Loading...
HomeMy WebLinkAbout12100043.7F1 11 HEAD SCALE: 1 1/2" - V -0" FOR INTERIOR WALL CONST. REFER TO FLOOR PLAN AND WALL TYPES BOX HEADER CONSISTING OF 2 - 6" (20 GA.) MTL. STUDS W/ 3 5/8" TRACK TOP AND BOTTOM. SEE 10/A1.2, SEALANT BOTH SIDES (TYP.) HOLLOW METAL FRAME, REFER TO DOOR SCHEDULE FOR TYPE (RATED WHERE REQUIRED) DOOR - SEE DOOR SCHEDULE NEW ALUM. STOREFRONT SYSTEM, REFER TO THE FLOOR PLAN AND STOREFRONT ELEVATION FOR ADDITIONAL INFORMATION. DOOR - SEEDOOR SCHEDULE. 6 I HEAD SCALE: 1 1/2" - V -0" 1 15' -7" 2„ 1,_2„ 2., 3'-0 4 1/2" " EQ. 2„ M M 12 JAMB A2 SCALE: 1 1 /2" • V-0" WHERE WALL OCCURS FOR INTERIOR WALL CONST. REFER TO FLOOR PLAN AND WALL SECTIONS SEALANT BOTH SIDES (TYP.) DOUBLE STUDS AT JAMBS. SEE 10/A1.2. INSTALL 3 (MIN.) JAMB ANCHORS EACH JAMB. FRAME REINFORCING PER MFR'S RECOMMENDATIONS AT ALL HARDWARE LOCATIONS. DOOR - SEE DOOR SCHEDULE. HOLLOW METAL FRAME, REFER TO DOOR SCHEDULE FOR TYPE (RATED WHERE REQUIRED) NEW ALUM. STOREFRONT SYSTEM, REFER TO THE FLOOR PLAN AND STOREFRONT ELEVATION FOR ADDITIONAL INFORMATION. CONTINUOUS SILL FLASHING AND SUB SILL SEALANT (TYP. BOTH SIDES) RETE FLOOR 7 SILL SCALE: 1 1/2" - 1' -0" NOTE: NEW ALUMINUM & GLASS STOREFRONT SYSTEM TO MATCH EXISTING. FIELD VERIFY ALL EXISTING COLOR, DIMENSIONS, GLAZING, AND FRAMING. EQ. EQ. 2 `t M rM T -8 1/2" EXISTING o FRAMING TO REMAI z N / M 7 CONTINUOUS SILL FLASHING EQUAL TO "EFCO" #IG65 (TYP.) 1 _� STOREFRONT ELEVATIONS A2 ) SCALE: 1/4" = V -0" M co M - DOOR SCHEDULE SET NUMBER 1 ( DOOR MARK I) o PART / o 0 0 FRAME DETAILS MK o HARDWARE 1 \ 1 E / 0 El / is GLAZING F KEYED TYPE MATERIAL HEAD JAMB 1A 3' -0" x T -0" A N `t M rM T -8 1/2" EXISTING o FRAMING TO REMAI z N / M 7 CONTINUOUS SILL FLASHING EQUAL TO "EFCO" #IG65 (TYP.) 1 _� STOREFRONT ELEVATIONS A2 ) SCALE: 1/4" = V -0" M co M - DOOR SCHEDULE NOTES: 1. ALL DOORS SHALL BE SHOP PREPARED FOR HARDWARE. 2. ALL EXTERIOR DOORS TO BE KEYED ALIKE. CONTRACTOR TO FIELD VERIFY AND MATCH CORE OF DOOR MARKED "1 ". 3. EXTERIOR DOOR, FRAME AND HARDWARE SUPPLIED BY OWNER, CONTRACTOR INSTALLED. 4. IT IS THE CONTRACTORS OPTION TO DIRECT ORDER AND PURCHASE INTERIOR DOORS, HOLLOW METAL FRAMES AND HARDWARE THROUGH LOCKNET. 5. FRAME FOR INDICATED DOOR TO HAVE A 4" HEAD. 100 COURCHELLE DRIVE PHONE 800 - 887 -4307 EXT 133 NICHOLASVILLE, KY 40356 FAX 859 -881 -5499 CONTACT: PAM PEEL EMAIL: construction @locknet.com NEW FRAMING 2" NEW GLAZING N M LO HOLLOW ALUMINUM STOREFRONT WELDED HOLLOW METAL FRAME SYSTEM THERMALLY BROKEN W/ (16 GA.) W/ (3) MIN. ANCHORS PER 1" INSUL. GLASS (REFER TO JAMB (REFER TO GENERAL FINISH GLAZING SCHEDULE THIS SHEET NOTES THIS SHEET FOR COLORS) FOR GLAZING TYPES.) 1 2 18 FRAME TYPES L!2 j SCALE: 3" • 1'•0" GENERAL FINISH NOTES FOR INTERIOR DOORS & FRAMES: A. WOOD DOORS SHALL BE CUSTOM GRADE ROTARY SLICED NATURAL BIRCH WITH FACTORY PREFINISH. FINISH SHALL BE EQUAL TO GRAHAM #300 - MEDIUM BROWN. ANY VARIANCE MUST BE APPROVED BY O'REILLY AUTO PARTS. B. INTERIOR HOLLOW METAL FRAMES SHALL BE SHOP PRIMED AND FIELD PAINTED WITH 2 COATS SEMI -GLOSS ENAMEL GLIDDEN "O'REILLY GREEN ". 1. FIELD VERIFY FINAL ROUGH OPENING PRIOR TO FABRICATION. 2. REFER TO COVER SHEET FOR DESIGN CRITERIA. 3. IT IS THE CONTRACTORS OPTION TO DIRECT ORDER AND PURCHASE STOREFRONT AND GLASS FROM COULTER & COMPANY. 4. SECURITY SHUTTERS MAY BE REQUIRED ON THIS PROJECT. CONTACT YOUR PROJECT ADMINISTRATOR FOR VERIFICATION. 5. WHEN THE WIND SPEED IS EQUAL TO OR GREATER THAN 120 MPH, A STORM PANEL SYSTEM WILL BE OWNER FURNISHED AND INSTALLED ON THIS PROJECT. CONTACT YOUR PROJECT ADMINISTRATOR TO VERIFY /COORDINATE. GLAZING SCHEDULE 1❑ =1" INSULATED SAFETY GLAZING ( 1/4" GREEN ( SOLEXIA) EXTERIOR PANE ) ( 1/4" CLEAR INTERIOR PANE) 2❑ =1" INSULATED GLAZING ( 114" GREEN ( SOLEXIA) EXTERIOR PANE) ( 1/4" CLEAR INTERIOR PANE) SHADING COEFFICIENT .57 1 T -6" v 4 /2" 3' -0" 2" 3'-7 4 1 2.. M M co N SET NUMBER 1 ( DOOR MARK I) PART / MANUFACTURER DOOR CYLINDER FRAME DETAILS MK 1 HARDWARE 1 0 1 SIZE (W x H x D) TYPE SWING MATERIAL GLAZING SET # KEYED TYPE MATERIAL HEAD JAMB 1A 3' -0" x T -0" A REFER TO ALUM. SET PUSH / PULLS 1 A 1 ALUM 61A2 6 /A2 (SIM.) 1 SWEEP RETRACTING RESILIENT SEAL TYPE FLOOR PLAN 1 THRESHOLD ANSI AND ADA COMPLIANT PEMKO SET NUMBER 2 ( DOOR MARK 2 ) NO. PART DESCRIPTION 1 B 3' -0" x T -0" A REFER TO ALUM. 1 A 1 ALUM 6 /A2 6 /A2 (SIM.) 20 -057 RIM CYLINDER IC, W/ SCHLAGE E KEYWAY (LARGE FORMAT) - 26D - W/ 2 SECURITY