAS. SUBSTITUTIONS OF MATERIALS AND
METHODS MAY BE PROVIDED, UPON APPROVAL OF OWNER AND ARCHITECT.
THIS ARCHITECT CANNOT GUARANTEE AGAINST HUMAN ERROR, OMISSIONS
OR INACCURACIES CONTAINED WITHIN THESE DOCUMENTS.
ALL CONTRACTORS AND SUPPLIERS MUST VERIFY ALL DIMENSIONS AND
DETAILS FOR THEIR WORK, AND REPORT ANY DISCREPANCIES TO THE
ARCHITECT PRIOR TO FINAL BID, FABRICATION, CONSTRUCTION AND
INSTALLATION OF ANY MATERIAL.
EXHAUST STACK
4.
FLASHING -� I I�StEEVETFASNEo
BASE FLASHING TO MTL ROOF DECK
FLUE STACK DETAIL
SCALE: = 1' -0'
I:ZiZ�7�,A_1�
SCALE: 1/16" — l'—O"
8" PREFIN. ALUM 'BOX' GUTTER - TYPICAL
6^ PREFIN^ ALUM. DOWNSPAOUTSr0 35' MAX. - TYPICAL
f
W
D
J
W
Q
U
H
W
0)
Lo
O
to
•
hd
O
w
P p
�• O w M
X N
INC
CERTI. FIED
tANA
is
4428 3
STATE OF
AIIA
DRAWN
CHECKED
D.E.A.
REVISIONS
DATE
9/3/97
PROJECT NO.
SHEET TITLE
SHEET
A-