HomeMy WebLinkAbout0499.97e(MATCH FOOTING REINF. iN
SiZE AND NUMBER REQ'D) - - - --
V
J - -FOOTiNG REINF. -
SEE PLAN
1
2
TYPICAL FOOTING STEP
SCALE: N " =1' -0" S401
CONCRETE WASH
6" DIA (NOM.) CONC
i FILLED STEEL POST
LINE OF CONCRETE
OR ASPHALT
i 800
j- - - - - -- __1_ _
c�
CONCRETE FOOTING
r,4
BOLLARD POST SECTION
SCALE: Y4 " =1' -0"
*4 HAIRPIN DETAIL
SCALE: -V4 " =1' -0"
(�JARORAIL -SEE ARCH.
W CHAMFER I GUARDRAIL WERT
PAVEMENT OR
GRADE - % T /WALL +(0' -0
Y2" EXP, JT. MATERIAt
-- SLAB W/(2) LAYERS OF W.W.F.
(4) #5 0 ±12" ELEV. VARIES
- GRANULAR FiLL
I.
- -- �'' - (4) 05
1' -6' 8" 1' -0"
3' -2"
RETAINING 'WALL DETAIL
SCALE: -Y4" =1' -0" S4(
NOTES:
1. REINFORCING SHOWN IS iN
ADDITION TO REINFORCING
SHOWN ON PLANS AND
SPECIAL DETAILS
2. REINFORCING TO MATCH
WALT REINFORCING INDICATED
INTERIOR OR EXTERIOR
LOAD-BEARING CMU
GROUT CORE
FULL HEIGHT - 8 "_
INTERIOR
NON- BEARING
CMU
WIRE MESH i
VERT WALL REINF WALL TIE _
A TYPICAL CORNER TYPICAL INTERSECTION
CMU WALL -
i r IT
VERT WALL REINF
C 1 TYPICAL,.JAMB
TYPICAL MASONRY 'WALL REINFORCING
SCALE: 1''-.-1' -0"
j �
tWr A �-
C8x11.5 W/10� " OX,
HEADED STUDS @
`f 24' 0;
RIGID INSULATION I •
SEE ARCH 12' CONC. WALL
2' -0 "ts r / EXP, JT. MAT'L
#5 ® 12" x r ..
SLAB -SEE PLAN
COMPACTED FILL
#5 0 12" E..W., E.F.
SEE PLAN AND SCHEDULE ' ' x T
FOR WALL FOOTING SIZE,
ELEVATION, AND REINFORCING
V
SECTION AT DOCK WALL
SCALE: T'4 " =1' -O" kS4
CENTERLINE OF FOOTING
BUILDING LiNE
STEEL COLUMN AND
,- - ,- ANCHORBOL T S-
I y SEE STAR BUILDING DWGS.
i
CMU /
HAIRPIN IN CENTER
$
i OF SLAB
W / 15 0 48 "0C
GRADE BEAM -
SEE PLAN a ; .;
_.
PIER-
SEE PLAN
FOOTING-
SEF PLAN ,
SECTION
MARK
SIZE
7
SCALE: -Y4"=1"-0"
5' -0" x 5' -•0" x 12"
5 - i5 E.W.
S4(
NOTES.
9 - #6 EX
P1229
T /SLAB, PIER
1. Work this detail with pre-
i
12" x 40"
OR FTG.
engineered building drawings
and S101.
2. See pre - engineered bldg.
j
drawings for number and
PL Y4 "x4x4
size of anchor bolts at
�3"
;3"
�_ W /NUT
each column.
- �► - --
_,,..__r_,
.Wo A307
1 "0 A36
1 WO A36
ANCHOR BOLT
ANCHOR BOLT
ANCHOR BOLT
TYPICAL ANCHOR BOLT DETAIL
k
FOUNDATION SCHEDULE
MARK
SIZE
REINFORCEMENT
F5.0
5' -0" x 5' -•0" x 12"
5 - i5 E.W.
F9.0
9' -0" x 9' -0" x 16"
9 - #6 EX
P1229
12" x 29"
-
FOUNDATION SCHEDULE NOTES:
1. Provide 3" concrete cover on bars.
2. Use concrete brick or CRSi Class 3, CHCP wire bar supports at 3' -0 ".
PIER SCHEDULE
MARK
SIZE
REINFORCEMENT
P1222
12" x 22"
4 - #f7 VERT.
P1224
12" x 24"
4 - #7 VERT.
P1229
12" x 29"
4 #7 VERT.
