HomeMy WebLinkAbout1347.97.117116' ROOF DECKING
J„ SECTION AT WINDOW HEADER
150 PLAN det.esLJ17
Not To Scale
EXTENDED 3/4' DURA BOARD
INTO LOVER TRUSS BAY
THROUGHOUT THE ENTIRE
BONUS ROOM
low
i
I
3/4' OURA BOARD INSULATION
EXTENDED INTO LOVER TRUSS BAT
R-19 INSUL.
BONUS RM. TRUSS
20 BLOCKING
SECTION DETAIL
Bonus Room Truss
STYROFOME AIR
FLOW POCKET
R-30 INSUL.
5/6' DRYWALL
VAPOR BARRIER
112' DRYWALL
3 112' WALL INSUL.
3/4" UNDERLAY
R -30 INSUL.
SEE DETAIL ABOVE
dells
1
&FRONT SOFFIT RETURN
--750A det.J30
SIDING
112" INSULATION SHEATHING
4'
CABLE TRUSS (or
SLOPED WALL TRUSS)
Ix BAND BOARD
e/ DRIP EDGE -
SEE ELEV. FOR SIZE
BRICK VENEER
112' INSULATION SHEATHING
BRICK SOLDIER COURSE
JACK ARCH e/ KEYSTONE -
SEE ELEVATION FOR SIZE
AND LAYOUT
Ix TRIM e/ 2x6 BLOCKING
FOR BRICK SUPPORT - SEE
ELEVATIONS FOR SIZE /LAYOUT
BRICK BEYOND
2x6 TRIM
NAIL TO FIRST
COUMON TRUSS
2x6 / 16' o.c.
DOUBLE TOP PLATE
DRYWALL
TRUSS HEADER
2x6 CONTINUOUS NAILER
OVERHEAD DOOR
A61 SECTION at GARAGE O'HEAD DOOR
TRUSS HEADER 1 /BRICK det.e5tA61
1 112' = I' -0'
2x8 LEDGER NAILED
TO TOP PLATE
NAILS AT 6' O.C.
EXTERIOR CAULKING
7/16 O.S.B. SHEATHING
BRICK VENEER
CUSTOM SEAMLESS PAN
FLASHING W/ 2' BEND
7/16 O.S.B. SHEATHING
2x4 TOP PLATE
2x4 STUDS AT
F.P. CHASE
p37 SECTION at BRICK CHIMNEY CAP
of FIREPLACE CHASE det.e5tA37
BRICK
THRU -VALL 7/16' O.S.B. SHEATHING
STEP FLASHING 2x4 STUDS
PROVIDE I' MIN. Z
SPACE BETWEEN BRICK
AND WOOD NAILERS O
ROOF DECKING
(2)-26 W/ 112 SHIM
ATTIC SIDE PROVIDE 2x6 LEDGER
ANGLE LAG BOLTED TO BELOW STEEL ANGLE
0-24 AT 16' O.C.
SECTION at BRICK CHIMNEY CHASE
at ROOF LOCATIONS det.tsLA35
SECTION at BRICK CHIMNEY CHASE
at ROOF LOCATIONS
dot.eslA34
BRICK VENEER
3/4' RIGID INSULATION
CONT. 2x4 NAILER
R-13 BATT INSULATION
9/16'4 1/4' BASE TRIM
3M' DECKING
2x10 FLOOR JOISTS
AT 16' O.C. U1.N.O.)
DRYWALL CEILING
A23 EXTERIOR WALL at 2nd FLOOR
at BRICK LOCATIONS det.estA23
2x4 BLOCKING
BETWEEN STUDS
R-13 BATT INSULATION
2x4 STUDS
AT 16" O.C.
DRYWALL
3/4' RIGID INSULATION
1x2 WOOD TRIM
OR 'J" CHANNEL V/
VINYL SIDING
SIDING
A19 NV INSIDE CORNER DETAIL
at EXTERIOR WALL det.estAi9
3/4' RIGID INSULATION
Ix4 WOOD TRIM
Ix4 9000 TRIM
2x4 STUD WALL
DRYWALL
2x4 BLOCKING
BETWEEN STUDS
R -13 BATT INSULATION
6' HORIZONTAL SIDING
Al5 OUTSIDE CORNER DETAIL
BACK a HOUSE det.estA15
2x4 PLATE ANCHORED
TO STEEL BEAM STEEL BEAM
SEE FOUND. PLAN
OR SIZE
FLOOR JOISTS
I12' DRYWALL HVAC DUCT o
2x2 CDNT. WOOD
4' -0. I BLOCKING (TYP OF 4)
214 FLAT AT 16' O.C. ,1
unless noted ellerelss
A13 FRAMING at DUCT BULKHEAD
(2) -2x4 FRAMING TEEL ANGLE �J at FINISHED BASEMENT AREAS
FOR ROOF DECK LAG BOLTED TO
0-26 AT 16' O.C.
CHIMINEY CAP
I I ITO X T )1E' I TRUSS/RAFTER
BRICK SOLDIER
BRICK ROWLOCK
CHIMINEY
0 112,
TYP.
J26 750 PLAN SECTION
�— at CHIMINEY LOCATIONS x.t.WZ
(2)-2x4 VERTICAL NAILERS
FROM 2ND FLOOR PLATE TO
TOP OF TRUSS
BRICK
0 d 2x4 TRACK MOUNT OVERHEAD DOOR
TO CEILING Y OTHERS
112' DRYWALL
0-26 V/ 112' SHIM
A34 20 STUD WALL AT 16" O.C.
SEE FLOOR PLAN
SECTION at BRICK CHIMNEY CHASE
at ROOF LOCATIONS
dot.ostA33
1x2 WEATHER STRIP
112" INSULATION SHEATHING
BY OTHERS
BRICK VENEER 2x6 TRIM
2x4 JACK STUD CAULK BEAD
SECTION at GARAGE DOOR JAMB
at BRICK LOCATIONS
det.estA13
det.esLA2
�+ N
r � N
� N
W! n
r � �
Cs
to
a
�
W
liJ
E
C=
C
a
L
<
C)
d
m
U
f
CT+
J
0
L
O
U_
cn
�
0
0
W
C!7
C
L.
> -
C-0
r—
w
w
l!7
z
CD
o
Z
Z
3
CV
<
>
>
W
UJ
D
Cr
Cs
z
w
o_
E
C
a
L
<
C)
d
m
U
< I J
' W I Z
W Z
AD1
DATE:
z
w
E
C
Ci'i
L
<
Y
d
m
U
<
J
0
L
U_
O
L0
xT
W
m
C
L.
> -
C-0
r—
w
�
z
o
-
Z
a
AD1
DATE: