0773.97p
SLOPE PVC DUCT TO TEE FITTING ( SYSTEM b GO RISER £SUMP SCHEMATIC NO SCALE ALUMINUM G.O. FLOOR POUR CONCRETE FITTING AROUND 5A5E OF FLOOR FITTING 4 L FINISH FLOOR a 'a •.4 _ \� 1yO 'O O 000° o O \ \ e A H5 SADDLE O COMPACTED GRAN- ULAR FILL \ \ ° oO0oo0�0 0 0 � \ \ O _POUR CONCRETE AROUND PIPE SADDLE \\ \ a. \ \ d r . "�D 6' MIN P.V.G. 5CH 40 OR 60 CA,. PIPE "111\5.5. PIPE CLAMPS AiR FLOW — — (PITCH 1/8' PER FT J CO EXHAUST PORT DETAIL ROOF TOP UNIT SUPPLY DUCT ����■im!�;w RETURN AIR DUCT RETURN AIR GRILLE 4 RECTANGULAR TO ROUND TRANSITION RTU I £ 2 DETAIL SCALE: NO SCALE MECHAN I CAL NOTES ROOF TOP EQUIPMENT, VENTILATION EQUIPMENT GENERAL NOTES RTU I CARRIER MODEL 48DPO20 -5 208 -60 -3 142.5 FLA 7500 CFM @ 1.0" ESP NOM. COOL: 212,000 BTUH NOM. HTG: 115,000/270,000 BTUH (2 STAGE) (W/ ECONOMIZER HOOD E POWER EXHAUST) RTU 2 CARRIER MODEL 48DPO16 -5 208 -60 -3 !03.0 FLA 6000 CFM @ 1.0" ESP NOM. COOL: 178,000 BTUH NOM. HTG: ;:5,000/23!,000 BTUH (2 STAGE) (W/ ECONO" ! ZER HOOD E POWER EXHAUST) RTU 3 CARRIER MODEL 50HJ0053 208 -60 -3 21.9 FLA 1900 CFM @ 1.0" ESP NOM. COOL: 51,000 BTUH @ 95'F' DB OAT E 67° WB EAT (W/ ECONOMIZER) RTU 4 CARRIER MODEL 48HJD0053 208 -60 -3 21.9 FLA 1800 CFM @ 1.0" ESP NOM. COOL: 38,000 BTUH @ 95'F DB OAT E 67° WB EAT NOM. HTG: 59,000 BTUH (W/ ECONOMIZER) RTU 5E6 CARRIER MODEL 50H-j0073 208 -60 -3 33.3 FLA 2,400 CFM @ 1.0" ESP NOM. COOL: 58,400 BTUH @ 95°F DB OAT E 67' WB EAT (W/ ECONOM' ZER) RTU 7 GARRiER MODEL 48HJDO123 208 -60 -3 477 FLA 4800 CFM @ 0.6" ESP NOM. COOL: 106,500 BTUH @ 95'F DB OAT E 67° WB EAT NOM. HTG: 98,400/147,000 BTUH (2 STAGE) (W/ ECONOMIZER) NOTE: ALL ROOF TOP UNITS TO HAVE 4" ! N5ULATED ROOF CURB - FACTOR'.' ECONOM! ZER - UTILITY CONNECTION PACKAGE PROGRAMMABLE SET BACK THERMOSTAT - SOLID STATE ENTHALPY CONTROL - DIFFERENTIAL ENTHALPY CONTROL RADIANT HEATER SCHEDULE RH 1 -3,5,6 REVERBERAY MODEL DX40 -50N 20 -60 -1 1.1 FLA GAS INPUT: 50,000 BTUH W/ 40' TUBE E REFLECTOR RH 4 REVERBERAY MODEL DX50 -75N :20-60-1 1.1 FLA GA5 INPUT: 75,000 BTUH W/ 50' TUBE E REFLECTOR NOTE - ALL RADIANT TUBE HEATERS SHALL INCLUDE: - 120 /!© THERM057-AT5 - EXHAUST VENTED OUTSIDE THE BUILDING - FRESH AIR DUCT CONNECTED TO THE BURNER FOR CO'-III-BUSTION AIR - 24" LONG STAINLESS STEEL FLEXIBLE CONNECTOR W/ GAS COCK - HANGING CHAIN SET - NATURAL GAS ORIFACE - A.G.A. APPROVED - A BURNER HAVING DIRECT SPARK IGNITION, THREE (3) MONITORING LIGHTS, BURNER INSPECTION GLASS, AIR PRESSURE SWITCH FOR AIR FLOW SAFETY, AND A TWO YEAR WARRANTY - A COMBUST ON CHAMBER BEING 4 "DI A. x 10' LONG, 14 GAUGE ALUMINIZED STEEL W/ 10.52 SQUARE FEET OF RADIANT SURFACE AND A TWO YEAR WARRANTY - HEAT EXCHANGERS BEING 4 "DIA. x 10' LONG, 12 GAUGE BLACK STEEL WITH 10.52 SQUARE FEET OF RADIANT SURFACE AND A FIVE YEAR WARRANTY - 10' LONG HIGHLY POLISHED ALUMINUM