KEYS AND 1 CORE KEY PER LOCK, 1 BITTED SCHLAGE 1 FLOOR PLAN 8616DST HD GR 1, ADJ #3 x 689 FINISH W /COVER THRU- BOLTED ITEM W /SEX BOLT INCLUDES HOLD OPEN ARM W/ THUMBTURN DORMA 1 LATCHGUARD LG100Z /SF W /PIN W/ SEX BOLTS LATCHGUARD 1 KICKPLATE 2 EXISTING EX'G REFER TO E'XG 2 A E'XG E'XG E'XG E'XG SET WEATHERSTRIP JAMBS: KERFED QEBD -550 HEADER: ADHESIVE QDST -675 SCHLEGEL FLOOR PLAN DOOR VIEWER REFER TO IVES SET NUMBER 3 ( DOOR MARK 3 ) NO. PART DESCRIPTION MANUFACTURER 1 CYLINDER 20 -062 X US26D - "E" KEYWAY (REMOVABLE CORE) KEYED EXTERIOR SIDE REFER TO REQUIRED HARDWARE FURNISHED WITH STOREFRONT DOOR SYSTEM 1 DEADBOLT MS1850S X US28 ADAMS RITE 1 DEADLOCK LEVER 3 PAIR OF T -0" x T -0" AA STRIKE ALUM. GLAZING 3 A 1 ALUM 6/A2 6/A2 (SIM.) 195/188 X US26D RIXON 2 FLOOR PLAN CO -12 /CPII X US26D KAWNEER 1 SET WEATHERSTRIP WOOL PILE, CONT., REPLACEABLE PEMKO 2 SWEEP RETRACTING RESILIENT SEAL TYPE PEMKO 1 THRESHOLD ANSI AND ADA COMPLIANT SCHEDULE SET NUMBER 4 ( DOOR MARK 4 ) NO. PART DESCRIPTION MANUFACTURER 1 OFFICE LOCK SET AU5307LN X US26D YALE 1 WALL BUMPER 409 X US26D ROCKWOOD 1.5 PAIR HINGES BB 1279 X 4.5 X 4.5 X US26D HAGAR 4 T -0" x 7' -0" x 1 3/4" C REFER TO SOLID WOOD 1.5 4 - -_ 2 HOLLOW 11/A2 12/A2 YALE 1 FLOOR STOP FLOOR PLAN ROCKWOOD METAL 5 EXISTING EX'G REFER TO E'XG 5 - -- E'XG E'XG E'XG E'XG FLOOR PLAN 6 EXISTING EX'G REFER TO E'XG 5 - -- E'XG E'XG E'XG E'XG FLOOR PLAN NOTES: 1. ALL DOORS SHALL BE SHOP PREPARED FOR HARDWARE. 2. ALL EXTERIOR DOORS TO BE KEYED ALIKE. CONTRACTOR TO FIELD VERIFY AND MATCH CORE OF DOOR MARKED "1 ". 3. EXTERIOR DOOR, FRAME AND HARDWARE SUPPLIED BY OWNER, CONTRACTOR INSTALLED. 4. IT IS THE CONTRACTORS OPTION TO DIRECT ORDER AND PURCHASE INTERIOR DOORS, HOLLOW METAL FRAMES AND HARDWARE THROUGH LOCKNET. 5. FRAME FOR INDICATED DOOR TO HAVE A 4" HEAD. 100 COURCHELLE DRIVE PHONE 800 - 887 -4307 EXT 133 NICHOLASVILLE, KY 40356 FAX 859 -881 -5499 CONTACT: PAM PEEL EMAIL: construction @locknet.com NEW FRAMING 2" NEW GLAZING N M LO HOLLOW ALUMINUM STOREFRONT WELDED HOLLOW METAL FRAME SYSTEM THERMALLY BROKEN W/ (16 GA.) W/ (3) MIN. ANCHORS PER 1" INSUL. GLASS (REFER TO JAMB (REFER TO GENERAL FINISH GLAZING SCHEDULE THIS SHEET NOTES THIS SHEET FOR COLORS) FOR GLAZING TYPES.) 