HomeMy WebLinkAbout12100043.15NOTE: THE ILLUSTRATED MOUNTING HEIGHTS ARE TYPICAL SPECIAL HEIGHTS ARE NOTED AS FOLLOWS: a Tf 60" ABOVE COUNTER RECEPTACLE SWITCH RECEPTACLES COUNTER • DO co BOX W /RING COVER FOR SINGLE GANG FACE PLATE FOR >» TELEPHONE OR DATA OUTLET :USTOMER SIDE EMPLOYEE SIDE FLOOR BOX 4 -PLEX RECEPTACLE "*�VOICE/DATA CONDUITS STUBBED UP UNDER POWER CONDUITS COUNTER. UNDER COUNTER TYPICAL OUTLET MOUNTING HEIGHTS NOT TO SCALE FLOOR BOX SHALL BE LISTED SPECIFICALLY FOR "SURFACE MOUNTED FLOOR" INSTALLATION (RE: NEC 314.27(C)). DOUBLE GANG GALVANIZED STEEL SURFACE MOUNTED BOX WITH QUAD OUTLETS. PROVIDE WITH GALVANIZED STEEL FACE PLATE. 4 a DIMENSION LINE IS - TO CENTER OF BOX. SEE FLOOR PLAN. *'4 v v v 4 a v v 4 -PLEX OUTLET. SEE PLAN & 5 /E2 FOR TYPE REQUIRED v a 4 v a v v SURFACE MOUNTED FLOORBOX NOT TO SCALE DNTINUE THIS CONDUIT TEMPORARY DUCT 30VE CEILING TO THE TAPE TO CLOSE END ZONT COUNTER. SEE OF CONDUIT )WER PLAN. JUTE THIS CONDUIT 1" CONDUIT TO 30VE CEILING AND ABOVE CEILING )NTINUE TO PHONE )UIPMENT BOARD. 2" CONDUIT TO io ABOVE CEILING 4"DEEP 12 "X12" PULL BOX WITH SCREW COVER FOR DATA. WIRING TOP OF CONCRETE 0 CEILING STRUCTURE IN OFFICE. PUNCH 2" K0. IN TOP OF 4" DEEP 12 "X12" BOX. BY OTHERS. FACE BOXES TOWARDS OFFICE. TYPICAL THESE CONDUITS AND BOXES ARE A /OFFICE TO BE USED ONLY BY OWNERS 00 WALL VOICE AND DATA WIRING FLOOR SLAB a a a v v v ° a D d <' a CONDUIT ROUGH -IN AT OFFICE r NOT TO SCALE SHOWROOM COUNTERS AND PRINTER LOCATION KEYNOTES: (D2 -1" CONDUIT OVERHEAD (ONE ONLY VOICE AND DATA WIRING BY OWNER). 02 ALTERNATOR TESTER, 120V. INSTALL (2) TWO DUPLEX OUTLETS CIRCUITED WITH #10 WIRE. 02" CONDUIT FOR OWNER INSTALLED PHONE SERVICE TO COUNTER AND OFFICE. @ CONTRACTOR TO INSTALL "2600 WIREMOLD" RACEWAY ON FLOOR BETWEEN COUNTER AND PRINTER LOCATION. 50POWER POLE, EQUAL TO HUBBELL HBLPP, ALUMINUM WITH FINISH AS SELECTION BY ARCHITECT. BLANK POLE WITH BARRIER FOR POWER AN DATA CHANNELS. HEIGHT AS REQUIRED. @ QUADPLEX /FOURPLEX RECEPTACLE. SEE DETAIL 1/E3. OCONTRACTOR TO WIRE DEVICES FOR COUNTER WITH TYPE MC CABLE (ONLY) FROM TELE -POWER POLE. SEE DETAIL 1/E2. TYPICAL FOR ALL DEVICES AT COUNTER. @FLOOR BOX 4 -PLEX RECEPTACLE. SEE DETAIL 5/E2. @FLOOR BOX DUPLEX RECEPTACLE (FOR COKE MACHINE ONLY) SEE DETAIL 5/E2 SIM. AUXILIARY TRANSFORMER BOX -ADD GRID POINT PROVIDED MULTI - PURPOSE ENCLOSURE WITH DINRAILS 16 "X18 "X4" CLASS 2. HUB MODULE