LEAD WALL PAST
°>
N
OVER DIG
t—
3 -6AR 51PE ENTRY GARAGE
1/411 : 11.0"
C7
Ic
2-GAR SIDE ENTRY GARAGE
1/4" _ li3On
LEAD WALL PAST
OVER D16--
va
N
-
iI
I•
8
FA
551, �II
244" 161,gu 131.811
LEGEND
8" 8" WALL
8/4 8" WALL
4" LED6E
C, I L
o
8' I g o
1110
+
W8x18 TL BM Ll I — —
W d O y wO
w
OWE
�-
O W O
n
w
w
o 0
a�
o
vw
LEAD WALL PAST
°>
vsw
w
OVER DIG
t—
uYi
W/ 4x12 BRICK LE06E FOUNDATION LAYOUT
U3
w
cv
to
vob o
1(12
1101
8" POURED CONC WALL
III ° 8'-0" POURED HT ON
X III ° 8" x 20" CONT. 5PREAD
o
n1 M °o FOOTING
o —
cn
- - - POINT LOAD PG = POINT LOAD N PC T
P T I FROM A80VE FROM A60VE
KNEEWALL 32" ABOVE
TAIR TREAD NOSE
51-611 6° 41-011 51-9 3,4"
3' 011 13/4
TYP - - - - - - - - - - 3E POCKET
6"
6" WIDE, ,
--3-270- - - - - - - 511 DEEP
— _— 8" HIG
BLEEDER 1111111 1111 0 UP 13 R - 068 WALL O�NG -
L m 2'2x10 HOP 1
NO 5TL 13EAM
PIA. 5TL P05T ON
- - - - -- -
--- - - - - - - 30" x 30" x12" CONIC PADFT6
FAU 2x6 WALL ON 16" x 8' CONT.
- - p -2x12 5YP W/ CONIC THICKENED SLAB
2- 1/2" PLYWO FLITCHES
1 1 1 201'01/2111 1 1 1 1
201-11° 5 " 131-711
OUCH IN PIPE 5A5EMENT II
FOR RADON N EXHAUST �
W/ "T" BELOW SLAB 4" CONC, 5LA15 ON MIN
-0-
P _ 4" COMP. SAND FILL
M 8/4 0 Y
RDU6H IN I I/2' PIPE ° �o PC
t TO FLOOR DRAIN FOR o o v w
- - - - - - FAU CONDEN5ATE o ° ° >
III
i4 REBAR * 24" O. C., 7' LONG
TO SPAN OVER -016
UNEXCAVATED
4" CONC. 5LA13 W/
MIN. 4' GLEAN COMP. 5AND FILL
24" x 4" CONC .
RETURN — —
2'-4 1 /2u
FOUNDATION PLAN
1/411 s 11_011
161.311
211.011
O V
BLEEDER i 11 7 111
N� II N
341-111/2° X
1102
1120
— —8/4 — —
21.4 1/2"
34'-011
NOTE:
50ME COLUMN DIMENSION5 ARE FROM CENTER OF COLUMN
TO EXTERIOR FACE OF BASEMENT WALL.
NOTE
ERRORS AND OM1551ON5 WHICH MAY OCCUR IN THE CONTRACT
DOCUMENT5 SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT, IN WRITIN6, AND WRITTEN INSTRUCTION SHALL
BE OBTAINED PRIOR TO PROCEEDIN6 WITH CONSTRUCTION.
THE CONTRACTOR SHALL BE HELD RESPON515LE FOR ANY
ERRORS, DI5CREPANCIE5 OR OMISSIONS FOR WHICH THE
CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR
TO CONSTRUCTION AND /OR FABRICATION OF THE WORK.
� I O
3 j
3
v
uj
_ g
ED
BLEEDER �1 1 1111
- - SEWER
SLEEVE
N
co
cn �
8')
�o
ip
Icz
BLEEDER 1.1 1 11111
01 I I SUMP 411 x 4" CONC .
— 1 RETURN
I
WAT�jR AND 51 WER
ENTRANCE LCATION
NOTE
PROVIDE (2) '4 REBAR, TEN FT.
LON6 TO SPAN UTILITY TRENCH
O
a
VERIFY 5UMP
LOCATION W/
5UPERINTEN12ANT
0
NOTE:
FIELD VERIFY
UTILITY LOCATIONS
FOR SIDE OF HOUSE
W/ 5UPERINTENDANT
Field verify all dimensions
DO NOT SCALE DRA WINO
QC Copyright 1995 Pulte Home Corpor
LEAD WALL PAST
OVER DIG
8" POURED GONG WAL SEE ELEVATIONS FOR
uYi
W/ 4x12 BRICK LE06E FOUNDATION LAYOUT
U3
81-0' POURED HT ON IN TH15 AREA.
8" x 20" CONT. SPREAD
FOOTIN6
�/4
34'-011
NOTE:
50ME COLUMN DIMENSION5 ARE FROM CENTER OF COLUMN
TO EXTERIOR FACE OF BASEMENT WALL.
NOTE
ERRORS AND OM1551ON5 WHICH MAY OCCUR IN THE CONTRACT
DOCUMENT5 SHALL BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT, IN WRITIN6, AND WRITTEN INSTRUCTION SHALL
BE OBTAINED PRIOR TO PROCEEDIN6 WITH CONSTRUCTION.
THE CONTRACTOR SHALL BE HELD RESPON515LE FOR ANY
ERRORS, DI5CREPANCIE5 OR OMISSIONS FOR WHICH THE
CONTRACTOR FAILED TO NOTIFY THE ARCHITECT PRIOR
TO CONSTRUCTION AND /OR FABRICATION OF THE WORK.
� I O
3 j
3
v
uj
_ g
ED
BLEEDER �1 1 1111
- - SEWER
SLEEVE
N
co
cn �
8')
�o
ip
Icz
BLEEDER 1.1 1 11111
01 I I SUMP 411 x 4" CONC .
— 1 RETURN
I
WAT�jR AND 51 WER
ENTRANCE LCATION
NOTE
PROVIDE (2) '4 REBAR, TEN FT.
LON6 TO SPAN UTILITY TRENCH
O
a
VERIFY 5UMP
LOCATION W/
5UPERINTEN12ANT
0
NOTE:
FIELD VERIFY
UTILITY LOCATIONS
FOR SIDE OF HOUSE
W/ 5UPERINTENDANT
Field verify all dimensions
DO NOT SCALE DRA WINO
QC Copyright 1995 Pulte Home Corpor