THIS DRAWING IS BASED ON CONSTRUCTION PLANS OR RECORD
)RAWINGS AND IS NOT BASED UPON A FIELD SURVEY. SCHNEIDER
_NGINEERING CORP. DOES NOT WARRANT THE ACCURACY OR
SUFFICIENCY OF THIS INFORMATION. THE CONTRACTOR SHOULD
✓ ERIFY EXISTING CONDITIONS PRIOR TO ANY CONSTRUCTION. ANY
)ISCREPANCY FOUND UPON THIS DRAWING SHOULD BE REPORTED
f0 SCHNEIDER ENGINEERING CORP. IMMEDIATELY; FAILURE TO DO
30 WILL RESULT IN THE CONTRACTORS ASSUMPTION OF LIABILITY.
X90
J
NOTE:
THE BASEMENT ELEVATION DEPICTED HEREON HAS BEEN DETERMINED AND
BASED UPON THE PAD GRADES AND OR CONTOURS TAKEN FROM THE
CONSTRUCTION Pt,ANS FOR THE SUBDIVISION. UNLESS STATED, NO
INFORMATION ABOUT FLUCTUATING WATER TABLES, SOIL CONDITIONS OR
SOIL TYPES WITHIN THE BUILDING AREA HAS BEEN PROVIDED OR STATED
ON SAID PLANS. IT IS RECOMMENDED THAT BASEMENT FINISHED FLOOR
ELEVATIONS BE AT LEAST (1) FOOT ABOVE THE NORMAL POOL ELEVATION
OF ANY ADJOINING BODIES OF WATER UNLESS A t.STUDY OF FACTS
REVEALS OTHERWISE.
0 122.72' M.E.
15'DU &SE 02.3
- - - - -- - ---- - -�6T' SSD- ---- - - - - -- -
- - - - - - - -- - - -- CONTRACTOR TO VERIFY INV.
r ELEVATION OF 6" SSD CONNECTION
2' 9 TO BE 898.4 OF LESS.
" PERIMETER DRAIN
INV. := 898.7
I 0 2.1 4' PERIMETER DRAIN ;
02.0 ; 1.0'
I 903.4 10.0' --- -- INV. = 898.5
r 1(TYP.
I i -L- 903.4 ' 10.0' ( TYP. )
( TYP)`-- -�
110 , 0
Ir
4x PER F
PVC
4" UNPERF PVC (TYP)
I'
' r
I I ; 903.4 r
7 , 5'
r
' 0 '
1.0'rt�- _ - ( TYP. 3.4
____ _
INV. 898.91
I I 10.0' DIST. INV. = 898.7
( TYP.) BOX
I '�0 281.0'
40.0':- I
I I
Ln
03.7 LO
I LOT # 18 0
r9 I
48,322 SF 0�
Y PVC _ ^
L1J \ i I I FORCE
L i I I MAIN
Q I
z i 1
-) I
i
1000 GAL.
I 111 i ( DOSING TANK
I 1250 GAL. 0 3.9
�-- O i I I SEPTIC TANK
d- j In
i In I
13.5'
In
p.aar
I
e'x,l
DE
TB M o °� ,OM 1:
41.8'
rU1� ms,
8 teas 9 5.13 I ,a.oa�
TC- 903.21 \
PER STM SEWER I /
A WWI FM
RECORD DRAWIN �% 1 896.8 rn
DATED 4/6/90 1 t, � g04.
04.6
II I N
I
a 50 BL
0
O p
ASSUMED NORTH
SCALE 1" = 30'
SEPTIC FIELD TO BE
FENCED OFF FROM CONSTRUCTION
TRAFFIC DURING CONSTRUCTION.
