HomeMy WebLinkAbout0778.97.1i-E : THIS DRAWING IS BASED ON CONSTRUCTION PLANS OR RECORD )RAWINGS AND IS NOT BASED UPON A FIELD SURVEY. SCHNEIDER _NGINEERING CORP. DOES NOT WARRANT THE ACCURACY OR SUFFICIENCY OF THIS INFORMATION. THE CONTRACTOR SHOULD ✓ ERIFY EXISTING CONDITIONS PRIOR TO ANY CONSTRUCTION. ANY )ISCREPANCY FOUND UPON THIS DRAWING SHOULD BE REPORTED f0 SCHNEIDER ENGINEERING CORP. IMMEDIATELY; FAILURE TO DO 30 WILL RESULT IN THE CONTRACTORS ASSUMPTION OF LIABILITY. X90 J NOTE: THE BASEMENT ELEVATION DEPICTED HEREON HAS BEEN DETERMINED AND BASED UPON THE PAD GRADES AND OR CONTOURS TAKEN FROM THE CONSTRUCTION Pt,ANS FOR THE SUBDIVISION. UNLESS STATED, NO INFORMATION ABOUT FLUCTUATING WATER TABLES, SOIL CONDITIONS OR SOIL TYPES WITHIN THE BUILDING AREA HAS BEEN PROVIDED OR STATED ON SAID PLANS. IT IS RECOMMENDED THAT BASEMENT FINISHED FLOOR ELEVATIONS BE AT LEAST (1) FOOT ABOVE THE NORMAL POOL ELEVATION OF ANY ADJOINING BODIES OF WATER UNLESS A t.STUDY OF FACTS REVEALS OTHERWISE. 0 122.72' M.E. 15'DU &SE 02.3 - - - - -- - ---- - -�6T' SSD- ---- - - - - -- - - - - - - - - -- - - -- CONTRACTOR TO VERIFY INV. r ELEVATION OF 6" SSD CONNECTION 2' 9 TO BE 898.4 OF LESS. " PERIMETER DRAIN INV. := 898.7 I 0 2.1 4' PERIMETER DRAIN ; 02.0 ; 1.0' I 903.4 10.0' --- -- INV. = 898.5 r 1(TYP. I i -L- 903.4 ' 10.0' ( TYP. ) ( TYP)`-- -� 110 , 0 Ir 4x PER F PVC 4" UNPERF PVC (TYP) I' ' r I I ; 903.4 r 7 , 5' r ' 0 ' 1.0'rt�- _ - ( TYP. 3.4 ____ _ INV. 898.91 I I 10.0' DIST. INV. = 898.7 ( TYP.) BOX I '�0 281.0' 40.0':- I I I Ln 03.7 LO I LOT # 18 0 r9 I 48,322 SF 0� Y PVC _ ^ L1J \ i I I FORCE L i I I MAIN Q I z i 1 -) I i 1000 GAL. I 111 i ( DOSING TANK I 1250 GAL. 0 3.9 �-- O i I I SEPTIC TANK d- j In i In I 13.5' In p.aar I e'x,l DE TB M o °� ,OM 1: 41.8' rU1� ms, 8 teas 9 5.13 I ,a.oa� TC- 903.21 \ PER STM SEWER I / A WWI FM RECORD DRAWIN �% 1 896.8 rn DATED 4/6/90 1 t, � g04. 04.6 II I N I a 50 BL 0 O p ASSUMED NORTH SCALE 1" = 30' SEPTIC FIELD TO BE FENCED OFF FROM CONSTRUCTION TRAFFIC DURING CONSTRUCTION. I Ijj 40'X35 I I 1.0' w N L &WME I 5 I i 02.8 F- CWVE «j II I , 3 S 4 I _ I �v w �� - - `-i I I HYDRANT 121.2 9 W 03" a� 4'WALK / W -- -� APRON II 10'X25' SIGN ESMT AR R/W V NOTE: GARAGE F.F.E. IS PROPOSED TO BE 7.6' ABOVE T8M AT STM SWR STRUCTURE OUTLET TO ABSORPTION FIELD DISTR%TI0N Box 2• PVC FORCE MAIN FROM DOSING TANK 1 1" LONG RADIUS 9(r ELBOW DISTRIBUTION BOX DETAIL NOT TO SCALE 9 ELEV- 904.0 1 L: CONTROLS AND AUDIO /VISUAL ALARM TO BE LOCATED IN DWELLING AS DIRECTED BY OWNER 48" PRECAST CONCRETE ASTM C478 WITH .� "0" -RING GASKET ASTM C923 o. a. INFLUENT ELEV HIGH WATER ALARM `t ELEV 900.2 PUMP ON ELEV 899.9 DOSE VOLUME PUMP OFF v GAL. ELEV BOTTOM ELEV 893.4 P1 1if '® r . GUIDE RAILS 80 z TO DISTRIBUTION BOXES i 40 - IN V- 901.2 O BREAKAWAY FLANGES DOSING TANK & PUMP ( 1,000 Gal.) (NOT TO SCALE) SECURE GAS TIGHT INSPECTION r/,� \ PLUG VA MANHOLE FINISHED GRADE " MINIMUM I ET ... f - 6 PVC LIQUID LEVEL MIN .15 "D" SDR 35 3 "MINIMUM 6" MINIMUM T- 2" I GAS WALL 8'-12' LIQUID DEPTH "D" 30" TO 78" THICKNESS } REINFORCED DEFLECTION CONCRETE BAFFLE MINIMUM 2.5" t t BOTTOM THICKNESS INSIDE LENGTH 4" TO 6" �- OVTLET VC SDR 35 2" SEPTIC TANK (1,250 Gal.) (NOT TO SCALE) 4% EARTH FILL BARRIER* 4" PVC ,:••;•" SDR 35 • •; e'• * BARRIER MATERIAL SYNTHETIC FILTER FABRIC FINISHED GRADE -7 15" EXIST. BARRIER* / GRADE ;s � e e'• O . .