Loading...
HomeMy WebLinkAbout12100043.13SELF - TAPPING SHEET METAL SCREWS AT 6" 1" MESH INSTALL FF.-1- - I . FILTER AT OPEN END OF RETURN DUCT rl_ REMOVABLE FRAME M2 SCALE: N.T.S. (RETURN DUCTS ONLY) SNAPLOCK SHEET METAL FLAT OVAL DUCT ­7 8" WIDE X Zu vhwc UML-VMI41, C-W o I U--cL PLATE SHIELD REQUIRED AT EACH HANGER, FULL WIDTH OF DUCT AND AT EACH POINT OF CONTACT WITH STRUCTURE ABOVE DUCT 20 GAUGE GALVANIZED SHEET METAL STRAPS ATTACHED TO STRUCTURE ABOVE 4TION TRANSVERSE DUCT JOINTS SHALL o� SEALED WITH DUCT SEALANT (SMACNA SEAL CLASS "C "). DUCT SEALANT SHALL BE OF THE SYNTHETIC ELASTOMERIC TYPE EQUAL TO "UNITED" "UNI- SEAL ". DUCT TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT 2 JINSULATED DUCT INSTALLATION M2 )SCALE: N.T.S. INSULATED (WHERE API 6" METAL STUDS SURFACE MOUI SUPPLY AIR GF 3 ISURFACE MOUNTED DIFFUSER M2 ) SCALE: N.T.S. LAMING SPACING i" O.C. 5/8" SHEETROCK (EACH SIDE) FURNISH ALL INTERNAL ROOF CURB FRAMING FOR DUCT SUPPORT IF NOT EXISTING OUTSIDE AIR INLET, SEE PLAN OR SCHEDULE FOR MINIMUM OUTSIDE AIR QUANTITY ---, ROOFTOP UNIT (RTU) SEE PLAN FOR LOCATION NATIONAL ACCOUNT ROOFTOP UNIT SCHEDULE 1.) ALL CARRIER HVAC UNITS WITH ACCESSORIES ARE OWNER SUPPLIED BY O'REILLY AUTOMOTIVE. MARK ACCOUNT MANAGER: 2.) MECHANICAL CONTRACTOR IS RESPONSIBLE FOR THE INSTALLATION OF ALL CARRIER HVAC UNITS. CAT. NO. LESLIE CASTERLINE 3.) MECHANICAL CONTRACTOR IS RESPONSIBLE FOR THE FIRST YEAR LABOR AND WARRANTY ON ALL OWNER CARRIER CORPORATION, 800 - 935 -5619 EXT. 3490 CUSTOMER SERVICE REPS: SUPPLIED EQUIPMENT. NATIONAL ACCOUNTS leslie .casterline@carrier.utc.com SARA TILTON 4.) MECHANICAL CONTRACTORS WORKING ON O'REILLY PROJECTS MUST CALL "CARRIER CORPORATION'S 29 INDUSTRIAL PARK DR. GENERAL MANAGER: 866 - 389 -4658 EXT. 3429 NATIONAL ACCOUNTS" DEPARTMENT FOR CONFIRMATION OF ORDERS AND BILL OF MATERIALS. BINGHAMTON, NY 13904 DOUGLAS MASCH sara.ti!ton @car(er.utc.com 5.) MECHANICAL CONTRACTOR IS RESPONSIBLE FOR SCHEDULING, SHIPPING & RECEIVING OF ALL OFFICE 317 - 240 -5265 CELL 317 - 370 -2727 CARRIER UNITS FROM CARRIER NATIONAL ACCOUNTS. CONTACT PERSON(S) LISTED TO THE RIGHT. MBH doug.masch @carder.utc.com DETAIL S1 SUPPLY DIFFUSER CATALOG HEATING MBH NOT USED GROSS CLG. MBH ARI SUPPLY FAN ANEMOSTAT ELECTRICAL Wt. 12x12 WHITE REF. MARK DESCRIPTION MFR. NUMBER %AFUE EER Ibs. ( ) ACCESSORIES REMARKS DETAIL IN OUT TOT. SENS. CFM O.A. ESP BHP V / PH MCA MOCP RTU -1 PACKAGED GAS R2 RETURN GRILLE ANEMOSTAT S3HD -81 PR, SPW, SS, HG, WHITE 4/M2 RTU, 2 ROOFTOP UNIT - CARRIER 48TCDD09 125 103 82 103.43 77.78 11 3400 340 0.70 1.63 208/3 40 50 1210 MSO, ECO, HP, TBC, TSI, DTS, UMD, 1,2,3,4,5,6 DT - DIRECTIONAL TABS. 8.5 TONS 2. UNLESS NOTED OTHERWISE - NECK SIZE OF DIFFUSER WILL MATCH DUCTWORK RUNOUTS TO THE DIFFUSERS. APPROVED ALTERNATE MANUFACTURER'S 3, 1 -WAY AIR FLOW GRILLES, DIFFUSERS, AND DAMPERS ZSM, SD 5/M2 PACKAGED HEATPUMP 4. 