REFLECTORS WITH A 91.7% REFLECT'VE EFFIC'ANCY AND 19.8 SQUARE FEET REFLECTIVE AREA - REFLECTORS CAPABLE OF ROTATING FROM 10 TO 45 AND ARE EASILY INSTALLED E REMOVED WITHOUT THE USE OF TOOLS ACCEPTED RADIANT HEATER MANUFACTURERS - 5OLARONI CS - GORDON RAY - CO -RAY VAG - RE- VERBER -RAY EF -3 PENN VENTILATOR MODEL LC20A BELT DRIVE, 660 RPM 120 -60 -1 1/3 HP 2075 CFM @ 0.375" SP W/ ROOF CURB TYPE RF BACKDRAFT DAMPER /DAMPER BOX VIBRATION ISOLATORS EF -4,5 PENN VENTILATOR MODEL LC20A BELT DRIVE, 795 RPM 120 -60 -1 1/2 HP 3000 CFM @ 0.375" SP W/ ROOF CURB 1 YPE RF BACKDRAFT DAMPER /DAMPER BOX VIBRATION ISOLATORS EF 1,2,6 PENN VENTILATOR MODEL ZT 120 -60 -1 0.4 FLA 88 CFM @ .125" SP co- I PENN VENTILATOR MODEL DI O- CW(UB)360 208 -60 -1 1 -1 /2 HP 1300 CFM @ 2.5" SP W/ - FAN VIBRATION ISOLATORS FLEXIBLE DUCT CONNECTIONS FAN HOUSING DRAIN 1/2" x 1 1/2" x 1/4" STEEL ANGLE MN-70. FRAME ACRYLIC EPDXY FINISH BELT DRIVE NOTE: CARBON MONOXIDE SYSTEM TO HAVE - UNDERGROUND PIPING TO BE SCH 40 PVC AND F77NGS SLOPED @ 1/8" PER FT. TO FAN RISER SEALED WATERTIGHT. - EXHAUST FAN BELT GUARD, VIBRATION ISOLATORS, BAKED -ON EPDXY FINISH, ACCESS DOOR, STEEL ANGLE IRON SUPPORT FRAME. - FLOOR EXHAUST F771N5: HARVEY #UF -HS -30 INCLUDING ALUMINUM FLOOR FITTING, PIPE SADDLE, 8' LONG 3" DIA. NEOPRENE HOSE, TAILPIPE ADAPTER, HOSE GUIDE UNIT /WALL/BASEBOARD HEATERS WH 1 Q -MARK MODEL CWH3208 208 -60 -1 2 KW 10.0 AMPS 6842 BTU /HR BUILT -IN T -5TAT DIFFUSER SCHEDULE Si METALA!RE SERIES 3000 ROUND ALUMINIUM DIFFUSER W/ D3 BALANCING DAMPER S2 METALAIRE SERIES V4000 30 "x8" SUPPLY GRILLE 53 METALAIRE SERIES V4000 8 "x4" SUPPLY GRILLE S4 METALAIRE SERIES 5000 24x24 LAY -IN PANEL DIFFUSER W/ ROUND NECK SAME SIZE AS CONNECTING DUCT, FOR T -BAR LAY -IN CEILING. 1) THIS WORK SHALL INCLUDE ALL HEATING, VENTILATING AND AIR CONDITIONING SYSTEMS REQUIRED AS INDICATED ON THE DRAWINGS, AND INCLUDES BUT IS NOT LIMITED TO HEATERS, FANS, FILTERS, CONTROLS, DUCTS, DAMPERS, GRILLES, REGISTERS, DIFFUSERS, DUCT INSULATION, AND ALL ITEMS REQUIRED FOR COMPLETE AND OPERABLE SYSTEMS. 2) EQUIPMENT SUPPLIED AND INSTALLED TO THE PROJECT SHALL BE OF THE MANUFACTURER AND CAPACITY AS NOTED ON THE PLANS (OR EQUAL SUBSTITUTIONS WITH PRIOR WRITTEN APPROVAL ONLY). THE MECHANICAL SYSTEM HAS BEEN DESIGNED AS A COMPLETE PACKAGE; MECHANICAL CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT, CONTROLS, AND MISC. ITEMS BE SUPPLIED TO PROVIDE A COMPLETE AND OPERABLE SYSTEM. 