Loading...
HomeMy WebLinkAboutA1.1.pdfGENERAL DEMOLITION NOTES: A. MAKE ALL DEMOLITION CLEAN AND COMPLETE AND IN A MANNER SUITABLE TO ACCEPT NEW FINISHES AND� OR SURFACES. REFER TO ARCHITECTURAL PL4N5, SPECIFICATIONS, AND DETWLS FOR SPECIFlC WFORMATION REGARDMG APPLICATION OF NEW MATERWLS. 8. REMOVE EXISTING FLOOR RNISHES, AREA AS SHOWN ON PLANS, OR AS REQUIRED FOR NEW CONSTRUCTION WORK. REMOVE FLOOR FlNISH ADHESIVE AND PREPARE SL48 AS REQUIRED TO RECIEVE NEW FlNISH. MAKE DEMOLITION CLEAN AND COMPLETE IN A MANNER SUITABLE TO ACCEPT NEW FlNISHES AND/ OR SURFACES C. VERIFY FLOOR ELEVATIONS ON EITHER SIDE OF WALLS BEING REMOVED. PATCH THE FLOOR AND INSTALL AND EPDXY FlLL MATERIAL AS MAY BE REQUIRE� F042 A LEVEL FLOOR CONDITION. D. WHEN DEMOLITION CAUSES OR ExPOSES DAMAGE TO FLOOR SLAB, WALL, OR CEILING SURFACES WHICH WILL REMAW EXPOSED IN THE FlNISH WORK, THE CONTRACTOR SHALL REPAIR AND LEVEL SUCH CONDITIONS SUITABLE TO RECIEVE NEW FlNISHES. E ALL DEMOLITION ITEMS SHALL BE CONSIDERED THE PROPERtt OF THE OWNER UNTIL SUCH A TIME AS VERIFlCATION HAS BEEN MADE AS TO THOSE ITEMS NOT TO BE RETAWED BY THE OWNER PRIOR TO REMOVAL FROM THE SITE ALL ITEMS NOT TO BE RETAMED SHALL BE REMOVED COMPLEfELY FROM THE SITE BY THE GENERAL CONTRACTOR. E THE GENERAL CONTRACTOR SHALL PROVIDE ALL TEMPORY PARTITIONS AND TEMPORARY DOORS AS INDICATED ON THIS DEMOLITION PLAN OR AS DEEMED NECESSARY BY ARCHITECT AND OWNER. THEY SHALL BE MAINTAMED, WITH ANY DAMAGED REPAIRED IMMEDIATELY, TO AVOID MIGRATION OF DUST INTO THE ADJOINING AREAS. G. GENERAL CONTRACTOR TO VERIFY DUCTWORK OR PIPWG PENETRATIONS THROUGH WALLS ABOVE CEILING. IF PENETRATIONS OCCUR AND DUCTWORK OR PIPING IS REMOVED OR RELOCATEq FlLL IN OPENINGS TO BE FWSH WITH AND OF THE SAME MATERIALS AS THE SURROUNDING WALL H. ALL ITEMS SHOWN DASHED, AND NOT OTHERWISE CALLED OUT, INDICATE EXISTING WALLS TO BE DEMOLISHED. REMOVE SUCH WALLS TOTALLY AND COMPLETELY UP TO STRUCTURE ABOVE. I. GENERAL CONTR.4CTOR IS RESPONSIBLE FOR LOCATING AND PROVIDING TEMP. OR PERM. SUPPORT OF BEARING WALL AND ROOF TRUSSES DURING DEMOLITION AND NEW CONSTRUCTION. GENERAL CONTRACTOR TO CONTACT PASSACANTANDO ARCHITECTS IF CONFLICT OF BFARING PARTITIONS CONFLICTS WITH NEW LAYOUT. DEMOLITION NOTES: A. REMOVE ALL EXISTING CMU BLOCK WALLS SHOWN DASHED REPAIR AN� PATCH FLOORS TO RECEIVE FLOOR COATING 8- REMOVE AND RELOCATE EXISTING OVERHEAD DOOR. REPLACE ANY DAMAGED PARTS AS REQUIRED C- REMOVE AND RELOCATE EXISTING MAN DOOR D. REMOVE AND RELOCATE EXISTWG DOUBLE DOORS E. REMOVE EXISTING OVERHEAD DOOR AND TRACK F. REMOVE EXISTING FLUORESCENT LIGHT FlXTURES IN THIS AREA. REFER TO LIGHTING