HomeMy WebLinkAbout12.10.12 SL Merchant_s Square- Permit Issue Arch.pdfXXX
X
XXX
X
X
XXX
XXX
X
Detail Reference
Sheet Number
Elevation Reference
Drawing Number
Section Reference
Sheet Number
Door / Glazing
Opening Mark
Key Note
Grid Number
OFS OUTSIDE FACE OF STUDS
OH DR OVERHEAD DOOR
OPENINGOPNG
ORD OVERFLOW ROOF DRAIN
PAR
PARTIALPART
PCC PRECAST CONCRETE
PLASTIC LAMINATEPLAM
PLYWD PLYWOOD
PRCST PRECAST
PREFINISHPREFIN
PRELIM PRELIMINARY
PRKG PARKING
PAINT/PRESSURE TREATEDPT
PTD PAPER TOWEL DISPENSER
PTN PARTITION
QT QUARRY TILE
QTB QUARRY TILE BASE
R RADIUS/RISER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCING STEEL BARS
RECESSEDREC
REV REVISIONS / REVERSE
RM
ROW RIGHT OF WAY
RTU ROOF TOP UNIT
TD TRENCH DRAIN
TEL TELEPHONE
THRU THROUGH
TO TOP OF
TO FDN TOP OF FOUNDATION
TOP OF BEAMTOB
TOF TOP OF FLOOR/FOOTING
TOJ
TOM
TOP
TOS
TOT
TOW
TPD
TPH
TRTD TREATED
TOILET PAPER HOLDER
TOILET PAPER DISPENSER
TOP OF WALL
TOP OF TRUSS
TOP OF SLAB/STEEL
TOP OF PARAPET
TOP OF MASONRY
TOP OF JOIST
SUSPENDED CEILINGSUSP CLG
STRUCT STRUCTURAL
STANDARDSTD
SST STAINLESS STEEL
SPRINKLERSPKLR
SPEC SPECIFICATION
SOUND INSULATIONSND INS
SND SANITARY NAPKIN DISPENSER
SIMILARSIM
SHTHG SHEATHING
SQUARE FOOTSF
SEP SEPARATE
SECTIONSECT
SD SHOP DRAWINIGS/SOAP DISPENSER
SOLID CORE WOOD DOORSCWD
SCP SCUPPER
SCHEDULESCHED
ROOM
PARALLEL/PARAPET
TYP TYPICAL
UNLESS NOTED OTHERWISEUNO
UR URINAL
VANITYVAN
VAR VARIES
VINYL BASEVB
VCT VINYL COMPOSITION TILE
VERTICALVERT
VRFY VERIFY
VINYL WALL COVERINGVWC
W/WITH
WITHOUTW/O
WC WALL COVERING/WATER CLOSET
WD
WDW WINDOW
WOOD
Abbreviations used in referring to standards that apply
to the work include, but are not necessarily limited to,
the following:
AA Aluminum Associate, Inc.
AAMA Architectural Aluminum Manufacturer's Assoc.
American Concrete InstituteACI
AISC American Institute of Steel Construction
American National Standards InstituteANSI
ASTM American Society for Testing Materials
AWS American Welding Society
CRSI Concrete Reinforcing Steel Institute
National Association of Architectural Metal
Manufacturer's
NAAMM
NFPA National Fire Protection Association
X
DRAWING SCHEDULE
A0.0 PROJECT INFORMATION
A0.1 OPENING SCHEDULES
A2.1
TOILET ROOM PLAN, ELEVATIONS & ACCESSIBILITYA2.2
FINISH FLOOR PLAN
INTERIOR ELEVATIONS
A2.3
A4.1
A4.0
DOOR & SIDELIGHT ELEVATIONS & DETAILS
A0.2 FINISH SCHEDULES
A0.3 RESPONSIBILITY SCHEDULE
A1.0 DEMOLITION & FLOOR TRENCHING PLAN
FLOOR PLAN
ISSUED FOR PRELIMINARY REVIEW
ISSUED FOR PERMIT/CONSTRUCTION
ISSUED FOR REFERENCE ONLY
ISSUED FOR CONSTRUCTION W/ REVISED INFO.
CONSTRUCTION DETAILS
ARCHITECTURAL CASEWORK DETAILS
ARCHITECTURAL DETAILS
SPECIFICATIONS
FURNITURE PLAN
REFLECTED CEILING PLANA3.0
INTERIOR ELEVATIONS
A6.1
A6.2
A6.3
SP.1
SPECIFICATIONSSP.2
SPECIFICATIONSSP.3
CODE SYNOPSIS
GENERAL NOTES
1.THE COMPLETE CONSTRUCTION DOCUMENT SET IS INCLUSIVE OF THE DRAWING SHEETS LISTED IN THE DRAWINGSCHEDULE, THE INVITATION TO BID PACKAGE, AND ALL LANDLORD CONSTRUCTION REQUIREMENTS.
2.THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ANDSHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC., SHALL BEIMMEDIATELY REPORTED TO THE OWNER'S REPRESENTATIVE & ARCHITECT FOR CLARIFICATION PRIOR TO THEPERFORMANCE OF ANY WORK IN QUESTION. THE CONTRACTOR COMMENCING WORK ACCEPTS THE CONDITIONSOF THE PROJECT AND THE COMPLETENESS OF THE CONSTRUCTION DOCUMENTS. NO EXTRAS SHALL BE ALLOWEDFOR DISCREPANCIES AFTER THE WORK HAS BEGUN, EXCEPT WHERE THE CONDITION COULD NOT HAVE BEENDISCERNABLE WITHOUT THE REMOVAL OF THE CONCEALING CONDITION.
3.GENERAL CONTRACTOR AND ITS SUBCONTRACTORS (INCLUDING BUT NOT LIMITED TO HVAC, ELECTRICAL,PLUMBING, SPRINKLERS, ETC.) SHALL BE RESPONSIBLE FOR ALL PERMITS, INSPECTIONS AND ASSOCIATED FEES ASREQUIRED TO COMPLETE THE WORK.
4.ALL WORK SHALL BE IN COMPLIANCE WITH THE PROVISIONS OF THE 'AMERICANS WITH DISABILITIES ACT' (ADA)AND ICC/ANSI A117.1-2003.
5.WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT INCONTRACT, HE SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS.
6.THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIREPROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES.
7.DURING ALL PHASES OF WORK, DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ADJACENT ANDNEIGHBORING TENANTS. NOTIFY BY LETTER TO ADJACENT TENANTS OF ANYTHING THAT MAY HINDER THEIRBUSINESS OPERATIONS PRIOR TO START OF CONSTRUCTION.
8.'TYP.' SHOULD MEAN THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.UNLESS OTHERWISE NOTED, DETAILS ARE USUALLY KEYED & NOTED 'TYP.' ONLY ONCE WHEN THEY FIRST OCCUR.
9.DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. THECONTRACTOR SHALL ALERT THE ARCHITECT OF ANY GROSS INCONSISTENCIES BETWEEN SCALED DIMENSIONSAND WRITTEN DIMENSIONS.
10.ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS ANDNUMBER OF ITEMS PROVIDED. UPON DISCOVERY OF DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS ANDENGINEERING DRAWINGS, THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVEIMMEDIATELY.
11.HORIZONTAL DIMENSIONS ARE SHOWN FROM THE FINISHED FACE OF CONSTRUCTION, UNLESS NOTEDOTHERWISE.
12.VERTICAL DIMENSIONS ARE FROM THE TOP OF FLOOR FINISH, ESTABLISHED BY THE CONTRACTOR SUBJECT TOTHE APPROVAL OF THE OWNER OR ARCHITECT, UNLESS NOTED OTHERWISE.
13.DIMENSIONS ARE NOT ADJUSTABLE WITHOUT THE APPROVAL OF THE OWNER'S REPRESENTATIVE OR THEARCHITECT UNLESS NOTED +/-.
14.DO NOT SUBSTITUTE, REVISE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT OF THE OWNER'SPROJECT REPRESENTATIVE.
15.COORDINATE ALL WORK AS REQUIRED WITH THE LANDLORD'S REPRESENTATIVE INCLUDING COMPLIANCE WITH"LANDLORDS WORKING RULES", LOCAL NOISE ORDINANCES, THE USE OF ELEVATORS, TEMPORARY STORAGE,LOADING DOCKS, BUILDING KEYING SYSTEMS, ETC. PROVIDE NECESSARY BARRICADES, LIGHTING, SIGNAGE, ANDGUARDRAILS AS REQUIRED BY OWNER AND/OR APPLICABLE REGULATORY ADVISORY FOR THE PROTECTION OFBUILDING OCCUPANTS, WORKERS AND PEDESTRIANS.
16.GENERAL CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING,RESTORING, REPAIRING AND THE LIKE NECESSARY TO COMPLETE THE WORK AND RESTORE ANY DAMAGEDSURFACES RESULTING FROM THE WORK TO THEIR ORIGINAL CONDITION. ALL ROOF PATCHING SHALL RETURNAREA TO "LIKE NEW" CONDITION. PRIOR TO BIDDING, G.C. TO VERIFY ANY ROOF WARRANTIES WITH LANDLORDAND INCLUDE IN CONTRACT. G.C. TO COORDINATE ALL MEANS AND METHODS OF DEMOLITION, SAW CUTTING,CORING AND PATCHING LANDLORD CONSTRUCTION AND MATERIALS WITH LANDLORD PRIOR TO CONSTRUCTION.
17.IN THE EVENT HAZARDOUS MATERIALS ARE ENCOUNTERED ON THE PREMISES DURING THE EXECUTION OF THEWORK, NOTIFY THE OWNER'S REPRESENTATIVE & LANDLORD IMMEDIATELY BEFORE PROCEEDING WITH WORK.
18.CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A/10BCWITHIN 75' TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING DURING CONSTRUCTION.
19.PATCH AND REPAIR ALL FIREPROOFING DAMAGED OR REMOVED DURING THE PERFORMANCE OF THE WORK.
20.EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETIONOF HIS WORK ON A DAILY BASIS. ALL WASTE, RUBBISH AND EXCESS MATERIALS SHALL BE REMOVED FROM THESITE PROMPTLY. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL & DISPOSAL OF ALL TRASH,INCLUDING OWNER-FURNISHED ITEMS & TRASH GENERATED BY OWNER'S CONTRACTORS FOR THE DURATION OFTHE PROJECT.
21.IT IS THE RESPONSIBILITY OF THE G.C. TO OBTAIN LANDLORD/CITY APPROVED DRAWINGS PRIOR TOCONSTRUCTION. LANDLORD/CITY APPROVED DRAWINGS SHALL BE RECEIVED FULLY BY THE G.C. PRIOR TOCONSTRUCTION AND ANY PROVISIONS, ADJUSTMENTS OR MODIFICATIONS AS REQ'D. BY LANDLORD/CITY SHALLBE COORDINATED WITH THE TENANT/LANDLORD/CITY PRIOR TO CONSTRUCTION IF NOT CLEARLY INDICATED INTHE CONSTRUCTION DRAWINGS. LANDLORD/CITY APPROVED DRAWINGS SHALL BE AVAILABLE ON SITE FROMSTART OF CONSTRUCTION TO COMPLETION AND FINAL PUNCH.
22.THE CONTRACTOR WILL OBTAIN A CURRENT COPY OF THE LANDLORD CONSTRUCTION CRITERIA FROM THELANDLORD & COORDINATE WITH LANDLORD FOR USE OF ALL REQUIRED SUBCONTRACTORS AND CONSULTANTS.
23.CONTRACTOR TO VERIFY INTEGRITY OF EXISTING CONDITIONS, INCLUDING ALL STRUCTURAL ELEMENTS, AFTERCOMPLETION OF DEMOLITION AND NOTIFY THE OWNER'S AND LANDLORD'S REPRESENTATIVES IMMEDIATELY OFANY DAMAGES AND/OR INSTABILITY.
24.GENERAL CONTRACTOR SHALL INSPECT ALL LANDLORD'S WORK TO ENSURE COMPLIANCE WITH LANDLORDSWORK LETTER AND SHEET A1.0 OF THIS DOCUMENT SET. ALL LANDLORDS WORK SHALL BE IN FULL CODECOMPLIANCE AND GOOD WORKMAN LIKE ORDER - GENERAL CONTRACTOR SHALL ACCEPT RESPONSIBILITY FORALL WORK AT TIME OF LANDLORD TURN OVER FOR TENANT'S CONSTRUCTION.
25.SAFETY MEASURES: AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THECONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF THE PERSONS AND PROPERTY AND FOR ALL INDEPENDENTENGINEERING REVIEWS OF THESE CONDITIONS. THE ARCHITECT'S, ENGINEER'S AND/OR TENANT'S JOB SITEREVIEW IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES.26.ALL DRILLING, WELDING, OR OTHER ATTACHMENT TO THE STRUCTURAL SYSTEM MUST BE APPROVED BY THELANDLORD IN WRITING BEFORE WORK IS BEGUN. THE CONTRACTOR TO COORDINATE WITH LANDLORD.
27.ADEQUATE FIRE RETARDANT BLOCKING, BRACING, BACKING AND/OR ADDITIONAL STUDS MUST BE PROVIDED BYTHE CONTRACTOR TO SUPPORT ANY STORE FIXTURES, SHELVES, MILLWORK, OR DECORATIVE ELEMENTS, TRIMFASTENED TO THE WALLS. THE CONTRACTOR TO COORDINATE WITH FIXTURE SUPPLIER AS NECESSARY.
28.THE USE OF WOOD OR OTHER COMBUSTIBLE MATERIALS ABOVE THE CEILING IS PROHIBITED, UNLESS NOTEDOTHERWISE.
29.GENERAL CONTRACTOR SHALL HAVE OBTAINED ALL REGULAR INSPECTIONS WITH AT LEAST A TEMPORARY'CERTIFICATE OF OCCUPANCY' IN POSSESSION PRIOR TO THE CONSTRUCTION PUNCH DATE.
30.GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO HAVE THE ENTIRE PROJECT AREA FINAL CLEANED (SPOTLESS)AT THE TIME OF TURNOVER TO THE OWNER.
ABBRV TERM ABBRV TERM
ACC ACCESSIBLE
ACOUSTICAL CEILING TILEACT
ADA AMERICANS WITH DISABILITIES ACT
ADDITIONALADDL
ADDM ADDENDUM
ADJACENTADJ
AFF ABOVE FINISHED FLOOR
ALTERNATE
ALUMINUMALUM
ALT
BLDG BUILDING
BITUMINOUSBITUM
BRG BEARING
BASEMENTBSMT
BTWN BETWEEN
CABINETCAB
CL CENTER LINE
CLASS CLASSIFICATION
CLG CEILING
CLG HT CEILING HEIGHT
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL
CONC
CONSTR
COORD COORDINATE
CONSTRUCTION
CONCRETE
COLUMN
CPT CARPET
CERAMIC TILECT
DEMOLITIONDEMO
DET DETAIL
DRINKING FOUNTAINDF
DIA DIAMETER
DIMENSIONDIM
DIR DIRECTION
DOORDR
DS DOWNSPOUT
DISHWASHERDW
EA EACH
EXTERIOR INSULATION AND FINISH SYSTEMEIFS
EXPANSION JOINT
ELEVATIONEL
EJ
ELEV ELEVATOR
EQUALEQ
EQUIP
ESMT EASEMENT
EQUIPMENT
EXIST EXISTING
FACE BRICKFC BRK
FD FLOOR DRAIN
FDTN FOUNDATION
FF EL FINISH FLOOR ELEVATION
FINISHFIN
FIN FLR FINISH FLOOR
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FIBERGLASS REINFORCED PLASTICFRP
FT FEET
FOOTINGFTG
FURG FURRING
GALVANIZEDGALV
GB GRAB BAR
GENERAL CONTRACTORGC
GL GLASS
GLZ GLAZING
GYP BD GYPSUM BOARD
HC HANDICAP/HOLLOW CORE
HOLLOW CORE WOOD DOORHCWD
HDW HARDWARE
HOLLOW METAL DOOR AND FRAMEHMDF
HT HEIGHT
HEATING, VENTILATING, & AIR CONDITIONINGHVAC
ID INSIDE DIAMETER/INSIDE DIMENSION
INSUL
INT INTERIOR
INSULATION
LAMINATE
ANGLEL
LAM
LAVATORYLAV
LDG LANDING
LTG LIGHTING
MATL MATERIAL
MFR MANUFACTURER
MFR RECMANUFACTURER'S RECOMMENDATION
MIN MINIMUM
MASONRY OPENINGMO
MTL METAL
NUMBERNO
NTS NOT TO SCALE
ON CENTEROC
OD OUTSIDE DIAMETER/OUTSIDE DIMENSION
ABBREVIATIONS
SYMBOLS
Datum Point
XXX Owner Supplied
Item Tag
X Revision Number
XXX Finish Key
X
X
ABBRV TERM
A2.0
A2.4
DIMENSION FLOOR PLAN
A6.0
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
SALON LOFTS
PROJECT TEAM
FINN DANIELS ARCHITECTS
2145 FORD PARKWAY, SUITE 301
ST. PAUL, MINNESOTA 55116
651.690.5525 (VOICE)
651.690.5545 (FACSIMILE)
CONTACT: SCOTT WIESTLING
EMAIL: swiestling@finn-daniels.com
SALON LOFTS
100 SOUTH 4TH STREET #100
COLUMBUS, OHIO 43215
614.227.0530 (VOICE)
614.227.3280 (FACSIMILE)
CONTACT: TANAYA CANDELLA
EMAIL: tcandella@salonloftscorp.com
TENANT:
ARCHITECT:
RAMCO-GERSHENSON PROPERTIES
31500 NORTHWESTERN HIGHWAY #300
FARMINGTON HILLS, MICHIGAN 48334
614.481.0353 (VOICE)
CONTACT: GILLI ZOFAN
EMAIL: gzofan@rgpt.com
BUILDING
OWNER /
LANDLORD:
BUILDING/
ZONING
DEPTS.:
EMANUELSON-PODAS, INC.
10401 BREN ROAD EAST
MINNETONKA, MINNESOTA 55343
952.930.0050 (VOICE)
952.930.0777 (FACSIMILE)
CONTACT: MATT COLEMAN
EMAIL: mcoleman@epinc.net
MEP
ENGINEER:
VICINITY MAP
N
BUILDING KEY PLAN
N
CITY OF CARMEL
1 CIVIC SQUARE
CARMEL, INDIANA 46032
317.571.2400 (VOICE)
ARCHITECTURAL
E1.1 LIGHTING PLAN
ELECTRICAL
E2.1 POWER PLAN
E3.1
E4.1 ELECTRICAL SPECIFICATIONS
M1.1 MECHANICAL PLAN
MECHANICAL
M2.1 PLUMBING PLAN - SANITARY & VENT
M2.2 PLUMBING PLAN - DOMESTIC WATER
M3.1 PLUMBING RISER DIAGRAMS
M4.1 MECHANICAL DETAILS AND SCHEDULES
M5.1 MECHANICAL NOTES
M5.2 MECHANICAL SPECIFICATIONS
12
.
0
7
.
1
2
CL
I
E
N
T
R
E
V
I
E
W
SE
T
SALON LOFTS
MERCHANT'S SQUARE
4,906 SQUARE FEET
12
.
1
0
.
1
2
PE
R
M
I
T
I
S
S
U
E
A1.1 BUILDING SHELL MODIFICATIONS PLAN & DETAILS
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
PROJECT INFORMATION
A0.0
A1.2 EXTERIOR ELEVATIONS
ELECTRICAL SCHEDULES AND RISER
ARCHITECTURAL DETAILSA6.4
SMITH/ROBERTS & ASSOCIATES, INC.
6501 BLUFF ROAD
INDIANAPOLIS, INDIANA 46217
317.951.1043 (VOICE)
317.951.2160 (FACSIMILE)
CONTACT: JEFF LUNSFORD
EMAIL: jlunsford@sraeng.com
STRUCTURAL
ENGINEER:
S1.0
STRUCTURAL
STRUCTURAL PLAN & DETAILS
Required Provided
PLUMBING FIXTURES:
A.NUMBER FIXTURES REQUIRED (IBC 2902.1)
Based on 50 Occupants - B Occupancy
- 25 Female Occupants
- 25 Male Occupants
(a) BOTTLED WATER SHALL BE PROVIDED IN EACH LOFT FOR EMPLOYEES AND CUSTOMERS.
Fixture
Water Closets (1 Per 25 Occupants)
Lavatories (1 Per 40 Occupants)
Drinking Fountain (1 Per 100 Occupants)
Service Sink
Men Women
1 1
1 1
1 1
1 1(a)
SIGNAGE:
A.SIGNAGE IS NOT WITHIN THE SCOPE OF THIS PERMIT. SUBMIT DRAWINGS TO LOCAL JURISDICTION FOR
REVIEW AND APPROVAL IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES PRIOR TO INSTALLATION.
A.BUILDING OCCUPANCY USE GROUP: B - BUSINESS
B.BUILDING CONSTRUCTION TYPE: TYPE II-B (EXISTING)
C.SALON LOFTS OCCUPANT LOAD: 50 (BASED ON 1 OCC. PER 100 S.F. @ 4,906 S.F.)
D.QUANTITY OF EXITS REQUIRED: 2
E.QUANTITY OF EXITS PROVIDED: 2
F.SPRINKLER SYSTEM: NO
G.FIRE ALARM SYSTEM REQUIRED: NO (PER IBC 907.2.2 FOR GROUP B OCC. < 300 OCC.)
H.SEISMIC ZONE: N/A
A.INDIANA BUILDING CODE (IBC)2008
B.INDIANA FIRE CODE (IFC)2008
C.INDIANA MECHANICAL CODE (IMC)2008
D.INDIANA PLUMBING CODE (IPC)1999
E.INDIANA ELECTRICAL CODE (IEC)2009
F.ICC A117.1 ACCESSIBLE & USABLE BUILDINGS & FACILITIES 2003
G.CITY OF CARMEL CODE CURRENT
APPLICABLE CODES:
BUILDING CLASSIFICATION:
Men Women
1 1
1 1
A4.2 INTERIOR ELEVATIONS
HOLLOW METAL
(1 1/4" NARROW
PROFILE FRAMES)
PAINT
8'
-
0
"
DO
O
R
1 1/4"
1
1
/
4
"
3'-0"
DOOR
3
P7
3'-1 1/2"
R.O.
8'
-
0
3
/
4
"
R.
O
.
FLUSH DOOR (SWING)CS.C. WOOD (STAIN/SEAL)
PLAIN SLICED RED OAK W/
CUSTOM STAIN TO MATCH
W/ GLASS PANEL
1/4" TEMP.
CLEAR
GLAZING
10
"
6"
6"6"
DFLUSH DOOR (SWING)
S.C. WOOD (STAIN/SEAL)
PLAIN SLICED RED OAK W/
CUSTOM STAIN TO MATCH
A6.0
9sim
2'
-
0
"
3'
-
7
"
5" SOLID TOP
RAIL
LOCK BLOCK
FOR DOOR
HANDLE
5" SOLID
BOTTOM RAIL
FLUSH DOOR (SLIDING)
H.C. WOOD (STAIN/SEAL)
PLAIN SLICED RED OAK W/
CUSTOM STAIN TO MATCH
A B
PL-4 PL-4 PL-4
2 ALUM. GLAZING SYSTEM
2" x 4 1/2" CLEAR ANODIZED
ALUMINUM FRAME W/
1/4" CLEAR TEMP. GLAZING
8'
-
2
"
7'
-
1
0
"
2"
2"
6'-0"± R.O.
(VERIFY)
3'-0"
DOOR
1'-6"
2"2"
1'-6"
W-1 1 3/4" x 4 1/2" DARK BRONZE
ANODIZED ALUM. FRAME W/
1/8" TEMPERED TINTED SAFETY
GLAZING TO MATCH EXISTING
ALUM. GLAZING SYSTEM
CAT 5/6 CABLE
PoE SWITCH OR
MIDSPAN
INJECTOR
POWERED
ELECTRIC
LOCK
FIRE
ALARM
SYSTEM
RELAY
WIEGAND
OR PIN
CARD
READER
18 AWG 2 COND.
18 AWG 6 COND.
WIEGAND
OR PIN
CARD
READER
18 AWG 6 COND.
FIRE
ALARM
SYSTEM
RELAY
ELECTRIC
LOCK
18 AWG 2 COND.
ALUMINUM / GLAZING ENTRY
ALUMINUM FRAME MEDIUM STILE-
DARK BRONZE ANODIZED W/
GLASS PANEL
1" INSULATED
TEMP. CLEAR
GLAZING
10
"
8'-8"± R.O.
(VERIFY)
3'-0"
DOOR2"
2'-10"
2"2"
2'-10"
2"
9'
-
0
"
±
R
.
O
.
(
V
E
R
I
F
Y
)
2'
-
6
1
/
4
"
1
3
/
4
"
4'
-
2
"
1'
-
8
1
/
2
"
1
3
/
4
"
1 ALUM. GLAZING SYSTEM
2" x 4 1/2" DARK BRONZE ANODIZED
ALUMINUM FRAME W/ 1" INSULATED
TINTED GLAZING TO MATCH EXISTING
(TEMPERED WHERE REQ'D. BY CODE)
3'-3 1/2"
(VERIFY)
2'-8 1/2"
EXISTING
STOREFRONT
TO REMAIN
EXISTING
STOREFRONT
TO REMAIN
1 3/4"1 3/4"±
EXISTING
MULLION
1 3/4"±
EXISTING
MULLION
9'
-
0
"
R
.
O
.
(V
E
R
I
F
Y
)
1
3
/
4
"
1
3
/
4
"
6'
-
0
1
/
2
"
VE
R
I
F
Y
2'
-
6
1
/
4
"
5'
-
1
1
1
/
4
"
R
.
O
.
2'
-
8
3
/
4
"
VF
Y
.
2"
5'
-
7
1
/
4
"
W-2 ALUM. GLAZING SYSTEM
2"
2"
6'-0"± M.O.
2"EQ.EQ.2"
W-3 2" x 4 1/2" DARK BRONZE
ANODIZED ALUM. FRAME
W/ 1" INSUL. TINTED GLZ.
TO MATCH EXIST. (TEMP.
WHERE REQ'D. BY CODE)
ALUM. GLAZING SYSTEM
2" x 4 1/2" DARK BRONZE
ANODIZED ALUM. FRAME
W/ 1" INSUL. TINTED GLZ.
TO MATCH EXIST. (TEMP.
WHERE REQ'D. BY CODE)
4'-0"± M.O.
2"2"
6'
-
3
3
/
4
"
R
.
O
.
2'
-
8
3
/
4
"
VF
Y
.
2"
5'
-
1
1
3
/
4
"
2"
7'
-
0
"
DO
O
R
HARDWARE GROUPS
1.ALL DOOR HARDWARE SHALL COMPLY WITH FEDERAL AND STATE ACCESSIBILITY REQUIREMENTS
INCLUDING THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN.
2.ALL EXIT DOORS TO BE OPENABLE FROM INSIDE WITHOUT USE OF A KEY, SPECIAL KNOWLEDGE OR
EFFORT.
3.THE MAXIMUM FORCE REQUIRED TO OPERATE ANY DOOR SHALL COMPLY AS FOLLOWS:
A. INTERIOR DOORS = 5 LBS.
B. EXTERIOR DOORS = 8.5 LBS.
C. FIRE-RATED DOORS = MINIMUM ALLOWABLE BY APPROPRIATE ADMINISTRATIVE AUTHORITY.
4.WHEN EXISTING, G.C. TO REVIEW EXISTING HARDWARE CONDITIONS & MAKE RECOMMENDATIONS ON
REPLACEMENTS AS REQ'D. PRIOR TO CONSTRUCTION.
5.REFURBISH ALL EXISTING DOORS LISTED AS "TO REMAIN" TO "LIKE NEW" CONDITION.
6.PROVIDE (1) SET SMOKE GASKETING @ ALL RATED DOOR ASSEMBLIES.
7.GENERAL CONTRACTOR SHALL COORDINATE ALL HARDWARE GROUPS AND FINISHES W/ OWNER PRIOR
TO ORDERING.
8.COORDINATE THE KEYING OF LOCKS WITH OWNER.
9.HARDWARE SHALL INCLUDE ALL NECESSARY ACCESSORIES SUCH AS SCREWS, BOLTS, NUTS, ANCHORS,
TOGGLE BOLTS, AND OTHER FASTENERS AS REQUIRED FOR A COMPLETE INSTALLATION.
10.INSTALL HARDWARE PER MANUFACTURER'S RECOMMENDATIONS.
11.ALL DOORS WHICH OPEN TOWARDS AN ADJACENT WALL SHALL BE SUPPLIED WITH WALL, DOOR, OR
OVERHEAD STOPS.
12.CONTRACTOR SHALL VERIFY ALL DOOR HARDWARE PER SPECIFIC CODE REQUIREMENTS FOR THIS
FACILITY.
13.CONTRACTOR SHALL COORDINATE THE INSTALLING OF ALL CYLINDER LOCKS W/ OWNER.
14.PROVIDE HARDWARE SUBMITTAL TO ARCHITECT & TENANT FOR APPROVAL PRIOR TO CONSTRUCTION.
15.ALL HARDWARE ON ALUMINUM DOORS & FRAMES SHALL BE FINISHED TO MATCH DOOR & FRAME
FINISH, TYP. U.N.O.
16. INTERIOR DOOR HARDWARE SHALL BE US26D FINISH, TYPICALLY, U.N.O.
'1' VESTIBULE - SUPPLIED/INSTALLED BY G.C. (U.N.O.)
(3) -HINGES (4 12"x4 12")
(1) -CLOSER - LCN 4000 SERIES - MATCH DOOR COLOR
(1) -ALUMINUM THRESHOLD - SEE 2/A2.4
(1) -OFFSET PULL - MATCH DOOR COLOR
(1) - PUSH BAR - MATCH DOOR COLOR
(1) -CYLINDER - MUST ACCEPT SMALL FORMAT
INTERCHANGEABLE CORES
(1) -SMALL FORMAT INTERCHANGEABLE CORE SUPPLIED
BY SALON LOFTS
(1) -WEATHERSTRIPPING
(1) -"DOOR TO REMAIN UNLOCKED DURING STORE
OPERATION" SIGNAGE
(1) -ACCESS CONTROL HARDWARE PACKAGE BY
SALON LOFTS VENDOR. SEE ACCESS CONTROL
HARDWARE SPEC. BELOW FOR ADDITIONAL
INFORMATION.
'2' VESTIBULE - SUPPLIED/INSTALLED BY G.C. (U.N.O.)
(4) -HINGES (4 12"x4 12")
(1) -PULL - SUPPLIED BY S.L./INSTALLED BY G.C.
(T.O. HANDLE @ 5'-6" A.F.F.)
