HomeMy WebLinkAbout12100043.19GRIDPOINT ENERGY MANAGEMENT SYSTEM NOTES: GRIDPOINT HAS BEEN SELECTED TO BE THE ENERGY MANAGEMENT SYSTEM (EMS) SUPPLIER FOR ALL O'REILLY AUTO PARTS NEW CONSTRUCTION, AND RETROFIT SITES. IT IS THE GENERAL CONTRACTOR'S RESPONSIBILITY TO INSURE THAT THE ENERGY MANAGEMENT SYSTEM IS CORRECTLY INSTALLED WITHIN ALL O'REILLY AUTO PARTS NEW STORE CONSTRUCTION SITES. THE INFORMATION ON THE EMS SUPPLIED IN THESE NOTES AND DRAWINGS IS INTENDED TO BE A GENERIC GUIDELINE. SITE SPECIFIC CONFIGURATIONS SHALL BE THE RESPONSIBILITY OF THE PRIMARY ENGINEERING FIRM, AND O'REILLY'S CONSTRUCTION DESIGN DIVISION. THE GENERAL INTENT OF THESE NOTES AND DRAWINGS IS TO PROVIDE GUIDANCE TO THE INSTALLING CONTRACTOR, HAVING OVERALL KNOWLEDGE OF ENERGY MANAGEMENT SYSTEMS, HVAC, AND ELECTRICAL CONSTRUCTION. GRIDPOINT RESPONSIBILITIES: GRIDPOINT IS RESPONSIBLE FOR SUPPLYING TO O'REILLY AUTO PARTS, AT NO COST TO THE INSTALLING CONTRACTOR, THE FOLLOWING COMPONENTS OF THE EMS: • ADM -1204 ENERGY MANAGEMENT CONTROLLER • ADM -LCP - LOAD CONTROL PANEL WITH PHOTO -DIODE • ADM -TS300 COMMUNICATING THERMOSTATS (1 PER HVAC UNIT) • ADM -MPE - MULTI PURPOSE ENCLOSURE (1 PER 6 TS300s) • 1 TWO WIRE HUB MODULE • 20 AMP CURRENT TRANSFORMERS (1 PER INDIVIDUAL SIGNAGE LOAD) • 150 AMP CURRENT TRANSFORMERS (1 PER HVAC UNIT; 1 PER RESISTIVE HEATING LOAD) • 400/600/1000 AMP CURRENT TRANSFORMERS (AS NEEDED FOR MAIN SERVICE) • 120 /24VAC -60HZ AUXILIARY CONTROL TRANSFORMER (AS REQUIRED) • DUCT PROBE SENSOR (1 PER HVAC UNIT, 1 FOR OUTSIDE AIR TEMPERATURE) • ADM -ZSM - ZONE SENSOR MODULE (1 PER RTU /CONDENSER/HVAC UNIT) • 1 - 25' RJ -11 - 4 CONDUCTOR PHONE CABLE • 1 - 7' RI-45 - 8 CONDUCTOR CAT -5E LAN CABLE • MAGNETIC DOOR CONTACT SWITCH (2 PER SITE) • CONVENTIONAL THERMOSTAT INTERFACE CARDS (ONLY FOR CERTAIN TRANE HVAC UNITS) NOTE: MULTI ZONE TEMPERATURE AVERAGING IS SUPPORTED AND AVAILABLE. IF THIS FUNCTIONALITY IS NEEDED FOR SPECIAL APPLICATIONS, CONSULT PROJECT ENGINEERING PRIOR TO KIT PREPARATION. GRIDPOINT ENERGY MANAGEMENT SYSTEM NOTES: GRIDPOINT SHALL PROVIDE TECHNICAL SUPPORT DURING NORMAL BUSINESS UNLESS CODE REQUIREMENTS DICTATE THAT THE CLASS 2 CABLE BE EMPLOYEE LIGHTING: HOURS TO ASSIST INSTALLERS WITH TROUBLESHOOTING AND COMMISSIONING ROUTED THROUGH CONDUIT, CONDUIT SLEEVES WILL BE INSTALLED UP THE EMS SYSTEM. TECHNICAL SUPPORT IS AVAILABLE BY CALLING (866) INTO THE BAR JOISTS, OR ABOVE THE CEILING TILES. CLASS 2 CABLES SHALL NOT INHABIT CONDUITS /WIREWAYS WITH POWER CONDUCTORS. EMT CONNECTORS AND BUSHINGS WILL BE INSTALLED TO PROTECT THE CABLING FROM CHAFFING AND ABRASION. CIRCUIT BREAKERS: THE GENERAL CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE INSTALLATION OF DEDICATED BREAKERS TO SUPPLY POWER TO ALL COMPONENTS OF THE EMS. THESE BREAKERS MAY INCLUDE, BUT WILL NOT BE LIMITED TO: • ONE - SINGLE POLE - 20 AMP /120V FEEDER FOR AUXILIARY CONTROL TRANSFORMER(S): LABELED "EMS AUX POWER" • ONE - SINGLE POLE - 20 AMP /120V FEEDER FOR LOAD CONTROL PANEL: LABELED "EMS LCP POWER" • ONE - TWO (OR THREE) POLE - 20 AMP BREAKER, AT SERVICE ENTRANCE VOLTAGE, TO PROVIDE PRIMARY METERING VOLTAGE TO THE 1204: LABELED "EMS METERING VOLTAGE" • THE NUMBER OF POLES SHALL BE PREDICATED ON STORES MAIN • SERVICE CONFIGURATION. • ONE - SINGLE POLE - 20 AMP /120V OR 240V FEEDER FOR ADM -1204 INPUT POWER (IF PRIMARY METERING VOLTAGE IS 480V): LABELED "EMS INPUT POWER" CURRENT TRANSFORMERS: ALL CURRENT TRANSFORMERS MUST BE INSTALLED AS DEPICTED IN THE ATTACHED SHEETS. THE HVAC CT'S MUST BE INSTALLED ON PHASE "A." WHERE MORE THAN 12 CTs ARE REQUIRED, CONTACT PROJECT ENGINEER. INTERIOR LIGHTING: AS DEPICTED IN THE ATTACHED SHEETS, THERE WILL BE AT LEAST THREE INTERIOR LIGHTING ZONES. SECURITY LIGHTING, EXIT LIGHTING AND EMERGENCY LIGHTING WILL BE ENERGIZED 24 HOURS. THE SECURITY LIGHTING WILL INCLUDE A LIGHT INSTALLED ON THE EXTERIOR OF THE BUILDING ABOVE THE DELIVERY DOOR. DOOR SWITCH DETAIL SWITCH /MAGNETIC PICKUP O O O O RARE EARTH MAGNET N.T.S. NOTE, UTILIZE THE N.O. (NORMALLY OPEN) CONTACT ❑PTI ❑N. THE MAXIMUM OPERABLE GAP BETWEEN MAGNET AND PICKUP = 2JV2' EMPLOYEE LIGHTING WILL CONSIST OF APPROXIMATELY 50% OF THE INTERIOR LIGHTING CIRCUITS. THESE CIRCUITS HAVE BEEN DESIGNED TO PROVIDE SUFFICIENT LIGHTING FOR STORE OPENING, CLOSING AND CLEANING OPERATIONS. THESE LIGHTS WILL BE CONTROLLED BY THE EMS THROUGH THE LCP AND WILL BE ENERGIZED IN ACCORDANCE WITH THE STORE'S OPERATING SCHEDULE. NOTE THAT THE LCP IS SUPPLIED WITH NORMALLY CLOSED CONTACTS. WHEN THE POWER SUPPLYING THE LCP CONTROL BOARD IS INTERRUPTED, THE CONTACTORS CLOSE AND ALL THE INTERIOR, EXTERIOR LIGHTING AND SIGNAGE LOADS ARE ENERGIZED. SALES LIGHTING: SALES LIGHTING WILL CONSIST OF THE BALANCE OF THE INTERIOR LIGHTING CIRCUITS. THESE CIRCUITS WILL BE ENERGIZED WHEN THE STORE OPENS TO THE PUBLIC AND WILL BE EXTINGUISHED WHEN THE STORE CLOSES. EXTERIOR LIGHTING: THE PARKING LOT, WALL PACKS AND SOFFITT LIGHTING WILL BE CONTROLLED BY THE EMS THROUGH THE LCP. THESE LIGHTS WILL BE OPERATED BASED ON LOCAL SUNRISE AND SUNSET TIMES AND ON THE STORE SCHEDULE. SIGNAGE SYSTEMS: ALL POLE AND BUILDING MOUNTED SIGNAGE SYSTEMS WILL BE CONTROLLED BY THE EMS THROUGH THE LCP AND A CONTRACTOR. THESE SIGNS WILL BE OPERATED BASED ON AMBIENT LIGHT LEVELS, LOCAL SUNRISE AND SUNSET TIMES, AND ON THE STORE SCHEDULE. PHOTO -DIODE AND OUTSIDE