MAY BE MOUNTED INSIDE THE MPE, ALONG WITH TS300 THERMOSTATS (NO NEED SEPARATE ENCLOSURE). SEPARATE CLASS 1 CONTROL TRANSFORMER ENCLOSURE (CONTRACTOR PROVIDED) MUST REMAIN. ALL CLASS 1 & 2 ENCLOSURES MOUNTED ON WOOD BOARDS(S) MUST BE GROUNDED, AS PER NEC. HUB MODULE APPROXIMATELY 1' -0" ABOVE FINISHEDI FLOOR. �- FLOOR E.M.S. EQUIPMENT BOARD NOT TO SCALE OPEN 12 "x48" OPEN ALARM 8 "x96" PLACEMENT 16 "x24" PHONE SYSTEM PLACEMENT 24 "x48" TELCO EQUIPMENT PLACEMENT I CONTRACTOR TO MARK PHONE EQUIPMENT BOARD AS INDICATED FOR PLACEMENT OF EQUIPMENT AND INSTALL CONDUIT ONLY IN "OPEN" AREAS. OPEN 8"x96" LEAVE 1' -0" OF CLEARANCE IN FRONT OF TELEPHONE EQUIPMENT BOARD. SEE FLOOR PLAN. I I 'INSTALL 4'Wx8'Hx3 /4" APPROXIMATELY PLYWOOD AS SHOWN 1' -0" ABOVE FINISHED FLOOR. FLOOR TELEPHONE EQUIPMENT BOARD NOT TO SCALE CEILING MP -6 "PLP " -22 VIA EMERGENCY (1) 20A, 120V, /FLOOR TRACK. TYPICAL GENERATOR TRANSFER 4 -PLEX RECEPTACLE 8' COUNTER / 8' COUNTER SWITCH POSITION B —\ 8' COUNTER 6' COUNTER PLP -281 PLP -291 1- a I 1 PLP -16 20A, 120V, 4 -PLEX ISOLATED 20A, 120V, 4 -PLEX ISOLATED INSTALL FLOOR BOXES AT PULL HOMERUN GROUND RECEPTACLE INSIDE GROUND RECEPTACLE INSIDE THIS LOCATION BESIDE THROUGH POWER FLOOR BOX, TYPICAL OF THREE FLOOR BOX, TYPICAL OF THREE EACH OTHER / POLE TO ABOVE CEILING, OVER COUNTER MOUNTED RECEPTACLES PANEL. TYPICAL. . NOT TO SCALE E2 WIRING WHIP FROM CEILING: - AO WIRE TO INDICATED DEVICES WITH 20' OF WIRING "WHIP" OR TYPE MC CABLE. COIL AND "ZIP -TIE" WIRING "WHIP" TO PURLINS AT ROOF STRUCTURE. (FOR FUTURE DROP BY OWNER DOWN TO INDICATED EQUIPMENT.) WHERE A LOCATION HAS MULTIPLE DEVICES, LOCATE ALL DEVICES NEXT TO EACH OTHER AT ROOF STRUCTURE. P -20 O SHOW WINDOW RECEPTACLES MOUNTED NOT MORE THAN 18" ABOVE WINDOW, WHERE BOX CAN NOT BE RECESSED ABOVE WINDOW MOUNT IN CEILING TILE ADJACENT TO WALL. (TYPICAL OF 7) PLP -18 103 WP 60/3P W /40AF RTU -3 MP-32,34,36 MP-7 54' -3" PARTS AREA "W 100 TELEPHONE AND COMPUTER DATA SYSTEMS: A. ELECTRICAL CONTRACTOR SHALL PROVIDED AND INSTALL ALL TELEPHONE AND DATA CONDUITS. B. ELECTRICAL CONTRACTOR SHALL VACUUM OUT ALL CONDUITS TO REMOVE WATER. C. