HomeMy WebLinkAbout12120037bN
22' -0"
4' -6t-�z"
r�--------------------------------------------- --------- ---- - - -- -. -I
1
. p. �d p d � • p• �d p d � p• �d P d � p• �d
�
P
•v
1
1
0 1\7 - -- ----------------------------- --------------- ----- - - -- -*
\ �p 8" POURED CONCRETE ;
;
FOUNDATION WALL
CONSULT MECH,
`__ - - -- BREARING WALL
1
I
1
I I
1
I I
;
;
OPENING SIZE Af2
r---------------------- - -2X6 WOOD2EINC�WALL _ -J
I I
I I
•
I
1
; I
I I
i 1" WEATHER LIP
� I
I
_J - - -� -, -j- F -J - - - - - - -; - - -�
`I
I
UNEXCAVATED
�
I
I
I
I I I I I
Y
1
FOR PORCH STEPS 1 ,
! I I I I I I I I 11 I
I
C-+
'
U
r— — —
17-
— — — — — —
I •
1
— — —
— — — — — �
1
1
1
2X6 WOOD BEARING WALL
OVER 8°X 16" GONG FTC-
FL
W.H. I I I I I I I 1 I 1 1 1
I 1 I I I _ - - -1 I I I i 1
SP BEAM AS R49:D
_ SO
--
1 36
I
I
------------ - - - - -- _------- - - - - --
�-
I
-' GARAGE SLAB
--
_ 41-1-41-1- _ 1 _ _ _ _ _ _ 1 _ _ _ _
- - - -- - - - - -- -- - -i 1 't --
---- -
-- - - --- --- -1 - - --
---- _______ _- - — — — — —
TIO CANTILEVER FLOOR
4" AROUND
TYPICAL GARAGE FLOOR '
I
I I I
1
I
\ 4" CONCRETE SLAB c/w
FIBRE MESH REINFORCEMENT
ENTIRE FDN PERIMETER. SEE
\ (o mil POLY VAPOR BARRIER \
'
;
1 v ' COMPACTED GRANULAR FILL
N
—
1
o
'
8 "X 9' POURED CONCRETE
1 A 1
,
-----------------------------------------------------------
1 — — — v
I 14 IQ .v • v 4 Ia . v 4 pa •v
�v
1
1
T-- -------- -- - - - --- 27-11;------ - -
- -T+
FOUNDATION WALL
22' -0"
GENERAL FOUNDATION NOTES:
1) ALL SOIL IS BASED ON 2800 P.S,F,, AND CONCRETE IS BASED ON
2800 P.S.I. ID 28 DAYS, FOOTERS ARE loo" WIDE AND 8" DEEP
UNLESS NOTED OTHERWISE ON PLANS,
2) BASEMENT WALL HEIGHT SHALL BE S' OR AS NOTED ON PLANS, W/ SHORT
WALLS g CRAWL SPACE OR SLAB BELOW FROST LINE AS REQUIRED,
3) THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND JUDGE
FOR THEMSELVES, THE SUITABILITY OF THE PLANS IN RELATIONSHIP
TO THE BUILDING SITE, AND EXISTING GRADES.
4) THESE DRAWINGS SERVE AS A GUIDE TO THE CONSTRUCTION OF
THE BUILDING, DUE TO VARIATIONS IN DIFFERENT AREAS, THEY CAN
ONLY BE A GUIDE, AND IN NO WAY DICTATE ANY OF THE LOCAL
AND/ OR STATE BUILDING CODES, IT IS THE CONTRACTORS FULL
RESPONSIBILITY TO REVIEW ALL PLANS FOR ACCURACY AND
CLARITY, AND TO INSURE ALL SUBS ARE CLEAR AS TO THE SCOPE
OF THEIR WORK. THE CONTRACTOR ASSUMES ALL RESPONSIBILITY
FOR ERRORS IN DESIGN, DIMENSIONS OR OMISSIONS,
5) ALL STRUCTURAL MEMBERS ARE BASED ON AN ASSUMED NEED,
AND MAY CHANGE AT ANY TIME, IT IS THE CONTRACTORS
RESPONSIBILITY TO VERIFY ACTUAL NEED AND SIZES IF NOT SHOWN.
�o) ALL WINDOW SIZES LISTED ARE AS MANUFACTURED BY SEMCO
WOOD PRODUCTS, UNLESS NOTED OTHERWISE, AND MAY VARY
BASED ON SUPPLIER, ALL FINISHES AND ROUGH OPENINGS
MUST BE VERIFIED BY OWNER/ CONTRACTOR.
7) ALL DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION
OF THE CONTRACTOR IMMEDIATELY BEFORE CONSTRUCTION
IS TO RESUME, TO INSURE PROPER STEPS ARE TAKEN.
w
0
k
1 5-0"
! IJ
94' -0"
I
4' _6 y�" G _ 71,1 ° WITH CENTER DRAIN 2'- 1 2' -E5,
TILE TO PERIMETER DRAIN '
1
I
I
I
I
r-------------------------------------------------------------------------------------------------------------------------------------------------- - - - - -- - - - - --
m
24" DIA, X 36" D GONC,"
FTC, w /6X6 POST
W /SIMPSON TIE ANCHOR
(TYPICAU\ '
N
m
N
- -------------- - - - - --
1 1 PLUMBING FIXT ARE SHOWN
' I FOR APPROX REFERENCE.