• •0. ,•. CLEAN GRAVEL 36" 1/2- TO 2 1/2- (WASHED L -ROCK) SECTION OF ABSORBTION FIELD EXISTING GRADE o ° , •; o'• ° v BARRIER e ° o o'• °; e °.�. 0 0 • ° ., 0 •. CLEAN GRAVEL o ° ° •; 1/2" TO 2 1/2" ' . ° (WASHED L -ROCK) 'e000. NOTE: � ° ,. 0 e GRAVEL ENVELOPE AROUND THE .0 0 . 0 0 PERIMETER DRAIN SHALL EXTEND ° :.o o'• WITHIN 6" OF THE EXISTING ° SURFACE. o'• ° e ° •• • o •o • o e .• r .. °° to . . °° 0 • a .°a•• 4" PERFORATED PVC o'• o• NOTE: GLACIAL TILL LAYER n SIDEWALK TO BE PLACED V FROM PROPERTY LINE, 5' FROM BACK OF CURB, PER PLAN. 00.0 PROPOSED GRADE CONTOURS TAKEN FROM DEVELOPMENT PLAN 12" NOTE: BARRIER MATERIAL SHALL BE SYNTHETIC FILTER FABRIC 1 42" MIN. 4 PERIMETER DRAIN I tI� PERIMETER DRAIN DETAIL T 18" 4" I 20 0 0 20 40 60 80 100 120 U.S. GALLONS PER MINUTE MODEL TYPE DISCH. (in') hp CAPACITIES SOLIDS (inches) GPM to (feet) HEADS to (feet) OSP33 Automatic and Manual 1 1/4 113 60 25 3/8 PUMP PERFORMANCE DATA GroAy Sewer PVC ASTM -D 2665 for 4-Indn and 6 -Inch pips only ASTM -D 3033 SDR 35 for 4 -Inch pipe; SDR 41 for 6 -Inch through 15-hch pipe ASTM -D 3034 SDR 35 for 4 -inch through 15-Inch pips Pressure sewer, SDR 26, with compression Mthp for special crossing conditions with potable water lines. Force Male Any PVC or AIRS pipe listed below for potable water or else PVC ASTM-D 1165 Schedule 40. 80. or 120 ConVessim fill" must be used In crossing situations with potable water lines Absorption Field Loterds 1. Sewer pipe listed above or potable water pips (at leod 4-Indnss In d rWer) listed below, ss well as pipe meeting ASTM -D 2729 or ASTM FMO-U are occeptable for absorption Field gravity lotuds. 2. The pipe must have perforations with the equivalent told opening as o cornparable lie laid with 1/4-Inch open )Dints per foot of tie, with the following provisions: a. Three rove of holes b. 112 -inch to 3/4 -inch dameter holss, with: 1/2 -inch holes at 2 1/4 inch. or closer spacing 5/8 -inch holes at 3 1/2 inch, or closer spacing 3/4-" Ades at 5 Inch, or closer spacing c. Equal separation of rolie around the ckawnference. 3. The pipe must be delivered in stroight (uncoiled) kngths Potable Water The pipe must have the NSF (Notional Sanitation Foundation) sed far potable water and be rated to withstand the applied pressure. Solvent -weld fittings are not acceptable POLYETHYLENE 160 p.s.L SDR 7 in 314 -inch, 1 -Inch and 1 1/4 -inch dameters only. PVC ASTM -D 2241 SDR 13.5, 17, 21, or 26 ABS ASTM -D 1527 Schedule 40, 80 ASTM -D 2282 SDR 13.5. 17, 21, or 26 LIST OF ACCEPTABLE PLASTIC PIPE NOTES 1. CONTRACTOR SHALL INSTALL A MINIMUM OF 2000 SQUARE FEET OF TRENCH BOTTOM AREA OR 667 LINEAL FEET OF 3 -FOOT WIDE TRENCHES. 