(1) - PUSH PLATE - IVES 8200 (US32D)
(1) - CLOSER - LCN 4000 SERIES
(1) -FLOOR STOP - IVES FS448 US26D
(2) - KICK PLATE - IVES 8400 PA28 8"x34"
'3' TOILET
(4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D
(1) -PRIVACY LOCKSET - SCHLAGE S40 (JUP) 626
(1) -CLOSER - HAGER 5200 (AL)
(1) -A.D.A. ACCESSIBLE 'UNISEX' RESTROOM SIGNAGE.
(MATTE BLACK W/ WHITE LETTERS - 6"W. X 9"H.)
(2) -COAT HOOKS (MOUNTED VERTICALLY -
1 @ 4'-0" A.F.F. & 1 @ 5'-6" A.F.F., CENTER BOTH
HORIZ. ON INSIDE FACE OF DOOR)
(1) -WALL STOP - HAGER 236W (32D)
'4' UTILITY
(4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D
(1) -PASSAGE LATCHSET - SCHLAGE S10D (JUP) 626
(1) -CLOSER - HAGER 5200 (AL)
(1) - WALL STOP - HAGER 236W (32D)
'5' LOFT ENTRY
(1) -HEAVY DUTY TRACK W/ BRACKETS
(8) -SET TRACK MOUNT 5/8" SPACERS
(4) -5" MIN. L. STAINLESS STL. LAG SCREWS
(2) -HEAVY DUTY DOOR HANGERS
(2) -BEARING ASSEMBLIES
(1) -PULL (T.O. HANDLE @ 5'-6" A.F.F.)
(2) -BOTTOM GUIDE #1705 (SEE 9sim./A6.0)
(1) -DEADBOLT LOCK (KEYED HALLWAY SIDE)
SCHLAGE B561BD (626)
(1) - HARDWOOD SILL GUIDE TRACK W/ INTEGRAL STRIKE
'6' LOFT ENTRY
(4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D
(1) -ENTRY LOCKSET - SCHLAGE S51 (JUP) 626
(1) -WALL STOP - HAGER 236W (32D)
(*) -SMOKE/SOUND GASKETING AT SPA LOFT ONLY
(*) - DOOR BOTTOM SWEEP AT SPA LOFT ONLY
PEMKO ALUMINUM WITH BLACK NEOPRENE INSERT
OR EQUAL
'7' SIDE DOOR - SUPPLIED/INSTALLED BY G.C. (U.N.O.)
(3) -(E) HINGES
(1) -(E) CLOSER
(1) -(N) ALUMINUM THRESHOLD - SEE 2/A2.4
(1) - (E) PULL
(1) -(E) PUSH BAR
(1) -(N) CYLINDER - MUST ACCEPT SMALL FORMAT
INTERCHANGEABLE CORES
(1) -(N) SMALL FORMAT INTERCHANGEABLE CORE
SUPPLIED BY SALON LOFTS
(1) - (E) SET OF WEATHERSTRIPPING
(1) -(N) "DOOR TO REMAIN UNLOCKED DURING STORE
OPERATION" SIGNAGE
(1) -(N) ACCESS CONTROL HARDWARE PACKAGE BY
SALON LOFTS VENDOR. SEE ACCESS CONTROL
HARDWARE SPEC. BELOW FOR ADDITIONAL
INFORMATION.
'8' SPA VESTIBULE ENTRY
(4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D
(1) -PASSAGE LATCHSET - SCHLAGE S10D (JUP) 626
(1) -CLOSER - HAGER 5200 (AL)
(1) -WALL STOP - HAGER 236W (32D)
(1) -SMOKE/SOUND GASKETING
(1) - DOOR BOTTOM SWEEP PEMKO ALUMINUM WITH
BLACK NEOPRENE INSERT OR EQUAL
'9' VACANT LEASE SPACE - SUPPLIED/INSTALLED BY G.C.
(4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D
(1) - CLOSER - HAGER 5200 (AL)
(1) -ENTRY LOCKSET - SCHLAGE S51 (JUP) 626
(1) -WALL STOP - HAGER 236W (32D)
'10' COMMON DOOR - SUPPLIED/INSTALLED BY G.C. (U.N.O.)
(3) -(E) HINGES
(1) -(E) CLOSER
(1) -(E) ALUMINUM THRESHOLD
(1) - (E) SMOKE GASKETING
(1) -(N) STOREROOM LOCKSET SCHLAGE ND96PD (JUP)626
(1) -(N) SMALL FORMAT INTERCHANGEABLE CORE
SUPPLIED BY SALON LOFTS
[NOTE: FINAL HARDWARE PACKAGE TO BE DETERMINED BY
MANUF./SUPPLIER BASED ON DESIGN DETAILS THESE
DWGS.]
DOOR OPENING & HARDWARE NOTES
DOOR
MATERIAL
MARK LOCATION SIZE (NOMINAL)
width x height x thickness
DOOR
TYPE
FRAME
MATERIAL
RATING DETAIL NUMBER
HEAD JAMB SILL
REMARKS / NOTESHDWARE
GROUP
FRAME
TYPE
NOTES:
1.SEE SPECIFICATIONS AND SHEETS A6.0 & A6.1 FOR DOOR DETAILS.
DOOR SCHEDULE
ACCESS CONTROL HARDWARE SPECIFICATIONS
DOOR TYPESGENERAL DOOR & FRAME NOTES
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
FRAME TYPES
101A VESTIBULE '101'3'-0" x 7'-0"ALUM./GLAZING ALUM.-A 1 -------1
101B VESTIBULE '101'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING ALUM.-B 2 -------2
111 UTILITY '111'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 4 -------3
01 LOFT '01'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 6 -------3
108 TOILET '108'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 3 -------3
1.TENANT'S GENERAL CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND ALTER SPECIFICATIONS AS
REQUIRED TO MATCH EXISTING BUILDING SHELL WHEN INDICATED. CONTACT TENANT & ARCHITECT
IMMEDIATELY TO NOTIFY.
2.SEE SPECIFICATIONS FOR STOREFRONT GLAZING SYSTEM & GLASS SPECIFICATIONS.
3.COORDINATE HOLLOW METAL FRAME WIDTH REQUIRED WITH ACTUAL WALL TYPE THICKNESS OF SCHEDULED
WALL TYPE.
4.VERIFY ALL ROUGH OPENING SIZES WITH DOOR/FRAME MANUFACTURER.
5.INSTALL ALL FRAMES AND DOORS PER MANUFACTURERS DETAILS & RECOMMENDATIONS.
6.SLIDING DOORS TO PROVIDE 2'-10" (34") MIN. CLEAR WIDTH IN THE FULL OPEN POSITION.
7.PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO SYSTEM FABRICATION, INCLUDING CONTACT INFORMATION
FOR QUESTIONS.
8.ALL FRAMES ARE SHOWN FROM EXTERIOR, TYP.
9.ALUMINUM GLAZING SYSTEM COLOR TO MATCH EXISTING STOREFRONT GLAZING SYSTEMS (VERIFY IN FIELD).
10.HORIZONTAL GLAZING MULLIONS TO BE PROVIDED AND INSTALLED SUCH THAT THE ELEVATION OF THE
MULLIONS MATCHES EXISTING STOREFRONT SYSTEMS. G.C. TO VERIFY IN FIELD.
11.CONTRACTOR SHALL VERIFY CONDITION OF ALL EXISTING DOORS AND HARDWARE TO REMAIN. REPLACE OR
REFURBISH ALL REQUIRED TO ENSURE DOOR & HARDWARE IS FULLY FUNCTIONAL & WEATHERTIGHT. REMOVE
ANY EXISTING SIGNAGE / DECALS.
04 LOFT '04'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
05 LOFT '05'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK-
107 SPA VESTIBULE '107'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 8 --12 A6.1 ---3
109 TOILET '109'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 3 -------3
OPENING SCHEDULES
A0.1
25 LOFT '25'3'-0" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 8 A6.0 9sim.A6.0 6'-0" LONG DOOR TRACK-
A.GENERAL: PROVIDE THE LINEAR EMERGE50 SECURITY PLATFORM SYSTEM AT ACCESS CONTROL DOORS WITH
COMPLETE HARDWARE AND ACCESSORIES AS REQUIRED BY MANUFACTURER.
B.ACCESS CONTROL PERFORMANCE IN THE EVENT OF AN EMERGENCY:
1.IN THE EVENT OF A FIRE ALARM OR SPRINKLER SYSTEM ACTIVATION, A DRY CONTACT FIRE RATED RELAY
INSTALLED BY THE FIRE ALARM VENDOR WILL CHANGE STATE FROM "NORMALLY CLOSED" TO "NORMALLY
OPEN" AND DISRUPT THE POSITIVE LEG OF THE LOCKING DEVICE POWER. THE RELAY WILL CHANGE STATE
BACK TO "NORMALLY CLOSED" ONCE THE FIRE ALARM ACTIVATION HAS BEEN RESET, AT WHICH TIME THE
LOCKING DEVICE WILL REENGAGE.
2.IN THE EVENT OF A LOSS OF BUILDING POWER, THE LOCKING DEVICE WILL DISENGAGE. THERE IS NO BACKUP
BATTERY CONNECTED TO THE POWER SUPPLY. ONCE THE POWER IS RESTORED, THE SYSTEM WILL REBOOT
AND REENGAGE THE LOCKING DEVICE.
C.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPLICABLE REQUIREMENTS
FOR ACCESS AND FOR FIRE RATINGS.
1.HEIGHTS TO COMPLY WITH APPLICABLE CODES AND BHMA RECOMMENDATIONS.
2.ADJUST HARDWARE FOR SMOOTH OPERATION.
3.SEE ELECTRICAL & SHEET A3.0 FOR POWER AND DATA CONNECTIONS REQUIRED AT ACCESS CONTROLLED
DOORS.
4.SEE DIAGRAM BELOW FOR TYPICAL FIRE ALARM RELAY CONFIGURATION.
D.EQUIPMENT: ACCESS CONTROL HARDWARE TO BE PROVIDED BY ACCESS CONTROL VENDOR. EQUIPMENT
INCLUDED, BUT IS NOT LIMITED TO:
1.STOREFRONT MOUNTED EXTERIOR PROXIMITY CARD READER
2.MAGNETIC LOCK
3.EXIT RELEASE BUTTON WITH MOTION DETECTING SENSOR
4.ACCESS CONTROL CONTROLLER PANEL WITH FIRE ALARM SYSTEM RELAY
E.CONTACT SALON LOFTS FOR VENDOR.
02 NAIL LOFT '02'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 5 A6.0 9sim.A6.0 8'-6" LONG DOOR TRACK-
03 LOFT '03'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 5 A6.0 9sim.A6.0 8'-6" LONG DOOR TRACK-
06 LOFT '06'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK-
07 SPA LOFT '07'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 6 --12 A6.1 ---3
08 SPA LOFT '08'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 6 --12 A6.1 ---3
09 LOFT '09'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
10 LOFT '10'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK-
11 LOFT '11'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 5 A6.0 9sim.A6.0 8'-6" LONG DOOR TRACK-
12 LOFT '12'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
13 LOFT '13'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
15 LOFT '15'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 6 -------3
16 LOFT '16'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
17 LOFT '17'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK-
18 LOFT '18'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
19 LOFT '19'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
20 LOFT '20'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
21 LOFT '21'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
22 LOFT '22'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
23 LOFT '23'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
24 LOFT '24'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 6 -------3
110A VACANT LEASESPACE 3'-0" x 7'-0" (EXIST.)H.M. (EXIST.)H.M. (EXIST.)20 MIN.-10 --------
110B VACANT LEASESPACE 3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 9 -------3
113 HALLWAY '113'3'-0" x 7'-0" (EXIST.)ALUM./GLZ. (EXIST.)ALUM. (EXIST.)--7 ------REPLACE GLAZING IN DOOR- SEE 1/A1.0 & 1/A1.1.-
14 LOFT '14'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK-
(EXIST.)
ROOM FINISH SCHEDULE
ROOM
NO.LOCATION REMARKS / NOTESMAT'L FINISH NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST MAT'L HEIGHT
CEILINGWALLSBASEFLOOR
NOTES:
1.WHERE APPLICABLE, ALL TILE JOINTS ON THE FLOOR MUST ALIGN WITH TILE JOINTS OF THE TILE BASE. SEE DETAIL 8/A2.2.
2.PROVIDE A SEAMING PLAN FOR APPROVAL TO ARCHITECT & SALON LOFTS' REPRESENTATIVE FOR F5 VINYL SHEET FLOORING INSTALLATIONS WHEN APPLICABLE.
FINISH SPECIFICATIONS
01 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P6/P2 P1/P2EXP. DECKV.I.F.SEE 1/A4.0 FOR WEST WALL / SEE 2/A4.0 FOR SOUTH WALL.P2
101VESTIBULE CONC F7/F4 T1 -T1 -T1 T1 T1 P1/P2 GYP. BD.9'-0" A.F.F.SEE 5/A6.4 FOR HEIGHTS & FINISHES.P3
103WAITING CONC FI/F2/F3 B1 B1 --P3 P1 --GYP. BD.9'-0" A.F.F.SEE 5/A6.4 FOR HEIGHTS & FINISHESP3
104HALLWAY CONC F1/F2 B1 -B1 -P7/P1 -P7/P1 -EXP. DECKV.I.F.-P2
02 NAIL LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1/P2 P1 GYP. BD.9'-0" A.F.F.SEE 2/A4.0 FOR SOUTH WALL / SEE 5/A6.4 FOR HEIGHTS & FINISHES.P3
102HALLWAY CONC F1/F2 ---B1/T1 ---P7/P1/T1EXP. DECKV.I.F.P2
106HALLWAY CONC F1/F2 B1 B1 B1 B1 P7/P1P7/P1/P2P7/P1/P2P7/P1/P2EXP. DECKV.I.F.SEE 2/A4.0 FOR SOUTH WALL FINISH DIRECTIVE.P2
11 LOFT CONC F1 B1 B1 B1 B1 P6 P1/P2 P1/P2 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR EAST WALL / SEE 2/A4.0 FOR SOUTH WALL.P2
FINISH
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
108TOILET CONC.F1 B4 T1 T1 B4 P4 T1/P5 T1/P4 P4 GYP. BD.9'-0" A.F.F.-P3
4" STANDARD#114 LUNAR DUST#C40NR3P114 PINNACLEROPPEB1RUBBER WALL BASE (1/8" THICK)120' COIL & PRE-FORMED CORNERS AS REQ'D.
-#SW7641 COLLONADE GRAYSEE SPECIFICATIONSSHERWIN WILLIAMSP1WALL PAINT -
18x18#24301 MAGNOLIA WHITESAVANNAHFLORIDA TILET1CERAMIC TILE GROUT: MAPEI #00 WHITE (1/8" MAX. GROUT JOINTS)
NOTES:
1.ALL PARTIAL HEIGHT WALLS TO RECEIVE METAL 'J' BEAD OR 'TEAR STRIP' AT TOP. SEE DETAIL 4/A6.3.
2.SEE FINISH PLAN GENERAL NOTES FOR PAINT SHEEN REQUIREMENTS.
3.G.C. TO PROVIDE MATERIAL SAMPLES FOR ALL FINISHES SPECIFIED TO OWNER FOR APPROVAL PRIOR TO ORDERING AND/OR CONSTRUCTION.
4.RUBBER WALL BASE SHALL WRAP AROUND CORNERS MIN. 2'-0" (OR TO INSIDE CORNER) BEFORE A JOINT IS ALLOWED.
5.FLOOR TILE AT TOILET ROOM TO HAVE ROLLED-ON WATERPROOFING APPLIED ON EXISTING FLOORING & UP WALL SURFACES 4" PRIOR TO INSTALLATION. WATERPROOFING TO EXTEND MIN. 2'-0" HORIZONTALLY BELOW ADJACENT FLOOR
FINISHES, TYP. WATERPROOFING TO BE MAPEI MAPELASTIC AQUADEFENSE OR APPROVED EQUAL. SEE FINISH DETAILS FOR MORE INFORMATION.
SIZECOLOR/PRODUCT NUMBERPATTERN/STYLEMANUFACTURERKEYPRODUCT/MATERIAL REMARKS:
-#909-58 BLACKMATTE FINISHFORMICAPL-3PLASTIC LAMINATE -
24x24#7025 MEGA#DT138 TATTOOED MODULARKARASTANF2CARPET TILE (FIELD)QUARTER TURN INSTALLATION
-#6212 WHEAT STRANDMATTE FINISHFORMICAPL-2PLASTIC LAMINATE STRAND PATTERN TO RUN VERTICALLY ALONG SURFACES
6" COVED#114 LUNAR DUST#C60CR3P114 PINNACLEROPPEB2RUBBER WALL BASE (1/8" THICK)120' COIL & PRE-FORMED CORNERS AS REQ'D.
BROADLOOM (12' W.)#989 DRIVE IN#DC084 GROOVINKARASTANF3CARPET (ACCENT)NO SEAMS ACCEPTABLE- ONE PIECE
-#SW7006 EXTRA WHITESEE SPECIFICATIONSSHERWIN WILLIAMSP3WALL / CEILING PAINT -
-T.B.D.SEE SPECIFICATIONSSHERWIN WILLIAMSP6WALL PAINT VERIFY W/ TENANT
-#SW7023 REQUISITE GRAYSEE SPECIFICATIONSSHERWIN WILLIAMSP4WALL PAINT -
-#SW7082 STUNNING SHADESEE SPECIFICATIONSSHERWIN WILLIAMSP5WALL PAINT -
-#SW7018 DOVETAILSEE SPECIFICATIONSSHERWIN WILLIAMSP7WALL PAINT (WAINSCOT)-
ACOUSTICAL CEILING TILES ARMSTRONG #1912 9/16" BEVELED TEGULAR WHITE 24x24x9/16"
ACOUSTICAL CEILING GRID ARMSTRONG SUPRAFINE XL WHITE (WH)9/16"ALL VISIBLE CEILING SUSPENSION WIRES TO BE PAINTED WHITE
-ACT1
-#SW7646 FIRST STARSEE SPECIFICATIONSSHERWIN WILLIAMSP2WALL / CEILING PAINT -
24x24#23805 CARBONURBANITEFLORIDA TILEF7CERAMIC TILE GROUT: MAPEI #47 CHARCOAL (1/8" MAX. GROUT JOINTS)
-#W-448 FP AFROMOSIA NIGERIAFRENCH POLISH FINISHARBORITEPL-4PLASTIC LAMINATE GRAIN PATTERN TO RUN VERTICALLY
-#34337 LITHOS ANTHRACITEREJUVENATIONS STONE RUNARMSTRONGF5VINYL SHEET FLOORING INCLUDE COLOR MATCHED VINYL WELD MATERIAL / INSTALLATION
24x24 (1/4 TURN)#438 WINDSWEPT#L8513 FIRST STEPLEESF4ENTRY MAT
-#5875-58 NEUTRAL WEFTMATTE FINISHFORMICAPL-1PLASTIC LAMINATE -
BROADLOOM (12' W.)#7025 MEGA#DC138 TATTOOEDKARASTANF6CARPET (SPA SUITE)-
24x24 CUT TO 6"H#23811 CONCRETEURBANITEFLORIDA TILEB4CERAMIC TILE GROUT: MAPEI #27 SILVER (1/8" MAX. GROUT JOINTS)
24x24#23811 CONCRETEURBANITEFLORIDA TILEF1CERAMIC TILE GROUT: MAPEI #27 SILVER (1/8" MAX. GROUT JOINTS)
24x24 CUT TO 4"H#23805 CARBONURBANITEFLORIDA TILEB3CERAMIC TILE GROUT: MAPEI #47 CHARCOAL (1/8" MAX. GROUT JOINTS)
FINISH SCHEDULES
A0.2
03 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1/P2 P1 EXP. DECKV.I.F.SEE 2/A4.0 FOR SOUTH WALL FOR FINISH DIRECTIVE.P2
04 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1 P1 EXP. DECKV.I.F.-P2
05 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1/P2 P6 EXP. DECKV.I.F.SEE 2/A4.0 FOR SOUTH WALL FINISH DIRECTIVE.P2
06 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1 P1 EXP. DECKV.I.F.-P2
07 SPA LOFT CONC F6 B1 B1 B1 B1 P1 P1 P1 P1 A.C.T.9'-0" A.F.F.-ACT-1
08 SPA LOFT CONC F6 B1 B1 B1 B1 P1 P1 P1 P1 A.C.T.9'-0" A.F.F.-ACT-1
09 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1 P1 EXP. DECKV.I.F.-P2
10 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2
12 LOFT CONC F1 B1 B1 B1 B1 P1 P1/P2 P6 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR EAST WALL FINISH DIRECTIVE.P2
13 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2
14 LOFT CONC F1 B1 B1 B1 B1 P6/P2 P1/P2 P1 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR EAST WALL / SEE 2/A4.0 FOR NORTH WALL.P2
15 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1/P2 P6 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH & EAST WALLS DIRECTIVE.P2
16 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P1 P6 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2
17 LOFT CONC F1 B1 B1 B1 B1 P1 P6/P1 P1 P1 EXP. DECKV.I.F.-P2
18 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P6 P1 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2
19 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2
20 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P1 P6 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2
21 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2
22 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P6 P1 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2
23 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P1 P6 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2
24 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P6/P1 P1/P2EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH & WEST WALLS DIRECTIVE.P2
25 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1/P2P6/P1/P2EXP. DECKV.I.F.SEE 1/A4.0 FOR SOUTH & WEST WALLS DIRECTIVE.P2
105HALLWAY CONC F1/F2 -B1 -B1 -P7/P1 -P7/P1EXP. DECKV.I.F.-P2
107SPA VESTIBULE CONC F6 B1 B1 B1 B1 P1 P1 P1 P1 A.C.T.9'-0" A.F.F.-ACT-1
109TOILET CONC.F1 B4 B4 T1 T1 P4 P4 T1/P4 T1/P5 GYP. BD.9'-0" A.F.F.-P3
110VACANT LEASE SPACE CONC EXIST.-EXIST.EXIST.EXIST.-EXIST.EXIST.EXIST.EXP. DECKV.I.F.-EXIST.
111UTILITY CONC F5 B2 B2 B2 B2 P1 P1 P1 P1 EXP. DECKV.I.F.-P2
112HALLWAY CONC F1/F2 -B1 -B1 -P7/P1/P2 -P7/P1/P2EXP. DECKV.I.F.-P2
113HALLWAY CONC F1/F2 B1 B1 -B1 P7/P1/P2P7/P1 -P7/P1EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2
114HALLWAY CONC F1/F2/F3 B1 -B1 -P7/P1 -P7/P1 P1 VARIES V.I.F.-VARIES
RESPONSIBILITY SCHEDULE
RUBBER WALL BASE (1/8" THICK) - 4" STANDARD
B2 RUBBER WALL BASE (1/8" THICK) - 6" COVED
F2 CARPET TILE (FIELD)840 S.F. + 25% = 1,050 S.F.
F3
T1 CERAMIC TILE - WALL 304 S.F. + 25% = 380 S.F.
94 S.F. + 25% = 118 S.F.
1,230 L.F. + 10% = 1,353 L.F.
33 L.F. + 10% = 36 L.F.
KEY PRODUCT/MATERIAL QUANTITY
B1
F6 CARPET (SPA SUITE)249 S.F. + 25% = 312 S.F.
SINGLE LOFTS 9 (9 POS)
DOUBLE LOFT 0 (0 POS)
PREMIUM LOFT 13 (13 POS)
NAIL LOFT 2 (2 POS)
SPA LOFT 1 (1 POS)
TOTAL POS 25
NOTE:
- OWNER TO VERIFY QUANTITIES PRIOR TO ORDERING MATERIALS
CARPET (ACCENT)
CASEWORK SCHEDULE
NOTE: GENERAL CONTRACTOR SHALL TAKE DELIVERY, PROVIDE SECURE STORAGE OF OWNER SUPPLIED ITEMS AND INSTALL AS INDICATED ON THE PLANS OR AS DIRECTED BY OWNERS REPRESENTATIVES.
SL = SALON LOFTS GC = GENERAL CONTRACTOR LL = LANDLORD E = EXISTING
REMARKSFURNISHINSTALL
SL
REMARKSFURNISHINSTALL
LOFTS
FINISHES-ALL AREAS
HALLWAY/COMMON
UTILITY ROOM
TOILET ROOMS
GCLLESLGCLL SLGCLLESLGCLL
SLGCLLESLGCLL
SLGCLLESLGCLL
SLGCLLESLGCLL
SLGCLLESLGCLL
GENERAL MECH./ELEC./PLUMB.SLGCLLESLGCLL
REMARKSFURNISHINSTALL
SLGCLLESLGCLL
REMARKSFURNISHINSTALL
SIGNAGE W/ WHITE LETTERS - 6"W X 9"H
PERMITS & FEES
INSPECTIONS
TEMPORARY HEAT
TEMPORARY ELECTRICAL
TEMPORARY WATER
JOB PHONE / FAX
CLEAN UP
INSURANCE
FIELD VERIFICATION
WARRANTIES & BONDS
CERTIFICATE OF OCCUPANCY
ROOF (EXISTING)
CONCRETE SLAB
CONCRETE SLAB/FLR. REPAIR
DEMISING WALL STUDS/FRAMING
DEMISING WALL GYP. BD.
DEMISING WALL INSULATION
EXTERIOR SIGNS
EXTERIOR ENTRY DOORS & FRAMES
EXTERIOR REAR DOOR & FRAME
EXTERIOR WINDOWS
EXT. STOREFRONT MODIFICATIONS
STOREFRONT GLASS DECALS
EXT. FINISH MODIFICATIONS
STRUCTURAL STEEL
DEMOLITION - INTERIOR
DEMOLITION - BUILDING SHELL
DOOR HARDWARE
INT. WD. DOORS & H.M. FRAMES
FIRE EXTINGUISHERS/CABINETS -
INCLUDES GLAZING
UNLESS NOTED OTHERWISE
SEE DRAWINGS FOR WORK REQ'D.
-
SEE DRAWINGS FOR WORK REQ'D.
G.C. TO COORDINATE WITH SIGN VENDOR
LEVEL & SMOOTH /SEE DWGS. FOR WORK REQ'D.
EXIST. SLAB / SEE DWGS. FOR WORK REQ'D.
WATERTIGHT
-
-
-
-
-
-
-
-
-
-
-WATER SERVICE MAIN
SANITARY SERVICE MAIN
PLUMBING VENT STUB THRU ROOF
HVAC UNITS (COMPLETE SYSTEM)
HVAC ROOFTOP CURBS
HVAC STRUCTURAL SUPPORTS
HVAC - VVT/VAV UNITS
HVAC DISTRIBUTION (COMPLETE)
HVAC DAMPERS
TEMPERATURE CONTROL SYSTEM
DUCTWORK SMOKE DETECTORS
TOILET EXHAUST FAN / GRILLE
NAIL LOFT EXHAUST FAN / GRILLES
SPA EXHAUST FAN/GRILLE
AIR BALANCE REPORT
ELECTRICAL SERVICE/METERS
ELECTRICAL DISCONNECT IN SPACE
ELECTRICAL PANELS
ELEC. BREAKER FOR HVAC UNITS
ELEC. WIRING FOR HVAC UNITS
ELEC. SERVICE RECEPT. FOR HVAC
FIRE ALARM SYSTEMS
EXT. SIGN ELECTRICAL
EXT. LIGHT AT EXIT DOORS
WATER METER
PLUMB. SAN, HW, CW PIPING
GAS PIPING/ACCESSORIES FOR HVAC
GAS PIPING/ACCESSORIES FOR W.H.
GAS METER
CONDENSATE PIPING
FIRE SPRINKLER SERVICE
FIRE SPRINKLER DISTRIBUTION
LOW VOLTAGE WIRING
SECURITY SYSTEM WIRING
ALARM WIRE RELAY FOR DOORS G.C. TO COORDINATE WITH TENANT'S VENDOR
G.C. TO PROVIDE CONDUITS AS REQUIRED-
-
-
-
SEE DRAWINGS FOR WORK REQ'D.
--
-
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
IF REQUIRED
SEE DRAWINGS FOR WORK REQUIRED
N/A
2 NEW UNITS / 2 EXISTING UNITS
SEE DRAWINGS FOR WORK REQ'D.MILLWORK / CABINETS
SHAMPOO SINK / FAUCET
SALON CHAIRS
ELECTRICAL WIRING / DEVICES
LIGHT FIXTURES & BULBS
PEDI-SPA CHAIR
NAIL SINK / FAUCET
SPA LOFT SINK / FAUCET
MISC. FURNITURE
FRAMED WALL MIRRORS
HAIR DRYERS ON WHEELS
COAT HOOKS
HAIR TRAP BY G.C.
-
-
SEE ELECTRICAL FOR WORK REQUIRED
-
-
-
-
-
MISC. FURNITURE
GRAPHICS
LIGHT FIXTURES
COMPUTER STATION MILLWORK
MAIL STATION MILLWORK
ELECTRICAL WIRING / DEVICES
DATA / TELEPHONE WIRING
LOFT IDENTIFICATION/SIGNAGE
FRAMED WALL MIRRORS
COMPUTER SYSTEM
CREDIT CARD MACHINE
INTERIOR SIGNAGE
GRAPHIC DISPLAY PANELS
VESTIBULE MIRROR
WATER COOLER
-
-
-
-
N/A
-
-
-
G.C. TO PROVIDE WOOD BLOCKING IN WALL
-
-
GC TO COORD. WITH TENANT'S MILLWORK
VENDOR, PROVIDE ELEC. SUPPLY/CONNECTIONGC TO COORD. WITH TENANT'S MILLWORKVENDOR, PROVIDE ELEC. SUPPLY/CONNECTION
-
SHELVES
WATER HEATERS
EXPANSION TANK
RE-CIRC. PUMP
WATER SOFTENER SYSTEM
UTILITY SINK
WASHER/DRYER
PHONE PANEL PLYWD.