1 2 18 FRAME TYPES L!2 j SCALE: 3" • 1'•0" GENERAL FINISH NOTES FOR INTERIOR DOORS & FRAMES: A. WOOD DOORS SHALL BE CUSTOM GRADE ROTARY SLICED NATURAL BIRCH WITH FACTORY PREFINISH. FINISH SHALL BE EQUAL TO GRAHAM #300 - MEDIUM BROWN. ANY VARIANCE MUST BE APPROVED BY O'REILLY AUTO PARTS. B. INTERIOR HOLLOW METAL FRAMES SHALL BE SHOP PRIMED AND FIELD PAINTED WITH 2 COATS SEMI -GLOSS ENAMEL GLIDDEN "O'REILLY GREEN ". 1. FIELD VERIFY FINAL ROUGH OPENING PRIOR TO FABRICATION. 2. REFER TO COVER SHEET FOR DESIGN CRITERIA. 3. IT IS THE CONTRACTORS OPTION TO DIRECT ORDER AND PURCHASE STOREFRONT AND GLASS FROM COULTER & COMPANY. 4. SECURITY SHUTTERS MAY BE REQUIRED ON THIS PROJECT. CONTACT YOUR PROJECT ADMINISTRATOR FOR VERIFICATION. 5. WHEN THE WIND SPEED IS EQUAL TO OR GREATER THAN 120 MPH, A STORM PANEL SYSTEM WILL BE OWNER FURNISHED AND INSTALLED ON THIS PROJECT. CONTACT YOUR PROJECT ADMINISTRATOR TO VERIFY /COORDINATE. GLAZING SCHEDULE 1❑ =1" INSULATED SAFETY GLAZING ( 1/4" GREEN ( SOLEXIA) EXTERIOR PANE ) ( 1/4" CLEAR INTERIOR PANE) 2❑ =1" INSULATED GLAZING ( 114" GREEN ( SOLEXIA) EXTERIOR PANE) ( 1/4" CLEAR INTERIOR PANE) SHADING COEFFICIENT .57 1 T -6" v 4 /2" 3' -0" 2" 3'-7 4 1 2.. M M co N SET NUMBER 1 ( DOOR MARK I) PART / MANUFACTURER 1 CYLINDER 20 -062 X US26D - "E" KEYWAY (REMOVABLE CORE) KEYED EXTERIOR SIDE SCHLAGE REQUIRED HARDWARE FURNISHED WITH STOREFRONT DOOR SYSTEM 1 i 1 0 1 DEADLOCK LEVER 4550 X US28 ❑1 / L0 MS4002 X US28 ADAMS RITE 1 CLOSER 404OBC X AL ( ADJ. TO 5 #) LCN 11 / / PAIR OFFSET PIVOTS 195/188 X US26D RIXON 1 SET PUSH / PULLS CO -12 /CPII X US26D KAWNEER 1 SET WEATHERSTRIP WOOL PILE, CONT., REPLACEABLE tV 1 0 M 1 M r- 5' -4 1/2" 4 /2" 4' -7 1/2" 4 1 COULTER & COMPANY 13711 E. 66TH ST. N. OWASSO, OK 74055 PHONE: (918) 272 -4494 FAX: (918) 272 -7908 EMAIL: coulter- co @earthlink.net CONTACT: BRENDA OR KEN 6' -1 1/81 4 /2" 5' -4 1/8" 4 1 M D co M REMARKS REFER TO NOTE 1, 2 REFER TO NOTE 1, 2 REFER TO NOTE 2 REFER TO NOTE 1, 2 REFER TO NOTE 1, 4 REFER TO NOTE 4 REFER TO NOTE 4 HARDWARE SCHEDULE SET NUMBER 1 ( DOOR MARK I) NO. PART DESCRIPTION MANUFACTURER 1 CYLINDER 20 -062 X US26D - "E" KEYWAY (REMOVABLE CORE) KEYED EXTERIOR SIDE