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL - STRING IN EACH CONDUIT. D. OWNER SHALL PROVIDE AND INSTALL ALL TELEPHONE AND DATA WIRING. A INSTALL JUNCTION BOXES FOR ENERGY MANAGEMENT SYSTEM DOOR POSITION SWITCHES, PER EQUIPMENT SUPPLIER REQUIREMENTS. TYP AT ALL EXTERIOR DOORS TWO AT DOUBLE DOORS. —� CONTRACTOR TO PROVIDE SIGN THAT GENERATOR OPERATION IS REQUIRED TO BE OUTSIDE OF BUILDING RELIANCE P630. WIRE TO GENERATOR TRANSFER SWITCH. SEE SHEET E3 ONE LINE DIAGRAM. PA\A ADMMICRO HJA DATE: MP -8,1 JOB NO.: 1204 EMS PLACEMENT LIGHTING CONTROL CONTROL PANEL. PANEL -1 PLACEMENT SEE SHEET ES2 GFI EMS TO BE INSTALLED MOUNT SCREEN AS CLOSE TO BREAKER APPROXIMATELY PANELS AS POSSIBLE. 5' -6" ABOVE 1' -6' x 8' -0" x 3/4" FINISHED FLOOR. 11PLP " -20 9 PLYWOOD BACK PANEL. R P -5 • 4' -0" CLEARANCE 60" REQUIRED IN FRONT OF BACK PANEL. APPROXIMATELY 1' -0" ABOVE FINISHEDI FLOOR. �- FLOOR E.M.S. EQUIPMENT BOARD NOT TO SCALE OPEN 12 "x48" OPEN ALARM 8 "x96" PLACEMENT 16 "x24" PHONE SYSTEM PLACEMENT 24 "x48" TELCO EQUIPMENT PLACEMENT I CONTRACTOR TO MARK PHONE EQUIPMENT BOARD AS INDICATED FOR PLACEMENT OF EQUIPMENT AND INSTALL CONDUIT ONLY IN "OPEN" AREAS. OPEN 8"x96" LEAVE 1' -0" OF CLEARANCE IN FRONT OF TELEPHONE EQUIPMENT BOARD. SEE FLOOR PLAN. I I 'INSTALL 4'Wx8'Hx3 /4" APPROXIMATELY PLYWOOD AS SHOWN 1' -0" ABOVE FINISHED FLOOR. FLOOR TELEPHONE EQUIPMENT BOARD NOT TO SCALE CEILING MP -6 "PLP " -22 VIA EMERGENCY (1) 20A, 120V, /FLOOR TRACK. TYPICAL GENERATOR TRANSFER 4 -PLEX RECEPTACLE 8' COUNTER / 8' COUNTER SWITCH POSITION B —\ 8' COUNTER 6' COUNTER PLP -281 PLP -291 1- a I 1 PLP -16 20A, 120V, 4 -PLEX ISOLATED 20A, 120V, 4 -PLEX ISOLATED INSTALL FLOOR BOXES AT PULL HOMERUN GROUND RECEPTACLE INSIDE GROUND RECEPTACLE INSIDE THIS LOCATION BESIDE THROUGH POWER FLOOR BOX, TYPICAL OF THREE FLOOR BOX, TYPICAL OF THREE EACH OTHER / POLE TO ABOVE CEILING, OVER COUNTER MOUNTED RECEPTACLES PANEL. TYPICAL. . NOT TO SCALE E2 WIRING WHIP FROM CEILING: - AO WIRE TO INDICATED DEVICES WITH 20' OF WIRING "WHIP" OR TYPE MC CABLE. COIL AND "ZIP -TIE" WIRING "WHIP" TO PURLINS AT ROOF STRUCTURE. (FOR FUTURE DROP BY OWNER DOWN TO INDICATED EQUIPMENT.) WHERE A LOCATION HAS MULTIPLE DEVICES, LOCATE ALL DEVICES NEXT TO EACH OTHER AT ROOF STRUCTURE. P -20 O SHOW WINDOW RECEPTACLES MOUNTED NOT MORE THAN 18" ABOVE WINDOW, WHERE BOX CAN NOT BE RECESSED ABOVE WINDOW MOUNT IN CEILING TILE ADJACENT TO WALL. (TYPICAL OF 7) PLP -18 103 WP 60/3P W /40AF RTU -3 MP-32,34,36 MP-7 54' -3" PARTS AREA "W 100 TELEPHONE AND COMPUTER DATA SYSTEMS: A. ELECTRICAL CONTRACTOR SHALL PROVIDED AND INSTALL ALL TELEPHONE AND DATA CONDUITS. B. ELECTRICAL CONTRACTOR SHALL VACUUM OUT