LIGHT FIXTURES
ELECTRICAL WIRING / DEVICES
TELEPHONE / DATA WIRING
DRINKING FOUNTAIN
WATER CLOSET
LAVATORY SINK / FAUCET
GRAB BARS
TOILET ACCESSORIES
WALL MIRROR
ACCESSIBILITY SIGNAGE
LIGHT FIXTURES
ELECTRICAL WIRING / DEVICES
VANITY COUNTERTOP
TRASH CANS
SOAP / LOTION DISPENSER
MILLWORK STORAGE CABINETS
PAINTING
CARPET/CARPET TILES
VINYL FLOORING
RUBBER BASE
CERAMIC TILE
CERAMIC TILE ACCESSORIES/GROUT
ACOUSTICAL CLG. TILE/GRID
RUBBER TRANSITION STRIPS
ENTRY MAT -
WHERE APPLICABLE
INCLUDE ALL COMPONENTS OF ACT1
INCLUDE ALL SCHLUTER STRIPS AS DETAILED
-
-
-
SEE A2.4
-
-
-
-
MATTE BLACK UNISEX RESTROOM SIGNAGE
-
-
-
-
-
N/A
-
-
-
-
-
-
-
FURNITURE SCHEDULE MISCELLANEOUS OWNER SUPPLIED ITEMS FINISH MAT'L. QUANTITIES
LOFT QUANTITIES
KEYQUANTITY
22
DESCRIPTION
SHAMPOO SINK BASE W/ SHAMPOO SINKC1
44 STYLIST BASE CABINETC2
48 STYLIST UPPER CABINETC3
44 STYLIST COUNTERTOP (VERIFY LENGTH W/ PLAN SET DETAILS)C4
26 FRAMED WALL MIRROR 'A' (3'-4" X 4'-8")C5
0C6
2 PAY STATIONC7
0 MAIL STATIONC8
2 SPA CABINETS (BASE & UPPER CABINETS, COUNTERTOPS)
1 NAIL POLISH CABINET
C9
1 NAIL LOFT STORAGE
C10
1 NAIL CARTSC12
FRAMED WALL MIRROR 'B' (3'-4" X 6'-0")
C11
C13
2 WAY FINDING MILLWORK. SEE A4.2C14
C15 FRAMED WALL MIRROR 'C' (2'-6" X 4'-2") - TOILET ROOM2
C16 STYLIST TOOL CART22
NOTE:
- OWNER TO VERIFY QUANTITIES PRIOR TO ORDERING MATERIALS
QUANTITY DESCRIPTION
NOTE:
- OWNER TO VERIFY QUANTITIES PRIOR TO ORDERING MATERIALS
QUANTITY DESCRIPTIONKEYKEY
22 STYLIST CHAIRSF1
0 EUROPEAN SINK / CHAIRF2
NAIL SINKF3
1 NAIL TABLESF4
2 NAIL CHAIRSF5
1 PEDI-SPAF6
1 WASHER / DRYERF7
2 COMPUTERF8
6 (VERIFY)WAITING CHAIRSF9
2 (VERIFY)WAITING TABLESF10
2F19
25 LOFT SIGNAGE W/ CARD HOLDERF12
0 INDIVIDUAL CARD HOLDERF13
22 HAIR DRYER ON WHEELSF14
2 TOILET ROOM TRASH CANF15
2 SOAP / LOTION DISPENSERF16
0 5' X 5' FATIGUE MATF17
0 3' X 4' FATIGUE MATF18
1
0 (VERIFY)WAITING BENCHF11
F20 1 UTILITY TRASH CAN
SPA TABLE
M1 LOFT & ENTRY DOOR PULL21
COAT HOOKS50
'A' LIGHT FIXTURE (CUSTOM LAMP SHADE FIXTURE)22
'B' LIGHT FIXTURE (4'-0" TRACK WITH 3 HEADS)22
MATTE BLACK UNISEX SIGNAGE W/ WHITE LETTERS - 6"W X 9"H2
M2
M3
M5
M6
M7
M8
M9
M4
M10
M11
M12
M13
M14
M15
M16
M17
M18
'C' LIGHT FIXTURE (COMPACT FLUORESCENT DOWNLIGHT)0
2
'D' LIGHT FIXTURE (METAL HALIDE DOWNLIGHT)
10
11
'E' LIGHT FIXTURE (2'X4' LAY-IN FIXTURE)2
'F' LIGHT FIXTURE (3'-6" FLUORESCENT WALL LIGHT)44
'G' LIGHT FIXTURE (1'X4' INDUSTRIAL FLUORESCENT FIXTURE)4
'H' LIGHT FIXTURE (LED LINEAR WALL WASH FIXTURE)
'J' LIGHT FIXTURE (LINEAR LED FLEX FIXTURE)SEE DETAILS
'C2' LIGHT FIXTURE (HALOGEN DOWNLIGHT WITH DIMMER)
'K' LIGHT FIXTURE (2'-6" FLUORESCENT WALL LIGHT)2
'EM2' LIGHT FIXTURE (OUTDOOR EMERGENCY LIGHT)2
'L' LIGHT FIXTURE (5'Ø FLUORESCENT FIXTURE)2
'C1' LIGHT FIXTURE (C.F.L. DOWNLIGHT W/ EMER. BATTERY PACK)
QUANTITYDESCRIPTIONKEY
'X-1' LIGHT FIXTURE (EXIT LIGHT WITH DIRECTIONAL ARROW)13
'X-2' LIGHT FIXTURE (RECESSED EMERGENCY LIGHT)7
SLIDING DOOR TRACK HARDWARE - 8'-6" LONG TRACK -
LOFTS 02, 03, 11
M26
3
SLIDING DOOR TRACK HARDWARE - 10'-0" LONG TRACK -
LOFTS 04, 09, 12, 13, 14, 16, 18, 19, 20, 21, 22, 2312
M27
LOFT TYPE QUANTITY
NOTE:
G.C. SHALL VERIFY SALON LOFTS SUPPLIED FINISH MATERIAL QUANTITIES INDICATED
WITHIN 7 DAYS OF BEING AWARDED CONTRACT FOR CONSTRUCTION. COORD. FINAL
VERIFIED QUANTITIES TO SALON LOFTS REPRESENTATIVE.
INCLUDING FINAL CONNECTION
SLIDING DOOR TRACK HARDWARE - 6'-10" LONG TRACK -
LOFT 05, 06, 10, 174
FRAMED WALL MIRROR 'D' (6'-8" X 5'-0") - WAITING ROOM1
ELECTRICAL TRANSFORMER
M20
'M' LIGHT FIXTURE (4'Ø FLUORESCENT FIXTURE)2
HARDWOOD SILL GUIDE TRACK - 8'-6" LONG TRACK -
LOFTS 02, 03, 11
HARDWOOD SILL GUIDE TRACK - 10'-0" LONG TRACK -
LOFTS 04, 09, 12, 13, 14, 16, 18, 19, 20, 21, 22, 23
HARDWOOD SILL GUIDE TRACK - 7'-1" LONG TRACK -
LOFT 05, 06, 10, 17
SEE DRAWINGS FOR WORK REQUIRED
IF APPLICABLE
VESTIBULE MIRROR TRIM -
LADDER HANGER -
TANKLESS WATER HEATERS (INT. WALL MTD.)
M21
'N' LIGHT FIXTURE (3'Ø FLUORESCENT FIXTURE)1
M28
INTERIOR ALUM. DOORS & FRAMES INCLUDES GLAZING
ROOF WORK (NEW)USE LANDLORD APPROVED ROOFER IF REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
G.C. TO PROVIDE WOOD BLOCKING IN WALL
G.C. TO PROVIDE WOOD BLOCKING IN WALL
G.C. TO PROVIDE WOOD BLOCKING IN WALL
G.C. TO PROVIDE WOOD BLOCKING IN WALL
G.C. TO PROVIDE WOOD BLOCKING IN WALL
SEE DRAWINGS FOR WORK REQ'D.
N/A
INCLUDE AT TRANSITION PIECES AS DETAILED
3
12
4
94 SQ.YD.+25%= 118 SQ.YD.
11 SQ.YD.+25%= 14 SQ.YD.
35 SQ.YD. + 25%= 44 SQ.YD.
-
-
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
-
-
-
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
2 NEW / 2 EXISTING
M19
M29
InterlockingRock BLOCK WALL
-InterlockingRock PANEL WALL
modulararts InterlockingRock BLOCKS - 'OHM'9
C17 SALON LOFTS PUCK AND GRAPHIC PANEL1
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
SEE DRAWINGS FOR WORK REQ'D.
INTERIOR GLZ./SILLS/HEADS/ETC.
G.C. TO PROVIDE WOOD BLOCKING IN WALL
F4 CARPET (ENTRY MAT)33 S.F. + 25% = 42 S.F.
4 SQ.YD. + 25%= 5 SQ.YD.
N/A
SEE DRAWINGS FOR WORK REQ'D.
F21 WAITING GATHERING HEIGHT CHAIR
F22 WAITING GATHERING HEIGHT TABLE M22
'P' LIGHT FIXTURE (2'Ø FLUORESCENT FIXTURE)0
M24 modulararts InterlockingRock PANELS - PATTERN T.B.D.17
M30
SEE DRAWINGS FOR WORK REQ'D.
N/A
SEE DRAWINGS FOR WORK REQ'D.
SKYLIGHTS
-
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
URINAL
TOILET PARTITIONS
N/A
F23 2 46" LED-LCD DISPLAY & MOUNT
WAY FINDING MILLWORK
LED-LCD DISPLAY & MOUNT
G.C. TO COORD. ELEC./DATA REQUIREMENTS.
-
2 (VERIFY)
1 (VERIFY)
SEE DETAILS
M23
0 'R' LIGHT FIXTURE (DOWNLIGHT FIXTURE)
B4 CERAMIC TILE BASE - 6" HIGH 12 S.F. + 25% = 15 S.F.
F1 CERAMIC TILE - FLOOR 3,678 S.F. + 25% = 4,597 S.F.
N/A
B3 CERAMIC TILE BASE - 4" HIGH 0 S.F. + 25% = 0 S.F.
-
N/A
N/A
F7 CERAMIC TILE - FLOOR 14 S.F. + 25% = 15 S.F.
M25
M31
M32
HARDWOOD SILL GUIDE TRACK - 6'-3" LONG TRACK -
LOFT 251 RESPONSIBILITY
SCHEDULE
A0.3
SLIDING DOOR TRACK HARDWARE - 6'-0" LONG TRACK -
LOFT 251
M33
N/A
N/A
-
W
T
W
GRID GRID
GRID
GRID
NOTE: AREA OF FLOOR SLAB TRENCHING
(SHOWN HATCHED) FOR UNDER-SLAB PLUMBING
& ELECTRICAL. REPLACE ALL FLOOR SLAB
REMOVED WITH 'LIKE NEW' CONSTRUCTION, BUT
IN NO CASE LESS THAN 4" CONC. SLAB W/
6x6-W1.4/21.4 WWF AT MID-DEPTH. DOWEL PIN
TO EXIST. SLAB AS REQ'D.
1
4
6
5
7
7
9
9
10
5
5
5
111
3
8
6'
-
0
"
M.
O
.
8'
-
8
"
M.
O
.
1
4'
-
0
"
M.
O
.
4'
-
0
"
M.
O
.
4'
-
0
"
M.
O
.
22 2 2 2
2
22
2
6'
-
8
"
4'
-
8
"
6'
-
8
"
8"
4'
-
8
"
3
12
12
1313
14
14
14
15
16
16
16
16 16
4'
-
0
"
10
'
-
8
"
3'
-
5
"
8'
-
2
"
9'
-
2
3
/
8
"
3'
-
7
1
/
2
"
2'
-
6
"
TR
E
N
C
H
TYP.
TYP.
TR
E
N
C
H
6'
-
7
"
±
TR
E
N
C
H
21'-0"6"5'-1"7'-5"12'-4"4'-6"1'-2"
1'
-
3
"
3'-4"
8 TYP.
2'-3"2'-3"
1'
-
0
"
2'
-
0
"
2'
-
9
"
3 TYP.
4"3'-8"22'-2 1/2"2'-10"8'-8 1/4"15'-3 3/4"15'-8 3/4"5'-11 1/4"1'-5"5'-2"9'-8"4'-0"
4'
-
6
"
4'
-
6
"
TYP.11'-1"±TRENCH TRENCH
4'
-
5
1
/
2
"
±
TR
E
N
C
H
12
4'-0"30'-4"60'-9 1/4"4'-0"
8
3 TYP.
TYP.
17
'
-
2
"
4'
-
0
"
10
'
-
8
"
1'
-
8
"
1'
-
8
"
7"
2'
-
0
1
/
2
"
4'
-
0
3
/
4
"
TR
E
N
C
H
TR
E
N
C
H
4'-0"12'-0"7'-0"31'-5"TRENCH3'-2"TRENCH
8'
-
8
"
8 TYP.
18
18
4'
-
0
"
20
2'
-
0
"
19
TYP.TYP.
3'-9 1/2"
TYP.TYP.TYP.TYP.
17
21
17
17
TYP.
TYP.
14 14 23
TYP.
NOTE: TRENCHING LAYOUT INDICATED IS
BASED ON CONNECTIONS TO EXISTING
UNDERGROUND SANITARY LINE LOCATIONS
ASSUMED BY EXISTING TOILET ROOM LOCATIONS.
CONTRACTOR SHALL VERIFY AND COORDINATE
ANY DEVIATIONS REQUIRED.
1515
22
15
EXISTING COMMON EXIT CORRIDOR
15 TYP.
18
18
N
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
DEMOLITION & FLOOR
TRENCHING PLAN
A1.0
1
A1.0 3/16"=1'-0"
DEMOLITION & FLOOR TRENCHING PLAN
DEMOLITION KEY NOTES
1
2
3
4
5EXISTING STOREFRONT DOOR TO BE REMOVED SHOWN DASHED. PREP
OPENING FOR NEW STOREFRONT SYSTEM INFILLED TO MATCH EXISTING
AS SCHEDULED.
EXIST. STOREFRONT WINDOWS TO REMAIN. G.C. IS RESPONSIBLE FOR ALL
STOREFRONT REPAIR NEEDED. ENSURE ALL SEALS, GASKETS, GLASS,
FRMG., ETC ARE IN GOOD CONDITION. REPLACE ALL DAMAGED PARTS.
REMOVE THROUGH WALL/GLASS PENETRATIONS. PATCH
GLASS/FRAMING SYSTEM TO MATCH EXIST. AS REQUIRED.
DEMOLISH, REMOVE, AND LEGALLY DISCARD ALL EXISTING
IMPROVEMENTS THROUGHOUT AREA OF WORK INCLUDING, BUT NOT
LIMITED TO: PARTITIONS, DOORS, CEILINGS, FLOORING, MILLWORK,
LIGHTS, ELECTRICAL, PLUMBING, AND DUCTWORK, ETC. (SHOWN
DASHED). VERIFY EXTENTS.
EXISTING STRUCTURAL COLUMN & FURRING TO REMAIN SHOWN
SHADED. PROTECT FROM DAMAGE DURING DEMOLITION AS REQUIRED.
SEE SHEET A2.0 FOR ADDITIONAL INFORMATION.
REMOVE EXISTING PORTION OF MASONRY WALL AS INDICATED. PREP
OPENING FOR NEW WINDOW & FRAME AS SCHED. SEE SHEET A1.1 FOR
EXTENTS OF NEW WORK REQUIRED.
REMOVE EXISTING PORTION OF MASONRY WALL AS INDICATED. PREP
OPENING FOR NEW STOREFRONT AS SCHED. SEE SHEET A1.1 FOR
EXTENTS OF NEW WORK REQUIRED.
EXISTING ELECTRICAL SERVICE PANELS TO BE REMOVED / RELOCATED.
REMOVE ALL UNUSED CONDUITS/WIRES/ETC. BACK TO POINT OF
ORIGINATION AS REQ'D. COORD. REQUIREMENTS WITH ELEC. PLANS.
EXISTING CONCRETE FLOOR SLAB TO REMAIN. REMOVE ANY EXISTING
FLOOR COVERINGS / COATINGS / ELECTRICAL OUTLETS. PATCH & REPAIR
AS NEEDED TO 'LIKE NEW' CONDITION. CONCRETE SLAB TO BE SMOOTH
AND LEVEL PRIOR TO NEW CONSTRUCTION; REPAIR ANY AREAS OF HEAVE
ACCORDINGLY. PREPARE SURFACE FOR NEW FINISHES AS SCHEDULED.
EXISTING HVAC UNITS ON ROOF ABOVE SERVING TENANT'S SPACE TO
REMAIN. PROTECT AS REQ'D. REMOVE ALL ASSOCIATED DUCTWORK, ETC.
BACK TO UNIT DROPS. SEE MECHANICAL PLANS FOR NEW WORK REQ'D.
EXISTING HVAC UNIT ON ROOF ABOVE SERVING TENANT'S SPACE TO BE
REMOVED AND REPLACED. COORDINATE WITH MECHANICAL FOR
PLACEMENT OF NEW HVAC UNIT.
REMOVE EXISTING MAIL DROP BOX IN STOREFRONT DOOR. REPLACE
WITH GLAZING TO MATCH EXISTING. SEE A1.1 FOR ADDITIONAL
INFORMATION.
REMOVE EXISTING FURRING AROUND EXISTING COLUMN AS INDICATED.
PROTECT COLUMN FROM DAMAGE DURING DEMOLITION & CONSTR.
EXISTING WATER METERS TO BE REMOVED AS REQ'D. CAP ANY EXISTING
CONNECTIONS AS REQ'D. & SEE MECH. DRAWINGS FOR NEW SERVICE.
FALSE COLUMNS & SOFFITS ABOVE TO BE REMOVED. PATCH AND REPAIR
ADJACENT SURFACES AS REQ'D. TO MATCH EXISTING.
REMOVE EXIST. FLOOR SINKS/FLOOR DRAINS & CAP CONNECTIONS
BELOW SLAB AS REQ'D. SEE MECH. DRAWINGS FOR MORE INFORMATION.
REMOVE EXISTING ROOF DECK & ROOFING AS REQ'D. TO INSTALL NEW
SKYLIGHTS. SEE SHEET A1.1 FOR MORE INFORMATION.
EXISTING DOOR & FRAME TO REMAIN. PROTECT AS REQ'D. DURING
DEMOLITION & CONSTRUCTION. G.C. TO REPLACE / REPAIR ANY
DAMAGE/ HARDWARE AS REQUIRED.
NEW UNDERGROUND PLUMBING TRENCH TO CONNECT TO EXISTING
UNDERGROUND SANITARY LINE. VERIFY ALL EXISTING LOCATIONS.
EXISTING EXTERIOR METAL RAILING TO BE REMOVED. REPAIR CONCRETE
SIDEWALK AS REQUIRED TO MATCH ADJACENT SURFACES.
EXIST. FIREPLACE TO BE REMOVED ALONG WITH ASSOCIATED VENTING,
GAS LINES, ETC. PATCH & REPAIR ADJACENT AS REQ'D. TO MATCH EXIST.
REMOVE EXISTING H.M. DOOR & FRAME AS REQ'D. PREP OPENING FOR
NEW MASONRY INFILL AS INDICATED ON SHEET A1.1.
EXISTING GREASE TRAP RECESSED INTO FLOOR SLAB TO BE REMOVED IN
ITS ENTIRETY, INCLUDING ALL ASSOCIATED PLUMBING UNDER SLAB.
INFILL SLAB WITH 'LIKE CONSTRUCTION' TO MATCH EXISTING.
EXISTING WATER LINE & EXTERIOR HOSE BIB TO REMAIN. PROTECT FROM
DAMAGED DURING DEMOLITION AND NEW CONSTRUCTION.
7
8
9
6
10
11
12
13
14
15
16
17
18
19
20
21
22
23
W W
GRID GRID
GRID
GRID
EXIST. STL. JOISTS, TYP.
VERIFY LOCATIONS
IN FIELD.
A1.1
2
A1.2
1
4'
-
8
"
4'
-
0
"
M.
O
.
6'
-
8
"
4'
-
0
"
M.
O
.
6'
-
8
"
4'
-
0
"
M.
O
.
A1.1
3
A1.1
3
A1.1
3
5'-3 1/2"14'-6"16'-6"26'-6"26'-2"±
A1.1
4
A1.2
2
A1.2
3
2'
-
8
"
6'
-
0
"
4'
-
8
"
8'
-
8
"
8"
1
3
2
22
3
3
3
4
4
55
5
5 5
66
6
7
8
9
8
6'-0"
11
10
13
6
13
12
RETURN GYP. BD.
TO FRAME AT HEAD
AND JAMBS. SEAL
TO FRAME.
LINE OF GYP. BD.
WALL BEYOND.
EXIST. EXTERIOR BIT.
SURFACE TO REMAIN.
HEAD FLASHING,
SEALANT & SHIM
SPACE.
NEW STL. LINTEL W/
CMU INFILL AT DOOR
HEAD- SEE STRUCT.
ALL EXPOSED STL.
SHALL BE PRIMED &
PAINTED.
EXISTING CMU WALL
(SHOWN SHADED) TO
REMAIN. PATCH TO
MATCH AS REQ'D.
DUE TO NEW
CONSTRUCTION.
TOP OF
INTERIOR SLAB
+0'-0"
EXIST. CONC. SLAB
TO REMAIN.
EXIST. CMU. WALL
(SHOWN SHADED).
2"4 12"
6'
-
0
"
2'
-
8
"
NEW 2"x4 1/2" DARK
BRONZE ANODIZED
THERMALLY BROKEN
ALUM. GLAZING
FRAME W/ 1"
TINTED INSUL. GLASS
(CENTER SET).
PREFIN. SILL
FLASHING TO MATCH
GLAZING FRAMES.
FLASHING TO FULLY
SEAT FRAME & LAP
OVER CMU WALL
WITH HEMMED DRIP
EDGE AS INDICATED.
PATCH/REPAIR/
REPLACE INTERIOR
WALL FURRING TO
MATCH EXIST. AS
NEEDED.
P.LAM. WINDOW
SILL OVER ICE &
WATER MEMBRANE
ON 34" TREATED
PLYWD. SILL.
EXIST. EXTERIOR
CONC. SURFACE.
VFY. LEVEL WITH
INTERIOR SLAB.
PREFINISHED ALUM.
THRESHOLD SET IN
BED OF MASTIC.
NEWEXIST.
1/2" EXPANSION
JOINT.
9'
-
0
"
NEW 2"x4 1/2" DARK
BRONZE ANODIZED
THERMALLY BROKEN
ALUM. STOREFRONT
SYSTEM W/ 1"
TINTED INSUL. GLASS
(CENTER SET).
RETURN GYP. BD.
TO FRAME AT HEAD
AND JAMBS. SEAL
TO FRAME.
LINE OF GYP. BD.
WALL BEYOND.
PATCH/REPAIR/REPLACE
INT. WALL FURRING TO
MATCH EXISTING AS
NEEDED. EXTEND
AND/OR PROVIDE NEW
FURRING SYSTEM AT
DOOR / WINDOW HEAD
& UP TO ROOF DECK.
HEAD FLASHING,
SEALANT & SHIM
SPACE.
NEW STL. LINTEL W/
CMU INFILL AT DOOR
HEAD- SEE STRUCT.
ALL EXPOSED STL.
SHALL BE PRIMED &
PAINTED.
EXISTING SOFFIT &
MASONRY WALL
(SHOWN SHADED) TO
REMAIN. PATCH TO
MATCH AS REQ'D.
DUE TO NEW
CONSTRUCTION.
2"4 12"
TOP OF
INTERIOR SLAB
+0'-0"
EXIST. EXTERIOR
CONC. SURFACE TO
REMAIN.
6'
-
4
"
NEW 2"x4 1/2" DARK
BRONZE ANODIZED
THERMALLY BROKEN
ALUM. STOREFRONT
SYSTEM W/ 1"
TINTED INSUL. GLASS
(CENTER SET).
RETURN GYP. BD.
TO FRAME AT HEAD
AND JAMBS. SEAL
TO FRAME.
LINE OF GYP. BD.
WALL BEYOND.
EXISTING SOFFIT &
MASONRY WALL
(SHOWN SHADED) TO
REMAIN. PATCH TO
MATCH AS REQ'D.
DUE TO NEW
CONSTRUCTION.
2"4 12"
TOP OF
INTERIOR SLAB
+0'-0"
B.O. SOFFIT
+9'-6"± (VFY.)
2'
-
8
"
HEAD FLASHING,
SEALANT & SHIM
SPACE.
NEW STL. LINTEL W/
CMU INFILL AT DOOR
HEAD- SEE STRUCT.
ALL EXPOSED STL.
SHALL BE PRIMED &
PAINTED.
B.O. SOFFIT
+9'-6"± (VFY.)
EXIST. CONC. SLAB
TO REMAIN.
PATCH/REPAIR/
REPLACE INTERIOR
WALL FURRING TO
MATCH EXIST. AS
NEEDED.
P.LAM. WINDOW
SILL OVER ICE &
WATER MEMBRANE
ON 34" TREATED
PLYWD. SILL.
PREFIN. SILL
FLASHING TO MATCH
GLAZING FRAMES.
FLASHING TO FULLY
SEAT FRAME & LAP
OVER MASONRY
WALL WITH
HEMMED DRIP EDGE
AS INDICATED.
EXIST. FOUNDATION
WALL (SHOWN
SHADED).
#4x1'-0" LG. DOWEL
@ 24" O.C. CENTER
ON NEW/EXIST.
JOINT.
G.C. FIELD VFY.
-0'-8"
#4 Ø CONT.
EXIST. CMU. FND. WALL
ASSUMED- G.C. FIELD
VFY.- GROUT TOP COURSE
SOLID CONTINUOUS.
#4x1'-0" LG. DOWEL @
MID-DEPTH @ 24" O.C.
EMBED 4" INTO EXIST.
CONC. W/ EPOXY
ADHESIVE.
NEW CONC. SLAB
INFILL AS REQ'D. FOR
NEW DOOR OPENING.
PATCH / REPAIR /
REPLACE INT. WALL
FURRING TO MATCH
EXISTING AS
NEEDED. EXTEND
AND/OR PROVIDE
NEW FURRING
SYSTEM AT DOOR /
WINDOW HEAD &
UP TO ROOF DECK.
PATCH/REPAIR/REPLACE
INT. WALL FURRING TO
MATCH EXISTING AS
NEEDED. EXTEND
AND/OR PROVIDE NEW
FURRING SYSTEM AT
DOOR / WINDOW HEAD
& UP TO ROOF DECK.
STL. ANGLE-
SEE STRUCT.
SKYLIGHT SET IN
CONTIN. BED OF
MASTIC COMPATIBLE
WITH ROOFING
MATERIAL.
STAINLESS STEEL
FASTENERS AS
REQ'D. BY MFR.
SKYLIGHT TO BE
INSTALLED WEATHER-
TIGHT PER MFR.'S
RECOMMENDATIONS.
LAP FLASHING UP & OVER
NEW 2x WD. CURB & TIE
INTO EXIST. ROOF- TYP.
ALL SIDES.
EXIST. ROOF TO REMAIN.
REPAIR AS NECESSARY.
NEW TREATED (2) 2x
WD. CURB AT ALL SIDES.
EXIST. MTL. DECKING.
3"
4'-1 1/4"
VERIFY W/ MANUFACTURER
4"
MI
N
.
3"
W W
GRID GRID
GRID
GRID
EXIST. STL. JOISTS, TYP.
VERIFY LOCATIONS
IN FIELD.
A1.1
2
A1.2
1
4'
-
8
"
4'
-
0
"
M.
O
.
6'
-
8
"
4'
-
0
"
M.
O
.
6'
-
8
"
4'
-
0
"
M.
O
.
A1.1
3
A1.1
3
A1.1
3
5'-3 1/2"14'-6"16'-6"26'-6"26'-2"±
A1.1
4
A1.2
2
A1.2
3
2'
-
8
"
6'
-
0
"
4'
-
8
"
8'
-
8
"
8"
1
3
2
22
3
3
3
4
4
55
5
5 5
66
6
7
8
9
8
6'-0"
11
10
13
6
13
12
BUILDING SHELL
MODIFICATIONS PLAN &
DETAILS
A1.1
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
1
A1.1 1/8"=1'-0"
BUILDING SHELL MODIFICATIONS PLAN
2
A1.1 3/4"=1'-0"
WALL SECTION @ DOOR
KEY NOTES
1
2
3
4
NEW DARK BRONZE ALUMINUM/GLAZING DOOR & FRAME AS
SCHEDULED WITH 1" TINTED INSULATED GLASS (TEMPERED
WHERE REQUIRED BY CODE). SEE DOOR SCHEDULE.
NEW DARK BRONZE ANODIZED ALUMINUM GLAZING FRAME INFILL
AS REQUIRED WITH 1/8" TINTED TEMPERED SAFETY GLASS TO
MATCH EXISTING STOREFRONT.
NEW DARK BRONZE ANODIZED ALUMINUM GLAZING FRAME WITH
1" TINTED INSULATED GLASS (TEMPERED WHERE REQUIRED BY
CODE) AS SCHEDULED.
PATCH, REPAIR & INFILL EXISTING CONCRETE FLOOR SLAB AS
REQUIRED. SLAB TO BE LEVEL & SMOOTH THROUGHOUT FOR NEW
FINISHES AS SCHEDULED.
PROVIDE & INSTALL 4'-0"x4'-0" DOME STYLED THERMAL MOUNTED
CURB FIXED SKYLIGHT BY WASCO SKYLIGHT "DCSNT" MODEL #5252
WITH A CLEAR ANODIZED ALUMINUM FINISH AT ROOF.
ALUMINUM PERIMETER PRE-SEALED AT FACTORY, INSTALLATION
ON TREATED WOOD CURB. ALL ROOFING, CURBS, ETC. FOR
COMPLETE WATERTIGHT INSTALLATION. SEE DETAIL 5/A1.1 &
STRUCTURAL PLANS FOR MORE INFORMATION.
EXTEND GYP. BD. & FURRING UP TO DECK WHERE NONE EXISTS.
ALIGN W/ EXIST. WALL FURRING & PREP FOR FINISHES AS SCHED.
REPLACE EXISTING RTU WITH NEW RTU IN SAME LOCATION AS
SCHEDULED. SEE MECH. DRAWINGS FOR MORE INFORMATION.
EXISTING RTU TO REMAIN. SEE MECHANICAL PLANS.
EXISTING GAS METERS. PROTECT FROM DAMAGE DURING
DEMOLITION AND CONSTRUCTION.
REPLACE EXISTING GLAZING IN STOREFRONT DOOR W/ 1/8"
TEMPERED TINTED SAFETY GLASS TO MATCH EXISTING (VERIFY).
NEW RTU AS SHOWN. VERIFY FINAL LOCATION AND ADDITIONAL
INFORMATION WITH STRUCTURAL & MECHANICAL DRAWINGS.
INFILL OPENING WITH CMU / FURRING / GYP. BD. CONSTRUCTION
TO MATCH EXISTING.
EXISTING DOOR & FRAME. SEE DOOR SCHEDULE FOR ANY WORK
REQUIRED.
5
6
7
8
9
3
A1.1 3/4"=1'-0"
WALL SECTION @ WINDOW
5
A1.1 1 1/2"=1'-0"
SKYLIGHT DETAIL
4
A1.1 3/4"=1'-0"
WALL SECTION @ WINDOW
N
10
11
12
13
GRID GRID
GRID GRID
GRID GRID
U.N.O., EXIST. CONDITIONS
AT EXTERIOR STOREFRONT
WALLS TO REMAIN.
U.N.O., EXIST. CONDITIONS
AT EXTERIOR STOREFRONT
WALLS TO REMAIN.
U.N.O., EXIST. CONDITIONS
AT EXTERIOR STOREFRONT
WALLS TO REMAIN.
LEASELINE LEASELINE
PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, &
INSTALLATION BY TENANT'S SIGN VENDOR. ELEC.
CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON
ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN
DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL.
CENTER SIGNAGE AS INDICATED.
PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, &
INSTALLATION BY TENANT'S SIGN VENDOR. ELEC.
CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON
ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN
DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL.
CENTER SIGNAGE AS INDICATED.
EXISTING GAS
SERVICE METERS.
A1.1
2
A1.1
4
REMOVE EXISTING PORTION OF WALL
& INFILL WITH NEW DARK BRONZE
ANODIZED FRAME W/ GLAZING AS
SCHED. PAINT ADJACENT WALL
SURFACES AS REQ'D. TO MATCH
EXISTING. COORD. WITH LANDLORD.
W-3
4'-8"4'-0"
M.O.
6'-8"4'-0"
M.O.
6'-8"4'-0"
M.O.
W-3W-3
A1.1
3
A1.1
3
A1.1
3
W-2101AW-1
REMOVE EXISTING PORTION OF WALL &
INFILL WITH NEW DARK BRONZE
ANODIZED FRAME W/ GLAZING AS SCHED.
REMOVE EXISTING PORTION OF WALL
& INFILL WITH NEW DARK BRONZE
ANODIZED STOREFRONT SYSTEM AS
SCHED.
REMOVE EXISTING STOREFRONT DOOR
& TRANSOM AND INFILL WITH NEW
DARK BRONZE ANODIZED
STOREFRONT FRAME W/ GLAZING AS
SCHED. TO MATCH EXISTING.
W-1
REMOVE EXISTING STOREFRONT DOOR
& TRANSOM AND INFILL WITH NEW
DARK BRONZE ANODIZED
STOREFRONT FRAME W/ GLAZING AS
SCHED. TO MATCH EXISTING.
W-1
REMOVE EXISTING STOREFRONT DOOR
& TRANSOM AND INFILL WITH NEW
DARK BRONZE ANODIZED
STOREFRONT FRAME W/ GLAZING AS
SCHED. TO MATCH EXISTING.
SALON LOFTS
SALON LOFTS
HAIR SKIN NAILS MASSAGE
INFILL EXISTING DOOR OPENING W/
CMU TO MATCH EXISTING. PAINT TO
MATCH REAR WALL. COORDINATE
COLOR WITH LANDLORD.
GRID GRID
GRID GRID
GRID GRID
U.N.O., EXIST. CONDITIONS
AT EXTERIOR STOREFRONT
WALLS TO REMAIN.
U.N.O., EXIST. CONDITIONS
AT EXTERIOR STOREFRONT
WALLS TO REMAIN.
U.N.O., EXIST. CONDITIONS
AT EXTERIOR STOREFRONT
WALLS TO REMAIN.
LEASELINE LEASELINE
PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, &
INSTALLATION BY TENANT'S SIGN VENDOR. ELEC.
CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON
ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN
DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL.
CENTER SIGNAGE AS INDICATED.
PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, &
INSTALLATION BY TENANT'S SIGN VENDOR. ELEC.
CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON
ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN
DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL.
CENTER SIGNAGE AS INDICATED.
EXISTING GAS
SERVICE METERS.
A1.1
2
A1.1
4
REMOVE EXISTING PORTION OF WALL
& INFILL WITH NEW DARK BRONZE
ANODIZED FRAME W/ GLAZING AS
SCHED. PAINT ADJACENT WALL
SURFACES AS REQ'D. TO MATCH
EXISTING. COORD. WITH LANDLORD.
W-3
4'-8"4'-0"
M.O.
6'-8"4'-0"
M.O.
6'-8"4'-0"
M.O.
W-3W-3
A1.1
3
A1.1
3
A1.1
3
W-2101AW-1
REMOVE EXISTING PORTION OF WALL &
INFILL WITH NEW DARK BRONZE
ANODIZED FRAME W/ GLAZING AS SCHED.
REMOVE EXISTING PORTION OF WALL
& INFILL WITH NEW DARK BRONZE
ANODIZED STOREFRONT SYSTEM AS
SCHED.
REMOVE EXISTING STOREFRONT DOOR
& TRANSOM AND INFILL WITH NEW
DARK BRONZE ANODIZED
STOREFRONT FRAME W/ GLAZING AS
SCHED. TO MATCH EXISTING.
W-1
REMOVE EXISTING STOREFRONT DOOR
& TRANSOM AND INFILL WITH NEW
DARK BRONZE ANODIZED
STOREFRONT FRAME W/ GLAZING AS
SCHED. TO MATCH EXISTING.
W-1
REMOVE EXISTING STOREFRONT DOOR
& TRANSOM AND INFILL WITH NEW
DARK BRONZE ANODIZED
STOREFRONT FRAME W/ GLAZING AS
SCHED. TO MATCH EXISTING.
SALON LOFTS
SALON LOFTS
HAIR SKIN NAILS MASSAGE
INFILL EXISTING DOOR OPENING W/
CMU TO MATCH EXISTING. PAINT TO
MATCH REAR WALL. COORDINATE
COLOR WITH LANDLORD.
EXTERIOR ELEVATIONS
A1.2
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
1
A1.2 1/8"=1'-0"
NORTH ELEVATION
2
A1.2 1/8"=1'-0"
WEST ELEVATION 3
A1.2 1/8"=1'-0"
EAST ELEVATION
HALLWAY
AL
I
G
N
SEALANT TO
MATCH GROUT.
WALL TILE
T1
WALL SYSTEM AS
SCHEDULED.
VESTIBULE
SEALANT TO
MATCH GROUT.
WALL TILE
T1
LAP TILE.
1'-6" FROM FACE OF
FRAME/TILE TO CORNER
GYP. BD.
3/8"
VFY.
FACTORY EDGE.
3/8"
VFY.
FINISHED
FLOOR (TILE)
5/
8
"
4"
BASE VARIES-
VERIFY
PARTITION WALL
& PAINT PER
SCHED.
HOLD GYP. BD.
5/8" OFF SLAB,
TYP.
TILE MUST BE INSTALLED TIGHT TO
GYP. BD. WALL SURFACE, TYP.
GRID
63
'
-
6
3
/
4
"
LE
A
S
E
L
I
N
E
T
O
L
E
A
S
E
L
I
N
E
101'-0 1/2"
LEASELINE TO LEASELINE
3'-8 1/4"
GRID
GRID
GRID
01020305
04
06
07
107
08
0910
108109
111
11
12
14
15
13
16
17 19
18 20
21
22 23 24
25
101
102103
104
105
106
110
112
113
114
FE
FE
FE
EXISTING CONDITIONS HEIGHTS
BOTTOM OF LOWEST STRUCTURE:11'-0" A.F.F.
BOTTOM OF ROOF DECK:14'-0" A.F.F. @ WEST
12'-8" A.F.F. @ EAST
BOTTOM OF TYP. STRUCT. JOIST 12'-2" A.F.F. @ WEST
11'-0" A.F.F. @ EAST
BOTTOM OF LOWEST OBSTRUCTION 10'-5" A.F.F. (EXIST. RTU DROP)
4'
-
0
"
TY
P
I
C
A
L
P1
101A
1 TYP.
101B
010203
04
05
06
10
7
0708
09
10
9
10
8
10
11
0
B
110
A
111
11
12
14
13
15
113
16
17
18 20
19 21
22 23
24
25
W-
2
W-
1
W-1W-1
W-
3
W-
3
W-
3
6'-0"
PROPOSED FUTURE
WALL KNOCK-OUT
SEE DETAIL 8/A6.1
10 1/2"14'-0 3/4"±4'-7"13'-6"13'-6"13'-6"13'-6"13'-5 1/4"13'-0 1/4"1'-0 3/4"
ALIGN
AL
I
G
N
ALIGN
10
'
-
5
"
12
'
-
5
1
/
2
"
6'
-
0
"
CL
E
A
R
/
H
O
L
D
13
'
-
3
5
/
8
"
3'
-
7
"
4'-0 3/4"
11'-10"9'-5 1/2"10'-5"4'-3 3/4"
10
'
-
7
3
/
4
"
10'-2"6'-3"10'-10 1/2"7'-8 1/2"7'-7"5'-1"10'-11"
2'
-
5
1
/
4
"
±
9'
-
0
"
10
'
-
3
"
10
'
-
3
"
11
'
-
1
1
"
9'
-
3
3
/
4
"
±
10
1
/
2
"
10'-11"4'-2"14'-2"13'-7"10'-5"10'-5"11'-3"7'-1 1/2"4'-6"8'-5"
6'-1 1/4"
2'
-
6
"
2'
-
1
0
"
2'
-
1
0
"
3'
-
7
"
4'
-
1
0
"
4'
-
2
1
/
2
"
9'
-
5
"
4'
-
2
"
12
'
-
1
0
3
/
4
"
11
'
-
1
0
1
/
2
"
4'
-
2
"
3'
-
0
"
5'-10"
2'-10"5'-6"5'-5"
3'-6"
5'
-
0
"
2'
-
4
"
7'-2 3/4"
CLEAR/HOLD
18"
HOLD
18
"
MI
N
.
4'-2"5'-10"
3'
-
6
"
5'
-
1
0
"
3'-6"
4"3'-0"
5'
-
1
0
"
3'-6"
3"1'-1"1'-1"
4"
TYP.
7"
TY
P
.
4"
TYP.
3'-0"7"
TYP.
3'-0"4'-0"
3'-5"4'-0"
6'-2"
6'
-
0
"
PR
O
P
O
S
E
D
F
U
T
U
R
E
WA
L
L
K
N
O
C
K
-
O
U
T
SE
E
D
E
T
A
I
L
8
/
A
6
.
1
6'
-
0
"
PR
O
P
O
S
E
D
F
U
T
U
R
E
WA
L
L
K
N
O
C
K
-
O
U
T
SE
E
D
E
T
A
I
L
8
/
A
6
.
1
6'
-
0
"
PR
O
P
O
S
E
D
F
U
T
U
R
E
WA
L
L
K
N
O
C
K
-
O
U
T
SE
E
D
E
T
A
I
L
8
/
A
6
.
1
6'
-
0
"
PR
O
P
O
S
E
D
F
U
T
U
R
E
WA
L
L
K
N
O
C
K
-
O
U
T
SE
E
D
E
T
A
I
L
8
/
A
6
.
1
6'-0"
PROPOSED FUTURE
WALL KNOCK-OUT
SEE DETAIL 8/A6.1
4'
-
0
"
TY
P
I
C
A
L
4'
-
0
"
TY
P
I
C
A
L
18"
MIN.
P7
5'
-
0
"
4'
-
8
"
1'
-
1
0
"
P1P1
P1
P2P1
P5
P7
P5
P6
P5
P5P4
P3P1
P3
P1
P3
P3
P2
P1
P1
P2 P1
P1
P1
P2 P1 P2
P1
P1 P1 P1
P1
P2
P2
P1 P7
P1
P2P1P2
P1
P1
P1P2
P1P2P1
P1
7'-4"3"
P3 4" STUD
58
88
8 8
4
1 TYP.
1 TYP.
1 TYP.
1 TYP.1 TYP.1 TYP.
1 TYP.
23
4
6
7
9
4'
-
2
"
P2
P5
EXI
S
T
.
EXI
S
T
.
EXI
S
T
.
3'
-
8
"
MI
N
.
EXISTING COMMON EXIT CORRIDOR
EXISTING
BUILDING
UTILITY
ROOM
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
N
DIMENSION
FLOOR PLAN
A2.0
1
A2.0 3/16"=1'-0"
DIMENSION FLOOR PLAN
2
A2.0 6"=1'-0"
TYPICAL WALL BASE DETAIL 3
A2.0 3"=1'-0"
ALUMINUM HEAD DETAIL
EXIST. WALLS TO REMAIN. G.C. TO PATCH &
REPAIR EXIST. AS REQ'D. TO 'LIKE NEW' FINISH.
NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD.
ON EA. SIDE OF 3 5/8"(U.N.O.) MTL. STUD FRMG.
@ 24" O.C. FROM FINISH FLOOR TO 9'-6" A.F.F.
NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD.
ON EA. SIDE OF 3 5/8"(U.N.O.) MTL. STUD FRMG.
@ 16" O.C. FROM FINISH FLOOR TO 9'-6" A.F.F.
NON RATED PARTITION: (1) LAYER 5/8" GYP. BD.
ON EA. SIDE OF 3 5/8"(U.N.O.) MTL. STUD FRMG.
@ 24" O.C. W/ 3 1/2" FIBERGLASS SOUND BATT
INSUL. FROM FINISH FLOOR TO B.O. ROOF DECK.
NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD.
ON EA. SIDE OF 6" MTL. STUD FRMG. @ 16" O.C.
W/ 3 1/2" FIBERGLASS SOUND BATT INSUL. FROM
FINISH FLOOR TO B.O. ROOF DECK.
NON-RATED PARTITION:(2) LAYERS 5/8" GYP. BD.
(TYPE VARIES) ON EA. SIDE OF 6" MTL. STUD FRMG.
@ 24" O.C. W/ 5 1/2" FIBERGLASS SOUND BATT
INSUL. FROM FINISH FLOOR TO B.O. ROOF DECK.
SEE 12/A6.1 FOR CONSTRUCTION.
NON-RATED PARTITION:(2) LAYERS 5/8" GYP. BD.
(TYPE VARIES) ON EA. SIDE OF 6" MTL. STUD FRMG.
@ 16" O.C. W/ 5 1/2" FIBERGLASS SOUND BATT
INSUL. FROM FINISH FLOOR TO B.O. ROOF DECK.
SEE 12/A6.1 FOR CONSTR.
NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD.
ON 3 5/8"(U.N.O.) MTL. STUD FRMG. @ 16" O.C.
FROM FINISH FLOOR TO 9'-6" A.F.F.
P3
P1
PARTITION LEGEND
P2
P4
PARTITION NOTES
1.NOTHING IS PERMITTED TO BE ATTACHED,
SUSPENDED, OR PENETRATE THE ROOF DECK ABOVE.
FRAME, BRACE, &/OR SUSPEND AS NEEDED FROM
THE TOP CHORD OF JOISTS OR STRUCT. STEEL WHICH
EXISTS ABOVE SPACE.
2.ALL LIGHT GAUGE METAL WALL STUDS SHALL BE 20
GA. MIN., U.N.O. SEE 1/A6.3 FOR STUD GAUGE
LIMITING HEIGHTS & TYP. FRMG. NOTES.
3.USE W.R. GYP. BD. ADJACENT TO PLUMBING
FIXTURES.
4.G.C. TO ENSURE WALL TO FLOOR TRANSITION IS
STRAIGHT, TRUE, & READY TO RECEIVE BASE AS
SCHEDULED.
5.ALL WALLS WITH MOUNTED CABINETS TO BE FRAMED
WITH METAL STUDS AT 16" O.C. ALL OTHER WALLS
TO BE FRAMED WITH METAL STUDS AT 24" O.C.
VERIFY LOCATIONS AND WALL TYPES WITH PLANS.
6.SEE DETAILS 2/A6.3, 3/A6.3 & 4/A6.3 FOR TYPICAL
FRAMING & FINISHES AT THE TOP OF WALLS.
7.HOLD GYP. BD. OFF FLOOR SLAB 1/4" MAX.
THROUGHOUT SPACE. SEE DETAIL 2/A2.0.
P6
DIMENSION KEY NOTES
EXTEND EXIST. MTL. STUD FURRING & GYP. BD. TO DECK ABOVE ALONG ENTIRE
LEASESPACE PERIMETER WHERE NONE IS PROVIDED.
EXISTING FURRING & GYP. BD. @ STRUCTURAL COLUMN TO REMAIN. EXTEND TO
9'-6" A.F.F. MIN. (IF NOT ALREADY). SEE DETAIL 4/A6.3.
FURR OUT AROUND EXIST. STRUCT. COLUMN W/ MTL. STUD FRAMING & GYP. BD. AS
REQ'D. FURRING TO EXTEND FROM FINISHED FLOOR TO 9'-6" A.F.F. SEE DETAIL 4/A6.3.
FURR OUT AROUND EXIST. STRUCT. COLUMN WITH MTL. STUD FRAMING & GYP. BD. AS
REQ'D. FURRING TO EXTEND FROM FINISHED FLOOR TO BOTTOM OF ROOF DECK.
SEE DETAILS 3/A2.0 & 2/A6.1 FOR LOCATING ALUM. GLAZING SYSTEM & WALL ABOVE.
EXHAUST GRILLE TO BE CENTERED ON NAIL CABINET. COORD. METAL STUD FRAMING
LAYOUT WITH DETAIL 5/A4.2 TO ENSURE EXHAUST GRILLE LOCATION IS MAINTAINED.
COORD. PEDI-SPA & EXHAUST GRILLE LOCATIONS WITH DETAIL 2/A2.3. METAL STUD
FRAMING LAYOUT TO ENSURE EXHAUST GRILLE LOCATION IS MAINTAINED AT PEDI-SPA.
WORK POINT: DIM. TO OUTSIDE CORNER OF GYP. BD. HEADER ABOVE GLASS CORNER.
HOLD WALL FRAMING OFF EXISTING DEMISING WALL 1".
1
2
3
4
P5
P7
5
6
7
8
9
GRID
63
'
-
6
3
/
4
"
LE
A
S
E
L
I
N
E
T
O
L
E
A
S
E
L
I
N
E
101'-0 1/2"
LEASELINE TO LEASELINE
3'-8 1/4"
GRID
GRID
GRID
01020305
04
06
07
107
08
0910
108109
111
11
12
14
15
13
16
17 19
18 20
21
22 23 24
25
101
102103
104
105
106
110
112
113
114
FE
FE
FE
A2.2
1
A6.0
4
A6.3
9
A6.1
2
A6.1
11
A6.1
6
A6.1
8
A4.0
2
TYP.
101A
101B
01
0203
04
05
06
10
7
0708
09
10
9
10
8
10
11
0
B
110
A
111
11
12
14
13
15
113
16
17
18 20
19 21
22 23
24
25
W-
2
W-
1
W-1W-1
W-
3
W-
3
W-
3
TYP.A6.2
2
TYP.24TYP.22
A4.0
10
A4.0
7
A4.0
3
A4.0
4
A4.2
5
A4.2
6
A4.0
6
A4.0
9
A4.0
8
A4.0
11
A4.1
2
A4.1
1
A4.1
3
A4.1
4
A4.2
4
A4.2
2
A4.2
1
A4.2
3
A6.2
1
A6.2
1
A4.0
1
TYP.
A4.0
1
TYP.A4.0
1
TYP.A4.0
1
TYP.A4.0
1
TYP.
A4.0
1
TYP.
A6.0
4
A6.1
9
A6.1
9
A6.0
1
A6.1
9
A6.0
4
A6.0
1
A6.0
1
A6.0
1
A6.0
1
A6.0
1
A6.0
1
A6.0
1
A6.0
7A6.0
1
A6.0
1
A6.0
1
A6.1
9A6.0
1
A6.1
8
A6.1
8
A6.1
8
A6.1
8
A6.1
8
A1.2
3
A1.2
1
A1.2
2
A6.1
11
A6.1
11
A6.1
11
A6.1
11
A6.4
3
A6.4
3
A6.4
3
SIM.
A6.1
6
SIM.A6.1
6
SIM.
TYP.A6.2
2
TYP.22TYP.24
A6.1
6
SIM.A6.1
6
SIM.A6.1
6
SIM.
1
2
7
1
2
1 2125
1
2
1
2
31
1
3
31
4
4
5
5 7 5 5 5 57
7
8
5
7
6
888888
8
7
7
7
9 TYP.
9 TYP.9 TYP.9 TYP.9 TYP.9 TYP.9 TYP.
9 TYP.
9 TYP.
9 TYP.
9 TYP.
10
10
10
111720
14
19
18
15 13
12
16
21
21
23 23
24
24
272525
25
25
26
26
26
2626
26
26
26
26 26
26
26
26
26 26
2626
26
2626
26
26 26 26
28
29
3010
31
32
25
A6.2
7
A6.3
7
29 6
A6.1
6
1
3
A6.1
12
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
FLOOR PLAN
A2.1
1
A2.1 3/16"=1'-0"
FLOOR PLAN - 4,906 S.F.
N
FLOOR PLAN KEY NOTES
LEASELINE
EXTERIOR OF BUILDING.
INTERIOR WALL PARTITION / DEMISING WALL. PROTECT FROM DAMAGE DURING
DEMOLITION AND CONSTRUCTION. REPAIR AS REQUIRED TO 'LIKE NEW' CONDITION.
EXISTING CONCRETE SIDEWALK TO REMAIN. PROTECT FROM DAMAGE DURING
DEMOLITION & CONSTRUCTION. PATCH, REPAIR, OR REPLACE ANY AREAS DAMAGE DURING
CONSTRUCTION TO 'LIKE NEW' CONDITION.
EXISTING ALUMINUM/GLASS STOREFRONT GLAZING SYSTEM TO REMAIN. PROTECT FROM
DAMAGE DURING DEMOLITION & CONSTRUCTION.
EXISTING EXTERIOR STOREFRONT BUILD-OUT WITH SOFFIT ABOVE. PROTECT FROM
DAMAGE DURING DEMOLITION & CONSTRUCTION.
NEW ALUMINUM / GLASS STOREFRONT GLAZING SYSTEM AS SCHEDULED.
G.C. IS RESPONSIBLE FOR ALL STOREFRONT REPAIR NEEDED. SEAL, GASKET, REMOVE
MAILBOXES, ETC. TO EXISTING TO REMAIN.
LINE OF SILL BELOW WINDOWS.
DASHED LINE INDICATES FLOATING GYP. BD. CEILING ABOVE, SEE REFLECTED CEILING PLAN.
PROVIDE 2'x4' FIRE-RATED PLYWOOD BACKING FOR TELEPHONE BOARD & EQUIPMENT @
UTILITY ROOM. COORD. FINAL LOCATION OF TENANT'S PHONE D-MARC ON SITE WITH
OWNER.
WASHER/DRYER UNIT WITH 4" DRYER VENT PIPE IN WALL BEHIND. SEE MECHANICAL PLANS.
SERVICE SINK, SEE PLUMBING FOR DETAILS. PROVIDE WATER RESISTANT GYP. BD. AT AREA
SURROUNDING SINK.
12" DEEP WOOD SHELVING ON METAL SUPPORT BRACKETS MOUNTED ON UTILITY ROOM
WALL AT 6'-0" A.F.F. COORDINATE FINAL LOCATION W/ OWNER PRIOR TO CONSTRUCTION.
TANKLESS HOT WATER HEATERS MOUNTED (BOTTOM AT MIN. 9'-0" ABOVE FINISHED
FLOOR) TO INTERIOR PARTITION WALL. PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING FOR
ATTACHMENT ON WALLS AS REQ'D. SEE ELEC. & PLUMBING PLANS FOR DETAILS.
HOT WATER STORAGE TANK HUNG FROM STRUCTURE ABOVE. SEE PLUMBING PLANS.
ELECTRICAL SERVICE PANELS, SEE ELECTRICAL FOR DETAILS.
UTILITY TRASH CAN TO BE SUPPLIED AND INSTALLED BY SALON LOFTS.
LADDER HANGER TO BE SUPPLIED AND INSTALLED G.C. COORDINATE FINAL LOCATION &
MOUNTING HEIGHTS WITH SALON LOFTS.
PROVIDE SURFACE MOUNT FIRE EXTINGUISHER AT LOCATIONS INDICATED. CLASS B,C SIZE
10. VERIFY FINAL LOCATIONS AND QUANTITIES WITH LOCAL FIRE MARSHALL.
PROVIDE SEMI-RECESSED FIRE EXTINGUISHER CABINET & FIRE EXTINGUISHER AT LOCATIONS
INDICATED. CLASS B,C SIZE 10 EXTINGUISHER. VERIFY FINAL LOCATIONS AND QUANTITIES
WITH LOCAL FIRE MARSHALL.
STYLIST STATION CASEWORK FIXTURES TO BE INSTALLED W/ ONE SIDE TIGHT TO ADJACENT
WALL PARTITION AS SHOWN TYP., UNLESS NOTED OTHERWISE, COORDINATE WITH PLAN.
PROVIDE FINISHED P.LAM. EDGES/SURFACES ON CASEWORK WHERE EXPOSED TO VIEW.
CASEWORK CABINETS, SEE A6.2 FOR DETAILS, MOUNTED WITH BOTTOM OF CABINET @
4'-0" A.F.F. PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING AS REQUIRED FOR ATTACHMENT
OF CASEWORK ITEMS.
PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING IN WALL AS REQUIRED FOR ATTACHMENT OF
CASEWORK / MILLWORK ITEMS.
WOOD FRAMED MIRROR, PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING AS REQUIRED. SEE
INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS & ORIENTATION.
(2) COAT HOOKS MOUNTED @ 5'-0" A.F.F. (SPACED @ 8" O.C.). PROVIDE 3/4" FIRE-RATED
PLYWOOD BACKING IN WALL AS REQUIRED. VERIFY FINAL LOCATION WITH SALON LOFTS'
REPRESENTATIVE ON SITE PRIOR TO INSTALLATION OF BACKING.
NAIL LOFT SINK, SEE 6/A2.2 FOR DETAILS.
FREESTANDING PEDI-SPA. SEE DETAIL 2/A2.3.
DOOR CHIME. DOOR BUTTON @ ENTRY DOOR W/ CHIME LOCATED ABOVE CEILING IN
WAITING #103.
InterlockingRock PANELS OVER GYP. BD. WALL SURFACE. INSTALL PER MANUFACTURER'S
INSTRUCTIONS. SEE ELEVATIONS FOR ADDITIONAL INFORMATION. COORD. W/ SALON
LOFTS' REPRESENTATIVE ON SITE.
InterlockingRock BLOCK WALL (3 BLOCKS WIDE / 3 BLOCKS HIGH). INSTALL PER
MANUFACTURER'S INSTRUCTIONS. SEE ELEVATIONS FOR ADDITIONAL INFORMATION.
COORDINATE REQUIRED STIFFENERS WITH SALON LOFTS' REPRESENTATIVE ON SITE.
ILLUMINATED SALON LOFTS PUCK & GRAPHICS PANEL. PROVIDE 3/4" FIRE-RATED PLYWOOD
BACKING IN WALL AS REQ'D. SEE INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS.
1
2
3
4
5
6
7
8
17
18
19
20
21
22
23
24
25
26
27
28
29
30
9
10
11
12
14
15
16
13
31
32
ACCESSIBLE
SOAP DISPENSER
S.D.
ACCESSIBLE MIRROR
@ VANITY COUNTER
MI.MOUNT MIRROR
@ 40" A.F.F.
MAX.- COORD.
MOUNTING
HEIGHT
WITH VANITY
COUNTER DTL.
HINGE APPROACH LATCH APPROACH FRONT APPROACH
EXCEPTION - 12" IS NOT
REQUIRED UNLESS DOOR HAS
BOTH A CLOSER AND A LATCH
NOTE - ALL DOORS IN ALCOVES
SHALL COMPLY WITH THE
CLEARANCE FOR FRONT
APPROACHES
TO
O
F
S
I
G
N
TY
P
F
O
R
A
L
L
AC
C
E
S
S
S
I
G
N
S
ACCESSIBLE
LAVATORY/MIRROR
COORDINATE
MOUNTING
HEIGHT
WITH
MIRROR
LOCATION
MI.
LAV.
ACCESSIBLE HI-LO
DRINKING FOUNTAIN
ACCESSIBLE P.T.D. /
WASTE RECEPTACLE
P.T.D.
TOWEL
SLOT
ACCESSIBLE SIGNAGE
3'
-
4
"
M
A
X
.
TO
R
E
F
L
E
C
T
I
O
N
SU
R
F
A
C
E
2'
-
3
"
M
I
N
.
2'
-
5
"
M
I
N
.
2'
-
1
0
"
M
A
X
.
T
O
T
H
E
R
I
M
COORDINATE
MOUNTING
HEIGHT
WITH
MIRROR
LOCATION
LAV.
ACCESSIBLE
LAVATORY
9"
M
I
N
.
2'
-
3
"
M
I
N
.
2'
-
5
"
M
I
N
.
1'-5"
6" MAX.8"
2'
-
1
0
"
M
A
X
.
T
O
T
H
E
R
I
M
9"
M
I
N
.
2'
-
3
"
M
I
N
.
1'-5"
MIN.
11" MIN.
8" MIN.
36
"
M
A
X
.
42
"
-
4
8
"
SP
O
U
T
H
G
T
'
S
.
12"
MIN.
4"
M
I
N
.
4'
-
6
"
M
A
X
.
S
I
D
E
A
P
P
R
O
A
C
H
4'
-
0
"
M
A
X
.
F
R
O
N
T
A
P
P
R
O
A
C
H
5'
-
0
"
4'
-
6
"
M
A
X
.
SI
D
E
A
P
P
R
O
A
C
H
3'
-
1
0
"
M
A
X
.
OR
O
B
S
T
R
U
C
T
I
O
N
OV
E
R
C
O
U
N
T
E
R
4'
-
1
0
"
M
A
X
.
FR
O
N
T
A
P
P
R
O
A
C
H
3'
-
4
"
M
A
X
.
TO
R
E
F
L
E
C
T
I
O
N
SU
R
F
A
C
E
3'-0"
MIN.
3'-6"
MIN.
4'-6"
MIN.
3'
-
6
"
M
I
N
.
(4
'
-
0
"
M
I
N
.
W
/
BO
T
H
L
A
T
C
H
&
C
L
O
S
E
R
)
5'
-
0
"
MI
N
.
4'
-
6
"
MI
N
.
2'-0"
MIN.
2'-0"
MIN.
3'
-
6
"
M
I
N
.
(4
'
-
0
"
M
I
N
.
W
/
CL
O
S
E
R
)
4'
-
0
"
M
I
N
.
(4
'
-
6
"
M
I
N
.
W
/
CL
O
S
E
R
)
4'
-
0
"
MI
N
.
5'
-
0
"
MI
N
.
18"
MIN.
12"
MIN.
NOTE: ACCESSIBILITY DETAILS
DESIGNED TO BE IN
ACCORDANCE WITH THE 2010
ADA STANDARDS FOR
ACCESSIBLE DESIGN.
CLEAR FLOOR SPACE AT WATER CLOSET
(FRONT APPROACH)ACCESSIBLE
URINAL
TO RIM
URINAL
TO
CONTROLS
1'
-
5
"
3'
-
8
"
M
A
X
.
NOTE: DETAILS SPECIFIC TO
PROJECT WITHIN BALANCE OF
CONSTRUCTION DOCUMENTS
OVERRIDE DETAILS BELOW
WHERE APPLICABLE.
42" MIN.1'-6"
56
"
M
I
N
.
60" MIN.
CLEAR
FLOOR
SPACE
G.B. 1
G.B. 2
W.C.
CLEAR FLOOR SPACE AT WATER CLOSET
(FRONT APPROACH)
G.B. 1
W.C.W.C.
