Loading...
HomeMy WebLinkAboutLS.1 LIFE SAFETY.pdfProject Number: Revisions: Drawn By Checked ByIssue Date Architecture / Project Managment: Sheet Number: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) Architect: Sheet Title: Project: Developer: By: SI L V E R D O O R S P A Ca r m e l C i t y C e n t e r - S u i t e 6 4 76 2 S . R a n g e l i n e R o a d , C a r m e l I N 4 6 0 3 2 COPYRIGHT & OWNERSHIP OF DOCUMENTS Check Set: 9.21.2012 State Release Set: 9.28.2012 N 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP SCALE: 1/128"= 1'-0" KEY PLAN SUITE 64 PEDCOR DESIGN GROUP LS.1 LIFE SAFETY AJR MC9/28/2012 THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2012 JAMES R. STUTZMAN, AIA, Carmel, Indiana. N UP UP 19 R @ 6 2 5 / 3 2 " = 1 0 ' - 8 3 / 4 " 18 T @ 1 1 2 9 / 6 4 " = 1 7 ' - 2 3 / 6 4 " UP R.6 9 C 1 2 RAMP UP 1:12 RA M P U P 1: 1 2 Fire Command Center FFC 1 RA N G E L I N E R O A D PE OP PE PE PE PE PE OP OPOP OP OP OP FIRE COMMAND CENTER BUILDING A SCALE: 1" = 20' 1 PHASE I LIFE SAFETY PLAN LS.1 WALL TYPES-FIRE RATINGS 1 HOUR RATED 2 HOUR RATED 3 HOUR RATED EGRESS PATH EXITS AND LOCATIONS BE PE PARKING EXIT BUILDING EXIT OP ORIGINATION POINT CARMEL CITY CENTER -PHASE 1 BUILDINGS 2. HORIZONTAL FIRE SEPARATIONS: ASSEMBLIES SEPARATING THE GARAGE PARKING LEVEL AND FIRST FLOOR OF BUILDINGS ABOVE IS THREE HOURS(3HRS.) ASSEMBLIES SEPARATING THE GARAGE PARKING LEVEL AND PLAZA ABOVE IS ONE AND ONE HALF HOUR (1 1/2 HR.) ASSEMBLIES SEPARATING THE FIRST FLOOR OF BUILDINGS AND SECOND FLOOR ABOVE IS TWO HOURS (2 HRS). CONSTRUCTION DESIGN RELEASE SHELL & CORE PROJECT NUMBER: 317796 RELEASE DATE: 06.19.07 SILVER DOOR SPA - BLDG A PARKING LEVEL CITY CENTER DRIVE BE