I Ijj 40'X35 I
I 1.0' w
N L &WME I 5
I i 02.8 F-
CWVE «j
II I , 3 S
4 I _ I �v w
�� - - `-i
I I HYDRANT 121.2 9 W 03"
a�
4'WALK /
W --
-� APRON
II 10'X25'
SIGN ESMT
AR R/W
V
NOTE: GARAGE F.F.E. IS
PROPOSED TO BE 7.6' ABOVE
T8M AT STM SWR STRUCTURE
OUTLET TO
ABSORPTION FIELD
DISTR%TI0N Box
2• PVC FORCE MAIN
FROM DOSING TANK
1 1" LONG RADIUS
9(r ELBOW
DISTRIBUTION BOX DETAIL
NOT TO SCALE
9
ELEV- 904.0
1 L:
CONTROLS AND AUDIO /VISUAL
ALARM TO BE LOCATED IN
DWELLING AS DIRECTED BY OWNER
48" PRECAST CONCRETE
ASTM C478 WITH .�
"0" -RING GASKET
ASTM C923
o.
a.
INFLUENT
ELEV
HIGH WATER ALARM `t
ELEV 900.2
PUMP ON
ELEV 899.9
DOSE VOLUME PUMP OFF v
GAL. ELEV
BOTTOM
ELEV 893.4
P1
1if
'® r .
GUIDE RAILS
80
z
TO DISTRIBUTION
BOXES i 40
- IN V- 901.2
O
BREAKAWAY
FLANGES
DOSING TANK & PUMP ( 1,000 Gal.)
(NOT TO SCALE)
SECURE GAS TIGHT
INSPECTION r/,�
\ PLUG VA MANHOLE
FINISHED GRADE
" MINIMUM
I ET ... f -
6 PVC LIQUID LEVEL MIN .15 "D"
SDR 35
3 "MINIMUM 6" MINIMUM
T- 2" I GAS
WALL
8'-12'
LIQUID DEPTH "D"
30" TO 78"
THICKNESS } REINFORCED DEFLECTION
CONCRETE BAFFLE
MINIMUM 2.5" t
t
BOTTOM THICKNESS
INSIDE LENGTH
4" TO 6"
�- OVTLET VC
SDR 35
2"
SEPTIC TANK (1,250 Gal.)
(NOT TO SCALE)
4%
EARTH FILL
BARRIER*
4" PVC ,:••;•"
SDR 35 • •; e'•
* BARRIER MATERIAL
SYNTHETIC FILTER FABRIC
FINISHED GRADE
-7
15"
EXIST.
BARRIER* / GRADE
;s
� e
e'•
O
. .•
•0.
,•.
CLEAN GRAVEL 36"
1/2- TO 2 1/2-
(WASHED L -ROCK)
SECTION OF ABSORBTION FIELD
EXISTING GRADE
o ° ,
•; o'• ° v BARRIER
e ° o
o'• °; e
°.�.
0
0
• ° ., 0 •.
CLEAN GRAVEL o ° ° •;
1/2" TO 2 1/2" ' . °
(WASHED L -ROCK) 'e000.
NOTE: � ° ,. 0 e
GRAVEL ENVELOPE AROUND THE .0 0 . 0 0
PERIMETER DRAIN SHALL EXTEND ° :.o o'•
WITHIN 6" OF THE EXISTING °
SURFACE. o'• °
e ° ••
• o
•o • o
e .• r
.. °°
to
.
. °°
0 • a
.°a••
4" PERFORATED PVC o'•
o•
NOTE: GLACIAL TILL LAYER n
SIDEWALK TO BE PLACED
V FROM PROPERTY LINE,
5' FROM BACK OF CURB,
PER PLAN.
00.0 PROPOSED GRADE
CONTOURS TAKEN FROM DEVELOPMENT PLAN
12"
NOTE:
BARRIER MATERIAL SHALL
BE SYNTHETIC FILTER FABRIC
1
42" MIN.
4 PERIMETER
DRAIN
I
tI�
PERIMETER DRAIN DETAIL
T 18"
4" I
20
0 0 20 40 60 80 100 120
U.S. GALLONS PER MINUTE
MODEL
TYPE
DISCH.
