Loading...
HomeMy WebLinkAbout0622.97.3a N J E F . _ _ . _ _ _ _____ -_ _ _ - ____ = = _ _ _ ____ _ - 01 HOSKINS I ambitectural-'..' directibin i. consultatiot Custom Residential Planners & Designers FLOOR 40 PSF LIVE LOAD 10 PSIF DEAD LOAD OUTLINE OF WALL BELOW — — — — — — — — — — — — — -- — — — — — — — — — — — — — — — — 1337 Locust Street Middletown 11111110OF 30 P5F LIVE LOAD IN 47356 10 PSF DEAD LOAD (317) 354-2951 W. I.C. 4" %.Q xx3-'1q- 1/2, 4" Dabion PH -v1G412-(o Z c1ppv left I. THE CARPENTER SHALL CAREFULLY LAY OUT AND 22 x All R Jetrrev Wook4% . . lef%* Reswvod ERECT ALL STRUCTURAL MEMBERS OF ROUGH CARPENTRY. _0+00 not be 04opt FRAMING, SHEATHING, AND BRIDGING. ALL MEMBERS L -J or ��Oprt6b*&. SHALL BE PROPERLY PLUMBED, LEVELED, AND BRACED StR UNTIL ALL STRUCTURAL CONNECTIONS ARE IN PLACE. A SUFFICIENT NUM5ER OF NAILS, SCREWS, AND BOLTS SHALL BE USED TO INSURE THE RIGIDITY OF THE W. .33"x -12'- TUB - CONSTRUCTION BEDIRM '02 -q 2. FRAMING LUMBER SHALL CONFORM WITH NATIONAL -A DESIGN 5PECFIC-ATION6 FOR STRESS GRADE LUMBER 1W AND ITS FASTENINGS. PRE -EW-z WOOD TRUSSES A; J015T6 AND ALL OTHER: 24" O.C. NO-) DOUGLAS FIR LARCH OR YELLOW PINE 12'-4" F�- . 1450 Pei 0 3 1/2 FC - 1000 psi 6 E = 1,1roO000 pdl -41-1- FIRST FLOOR SILL PLATES, CRAWL SPACE FRAMING, AND STRUCTURAL MEMBERS EXPOSED TO WEATHER C-144ALL BE UJOLMANIZED PRESSURE TREATED. 2'4" 2 A, 4. ROOF TRUSS DESIGN, SPECIFICATION, AND ERECTION PROCEDURE TO BE SUPPLIED BY THE TRUSS —A 2 5. MICRO-LAM BEAM STRUCTURAL PROPERTIES, po a 2800 psi :FINISHED FC • 2 100 P61 ®' 4: E a 2000000 psi (4)- 50NUE) .11 CA 5HELVE5 LU 4- Co. PROVIDE DIAGONAL BRACING AT ALL EXTERIOR LU A CORNERS. R I AN Ul tY6 I A t -1. FRAMING OVER GIRDER AND FEARING PARTITIONS: LA JOISTS MAY BE BUTTED TOGETHER OVER THE CENTER BEARING, PROVIDING JOISTS ARE TIED TOGETHER OR A, -3'- 4' 31-&, 4 J015T5 MAY BE LAPPED AND NAILED TOGETHER MINIMUM LAP, 4 INCHESI MAX. OVERHANG, 12' v LU 2'4' 6. FLOOR J015TS SHALL BE DOUBLED UNDER EACH W. I.C. PARALLEL PARTITION. S. BRIDGING. MAXIMLIM SPACING BRIDGING SHALL MASTER 15E CROS-0tMOGING USING N3 INCH BOARDS OR SOLID BRIDGING OF .1016T DIMENVON. SOLID BRIDGING MUST SUITE BE SET IN AN OFFSET FASHION. 10. WALL 4 PARTITION FRAMING: UNLESS OTHERWISE -C., -j SHOWN, SPACE STUDS tv Iry " O.C. DOUBLE STUDS AT OPENINGS. CONSTRUCT PARTITION CORNERS WITH NO 4�1 'A; 1. LESS THAN �B FULL MEMBERS. WALLS AND BEARING SHOWERS ii '" s ii PARTITIONS SHALL HAVE DOUBLE TOP PLATES. v PLATE5 RE5T[W-s ON MASONRY CF CONCRETE SHALL BE �LUA L r7l 71 NUR5ERY p 14 ANCHORED WITH BOLTS OR METAL STRAPS. r /211 4" i; 11. GLUE 5U5-FLOOR USING RECOMMENDED ADHESIVE, APPLY GLUE MAD TO FRAMING AND ALONG PANEL GROVE EDGES, NAIL 1111 00 NAILS 0 12" O.C. TUW1 -120 VANITY 4 LU I D5J 12. PROVIDE NAILERS, NAILING STRIPS, AND GfROLNV6 AS NECESSARY AND RIGIDLY SECURE IN PLACE FOR ATTACHMENT OF TRIM, FINISH, AtC> OTHER WOW, OUTLINE OF WALL BELOW 13. J015T HANGERS ALL FLUSH BEAMS SHALL BE MIhL I& GALV STEEL, AND PROPERLY SIZED TO ACCEPT JOISTS.