HomeMy WebLinkAbout05040145 Resubmittal InfoRe.
s/permit.s/re-review ~bmittal form
$~2s.oo
Ochs, James A
From:
Sent:
To:
Subject:
Ochs, James A
Thursday, April 21,2005 9:50 AM
'brian@permereconstructionmanagement.com'
pool permit 05040145
PERMIT PLAN REVIEW STOPS
PAGE
PERMIT NUMBER: 05040145 - FRED & DEBRA FARRAH TYPE: RESPOOL
PARCEL ID : 1713030003003000
PARCEL ADDRS : 11085 QUEENS WY CIR CARMEL, IN 46032
APPLY DATE : 04 L8/0~ ISSUE DATE : i/O [ATE :
CONTRACTOR : PREMIER CONSTRUCTION MGNT
PHONE NUNBER : 317 213-8208 FAX NUMBER : 317 856-433C
REVIEW STOP: BLDG - BUILDING INSPECTOR REVIEW
REV NO: 1 STATUS: D DATE: 34/21/05 CONT ID:
REVIEW SENT BY: jochs DATE: 04/21/05 TIME: }9:42 TIME SPENT: }.00
REV RECEIVD BY: lochs DATE: 04/18/05 TIME: }9:41 SENT TO:
REVIEW NOTES: 2005-04-21 09:46:45 Plans lack requied information.
Residential Pool Plan Review Requirements
1. If an ~ fixture is provided, the pool diagram must indicate a Iow voltage or 120
vo t ght A 120 volt light must have an insulated #8 copper bond wire from light shell to an
approved light junction box.
2. Show the I(~cation of Ii ht fixture 'unction. box above the deck on site plan.
~ must show the location of pool pump, heater and filter.
4. ; location of a disconnect switch for pump, heater and pool cover.
Disconnect switches must be within sight and =< 50 feet from motor or must be the lock out
5. ~v location of ANY 120 volt electrical receptacles within 20 feet of pool. Include the
required GFCI receptacle within 20 feet but, no closer than 10 feet to the pools edge.
6. Show on site plan any lighting fixtures within 10 feet of pool (this includes Iow voltage
landscape fixtures).
7. Show location of pool cover keyed switch.
8. Show location of any electrical switches within 5 feet of pool.
9. Show dra!nage or drainage arrows on plot plan.
10. Provide side view drawing of pool including all depths and length of reach slope.
11. Show d ring board and/or slide on plot plar~, if none, state none.
12. Show figure 4 type handrail at all exits both ends of pool with auto cover.
13.
(ABOVE GROUND POOLS ONLY) State that a single twist lock receptacle will be used to
connect the pool pump motor to the electrical supply. Single receptacle must be GFCI
protected or, pump must be double insulated with an inter~al grou nd.
Bonding
Rebar of the shel deck rebar rebar must be tied with standard ties and
Pool frame and pane s needs ground rod type clamp, do not use water pipe clamp