SCHLAGE REQUIRED HARDWARE FURNISHED WITH STOREFRONT DOOR SYSTEM 1 DEADBOLT MS1850S X US28 ADAMS RITE 1 DEADLOCK LEVER 4550 X US28 ADAMS RITE 1 STRIKE MS4002 X US28 ADAMS RITE 1 CLOSER 404OBC X AL ( ADJ. TO 5 #) LCN 1 PAIR OFFSET PIVOTS 195/188 X US26D RIXON 1 SET PUSH / PULLS CO -12 /CPII X US26D KAWNEER 1 SET WEATHERSTRIP WOOL PILE, CONT., REPLACEABLE PEMKO 1 SWEEP RETRACTING RESILIENT SEAL TYPE PEMKO 1 THRESHOLD ANSI AND ADA COMPLIANT PEMKO SET NUMBER 2 ( DOOR MARK 2 ) NO. PART DESCRIPTION MANUFACTURER 1.5 PAIR HINGES ECBB1100 - 4.5" X 4.5" - NRP, US26D HAGER 1 EXIT DEVICE 9300 B 486 / 689 - PRT03 630 THRU - BOLTED ITEM W / SEX BOLTS DORMA 1 RIM CYLINDER 20 -057 RIM CYLINDER IC, W/ SCHLAGE E KEYWAY (LARGE FORMAT) - 26D - W/ 2 SECURITY KEYS AND 1 CORE KEY PER LOCK, 1 BITTED SCHLAGE 1 DOOR CLOSER 8616DST HD GR 1, ADJ #3 x 689 FINISH W /COVER THRU- BOLTED ITEM W /SEX BOLT INCLUDES HOLD OPEN ARM W/ THUMBTURN DORMA 1 LATCHGUARD LG100Z /SF W /PIN W/ SEX BOLTS LATCHGUARD 1 KICKPLATE 8 X 34 X.050 SS FINISH HAGER 1 THRESHOLD 36" ALUM MILL ADA COMPLIANT POSTEL 1 SWEEP CONCEALED ALUM MILL VINYL BULB POSTEL 1 SET WEATHERSTRIP JAMBS: KERFED QEBD -550 HEADER: ADHESIVE QDST -675 SCHLEGEL 1 DOOR VIEWER 69813-190 DEGREE WIDE ANGLE - 26D IVES SET NUMBER 3 ( DOOR MARK 3 ) NO. PART DESCRIPTION MANUFACTURER 1 CYLINDER 20 -062 X US26D - "E" KEYWAY (REMOVABLE CORE) KEYED EXTERIOR SIDE SCHLAGE REQUIRED HARDWARE FURNISHED WITH STOREFRONT DOOR SYSTEM 1 DEADBOLT MS1850S X US28 ADAMS RITE 1 DEADLOCK LEVER 4550 X US28 ADAMS RITE 1 STRIKE MS4002 X US28 ADAMS RITE 2 CLOSER 404OBC X AL ( ADJ. TO 5#) LCN 2 PAIR OFFSET PIVOTS 195/188 X US26D RIXON 2 SET PUSH / PULLS CO -12 /CPII X US26D KAWNEER 1 SET WEATHERSTRIP WOOL PILE, CONT., REPLACEABLE PEMKO 2 SWEEP RETRACTING RESILIENT SEAL TYPE PEMKO 1 THRESHOLD ANSI AND ADA COMPLIANT PEMKO SET NUMBER 4 ( DOOR MARK 4 ) NO. PART DESCRIPTION MANUFACTURER 1 OFFICE LOCK SET AU5307LN X US26D YALE 1 WALL BUMPER 409 X US26D ROCKWOOD 1.5 PAIR HINGES BB 1279 X 4.5 X 4.5 X US26D HAGAR SET NUMBER 5 ( DOOR MARK 5 AND 6 ) NO. PART DESCRIPTION MANUFACTURER 1.5 PAIR HINGES BB 1279 X 4.5 X 4.5 US26D HAGAR 1 PRIVACY LOCKSET AU5302LN X US26D YALE 1 FLOOR STOP 440 X US26D ( MOUNT AS CLOSE TO CORNER AS POSSIBLE) ROCKWOOD SECTION 08 4113 ALUMINUM ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.01 SUMMARY A. PROVIDE ALUMINUM ENTRANCES AND STOREFRONTS. 