Loading...
HomeMy WebLinkAbout12100043.4EX'G 18 S41 5 V -8" ol 1 EX'G1 11 A3 EXISTING A3 PROPOSED 9 9 � X W A O A3 A3 _ MEN'S PROPOSED EXISTING 8 TOILET RM. - - -- -- -- - -- - 104 2 T ELECTRICAL UU 0 u� / �� 2 13 106 PARTS AREA "C" CO 1 12 M! 5 '103 `" ! � WOMEN'S w • TOILET RM. 17 17 m 1� (19;: . 105 cn 4'A � co A4 O 16 "' 3 ! A3 1 ` 0 EXISTING v ' ABOVE N 18 43' -2 1/8" 1 16-9 7/8" 1 37' -4 318" A3 ao 7 3 5/8" r` PROPOSED 17 iI 60' -0" '-n I I S44 O (ABOVE) z S46 CO — — — — — — — °�, — w I S44 6 M (ABOVE) 6 S 4 6 `O ao EX'G `O PARTS AREA "A" 17 100 1 o 17 I I S44 PARTS AREA - 1 (ABOVE) " B" 101 S46 S44 c°n (ABOVE) 10 S46 11 S44 23 t7 O ! D o (ABOVE) A4 'n': 17 °' 16 T -6" w 4 0 4 ;r 14 A1.1 S42 \4 5 9 iv 1B ABOVE N OFFICE - 5 A1.1 11 10 5 C' 7 20 I ' a0 C' 102 S43 A1.1 A1.1 9 1k 1 11 1 w Co j< 14 I ' W 9' -0" W 11 u1 9 9 9 9 9 9 9 10 10 ;10 i B9 9- 9 9 9 9 10 11 <1 (,11) � i C11 11 11 11 ..... ... _....... ..._ 15' -7" EXISTING 15' -6 3/4" EXISTING 16' -7 1/4" EXISTING 100' -0" EXISTING 3 1 A3 A3 PROE599 EXISTING 5/8" TYPE 'X' GWB ON (1) SIDE TO 11' -6" A.F.F. i (25 GA.) MTL. STUDS AT 24" O.C. TO 11' -6" A.F.F. S41 S42 I <o Q S46 1 WALL TYPES A1.1 SCALE: 1 1/2" = V -0" 6 FLOOR PLAN A1.1 SCALE: 1/8" = V -0" N 5/8" TYPE 'X' GWB EACH SIDE TO 11' -6" A.F.F. 3 -5/8" (20 GA.) MTL. STUDS AT 24" O.C. TO 11' -6" A.F.F. REFER TO SHEET A1.3 FOR MORE INFO 5/8" TYPE 'X' GWB EACH SIDE TO 11' -6" A.F.F. 3/4" LATTICE TRIM PEGBOARD OVER 1/2" WD. BLOCKING @ 16" O.C. 3 -5/8" (20 GA.) MTL. STUDS AT 24" O.C. TO 11' -6" A.F.F. REFER TO SHEET A1.3 FOR MORE INFO 5/8" TYPE 'X' GWB EACH SIDE 3 -5/8" (20 GA.) MTL. STUDS AT 24" O.C. TO 8' -6" A.F.F. 3 1/2" U N FAC ED BAIT. SOUND INSULATION 5/8" TYPE 'X' GWB EACH SIDE TO 11' -6" A.F.F. 3 -5/8" (20 GA.) MTL. STUDS AT 24" O.C. TO 11' -6" A.F.F. REFER TO SHEET A1.3 FOR MORE INFO S43 S44 NOTES: 1- REFER TO SHEET Al .3 FOR TYPICAL SECURING OF BASE OF NEW WALL CONSTRUCTION. 2. REFER TO 10/A1.2 FOR TYPICAL HEADER & JAMB STUD CONSTRUCTION AT NEW INTERIOR WALLS. 3. PROVIDE FIRE STOPPING AND FIRE SEALANT MATERIALS AS REQUIRED AT ALL RATED WALL CONSTRUCTION MATERIAL TRANSITIONS AND PENETRATIONS. RATING TO BE EQUAL TO RATED WALL ASSEMBLY. 4. PROVIDE DIAGONAL BACKING BRACING (3" X 16 GA. FLAT STRIP) AT CORNER FACES OF FREE STANDING PARTITION SYSTEMS. 