I I
VERIFY LOCATION W /BUILDER
(:D 0
I
0 OR OWNER
SUMP SANITARY ; I ( I I FUTURE
I I II
i DEPRESS SLAB MIN, I" 1 - I BATHROOM
I�JI
� - - - -1- - - - - - - - - - -
L — — — — — — — — — -I r — —
vvvir��
II
II
II
II
II
II
2'-5" x
TYPICAL BASEMENT FLOOR:
4" CONCRETE SLAB c/W S
FIBRE MESH REINFORCEMENT
(o mil POLY VAPOR BARRIER S
COMPACTED GRANULAR FILL
1 -s'
' O
Sm
O
------- 4 - - - - -- -- - - - - -- � -- __ -_ -_- _ _- _ _-- - - -- -- - - - - 6 WD STUD - -- - - -T
2X
OUTLINE OF I I
MECH, CHASE I _
ABOVE 19 -3714 I c0
I I \,
I O
_
19 -1 l V4"
I
` - - -- J
CONSULT MECH,
`__ - - -- BREARING WALL
I
r�
CONTRACTOR FOR I
I I
;
;
OPENING SIZE Af2
r---------------------- - -2X6 WOOD2EINC�WALL _ -J
I I
1
STORAGE /MECHANICAL
1
; I
I I
FUTURE EXERCISE
_J - - -� -, -j- F -J - - - - - - -; - - -�
`I
I I
!�
'
n
I I I I I
Y
1
FOR PORCH STEPS 1 ,
! I I I I I I I I 11 I
I
C-+
'
U
r— — —
17-
— — — — — —
I •
1
— — —
— — — — — �
1
1
1
2X6 WOOD BEARING WALL
OVER 8°X 16" GONG FTC-
FL
W.H. I I I I I I I 1 I 1 1 1
I 1 I I I _ - - -1 I I I i 1
SP BEAM AS R49:D
_ SO
--
1 36
1
ID WD OR STL GOLUM�I (BEARING M
36 XI2 GONG PIER
I
------------ - - - - -- _------- - - - - --
�-
- --
--
_ 41-1-41-1- _ 1 _ _ _ _ _ _ 1 _ _ _ _
- - - -- - - - - -- -- - -i 1 't --
---- -
-- - - --- --- -1 - - --
---- _______ _- - — — — — —
I 1 MEET EGRE55 CODE I I 1 : r• .
5EG, R310 (TYPICAL) 1 I I x- 77777"777
I1 1 I r - - - - -- --------------------------
I 1 I I
---------- - - - - -1 1----- ---- - - - - -- -'
2B' -4" 1 14' -0"
FOUNDATION FLAN
1651 SQ, FT. BASEMENT AREA (INSIDE POURED WALLS)
1
t
4 2' -4
-f' -O
5' -81' 1 2' -0''
7' -8
cll
c+1
CV
61
r
N
O
O
N
lIl
cfl
U�
ZZ
�w
U
W
�> x .
O 7-t 3
�w
C
<un C n
a o
N �U
p� E c c
Uo< E
D
WO
W J 7-z
[✓ Q
U c
w
Wg E
C)o v
FOUNDATION PLAN
SITE PLAN
C
— —
----------------------------- - - - - --rr _- ----------------- - - - - -- -
II
------- 4 - - - - -- -- - - - - -- � -- __ -_ -_- _ _- _ _-- - - -- -- - - - - 6 WD STUD - -- - - -T
2X
U
r------------- - - -i�� =i�
1 1
I
` - - -- J
`__ - - -- BREARING WALL
I
r�
^VJ
;
;
-3'
;
PROVIDE CONIC FTG
M—I
n
1
FOR PORCH STEPS 1 ,
=lq
C-+
O
U
_ _ _ _ _ _
I •
1
' 1 I I
_ _ _ _
r — — — — — — — — — — -I r — —�J
i
1
1
I I I
I I I
1
I I I I
Lu
TIO CANTILEVER FLOOR
4" AROUND
1
I I I
I
ENTIRE FDN PERIMETER. SEE
'
I
N
TYPICAL WALL SECTION
--
I
8 "X 9' POURED CONCRETE
I
I
FOUNDATION WALL
I I I I _
U
O
ASPHALT DAMPPROOFING
I I I At
FUTURE FAMILY ROOM
Q
`•%�`',�
I
�
FDN INSULATION
}-
cQn
����
1
I I
II
I
II
u1
- -�
^
I I I I
T-111
-1
MEDIA WALL
�
i
-I I
u
B ,
I
24" DIA, X 36° D CONC.
FTG, w /6X6 POST
I
i
'
W /SIMP50N TIE ANCHOR I
I
FUTURE BEDROOM
II
I I
CONSULT STRUCTURAL ENGINEER
'
'
1
c
I 1 MEET EGRE55 CODE I I 1 : r• .
5EG, R310 (TYPICAL) 1 I I x- 77777"777
I1 1 I r - - - - -- --------------------------
I 1 I I
---------- - - - - -1 1----- ---- - - - - -- -'
2B' -4" 1 14' -0"
FOUNDATION FLAN
1651 SQ, FT. BASEMENT AREA (INSIDE POURED WALLS)
1
t
4 2' -4
-f' -O
5' -81' 1 2' -0''
7' -8
cll
c+1
CV
61
r
N
O
O
N
lIl
cfl
U�
ZZ
�w
U
W
�> x .
O 7-t 3
�w
C
<un C n
a o
N �U
p� E c c
Uo< E
D
WO
W J 7-z
[✓ Q
U c
w
Wg E
C)o v
FOUNDATION PLAN
SITE PLAN
C
U
r�
^VJ
M—I
n
C-+
O
U
0
Az
uj
U
VJ
VJ �n
�J
• N �
W M �
O
z°
0
CV
ODATE: March 30, 2012
DRAWN BY: M. Foerster
SCALE: 114" = 1' -0" Unless Noted
REVISIONS:
FOUNDATION REVISED -1 /1-1/2012
REVISED 9/1 7/12
SWEET
2 OF 5