Loading...
HomeMy WebLinkAboutA1.2 REFLECTED CEILING_ELEC-DATA[1].pdfProject Number: Sheet Title: Issue Date: Sheet Number: Project: CA R M E L , I N D I A N A 4 6 0 3 2 By: Architect: Architecture / Project Management: Carmel, Indiana 46032 317.705.7980 (fax) 355 City Center Drive 317.705.7979 (phone) BO W E N & F L O O D , L L C / Drawn By Checked ByPrint Date Revisions: 76 0 3 R D A V E N U E S . W . PE D C O R S Q U A R E B U I L D I N G 2 CA R M E L S Y M P H O N Y N A1.2 REFLECTED CEILING/ELEC- DATA PLANS PEDCOR DESIGN GROUP, LLC 10/25/12 CONSTRUCTION DOCUMENTS THIS DOCUMENT IS AN INSTRUMENT OF SERVICE AND IS THE SOLE PROPERTY OF THE ARCHITECT AND PEDCOR DESIGN GROUP, LLC. ALL INFORMATION CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN, AND PEDCOR DESIGN GROUP, LLC. NO PART OR WHOLE OF THIS DESIGN, THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED, EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN GROUP, LLC. © COPYRIGHT 2012, JAMES R. STUTZMAN, AIA, CARMEL. 11/9/12 CHECK SET MC AJR 11/11/12 STATE RELEASE SET KEY PLAN SCALE: N.T.S. FIRST FLOOR EXISTING 2' X 2' FLUORESCENT FIXTURE TO REMAIN. CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO DESIGNER BEFORE PROCEEDING WITH CONSTRUCTION. HALLWAY LIGHTS TO BE TIED INTO THE EXISTING HALLWAY LIGHT CIRCUIT. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. GENERAL CEILING NOTES: EXISTING EMERGENCY LIGHT FIXTURE W/BATTERY PACK TO REMAIN. 5. 6. 4. 1. CP6 3. ADD A NEW HVAC UNIT DEDICATED TO THE VIDEO CONFERENCE ROOM AND KITCHEN. PATCH, REPAIR, AND/OR REPLACE CEILING GRID SYSTEM WHERE WALLS, LIGHT FIXTURES, OR PARTITIONS HAVE BEEN REMOVED. CEILING GRID SYSTEM TO BE RESTORED TO MATCH EXISTING ADJACENT CONDITION AS TO NOT SHOW LINE OF DEMOLITION. RELOCATED DOWNLIGHT FIXTURE. N INDICATION DUAL-LITE TO MATCH EXISTING. NEW OR RELOCATED CEILING MOUNTED EXIT LIGHT W/ DIRECTION DUAL-LITE TO REMAIN. EXISTING CEILING MOUNTED EXIT LIGHT W/ DIRECTION INDICATION N NL D 3 NIGHTLIGHT LOCATION. EXISTING. 2.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. ALL WALLS GO TO 6" ABOVE FINISHED CEILING UNLESS NOTED OTHERWISE. SEE CONSTRUCTION PLAN FOR OTHER WALL TYPE INFORMATION. CEILING HEIGHT IS 10'-0" A.F.F. UNLESS NOTED OTHERWISE. CEILING PLAN NOTES: CP1 CP2 INSTALL NEW TILE AND GRID AS SHOWN REUSE DEMO'D TILE AS MUCH AS POSSIBLE. PROVIDE NEW SWITCH TO CONTROL LIGHTING. CP3 CP4 LIGHT FIXTURES TO BE CONTROLLED BY AN OCCUPANCY SENSOR. REDISTRIBUTE HVAC FROM EXISTING UNITS. DEDICATE ONE EXISTING UNIT FOR BOWEN LAW AND THE OTHER EXISTING UNIT FOR CARMEL SYMPHONY. THREE-WAY SWITCH. DIMMER SWITCH. TWO WAY SWITCH. DENOTES NEW SWITCH LOCATION. EXISTING 2 X 4 LAY-IN GRID SUSPENSION SYSTEM. EXISTING 2 X 2 LAY-IN GRID SUSPENSION SYSTEM. EXISTING. REFLECTED CEILING LEGEND: NEW OR RELOCATED 2' X 4' FLUORESCENT FIXTURE TO MATCH EXISTING 2' X 4' FLUORESCENT FIXTURE TO REMAIN. CP5 NEW OR RELOCATED 2' X 2' FLUORESCENT FIXTURE TO MATCH REPLACE ANY DAMAGED OR MISSING CEILING TILES. NEW TILES TO MATCH EXISTING. G.C. TO VERIFY EXISTING GRID LAYOUT AND CONDITION. RE-USE EXISTING LIGHT FIXTURES WHERE SHOWN. STORE SALVAGED LIGHT FIXTURES DURING THE CONSTRUCTION PHASE. STORAGE OF SALVAGED FIXTURES TO BE COORDINATED WITH OWNER. FIXTURES TO BE CLEANED, RELAMPED, AND INSTALLED UPON COMPLETION OF CONSTRUCTION. EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG PLATE CONDITION. 10. 9. 8. 