HomeMy WebLinkAbout0729.97bCOMMUNITY GENTER%I/ \A
NOT IN CONTRACT
B2 1 M NEGH
EXISTING CANOPY
ABOVE) REMOVE
EXISTING E.I.F.S. E34 REMOVE EXISTING CE
AND SHEATHING CONCRETE PAVING
REMOVE EXISTING 5TUD FRAMING
AND STONE VENEER WALL
m
EXI5TINC5 GONG.
MASONRY WALL
TO REMAIN
REMOVE EXISTING
ALUMINUM STOREFRONT
SYSTEM
REMOVE EXISTING
ALUMINUM 5TOREFF
SYSTEM
REMOVE EXISTING
STUD FRAMING ANT
STONE VENEER WA
AEZ AE 1 I AF
(AG>
i
IIIIIIIIIIIIIEW
REMOVE EXISTING PILASTER,
COLUMN AND E.I.F.S. COLUMN
ENCLOSURE IN THEIR ENTIRIT'(.
12
Mal*
n-v
I
REMOVE EXISTING
STUD FRAMING AND
STONE VENEER WALL
REMOVE EXISTING
STONE VENEER
REMOVE EXISTING PILASTER,
COLUMN AND E.I.F.S. COLUMN
ENCLOSURE IN THEIR ENTIRITY.
REMOVE EXISTING CANOPY 5Y5TEM IN
ITS ENTIRITY. INGLUDIN6 STRUCTURAL
STEEL BEAMS, AND METAL 5TUD
FRAMING.
REMOVE EXISTING
CONCRETE SIDEWALK
REMOVE EXISTING
STUD FRAMING AND
STONE VENEER WALL
REMOVE EXISTING
E.I.F.5. COLUMN
ENCLOSURE
V tu
to
V
Z
1-
� O
IPEMOLITION PLAN - AREA Ila"
i
REMOVE EXIST Wzp ALUMINUM
STOREFRONT SYSTEM
REMOVE EXISTING
E.I.F.5. COLUMN
ENCL05LRE (TYP)
REMOVE EXISTING STUD; FRAMING
AND STONE VENEER WALL
REMOVE EXISTING ALUMINUM
STOREFRONT SYSTEM
EXISTING U
MA50NY WA
TO REMAIN
50ALE: 1 /5" = P -O"
LEGEND
EXISTING CONSTRUCTION TO REMAIN
— EXISTING CONSTRUCTION TO SE REMOVED
KEY' FLAN
NOT TO SGAL�
1�
; Qc :
No, -
=¢ :AR19400124 -<=
STATE ❑F
CHII T {EC�.�.
DRAWING REVIEW ISSUE
--i& ------------------------------------------------------------
a
BUILDING AGENCY SUBMITTAL
APRIL 15, 14x7
CONSTRUCTION BD /ISSUE
APRIL 15, IQG-7
REVISIONS
s— --------- - - - - -- - — - — — --
3
— ----------- -------------- - - - ---- - - - -- ------ ------ - - - - -- --- - - - ---
ZL4
FILE - DATE - TIM
461811Di1 0441m M06
PLAT SCALE DRAWN BY.
W - P-0' MCC
1
tr
i
i 1
DEMOLITION
PYCYY & IID39
D1.1
61�'
DEMOLITION NOTES
I.
CONTRACTOR SHALL INSPECT THE SITE AND EXISTING
CONDITIONS PRIOR TO THE COMMENCEMENT OF ANY
DEMOLITION WORK. ANY DISGREPENGIES WITH THE
EXI5TIN6 CONDITIONS AND THE DRAWING SHALL
BE COORDINATED WITH THE OWNER AND ARCHITECT
PRIOR TO THE START OF ANY WORK.
2.
COORDINATE WITH OWNER ANY EXISTING MATERIALS
OF ACCEPTABLE CONDITION WHICH ARE TO BE
SALVAGED AND STORED FOR P0551151-I= REUSE OR
SALE.
5.
DEMOLITION WORK SHALL NOT INTERFERE WITH
THE NORMAL OPERATION OF THE FACILITY OR WITH
NORMAL TRAFFIC FLOW. COORDINATE WITH THE
OWNER ANY POSSIBLE TIMES WHEN UNAVOIDABLE
INTERFERENCE OF NORMAL OPERATION5 WILL OCCUR.
4.
THE EXI5TIN6 E.I.F.S. AND IT5 STUD FRAMING
THRUOGHOUT THE EX15TING CANOPY SHALL BE
REMOVED IN ITS ENTIRITY. THE EXISTING
STRUCTURAL STEEL FRAMING SHALL REMAIN FOR
REUSE.
5.
THE EXISTING GONCRETE SIDEWALK PAVING
SHALL BE REMOVED IN ITS ENTIRITY.
6.
REMOVE EXISTING CANOPY LIGHT FIXTURE-5. RETAIN
PIG -TAILS FOR NEW LIGHTING FIXTURES TO BE
INSTALLED.
KEY' FLAN
NOT TO SGAL�
1�
; Qc :
No, -
=¢ :AR19400124 -<=
STATE ❑F
CHII T {EC�.�.
DRAWING REVIEW ISSUE
--i& ------------------------------------------------------------
a
BUILDING AGENCY SUBMITTAL
APRIL 15, 14x7
CONSTRUCTION BD /ISSUE
APRIL 15, IQG-7
REVISIONS
s— --------- - - - - -- - — - — — --
3
— ----------- -------------- - - - ---- - - - -- ------ ------ - - - - -- --- - - - ---
ZL4
FILE - DATE - TIM
461811Di1 0441m M06
PLAT SCALE DRAWN BY.
W - P-0' MCC
1
tr
i
i 1
DEMOLITION
PYCYY & IID39
D1.1
61�'