4 -WAY AIR FLOW • CARNES * PRICE INDUSTRIES * KRUEGER 5. PROVIDE 1" FIBERGLASS FILTER FOR GRILLE. PR, SPW, SS, HG, 4/M2 RTU -3 ROOFTOP UNIT - CARRIER 48TCEA06 115 93 81 61.03 45.01 13 2000 200 0.60 1.28 208/3 26.2 40 783 MSO, ECO, HP, TBC 1,2,3,4,5,6 5 TONS UMD, ZSM. , SD S 5/M2 ACCESSORIES - FACTORY SUPPLIED & FIELD INSTALLED REMARKS PR - POWER RECEPTACLE (FIELD POWERED), 15AMP, 120V, GROUND FAULT INTERRUPTER (GFI) TYPE. 1 • CAPACITY BASED ON 77.5 °F EDB AND 65.2° EWB, 91 °F AMBIENT. SPW - SINGLE POINT WIRING. SS - HI & LOW REFRIGERANT SAFETY SWITCHES. 2. NOTE! RTU COMPLETION. CONTRACTOR SHALL REMOVE ALL RETURN AIR FILTERS HG - LOUVERED HAIL GUARDS. FROM INSIDE ALL RTU's. CONTRACTOR SHALL INSTALL CLEAN FILTERS BEHIND MSO - MEDIUM STATIC FAN OPTION. EACH PLENUM /DIFFUER'S RETURN AIR GRILLE AND BEHIND EACH LAY -IN ECO - ENTHALPY ECONOMIZER WITH BAROMETRIC RELIEF. RETURN AIR FILTER GRILLE. HP - HINGED ACCESS PANELS. CONTRACTOR SHALL ALSO SUPPLY AN ADDITIONAL CLEAN SET OF FILTERS TO TBC - THRU- THE -BASE CONNECTIONS. THE OWNER AT JOB COMPLETION. MH - MEDIUM HEAT OPTION. 3• SEE PLAN FOR OUTSIDE AIR CALCULATIONS TABLE. 4. REFRIGERANT = R410A. 5• MAXIMUM CIRCUIT BREAKER OR TIME -DELAY FUSE. ACCESSORIES - O'REILLY SUPPLIED & FIELD INSTALLED TSI - THERMOSTAT: GRIDPOINT MODEL TS -300 COMMUNICATING THERMOSTAT W/ AUTO - CHANGEOVER, 2 -STAGE COOLING, 2 -STAGE HEATING, (NO SUBSTITUTIONS). 6. WEIGHT IS APPROXIMATE FROM AVAILABLE LITERATURE. VERIFY ACCURATE TOTAL DTS - DUCT TEMPERATURE SENSOR: GRIDPOINT MODEL DTS -1 TEMP.SENSOR, (NO SUBSTITUTIONS). WEIGHT, INCLUDING ALL ACCESSORIES AND OPTIONS, AND CONTACT PROFESSIONAL UMD - UNIT MOUNTED FUSED DISCONNECT: (GRAYBAR /O'REILLY) SUPPLIED W/ ELECTRICAL BILL OF MATERIALS. OF RECORD PRIOR TO INSTALLATION IF IT IS HEAVIER THAN ESTIMATED HERE. ZSM - ZONE SENSOR MODULE: GRIDPOINT MODEL #: ADM - ZSM -00 (NO SUBSTITUTIONS). SD - DUCT SMOKE DETECTOR: IN UNIT RETURN DROP - PROVIDE MODEL COMPATIBLE TO EMS EQUIPMENT BY GRIDPOINT. MODIFY /EXTEND EXISTING PIPING AS INTAKE AIR - NEOPRENE CONNECTORS REQURIED FOR FOR VIBRATION ISOLATION RECONNECTION TO NEW UNIT CAULK EXISTING ROOF STRAP tom•- 1" RIGID INSULATION BOARD FOR SOUND ISOLATION. SECURE TO INSIDE OF ROOF CURB IF NOT EXISTING. RETURN AIR INTAKE WITH FILTERS /RETURN AIR GRILLES WITH FILTERS SOFT PARTS HARD PARTS INSTALLATION I INSTALLATION 4 IROOFTOP UNIT (RETURN DU M2 ) SCALE: N.T.S. FURNISH ALL INTERNAL ROOF CURB FRAMING FOR - DUCT SUPPORT IF NOT EXISTING ROOFTOP UNIT (RTU) EXISTING ROOF SEE PLAN FOR LOCATION CURB- SEE KEYED NOTE #1 /M1 NEOPRENE CONNECTORS FOR VIBRATION ISOLATION - CAULK ................ ................ 1" RIGID INSULATION BOARD FOR SOUND ISOLATION. SECURE TO INSIDE OR ROOF CURB IF NOT EXISTING SUPPLY DUCT PER PLAN 5 ROOFTOP UNIT (SUPPLY DUCT M2 ) SCALE: N.T.S. OUTSIDE AIR INLET, SEE PLAN OR SCHEDULE FOR MINIMUM OUTSIDE AIR QUANTITY - INTAKE AIR EXISTING ROOF MEMBRANE MODIFY /EXTEND EXISTING PIPING AS REQUIRED FOR RECONNECTION TO NEW UNIT MOUNT SUPPLY GRILLE ON END OF DUCT. .:E TO ROUND ADAPTOR. GRILLE AND DIFFUSER SCHEDULE MARK DESCRIPTION MFR. CAT. NO. SIZE (IN.) FINISH MOUNTING MFG /MODEL ACCESSORIES REMARKS MCA ats ®aaetI ACCESSORIES Jeffrey License # DUCT SIZE MBH KW DETAIL S1 SUPPLY DIFFUSER VH -1 NOT USED 175 S2 SUPPLY DIFFUSER ANEMOSTAT 10.8 E -1 -D 12x12 WHITE SURFACE SEE PLAN DT 1, 2, 3 3 /M2 G1 SUPPLY GRILLE ANEMOSTAT ACCESSORY OPTIONS: 1. BUILT -IN THERMOSTAT (FACTORY INSTALLED) 3. RECESS MOUNTED S20H 14x8 WHITE DUCT SEE PLAN OB R1 RETURN GRILLE NOT USED -7 R2 RETURN GRILLE ANEMOSTAT S3HD -81 12x12 WHITE T SURFACE N/A _ 5 SIM (SIM. ) X1 EXHAUST GRILLE NOT USED ACCESSORIES REMARKS OB - OPPOSED BLADE DAMPER. 1. DIRECTIONAL TABS, ADJUST TO PROVIDE THROW AS INDICATED ON PLANS. DT - DIRECTIONAL TABS. 2. UNLESS NOTED OTHERWISE - NECK SIZE OF DIFFUSER WILL MATCH DUCTWORK RUNOUTS TO THE DIFFUSERS. APPROVED ALTERNATE MANUFACTURER'S 3, 1 -WAY AIR FLOW GRILLES, DIFFUSERS, AND DAMPERS • TITUS * TUTTLE AND BAILEY * NAILOR * ARROW 4. 4 -WAY AIR FLOW • CARNES * PRICE INDUSTRIES * KRUEGER 5. PROVIDE 1" FIBERGLASS FILTER FOR GRILLE. VESTIBULE HEATER SCHEDULE ®fie X BF OAS. •� HEATING CAPACITY TEMP. 0 c�j ELECTRICAL MARK MFG /MODEL CFM Cl- tLJ MCA ats ®aaetI ACCESSORIES Jeffrey License # MBH KW RISE VOLT/PH/HZ VH -1 MARKEL 175 7.7 2.3 57 °F 10.8 208V / 10 / 60 1, 2, 3 HF3385D -RP ACCESSORY OPTIONS: 1. BUILT -IN THERMOSTAT (FACTORY INSTALLED) 3. RECESS MOUNTED 2. DISCONNECT OWNER RE\ PERMIT /BID SHEETS BEARING THIS SE RESPONSIBILITY FOR ALL OR INSTRUMENTS ARE OK W ti (� O N O r- Z c c 00� U vi< O J CL W W F H H F cc IL O F a i' W cc b J �W W 32 d CC DRAWN: CHECKED: P DATE: C JOB NO.: SHEET: SHEET ®fie X BF OAS. •� N ®ev5TI 0 c�j 0 ., a o. P 1C d m Cl- tLJ Co ats ®aaetI Jeffrey License # Exp. Datl SHEETS BEARING THIS SE RESPONSIBILITY FOR ALL OR INSTRUMENTS ARE OK W ti (� O N O r- Z c c 00� U vi< O J CL W W F H H F cc IL O F a i' W cc b J �W W 32 d CC DRAWN: CHECKED: P DATE: C JOB NO.: SHEET: SHEET