(in')
hp
CAPACITIES
SOLIDS
(inches)
GPM to
(feet)
HEADS to
(feet)
OSP33
Automatic and Manual
1 1/4
113
60
25
3/8
PUMP PERFORMANCE DATA
GroAy Sewer
PVC ASTM -D 2665 for 4-Indn and 6 -Inch pips only
ASTM -D 3033 SDR 35 for 4 -Inch pipe; SDR 41 for 6 -Inch through 15-hch pipe
ASTM -D 3034 SDR 35 for 4 -inch through 15-Inch pips
Pressure sewer, SDR 26, with compression Mthp for special crossing
conditions with potable water lines.
Force Male
Any PVC or AIRS pipe listed below for potable water or else PVC ASTM-D 1165
Schedule 40. 80. or 120
ConVessim fill" must be used In crossing situations with potable water
lines
Absorption Field Loterds
1. Sewer pipe listed above or potable water pips (at leod 4-Indnss In d rWer)
listed below, ss well as pipe meeting ASTM -D 2729 or ASTM FMO-U are
occeptable for absorption Field gravity lotuds.
2. The pipe must have perforations with the equivalent told opening as o cornparable
lie laid with 1/4-Inch open )Dints per foot of tie, with the following
provisions:
a. Three rove of holes
b. 112 -inch to 3/4 -inch dameter holss, with:
1/2 -inch holes at 2 1/4 inch. or closer spacing
5/8 -inch holes at 3 1/2 inch, or closer spacing
3/4-" Ades at 5 Inch, or closer spacing
c. Equal separation of rolie around the ckawnference.
3. The pipe must be delivered in stroight (uncoiled) kngths
Potable Water
The pipe must have the NSF (Notional Sanitation Foundation) sed far potable water
and be rated to withstand the applied pressure.
Solvent -weld fittings are not acceptable
POLYETHYLENE 160 p.s.L SDR 7 in 314 -inch, 1 -Inch and 1 1/4 -inch dameters only.
PVC ASTM -D 2241 SDR 13.5, 17, 21, or 26
ABS ASTM -D 1527 Schedule 40, 80
ASTM -D 2282 SDR 13.5. 17, 21, or 26
LIST OF ACCEPTABLE PLASTIC PIPE
NOTES
1. CONTRACTOR SHALL INSTALL A MINIMUM OF 2000 SQUARE FEET OF TRENCH BOTTOM
AREA OR 667 LINEAL FEET OF 3 -FOOT WIDE TRENCHES.
2. TRENCHES SHALL BE SPACED 7.5 FEET ON CENTERS AND INSTALLED PARALLEL TO
EXISTING SITE CONTOURS. TRENCHES SHALL BE INSTALLED LEVEL ALONG ENTIRE LENGTH.
3. THE TRENCH BOTTOM DEPTH MAY NOT EXCEED 18 INCHES BELOW EXISTING GRADE.
4. THE SITE OF THE PROPOSED ABSORPTION FIELD MUST BE PROTECTED FROM
COMPACTING, GRADING AND FILLING PRIOR TO SYSTEM INSTALLATION OR THE
SITE MAY BE RENDERED USELESS,
5. SEPTIC TANKS AND ABSORPTION FIELDS MAY BE CONSTRUCTED NO CLOSER THAN
5 FEET TO A PROPERTY LINE, OR CLOSER THAN 10 FEET TO A DWELLING OR OTHER
STRUCTURE. MAINTAIN A 50' SEPARATION FROM ANY PRIVATE WATER SUPPLY WELL
6. ALL OPENINGS AND SURFACES OF THE SEPTIC TANK SHALL BE SEALED TO PREVENT
GROUNDWATER LEAKAGE INTO THE SYSTEM.
