HomeMy WebLinkAbout12100043.4EX'G
18
S41
5
V -8"
ol
1
EX'G1
11
A3
EXISTING
A3
PROPOSED
9
9 �
X
W
A O
A3 A3 _ MEN'S
PROPOSED EXISTING 8 TOILET RM.
- - -- -- -- - -- -
104
2 T
ELECTRICAL
UU 0
u� / �� 2 13
106
PARTS AREA "C" CO 1 12
M! 5
'103 `" ! � WOMEN'S
w • TOILET RM.
17 17 m 1� (19;: .
105
cn 4'A
�
co
A4 O 16
"' 3 ! A3
1 ` 0 EXISTING
v '
ABOVE N
18
43' -2 1/8" 1 16-9 7/8" 1 37' -4 318" A3
ao 7 3 5/8"
r` PROPOSED
17 iI
60' -0" '-n I I S44 O
(ABOVE) z
S46 CO
— — — — — — — °�, — w
I S44
6 M (ABOVE) 6
S 4 6 `O
ao EX'G `O
PARTS AREA "A" 17
100 1 o
17 I I S44 PARTS AREA
- 1 (ABOVE) " B" 101
S46
S44
c°n (ABOVE) 10
S46 11
S44 23 t7
O !
D o (ABOVE) A4
'n': 17 °' 16
T -6" w
4 0 4 ;r
14 A1.1 S42 \4 5 9
iv 1B ABOVE N OFFICE - 5 A1.1 11 10
5
C' 7 20 I ' a0 C' 102 S43 A1.1 A1.1 9
1k 1 11 1 w Co j< 14 I ' W 9' -0" W 11
u1
9 9 9 9 9 9 9 10 10 ;10 i B9 9- 9 9 9 9
10 11 <1 (,11) � i C11 11 11 11
..... ... _....... ..._
15' -7" EXISTING 15' -6 3/4" EXISTING 16' -7 1/4" EXISTING
100' -0" EXISTING
3 1
A3 A3
PROE599 EXISTING
5/8" TYPE 'X' GWB ON
(1) SIDE TO 11' -6" A.F.F.
i
(25 GA.) MTL.
STUDS AT 24" O.C.
TO 11' -6" A.F.F.
S41
S42
I
<o Q
S46
1 WALL TYPES
A1.1 SCALE: 1 1/2" = V -0"
6 FLOOR PLAN
A1.1 SCALE: 1/8" = V -0"
N
5/8" TYPE 'X' GWB EACH
SIDE TO 11' -6" A.F.F.
3 -5/8" (20 GA.) MTL. STUDS
AT 24" O.C. TO 11' -6" A.F.F.
REFER TO SHEET A1.3 FOR
MORE INFO
5/8" TYPE 'X' GWB EACH
SIDE TO 11' -6" A.F.F.
3/4" LATTICE TRIM
PEGBOARD OVER 1/2" WD.
BLOCKING @ 16" O.C.
3 -5/8" (20 GA.) MTL. STUDS AT
24" O.C. TO 11' -6" A.F.F. REFER
TO SHEET A1.3 FOR MORE INFO
5/8" TYPE 'X' GWB
EACH SIDE
3 -5/8" (20 GA.) MTL.
STUDS AT 24" O.C.
TO 8' -6" A.F.F.
3 1/2" U N FAC ED BAIT.
SOUND INSULATION
5/8" TYPE 'X' GWB EACH
SIDE TO 11' -6" A.F.F.
3 -5/8" (20 GA.) MTL. STUDS
AT 24" O.C. TO 11' -6" A.F.F.
REFER TO SHEET A1.3
FOR MORE INFO
S43 S44
NOTES:
1- REFER TO SHEET Al .3 FOR TYPICAL SECURING OF BASE OF NEW WALL CONSTRUCTION.
2. REFER TO 10/A1.2 FOR TYPICAL HEADER & JAMB STUD CONSTRUCTION AT NEW
INTERIOR WALLS.
3. PROVIDE FIRE STOPPING AND FIRE SEALANT MATERIALS AS REQUIRED AT ALL RATED
WALL CONSTRUCTION MATERIAL TRANSITIONS AND PENETRATIONS. RATING TO BE
EQUAL TO RATED WALL ASSEMBLY.