G.B. 2
T.P.H.
ACCESSIBLE
WATER CLOSET
ACCESSIBLE
WATER CLOSET
33
"
-
3
6
"
19
"
M
I
N
.
17
"
-
1
9
"
1'-6"
33
"
-
3
6
"
17
"
-
1
9
"
3'-0"
MAX.
7"-9"
54" MIN.
2"
M
I
N
.
15
"
MI
N
.
GRAB BAR GRAB BAR
NUMBER LENGTH (<)
GB1 3'-0"
GB2 3'-6"
GB3 1'-6"
G.B. 3
12"12"
G.B. 3
TOWEL
SLOT
P.T.D.
ACCESSIBLE P.T.D.
4'
-
6
"
M
A
X
.
S
I
D
E
A
P
P
R
O
A
C
H
4'
-
0
"
M
A
X
.
F
R
O
N
T
A
P
P
R
O
A
C
H
G.B.
W.C.
LAV.
PL-1
PROVIDE AND INSTALL A.D.A.
COMPLIANT TRAP WRAP
INSULATION (WHITE IN COLOR).
8'
-
0
"
EQ.EQ.
SURFACE
MOUNTED
LIGHT
FIXTURE
4'
-
6
"
3
F
U
L
L
T
I
L
E
S
CUT TILE
IN CORNER
W.C.
G.B.
C3
CASEWORK CABINETRY-
SEE 11/A6.2 FOR DETAILS.
B.O. AT 4'-0" A.F.F.
T1
P4
T1
4'
-
6
"
3
F
U
L
L
T
I
L
E
S
P5
ADD CONCEALED SPACERS
BEHIND MIRROR ABOVE TILE
SO MIRROR IS PLUMB AT TILE
& WALL.
T.P.H.
INSTALL CONCEALED
SPACERS AT VERTICAL
GRAB BAR AS REQ'D.
T.P.H.
MI.
P.T.H.-
ALIGN T.O.
DISPENSER
W/ T.O. TILE
& CENTER
ON TILE
(VFY.).
6"
4'
-
6
"
3
F
U
L
L
T
I
L
E
S
START WITH FULL WALL TILE AT CORNER /
WALL EDGE. VERIFY LOCATIONS WITH PLANS
& ELEVATIONS, TYP.
B4
P4
CUT TILE
VERIFY
F1
P4/P5
VERIFY
TILE JOINTS OF BASE TILE MUST
ALIGN WITH TILE JOINTS ON FLOOR,
TYP.
SATIN ALUMINUM (AE) TILE EDGE
TRIM- SCHLUTER SCHIENE, TYP. AT
ALL EXPOSED TILE EDGES.
SEE PLANS, ELEVATIONS & TOILET ROOM
DETAILS FOR MORE INFORMATION.
SATIN ALUMINUM (AE) TILE EDGE
TRIM- SCHLUTER SCHIENE, TYP. AT
ALL EXPOSED TILE EDGES.
T1
6" HIGH BASE AT TOILET ROOMS.
4" HIGH BASE AT ALL OTHER
LOCATIONS SCHEDULED U.N.O., TYP.
B4
B3
CUT TILE
IN CORNER
START FULL
TILE
START FULL
TILE
109
10
9
A2.2
3
A2.2
2
A2.2
5
T.P.H.G.B.(42")
W.C.
G.B.(36")
P.
T
.
D
.
LAV.
MI.
REV.
1'
-
6
"
3'
-
0
"
±
5'-
0
"
MIN
.
1'
-
6
"
1'-1"
G.B.(18")
(VERT.)
B4
F1
C3
CASEWORK CABINETRY-
SEE 11/A6.2 FOR DETAILS.
B.O. AT 4'-0" A.F.F.
U.S.
JOINTS OF THE BASE FINISH
TO ALIGN WITH THE FLOOR
FINISH, TYP. SEE DETAIL 8/A2.2
FOR MORE INFORMATION.
START WITH FULL FLOOR TILE AT
THE DOOR CORNER, VERIFY.
48"x48"
5"
8'
-
0
"
5"
5"7'-0"7"7'-0"8 1/2"
48"x30"
60"x54"
56"x60"
108
10
8
A2.2
3
A2.2
2
A2.2
5
T.P.H.G.B.(42")
W.C.
G.B.(36")
P.
T
.
D
.
LAV.
MI.
1'
-
6
"
3'
-
0
"
±
5
'
-
0
"
M
I
N
.
1'
-
6
"
1'-1"
G.B.(18")
(VERT.)
B4
F1
C3
CASEWORK CABINETRY-
SEE 11/A6.2 FOR DETAILS.
B.O. AT 4'-0" A.F.F.
U.S.
JOINTS OF THE BASE FINISH
TO ALIGN WITH THE FLOOR
FINISH, TYP. SEE DETAIL 8/A2.2
FOR MORE INFORMATION.
START WITH FULL FLOOR TILE AT
THE DOOR CORNER, VERIFY.
48"x48"
48"x30"
60"x54"
56"x60"
REV.
WALL PARTITION AS
SCHED. SEE A2.0 FOR
ACTUAL WALL
ORIENTATION.
WATER SUPPLY &
WASTE PIPING TO BE
STUBBED AT WALL
LOCATION AS SHOWN
DASHED. PLUMBING
CONTRACTOR TO
COORDINATE FINAL
LOCATIONS W/
FIXTURE CUT SHEETS.
10
3
/
4
"
VF
Y
.
PLAN VIEW DETAIL
ELEVATION VIEW DETAIL
STAINLESS STEEL
DECORATIVE BAR
BELOW.
TEMPERED GLASS
LAVATORY BOWL.
GLASS LAVATORY
SHELF BELOW.
STAINLESS STEEL
FAUCET FIXTURE AS
SCHEDULED.
STAINLESS STEEL
VANITY BELOW.
34
"
M
A
X
.
TO
R
I
M
O
F
B
O
W
L
STAINLESS STEEL
DECORATIVE BAR
BELOW.
TEMPERED GLASS
LAVATORY BOWL.
GLASS LAVATORY
SHELF BELOW.
STAINLESS STEEL
FAUCET FIXTURE AS
SCHEDULED.
PLUMBING CONTRACTOR TO
STUB WATER SUPPLY &
WASTE PIPING AS REQ'D. PER
MFR.'S RECOMMENDATIONS.
COORD. FINAL LOCATIONS
W/ FIXTURE CUT SHEETS.
4"
1'-1"
1
3
/
8
"
8"
PL-1
PL-1
WOOD FRAMED MIRROR AS
SCHEDULED.
4" HIGH PLASTIC LAMINATE
BACKSPLASH .
PLASTIC LAMINATE FINISH
ON VANITY COUNTER .
SEMI-COUNTERTOP SINK-
SEE PLUMBING PLANS.
NOTE: PROVIDE FINISHED
END PANEL AT OPEN END OF
VANITY COUNTER.
PROVIDE A.D.A. COMPLIANT
TRAP WRAP INSULATION
(WHITE IN COLOR).
2'
-
1
0
"
M
A
X
.
T
O
R
I
M
VE
R
I
F
Y
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
N
TOILET ROOM LEGEND
W.C.FLOOR SET TANK STYLE WATER CLOSET. FLUSH CONTROLS TO BE LOCATED ON
ACCESSIBLE SIDE OF FIXTURE. SEE PLUMBING PLANS.
LAV.DROP-IN BOWL STYLE LAVATORY SET IN COUNTERTOP WITH A.D.A. COMPLIANT
FAUCET. PROVIDE AND INSTALL A.D.A. COMPLIANT TRAP WRAP INSULATION
(WHITE IN COLOR). SEE PLUMBING PLANS.
MI.WOOD FRAMED WALL MIRROR. SET WOOD FRAMED MIRROR IMMEDIATELY
ABOVE VANITY BACKSPLASH. REFLECTIVE SURFACE OF MIRROR SHALL BE NO
HIGHER THAN 3'-4" A.F.F. CENTER MIRROR ON LAVATORY SINK.
G.B.STAINLESS STEEL HANDICAP COMPLIANT GRAB BARS PER CODE. LENGTHS NOTED
ON PLAN.
T.P.H.WALL MOUNTED TOILET PAPER HOLDER (MULTI-ROLL). BOBRICK B-2888 SERIES.
P.T.H.SURFACE MOUNTED C-FOLD PAPER TOWEL DISPENSER. BOBRICK B-2620.
U.S.UNISEX TOILET ROOM SIGNAGE. PLASTIC SIGN INDICATING ACCESSIBILITY.
SELF-ADHERED. SEE SHEET A0.3 FOR DETAILS.
LAVATORY NOTE:
LAVATORIES SHALL HAVE A CLEAR ACCESS WIDTH OF NOT LESS THAN 30", CLEAR HEIGHT OF
NOT LESS THAN 29" TO THE BOTTOM OF THE FIXTURE APRON, CLEAR HEIGHT OF NOT MORE
THAN 34" TO THE RIM OF THE FIXTURE, & A CLEAR DEPTH OF NOT LESS THAN 12" UNDER THE
FIXTURE EXCLUSIVE OF THE BOWL & WASTE PIPE. ALL EXPOSED PIPES ARE TO BE COVERED
WITH AN INSULATED PROTECTIVE MATERIAL. THE WATER CONTROL VALVES SHALL HAVE
LEVER HANDLES.
RESTROOM ACCESSORIES NOTE:
ALL FIXTURES & ACCESSORIES TO MEET ACCESSIBILITY REQUIREMENTS, SEE DETAIL 4/A2.2.
MIRRORS SHALL BE MOUNTED SO THAT THE BOTTOM IS NO HIGHER THAN 40" ABOVE THE
FLOOR. ALL WALL-MOUNTED DISPENSERS, WASTE, DISPOSAL CONTAINERS, OR SIMILAR
ACCESSORIES SHALL BE MOUNTED SO THAT WORKING HEIGHT IS NO HIGHER THAN 48"
ABOVE THE FLOOR FOR A FRONT APPROACH AND NO HIGHER THAN 54" ABOVE THE FLOOR
FOR A SIDE APPROACH, AND SHALL BE FREE OF INTERFERENCE BY GRAB BARS OR OTHER
ACCESSORIES OR FIXTURES. GRAB BARS SHALL SUPPORT A WEIGHT OF 250 LBS. OR GREATER.
RESTROOM FINISHES NOTE:
SHALL BE INSTALLED 4'-6" HIGH ON WALLS ADJACENT TO WATER CLOSET. TILE TO BE
INSTALLED IN FULL TILE INCREMENTS STARTING WHERE INDICATED ON ELEVATIONS. ALL
OTHER WALLS TO HAVE A 6" HIGH BASE. SEE DETAIL 8/A2.2.
T1
B4
TOILET ROOM PLAN,
ELEVATIONS &
ACCESSIBILITY
A2.25
A2.2 1 1/2"=1'-0"
VANITY COUNTER DETAIL 6
A2.2 1"=1'-0"
NAIL SINK DETAILS 7
A2.2
NOT USED 8
A2.2 1/2"=1'-0"
TYPICAL TILE LAYOUT DETAIL
4
A2.2 1/4"=1'-0"
ACCESSIBILITY DETAILS3
A2.2 1/2"=1'-0"
TOILET ROOM ELEVATION
2
A2.2 1/2"=1'-0"
TOILET ROOM ELEVATION
1
A2.2 1/2"=1'-0"
ENLARGED TOILET ROOM PLAN
PEDI-SPA
BY SALON LOFTS.
F6
18"
MIN.
1'
-
0
"
HUB DRAIN (LOCATE AS FAR TO THE
REAR OF THE PEDISPA AS POSSIBLE
BUT STILL TO BE CONCEALED) - SEE
PLUMBING PLANS.
VERIFY OUTLET LOCATION
WITH ELECTRICAL PLANS.
2'
-
0
"
EXHAUST GRILLE IN WALL- PAINT
TO MATCH WALL. VFY. LOCATION
W/ SHEET A2.0 & MECH PLANS.
LOCATE WATER LINES &
OUTLETS IN WALL.
WATER STUBS TO BE
ELECTRICALLY BONDED.
GRID GRID
GRID
GRID
01020305
04
06
07
107
08
0910
108109
111
11
12
14
15
13
16
17 19
18 20
21
22 23 24
25
101
102103
104
105
106
110
112
113
114
FE
FE
FE
C7
F8
C12
C11
C10
F5
F4
F7
F20
F6
F3
C14
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
F19
C9C3
C15
F12
F23
C3
C4
C2 C16
F14
C2
F1
C1 C5
C3
C4
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3 C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3
C4
C2 C16
F14
C2
F1
C1 C5
C3
C4
C3
C4
C2C16
F14
C2
F1
C1C5
C3
C4
C3
C4
C2 C16
F14
C2
F1
C1 C5
C3
C4
C3
C4
C2 C16
F14
C2
F1
C1 C5
C3
C4
C3
C4
C2 C16
F14
C2
F1
C1 C5
C3
C4
C3
C4
C2 C16
F14
C2
F1
C1 C5
C3
C4
C3
C4
C2 C16
F14
C2
F1
C1 C5
C3
C4C5
C2
C3
C4
C1F1
C16
F14 C2
C3
C4
C5
C2
C3
C4
C1F1
C16
F14 C2
C3
C4
C5
C2
C3
C4
C1F1
C16
F14
C2
C3
C4
C5
C2
C3
C4
C1F1
C16
F14
C2
C3
C4
C5
C2
C3
C4
C1 F1
C16
F14
C2
C3
C4
C5
C2
C3
C4
C1 F1
C16
F14
C2
C3
C4
F19
C9C3
C15
C7
F8
C14
F23
F21 F21
F22
F9
F9
F9
F9
F10
C13
F5
C17
C5HORIZ.
C5HORIZ.
C5VERT.C5HORIZ.
F12F12
F12
F12
F12
F10
F9F9
F12
F12
F12
F12 F12 F12
F12
F12 F12
F12HORIZ.
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
FURNITURE PLAN
A2.32
A2.3 1/2"=1'-0"
PEDI-SPA SECTION DETAIL
N
1
A2.3 3/16"=1'-0"
FURNITURE PLAN
SATIN ALUM. (AE) TILE
EDGE TRIM -
SCHLUTER-SCHIENE.
CARPET OVER
SELF-LEVELING
CEMENTITIOUS
UNDERLAYMENT.
ALIGN/FLUSH
F1/F7VARIES
ADA COMPLIANT FLUSH ALUM. THRESHOLD RAMP BY
PEMKO OR APPROVED EQ. VERIFY FINAL ELEVATION
OF CERAMIC TILE PRIOR TO ORDERING THRESHOLD
SO AS TO MAKE A FLUSH TRANSITION.
F1/F7
DOOR THRESHOLD /
BUILDING EXTERIOR
(VERIFY)
GRID GRID
GRID
GRID
01020305
04
06
07
107
08
0910
108109
111
11
12
14
15
13
16
17 19
18 20
21
22 23 24
25
101
102103
104
105
106
110
112
113
114
FE
FE
FE
CARPET TILE LAYOUT STARTING POINTS
(SHOWN SHADED) ARE AS DIMENSIONED
AT HALLWAYS '102' & '104'.
T1
/
P
5
P4
F1
B4
T1/P4
TYP. @
EDGES
F1
NOTE: GENERAL CONTRACTOR SHALL VERIFY SALON LOFTS SUPPLIED FINISH
MATERIAL QUANTITIES AS INDICATED ON SHEET A0.3 WITHIN 7 DAYS
OF BEING AWARDED THE CONTRACT FOR CONSTRUCTION. SUBMIT
FINAL VERIFIED QUANTITIES TO SALON LOFTS' REPRESENTATIVE.
GENERAL CONTRACTOR ASSUMES RESPONSIBILITY FOR CHARGES
RELATED TO FINISH MATERIAL SHORTAGES WHICH ANY/ALL WERE NOT
VERIFIED & COORDINATED WITH SALON LOFTS' REPRESENTATIVE
WITHIN THE TIME FRAME NOTED.F6
B1
P1
F1
B1
P1
F4
T1
3 TYP.
A2.4
2
A2.4
3
6"
6"6"6"4"T1
P7/P1P7/P1P7/P1
P7/P1 P7/P1
P7
/
P
1
P7
/
P
1
P7/P1 P7/P1 P7/P1 P7/P1 P7/P1 P7/P1
T1
T1
P7
/
P
1
P7/P1P7/P1P7/P1P7/P1
P7
P7
/
P
1
P7
/
P
1
P7/P1 P7/P1
P7
/
P
1
P7/P1 P7/P1 P7/P1
P6
P6P6
5555
6
5
5
5
P6
P6
P6
P6
5
P6
5
P6
5
P6
5
P6
5
P6
5 P6
5
5
P6
P6
5
P6
5
P6
5
P6
5
5
P6
P6P6
5 5
P6
5
4"11 1/2"4'-0"2'-0"2'-0"2'-0"4"
1'
-
1
"
11
"
11
'
-
6
3
/
4
"
2'
-
0
"
1'
-
6
"
4"
2'
-
0
"
1'
-
6
"
4"
4"
TYP.1'-8 1/2"2'-0"12'-0"1'-9"2'-0"1'-6"4"
4"
1'
-
6
"
4'
-
0
"
12
"
4"
F3
F3
F2
F2
1'
-
6
3
/
4
"
F2
1'
-
5
1
/
4
"
4"
2'
-
0
"
1'
-
6
"
4"
55
4
1'
-
1
0
1
/
2
"
1'-2"
4"2'-0"1'-6"4"
11
2
1 1
4"
1'
-
6
"
1'
-
1
0
"
4"
1
2
1
22
212
1
22
4"
TY
P
.
A6.4
4
A6.4
4
A2.4
2
4"
P4
F1
B4
F1
B1
P1
F1
B1
P1
F1
B1
P1F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F1
B1
P1
F6
B1
P1
F6
B1
P1
TYP. @
EDGES
F1
TYP. @
EDGES
F1
T1
/
P
5
T1/P4
F7
F2
F1
F2
F1
TYP. @
VESTIBULE
PERIMETER3TYP.
3 TYP.3 TYP.3 TYP.
3 TYP.
8 TYP.
8 TYP.
8 TYP.7 TYP.
7 TYP.
7 TYP.
9
9 TYP.9 TYP.9 TYP.
9 TYP.
9 TYP.
F5
B2
P1
2
F2
1010
22
7
TYP.
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
FINISH FLOOR PLAN
A2.4
1
A2.4 3/16"=1'-0"
FINISH FLOOR PLAN
N
FINISH KEY NOTES
1
2
3
4
FULL 24x24 CARPET TILE.
PARTIAL CARPET TILE TO DIMENSIONS INDICATED. CUT TILE
AS REQ'D. TILES WITHOUT STRAIGHT AND TRUE EDGES
SHALL NOT BE ACCEPTED.
BELOW 9'-6" A.F.F, WALL TO BE PAINTED PER PLANS. ABOVE
9'-6" A.F.F., WALL TO BE PAINTED , TYP.
TILE JOINTS OF THE TILE BASE MUST ALIGN WITH THE TILE
FLOOR JOINTS, TYP. SEE DETAIL 8/A2.2.
START WITH FULL TILE AT DOOR ENTRY, SHOWN HATCHED.
ALL OTHER TILE WITHIN ROOM BASED ON THIS START POINT.
FLOORING EXTENDS TO SPA VESTIBULE THROUGH
DOOR #107 TO ABUT FLOOR AT THRESHOLD.
4" CUT TILE FLOOR , TYPICAL AT HALLWAY PERIMETER.
TILE JOINTS AT HALLWAY PERIMETER TILE DO NOT
NECESSARILY ALIGN W/ JOINTS WITHIN LOFTS. SEE DETAIL
3/A2.4 FOR TYP. TRANSITION.
AT CORNERS, TILE TO BE BUTT JOINTED AS INDICATED
WITH THE SCHLUTER STRIP MITRED AND TIGHTLY JOINED SO
THERE IS NO GAP. TOP OF SCHLUTER STRIPS FORMING
CORNERS TO BE FLUSH.
P.LAM. WINDOW SILL SUPPLIED & INSTALLED BY G.C.
PAINT ALL EXPOSED SIDES OF GYP. BD. COLUMN ENCLOSURE
TO 9'-6" A.F.F. PAINT EXPOSED STEEL COLUMN
ABOVE 9'-6" A.F.F. .
P2
5
6
7
F2
F6
1.FINISH ABOVE 9'-6" (VFY.) @ INTERIOR WALLS TO BE
. SEE DETAIL 4/A6.3, TYP.
2.ALL GYP. BD. WALL/CEILING SOFFITS WITHIN CONSTR.
AREA TO RECEIVE A SMOOTH PAINT FINISH, U.N.O.
3.ALL GYP. BD. WALL SURFACES TO BE FINISHED
SMOOTH REGARDLESS OF FINISHES SCHEDULED.
4.G.C. TO PROVIDE SMOOTH FLOOR TRANSITIONS
BETWEEN FINISHES SCHEDULED, FLASH SLAB, ETC. AS
REQ'D.
5.G.C. TO APPLY PAINT AS REQ'D. PER MFR.'S
SPECIFICATIONS. TWO COATS OF FINISH PAINT TO BE
PROVIDED OVER PRIME COAT AT NEW
CONSTRUCTION OR EXIST. PAINT AT EXIST. CONSTR.
6.TOUCH-UPS MAY REQUIRE REPAINTING ENTIRE
SURFACE UNTIL CHANGE OF PLANE OCCURS IF VISIBLE.
7.G.C. TO PROVIDE A PROTECTIVE COATING AT ALL NEW
FLOOR FINISHES AFTER INSTALLATION.
8.ALL FLOORING FINISHES SHALL BE OF CLASS I OR
CLASS II MATERIALS IN ACCORDANCE WITH NFPA 253
AND INTERNATIONAL BUILDING CODE 804.1. TEST
REPORT COPIES TO BE PROVIDED TO BLDG. OFFICIAL
UPON REQUEST.
9.ALL INT. WALL, CEILING, & FLOOR FINISHES SHALL BE
CLASS B OR CLASS C.
CLASS B: FLAME SPREAD 26-75; SMOKE
DEVELOPED 0-450
CLASS C: FLAME SPREAD 76-200; SMOKE
DEVELOPED 0-450
10.ALL INTERIOR FINISHES TO BE ATTACHED SUCH THAT
MATERIALS WILL NOT SEPARATE FROM SUBSTRATE
WHEN SUBJECTED TO A ROOM TEMPERATURE OF
200°F FOR NOT LESS THAN 30 MINUTES.
11.SITE SURVEY REQUIRED BY FLOORING INSTALLER
PRIOR TO BID. ALL FLOOR PREP SHALL BE INCLUDED IN
THE BASE BID FOR THE PROJECT.
12.FULLY ADHERE CARPET TILES & BROADLOOM CARPET
W/ MFR. RECOMMENDED ADHESIVE. NO ADHESIVE
SHALL BE PLACED PAST EDGE OF CARPET TILES ONTO
ADJACENT FLOOR SURFACE. THE 4" WIDE TYPICAL
EXPOSED FINISH BETWEEN CARPET & WALL
SHALL BE COMPLETELY FREE OF EXCESS ADHESIVES.
13.PAINT SYSTEMS: PROVIDE MIN. (2) COATS PLUS
PRIMER SYSTEMS.
A) GYPSUM BOARD WALLS (HALLWAYS):
EGGSHELL LATEX EMULSION
B) GYPSUM BOARD WALLS (LOFTS, TOILET RMS,
UTILITY):
EGGSHELL LATEX EMULSION
C) INTERIOR PAINTED METAL:
SEMI-GLOSS 100% ACRYLIC
D) GYPSUM BOARD CEILINGS:
FLAT LATEX EMULSION
E) OPAQUE PAINTED WOOD:
SEMI-GLOSS 100% ACRYLIC
F) EXTERIOR PAINTED METAL:
SEMI-GLOSS 100% ACRYLIC
G) EXPOSED STRUCTURE CEILINGS, DUCTWORK,
STRUTS, CONDUITS, WIRES, ETC:
WATERBORNE ACRYLIC FLAT DRYFALL
PRIMER/FINISH (ONE COAT SYSTEM)
P2
FINISH GENERAL NOTES
F1
PL-1
8
9
F1
F1
3
A2.4 6"=1'-0"
CARPET-TILE TRANSITION2
A2.4 6"=1'-0"
THRESHOLD DETAIL
10
P1
P2
GRID
L
L
N
MM
A
AA
A
A
A
A
A A A A A A
A
A
A
AAA
A A A
BF
F
BF
F
BF
F
BF
F
BF
F
BF
F
BF
F
F
F
B F
F
B F
F
B
F
F
B
F
F
B
F
F
B F
F
B F
F
B
F
F
B
FF
B
FF
B
FF
B
FF
B
FF
B
FF
B
E
C2 C2
C2 C2
C2 C2
H (4'L)
J
X-2
DDDD
DDD
DDD
D
C1C1
KK
G
X-1
X-
1
X-
1
X-1
EM2
EM
2
X-
1
X-
1
X-1
X-
1
X-
1
X-1
X-2
X-
2
X-2
X-2
X-
2
GRID
GRID
GRID
GGG
X-1
X-1
X-2
X-
2
J
X-1
H (4'L)H (1'L)H (4'L)H (1'L)
E
C2 C2
C2 C2
J
1'-11"2'-1"2'-1"
01020305
04
06
07
107
08
0910
108109
111
11
12
14
15
13
16
17 19
18 20
21
22
23
25
101
102
103
104
105
106
110
112
113
114
12
"
5'
-
1
"
A6.4
5
6"
8"
4'
-
7
"
5'
-
3
"
6"
6"3'-4 1/4"4'-0 1/4"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
5'-1"12"
2'
-
1
"
2'
-
1
"
1'
-
1
1
"
5'-1"12"
2'
-
1
"
2'
-
1
"
1'
-
1
1
"
5'-1"12"
2'
-
1
"
2'
-
1
"
1'
-
1
1
"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
6"
R2'-9"
EQ.EQ.
EQ
.
EQ
.
EQ.EQ.
EQ
.
EQ
.
EQ.EQ.
EQ
.
EQ
.
3'-6"3'-6"3'-6"3'-6"
1'
-
6
"
2'
-
6
"
2'
-
6
"
1'
-
6
"
1'
-
6
"
2'
-
6
"
2'
-
6
"
1'
-
6
"
2'
-
1
0
"
4'
-
3
"
5'-3"5'-3"
1'-11"2'-1"2'-1"
2'-1"2'-1"1'-11"
12
"
4'
-
4
"
12
"
5'
-
1
"
1'-11"2'-1"2'-1"
12
"
5'
-
1
"
2'-1"2'-1"1'-11"
5'
-
1
"
12
"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'
-
1
1
"
2'
-
1
"
2'
-
1
"
12"5'-1"
1'-11"2'-1"2'-1"
12
"
5'
-
1
"
A6.4
5
SIM.
NOTE:
PROVIDE ADDITIONAL
CONCEALED BRACING TO ROOF
STRUCTURE FROM FLOATING
GYP. BD. CEILING IN ENTRY TO
RESIST POSSIBLE UPLIFT /
MOVEMENT FROM WIND
PRESSURE.
9'-0"
A.F.F.
P3
2
4
9'-0"
A.F.F.
P3
2
6
9
6"
2'
-
6
"
2'
-
6
"
6"
6"2'-9"2'-1"8"6"
6'
-
5
3
/
8
"
6'
-
5
3
/
8
"
R1'
-
9
"
6"EQ.EQ.
R2'-
9
"
2'-3"7'-6"16'-11 3/4"2'-1"
2'
-
1
"
11
'
-
1
0
1
/
2
"
2'
-
1
"
2'-1"18'-8"16'-3"2'-1"
5'
-
8
"
14
'
-
1
1
/
2
"
11
'
-
1
1
/
2
"
ALIGN
ALIGN
EQ.
TYP.
EQ.
TYP.
4'-2"4'-4"3'-3 1/2"4'-4"6"
EQ.
TYP.
EQ.
TYP.
EQ
.
TY
P
.
EQ
.
TY
P
.
4'-7"16'-0"16'-0"8'-6"8'-10"
EQ
.
TY
P
.
EQ
.
TY
P
.
EQ
.
TY
P
.
EQ
.
TY
P
.
A6.4
5
A6.4
5
R2'-3"R2'-3"
9'-0"
A.F.F.
P3
2
9'-0"
A.F.F.
P3
2
7'-9 3/4"15'-0"15'-0"15'-0"
EQ
.
EQ
.
9'-0"
A.F.F.
P3
113OPEN TO
DECK, TYP.
3 OPEN TO
DECK, TYP.
P2
3 OPEN TO
DECK, TYP.
P2
3 OPEN TO
DECK, TYP.
P2
9'-0"
A.F.F.
ACT-1
9'-0"
A.F.F.
ACT-1
11
11 11
11
11
7 6 6 7
6
6
7
6
7
8
5
5
10
12
6 TYP.
6 TYP.
9"
1'
-
3
"
2'-7"
2'
-
6
"
2'-7"
2'
-
6
"
2'-7"
2'
-
6
"
2'-9"
2'
-
6
"
2'-11"
2'
-
6
"
2'
-
5
"
3'-4"
3'
-
2
"
2'-6"
1'-7"
3'
-
2
"
4'
-
4
"
2'
-
1
0
"
13"
2'
-
1
0
"
3'-9"
3'
-
9
"
3'
-
9
"
3'
-
9
"
9'-5 3/4"
2'-5"
5'
-
1
0
1
/
2
"
1'
-
6
"
2'-1"
10 1/2"
7'-6"
6 TYP.
3'-10"
3'-10"
3'-10"
1'
-
5
"
6 TYP.
6 TYP.
6 TYP.
6
8"
8
4
6'-7 1/2"4'-6"
3 OPEN TO
DECK, TYP.
P2
NO WORK
REQ'D.
NO WORK REQ'D.
14
6"
6'
-
1
"
7"
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
REFLECTED CEILING
PLAN
A3.0
1
A3.0 3/16"=1'-0"
REFLECTED CEILING PLAN
N
EM2
REFLECTED CEILING GENERAL NOTES
1.REFER TO ENGINEERING DRAWINGS FOR ELECTRICAL, LIGHTING AND HVAC WORK. COORDINATE ANY
DISCREPANCIES WITH OWNER'S REPRESENTATIVE.
2.BACK TO BACK SWITCHES ARE NOT ALLOWED. OFFSET A MINIMAL DIMENSION WITH A METAL STUD IN BETWEEN
OPPOSING SWITCHES OR HAVE ONE SET LOW/ONE HIGH. SEE ELECTRICAL PLANS.
3.SWITCHES SHOWN IN THE SAME LOCATION SHALL BE GANGED ON THE SAME COVER PLATE.
4.COORD. W/ ALL TRADES TO ENSURE CLEARANCES FOR ALL CEILING RELATED APPURTENANCES NECESSARY TO
MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT AS NOTED ON THE DRAWINGS. FIELD VERIFY PRIOR TO BID.