P1240
12" x 40"
4 - #7 VERT.
PIER SCHEDULE NOTES:
1. Provide 1 1/2" concrete cover over ties.
2. See typical pier elevation for tie and vertical bar- plccernent.
3. Provide L;RSI Typ. Bor Bend No. T5 ties for all veritcal ,`ace bars, if
there are more than four vertical bars in the pier.
;/ -- POUR SLAB, LEAVING OUT AREA
AROUND COLUMN. INFILL WITH CONCRE ill:
AFTER SLAB HAS CURED.
SLAB CONTROL JOINT-
TYPICAL AT ALL _
COLUMN LINES fit\ j/ `` - 1,`" EXPANSION JOINT MAIERiAL
�h
COLUMN ISOLATION JOINT
SCALE. NTS
VAPOR RETARDER - -._- FORMED KEY
COMPACTED, GRANULAR FILL
COMPACTED SUB - GRADE
TYPICAL SLAB CONSTRUCTION JOINT
SCALE: NTS
yb "x1" DEEP SAWN CONTROL JOINT,
ALL JOINTS SHALL BE SAWN WITHIN
VAPOR RETARDER - 12 HOURS OF' SLAB POUR.
COMPACTED, GRANULAR FILL °rte ?tI7Y 4 4 ;4t1
COMPACTED SUB-GRADE-
TYPICAL SLAB CONTROL JOINT
SCALE: NTS
L 'T '
rh
TYPICAL PIER
SCALE: W =1' -0„
DETAIL
-- - COLUMN -SEE PLAN
-- - ANCHOR BOLTS
WITHIN TIES
EE PLAN
SEE PLAN FOR LOCATION AND
ELEVATION. SEE PIER SCHEDULE
FOR REINFORCING.
-- - SEE PLAN FOR FTG.
GENERAL NOTES
G1. BUILDING CODES:
Uniform Building Code, 1991 with Indiana Hmendments
American Institute of Stee: Construction, I -RFD 2nd Edition
American Concrete Institute. 318-89
G2. DESIGN LOADS:
Roof Dead load: 25 psf
Roof Live Lood : 35 psf
Wind Load: Basic Speed = 75 mph, Exposure B
Seismic Load: Zone 1 Occupancy IV
G3. If Drawings and specifications are in conflict, the most stringent restrictions
and requirements shah govem.
G4. All contractors are required to coordinate their work with all disciplines to
avoid conflicts. The mechanical, electrical and plumbing aspects are not in the
scope of these drawings. Therefore, all required mafedals and work may not be indicated.
Locations, sizes and numbers of ail openings may not be completely indicated in the
§tructural darwings, the respectiw contractors shod verify there wcrk with all other
disciplines.
G5. Verify all existing conditions prior to any construction or fabrication. If different
than shown, notify engineer /'architect immediately for modification of drawings.
G6. The contract documents represent the finished structure. They do not indicaie
the method of construction, The contractor shall provide all measures necessary
to protect the structure during construction. Sucre measures shall include, but
not Ilmited to, bracing, shoring, underpinning, etc. McComas Engineering is not
responsible for the contractor's means, methods, techniques, sequences or
safety procedures during construction.
G7. Notes and details shall take precedence over general structural notes. Where no details
or sections are shown, construction shall conform to similar work on the project. Typical
sections and details may not be cut on the plans, but apply unless noted athervise.
G7. Provisions for future expansion:
Vertical: None
Horizontal: None .
SHALLOW FWNDATION AND SLAB ON MADE NOTES
SFI, Design Soii Bearing Pressure:
Spread Footings 2000 psf
Wail Footings 2000 psf
(Assumed UBC tabie 29 -B)
SF2. Soil to be stripped, compacteri and tested in accordance with the
recommendations of the soils engineer and project specifications.
SF3. Footings and slobs shall be placed of firm, undisturbed soil or on engineered fill.
Engineered fill shalf be compacted to a minimum dry density of 95% of
the Modified Proctor maximum dry density (ASTM-- D1557), placed in 6"
to 8" lifts. All interim slabs have a minimum of 6" of #53 Aggregate placed beneath them.
Pea gravel may not be used as on engineered fill. See soils investigation! report for further
recommendations.
SF4. Undercutting of the soil for foundation and /or slab placement may be required.