2. TRENCHES SHALL BE SPACED 7.5 FEET ON CENTERS AND INSTALLED PARALLEL TO EXISTING SITE CONTOURS. TRENCHES SHALL BE INSTALLED LEVEL ALONG ENTIRE LENGTH. 3. THE TRENCH BOTTOM DEPTH MAY NOT EXCEED 18 INCHES BELOW EXISTING GRADE. 4. THE SITE OF THE PROPOSED ABSORPTION FIELD MUST BE PROTECTED FROM COMPACTING, GRADING AND FILLING PRIOR TO SYSTEM INSTALLATION OR THE SITE MAY BE RENDERED USELESS, 5. SEPTIC TANKS AND ABSORPTION FIELDS MAY BE CONSTRUCTED NO CLOSER THAN 5 FEET TO A PROPERTY LINE, OR CLOSER THAN 10 FEET TO A DWELLING OR OTHER STRUCTURE. MAINTAIN A 50' SEPARATION FROM ANY PRIVATE WATER SUPPLY WELL 6. ALL OPENINGS AND SURFACES OF THE SEPTIC TANK SHALL BE SEALED TO PREVENT GROUNDWATER LEAKAGE INTO THE SYSTEM. 7. THE 2" FORCE MAIN FROM THE DOSING TANK CONNECTING THE PUMP TO THE DISTRIBUTION BOX SHALL BE ADEQUATELY BAFFLED OR AN ELBOW INSTALLED IN THE DISTRIBUTION BOX TO PREVENT DIRECT DISCHARGE TO ANY OUTLETS WHICH WOULD OVERLOAD INDIVIDUAL TRENCHES. UNPERFORATED 4" PIPING SHALL BE INSTALLED FROM THE BOXES TO EACH TRENCH, AT WHICH POINT CONVENTIONAL 4' PERFORATED PIPING SHALL BE INSTALLED. 8. DOSING PUMP SHALL BE HYDROMATIC MODEL OSP33 OR EQUAL. PUMP SHALL DELIVER 48 GPM 0 12 FT TDH. 9. NO TRAFFIC SHALL BE PERMITTED ON THE PROPOSED SEPTIC ABSORPTION FIELD AREA. 10. ADDITIONAL SOIL COVER TO BE PLACED ABOVE EXISTING GRADE AFTER CONSTRUCTION TO PROVIDE A MINIMUM OF 15" OF SOIL ABOVE THE FILTER FABRIC FOR FREEZE PROTECTION. 11. CONSTRUCTION OF SEPTIC SYSTEM SHALL BE CONDUCTED ONLY WHEN SOILS ARE DRY. 12. ONLY TOPSOIL, NOT CLAY MATERIAL, SHALL BE PLACED OVER THE ABSORPTION FIELD. 13. FINISH GRADE TO OBTANV POSITIVE SURFACE DROAGE AWAY FROM FIELD. 14. FOLLOWING INSTALLATION, BUT PRIOR TO BACKFL1ING OF SEPTIC FIELD TRENCHES, HAMILTON COUNTY HEALTH DEPARTMENT SHALL BE NOTITD FOR INSPECTION. 16. ALL CONSTRUCTION ACTIVITY ON THIS SITE SHALL BE PERFORMED IN COWUANCE WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY. 17. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERFY ALL EXISTING UTILITIES AND CONDITIONS PERTANNING TO FNS PHASE OF WORK. THE CONTRACTOR SHALL NOTY IN WRITING THE OWNER OR THE ENGWR OF ANY CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN FIELD BEFORE WORK IS STARTED OR RESUMED. mom MOM SAU " DON'T DIG BLIND it 1= 800 -382 =5544 CALL TOLL FREE 1-800= 4284200 FOR CALLS OUTSIDE OF INDIANA PER INDIANA STATE LAW IS -69 -1991. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. Revisions 010, 07 CERTM BY TH6 OWNING AIO THE VM DESIGNS AND OOWVn C00M NM ARE M DJ01W NTEIIECTM PROPERTY OF SOM ENGw1FDtit10 OOIIPORArM AND ARE NOT TO aF USED OR REPA001 M MM OR N PART, 11 IT TIE TRIITIDI O3Wff OF SOME] DIGIN ENIC cormTlol. 01996, Schneider Engineering Corporotiol r Schneider 3020 North Post Road M*Merin . Indianapolis, Indiana Surveying 46226 -0068 Landwape 317 - 888 -8282 GI3 w U3 317 - 899 -8010 Fax Geology A ?"taw" 20" with li d&n. 11sysr. 01bees ! Asseektee, DAVID VMACORTA LOT # 18 LARKSPUR HamUton County, Indiana Septic System Design Plot Plan Date Project No. Drs A� 10/04/96 96- 1891 -14 BSC Computer Files Sheet No. � \14- 98\p11C:S \1800 \96189114.01NG