Indiana Residential Code Section R-317.1.1. Alterations, and additions. When interior
alterations, or additions requiting a permit occur, or when one or more sleeping rooms are
added or created in existing dwellings, the individual dwelling unit shall be provided with
smoke alarms located as required for n.e.w dwellings; the smoke alarms shall be
interconnected and hard wired. Exceptions: Smoke alarms in existing areas shall not be
required to be interconnected and hard wired where the alterations or repairs do not result
in ~he removal of interior wall or ceiling finishes exposing the structure, unless there is an
attic, crawl space, or basement available which could provide access for hand wiring and
interconnection without the removal of interior finishes.
S/permits/TRANSMiTTAL sheets for plan review
ENIOMPASS NOTEPAD - 04/08/05
NOTES FOR: (5040044 BLDG 1 PR
PAGE
DATE TIME
NOTE TEXT OPEPATOR
1. show weep holes and spaclnq in brick /whohlt
2. show size of anchor bolts in sill
plates and also ~o go into 2nd coarse
of block
3.visqueen required in crawl space and
also under garage slab.
4. show method of achieving R-19 zn
wails.
5. show any existing hvac in garage sr .
new hvac for heating.
TOTAL LINES OF NOTES: t0