HomeMy WebLinkAbout0635.97.4Wall Section Kev
1. SHINGLES OVER 30* PELT
2. 7/16" OSB ROOF DECK
3. 2 "x 6" ROOF RAFTERS @ 16" O.C.
4. ALUM. GUTTER
5. 5/4 "x 6" PRIELE W/ 4.25" CROWN
6. 1/2 DRYWALL
7. 2 "x 6 "_NAELER W/ 5/4 "x 6" GUTTER TRIM
8. 2 "x 4" SOFFIT FRAME
9. 2" CONT. SOFFIT VENT IN 1/4" CEDAR SOFFIT
10. INSULATION STOP / AIR SPACE
.11. 2 "x 4E" MIMS A 16" O.C.
12. 1/2" PLYWOOD SHEATHING
13. 2 "x 10" JOIST. (FINAL SIZING PER SUPPLIER)
.14. 2 1lx 4" PRES. 'TRTD.. TOP PL. W/ 1/2" ANCHOR
BOLTS 0 48" O.C.
15. BRICK VENEER W/ WEEP HOLES @ 48" O.C.
16. 3/4" OSB FLOOR DECK
17. 4" PERF. PVC. PERIMETER DRAINS, W/ GRAVEL BACKPILL
18. 8 "x 18" CONT. CONC. FIG. W/ 245 REBAR
19. 8 "' POURED CONC. BASEMT. WALL DESIGN SPECIFICATIONS
BY, SUBCONIRSACTOR. .
20. 4" CONC. SLAB W/ GRAVEL FILL OVER V. B.
21. R -13 BATT INSULATION
22. R -30 BLOWN INSULATION
23. 1.5" RIGID INSULATION BOARD W/ 2 "x 4" FUR STRIPS
0 24" O.C..(ALL FINISHED AREAS)
U. 2 "x 4" TRIM FRAMING
25. C ULING JOISTS
26. BRICK COURSE EXPRESSED 1/2"
.27. BRICK SOLDIER COURSE
28. WATERPROOFING/INSULATION SYSTEM
29. EXTRA TOP PLATE AT 12/12 SLOPE RAFTERS
NOTE: STEP ITEMS 18 AND 19 W/ GRADE. STUD KNEE WALL, AS
REQUIRED, FROM TOP OF WALL TO FLOOR BEARING.