5.ALL LIGHT FIXTURES, HVAC EQUIP. & DIFFUSERS TO BE SUPPORTED FROM TOP CHORD OF STRUCT. JOIST ABOVE.
6.HANGER WIRE AT SUSPENDED CEILING (WHEN APPLICABLE) SHALL BE 8 GA., AND 10 GA. AT SUSPENDED A.C.T.
WIRES SHALL BE ATTACHED TO STRUCT. STEEL ONLY, WITH U.L. LISTED CLAMPS. DO NOT ATTACH SUPPORT WIRES
TO MECH. EQUIPMENT OR PIPING. SCREWS ARE NOT PERMITTED IN THE METAL DECKING.
7.CLG. SUSP. SYSTEM (AS REQ'D.) SHALL BE ATTACHED AT 2 ADJACENT WALLS, MAINTAIN 2 SIDES UNRESTRAINED.
8.PROVIDE ACCESS PANELS AS REQ'D. BY CODE. COORDINATE LOCATION W/ ARCHITECT. PROVIDE CEILING ACCESS
TO ALL LANDLORD EQUIPMENT, CONTACT LANDLORD FOR REQUIREMENTS. REVIEW CEILING ACCESS
REQUIREMENTS WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION OF ACCESS PANELS. COORDINATE
ACCESS PANEL REQUIREMENTS WITH GATE SUPPLIER WHERE APPLICABLE.
9.REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE AND SPECIFICATIONS.
10.ALL CEILING HEIGHTS INDICATED ON PLANS ARE FROM TOP OF FINISH FLOOR TO UNDERSIDE OF FINISH CEILING.
11.ARCH. DRAWINGS DETERMINE THE LOCATION OF LUMINARIES & SUPERSEDES ALL OTHER DRAWINGS U.N.O.
12.ADDITIONAL HANGARS AND SAFETY WIRES FOR LIGHT FIXTURES, SPEAKERS AND AIR SUPPLY/RETURN DIFFUSERS
(PER LOCAL CODES) TO BE THE RESPONSIBILITY OF THE CEILING SUB-CONTRACTOR.
13.ALL MEASUREMENTS ARE TO THE CENTER OF THE FIXTURE U.N.O.
14.ALL SPRINKLER HEADS IN FLOATING GYP. BD. CEILINGS TO BE WHITE CONCEALED TYPE, TYPICAL.
REFLECTED CEILING PLAN KEY NOTES
1
2
3
4
5
6
P2
PAINTED SUSPENDED GYP. BD. CEILING (HGT. AS INDICATED)
FLOATING GYP. BD. CEILING AS DIMENSIONED SUPPORTED FROM
STRUCTURE ABOVE. SEE DETAIL 5/A6.4.
OPEN TO DECK, TYPICAL UNLESS NOTED OTHERWISE .
RECESSED JUNCTION BOX ABOVE VESTIBULE CLG. FOR CARD READER
CONTROLLER SYSTEM TO INCLUDE: CONCEALED CONDUIT FROM 'J' BOX
TO ROOF DECK ABOVE, CAT 5E CABLE FROM 'J' BOX TO TENANT'S
NETWORK HUB DEVICE, AND 120V POWER. ALL TO BE PROVIDED BY
ELECT. CONTRACTOR. G.C. SHALL COORDINATE WITH TENANT'S SECURITY
VENDOR THEIR INSTALLATION AFTER ELECT. CONTRACTOR'S WORK IS
COMPLETE. CONTACT SALON LOFTS FOR VENDOR.
G.C. SHALL COORDINATE WITH TENANT'S MUSIC SYSTEM VENDOR FOR
THEIR INSTALLATION. CONTACT SALON LOFTS FOR VENDOR.
HVAC SUPPLY AIR DIFFUSER IN CEILING SYSTEM, SEE MECH. PLANS.
COORD. FINAL LOCATIONS W/ LIGHTING, EXIST. STRUCT., & ACT. CLG.
SYSTEM. CONTACT ARCH. IMMEDIATELY IF ANY DISCREPANCIES ARISE.
EXHAUST FAN IN CEILING SYSTEM, SEE MECHANICAL PLANS.
DOOR CHIME LOCATED ABOVE LIGHT COVE IN WAITING AREA #103 &
HALLWAY #114.
RECESSED GRAPHIC WITH HEAD ILLUMINATION. SEE 3/A6.1.
ILLUMINATED SALON LOFTS PUCK & GRAPHIC PANEL WITH LED FLEX
LIGHTS. G.C. TO COORDINATE REQUIREMENTS.
SKYLIGHT AS INDICATED ON SHEET A1.1. PROVIDE UNI-STRUT &
HANGERS FROM BOTTOM OF ROOF STRUCTURE TO SUSPEND LIGHTING
WHERE NEW SKYLIGHTS ARE LOCATED, IF NECESSARY.
InterlockingRock PANEL WALL WITH HEAD ILLUMINATION. SEE DETAIL
6/A6.4.
OPEN TO DECK - NO FINISH REQUIRED THIS SPACE.
SEE DETAIL 6/A6.4 FOR DETAIL AT FLOATING GYP. BD. CEILING EDGE,
LIGHT FIXTURE, & InterlockingRock PANELS.
LIGHT FIXTURE SCHEDULE
NOTE: REFER TO ELECTRICAL DRAWINGS FOR FIXTURE & LAMPING SPECIFICATIONS.
NOTE: CONTRACTOR IS RESPONSIBLE FOR ALL MOUNTING MEANS & METHODS, INCLUD. ALL APPROPRIATE BLOCKING.
G
K
C1
F
D
X-1
PENDANT LIGHT FIXTURE W/ SHADE & WHITE CORD
WHIP. CONTRACTOR TO PROVIDE & INSTALL WHITE
CORD CAP- BOTTOM OF FIXTURE @ 7'-4" A.F.F.
(NOTE: MOGUL ADAPTOR SHALL BE INSTALLED
TIGHT TO B.O. THE TOP OF THE SHADE FRAME)
4'-0" TRACK W/ 3 LED HEADS. SUSPEND FROM
STRUCT. ABOVE WITH SUPPORT & POWER FEED
PENDANT MOUNTINGS PROVIDED. INSTALL TRACK
@ 9'-0" A.F.F.
RECESSED FLUORESCENT DOWNLIGHT WITH
EMERGENCY BATTERY PACK.
RECESSED MINI LOW VOLTAGE DOWNLIGHT-
DIMMABLE
12" METAL HALIDE SUSPENDED DOWNLIGHT. B.O.
FIXTURE @ 9'-6" A.F.F. (COORDINATE W/ EXISTING
STRUCTURE HEIGHTS)
2'-0" x 4'-0" FLUORESCENT INDIRECT LAY-IN TYPE
LIGHT FIXTURE WITH EMERGENCY BATTERY PACK.
3'-6" FLUORESCENT WALL FIXTURE. SURFACE
MOUNTED VERTICALLY ADJACENT TO MIRROR @
5'-10" A.F.F. TO CENTERLINE OF FIXTURE.
SUSPENDED 1'-0" x 4'-0" FLUOR. LIGHT FIXTURE W/
EMERGENCY BATTERY PACK- CHAIN HANG FROM
STRUCT. @ 10'-0"A.F.F.
LED LINEAR WALL WASH FIXTURE. SEE DETAILS
3/A6.1 & 6/A6.4.
DISPLAY W/ LINEAR LED FLEX. SEE 3/A4.2 & 5/A6.3.
2-6" FLUORESCENT WALL FIXTURE. SURFACE
MOUNTED HORIZONTALLY ABOVE MIRROR @
8'-0" A.F.F. TO CENTERLINE OF FIXTURE.
5'-0"Ø AIRCRAFT CABLE 4-POINT SUSPENDED
FLUORESCENT FIXTURE. B.O. FIXTURE @ 9'-0" A.F.F.
4'-0"Ø AIRCRAFT CABLE 4-POINT SUSPENDED
FLUORESCENT FIXTURE. B.O. FIXTURE @ 9'-0" A.F.F.
3'-0"Ø AIRCRAFT CABLE 4-POINT SUSPENDED
FLUORESCENT FIXTURE. B.O. FIXTURE @ 9'-0" A.F.F.
DECORATIVE OUTDOOR EMER. LIGHTING. COORD.
MOUNTING HEIGHTS W/ LOCAL FIRE MARSHALL.
LED EXIT DIRECTION AL LIGHT. COORDINATE
MOUNTING HEIGHTS WITH LOCAL FIRE MARSHALL.
FULLY WALL RECESSED COMPACT HALOGEN EMER.
LIGHT. MOUNT AS INDICATED ON PLAN & ELEV.
B
L
A
X-2
C2
N
E
7
8
9
10
11
M
12
H
J
13
14
A6.1
1
MIRROR
T1
TILE TO ALUM.
FRAME JOINT
SHALL BE CAULKED
(NOT GROUTED)
W/ CAULK TO
MATCH GROUT.
ALUM./GLASS
DOOR FRAME.
A6.1
2
T1
ABOVE
DOOR IN
VESTIBULE.
T1
LINE OF TOP OF
WALL BEYOND
ABOVE
DOOR IN
VESTIBULE.
LINE OF TOP OF
WALL BEYOND
FULL TILE
SEE ELEVATION 9/A4.2 FOR MORE INFORMATION
+0'-0" A.F.F.
FINISH FLOOR
B.O. ROOF DECK
FIELD VERIFY
THREADED ROD &
UNI-STRUT SUPPORTS
FOR FLOATING GYP. BD.
CEILING TO BE PAINTED
, SEE DETAIL
5/A6.4.
LIGHT PER SCHED.
P2
TYP.
MIRROR SET
FLUSH WITH
WALL TILE.
TILE TO ALUM.
FRAME JOINT SHALL
BE CAULKED (NOT
GROUTED) W/ CAULK
TO MATCH GROUT.
ALUM./GLASS
DOOR FRAME.
A6.1
2
FULL TILE
T1
LINE OF TOP OF WALL
BEYOND
ABOVE DOOR
IN VESTIBULE.
T1
A2.0
3
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
LIGHT PER SCHED.
P2
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
A2.0
3
P2
TYP.
EXISTING GYP. BD.
SURFACE UP TO
DECK. PATCH &
REPAIR AS REQ'D.
TO RECEIVE NEW
FINISHES SCHED.
P2
P1
/
P
6
VE
R
I
F
Y
A6.3
4
WALLS TO BE PTD.
PER PLANS. SEE
SHEET A2.4, TYP.
B1
P2TYP.TYP.
B1
P1
TYP.
9'
-
6
"
VE
R
I
F
Y
VE
R
I
F
Y
RECESSED LIGHT
COVE SHOWN
DASHED.
WALL
GRAPHIC
BY SALON
LOFTS
T1
BEYOND ABOVE
DOOR
A6.1
2
ALUM./GLASS STOREFRONT
ENTRY SYSTEM BEYOND
WITH DOOR.
START TILE W/ FULL
HEIGHT TILE @ FLOOR, TYP.
T1
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
SEE ELEVATION 7/A4.2 FOR MORE INFORMATION
MILLWORK DISPLAY WALL
W/ LED/LCD DISPLAY, ALL
INSTALLED BY G.C.
P1
B1
TYP.
P1
P7
B1
TYP.
TYP.P1
P7
B1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
P2BEYOND P2
BEYOND
P2
BEYOND
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P2BEYOND
P2BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
TYP.A6.3
4
RECESSED FIRE
EXTINGUISHER CABINET-
CENTERED ON WALL.
C5
WOOD FRAMED GLASS
MIRROR (VERT.)-
CENTER ON WALL.
3'
-
0
"
BO
T
T
O
M
OF
F
R
A
M
E
FULL
TILE
3 FULL TILESEQ.EQ.
9'
-
0
"
CE
I
L
I
N
G
H
T
.
I
N
V
E
S
T
I
B
U
L
E
FU
L
L
TI
L
E
4
F
U
L
L
T
I
L
E
S
FU
L
L
TI
L
E
PA
R
T
I
A
L
TI
L
E
FULL
TILE
3 FULL TILES EQ.EQ.
9'
-
0
"
CE
I
L
I
N
G
H
T
.
I
N
V
E
S
T
I
B
U
L
E
FU
L
L
TI
L
E
4
F
U
L
L
T
I
L
E
S
FU
L
L
TI
L
E
PA
R
T
I
A
L
TI
L
E
END WALL OF
HALLWAY # 104
BEYOND
END WALL OF
HALLWAY #105
BEYOND
END WALL OF
HALLWAY #102
BEYOND
END WALL OF
HALLWAY #114
BEYOND
END WALL OF
HALLWAY #104
BEYOND
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
WOOD FRAMED GLASS
MIRROR (HORIZ.)
BEYOND- CENTERED ON WALL.
C13
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
3'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
1'-6"1'-6"
4 FULL TILES
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
6'
-
4
"
VE
R
I
F
Y
2'
-
8
"
VE
R
I
F
Y
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
TYP.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
SPA LOFT WALL UP
TO DECK.
P1
B1
P7
TYP.
HVAC DUCTWORK
HUNG FROM B.O.
STRUCT. SEE MECH.
PLANS FOR FINISH &
HANGING METHODS.
TYP.A6.3
4
M25InterlockingRock BLOCK BEYOND.
PAINT (FLAT).
RECESSED EMER. LIGHT
FIXTURE IN WALL. PAINT
COVER TO MATCH WALL.
6"
MILLWORK DISPLAY WALL W/ LED/LCD
DISPLAY, ALL INSTALLED BY G.C.
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
T1
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
TYP.A6.3
4
HVAC DUCTWORK HUNG
FROM B.O. STRUCT. SEE
MECH. PLANS FOR FINISH
& HANGING METHODS.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
TYP.A6.3
4
TILE EDGE RETURNS
(1) FULL TILE WIDTH.
HVAC DUCTWORK
HUNG FROM B.O.
STRUCT. SEE MECH.
PLANS FOR FINISH &
HANGING METHODS.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
TYP.A6.3
4
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
T1
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
SPA LOFT WALL
UP TO DECK.
6"
HVAC DUCTWORK
HUNG FROM B.O.
STRUCT. SEE MECH.
PLANS FOR FINISH &
HANGING METHODS.
RECESSED EMER. LIGHT
FIXTURE IN WALL. PAINT
COVER TO MATCH WALL.TYP.
A6.3
4
A6.4
3
A6.4
3
SIM.
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P1
B1
P7
TYP.
DOOR TRACK OVERHANGS
TILE. DO NOT ATTACH
THROUGH TILE.
P3
END OF InterlockingRock
BLOCK WALL. (FLAT).P3 P3
A6.1
1
MIRROR
T1
TILE TO ALUM.
FRAME JOINT
SHALL BE CAULKED
(NOT GROUTED)
W/ CAULK TO
MATCH GROUT.
ALUM./GLASS
DOOR FRAME.
A6.1
2
T1
ABOVE
DOOR IN
VESTIBULE.
T1
LINE OF TOP OF
WALL BEYOND
ABOVE
DOOR IN
VESTIBULE.
LINE OF TOP OF
WALL BEYOND
FULL TILE
SEE ELEVATION 9/A4.2 FOR MORE INFORMATION
+0'-0" A.F.F.
FINISH FLOOR
B.O. ROOF DECK
FIELD VERIFY
THREADED ROD &
UNI-STRUT SUPPORTS
FOR FLOATING GYP. BD.
CEILING TO BE PAINTED
, SEE DETAIL
5/A6.4.
LIGHT PER SCHED.
P2
TYP.
MIRROR SET
FLUSH WITH
WALL TILE.
TILE TO ALUM.
FRAME JOINT SHALL
BE CAULKED (NOT
GROUTED) W/ CAULK
TO MATCH GROUT.
ALUM./GLASS
DOOR FRAME.
A6.1
2
FULL TILE
T1
LINE OF TOP OF WALL
BEYOND
ABOVE DOOR
IN VESTIBULE.
T1
A2.0
3
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
LIGHT PER SCHED.
P2
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
A2.0
3
P2
TYP.
EXISTING GYP. BD.
SURFACE UP TO
DECK. PATCH &
REPAIR AS REQ'D.
TO RECEIVE NEW
FINISHES SCHED.
P2
P1
/
P
6
VE
R
I
F
Y
A6.3
4
WALLS TO BE PTD.
PER PLANS. SEE
SHEET A2.4, TYP.
B1
P2TYP.TYP.
B1
P1
TYP.
9'
-
6
"
VE
R
I
F
Y
VE
R
I
F
Y
RECESSED LIGHT
COVE SHOWN
DASHED.
WALL
GRAPHIC
BY SALON
LOFTS
T1
BEYOND ABOVE
DOOR
A6.1
2
ALUM./GLASS STOREFRONT
ENTRY SYSTEM BEYOND
WITH DOOR.
START TILE W/ FULL
HEIGHT TILE @ FLOOR, TYP.
T1
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
SEE ELEVATION 7/A4.2 FOR MORE INFORMATION
MILLWORK DISPLAY WALL
W/ LED/LCD DISPLAY, ALL
INSTALLED BY G.C.
P1
B1
TYP.
P1
P7
B1
TYP.
TYP.P1
P7
B1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
P2BEYOND P2
BEYOND
P2
BEYOND
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P2BEYOND
P2BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
TYP.A6.3
4
RECESSED FIRE
EXTINGUISHER CABINET-
CENTERED ON WALL.
C5
WOOD FRAMED GLASS
MIRROR (VERT.)-
CENTER ON WALL.
3'
-
0
"
BO
T
T
O
M
OF
F
R
A
M
E
FULL
TILE
3 FULL TILESEQ.EQ.
9'
-
0
"
CE
I
L
I
N
G
H
T
.
I
N
V
E
S
T
I
B
U
L
E
FU
L
L
TI
L
E
4
F
U
L
L
T
I
L
E
S
FU
L
L
TI
L
E
PA
R
T
I
A
L
TI
L
E
FULL
TILE
3 FULL TILES EQ.EQ.
9'
-
0
"
CE
I
L
I
N
G
H
T
.
I
N
V
E
S
T
I
B
U
L
E
FU
L
L
TI
L
E
4
F
U
L
L
T
I
L
E
S
FU
L
L
TI
L
E
PA
R
T
I
A
L
TI
L
E
END WALL OF
HALLWAY # 104
BEYOND
END WALL OF
HALLWAY #105
BEYOND
END WALL OF
HALLWAY #102
BEYOND
END WALL OF
HALLWAY #114
BEYOND
END WALL OF
HALLWAY #104
BEYOND
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
WOOD FRAMED GLASS
MIRROR (HORIZ.)
BEYOND- CENTERED ON WALL.
C13
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
3'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
1'-6"1'-6"
4 FULL TILES
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
6'
-
4
"
VE
R
I
F
Y
2'
-
8
"
VE
R
I
F
Y
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
TYP.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
SPA LOFT WALL UP
TO DECK.
P1
B1
P7
TYP.
HVAC DUCTWORK
HUNG FROM B.O.
STRUCT. SEE MECH.
PLANS FOR FINISH &
HANGING METHODS.
TYP.A6.3
4
M25InterlockingRock BLOCK BEYOND.
PAINT (FLAT).
RECESSED EMER. LIGHT
FIXTURE IN WALL. PAINT
COVER TO MATCH WALL.
6"
MILLWORK DISPLAY WALL W/ LED/LCD
DISPLAY, ALL INSTALLED BY G.C.
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
T1
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
TYP.A6.3
4
HVAC DUCTWORK HUNG
FROM B.O. STRUCT. SEE
MECH. PLANS FOR FINISH
& HANGING METHODS.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
TYP.A6.3
4
TILE EDGE RETURNS
(1) FULL TILE WIDTH.
HVAC DUCTWORK
HUNG FROM B.O.
STRUCT. SEE MECH.
PLANS FOR FINISH &
HANGING METHODS.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
TYP.A6.3
4
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
T1
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
SPA LOFT WALL
UP TO DECK.
6"
HVAC DUCTWORK
HUNG FROM B.O.
STRUCT. SEE MECH.
PLANS FOR FINISH &
HANGING METHODS.
RECESSED EMER. LIGHT
FIXTURE IN WALL. PAINT
COVER TO MATCH WALL.TYP.
A6.3
4
A6.4
3
A6.4
3
SIM.
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P1
B1
P7
TYP.
DOOR TRACK OVERHANGS
TILE. DO NOT ATTACH
THROUGH TILE.
P3
END OF InterlockingRock
BLOCK WALL. (FLAT).P3 P3
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
INTERIOR ELEVATIONS
A4.0
1
A4.0 1/4"=1'-0"
TYPICAL STOREFRONT ELEVATION 2
A4.0 1/4"=1'-0"
TYPICAL LOFT WALL ELEVATION 3
A4.0 1/4"=1'-0"
VESTIBULE '101' - SOUTH ELEV.4
A4.0 1/4"=1'-0"
VESTIBULE '101' - NORTH ELEV.5
A4.0
NOT USED
6
A4.0 1/4"=1'-0"
HALLWAY '102' - EAST ELEVATION 7
A4.0 1/4"=1'-0"
HALLWAY '104' - NORTH ELEVATION 8
A4.0 1/4"=1'-0"
HALLWAY '105' - EAST ELEVATION
9
A4.0 1/4"=1'-0"
HALLWAY '102' - WEST ELEVATION 10
A4.0 1/4"=1'-0"
HALLWAY '104' - SOUTH ELEVATION 11
A4.0 1/4"=1'-0"
HALLWAY '105' - WEST ELEVATION
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
6"
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
C5
WOOD FRAMED GLASS
MIRROR (HORIZ.)-
CENTER BETWEEN DOORS.
2'
-
6
"
RECESSED FIRE
EXTINGUISHER CABINET-
CENTERED ON WALL.
3'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
P1
P7
B1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
P1
P2
P1
P2
END WALL OF
HALLWAY # 105
BEYOND
END WALL OF
HALLWAY #112
BEYOND
END WALL OF
HALLWAY #106
BEYOND
END WALL OF
HALLWAY #114
BEYOND
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
M3
UTILITY ROOM
WALL UP TO
DECK.
A6.3
4
TYP.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
3'
-
6
"
BO
T
T
O
M
O
F
FR
A
M
E
ACCESSIBLE
TOILET ROOM
SIGNAGE (SEE A0.3).
6"
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
A6.3
4
TYP.
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
A6.3
4
TYP.P2
P1
VACANT LEASE SPACE
WALL UP TO DECK.
LINE OF UTILITY ROOM
WALL UP TO DECK.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
EXPOSED DUCTS &
DIFFUSERS. DO NOT PAINT.
SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
VACANT LEASE
SPACE WALL UP
TO DECK.
P1
B1
P7
TYP.
P1
B1
P7
TYP.
A6.3
4
TYP.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
EXPOSED DUCTS &
DIFFUSERS. DO NOT PAINT.
SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
PAY STATION,
SEE 7/A6.2.
MILLWORK DISPLAY WALL
BEYOND.
P3
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
6"
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
C5
WOOD FRAMED GLASS
MIRROR (HORIZ.)-
CENTER BETWEEN DOORS.
2'
-
6
"
RECESSED FIRE
EXTINGUISHER CABINET-
CENTERED ON WALL.
3'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
P1
P7
B1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
P1
P2
P1
P2
END WALL OF
HALLWAY # 105
BEYOND
END WALL OF
HALLWAY #112
BEYOND
END WALL OF
HALLWAY #106
BEYOND
END WALL OF
HALLWAY #114
BEYOND
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
M3
UTILITY ROOM
WALL UP TO
DECK.
A6.3
4
TYP.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
3'
-
6
"
BO
T
T
O
M
O
F
FR
A
M
E
ACCESSIBLE
TOILET ROOM
SIGNAGE (SEE A0.3).
6"
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
A6.3
4
TYP.
EXPOSED DUCTS & DIFFUSERS.
DO NOT PAINT. SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
A6.3
4
TYP.P2
P1
VACANT LEASE SPACE
WALL UP TO DECK.
LINE OF UTILITY ROOM
WALL UP TO DECK.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
EXPOSED DUCTS &
DIFFUSERS. DO NOT PAINT.
SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
VACANT LEASE
SPACE WALL UP
TO DECK.
P1
B1
P7
TYP.
P1
B1
P7
TYP.
A6.3
4
TYP.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
EXPOSED DUCTS &
DIFFUSERS. DO NOT PAINT.
SEE MECH. PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
PAY STATION,
SEE 7/A6.2.
MILLWORK DISPLAY WALL
BEYOND.
P3
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
INTERIOR ELEVATIONS
A4.1
1
A4.1 1/4"=1'-0"
HALLWAY '106' - NORTH ELEVATION 2
A4.1 1/4"=1'-0"
HALLWAY '106' - SOUTH ELEVATION
3
A4.1 1/4"=1'-0"
HALLWAY '112' - EAST ELEVATION 4
A4.1 1/4"=1'-0"
HALLWAY '112' - WEST ELEVATION
A COMMUNITY OFINDIVIDUAL SALON OWNERS
RECESSED EMER. LIGHT
FIXTURE IN WALL. PAINT
COVER TO MATCH WALL.
6"
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
6"
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
6"
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P2BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P2
BEYOND
P2BEYOND
3'
-
6
"
BO
T
T
O
M
OF
F
R
A
M
E
C5
WOOD FRAMED GLASS
MIRROR (HORIZ.)
CENTER BETWEEN DOORS.
3'
-
6
"
BO
T
T
O
M
OF
F
R
A
M
E
C5
WOOD FRAMED GLASS
MIRROR (HORIZ.)-
CENTER ON WALL.
END WALL OF
HALLWAY #113
BEYOND
END WALL OF
HALLWAY #114
BEYOND
END WALL OF
HALLWAY #114
BEYOND
END WALL OF
HALLWAY #112
BEYOND
END WALL OF
HALLWAY #102
BEYOND
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
SEE ELEVATION 7/A4.2 FOR MORE INFORMATION
MILLWORK DISPLAY WALL
W/ LED/LCD DISPLAY, ALL
INSTALLED BY G.C.
PAY STATION
CABINET, SEE 7/A6.2.
P1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
2'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
B1
P7EQ.EQ.
14'-5"L
(VFY.)
5'
-
6
"
7'
-
3
1
/
2
"
HIDE LED FLEX
POWER SUPPLY
BEYOND EDGE
OF GRAPHIC
PANEL, TYP.
LIGHT AS SCHED.
LIGHT AS SCHED.
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.P2
13'-4"
5 FULL PANELS
P3
M24InterlockingRock PANELS OVER GYP. BD.
WALL SURFACE. INSTALL PER MFR'S. INSTRUCTIONS.
ALL JOINTS TO BE GLUED WITH SEAMS & EDGES
FILLED W/ FORTIFIED SPACKLING COMPOUND &
SANDED SMOOTH, PAINT (FLAT).
3'
-
0
"
P7
6'
-
6
"
CUT
PANEL
B1
CUT DOWN AS REQ'D.
3"
8'
-
0
"
InterlockingRock BLOCK INSTALL PER MANUF.
INSTRUCTIONS USING STANDARD 1 5/8"x 1 1/4" MTL.
STUDS AND TRACK. ALL JOINTS GLUED, SEAMS AND EDGES
FILLED WITH FORTIFIED SPACKLING COMPOUND &
SANDED SMOOTH. PAINT (FLAT).P3
6'-0"
NOTE: CONTRACTOR SHALL
COORD. STEEL REQ'D. TO
STIFFEN END OF WALL WITH
SALON LOFTS REP. ON SITE.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
LIGHT AS SCHED.LIGHT AS SCHED.
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.P2
M25
A6.3
4
TYP.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P1
B1
P7
TYP.
P3
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
A6.3
4
TYP.
EXPOSED DUCTS &
DIFFUSERS.
DO NOT PAINT.
SEE MECH. PLANS.
P3
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.EXPOSED DUCTS &
DIFFUSERS. DO NOT
PAINT. SEE MECH. PLANS.
TYP.A6.3
4
ILLUMINATED SALON LOFTS PUCK
& GRAPHIC PANEL, SUPPLIED BY
SALON LOFTS / INSTALLED BY G.C.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P3
TYP.A6.3
4
A6.4
3
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P3
EXPOSED
DUCTS &
DIFFUSERS. DO
NOT PAINT.
SEE MECH.
PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
EXPOSED DUCTS &
DIFFUSERS. DO NOT
PAINT. SEE MECH. PLANS.
P3
PAY STATION-
SEE 7/A6.2.
A COMMUNITY OFINDIVIDUAL SALON OWNERS
RECESSED EMER. LIGHT
FIXTURE IN WALL. PAINT
COVER TO MATCH WALL.
6"
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
6"
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
TYP. LOFT SIGNAGE
BEYOND, SEE 7/A6.1.
RECESSED EMER.
LIGHT FIXTURE IN
WALL. PAINT COVER
TO MATCH WALL.
6"
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
P2
BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
LOFT DOOR IN
'OPEN' POSITION
SHOWN DASHED.
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P2BEYOND
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
P2
BEYOND
P2BEYOND
3'
-
6
"
BO
T
T
O
M
OF
F
R
A
M
E
C5
WOOD FRAMED GLASS
MIRROR (HORIZ.)
CENTER BETWEEN DOORS.
3'
-
6
"
BO
T
T
O
M
OF
F
R
A
M
E
C5
WOOD FRAMED GLASS
MIRROR (HORIZ.)-
CENTER ON WALL.
END WALL OF
HALLWAY #113
BEYOND
END WALL OF
HALLWAY #114
BEYOND
END WALL OF
HALLWAY #114
BEYOND
END WALL OF
HALLWAY #112
BEYOND
END WALL OF
HALLWAY #102
BEYOND
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL/HEADER
CONDITION TO BE PAINTED
, SEE DETAIL 5/A6.1.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
SEE ELEVATION 7/A4.2 FOR MORE INFORMATION
MILLWORK DISPLAY WALL
W/ LED/LCD DISPLAY, ALL
INSTALLED BY G.C.
PAY STATION
CABINET, SEE 7/A6.2.
P1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
P1
P7
B1
TYP.
TYP.
2'
-
6
"
2'
-
6
"
2'
-
6
"
2'
-
6
"
B1
P7EQ.EQ.
14'-5"L
(VFY.)
5'
-
6
"
7'
-
3
1
/
2
"
HIDE LED FLEX
POWER SUPPLY
BEYOND EDGE
OF GRAPHIC
PANEL, TYP.
LIGHT AS SCHED.
LIGHT AS SCHED.
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.P2
13'-4"
5 FULL PANELS
P3
M24InterlockingRock PANELS OVER GYP. BD.
WALL SURFACE. INSTALL PER MFR'S. INSTRUCTIONS.
ALL JOINTS TO BE GLUED WITH SEAMS & EDGES
FILLED W/ FORTIFIED SPACKLING COMPOUND &
SANDED SMOOTH, PAINT (FLAT).