7. THE 2" FORCE MAIN FROM THE DOSING TANK CONNECTING THE PUMP TO THE
DISTRIBUTION BOX SHALL BE ADEQUATELY BAFFLED OR AN ELBOW INSTALLED
IN THE DISTRIBUTION BOX TO PREVENT DIRECT DISCHARGE TO ANY OUTLETS WHICH
WOULD OVERLOAD INDIVIDUAL TRENCHES. UNPERFORATED 4" PIPING SHALL BE
INSTALLED FROM THE BOXES TO EACH TRENCH, AT WHICH POINT CONVENTIONAL
4' PERFORATED PIPING SHALL BE INSTALLED.
8. DOSING PUMP SHALL BE HYDROMATIC MODEL OSP33 OR EQUAL. PUMP SHALL
DELIVER 48 GPM 0 12 FT TDH.
9. NO TRAFFIC SHALL BE PERMITTED ON THE PROPOSED SEPTIC ABSORPTION FIELD
AREA.
10. ADDITIONAL SOIL COVER TO BE PLACED ABOVE EXISTING GRADE AFTER CONSTRUCTION
TO PROVIDE A MINIMUM OF 15" OF SOIL ABOVE THE FILTER FABRIC FOR FREEZE
PROTECTION.
11. CONSTRUCTION OF SEPTIC SYSTEM SHALL BE CONDUCTED ONLY WHEN SOILS ARE DRY.
12. ONLY TOPSOIL, NOT CLAY MATERIAL, SHALL BE PLACED OVER THE ABSORPTION
FIELD.
13. FINISH GRADE TO OBTANV POSITIVE SURFACE DROAGE AWAY FROM FIELD.
14. FOLLOWING INSTALLATION, BUT PRIOR TO BACKFL1ING OF SEPTIC FIELD
TRENCHES, HAMILTON COUNTY HEALTH DEPARTMENT SHALL BE NOTITD FOR
INSPECTION.
16. ALL CONSTRUCTION ACTIVITY ON THIS SITE SHALL BE PERFORMED IN COWUANCE
WITH APPLICABLE O.S.H.A. STANDARDS FOR WORKER SAFETY.
17. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO FIELD VERFY ALL
EXISTING UTILITIES AND CONDITIONS PERTANNING TO FNS PHASE OF WORK. THE
CONTRACTOR SHALL NOTY IN WRITING THE OWNER OR THE ENGWR OF ANY
CHANGES, OMISSIONS, OR ERRORS FOUND ON THESE PLANS OR IN FIELD BEFORE
WORK IS STARTED OR RESUMED.
mom MOM SAU
" DON'T
DIG
BLIND it
1= 800 -382 =5544
CALL TOLL FREE
1-800= 4284200
FOR CALLS OUTSIDE OF INDIANA
PER INDIANA STATE LAW IS -69 -1991.
IT IS AGAINST THE LAW TO EXCAVATE
WITHOUT NOTIFYING THE UNDERGROUND
LOCATION SERVICE TWO (2) WORKING
DAYS BEFORE COMMENCING WORK.
Revisions
010,
07
CERTM BY
TH6 OWNING AIO THE VM DESIGNS AND OOWVn C00M
NM ARE M DJ01W NTEIIECTM PROPERTY OF SOM
ENGw1FDtit10 OOIIPORArM AND ARE NOT TO aF USED OR REPA001
M MM OR N PART, 11 IT TIE TRIITIDI O3Wff OF SOME]
DIGIN ENIC cormTlol.
01996, Schneider Engineering Corporotiol
r Schneider
3020 North Post Road M*Merin
. Indianapolis, Indiana Surveying
46226 -0068 Landwape
317 - 888 -8282 GI3 w U3
317 - 899 -8010 Fax Geology
A ?"taw" 20" with li d&n. 11sysr. 01bees ! Asseektee,
DAVID VMACORTA
LOT # 18 LARKSPUR
HamUton County, Indiana
Septic System Design
Plot Plan
Date
Project No. Drs
A�
10/04/96
96- 1891 -14 BSC
Computer Files Sheet No.
� \14- 98\p11C:S \1800 \96189114.01NG