7. LOCATE NEW AND RELOCATED SMOKE DETECTORS DUE TO NEW WALL AND/OR LIGHT FIXTURE LAYOUT. INFORM DESIGNER AND DESIGN-BUILD CONTRACTOR OF CONFLICT FOR RECONFIGURATION OF DEVICE/S. PROVIDE TRANSITION FOR DIFFERENT GRID PATTERNS.CP7 N NEW OR RELOCATED EMERGENCY LIGHT FIXTURE W/BATTERY PACK TO MATCH EXISTING.N NEW OR RELOCATED LAY-IN GRID SUSPENSION SYSTEM TO MATCH EXISTING. NL CP4 N N N CP1 NL CP1 N CP4 N N ND N N N N N N N N N N N CP1 CP1 3 3 CP3 CP4 CP2 CP4CP2 CP4 CP2 CP4 N N N N CP2 N CP2 CP3 N N CP2 N CP1 CP2CP4 N CP1 CP7 CP1 CP5 CP3 CP5 CP2NL CP6 CP1 CP3 CP4CP3CP4CP3CP4 CP2 CP2 CP2 NL CP3 CP4 CP3 CP4 CP3 CP4 CP3 CP4 CP2 CP2 CP2 CP2 CP3 CP4 CP2 CP2 CP3 CP4 CP2 N CP3 N D N N N N N N F F F KITCHEN 126 IT STORAGE 124 CLOSET 103 RECEPTIONIST 102 FEC RECEPTION AREA 101 N CONFERENCE ROOM 109 N NN N N N SHARED OFFICE 104 PRIVATE OFFICE 107 PRIVATE OFFICE 106 HALLWAY 100 MUSIC LIBRARY/ COPY ROOM 121 COFFEE BAR 113 PRIVATE OFFICE 105 VIDEO CONFERENCE ROOM 123 PRIVATE OFFICE 116 PRIVATE OFFICE 117 PRIVATE OFFICE 118 PRIVATE OFFICE 108 CONF. ROOM 114 WORKSTATION 6'X9' PRIVATE OFFICE 115 SERVER CLOSET 122 COFFEE BAR 111 STORAGE CLOSET 119 +44" +44" +44" +44" EP8 EP3 N N N N N N N N N N N N N EP5 N N N N N N+44"+44" N N N NN N N N N N NN N N N N N N+44"+44" N N N N N N EP6 EP4 EP4 EP2 EP1 FEC FEC FE C HALLWAY 110 RECEPTION AREA 112 HALLWAY 120 HALLWAY 125 EP2 D EP2 +60" +60" N N +60" N +60" N +60" N +60" N GENERAL ELECTRICAL/DATA NOTES: ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY PEDCOR IT. ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION. ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED @ 18" AFF UNLESS NOTED OTHERWISE. 7. 8. 6. 5. 4. 3. PROVIDE FLOOR MOUNTED POWER/COMMUNICATIONS AS FLUSH MOUNTED. ELECTRICAL/DATA PLAN NOTES: FURNITURE SHOWN ON PLAN FOR REFERENCE ONLY.9. 10.PEDCOR IT TO PROVIDE PHONE AND INTERNET SERVICE. COPIER PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR COPY MACHINE. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP1 REFRIGERATOR PROVIDED AND INSTALLED BY TENANT. G.C. TO PROVIDE POWER SOURCE FOR REFRIGERATOR. VERIFY ELECTRICAL REQUIREMENTS WITH MANUFACTURER'S MANUAL. EP2 ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO BE COLOR WHITE. DUPLEX WALL OUTLET. DEDICATED CIRCUIT OUTLET.D CABLE TV OUTLET. FLOOR MOUNTED FLUSH MOUNT TELEPHONE OUTLET. ELECTRICAL/DATA LEGEND: GFI GROUND FAULT INTERRUPT CIRCUIT OUTLET. PHONE/DATA WALL OUTLET (BOX AND PULL STRING). +44" N HEIGHT AFF TO CENTER OF OUTLET MOUNTED VERTICALLY. DENOTES NEW OUTLET LOCATION. FLOOR MOUNTED FLUSH MOUNT DUPLEX OUTLET. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE BROUGHT TO THE ATTENTION OF THE DESIGNER BEFORE PROCEEDING. REFER TO MECHANICAL DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE PROCEEDING. 1. 2.ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS. CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS, ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO DESIGNER FOR REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW ONLY. PROVIDE A COVER PLATE ON EMPTY DUPLEX BOX.EP3 RELOCATE THERMOSTAT AS SHOWN.EP4 PROVIDE ELECTRICAL AND DATA FOR WALL MOUNTED TV MONITOR.EP5 TV MONITOR TO BE PROVIDED AND INSTALLED BY BOWEN LAW.EP6 NOT USED.EP7 RELOCATED WALL MOUNTED CAMERA AND SPEAKERS PEDCOR IT.EP8 SCALE: 1/8" = 1'-0" 1 REFLECTED CEILING PLAN A1.2 SCALE: 1/8" = 1'-0" 2 ELECTRICAL/DATA PLAN A1.2