3'
-
0
"
P7
6'
-
6
"
CUT
PANEL
B1
CUT DOWN AS REQ'D.
3"
8'
-
0
"
InterlockingRock BLOCK INSTALL PER MANUF.
INSTRUCTIONS USING STANDARD 1 5/8"x 1 1/4" MTL.
STUDS AND TRACK. ALL JOINTS GLUED, SEAMS AND EDGES
FILLED WITH FORTIFIED SPACKLING COMPOUND &
SANDED SMOOTH. PAINT (FLAT).P3
6'-0"
NOTE: CONTRACTOR SHALL
COORD. STEEL REQ'D. TO
STIFFEN END OF WALL WITH
SALON LOFTS REP. ON SITE.
P2
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.
LIGHT AS SCHED.LIGHT AS SCHED.
THREADED ROD & UNI-STRUT
SUPPORTS FOR FLOATING GYP.
BD. CEILING TO BE PAINTED
, SEE DETAIL 5/A6.4.P2
M25
A6.3
4
TYP.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P1
B1
P7
TYP.
P3
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
A6.3
4
TYP.
EXPOSED DUCTS &
DIFFUSERS.
DO NOT PAINT.
SEE MECH. PLANS.
P3
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.EXPOSED DUCTS &
DIFFUSERS. DO NOT
PAINT. SEE MECH. PLANS.
TYP.A6.3
4
ILLUMINATED SALON LOFTS PUCK
& GRAPHIC PANEL, SUPPLIED BY
SALON LOFTS / INSTALLED BY G.C.
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P3
TYP.A6.3
4
A6.4
3
FINISH FLOOR
+0'-0" A.F.F.
FIELD VERIFY
B.O. ROOF DECK
P3
EXPOSED
DUCTS &
DIFFUSERS. DO
NOT PAINT.
SEE MECH.
PLANS.
HVAC DUCTWORK HUNG FROM
B.O. STRUCT. SEE MECH. PLANS
FOR FINISH & HANGING METHODS.
EXPOSED DUCTS &
DIFFUSERS. DO NOT
PAINT. SEE MECH. PLANS.
P3
PAY STATION-
SEE 7/A6.2.
A6.1
4
A6.1
3
A6.1
4SEE DETAIL 3/A4.0 FOR
FINISH SELECTIONS
T1
(1) 4'-0" L. LED LINEAR WALL
WASH FIXTURE SUPPLIED BY
SALON LOFTS & INSTALLED
BY G.C. IN RECESSED LIGHT
COVE. COORD. LIGHTING
TYPE & DETAILS W/ ELEC. &
3/A6.1.
TYP.
EA.
SIDE ACRYLIC PANEL (BY G.C.)
W/ SALON LOFTS GRAPHIC
PROVIDE KEYED
CABINET LOCK.
NAIL POLISH CABINET W/
1/8" CLEAR TEMP. GLASS
DOOR PANELS IN P.LAM.
FRAME .
EXHAUST GRILLE IN
WALL- PAINT TO MATCH
WALL & SEE MECH.
PLANS.
DISPLAY CABINET OUTER
FRAME TO BE 5" DEEP.
PROVIDE (9) 4" DEEP
FIXED SHELVES SPACED
4" CLEAR TYPICAL AS
DIMENSIONED.
PL-2
B1
P1
1'-6"4'-3"
4"
TY
P
.
EQ.EQ.
2'
-
0
"
9
1
/
2
"
4'
-
2
1
/
2
"
7'
-
0
"
9'
-
6
"
TY
P
.
W
A
L
L
H
E
I
G
H
T
A6.2
5
PL-2
PL-2
PL-2
PL-2
P.LAM PORTABLE
CABINET ON
CASTERS ,
SEE DETAIL 6/A6.2.
PROVIDE KEYED
CABINET LOCK TYP.
EACH DOOR.
LOWER CABINET DOORS
W/ FINISH.
PROVIDE (3)
ADJUSTABLE SHELVES
EACH SECTION.
(PROVIDE DOOR STOPS
@ UPPER CORNER NEAR
FINGER PULL OPENING).
UPPER CABINET DOORS
W/ PERIMETER
FRAME W/ 1/8" FROSTED
ACRYLIC PANEL. PROVIDE
(1) ADJUSTABLE SHELF
EACH SECTION.
WALL MOUNTED P.LAM
CABINETS W/ TYP.
ALL EXPOSED SURFACES.
NAIL SINK-
SEE 6/A2.2.
B1
P1
1'-6"
1'
-
6
3
/
4
"
3/
4
"
3'
-
4
"
1'
-
8
"
7'
-
0
"
1'-6"1'-6"1'-0"
4'-6"
5"
5"5"
4'-8"
COORD. W/ FLOOR PLAN
3'-10"5"5"
4'-8"
COORD. W/ FLOOR PLAN
3'-10"
2'
-
8
"
4'
-
7
"
5"
1'
-
1
1
"
6"2"
4"
FINISH ALL EXPOSED
SURFACES OF PAY
STATION CASEWORK
, U.N.O.
P.LAM DRAWER
FRONT .
P.LAM DOOR
FRONT .
PL-4
PL-4
PL-4
P.LAM WORK
SURFACE TOP AS
DETAILED .PL-1
PL-4
PULL-OUT CHECK
WRITING LEDGE
.PL-1
8'
-
0
"
LED/LCD
DISPLAY-
MOUNT TOP OF
DISPLAY AS
INDICATED.
PL-4
B1
4'
-
8
"
4"
1'
-
6
"
1'
-
1
"
8'
-
0
"
5"
6'
-
0
"
1'
-
6
"
B1
INTERIOR ELEVATIONS
A4.2
2
A4.2 1/4"=1'-0"
HALLWAY '114' - NORTH ELEVATION1
A4.2 1/4"=1'-0"
HALLWAY '113' - EAST ELEVATION
4
A4.2 1/4"=1'-0"
HALLWAY '114' - SOUTH ELEVATION3
A4.2 1/4"=1'-0"
HALLWAY '113' - WEST ELEVATION
5
A4.2 1/2"=1'-0"
NAIL ' 02' - WEST ELEVATION
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
6
A4.2 1/2"=1'-0"
NAIL ' 02' - EAST ELEVATION 7
A4.2 1/2"=1'-0"
ENLARGED WAY FINDING ELEV.8
A4.2 1/2"=1'-0"
ENLARGED WAY FINDING ELEV.9
A4.2 1/2"=1'-0"
ENLARGED GRAPHIC WALL DISPLAY
A6.0
3
LOFT DOOR AS
SCHED. IN "OPEN"
POSITION.
WALL FINISH
TRANSITION AS
SCHEDULED.
6"6"
FINISHES RETURN/
WRAP JAMB, TYP.
NOTE: SEE PLAN FOR TRUE CONFIGURATION.
10'-0" LONG
HARDWOOD SILL
GUIDE TRACK,
SCREWED INTO
CONC. SLAB, TYP.
BEARING ASSEMBLY &
HEAVY DUTY BRACKET.
HEAVY DUTY TRACK,
SEE DETAIL 1A/A6.4
LOFT DOOR AS SCHED. IN
"CLOSED" POSITION.
DOOR HANDLE.
1/2" CLEAR TEMPERED
GLAZING.
DOOR LOCKING
CYLINDER AS SCHED.
WALL BASE AS SCHED.
LINE OF FINISHED
FLOOR.
RECESSED BOTTOM GUIDE AS
SCHED. COORD. DEPTH OF
RECESS W/ DOOR HARDWARE.
DIMENSION INDICATES DOOR
OVERLAP OF FINISHED GYP. OPENING.
A6.0
6
A6.0
9
WALL BASE AS
SCHED.
GLAZING BASE.
FIN. DOOR HEAD
EL. = 7'-10"
TOP OF FLOOR
EL. = 0'-0"
6'-4"
FINISHED OPENING
2"3'-7"2'-6"3"3'-6"
DOOR IN
"OPEN"
POSITION
10'-0"
(TRACK LENGTH)
WALL FINISH AS SCHED.
LOFT SIGNAGE,
SEE DETAIL 7/A6.1.
ADJACENT DOOR OPENING
SHOWN DASHED.
A6.0
3
LOFT DOOR AS
SCHED. IN "OPEN"
POSITION.
WALL FINISH
TRANSITION AS
SCHEDULED.
6"6"
FINISHES RETURN/
WRAP JAMB, TYP.
NOTE: SEE PLAN FOR TRUE CONFIGURATION.
8'-6" LONG
HARDWOOD SILL
GUIDE TRACK,
SCREWED INTO
CONC. SLAB, TYP.
BEARING ASSEMBLY &
HEAVY DUTY BRACKET.
HEAVY DUTY TRACK,
SEE DETAIL 1B/A6.4
ADJACENT DOOR OPENING
SHOWN DASHED.
WALL FINISH AS SCHED.
LOFT SIGNAGE,
SEE DETAIL 7/A6.1.
LOFT DOOR AS SCHED. IN
"CLOSED" POSITION.
DOOR HANDLE.
1/2" CLEAR TEMPERED
GLAZING.
DOOR LOCKING
CYLINDER AS SCHED.
WALL BASE AS SCHED.
LINE OF FINISHED
FLOOR.
RECESSED BOTTOM GUIDE AS
SCHED. COORD. DEPTH OF
RECESS W/ DOOR HARDWARE.
DIMENSION INDICATES DOOR
OVERLAP OF FINISHED GYP. OPENING.
A6.0
6
A6.0
9
WALL BASE AS
SCHED.
GLAZING BASE.
TOP OF FLOOR
EL. = 0'-0"
6'-4"
FINISHED OPENING
2"3'-7"2'-6"3"2'-0"
DOOR IN
"OPEN"
POSITION
8'-6"
(TRACK LENGTH)
FIN. DOOR HEAD
EL. = 7'-10"
TOP OF WALL
EL. = 9'-6"
TOP OF WALL
EL. = 9'-6"
A6.0
3LOFT DOOR AS SCHED. IN
"OPEN" POSITION.
WALL FINISH TRANSITION
AS SCHEDULED.
FINISHES RETURN/ WRAP
JAMB, TYP.
NOTE: SEE PLAN FOR TRUE CONFIGURATION.
6'-3" LONG HARDWOOD SILL
GUIDE TRACK, SCREWED
INTO CONC. SLAB, TYPICAL.
BEARING ASSEMBLY &
HEAVY DUTY BRACKET.
HEAVY DUTY TRACK,
SEE DETAIL 1D/A6.4
WALL FINISH AS SCHED.
LOFT DOOR AS SCHED. IN
"CLOSED" POSITION.
DOOR HANDLE.
1/2" CLEAR TEMPERED
GLAZING.
DOOR LOCKING
CYLINDER AS SCHED.
WALL BASE AS SCHED.
LINE OF FINISHED FLOOR.
RECESSED BOTTOM GUIDE
AS SCHED. COORD. DEPTH
OF RECESS W/ DOOR
HARDWARE.DIMENSION INDICATES DOOR OVERLAP
OF FINISHED GYP. OPENING.
A6.0
6
A6.0
9 GLAZING BASE.
TOP OF FLOOR
EL. = 0'-0"
5'-0"3'-2"
DOOR IN OPEN POSITION
2'-10"3"
6'-0"
(TRACK LENGTH)
FIN. DOOR HEAD
EL. = 7'-10"
TOP OF WALL
EL. = 9'-6"
6"6"
2"
LOFT SIGNAGE , SEE 7/A6.1.
(APPLY W/ CLEAR DLB.
SIDED TAPE TO F.O. GLASS.).
7"
TYP.
U.N.O.
4 7/8"7"
TYP.
U.N.O.
6'-4"
3'-7"2'-6"3"
3'-6"3"
2"
"HALLWAY" SIDE
"LOFT" SIDE
EQ
.
2"
EQ
.
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
WALL
PARTITION AS
SCHEDULED.
DOOR BOTTOM GUIDE-
SET IN 6" FROM DOOR END.
A6.0
1
4"
7/
8
"
NOTE: SEE PLAN FOR
TRUE CONFIGURATION.
ADJACENT DOOR
OPENING & DOOR
AS SCHED. SEE
FLOOR PLAN.
LOFT SIGNAGE
LOCATION SHOWN
DASHED ABOVE. SEE
DETAIL 7/A6.1.
METAL STUD FRAMING AS REQ'D.
FOR HEADER SUPPORT. TYP. BOTH
SIDES.
WALL PARTITION AS SCHEDULED.
3'-6"
DOOR IN
"OPEN" POSITION
DOOR SHOWN IN "OPEN" POSITION
(DASHED).
GLAZING BASE.
1/2" CLEAR TEMP. GLAZING.
LINE OF FLOOR FINISH TRANSITION
AS DIMENSIONED OFF FINISHED
FACE OF WALL PARTITION AS
SHOWN.
F1
F2
7"
TYP.
U.N.O.
4 7/8"7"
TYP.
U.N.O.
6'-4"
3'-7"2'-6"3"
3'-6"3"
2"
"HALLWAY" SIDE
"LOFT" SIDE
EQ
.
2"
EQ
.
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
WALL
PARTITION AS
SCHEDULED.
DOOR BOTTOM GUIDE-
SET IN 6" FROM DOOR END.
A6.0
4
4"
7/
8
"
NOTE: SEE PLAN FOR
TRUE CONFIGURATION.
ADJACENT DOOR
OPENING & DOOR
AS SCHED. SEE
FLOOR PLAN.
LOFT SIGNAGE
LOCATION SHOWN
DASHED ABOVE. SEE
DETAIL 7/A6.1.
METAL STUD FRAMING AS REQ'D.
FOR HEADER SUPPORT. TYP. BOTH
SIDES.
WALL PARTITION AS SCHEDULED.
2'-0"
DOOR IN
"OPEN" POSITION
DOOR SHOWN IN "OPEN" POSITION
(DASHED).
GLAZING BASE.
1/2" CLEAR TEMP. GLAZING.
LINE OF FLOOR FINISH TRANSITION
AS DIMENSIONED OFF FINISHED
FACE OF WALL PARTITION AS
SHOWN.
F1
F2
2'-10"2"
"HALLWAY" SIDE
"LOFT" SIDE
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
DOOR BOTTOM GUIDE-
SET IN 6" FROM DOOR
EDGE.
A6.0
7
DOOR SHOWN IN "OPEN"
POSITION (DASHED).
GLAZING BASE.
1/2" CLEAR TEMP.
GLAZING.
LINE OF FLOOR FINISH TRANSITION
AS DIMENSIONED OFF FINISHED FACE
OF WALL PARTITION AS SHOWN.
3"
3'-1"
7/
8
"
1'-11"
METAL STUD FRAMING AS
REQ'D. FOR HEADER
SUPPORT. TYP. BOTH SIDES.
WALL PARTITION
AS SCHEDULED.
3'-0"
DOOR IN
"OPEN" POSITION
F2
F1
4"
EQ
.
2"
EQ
.
5'-0"
3'
-
6
"
3"
1/2" CLEAR TEMPERED
GLAZING W/ POLISHED
EDGES, TYP.
EQ.EQ.
STYLMARK GLAZING BASE
#110482 2"x4" (FINISH
#218-BRUSHED BRITE
STAINLESS STEEL). NOTE:
PROVIDE STYLMARK 1/8"
ENDCAP #410367 TYP. @
EXPOSED ENDS WITH
MATCHING FINISH.
WALL BASE BEYOND AS
SCHED.
STYLMARK ANCHOR #110358
W/ TOGGLE TO FINISHED
FLOOR. ANCHOR INTO CONC.
SLAB.
4"
CHANNEL
LINE OF WALL PARTITION
JAMB BEYOND.
FLOOR FINISH AS SCHED.F1
WALL BASE BEYOND AS
SCHED.
SET GLAZING W/ BLACK
GLAZING VINYL #226024 &
#226025, AND SETTING
BLOCKS #226014.
BOTTOM GUIDE AS SCHEDULED
RECESSED INTO DOOR BOTTOM.
VERIFY RECESSED DEPTH W/
DOOR HARDWARE.
7/8"
1/
2
"
5/
8
"
HARDWOOD SILL GUIDE TRACK
SCREWED INTO FLOOR SLAB
THROUGH RECESSED SLOT.
LOFT DOOR AS SCHED. IN
"OPEN" POSITION.
CARPET FLOOR FINISH AS
SCHED.F2
TOP OF WALL
EL. = 9'-6" ABOVE
FINISHED FLOOR SURFACE
FINISHED DOOR HEAD
EL. = 7'-10" ABOVE
FINISHED FLOOR SURFACE
EQ.EQ.CHANNEL
WALL PARTITION AS SCHED.
STYLMARK GLAZING HEAD
#110360 1"x2". (FINISH #218-
BRUSHED BRITE STAINLESS
STEEL) NOTE: PROVIDE
STYLMARK 1/8" ENDCAP
#410412 TYP. @ EXPOSED ENDS
WITH MATCHING FINISH.
1/2" CLEAR TEMPERED
GLAZING.
FINISHED FLOOR SURFACE
WALL PARTITION AS SCHED.
METAL STUD BOX BEAM -
3 5/8" (18 GA.) STUDS, 1 5/8" FLANGE, W/
3 5/8" (20 GA.) RUNNER TOP & BOTTOM.
LINE OF WALL PARTITION
JAMB BEYOND.
HEAVY DUTY DOOR TRACK.
RETURN GYP. BD. TO
GLAZING HEAD AS SHOWN.
SET GLAZING W/ BLACK
GLAZING VINYL #226013.
TOP OF WALL
EL. = 9'-6" ABOVE
LINE OF WALL PARTITION JAMB
BEYOND.
FINISHED GYP. BD. HEAD AS
SHOWN.
A6.3
4
TYP.
(2) 2x4 F.R.T. WOOD BLOCKING.
(2) 2x4 F.R.T. WOOD BLOCKING.
A6.3
4
TYP.
BEARING ASSEMBLY AS
SUPPLIED BY MFR.
HEAVY DUTY TRACK W/ 2-5/8"
SPACERS & MOUNTING SCREWS
INTO SOLID WD. BLOCKING BY G.C.
HEAVY DUTY BRACKET W/
MOUNTING BOLTS AS SUPPLIED
BY MFR.
1 3/4" THICK DOOR PANEL
AS SCHED.1 3/4"
DOOR
FINISHED DOOR HEAD
EL. = 7'-10" A.F.F.
2
1
/
4
"
T.
O
.
D
O
O
R
TO
OF
T
R
A
C
K
3
1
/
8
"
METAL STUD BOX BEAM -
3 5/8" (18 GA.) STUDS, 1 5/8"
FLANGE, W/ 3 5/8" (20 GA.)
RUNNER TOP & BOTTOM.
CERAMIC TILE FLOOR FINISH
AS SCHED.F1
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
DOOR & SIDELIGHT
ELEVATIONS & DETAILS
A6.0
1
A6.0 1/2"=1'-0" 10'-0" LONG DOOR TRACK
TYPICAL LOFT DOOR ELEVATION
4
A6.0 1/2"=1'-0" 8'-6" LONG DOOR TRACK
TYPICAL LOFT DOOR ELEVATION
2
A6.0 3/4"=1'-0" 10'-0" LONG DOOR TRACK
TYPICAL LOFT DOOR JAMB DETAIL
5
A6.0 3/4"=1'-0" 8'-6" LONG DOOR TRACK
TYPICAL LOFT DOOR JAMB DETAIL
3
A6.0 3"=1'-0"
LOFT OPENING GLAZING DETAIL
6
A6.0 3"=1'-0"
LOFT OPENING DOOR HEAD DETAIL
9
A6.0 3"=1'-0"
LOFT OPENING GLAZING DETAIL7
A6.0 1/2"=1'-0" 6'-0" LONG DOOR TRACK
TYPICAL LOFT DOOR ELEVATION 8
A6.0 3/4"=1'-0" 6'-0" LONG DOOR TRACK
TYPICAL LOFT DOOR JAMB DETAIL
LOFT DOOR AS
SCHED. IN "OPEN"
POSITION.
WALL BASE
AS SCHED.
WALL FINISH
TRANSITION.
DIM. INDICATES
DOOR OVERLAP
OF FINISHED GYP.
BD. OPENING.
WALL FINISH
AS SCHED.
RECESSED BOTTOM GUIDE AS
SCHED. COORD. DEPTH OF
RECESS W/ DOOR HARDWARE.
7'-1" LONG HARDWOOD SILL
GUIDE TRACK, SCREWED INTO
FLOOR, TYP.
LOFT SIGNAGE , SEE
7/A6.1. (APPLY W/ CLEAR
DLB. SIDED TAPE TO F.O.
GLASS.).
LOFT DOOR AS SCHED. IN
"CLOSED" POSITION.
DOOR HANDLE.
1/2" CLEAR TEMPERED
GLAZING.
DOOR LOCKING CYLINDER
AS SCHEDULED.
LINE OF FINISHED
FLOOR.
GLAZING BASE.
EL. = 7'-10"
FINISHED DOOR HEAD
EL. = 0'-0"
TOP OF FLOOR
7'
-
1
0
"
(F
U
T
U
R
E
G
Y
P
.
B
D
.
O
P
E
N
I
N
G
)
6'-0"
(FUTURE GYP. BD. OPENING)
9'
-
6
"
LINE OF FUTURE GYP.
BD. OPENING SHOWN
W/ HEAVY DASH. GYP.
BD. PANEL JOINTS TO
BE LOCATED @ EDGE
OF FUTURE GYP. BD.
OPENING FOR EASE OF
OPENING REMOVAL &
CONSTR.
G.C. TO PROVIDE F.R.T.
BLKG. WITHIN FRAMED
WALL CONSTRUCTION
AS REQ'D. FOR FUTURE
MILLWORK ITEMS.
COORD. MILLWORK
SPECIFICATIONS &
LOCATIONS W/ OWNER
PRIOR TO CONSTR.
1'
-
8
"
(W
A
L
L
T
O
RE
M
A
I
N
)
EQUAL
(WALL TO
REMAIN)
EQUAL
(WALL TO
REMAIN)
PERMANENT FRAMING
AS REQ'D. SHOWN
DASHED.
TEMPORARY FRAMING
AS REQ'D. WITHIN
FUTURE GYP. BD.
OPENING AREA. AREA
TO BE FRAMED SUCH
THAT TEMPORARY
FRAMING TO BE
REMOVED WITHOUT
DISRUPTING
PERMANENT FRAMING
SURROUNDING GYP.
BD. OPENING.
ELEC. AS NOTED, SEE
ELEC. DRAWINGS. ALL
ELEC., DATA,
TELEPHONE, & LOW
VOLTAGE ITEMS TO BE
LOCATED WITHIN AREA
OF PERMANENT FRMG.
NO WIRES OR ITEMS
TO BE LOCATED
WITHIN AREA OF
TEMP. FRAMING AT
FUTURE GYP. BD.
OPENING.
WALL BASE AS
SCHEDULED, SEE
INTERIOR ELEVATIONS.
BEARING ASSEMBLY &
HEAVY DUTY BRACKET.
HEAVY DUTY TRACK,
SEE DETAIL 1C/A6.4.
6'-10"
(TRACK LENGTH)
6"6"
3"3'-4"2"
3'-7"
FINISHED OPENING
3'-6"
DOOR IN "OPEN" POSITION
B1
A6.0
3
A6.0
9
A6.0
6AT SIM. DOOR, NO GLASS
CORNER. SEE SHEET A2.0
FOR OPENING DIMENSIONS.
3'-4"
2""HALLWAY" SIDE
"LOFT" SIDE
EQ
.
2"
EQ
.
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
DOOR BOTTOM GUIDE-
SET IN 6" FROM DOOR
EDGE.
A6.1
9
DOOR SHOWN IN
"OPEN" POSITION (DASHED).
GLAZING BASE.
1/2" CLEAR TEMP.
GLAZING.
LINE OF FLOOR FINISH TRANSITION
AS DIMENSIONED OFF FINISHED FACE
OF WALL PARTITION AS SHOWN.
3"
3'-7"
7/
8
"
2'-3"
METAL STUD FRAMING AS
REQ'D. FOR HEADER
SUPPORT. TYP. BOTH SIDES.
WALL PARTITION
AS SCHEDULED.
3'-6"
DOOR IN
"OPEN" POSITION
F2
F1
4"
AT SIM. DOOR, NO GLASS
CORNER. SEE SHEET A2.0
FOR OPENING DIMENSIONS.
5'-7"
THREADED ROD & UNI-STRUT
SUPPORTS FOR WALL / CEILING /
FLOATING CEILING SUPPORT TO BE
PAINTED . DESIGN BY OTHERS.
G.C. TO PROVIDE UNI-STRUT SUPPORT
AS REQUIRED WITHIN WALL
CONSTRUCTION (SHOWN DASHED).
FASTEN UNI-STRUT TO WALL FRAMING.
EXISTING TRUSSES TO REMAIN.
UNI-STRUT SUPPORT TO
BE HUNG FROM LOWER CHORD,
COORDINATE W/ LANDLORD.
DECK ABOVE.
TOP OF WALL CONSTRUCTION,
SEE FLOOR PLAN FOR NOTES.
P2
WALL SYSTEM AS SCHEDULED.
3'-0" / 3'-6"
VERIFY WITH SHEET A2.0LINE OF FLOOR FINISH BELOW,
SEE FINISH PLAN FOR DETAILS.
GLAZING BASE AS NOTED,
SEE DETAIL 9/A6.0.
PROVIDE 1/2" CLEAR
TEMPERED GLAZING W/
POLISHED EDGES, TYP.
BUTT LAP CORNER AS
INDICATED - NO SILICONE.
LINE OF SOFFIT CONSTRUCTION
ABOVE SHOWN DASHED - SEE
5/A6.1 FOR SUPPORT DETAILS.
EQ
EQ
3"
"HALLWAY" SIDE
"SPA LOFT" /
"SPA VESTIBULE" SIDE
DOOR OPENING
AS SCHEDULED
7"
DOOR W/ HOLLOW
METAL FRAME &
SOUND GASKETING
AS SCHED.
'P5' PARTITION CONSTR. ('P6' SIM.)
(CONFORM TO TEST #RAL-TL-07-168 / STC 60):
FACE LAYER OF 5/8" GYP. BD. ON BASE LAYER
OF 5/8" SOUNDBREAK XP GYP. BD. (SHOWN
SHADED) VERT. APPLIED TO "HALLWAY"/
"TYPICAL LOFT" SIDE OF 6" MTL. STUDS AT 24"
O.C. (16" O.C. @ 'P6' PARTITION TYPE) W/
5 1/2" FIBERGLASS SOUND BATT INSUL. (2)
LAYERS 5/8" GYP. BD. VERT. APPLIED TO "SPA
LOFT" SIDE. BASE LAYER TO BE ATTACHED W/
1" TYPE S SCREWS 24" O.C. FACE LAYER
ATTACHED W/ 1 5/8" TYPE S SCREWS 12" O.C.
VERTICAL JOINTS TO BE STAGGERED 24" EA.
LAYER AND OPPOSITE SIDES. WALL TRACK TO
BE SET IN ACOUSTICAL SEALANT & IS TO
EXTEND FROM FINISHED FLOOR TO UNDERSIDE
OF ROOF DECK. ALL SEAMS & GAPS IN WALL
CONSTRUCTION TO BE FILLED W/ ACOUSTICAL
SEALANT, TYPICAL AT EACH SIDE OF WALL.
4"
LOFT SIGNAGE
LOCATION (VERIFY
W/ SHEET A2.3)
AS DIMENSIONED.
SEE DETAIL 7/A6.1.
LINE OF FLOOR FINISH
TRANSITION AS
DIMENSIONED OFF
FINISHED FACE OF WALL
PARTITION AS SHOWN.
NOTE: SEE PLAN FOR TRUE
CONFIGURATION.
P1 P5
SIGN
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
F2
FL
O
O
R
F
I
N
I
S
H
AS
S
C
H
E
D
.
F6
P5
"T
Y
P
I
C
A
L
L
O
F
T
"
S
I
D
E
8
1
/
2
"
ALIGN
NOTE: PENETRATIONS THROUGH
THE P5/P6 PARTITION TYPE TO BE
LIMITED. ALL PENETRATIONS ARE
TO BE SEALED WITH ACOUSTICAL
SEALANT, TYP.
3'-10" A.F.F.
B.O. CARD HOLDER
3'-6" A.F.F.
B.O. CARD HOLDER
TYP. LOFT SIGNAGE W/ LOFT NUMBER
& INTEGRAL CARD HOLDER. SUPPLIED
& INSTALLED BY SALON LOFTS.
TYP. CARD HOLDERS SUPPLIED &
INSTALLED BY SALON LOFTS.
OF LOFT
SIGNAGE
5 1/2"
NOTE: WHEN SIGNS ARE INDICATED
TO BE ON THE GLASS WALLS, APPLY
TO FACE OF GLASS W/ CLEAR
DOUBLE SIDED TAPE. INSTALL W/
TYPICAL 5 1/2" DIMENSION FROM
EDGE OF GLASS.
LINE OF FINISHED DOOR OPENING.
FINISHED DOOR PANEL AS SCHEDULED.
4'-2" A.F.F.
B.O. CARD HOLDER @ SIGN
WALL TILE.
1'-6" F.O. FRAME TO FACE OF GYP. BD.
(1) FULL TILE (CUT AS REQ'D.)
WALL SYSTEM AS
SCHEDULED.
WALL TILE SATIN ALUMINUM (AE)
TILE CORNER TRIM -
SCHLUTER-RONDEC.
SEALANT TO MATCH
GROUT.
SATIN ALUMINUM (AE)
TILE EDGE TRIM -
SCHLUTER-SCHIENE.
(1
)
F
U
L
L
T
I
L
E
WALL TILE
WALL SYSTEM AS
SCHEDULED
SATIN ALUMINUM (AE)
TILE EDGE TRIM -
SCHLUTER-QUADEC
14" CLEAR MIRROR SET
FLUSH WITH TILE
MI
R
R
O
R
T1
T1
T1
T1
A2.0
3
@ HEAD
WALL GRAPHIC BY SALON LOFTS.
RETURNS @JAMB BEYOND
1 1/2" SATIN ALUMINUM (AE) TILE
TRIM - SCHLUTER RONDEC-STEP.
LED LINEAR WALL WASH FIXTURE
WITH ADJUSTABLE CLIP SUPPLIED
BY SALON LOFTS & INSTALLED BY
G.C. COORD. EXACT MOUNTING
LOCATION WITH SALON LOFTS'
REPRESENTATIVE.
WALL TILE.
5/8" GYP. BD. OVER 3-5/8" METAL
STUDS (ALL TO MATCH ADJACENT
WALL HEIGHT).
WALL SYSTEM AS SCHEDULED.
5"
EXTEND TILE JAMB INTO & UP TO
TOP OF LIGHT COVE.
4 5/8"+/-
WALL TILE.
5/8" GYP. BD. OVER 3-5/8" METAL STUDS.
WALL SYSTEM AS SCHEDULED.