5. PROVIDE MOISTURE RESISTANT TYPE 'X' GYPSUM BOARD IN TOILET ROOMS, BEHIND MOP SINK AND BEHIND DRINKING FOUNTAIN. 6. PROVIDE 'J' MOLDING REGLETS OR CORNER BEAD AT ALL DISSIMILAR WALL MATERIAL TRANSITIONS. 7. INSULATION SHALL HAVE A FLAME SPREAD RATING OF 0 -25 AND A SMOKE DEVELOPMENT RATING OF 0-450. EX'G1 3E 5/8" GWB EXISTING WALL 4" VINYL BASE FINISH FLOOR DBL_ 3 5/8" (20 GA.) MTL. STUDS @ C.J. AS SH „T ,. , ..6" (1) PIECE VEE- SHAPED SLOT CONTROL JOINT @ BOTH SIDES OF HEADER GWB 4 CONTROL JOINT A1.1 SCALE: 1 1/2" = V -0" GENERAL NOTES: A. ALL DIMENSIONS TO ROUGH FACE OF ROUGH FRAMING, CONCRETE OR CENTERLINE OF STRUCTURE, UNLESS OTHERWISE NOTED. B. REFER TO SHEET F1 FOR INTERIOR FINISH REQUIREMENTS AND OWNER FURNISHED AND INSTALLED FIXTURES AND EQUIPMENT. C. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL REQUIREMENTS, KEYED NOTES: OEXISTING RESTROOMS- EXISTING RESTROOM FIXTURES AND ACCESSORIES TO REMAIN. GC TO VERIFY ACCESSIBILITY COMPLIANCE, MODIFY AS REQUIRED. SEE SHEET A4 FOR MORE INFORMATION. OEXISTING MOP SINK: EXISTING MOP SINK TO REMAIN. OHI -LOW DRINKING FOUNTAIN: ( REFER TO M.E.P. PLANS ) OABOVE GROUND FLOOR SAFE: OWNER FURNISHED AND CONTRACTOR INSTALLED. OSHOWROOM CORNER BOX OUT: GC TO INSTALL PLYWOOD BACKING TO EACH FACE FROM 8' -0" TO 10' -0" A.F.F. FOR INSTALLATION OF SECURITY MIRRORS. OEXISTING STEEL COLUMN: EXISTING STEEL COLUMN TO REMAIN. GC TO PAINT "O'REILLY GREEN" IN SHOWROOM ONLY. OFIRE EXTINGUISHER: FIRE EXTINGUISHER IS TO BE MULTIPURPOSE DRY CHEMICAL TYPE, UL LISTED ABC, 10 LBS. CAPACITY, SURFACE MOUNTED WITH MANUFACTURER'S STANDARD METAL BRACKETS AND FASTENERS AT 42" ABOVE FINISHED FLOOR. VERIFY EXACT LOCATIONS WITH PROJECT ADMINISTRATOR. OEXISTING DOOR: EXISTING DOOR TO REMAIN. REPLACE EXISTING CORE WITH SCHLAGE 20 -068 x US26D -E (VERIFY WITH EXISTING DOOR.) /� EXISTING STOREFRONT: � EXISTING ALUMINUM & GLASS STOREFRONT SYSTEM TO REMAIN. GC TO REMOVE TINT AND CLEAN GLASS AS REQUIRED. 10 NEW STOREFRONT: NEW STOREFRONT ALUMINUM & GLASS SYSTEM TO MATCH EXISTING. SEE EXTERIOR ELEVATIONS AND SHEET A2 FOR ADDITIONAL INFORMATION. 11 WINDOW TINT: GC TO APPLY 3M NIGHT VISION 15 WINDOW TINT TO THE INSIDE FACE OF EXISTING GLAZING. NEXT, APPLY 3M FSARA MILANO ATOP THE 3M NIGHT VISION 15. REFER TO PLAN FOR LOCATIONS. (IF THERE ARE ANY QUESTIONS, CONTACT JOHN AGUZINO 3M 630 - 964 -1568) 12 EXISTING WATER METER: EXISTING WATER METER TO REMAIN. 13 EXISTING ELECTRICAL ROOM: EXISTING ELECTRICAL ROOM, INCLUDING DOOR, FRAME AND HARDWARE, TO REMAIN. GC TO INSTALL LOUVRE IN EXISTING DOOR FOR VENTILATION. ( REFER TO ELECTRICAL PLANS FOR EQUIPMENT INFORMATION) 14 TACTILE EXIT SIGNAGE: G.C. TO INSTALL TACTILE EXIT SIGNAGE. REFER TO 4/A4. 15 INTERNATIONAL SYMBOL OF ACCESSIBILITY: G.C. TO INSTALL INTERNATIONAL SYMBOL OF ACCESSIBILITY AT MAIN ENTRANCE. REFER TO 4/A4. 16 WALL TRIM: 1X4 WALL TRIM, PAINT TO MATCH WALL. TOP OF TRIM TO ALIGN WITH TOP OF NEW WALL. SEE 9 /A1.2 FOR ADDITIONAL INFORMATION. 17 NEW STUD COLUMN: NEW STUD COLUMN TO UNDERSIDE OF EXISTING STRUCTURE ABOVE. REFER TO SHEET A1.3 FOR ADDITIONAL INFORMATION. 18 NEW STUD COLUMN: NEW STUD COLUMN TO UNDERSIDE OF NEW TRUSS /HEADER SYSTEM. SEE A1.3 FOR ADDITIONAL INFORMATION. 19 NEW TELEPHONE BOARD: ( REFER TO ELECTRICAL PLANS) 20 NEW STOREFRONT VESTIBULE: NEW ALUMINUM & GLASS STOREFRONT SYSTEM TO MATCH EXISTING. SEE SHEET A2 FOR ADDITIONAL INFORMATION. DISTRIBU OWNER REVII PERMIT /BID A A A t TAT Li �f�1 Ex Professional c SHEETS BEARING THIS SEAL RESPONSIBILITY FOR ALL OT OR INSTRUMENTS ARE DISCL • • ■ W F y H d 0 a J J_ W O O LU C7 O C4 J •W cD 04 Q 00— cn - H Q O 2 � Lu O1---1 c a- O T– cn IZ • • ■ W F y H d 0 a J J_ W CHECKED: CI PARTITION WALL: 2 1/2" (20 GAUGE) METAL STUDS @ 16" O.C. WITH 5/8" GWB ON DATE: OE ONE SIDE ONLY. GWB TO 6" A.F.C. ATTACH TO STUDS AND PROVIDE VENTS AS SHOWN. BRACE WALL TO STRUCTURE AS REQUIRED. JOB NO.: 31 SHEET: _--, INTERIOR WALL SECTION A .A 5 AT STOREFRONT A1.1 j SCALE: 1 1/2" = V -0" SHEET 1 0 111' -6" J J •W 1- p 00 X EDGE O O 2 CL CC 108' -0" TOP OF WINDOW PROVIDE ONE LAYER 5/8" GWB ON 21/2" — — (20 GAUGE) MTL. STUDS @ 16" OC. C C i `D INSTALL 10" X 6" STAMPED STEEL BASE RETURN WALL VENT - a a PRE - FINISHED WHITE. INSTALL , , + + OPENING IN WALL AT FULL DEPTH OF WALL FOR VENTILATION. PLACE VENTS AT TOP AND BOTTOM OF U U, EACH STUD SPACE. KEEP STUD C Cr SPACES CLEAR OF OBSTRUCTIONS n n SO AS NOT TO INTERFERE WITH VENTILATION CD C° INSTALL TINTING ON INSIDE FACE OF EXISTING GLAZING. EXISTING ALUM. STOREFRONT FRAMING 4" VINYL BASE DRAWN: J J/ FINISH FLOOR 5 AT STOREFRONT A1.1 j SCALE: 1 1/2" = V -0" SHEET 1