4. PROVIDE DIAGONAL BACKING BRACING (3" X 16 GA. FLAT STRIP) AT CORNER FACES OF
FREE STANDING PARTITION SYSTEMS.
5. PROVIDE MOISTURE RESISTANT TYPE 'X' GYPSUM BOARD IN TOILET ROOMS, BEHIND
MOP SINK AND BEHIND DRINKING FOUNTAIN.
6. PROVIDE 'J' MOLDING REGLETS OR CORNER BEAD AT ALL DISSIMILAR WALL MATERIAL
TRANSITIONS.
7. INSULATION SHALL HAVE A FLAME SPREAD RATING OF 0 -25 AND A SMOKE
DEVELOPMENT RATING OF 0-450.
EX'G1
3E
5/8" GWB
EXISTING WALL
4" VINYL BASE
FINISH FLOOR
DBL_ 3 5/8" (20 GA.)
MTL. STUDS @ C.J.
AS SH
„T ,. , ..6" (1) PIECE
VEE- SHAPED SLOT
CONTROL JOINT @ BOTH
SIDES OF HEADER
GWB
4 CONTROL JOINT
A1.1 SCALE: 1 1/2" = V -0"
GENERAL NOTES:
A. ALL DIMENSIONS TO ROUGH FACE OF ROUGH FRAMING, CONCRETE OR CENTERLINE
OF STRUCTURE, UNLESS OTHERWISE NOTED.
B. REFER TO SHEET F1 FOR INTERIOR FINISH REQUIREMENTS AND OWNER FURNISHED
AND INSTALLED FIXTURES AND EQUIPMENT.
C. REFER TO M.E.P. DRAWINGS FOR ADDITIONAL REQUIREMENTS,
KEYED NOTES:
OEXISTING RESTROOMS-
EXISTING RESTROOM FIXTURES AND ACCESSORIES TO REMAIN. GC TO VERIFY
ACCESSIBILITY COMPLIANCE, MODIFY AS REQUIRED. SEE SHEET A4 FOR MORE
INFORMATION.
OEXISTING MOP SINK:
EXISTING MOP SINK TO REMAIN.
OHI -LOW DRINKING FOUNTAIN:
( REFER TO M.E.P. PLANS )
OABOVE GROUND FLOOR SAFE:
OWNER FURNISHED AND CONTRACTOR INSTALLED.
OSHOWROOM CORNER BOX OUT:
GC TO INSTALL PLYWOOD BACKING TO EACH FACE FROM 8' -0" TO 10' -0" A.F.F. FOR
INSTALLATION OF SECURITY MIRRORS.
OEXISTING STEEL COLUMN:
EXISTING STEEL COLUMN TO REMAIN. GC TO PAINT "O'REILLY GREEN" IN SHOWROOM
ONLY.
OFIRE EXTINGUISHER:
FIRE EXTINGUISHER IS TO BE MULTIPURPOSE DRY CHEMICAL TYPE, UL LISTED ABC, 10
LBS. CAPACITY, SURFACE MOUNTED WITH MANUFACTURER'S STANDARD METAL
BRACKETS AND FASTENERS AT 42" ABOVE FINISHED FLOOR. VERIFY EXACT LOCATIONS
WITH PROJECT ADMINISTRATOR.
OEXISTING DOOR:
EXISTING DOOR TO REMAIN. REPLACE EXISTING CORE WITH SCHLAGE 20 -068 x US26D -E
(VERIFY WITH EXISTING DOOR.)
/� EXISTING STOREFRONT:
� EXISTING ALUMINUM & GLASS STOREFRONT SYSTEM TO REMAIN. GC TO REMOVE TINT
AND CLEAN GLASS AS REQUIRED.
10 NEW STOREFRONT:
NEW STOREFRONT ALUMINUM & GLASS SYSTEM TO MATCH EXISTING. SEE EXTERIOR
ELEVATIONS AND SHEET A2 FOR ADDITIONAL INFORMATION.
11 WINDOW TINT:
GC TO APPLY 3M NIGHT VISION 15 WINDOW TINT TO THE INSIDE FACE OF EXISTING
GLAZING. NEXT, APPLY 3M FSARA MILANO ATOP THE 3M NIGHT VISION 15. REFER TO
PLAN FOR LOCATIONS. (IF THERE ARE ANY QUESTIONS, CONTACT JOHN AGUZINO 3M
630 - 964 -1568)
12 EXISTING WATER METER:
EXISTING WATER METER TO REMAIN.