AIR TEMPERATURE SENSOR INSTALLATION THE GENERAL CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF THE PHOTODIODE AND OUTSIDE AIR TEMPERATURE SENSOR. THE PHOTODIODE AND SENSOR ASSEMBLY MUST BE MOUNTED FACING NORTH. SEE SUGGESTED ASSEMBLY DRAWING ON SHEET ES -3 (BELOW). CONTINUE TO TS300 ENCLOSURE. VERTICAL CONDUIT RISER TO ROOF TRUSS ONLY PHOTO OF BEST ROLLING DOOR INSTALL METHOD, LEFT HAND DEPICTED, EITHER SIDE IS ACCEPTABLE, AS SITE DESIGN DICTATES RARE EARTH `MAGNET LOCATIONS ON DOOR FRAME. SHIELDED /TWISTED PAIR TO TS300 THERMOSTAT (T4 INPUT —SEE ES2 SHEET) CONTROLLING HVAC UNIT SERVING RECEIVING AREA. RIGHT HAND DEPICTED FOR EFFICIENT CONDUIT APPLICATION _ATION JUNCTION EMT CONDUIT, 800 -8906. THE FOLLOWING MUST BE COMPLETED BEFORE CALLING FOR COMMISSIONING SUPPORT: • SYSTEM MUST BE COMPLETELY INSTALLED AND READY TO BE PLACED UNDER POWER • ALL COMPONENTS MUST BE MOUNTED AND WIRED • ALL DATA WIRING MUST BE PULLED AND LANDED • ENSURE THAT CAT -5E HUB MODULE TERMINATIONS WERE NOT STRIPPED PRIOR TO INSERTION INTO PUSH DOWN TERMINALS • ENSURE THAT ZONE SENSOR MODULES ARE INSTALLED AS DENOTED ON M1 MECHANICAL SHEET, AND WIRED AS DENOTED ON ES2 WIRING DIAGRAM • ENSURE THAT DOOR CONTACT SWITCHES HAVE BEEN INSTALLED ON REAR ROLL -UP AND MAN DOORS, BEING TERMINATED AT THE TS300 THERMOSTAT CONTROLLING NEAREST HVAC UNIT TO DOORS • THE LIGHTING AND SIGNAGE CIRCUITS MUST BE ROUTED THROUGH THE LCP, WITH LOADS AVAILABLE FOR TESTING • ALL THE EXTERIOR LIGHTING AND SIGN CONTACTORS MUST BE WIRED • THE PHOTO -DIODE MUST BE INSTALLED AND PROPERLY ORIENTATED FACING NORTH • ENSURE THAT ALL CURRENT TRANSFORMERS HAVE BEEN INSTALLED WITH THE CT LABEL FACING THE SOURCE, UPON THEIR CALLED FOR CIRCUITS • THE HVAC SYSTEM MUST BE INSTALLED AND OPERATIONAL, AS CONDENSER AND HEATING TEST RUNS SHALL BE REQUIRED • THE SYSTEM MUST BE CONNECTED TO AN ACTIVE TELEPHONE LINE WITH A DIAL TONE TO ALLOW REMOTE ACCESS AND PROGRAM DOWNLOADS • PRIMARY LAN CONNECTIVITY MUST BE ESTABLISHED AND OPERABLE INSTALLATION: THE GENERAL CONTRACTOR IS RESPONSIBLE FOR VERIFYING THAT THE INSTALLATION COMPLIES WITH ALL FEDERAL, STATE AND LOCAL BUILDING CODES AND WITH ALL APPLICABLE SECTIONS OF THE NATIONAL ELECTRICAL CODE. THE GENERAL CONTRACTOR IS ALSO RESPONSIBLE FOR COORDINATING THE INSTALLATION OF THE SYSTEM BETWEEN TRADES AND SUBCONTRACTORS. NORMALLY, THE HVAC, TELEPHONE, AND ELECTRICAL TRADES WILL BE REQUIRED TO INSTALL THE SYSTEM AND PLACE IT INTO OPERATION. IT IS HIGHLY RECOMMENDED THAT CONTROL AND POWER WIRING BE COMPLETED BY LICENSED ELECTRICAL CONTRACTORS. NOTE: 1. ASSEMBLY DETAIL IS INTENDED TO PROVIDE GUIDANCE TO INSTALLERS FOR TYPICAL FIELD ASSEMBLY AND INSTALLATION 2. PHOTO —DIODE SHOULD BE FACING NORTH ASSEMBLY SHOULD BE MOUNTED 10' -0" AWAY FROM THE EXHAUST DUCTING FROM FANS & HVAC SYSTEMS TO PERMIT ACCURATE AIR TEMPERATURE SENSING 3. ASSEMBLY MUST BE MOUNTED AT A HEIGHT ABOVE THE ROOF DECK TO INSURE THAT THE SENSORS ARE NOT AFFECTED BY SNOWLOADS. 