HomeMy WebLinkAbout0778.97aSUPERVISOR W O R K S H E E T
FOUNDATION CHECKLIST
BASEMENT
PROJECT INFORMATION
HOUSE NAME / ELEV.
SET NUMBER:
PLAN / JOB NUMBER
STANDARD OR REVERSED
- ANY NON -STD. CHANGES?
Q
U
FRONT OR SIDE LOAD
STD., ENLARGED, OR FULL BSMT.
(IN SET .) (OPT. 293) (OPT. 295)
ALL SIDING OR BRICK FRONT
(IN SET •) (OPT. 490)
BSMT. WINDOW OPT. QTY.
(MARK LOCATIONS) ON PRINT
FRONT PORCH WALL HT. TO BE
ABOVE TOP OF FTN. WALL
FLUSH W/ 9 1/4" lot FLR TJ.I.'s 2" ABOVE W/ 11 1/8" let FLR TJ.I.'s
FIREPLACE OPT.
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
BUILDING PERMIT NUMBER
LOT ADDRESS
TOWNSHIP
CHECKLIST
_.� SUMP PUMP LOCATION MARKED
SUMP PUMP SLEEVE LOCATION MARKED
MARK OUT ALL HAUNCHES NOT USED
MARK N FRONT PORCH WALL
IF NOT ON PRINTS
6" ABOVE W/ 14" lot FLR TJ.I.'s
MASONRY
PRE -FAB
SEWER AND WATER SLEEVE
LOCATIONS MARKED (3'W/ 4" SEWER
COUPLER 5' W/ 1 112" SLEEVE)
HIGHLIGHT ALL BEAM POC.K€TS
HIGHLIGHT ALL PAD FTG. LOCATIONS
SLAB
..PROJECT INFORMATION
HOUSE NAME / ELEV.
SET NUMBER
PLAN / JOB NUMBER
STANDARD OR REVERSED
ANY NON -STD. CHANGES?
FRONT OR SIDE LOAD
ALL SIDING OR BRICK FRONT
(IN SET 0) (OPT, 490)
MASONRY
FIREPLACE OPT. PRE -FAB
NOTE: INSTALL BRICK LEDGE ON MASONRY FIREPLACES
BUILDING PERMIT NUMBER
LOT ADDRESS
TOWNSHIP
CHECKLIST
MARK OUT ALL HAUNCHES NOT USED
MARK IN FRONT PORCH WALLS IF NOT ON PRINTS
WATER SLEEVE LOCATION MARKED
HIGHLIGHT ALL THICKENED SLAB FOOTINGS
— HIGHLIGHT ALL PAD FOOTING LOCATIONS
DO NOT REMOVE BLUEPRINTS FROM JOBSITE
1. EXCAVATOR PLACE PRINT TUBE INSIDE OF EXCAVATION.
2. WALL CONTRACTOR LEAVE ON TOP OF WALL.
3. PLUMBING CONTRACTOR LEAVE ON TOP OF WALL.
4. CONI$f�-'i'f C T(m LEAVE ON TOP OF WALL.
FRAME PUNCH -OUT CHECK LIST
1. GARAGE
GARAGE DOOR OPENING FRAMED TO CORRECT SIZE: 1' HT, 8' OR I6' WIDE.
GARAGE ATTIC ACCESS FRAMED TO CORRECT SIZE AND LOCATION
NAILERS AT ALL CORNERS OF GARAGE AND CEILING.
GARAGE STEP FRAMED AND KICK PLATE UNDER DOOR
BOW STUDS
STRAP ANCHOR NAILED CORRECTLY
2. HOUSE
CHECK FOR BOW STUDS
CHECK FOR NAILER5
MARK DOOR SWING DIRECTION AND 51ZE
CHECK FOR CASING ROOM (MIN 2" ON EACH SIDE)
CHECK GENTERLINE OF KITCHEN WINDOW `
CHECK BULKHEAD DIMENSIONS (2" LONGER AND 2" WIDER THAN CABINETS)
CHECK WALL SIZES IN RELATION TO CABINET SPACE
CHECK VANITY SIZES IN RELATION TO WALL SPACE
CHECK VANITY DEPTH TO DOOR OPENING (MIN. 24 1/2 ")
CHECK DOOR OPERATION AND INSTALLATION
CHECK WINDOW OPERATION AND INSTALLATION
CHECK BASEMENT STAIR AND 2nd FLOOR STAIR INSTALLATION
PITCH RAIL WALL INSTALLED 1/1" BELOW STRINGER AND 1 1/2m SHORT
HALF -WALL 42" FROM FLOOR AND SAME PITCH AS STAIRS (BOTH STAIRWAYS)
HALF -WALL AT STAIRS PAST STRINGER 11/2"
TUB PLATFORM BUILT CORRECTLY 16 1/2" HT., 39" X 51" IN51DE
NO STUDS • 24" O.G. AT CERAMIC AREAS. (I6" O.C. MAX-)
TUB BLOCKS INSTALL.=-D AT CERAMIC AREAS.
NAILER5 FOR FIBERGLASS TUBS INSTALLED
MEASURE VINYL AREAS FOR SQUARE
CB PANELS HAVE BLOCKS ON ENDS
CHECK FOR LOAD - BEARING POINTS IN HOUSE AND PROPER LOAD TRANSFER
STRAP ANCHORS SECURED IN HOUSE
GRAWL SPACE AND BASEMENT CLEANED OUT
STAIRWAY SHIMMED (MAX. 1/2" GAP EACH SIDE)
16t AND 2nd FLOORS LINE UP IN STAIR WELL
NO GAPS ABOVE STAIRWAY DRAFTSTOP
STAIRWAY DROP CEILING DONE CORRECTLY (CHECK PRINTS)
HANDRAIL BLOCKS N5TALLED 32" FROM STAIR NOSING
SAFETY BOOTS AND RAILS INSTALLED 3 1/2" FROM STRINGER
SQUASH BLOCKS INSTALLED PER PLAN AND TJ.1. DETAIL SHEET
FLOOR SHEATHING NAILED PER 5PEC.'s
FALL PROTECTION NSTALLED AT STAIR WALL OPENINGS
EYEBOLT AND ANCHOR POINT IN PLACE
ALL DRAFT STOP INSTALLED ON CHASE AND BAND JOISTS
_ ALL TYVECK STAPLED N -PLACE EXTERIOR
i
ALL HOLES PATCHED IN INSULATION BOARD
ALL TRIM INSTALLED PER PRINT
3 1/2" RIPS 1/2 SHEATHING INSTALLED ON CORNERS
ALL WINDOWS TAPED ON TOP AND GLUED ON FOUR SIDES
ALL DOORS TAPED ABOVE
PRINT HUNG ON NAIL N GARAGE
PERIMETER AND PANELS GLUED
INTERIOR WALLS GLUED DOWN
INTERIOR AND EXTERIOR WALLS NAILED INTO TRUSSES BELOW
SET TUBS INTO ROOM AND WIPE -OUT
ATTIC ACCESS INSTALLED IN HOUSE PER PRINT, 12" SIDES
ALL WINDOWS INSTALLED PER PRINT, ELEVATION AND STACK
JOIST HANGERS NAILED FRONT AND SIDES -
51TE PICKED UP AND PUT IN PILE EACH DAY
2X4 AROUND TOP OF CHIMNEY, 1 1/2" PA8T CHIMNEY FLAT
ALL GIRDER TRUSSES NAILED PER ENGINEERNG
REVISED 5/2/`36