HomeMy WebLinkAbout0383.97dI r _..T 4 I ,/1 .1" 1tl -A i /qu 151 -4 1/7" 81-011 5E60ND FLOOR PLAN -BRICK TO 5ELT 1/4" = 11-0" NOTES : I. ALL CASEP OPENINGS GREATER THAN 48" WIDE HOLD HEADER TIGHT TO PLATE 2. ALL 51-FOLO POORS R.0.'5 = 1 1/2" WIDER THAN POORS HEADER HT. = 82" AFF 3. ALL 131-PA55 POORS R.0.15 = SAME AS DOOR HEADER HT = 83" AFF 4. 2x BLOCKING UNDER ALL EXTERIOR 5W ING POORS 5. Ix BLOCKING UNDER ALL EXTERIOR SLIDING POORS 6. TOWEL BARS (TB) OVER CABINETS AND TOILETS BLOCK INC) TO BE 55" AFF TO CL 7. TOWEL BARS (TB) NOT OVER CABINETS AND TOILETS BLOCKING TO BE 39" AFF TO CL 8. BLOCKING FOR T155UE ROLPERS (TH) TO BE 24" AFF ALL EXTERIOR REAPERS TO BE 2-2x 12 OF U.N.O. . I NOTE : ALL DIMEN51ON5 ARE FROM FACE OF STUD TO FACE OF STUD. ALL 5TU05 ARE 3 1/2" UNLE55 NOTED. ALL 0IMEN510N5 PRESENTED HERE ARE FRAME DIMEN51ON5 ONLY - SEE BHT. 1.1 FOR FOUNDATION FOOTPRINT. ALL FIRST FLOOR WINDOW HOR. HT5 TO BE 7'-10° AFF +/ . VERIFY W/ ELEVATIONS AND CORNICE DETAILS NOTE, m ERRORS AND 0M1551ONS'WHICN MAY OCCUR IN THE CONTRACT DOCUMENTS SHALL M BROUGHT TO THE ATTENTION OF THE N ARCHITECT, IN WRITING, AND WRITTEN INSTRUCTION SHALL BE OBTAINED PRIOR TO PROCEEDING WITH CONSTRUCTION. THE CONTRACTOR SHALL BE HELD RE5P0N5181-E FOR ANY ERRORS, O15CREPANCIE5 OR OMISSIONS FOR WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR TO CONSTRUCTION AND /OR FABRICATION OF THE WORK. 0 Copyright 1990 Pulte Home Corporation G. M i6HAEL WAN60UR Architects / Consultants 1365 Shenandoah Rochester Hills Michigan 48306 Pv�.�rE 14fasterBuilder Project I N 9 1 A N A DIVISION 12220 North Meridian 5t. Suite 1165 Carmel, Indiana 46032 Subdivision / Plan PRINCETON Job No. PR T0M Date 15SUE 11/8/95 Sheet Title 5EG0NO FLOOR PLAN DR IGK TO BELT 2.3