4. DO NOT PAINT ASSEMBLY. 5. PHOTO —DIODE WIRING TO LCP TO BE 18AWG STRANDED TWISTED PAIR. 6. OUTSIDE AIR TEMPERATURE WIRING TO TS300 THERMOSTAT TO BE 18AWG STRANDED TWISTED PAIR. 7¢" EMT CONDUIT RUN TO EMS SINGLE GANG WATERPROOF OUTLET BOX BY CONTRACTOR 2 #18 AWG TO LCP CONTROL BOARD QUESTIONS CONCERNING EQUIPMENT ORDERS, INSTALLATION ISSUES, OR GENERAL TECHNICAL ISSUES MAY BE ADDRESSED TO: WHEN READY TO COMMISSION, CALL THE HELPDESK NUMBER: (866) 800 -8906 AND SELECT THE COMMISSIONING OPTION. POST COMMISSION TECHNICAL ISSUES OR QUESTIONS SHOULD ALSO BE ADDRESSED TO THE ABOVE HELPDESK NUMBER. • OUTDOOR PHOTO —DIODE WALL MOUNTED • FACING NORTH ALTERNATE COVER PLATE WITH 1i" KO USE TYPE B CONNECTOR FOR DAMP LOCATIONS OUTDOOR PHOTO -DIODE ONLY N.T.S. GRIDPOINT, Inc- PAW PA # 121 - 0002 —zz PHOTO —DIODE ASSEMBLY LOW PROFILE STRAIN RELIEF CORD CONNECTOR UPC /DCl/NAED TRADE CORD R Z ME 901 8897 ME .100/.; GRIDPOINT, Inc. PART # 121- 0001 —ZZ 3.25" TEMPERATURE PROBE NORTH BUILDING WALL WALL MOUNTED • D••- - Al • 01 •C =W-IM611111JUK - 0 DRILL .060 WEEP HOLE • • • • 0 • • • a. b. C. d. e. f. Minimum EMS Cabling Requirements: Primary Voltage Metering — #12 AWG THHN /THWN Controller Input Power — #12 AWG THHN /THWN 120/24VAC Control Transformer Primary — #14 AWG THHN /THWN 120/24VAC Control Transformer Secondary — #18 AWG Solid or Stranded 12VDC Power Supply — 120VAC Primary — #14 AWG THHN /THWN 12VDC Power Supply — 12VDC Secondary Output — #18 AWG Solid or Stranded Rope CT Amplifier Supply — #14 AWG THHN /THWN CT Extensions — CAT -5E (6 twist per foot minimum) See NEC for Riser /Plenum rating requirements — Wire nuts are not an acceptable means of CAT -5E junction. Utilize proper terminals or splices Thermostat Communication Chains and LCP Communication Loop— CAT -5E Outboard Sensors — #18 -24 AWG stranded /twisted /shielded pair (Belden 8451, 9451, or equivalent) Shields /Drains are to be terminated on the respective equipment ground terminals of the home thermostats /controller enclosures (home end only). Separate and insulate remote end shields. Zone Sensor Modules Duct Probe Sensors Outside Air Temperature Sensors Photo Diodes Pulsed Metering Inputs Digital Inputs /Outputs DISTRIE OWNER RE ® PERMIT /BIC Professior SHEETS BEARING THIS S RESPONSIBILITY FOR AL OR INSTRUMENTS ARE 0 N F a am 0 a Uc w� 0 Ws oC DRAWN: CHECKED: DATE: JOB NO.: SHEET: SHEET