1. EXTERIOR ENTRANCE DOORS. 2. FRAMES AND ENTRANCES. 3. STOREFRONT TYPE FRAMING SYSTEMS. 4. TRANSOMS. 5. SIDELIGHTS. 1.02 SUBMITTALS A. NONE REQUIRED UNLESS SUBMITTING FOR APPROVED EQUALS. 1.03 QUALITY ASSURANCE A. COMPLY WITH GOVERNING CODES AND REGULATIONS. PROVIDE PRODUCTS OF ACCEPTABLE MANUFACTURERS, WHICH HAVE BEEN IN SATISFACTORY USE IN SIMILAR SERVICES FOR THREE YEARS. USE EXPERIENCED INSTALLERS- DELIVER, HANDLE AND STORE MATERIAL IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. PROVIDE FIVE YEAR WARRANTY UNDER PROVISIONS OF GENERAL CONDITIONS INCLUDING COVERAGE FOR INSULATED GLASS UNITS. 1.04 TEST PROCEEDURES AND PERFORMANCE A. PROVISIONS FOR THERMAL MOVEMENTS: SYSTEM PERFORMANCE TO PROVIDE FOR EXPANSION AND CONTRACTION WITHIN SYSTEM COMPONENTS CAUSED BY TEMPERATURE CYCLING RESULTING FROM A SURFACE TEMPERATURE RANGING FROM 0- TO 180° F WITHOUT CAUSING BUCKLING, STRESSING ON GLASS, FLAURE OF JOINT SEALS,UNDUE STRESS ON STRUCTURAL ELEMENTS, DAMAGING LOADS ON FASTENERS, REDUCTION OF PERFORMANCE, OR OTHER DETRIMENTAL EFFECTS. OPERATING DOORS AND WINDOWS SHALL FUNCTION NORMALLY OVER THIS TEMPERATURE RANGE. B. TEST PROCEDURES AND PERFORMANCE: 1. AIR INFILTRATION: a. TEST UNITS IN ACCORDANCE WITH ASTM E 283 AT STATIC AIR PRESSURE DIFFERENCE OF 6.24 PSI. b. AIR INFILTRATION SHALL NOT EXCEED 0.06 CMF /FT MAXIMUM PER SQUARE FOOT OF FIXED WALL AREA. 2. WATER RESISTANCE: a. TEST UNITS IN ACCORDANCE WITH ASTM E 331. b. THERE SHALL BE NO WATER LEAKAGE AT A STATIC PRESSURE OF 12.0 PSF. 3. UNIFORM LOAD DEFLECTION: a. TEST UNITS IN ACCORDANCE WITH ASTM E 330 b- DESIGN AND SIZE MEMBERS TO WITHSTAND NOT LESS THAN 30 PSF MINIMUM POSITIVE AND NEGATIVE DESIGN WIND PRESSURE NORMAL TO THE PLANE OF THE WALL, UNLESS GREATER LOADS ARE REQUIRED BY LOCAL CODE REQUIREMENTS. C. DEFLECTION UNDER DESIGN LOAD SHALL NOT EXCEED L/175 OF THE CLEAR SPAN. 4. STRUCTURAL UNIFORM LOAD: a. TEST UNITS IN ACCORDANCE WITH ASTM E 330 AT NOT LESS 1.5 TIME THE DESIGN WIND PRESSURE SPECIFIED (MINIMUM 60 PSF). b. AT CONCLUSION OF THE TEST, THERE SHALL BE NO GLASS BREAKAGE, PERMANENT DAMAGE TO FASTENERS, STOREFRONT PARTS, OR ANY OTHER DAMAGE THAT WOULD CAUSE THE STOREFRONT TO BE DEFECTIVE. 