These drawings do not indicate the entire scope of undercutting, fill or Had soil removal
that may be required to attain the design sail bearing pressures. it is the responsiblity
of the contractor to obtain a soils investigation report, before bidding, to assess
the extent of excavation and compaction that may be required to meet the design,
criteria. The contractor shall retain the services of a soils engineer to monitor all
backfilling operations and to inspect footing bearing moterial, A report certified
by the soils engineer sholi be furnished to the architect /engineer verifying that all
foundations were placed on a material capable of sustaining the design bearing pressures.
SF5. if dewaiering is required, sumps shall not be placed within the foundation
excavation.
SF6 Maintain a maximum slope between adjacent footing bearing elevations of
2 horizontai to It vertical. Maintain a 2 horizontal to 1 vertical slope next to
existing foundations to avoid undermining foundations.
SF7, No horizontal joints are permitted in any foundation. Vertical joints are
permitted only in wall footings. j
DRED CONCRETE NOTES I
401 RC1 All concrete s#iall have the following 28 day compressive strengths:
LOCATION STRENGTH AIR ENTRAIN.
Wall Footings, Spread Footings, 3000 psi 11%
All concrete below frost line
Exterior Slabs, Piers, Wolls, Columns, 4000 psi 6%
Grade Beams, Concrete exposed to freeze /thaw
Interior Slabs 4000 psi fix
RC2. All reinforcing steel shall be detailed, supplied and placed in accordance
with ACI 315 -88, ACI 318 -89 and CRSI MSP - -90.
RC3. All reinforcing steel shod be shoo fabricated and, where applicable,
shall be wired together and conform to ASTM A - -615, Grade 60. i
RC4 Chomfer edges of exposed concrete 3/4', unless noted otherwise,
RC5. Contractor shall make four, 6"x12' test cylinders for each 50 cubic
yords of concrete poured for each days operation. Break 1 at 7 days,
2 at 28 days and retain spore.
2 RC6. All welded wire fabric shall conform to ASTM A185, FAmin.) of 65 ksi.
All welded wire fabric laps shall be 8 ".
40' RC7. All finished concrete, concrete formwork and falsework shah be =.r,
accordance with ACI 301 -89. Contractor is solely responsible for the �
design and constriction of oil formwork, folsework and shoring.
RC8, Provide the following coverages over reinforcir?9:
Footings: Bottom and Unfomned Edges 3' i
Formed Edges and Top 2'
Slab On Grade Welded Wire Fabric Upper Third
RC9. Provide sleeves for all openings in grade Teams, to totally separate
pipe from concrete.
MASONRY AND ROWORCED MASONRY NOTES
M1. Minimum 28 day compressive strength of concrete masonry units sholl be
2800 p.s.i. hosed on net area of the unit. Specified design compressive
strength of masonry sholl be fm = 2000 p.s.i. All units for exterior wails,
load - bearing walls and shear walls shall be normal weight block.
M2. All mortar shall be Type S. No admixtures may used unless approved by
3 architect /engineer.Mortar shall not be used for grouting cores or filling
bon d beans,
401 M3. ALL BLOCK SHALL BE LAID IN A RUNNING BOND PATTERN.
M4. Course grout shall be used were grouting is required. Slump shall be
$ +/- 1". Minimum grout compressive strength shall be 2500 p.s.i.
M5. All reinforcing shall be ASTM A615 Grade 60 (Fr-60 ksi).
Lap all reinforcing a minimum of 40 bar diameters.
M6. See architectural and specifications for ail control joint iocations.
Reinforcing in bond beams shall be discontinuous at control joints.
M7. Provide truss type horizontal 'pint reinforcement at 16° o.c. Side rods
and cross rods shall be #9 wire, galvanized, see specifications. Cut
pint reinforcement at control joints,
M8. Provide 'L' bas at all bond bean comers as required,
M9. Fill cores of block solid with grout two full courses below the bearing
of oil beans or lintels supported on masonry,
M10. All attachments to block shall be mode with Hilti HX 112" diameter x
3" sleeve anchors , unless noted otherwise. Anchors shall be installed per
manufacturer's recommendations.
M11. See typical schedules for masonry and steel lintels not indicated or plans, +
r
Y
i No.
80325 1t�=
S?aTE OF f `oz.
'i �
A
�vrY
1tl41St
FKU ND MGM
RAW alp [Fire
Lar ec.+U.E 414%dr -O
5 , s1aa1W
1�
if
W
0�
E-4
Q
4-•�1
(Do 4
>=
Z
cliID
ti
uc
I$
N
�L
i1
C.? ldN
tj &7, 1
���.
8Z BROAD RPNLF AMEN
PHONE OM 2MS-3475
PAX OM 2W7=1
SHF3ET lo.
84 00- 11