ALL CONDUITS TO REMOVE WATER. C. ELECTRICAL CONTRACTOR SHALL PROVIDE PULL - STRING IN EACH CONDUIT. D. OWNER SHALL PROVIDE AND INSTALL ALL TELEPHONE AND DATA WIRING. A INSTALL JUNCTION BOXES FOR ENERGY MANAGEMENT SYSTEM DOOR POSITION SWITCHES, PER EQUIPMENT SUPPLIER REQUIREMENTS. TYP AT ALL EXTERIOR DOORS TWO AT DOUBLE DOORS. —� CONTRACTOR TO PROVIDE SIGN THAT GENERATOR OPERATION IS REQUIRED TO BE OUTSIDE OF BUILDING RELIANCE P630. WIRE TO GENERATOR TRANSFER SWITCH. SEE SHEET E3 ONE LINE DIAGRAM. -- _j-- - _j- - -_j 60" II @ 1 4 I1 0 MP -4 O I I I I •_ PLP -' 27 ROUTE TO 1204 I CONTROL PANEL. —P LP-8 VIA EMERGENCY SEE SHEET ES2 4 G6ERATOR TRANSFER MP -1 ° SWITCH POSITION A MP -12 �L� o I 60" MP -3 THRU EMS VH -1 7 - -- LIGHTING CONTROLLER MP -9,11 8 6 4 I „ MP -14 RELAY #5, TERMINAL 1 - - -- PL -12 - -- I MP -1 PLP -18 0„ 9 I CM o ( - -- ilia MP -22 ' ALL DEVICES IN THIS '- 14 FIXTURE IS MOUNTED 60" 4 "x4" BOXES SHALL BE HUNG 0 60" A.F.F. TO BOTTOM OF BOX. CONDUIT SHALL EXTEND MAX. OF 5' ABOVE BOX. MOUNT RECEPTACLE IN CEILING FOR "OPEN" SIGN. CIRCUIT RECEPTACLE TO NEAREST LIGHTING CONTROL PANEL CONTROLLED LIGHTING CIRCUIT. "OPEN" SIGN WILL BE OPERATED BY INTEGRAL PULL CHAIN. SCALE. 118" =1' -O" -TELEPHONE EQUIPMENT LOCATION. INSTALL g 4'WX8'HX -'4" PLYWOOD 1' -0" A.F.F. GENERATOR TRANSFER SWITCH, 6 /E3. PANEL MP (LP1) PANEL PLP (RP1) ENERGY MANAGEMENT SYSTEM r LOCATION. "MP "- 38,40,42 E2 INSTALL GENERATOR CORD BOX. HOFFMAN #ASE12X12X4 BOX WITH SCREW COVER.(NEMA 1 ENCLOSURE.) PROVIDE LABEL FOR GENERATOR CORD STORAGE ONLY. \ EXISTING WATER HEATER PLP -24. VERIFY EXACT LOCATION 1 ko _ ON � LATHE, 120V INSTALL RECEPTACLES SHOWN AND CIRCUIT WITH #10 WIRE — INSTALL JUNCTION BOXES FOR ENERGY MANAGEMENT SYSTEM DOOR POSITION SWITCHES, PER EQUIPMENT SUPPLIER REQUIREMENTS. TYP AT ALL EXTERIOR DOORS TWO AT DOUBLE DOORS. CUTOFF SAW 120V INSTALL RECEPTACLES SHOWN & CIRCUIT W/ #10 WIRE - CRIMPER 120V, W/ 1 HP MOTOR. INSTALL W/ #10 WIRE. e07II7TRIBUTI OWNER REVIEV PERMIT /BID A A� i • •c110" 'EO I O?,1A0 a HA900MM 1 :.... -- y Ae SHEETS BEARING THIS SEAL AR RESPONSIBILITY FOR ALL OTHEf OR INSTRUMENTS ARE DISCLAIN W O x UJI -0 O (� ON� r Q 0f O N O j I— oc� cn Uti_ m C O CL r -U)11 O CQ U) FM cc W F no H cc o ox F 4 W c .� c c W O a cc C C O o L -3 04 (n i M ! cy) N DRAWN: PA\A CHECKED: HJA DATE: MP -8,1 JOB NO.: 3123 ROUTE TO 1204 CONTROL PANEL. A SEE SHEET ES2 GFI 11PLP " -20 9 3 - -- R P -5 • 60" G 1 I DEDICATED CIRCUIT FOR FUTURE USE.