5. CONDENSATION RESISTANCE FACTOR: a. TEST UNITS IN ACCORDANCE WITH ASTM 1503.1. b. CONDENSATION RESISTANCE FACTOR (CRF) SHALL NOT BE LESS THAN 59. 6. THERMAL TRANSMITTANCE: a. TEST UNITS IN ACCORDANCE WITH ASTM 1503.1. b. CONDUCTIVE THERMAL TRANSMITTANCE (U- VALUE) SHALL NOT BE LESS THAN 0.63 BTU /HR/DEGREE F /SF. PART 2 - PRODUCTS 2.01 MATERIAL A. GLAZING: MEETING REQUIREMENTS OF SECTION 08 80 00 AND AS SCHEDULED ON DRAWINGS. B. MANUFACTURERS: EFCO "S -403" SPECIFIED. APPROVED EQUALS: KAWNEER "TRIFAB 4517 AND VISTAWALL "FG- 3000 -S. C. ALUMINUM ENTRANCES AND STOREFRONT: 1. FRAMING: a. SIZE: 2 "x 4 1/2 ", HEAVY DUTY MULLION EFCO SERIES 9314/9323, Ixx- 8.207. b. ALUMINUM: 6063 T5 OR T6 ALLOY AND TEMPERED, MEETING REQUIREMENTS OF ASTM B 221, ALLOY GS 10A -T5. c. CONSTRUCTION: THERMAL BROKEN WITH SCREW SPLINE CONNECTIONS PER MANUFACTURERS STANDARDS. d. GLAZING STOPS: SNAP IN TYPE WITH "DRY" EDPM GASKETS ON BOTH EXTERIOR AND INTERIOR. UNITS SHALL BE 1 -INCH INSULATED DOUBLE GLAZED CONSISTING OF 1/4 -INCH EXTERIOR PANE, 112 -INCH AIR SPACE, 1/4 -INCH INTERIOR PANE INSTALL FROM EXTERIOR SIDE. e. FASTENERS: ALUMINUM OR NON - MAGNETIC STAINLESS STEEL. CONCEALED FASTENERS SHALL BE CADMIUM OR ZINC - PLATED STEEL. 2. DOOR TYPE: a. SIZE: AS SCHEDULED. EFCO SERIES NUMBER D300. b. ALUMINUM: 6063 T5 OR T6 ALLOY AND TEMPERED, MEETING REQUIREMENTS OF ASTM B 221, ALLOY GS 10A -T5. c. STILES AND TOP RAILS: 3 -1 /2 "x 1 -3 /4 "x 0.125" THICK, PLUS OR MINUS 0.005, GLAZING STOP SECTION 0.050" WALL THICKNESS. d. BOTTOM RAIL: 10" MINIMUM x 1 -3 /4 "x 0.125" THICK, PLUS OR MINUS 0.005, GLAZING STOP SECTION 0.050" WALL THICKNESS. e. CONSTRUCTION: MANUFACTURERS STANDARD f. GLAZING STOPS: SNAP IN TYPE WITH "DRY" EDPM OR NEOPRENE BULB -TYPE GLAZING. UNITS SHALL BE DOUBLE GLAZED, 1 -INCH INSULATED UNIT, FROM EXTERIOR SIDE. g. WEATHERSTRIPPING: NEOPRENE BULB TYPE, REPLACEABLE. 3. FINISH: ORGANIC, AA- M12- C42 -R1X, KYNAR 500 /HYLAR 5000 FLUROPON, IN ACCORDANCE WITH AAMA 605.2. COLOR AS SELCECTED FROM MANUFACTURERS STANDARDS AND SCHEDULED ON DRAWINGS. 