13 EXISTING ELECTRICAL ROOM:
EXISTING ELECTRICAL ROOM, INCLUDING DOOR, FRAME AND HARDWARE, TO REMAIN.
GC TO INSTALL LOUVRE IN EXISTING DOOR FOR VENTILATION.
( REFER TO ELECTRICAL PLANS FOR EQUIPMENT INFORMATION)
14 TACTILE EXIT SIGNAGE:
G.C. TO INSTALL TACTILE EXIT SIGNAGE. REFER TO 4/A4.
15 INTERNATIONAL SYMBOL OF ACCESSIBILITY:
G.C. TO INSTALL INTERNATIONAL SYMBOL OF ACCESSIBILITY AT MAIN ENTRANCE.
REFER TO 4/A4.
16 WALL TRIM:
1X4 WALL TRIM, PAINT TO MATCH WALL. TOP OF TRIM TO ALIGN WITH TOP OF NEW
WALL. SEE 9 /A1.2 FOR ADDITIONAL INFORMATION.
17 NEW STUD COLUMN:
NEW STUD COLUMN TO UNDERSIDE OF EXISTING STRUCTURE ABOVE. REFER TO SHEET
A1.3 FOR ADDITIONAL INFORMATION.
18 NEW STUD COLUMN:
NEW STUD COLUMN TO UNDERSIDE OF NEW TRUSS /HEADER SYSTEM. SEE A1.3 FOR
ADDITIONAL INFORMATION.
19 NEW TELEPHONE BOARD:
( REFER TO ELECTRICAL PLANS)
20 NEW STOREFRONT VESTIBULE:
NEW ALUMINUM & GLASS STOREFRONT SYSTEM TO MATCH EXISTING. SEE SHEET A2
FOR ADDITIONAL INFORMATION.
DISTRIBU
OWNER REVII
PERMIT /BID
A
A
A
t
TAT
Li �f�1
Ex
Professional c
SHEETS BEARING THIS SEAL
RESPONSIBILITY FOR ALL OT
OR INSTRUMENTS ARE DISCL
•
•
■
W
F
y
H
d
0
a
J
J_
W
O
O
LU
C7
O
C4
J
•W
cD
04
Q
00—
cn
-
H
Q
O 2
�
Lu
O1---1
c
a-
O
T–
cn
IZ
•
•
■
W
F
y
H
d
0
a
J
J_
W
CHECKED: CI
PARTITION WALL: 2 1/2" (20 GAUGE) METAL STUDS @ 16" O.C. WITH 5/8" GWB ON DATE: OE
ONE SIDE ONLY. GWB TO 6" A.F.C. ATTACH TO STUDS AND PROVIDE VENTS AS
SHOWN. BRACE WALL TO STRUCTURE AS REQUIRED. JOB NO.: 31
SHEET:
_--, INTERIOR WALL SECTION A .A
5 AT STOREFRONT
A1.1 j SCALE: 1 1/2" = V -0" SHEET 1
0
111' -6" J
J
•W
1- p
00
X EDGE O
O 2
CL CC
108' -0"
TOP OF WINDOW
PROVIDE ONE LAYER 5/8" GWB ON 21/2" —
—
(20 GAUGE) MTL. STUDS @ 16" OC. C
C
i
`D INSTALL 10" X 6" STAMPED STEEL
BASE RETURN WALL VENT - a
a
PRE - FINISHED WHITE. INSTALL ,
, +
+
OPENING IN WALL AT FULL DEPTH
OF WALL FOR VENTILATION. PLACE
VENTS AT TOP AND BOTTOM OF U
U,
EACH STUD SPACE. KEEP STUD C
Cr
SPACES CLEAR OF OBSTRUCTIONS n
n
SO AS NOT TO INTERFERE WITH
VENTILATION
CD C° INSTALL TINTING ON INSIDE FACE OF
EXISTING GLAZING.
EXISTING ALUM. STOREFRONT FRAMING
4" VINYL BASE
DRAWN: J
J/
FINISH FLOOR
5 AT STOREFRONT
A1.1 j SCALE: 1 1/2" = V -0" SHEET 1