PLAN FOR NEW FIXTURE LAYOUT G., REMOVE FACE BRICK AND STONE FROM WEST WALL OF OIL STORAGE ROOM H. CUT NEW OPENING W EXISTING WALL TO RELOCATE EXISTING DOOR AND FRAME QNSTALL NEW LINTEL TO CARE WEIGH OF WALL ABOVE) SYMBOL LEGEND WALLS TO BE REMOVED °�'� EXISTING WALLS TO REMNN ��� EXISIING DOOR FRAME AND HARDWARE TO BE REMOVED I VA � EXISTING DOOR FRAME AND HARDWARE TO REMAIN SYMBOLS x XX x XX CORRIDOR 100 DETAIVSECTION DESIGNATION SECTION NUMBER SHEET NUMBER ELEVATION DESIGNATION SECTION NUMBER SHEET NUMBER ft00M DESIGNATION ROOM NAME ROOM NUMBER DOOR DESIGNATION o DOOR NUMBER �� EXISTING DOOR WALL DESIGNATION � WALL TYPE ExISiING wALL DOOR/ HARDWARE SCHEDULE DOOR DIMENSIONS TYPE CONST. MAYL FINISH HDWR ELEV. RATED REMARKS N0. WIDTH HT. THK. SET D-1 EX EX EX EX EX EX EX - - - RELOCATED DOOR AND TRACK D-2 EX EX EX EX EX EX EX - - - RELOCATED DOOR/ HARDWARE/ FRAME �-3 EX EX EX EX EX EX EX - - - RELOCATED DOOR/ HARDWARE/ FRAME �-4 3'-0° 7'-0" I 3�4 FLUSH SOLID CORE MTL PAIMED � - - MATCH BUILDING STANDARD D-5 10'-0" 1' - - - - - - OVERHEAD DOOR/ MATCH BUILDING STANDARD D-6 b'-0' 7'-0" I 3�4 FWSH SOLID CORE MTL PAIMED 2 - - MATCH BUILDING STANDARD D-7 (2)3'-0" 7'-0" I 3�4 FWSH SOLID CORE MTL PAIMED � - - MATCH BUILDING STANDARD DOOR SCHEDULE NOTES 1. ALL HARDWARE i0 MATCH BUILDING STANDARD 2 SURFACE CLOSER A. MATCH BUILDING STANDARD 3. HINGES A. STANDARD BUTTS: BB1279: HAGER B. E%TRA HEAVY BUTTS: BB1168: HAGER C- OOORS LESS THAN 3'-6" WIOE a i/z" x a i/2° (srnNOneo) D. DOOR 3'-6" WIDE TO 4'-0" WIDE 5� X 4 1/2" (EXTRE55) E USE S�AMLESS SiEEL ON EHTERIOft �OOftS 4. EXIT DEVICES (VON DUPRIN, SARGENT): A. NON UBELED DOOR: i) siNC� 000R (no��aw Mern�) VON DUPRIN 9975NL (MORiISE DENCE) 5. ALL DOOR FRAMES TO BE WELDED IAETAL FRAMES UNLE55 NOTED OiHERWISE. HARDWARE SETS: HARDWARE SET �I BUTf HINGES EXIT DEVICE W� LOCKSET SURFACE CLOSER THRESHOLD WEATHER STRIPPING OVERHEAD DRIP GUARD HARDwARE SEi j�2 BUTf HINGES PASSAGE SURFACE CLOSER THRESHOLD weamea srRiPPiNc OVERHEAD DRIP GUARD , GENERAL NOTES A. ALL WORK ON PROJECT MUST COMPLY WITH ALL APPLICABLE WRREM LOCAL, STATE AND NATIONAL CODES B. EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, DUST PARTITIONS, ETC. AS REQUIftED BY L4W AND AS OTHERWISE REQUIRED C. EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, PALLETS, PACKAGING, UNUSED MATERIALS, TRASH MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THHE JOBSITE D. VERIFY ALL EXISTING CONDITIONS PRIOR TO THE START OF CONSTRUCTION. NOTIFY DESIGN POINT, INC- IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDWG WITH WORK. E. ftEVIEW ALL DRAWINGS (PLUMBMG, ARCHITECTURAL, ELECTRICAL, HVAC) CONCERNING SLEEVES, OUTLETS, BOXES, ANCHOR VENTS, OPENINGS, ETC. THAT MAY BE REQUIRED. EACH RESPECTIVE TRADE IS RESPONSIBLE FOR PROVIDING AND INSTALLING THESE ITEMS. F. NIC ="NOT IN CONTRACT" GA. SHALL COORDINATE AND VERIFY AS TO BLOCKING, HOOK—UP, AND OTHER REQUIREMENTS WITH TENANT. G. ALL SUBCONTRACTORS SHALL PROVIDE SHOP DRAWINGS TO DESIGN POINT WC. FOR REVIEW ON PRODUCTS OR WORK PRIOR TO FABRICATION. H. CONTRACTOR TO PROVIDE BLOCKING IN WALL AT ALL WALL MOUNTED CASEWORK I. PWMBWG CONTRACTOR TO PROVIDE CUT SHEETS OF PWMBING FlXTURES FOR APPROVAL, PRIOR TO INSTALL4TION. J. FLOOR TO BE CHALKED AND APPROVED BY ARCHITECT AND OWNER PRIOR TO CONSTRUCTION OF METAL STUD WALLS K. ALL DIMENSIONS TAKEN TO FACE OF ME�AL STUDS UNLESS NOTED OTHERWISE PLAN NOTE �1 INSTALL 6" STEEL BOLL4RD 42" TALL (FILL W� CONCRETE AND PROVIDE BOLLARD COVER) �2 WRLL EXISTING OPENING (MATCH CONSTRUCTION/ TOOTH IN MASONRY) �3 12 COURSE CMU BLOCK WALL (ReFeR ro srRUCTURa�) 2 A3 ro i 0 0 � � 0 0 i w � 4 i � 0 n D-7 I 3 A3 r � II� ' --- ' L— n�l—� i i � I� I�i � � � i�i — ii� li II I I' � �I�I . u�I�-� I I� . � L� . �L—� �L u --L— ... I� �� 4 A3 b�� �� E II �I I� I 3 � I II II . I � I . � I � I � I � � ��r'�'J I �� I I I I � ii I�,, r ii I I i ,.��;,, i i �a i,� i �����e i i �{ i y 7�� p i i 7p � I � Ho 9� � I I k � � I H� 4� � Q I I Fd �I � A � � I I � � � � � I I � � I � � �� I . . I. . I I I I I � ---- ���-�---- I I��II � � I I II �I U b c io — 1 I � �O � � � � �. � I � �� I I I �i i i i i i �� � � � � �� � � � 'i � � �� �� � � gp p� �p �� pg � � � �� � ' � � ', � �p ', � � ���. r,�,�%��k�.' I:,�,���":1 i�I`:��';;: I� CIH I�� �� � _ i i i ;� "� ��i �i :,� �i i i i �i i I I I I I I � I I I I �� � Ili i i I iii I i i � ��� 1 DEMOLITION FLOOR PLAN SCALE 1�8" = 1'-0° OO � � V . n r °m v � � 0 N > rv `o o � � � M H � Z � — � O a d � 0 Z m � C � v � y C � aa c (n y o W L U O a U N m N � `m m°5 v \ �G�iiFiisi/i,i,,� . \ ��p����STfRF"�'9�!'� 19600042 � STATE OF � / � pp1P � � ,4� � : °'' ��� i T ����� i� ocr �i � V6 � � � O � � � r � � l � � _ � U Q � � � � � � _� ���� r� �— �J � (� � � w ° � � � � � � � 00 Q ���U nnTe� 31 AUG sca[.s� AS NOTED n�u,wiv� NYE REVISIONS� Fi NOV 1Z All ideas, designs, and plons indlwted or represented by these drawings are owned by, and the property of Design Poin�, Inc Conhactors shall verily ond be responslble for all 4lmenslons on the job site. AIl rights reserved, excapt for uses eryressly permitted in writing; 'mlormation shown or included on these drawings are solely the pmputy of Design Point, Ine. DRAWING NAME+ DEMOLITION� FLOOR PLAN PRQTECT� SHEET� A1.1