4. DOOR HARDWARE: REFER TO DOOR HARDWARE SCHEDULE AND SECTION 08 7100. D. AUXILLIARY MATERIALS: 1. PROVIDE ALL OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE, WEATHERTIGHT, AND PROPER INSTALLATION OF DOORS AND FRAMING SYSTEMS, SUBJECT TO ACCEPTANCE BY THE ARCHITECT. a. DEFLECTION CHANNELS: AS RECOMMENDED BY SYSTEM MANUFACTURER. b. CONTINOUS SILL FLASHING SHEET METAL: 0.040 -INCH THICK ALUMINUM SHEET, FINISH TO MATCH MULLION SECTIONS WHERE EXPOSED. c. COLUMN CLADDING SHEET METAL: 0.040 -INCH THICK ALUMINUM SHEET, FINISH TO MATCH MULLION SECTIONS WHERE EXPOSED. d. THERMAL BARRIER: BARRIER MATERIAL SHALL BE POURED -IN -PLACE TWO PART POLYURETHANE. A NONSTRUCTURAL THERMAL BARRIER IS UNACCEPTABLE. PART 3 - EXECUTION 3.01 INSTALLATION A. TAKE FIELD MEASUREMENTS BEFORE FABRICATION WHERE POSSIBLE; DO NOT DELAY JOB PROGRESS. B. INSTALL MATERIAL AND SYSTEMS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. INSTALL MATERIALS AND SYSTEMS IN PROPER RELATION WITH ADJACENT CONSTRUCTION AND WITH UNIFORM APPEARANCE. COORDINATE WITH WORK OF OTHER SECTIONS. C. ANCHOR SECURLY IN PLACE TO STRUCTURE; INSTALL PLUMB, LEVEL AND IN TRUE ALLIGNMENT. ISOLATE DISSIMILAR MATERIALS TO PREVENT CORROSION. D. COORDINATE WITH GLASS AND GLAZING WORK; INSTALL HARDWARE AND ADJUST FOR SMOOTH, PROPER OPERATION. E. SEAL FRAMES WITH AN APPROVED SEALANT, IN COMPLIANCE WITH SECTION 07 92 00, IN COLOR TO MATCH FRAMES. MAKE A NEAT, FULLY WEATHERPROOF JOB. F. CLEAN AND PROTECT COMPLETED SYSTEM; REPAIR DAMAGE, END OF SECTION I II L - -LI HOLLOW ALUMINUM DOOR SYSTEM W/ SAFETY GLASS (REFER TO GENERAL FINISH NOTES AND GLAZING SCHEDULE ON THIS SHEET FOR COLORS & GLAZING) Al 4 A2 ( NOT USED) B \FOR SOLID CORE WOOD (REFER TO GENERANOTES ON THIS SHE FINISHES) C(K�__ NOT E: DASHED IN DOOR AND DOUBLE LETTER INDICATE DOORELEVATIONS PAIRED DOOR LOCATIONS SCALE: 1/4"=1'-&' DISTRIBU OWNER REVII PERMIT /BID • 0 E ® DI Al lee AR' Exp. Date: 1 Professional i SHEETS BEARING THIS SEAL RESPONSIBILITY FOR ALL 01 OR INSTRUMENTS ARE DISCI U) w a p o O N E acc 0 En 0 - U� W Otis a� C c �Oa-' 00 cna r- N N Q d O a moil G3 0C c C f� I` N N F cc IL F a J J J .W F- 0 p U ■ DRAWN:_ J) CHECKED: C ' DATE: 0f JOB NO.: 3' SHEET: Al SHEET 4