3) CONGEALED SUPPLY DUCTWORK TRUNKS SHALL BE SHEET METAL OF THE PROPER GAGE FOR THE DUCT SIZE AND AIR VOLUME HANDLED WITH 1/2" INTERIOR INSULATION, BRACED AS REQUIRED FOR THE DUCT SIZE AND AIR VOLUME HANDLED. EXPOSED SUPPLY DUCTWORK SHALL BE ROUND SHEET METAL, INTERNALLY INSULATED, PREFABRICATED WITH SPIRAL WELDED SEAMS, AND SHALL BE SIMILAR TO SPIROSAFE OR UNITED ALL FITTINGS, REDUCERS AND TRANSITIONS SHALL BE DUCT MANUFACTURER'S STANDARD FOR THE SYSTEM. SECONDARY SUPPLY DUCTWORK SHALL BE ROUND SHEET METAL, EXTERNALLY INSULATED, EXCEPT FOR THE LAST 5'- EACH DIFFUSER CONNECTION TO BE INSULATED METALLIC FLEXDUCT. ALL ROUND SECONDARY DUC75 TO BE SECURELY SUPPORTED WITHOUT SA65 OR KINKS, AND TO HAVE LOCKING QUADRANT DAMPERS AT MAIN TRUNK CONNECTION. 4) RETURN AIR DUCTWORK TRUNKS SHALL BE SHEET METAL OF THE PROPER GAGE FOR DUCT SIZE AND AIR VOLUME HANDLED WITH 1/2" INTERIOR INSULATION, BRACED AS REQUIRED FOR THE DUCT SIZE AND AIR VOLUME HANDLED. RETURN AIR TRUNK TO EXTEND MINIMUM OF 10' FROM UNIT CURB CONNECTION AS INDICATED. NOTE: ALL SYSTEMS ABOVE 2000 CFM SHALL HAVE RETURN AIR FIRESTATS AS REQUIRED PER STATE AND LOCAL CODES COMPLETELY INSTALLED AS A PART OF THIS WORK. ALL SYSTEMS SHALL BE COMPLETE WITH ALL FIRE DAMPERS AS REQUIRED PER STATE AND LOCAL CODES. 5) ALL DUCTWORK SHALL BE SECURELY HUNG AND FASTENED TO PRIMARY OR SECONDARY STRUCTURAL MEMBERS ONLY. 6) PROVIDE ALL NECESSARY ISOLATORS, CONNECTORS, DAMPERS AND VOLUME CONTROLS FOR A COMPLETE AND CONTROLLABLE MECHANICAL SYSTEM. 7) GRILLES AND DIFFUSERS SHALL BE AS NOTED ON THE PLANS (OR EQUAL SUBSTITUTIONS WITH PRIOR WRITTEN APPROVAL ONLY). PROVIDE ALL NECESSARY SPIN -INS, TAKE -OFFS, DAMPERS, SUPPORTS, CONNECTORS AND MISC. ITEMS FOR A COMPLETE INSTALLATION. 8) EXHAUST FANS SHALL BE AS NOTED ON THE PLANS (OR EQUAL SUBSTITUTIONS WITH PRIOR WRITTEN APPROVAL ONLY). PROVIDE ALL NECESSARY HOOD5, FLASHING, DAMPERS, CONTROLS, DUCTING, SUPPORTS, AND MISC. ITEMS FOR A COMPLETE INSTALLATION. 9) MECHANICAL CONTRACTOR SHALL BE FAMILIAR WITH THE WORK OF ALL TRADES AND VERIFY /COORDINATE HIS WORK WITH OTHER TRADES PRIOR TO THE BEGINNING OF WORK. 10) START -UP AND BALANCING SHALL BE COMPLETED IMMEDIATELY BEFORE OCCUPANCY OF THE FACILITY BY THE OWNER. A SIGNED COPY OF THE BALANCING REPORT SHALL BE DELIVERED TO THE OWNER UPON OCCUPANCY. i l) ALL ROOF TOP UNITS SHALL HAVE ECONOMIZERS SET TO 15% MINIMUM FRESH AIR INTAKE. 12) MECHANICAL CONTRACTOR SHALL INCLUDE ALL CONTROLS, CONDUIT AND CONTROL WIRING FOR ALL HVAG CONTROL SYSTEMS, 13) ALL REQUIRED PERMITS, LICENSES, INSPECTION AND TEST COSTS SHALL BE A PART OF THIS WORK. 14) ALL HEATING E COOLING SYSTEMS TO HAVE PROGRAMMABLE MICROELECTRONIC THERMOSTATS (EXCEPT RADIANT HEATERS) WITH ACCESS CODE AND FAN CONTROL FEATURE. 15) MECHANICAL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH ITS UNDERWRITERS LABRATORY LABEL, THE MANUFACTURERS' RECOMMENDATIONS, SPECIFICATIONS, AND GOOD ENGINEERING PRACTICES. 16) ALL. MECHANICAL EQUIPMENT SHALL BE OF AN APPROVED TYPE AND SHALL BE LABELED FOR USE IN THE AREAS PROPOSED FOR INSTALLATION. 0) C L' U, Q �lL W U. N W J :.i ci 0 1�11= 0 2 Z ui J J Lu O PROJ. NO. DRAWN BY= CHECKED B DATE: 3/ 1 REVISIONS+ Mir