- - -J EWC WP 60 P / 3 E2 (LOCATE DUPLEX OUTLET 9' -6" AFF TO - --- MP -16 BOTTOM WITHIN HUBBELL DEEP SINGLE -�- I W /50AF 5 GANG HINGED COVER #RW57350). ___� -- " PLP -10 VIA EMERGENCY MP- 7 RTU -2 r GENERATOR TRANSFER - -- SWITCH POSITION E --T - -- P GFI WP/7 / MP- 25,27,29 — MP -7 PARTS AREA 1 6 I _ WP /GFI II - -- WP 60/31P --- IJ-- -J - - -� RTU -1 W /50AF - 2�9S.4QT - - -, 34' -4" o I 7 T-- -T - - -, 77 —26 VII ___J---J___J I 4 it LmLRGENCY GENERATOR TR NSFER PLP - 60" -- _j-- - _j- - -_j 60" II @ 1 4 I1 0 MP -4 O I I I I •_ PLP -' 27 ROUTE TO 1204 I CONTROL PANEL. —P LP-8 VIA EMERGENCY SEE SHEET ES2 4 G6ERATOR TRANSFER MP -1 ° SWITCH POSITION A MP -12 �L� o I 60" MP -3 THRU EMS VH -1 7 - -- LIGHTING CONTROLLER MP -9,11 8 6 4 I „ MP -14 RELAY #5, TERMINAL 1 - - -- PL -12 - -- I MP -1 PLP -18 0„ 9 I CM o ( - -- ilia MP -22 ' ALL DEVICES IN THIS '- 14 FIXTURE IS MOUNTED 60" 4 "x4" BOXES SHALL BE HUNG 0 60" A.F.F. TO BOTTOM OF BOX. CONDUIT SHALL EXTEND MAX. OF 5' ABOVE BOX. MOUNT RECEPTACLE IN CEILING FOR "OPEN" SIGN. CIRCUIT RECEPTACLE TO NEAREST LIGHTING CONTROL PANEL CONTROLLED LIGHTING CIRCUIT. "OPEN" SIGN WILL BE OPERATED BY INTEGRAL PULL CHAIN. SCALE. 118" =1' -O" -TELEPHONE EQUIPMENT LOCATION. INSTALL g 4'WX8'HX -'4" PLYWOOD 1' -0" A.F.F. GENERATOR TRANSFER SWITCH, 6 /E3. PANEL MP (LP1) PANEL PLP (RP1) ENERGY MANAGEMENT SYSTEM r LOCATION. "MP "- 38,40,42 E2 INSTALL GENERATOR CORD BOX. HOFFMAN #ASE12X12X4 BOX WITH SCREW COVER.(NEMA 1 ENCLOSURE.) PROVIDE LABEL FOR GENERATOR CORD STORAGE ONLY. \ EXISTING WATER HEATER PLP -24. VERIFY EXACT LOCATION 1 ko _ ON � LATHE, 120V INSTALL RECEPTACLES SHOWN AND CIRCUIT WITH #10 WIRE — INSTALL JUNCTION BOXES FOR ENERGY MANAGEMENT SYSTEM DOOR POSITION SWITCHES, PER EQUIPMENT SUPPLIER REQUIREMENTS. TYP AT ALL EXTERIOR DOORS TWO AT DOUBLE DOORS. CUTOFF SAW 120V INSTALL RECEPTACLES SHOWN & CIRCUIT W/ #10 WIRE - CRIMPER 120V, W/ 1 HP MOTOR. INSTALL W/ #10 WIRE. e07II7TRIBUTI OWNER REVIEV PERMIT /BID A A� i • •c110" 'EO I O?,1A0 a HA900MM 1 :.... -- y Ae SHEETS BEARING THIS SEAL AR RESPONSIBILITY FOR ALL OTHEf OR INSTRUMENTS ARE DISCLAIN W O x UJI -0 O (� ON� r Q 0f O N O j I— oc� cn Uti_ m C O CL r -U)11 O CQ U) FM cc W F no H cc o ox F 4 W c .� c c W O a cc C C O o L -3 04 (n i M ! cy) N DRAWN: PA\A CHECKED: HJA DATE: 0$/3' JOB NO.: 3123 SHEET: Eldif � SHEET 2 OI