WALL TILE SILL. MATCH
GROUT LINES WITH WALL TILE
BELOW.
1'
-
6
"
FU
L
L
T
I
L
E
TO
F
I
N
I
S
H
E
D
FL
O
O
R
4 5/8"+/-
WALL GRAPHIC BY SALON LOFTS.
ADHERED ACRYLIC PANEL OVER
GYP. BD. TO BE ONE CONTIN.
PIECE, TYP. (ALL BY G.C.)9 1/2"±
T1
T1
T1
T1
ACRYLIC PANEL
OVER GYP. BD.
SURFACE TO BE
ONE CONTIN. PIECE,
TYP. INSTALL PRIOR
TO LED LIGHT
FIXTURE. (ALL BY
G.C.)
ACRYLIC PANEL
EXTENDS TO TOP
OF LIGHT COVE.
SATIN ALUMINUM (AE) TILE CORNER
TRIM - SCHLUTER RONDEC.
A6.1
4
SATIN ALUMINUM (AE) TILE CORNER
TRIM BEYOND - SCHLUTER RONDEC.
MATCH GROUT LINES WITH
ADJACENT WALL TILE.
T1
PROVIDE HEMMED EDGE TO BREAK
METAL CAP AT EDGE RETURN AS
SHOWN. (TYP. BOTH SIDES.).
1
1
/
2
"
RE
T
U
R
N
PARTITION WALL AS SCHED.
PROVIDE SEALANT, COLOR TO
MATCH BREAK METAL. (TYP. BOTH
SIDES.).
PROVIDE PREFINISHED ALUMINUM
BREAK METAL CAP @ EXPOSED END
OF WALL PARTITION. COLOR TO
MATCH GLAZING FRAME COLOR.
ALUM. GLASS STOREFRONT
GLAZING SYSTEM.
NOTE: WHERE WALL PARTITION DOES NOT TERMINATE AT VERTICAL
GLAZING MULLION, WALL PARTITION WITH BREAK METAL CAP TO RUN TO
WITHIN 12"-34" OF GLASS FOR TERMINATION POINT.
STUD=
MULLION
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
CONSTRUCTION
DETAILS
A6.1
1
A6.1 3"=1'-0"
TILE / MIRROR TRANSITION DETAIL 2
A6.1 3"=1'-0"
TILE WALL CORNER DETAIL 3
A6.1 3"=1'-0"
LIGHT COVE HEAD DETAIL 4
A6.1 3"=1'-0"
LIGHT COVE SILL DETAIL (JAMB SIM.)
5
A6.1 1"=1'-0"
LOFT SOFFIT DETAIL 7
A6.1 1 1/2"=1'-0"
LOFT SIGNAGE DETAIL6
A6.1 6"=1'-0"
WALL CAP AT GLAZING DETAIL 8
A6.1 1/2"=1'-0"
LOFT WALL FRAMING ELEVATION
9
A6.1 1/2"=1'-0" 6'-10" LONG DOOR TRACK
TYPICAL LOFT DOOR ELEVATION 10
A6.1 3/4"=1'-0" 6'-10" LONG DOOR TRACK
TYPICAL LOFT DOOR JAMB DETAIL 11
A6.1 1 1/2"=1'-0"
LOFT CORNER GLAZING DETAIL 12
A6.1 1 1/2"=1'-0"
SPA LOFT WALL / JAMB DETAIL
3'
-
0
"
2"1/
4
"
5
3
/
4
"
1"
1'
-
9
"
6"
8'-0"
OVERALL CABINET WIDTH (FIELD VERIFY)
EQ.
SCRIBE
PANEL
1'-6"
TYP.
1'-6"
TYP.
1'-6"
TYP.
1'-6"
TYP.
EQ.
SCRIBE
PANEL
1'-6"
TYP.
EQ.
SCRIBE
PANEL
1'-6"
TYP.
1'-6"
TYP.
1'-6"
TYP.
1'-6"
TYP.
EQ.
SCRIBE
PANEL
1'-6"
TYP.
1'
-
4
"
2'
-
4
"
A6.2
10
SINK AS SCHED.
PROVIDE FALSE
DRAWER PANEL @
SINK .6'
-
8
"
G.C. TO PROVIDE F.R.T. SOLID WOOD
BLOCKING IN PARTITION AS DIRECTED
BY CASEWORK SHOP DRAWINGS.
WALL FINISH AS SCHED.
P.LAM UPPER LEVEL CABINETS
W/ TYP. ALL EXPOSED
SURFACES.
P.LAM SCRIBE PANEL
TYP. BOTH SIDES.
ADJUSTABLE SHELVES
SHOWN DASHED
WALL FINISH AS SCHED.
P.LAM WORK SURFACE TOP AS
DETAILED .
BLACK 1/4" X 1/4" REVEAL.
P.LAM DRAWERS .
P.LAM DOOR PANEL .
P.LAM SCRIBE PANEL
TYP. BOTH SIDES.
ADJUSTABLE SHELVES SHOWN
DASHED.
WALL FINISH AS SCHED.
WALL BASE AS SCHED.
A6.2
9
PL-2
PL-2
PL-1
PL-2
PL-2
PL-2
PL-2
NOTE: CASEWORK DIMENSIONS
INDICATED FOR BASE CABINET (SHOWN
DASHED BELOW) & COUNTERTOP. SEE
ELEVATION FOR DIMENSIONS OF UPPER
CABINETS & MIRROR.
A6.2
3
CASEWORK
CUBBY FOR
STORAGE OF
WORK TOP.
RECESSED
ADJUSTABLE SHELF
LOCATION
NOTE: FINISHED FRONT FACE OF
COUNTERTOP TO ALIGN W/ FINISHED
FRONT FACE OF CABINET BELOW AS
DETAILED. LOFT STATIONS INSTALLED
TIGHT TO ADJACENT GYP. BD. WALL
PARTITION @ ONE SIDE & EXPOSED ON
OPPOSITE SIDE. COORD. ORIENTATION OF
EACH LOFT AS SHOWN ON FLOOR PLAN.
G.C. TO PROVIDE F.R.T. SOLID
WOOD BLOCKING IN
PARTITION AS DIRECTED BY
CASEWORK SHOP DRAWINGS.
1'-5 1/2"1'-6"2'-1"1'-6"1'-5 1/2"
8'-0"
1'
-
1
"
2'-11 1/2"
(TOP)
2'-1"2'-11 1/2"
(TOP)
PLAN VIEW
6"
1'
-
8
"
6"2"
FRONT ELEVATION VIEW
NOTE: SEE PLAN FOR TRUE ORIENTATION.
FINISH ALL EXPOSED SURFACES OF
CASEWORK U.N.O.
P.LAM DRAWER FRONT .
P.LAM DOOR FRONT .
PL-4
PL-4
PL-4
P.LAM WORK SURFACE TOP AS
DETAILED .PL-1
3'
-
0
"
A6.2
8
1'-4"
3'
-
0
"
4"GROMMET LOCATION @ REAR OF
PAY STATION. CENTER ON
COUNTER TOP WIDTH AS SHOWN.
RADIUS WORK SURFACE TOP AS
DIMENSIONED . SCRIBE TO
WALL SURFACE.
CABINET DOOR SWING SHOWN
DASHED BELOW.
PL-1
A6.2
8
3'
-
0
"
6"
2"
1'
-
4
"
3'
-
0
"
3'-4"10"1'-6"10"1'-6"
3'
-
1
"
B.
O
.
M
I
R
R
O
R
F
R
A
M
E
4'
-
8
"
WOOD FRAMED GLASS
MIRROR, CENTER ABOVE SINK.
P.LAM WORK SURFACE TOP
AS DETAILED .
P.LAM CASEWORK FIXTURE
AS DETAILED .
UPPER CABINET DOORS W/
PERIMETER FRAME W/
1/8" FROSTED ACRYLIC PANEL.
1'-5 1/2"1'-6"2'-1"1'-6"1'-5 1/2"
PROVIDE P.LAM FINISHED EDGE @
EXPOSED END OF WORK SURFACE
TOP .
SCRIBE P.LAM TOP TO WALL
AS NECESSARY.
PROVIDE P.LAM FINISH @ EXPOSED
SIDE OF UPPER CABINET .
NOTE: LOFT STATIONS INSTALLED
TIGHT TO ADJACENT GYP. BD. WALL
PARTITION @ ONE SIDE & EXPOSED
ON OPPOSITE SIDE. COORDINATE
ORIENTATION OF EACH LOFT AS
SHOWN ON FLOOR PLAN.
1'
-
6
"
DE
V
I
C
E
EQ.EQ.
LINE OF ADJACENT WALL PARTITION.
LINE OF ADJACENT WALL
PARTITION.
QUADRAPLEX OUTLET: REFER TO ELEC.
DWGS FOR DETAILS. (TYP. BOTH SIDES).
WHERE OUTLETS ARE BACK TO BACK,
OUTLETS IN ONE LOFT TO BE 1'-6" &
OPPOSING LOFT TO BE AT 1'-2".G.C. TO PROVIDE F.R.T. SOLID
WOOD BLKG. IN PARTITION AS
DIRECTED BY CASEWORK SHOP
DRAWINGS.
A6.2
11
A6.2
12
A6.2
4
4'-0"
4 1/2"
WASTE & SUPPLY LINES: REFER TO
PLUMBING DWGS FOR DETAILS.
EQ.EQ.
SURFACE MOUNTED LIGHT
FIXTURE. SEE SHEET A3.0.
5"5"5"5"
5'
-
1
0
"
10 1/2"
EQ.EQ.
PL-2
PL-2
PL-2
PL-1 PL-1
8"DE
V
I
C
E
USB COMBINATION OUTLET: REFER TO ELEC.
DWGS FOR DETAILS. WHERE OUTLETS ARE
BACK TO BACK, STAGGER THEM SIDE BY
SIDE.
HAIR TRAP - MUST BE INSTALLED STRAIGHT
AND TRUE, PERPENDICULAR TO CABINET
FACE. SANITARY ROUGH-IN MUST BE
PROPERLY LOCATED OR WILL BE SUBECT TO
MODIFICATION AT CONTRACTOR'S EXPENSE.
1 1/2"
3
1
/
2
"
1'-5"
1 1/2"
2
3
/
4
"
1'-0"
2'
-
4
"
(2) 'WHITE' MELAMINE ADJUSTABLE
SHELVES.
1'-6"
3'
-
0
"
6"
1'
-
9
"
1"
5
3
/
4
"
1/
4
"
2"
2'
-
6
"
FINISHED FLOOR AS SCHED.
P.LAM COUNTER TOP & EXPOSED SIDE
FACES TO BE FINISHED .
BLACK 1/4" X 1/4" REVEAL.
P.LAM DRAWER W/ FULL
EXTENSION HARDWARE .
1" FINGER PULL. FINISH ALL
SURFACES WITHIN BLACK.
P.LAM DOOR PANEL .
'WHITE' MELAMINE ADJUSTABLE
SHELF.
WALL BASE AS SCHED.
3'
-
0
"
6"
1'
-
9
"
1"
5
3
/
4
"
1/
4
"
2"
2'
-
6
"
P.LAM FALSE DRAWER FRONT
@ SINK .
1'
-
4
"
2'
-
4
"
1'-0"
2'
-
4
"
2'
-
4
"
1'-1"
3'
-
0
"
6"
1'
-
9
"
1"
5
3
/
4
"
1/
4
"
2"
2'
-
6
"
1'-0"
3'
-
0
"
4'-4" A.F.F. (VERIFY)
B.O. UPPER CABINET
1'-0"
1 1/2"
2
3
/
4
"
FINISHED FLOOR AS SCHED.
WOOD FRAMED GLASS MIRROR.
P.LAM COUNTER TOP & EXPOSED SIDE
FACES TO BE FINISHED .
BLACK 1/4" X 1/4" REVEAL.
P.LAM DRAWER W/ FULL
EXTENSION HARDWARE .
1" FINGER PULL. FINISH ALL
SURFACES WITHIN BLACK.
P.LAM DOOR PANEL .
'WHITE' MELAMINE
ADJUSTABLE SHELF.
WALL BASE AS SCHED.
UPPER CABINET DOORS W/
PERIMETER FRAME W/
1/8" FROSTED ACRYLIC PANEL.
2"
2"
1"1"
1"
G.C. TO PROVIDE F.R.T. SOLID WOOD
BLOCKING IN PARTITION AS DIRECTED
BY CASEWORK SHOP DRAWINGS.
WALL PARTITION AS SCHEDULED.
P.LAM UPPER CABINET W/ ALL
EXPOSED SURFACES FINISHED .
UNDER CABINET FINGER PULL .
ALL EXPOSED SURFACE @ UNDERSIDE OF
CABINET TO BE FINISHED .
ALL EXPOSED SURFACE @ UNDERSIDE
OF CABINET TO BE FINISHED .
UNDER CABINET FINGER PULL .
WALL PARTITION AS SCHEDULED.
(2) 'WHITE' MELAMINE ADJUSTABLE
SHELVES.
G.C. TO PROVIDE F.R.T. SOLID WOOD
BLOCKING IN PARTITION AS DIRECTED
BY CASEWORK SHOP DRAWINGS.
WALL PARTITION AS SCHEDULED.
P.LAM UPPER CABINET W/ ALL
EXPOSED SURFACES FINISHED .
UNDER CABINET FINGER PULL .
ALL EXPOSED SURFACE @ UNDERSIDE OF
CABINET TO BE FINISHED .
P.LAM COUNTER TOP & EXPOSED SIDE
FACES TO BE FINISHED .
BLACK 1/4" X 1/4" REVEAL.
1'
-
4
"
FINISHED FLOOR AS SCHED.
1" FINGER PULL. FINISH ALL
SURFACES WITHIN BLACK.
P.LAM DOOR PANEL .
WALL BASE AS SCHED.
1'-6"
(2) 'WHITE' MELAMINE ADJUSTABLE
SHELVES.
WALL PARTITION AS SCHEDULED.
P.LAM UPPER CABINET W/ ALL
EXPOSED SURFACES FINISHED .
G.C. TO PROVIDE F.R.T. SOLID WOOD
BLOCKING IN PARTITION AS DIRECTED
BY CASEWORK SHOP DRAWINGS.
PL-2
PL-2
PL-1
PL-2
PL-2
PL-1
PL-2
PL-2
PL-1
PL-2
PL-2
PL-2
PL-2
PL-2
PL-2
PL-2
PL-2
PL-2
PL-1
1'-6"
(1'-0" @ SIDES)
1'-0"
REAR & SIDE(2)
ELEVATIONS
SECTION
1'-0"
2'-0" A.F.F. (VERIFY)
B.O. UPPER CABINET
(1) 'WHITE' MELAMINE
ADJUSTABLE SHELF.
LOWER CABINET DOORS W/
FINISH. PROVIDE (3)
ADJUSTABLE SHELVES EACH
SECTION.
ALL EXPOSED SURFACE @
UNDERSIDE OF CABINET TO
BE FINISHED .
1"
1'
-
8
"
2"
2"
1
1
/
2
"
3'
-
4
"
5'
-
0
"
WALL MOUNTED P.LAM
CABINETS W/ TYP.
ALL EXPOSED SURFACES
(3) 'WHITE' MELAMINE
ADJUSTABLE SHELVES.
3"W. X 1 1/2"H. OPENING
FOR FINGER PULL TO UPPER
& LOWER DOORS.
1"
WALL PARTITION AS
SCHEDULED.
UPPER CABINET DOORS W/
PERIMETER FRAME W/ 1/8"
FROSTED ACRYLIC PANEL.
PL-2
PL-2
PL-2
PL-2
1'
-
8
1
/
4
"
1'
-
8
1
/
4
"
2
1
/
4
"
P.LAM COUNTER TOP &
EXPOSED SIDE FACES TO BE
FINISHED .
P.LAM DOOR PANEL .
COMMERCIAL GRADE
2 1/2" CASTERS.REAR
PANEL
P.LAM COUNTER TOP &
EXPOSED SIDE FACES TO BE
FINISHED .
P.LAM SIDE(2) & REAR
PANELS .
COMMERCIAL GRADE
2 1/2" CASTERS.
2
1
/
4
"
1
1
/
2
"
3"W. X 1 1/2"H. OPENING
FINGER PULL TO DOORS.
PL-1
PL-2
PL-1
PL-2
PL-2
3'
-
0
"
SHAMPOO BOWL SINK HUNG FROM
P.LAM BACK WALL PANEL TO
DIMENSIONS INDICATED. VENDOR TO
SUPPORT OFF CASEWORK EACH SIDE
SO AS TO SUPPORT SHAMPOO BOWL
SINK FIXTURE AS NECESSARY.
HAIR TRAP (MUST
BE INSTALLED STRAIGHT
& TRUE, PERPENDICULAR
TO CABINET AS
INDICATED, SANITARY
ROUGH-IN MUST BE
PROPERLY LOCATED OR
WILL BE SUBJECT TO
CHANGE UPON REVIEW).
WALL PARTITION
AS SCHEDULED.
SHAMPOO BOWL SINK AS
SCHED. COORD. MOUNTING
DETAILS W/ CUT SHEETS.
1'-1"
FINISHED FACE
TO ALIGN W/ ADJACENT
CASEWORK
P.LAM WORK TOP
IN 'STORED'
POSITION. (SHOWN
DASHED).
WHITE MELAMINE
CASEWORK CUBBY
FOR STORAGE OF
WORK TOP.
1'
-
1
"
WATER SUPPLY & DRAIN
LINES. VFY. ELEV. W/ FIXTURE
CUT SHEETS. (ALL EXPOSED
PIPING SHALL BE CHROME).
2
1
/
2
"
WOOD FRAMED
GLASS MIRROR.
3'
-
0
"
6"
LINE OF CASEWORK
FIXTURE BOTTOM
SHOWN BEYOND.
LINE OF CASEWORK
FIXTURE TOP
SHOWN BEYOND.
2 1/2"
PLUMBING VENT STACK IN WALL.
(SHOWN DASHED). SEE MECH. PLANS
FOR LOCATIONS.
ALL RECESSED CASEWORK SURFACES
TO BE FINISHED W/ WHITE MELAMINE.
WHITE MELAMINE ADJUSTABLE SHELF.
REMOVABLE P.LAM WORK
TOP W/ PREFINISHED 'CUT-OUTS'
FOR FAUCET EQUIP. AS REQ'D.
1'
-
1
0
"
1"
1'
-
7
"
È O
F
D
R
A
I
N
(
V
E
R
I
F
Y
)
1'
-
1
0
"
È O
F
S
U
P
P
L
Y
(
V
E
R
I
F
Y
)
PL-1
PL-2
1'-4"
3'
-
0
"
6"
1'
-
9
"
1"
5
3
/
4
"
1/
4
"
2"
2'
-
6
"
1'-0"
1 1/2"
2
3
/
4
"
FINISHED FLOOR AS SCHED.
P.LAM COUNTER TOP &
EXPOSED SIDE FACES TO BE
FINISHED . SCRIBE TO WALL
SURFACE.
BLACK 1/4" X 1/4" REVEAL.
P.LAM DRAWER W/ FULL
EXTENSION HARDWARE .
1" FINGER PULL. FINISH ALL
SURFACES WITHIN BLACK.
P.LAM DOOR PANEL .
'WHITE' MELAMINE
ADJUSTABLE SHELF.
WALL BASE AS SCHED.
WALL PARTITION AS SCHEDULED.
PL-4
PL-4
PL-1
4"1'-4"
CASEWORK SUPPLIER TO PROVIDE
'WHITE' GROMMET AS SHOWN.
COORDINATE FINAL SIZE REQ'D. W/
OWNER. CENTER ON O.A. COUNTER
WIDTH.
CASEWORK SUPPLIER TO PROVIDE
'BLACK' GROMMET AS SHOWN. VFY.
QUANTITY REQ'D. FOR ADEQUATE
VENTILATION OF TENANT'S EQUIP.
CUT OUT IN BACK PANEL AGAINST WALL
FOR ACCESS TO POWER/DATA OUTLETS
InterlockingRock PANEL WALL ABOVE
PAY STATION.
GENERAL CASEWORK NOTES
1.CASEWORK SUPPLIER TO MANUFACTURE AS REQUIRED FOR CASEWORK TO BE HUNG
SOLELY FROM REAR WALL PARTITION. G.C. TO PROVIDE F.R.T. SOLID WOOD
BLOCKING AS DIRECTED BY MILLWORK SHOP DRAWINGS.
2.ALL INTERIOR SURFACES TO BE 'WHITE' MELAMINE FINISH, TYPICAL.
3.ALL GROMMETS REFERENCED TO BE 'WHITE', TYPICAL.
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
ARCHITECTURAL
CASEWORK DETAILS
A6.2
1
A6.2 1/2"=1'-0"
SPA CABINET ELEVATION 2
A6.2 1/2"=1'-0"
LOFT CABINET / SINK PLAN 3
A6.2 1/2"=1'-0"
LOFT CABINET / SINK ELEVATION
4
A6.2 1"=1'-0"
LOFT CABINET / SINK SECTION 5
A6.2 1"=1'-0"
NAIL UPPER CABINET SECTION 6
A6.2 1"=1'-0"
NAIL PORTABLE CABINET DETAILS
9
A6.2 1"=1'-0"
SPA CABINET SECTION 10
A6.2 1"=1'-0"
SPA CABINET SECTION 11
A6.2 1"=1'-0"
LOFT UPPER CABINET SECTION 12
A6.2 1"=1'-0"
LOFT LOWER CABINET SECTION
7
A6.2 1/2"=1'-0"
PAY STATION ELEVATIONS 8
A6.2 1"=1'-0"
PAY STATION SECTION
3'-0
"
MIN
.
O
V
E
R
L
A
P
DASHED LINE INDICATES (2)
METAL TRACKS ADJOINING
MECHANICAL FASTENERS
TYPICAL WALL TOP TRACK
TYP. METAL STUD FRAMING
OVERLAP AT SPLICE
LIMITING HEIGHT TABLE FOR UNBRACED STUDS
Stud Stud Stud Stud Maximum
Width Type Gauge Spacing Height
1-5/8"158ST25 25 16"9'-6"
158ST25 25 24"7'-3"
2-1/2"212ST25 25 16"12'-6"
212ST25 25 24"10'-9"
212ST22 22 16"13'-0"
212ST22 22 24"11'-6"
212ST20 20 16"14'-0"
212ST20 20 24"12'-3"
3-5/8"358ST25 25 16"16'-0"
358ST25 25 24"13'-6'
358ST22 22 16"17'-3"
358ST22 22 24"15'-0"
358ST20 20 16"18'-3"
358ST20 20 24"16'-0"
6"600ST25 25 16"20'-0"
600ST25 25 24"15'-0"
STUD FRAMING NOTES
1.TABLE BELOW IS BASED ON UNIVERSAL INDUSTRIES, UNIMAST (USG) CORP.'S LIMITING
HEIGHT TABLES FOR UNBRACED STUDS SPACED 16" & 24" O.C. (SYSTEM FOLDER SA-923
1990 EDITION), REQUIREMENT FOR 5 PSF LATERAL PRESSURE & 1/240 ALLOWABLE
DEFLECTION FOR FLEXIBLE FINISHES W/ 1 LAYER OF GYP. BD. PER SIDE OF STUD.
2.SCHEDULED HEIGHTS MAY BE INCREASED BY 50% WHERE THE STUDS ARE DIAGONALLY
BRACED AT THE MAXIMUM HEIGHT POINT TO THE STRUCTURE ABOVE @ 4'-0" O.C.
3.CAUTION! WHEN USING STUDS MANUFACTURED BY A COMPANY OTHER THEN USG,
VERIFY MANUFACTURER'S STUD STRENGTH AND LIMITING HEIGHT. ADJUST GAUGE &
MAXIMUM HEIGHT RECOMMENDED BY MFR.'S CURRENT PRINTED SPECIFICATION.
4.SEE DETAIL 3/A6.3 FOR TYPICAL METAL FRAMING CONFIGURATION AT TOP OF WALL
WHERE TWO TOP TRACKS ADJOIN.
a.SEE TYP. WALL FRAMING FOR GAUGE OF STUDS. VERIFY LENGTH, HEIGHT,
LOCATION OF BACKING PLATE, & NUMBER.
b.REQUIRED WITH ACCESSORY MANUFACTURERS. USE #12 SELF TAPING SHEET
METAL SCREWS WHEN ATTACHING ITEMS TO BACKING PLATE.
c.WALL STUD FLANGES ARE CONTINUOUS AT BACKING PLATE.
1/
2
"
D
E
E
P
G
A
P
CONT. 3 5/8" X 20 GA. TRACK WITH
(1) #12 SCREW IN EACH FLANGE OF
EACH STUD
CONT. 18 GA DEEP LEG DEFLECTION
TRACK (1 1/2" MIN. DEEP LEGS).
CONNECT TO ROOF STRUCTURE
WITH (2) #12 SCREWS @ 16" O.C.
NOTE: ALL CONNECTIONS TO
STRUCTURE ABOVE TO BE
ATTACHED TO TOP CHORD
OF STEEL TRUSS OR TO A
HORIZONTAL MOUNTING
PLATE RUNNING BETWEEN
THE TOP CHORD OF STEEL
TRUSSES. DO NOT ATTACH
TO DECK.
UNDERSIDE OF FLOOR OR ROOF
STRUCTURE ABOVE. SEE GENERAL
"NOTE" ON ATTACHMENT BELOW.
P.LAM COUNTER
TOP & EXPOSED
SIDE FACES TO BE
FINISHED .
BLACK 1/4" X 1/4"
REVEAL.
P.LAM DRAWER
W/ FULL
EXTENSION
HARDWARE .
PL-1
CASEWORK SUPPLIER TO
PROVIDE 'WHITE' GROMMET AS
SHOWN. COORDINATE FINAL
SIZE REQ'D. W/ OWNER. CENTER
ON O.A. COUNTER WIDTH.
CUT OUT IN BACK PANEL
AGAINST WALL FOR ACCESS TO
POWER/DATA OUTLETS
1 1/2"4"
4'
-
8
"
2'
-
7
"
5"
B1
3/4" MDO
PLYWD. SHALL
BE .PL-4
PREFIN. 3/4"
MDO PLYWD.
WAY FINDING
WALL, ALL
SIDES .PL-4
4"5"1'-1"
1'
-
1
1
"
1"
5
3
/
4
"
1/
4
"
2"
1'-0"
8"
1 1/2"
2
3
/
4
"
1'-4 1/2"
4"
1" FINGER PULL.
FINISH ALL SURFACES
WITHIN BLACK.
P.LAM DOOR
PANEL .
'WHITE' MELAMINE
ADJUSTABLE SHELF.
PL-4
PL-4
ALL EXPOSED
3/4" MDO
PLYWD. SHALL
BE .PL-4
ALL INTERIOR
SURFACES TO BE
'WHITE' MELAMINE
FINISH, TYP.
1 1/2"4"
B1
POWER & DATA
FROM UNDER
SLAB- SEE ELEC.
PLANS.
PL-4 A6.3
11PREFINISHED 3/4" MDO PLYWD.
WAY FINDING WALL, ALL SIDES .
3/
4
"
3
1
/
2
"
1'-11"1'-11"
PL-1CABINET DOOR SWING SHOWN
DASHED BELOW.
'WHITE' GROMMET LOCATION @
REAR OF PAY STATION. CENTER
ON COUNTER TOP WIDTH AS
SHOWN.
NOTE: CASEWORK CONTRACTOR
TO COORDINATE WITH G.C. FOR
G.C. PROVIDED STL. REQ'D. TO
STIFFEN MILLWORK.
1'
-
0
"
A4.2
7
A4.2
8 LED/LCD
DISPLAY ON
WALL MOUNT.
G.C. TO COORD.
POWER / DATA
REQ'D. WITH
CASEWORK
SUPPLIER &
ELECTRICAL
CONTRACTOR.
NO EXPOSED
OUTLETS OR
CONDUIT /
WIRES
PERMITTED.
TO
P
OF
DI
S
P
L
A
Y
SALON LOFTS
GRAPHIC PUCK
SUPPLIED &
INSTALLED BY
SALON LOFTS.
LED/LCD DISPLAY ON WALL MOUNT.
G.C. TO COORD. POWER / DATA
REQ'D. WITH CASEWORK SUPPLIER
& ELECTRICAL CONTRACTOR. NO
EXPOSED OUTLETS OR CONDUIT /
WIRES PERMITTED.
3/4"3 1/2"3/4"
3/
4
"
1'
-
8
1
/
2
"
3/
4
"
1'
-
1
0
"
WAY FINDING MILLWORK BY
CASEWORK SUPPLIER. G.C. TO
COORDINATE & INSTALL AS REQ'D.
PULL-OUT CHECK
LEDGE .
4'-8"
OUTLET & DATA
JUNCTION BOX
FOR PAY
STATION
EQUIPMENT-
SEE ELEC.
2'
-
0
"
OUTLET & DATA
JUNCTION BOX
FOR LED/LCD
DISPLAY-
SEE ELEC.
4'
-
0
"
3
1
/
2
"
PULL OUT CHECK
LEDGE .PL-1
PL-4 A6.3
10
A4.2
7
WAY FINDING MILLWORK BY
CASEWORK SUPPLIER. G.C. TO
COORDINATE & INSTALL AS REQ'D.
3'-10"5"5"
4
7
/
8
"
PAINTED GYP. BD. WALL FINISH AS SCHED.
FASTEN WAY FINDING MILLWORK BACK
TO WALL AS REQ'D.
1 1/2"4"
4'
-
8
"
2'
-
7
"
5"
B1
ALL EXPOSED 3/4" MDO
PLYWD. SHALL BE .PL-4
PREFIN. 3/4" MDO PLYWD.
WAY FINDING WALL, ALL
SIDES .PL-4
4"4 1/4"
4 1/4"4"
LED/LCD DISPLAY ON WALL
MOUNT. G.C. TO COORD.
POWER / DATA REQ'D. WITH
CASEWORK SUPPLIER &
ELECTRICAL CONTRACTOR.
NO EXPOSED OUTLETS OR
CONDUIT / WIRES PERMITTED.
TO
P
OF
DI
S
P
L
A
Y
SALON LOFTS GRAPHIC PUCK
SUPPLIED & INSTALLED BY
SALON LOFTS.
OUTLET & DATA JUNCTION
BOX FOR LED/LCD DISPLAY.
POWER / DATA FROM WALL
BEHIND. SEE ELEC. PLANS.
4'
-
0
"
FLOOR
InterlockingRock PANELS .M24
3
1
/
2
"
3/
4
"
NOTE: CASEWORK CONTRACTOR
TO COORDINATE WITH G.C. FOR
G.C. PROVIDED STL. REQ'D. TO
STIFFEN MILLWORK.
PREFINISHED 3/4" MDO PLYWD.
WAY FINDING WALL, ALL SIDES .
LED/LCD DISPLAY ON WALL MOUNT.
G.C. TO COORD. POWER / DATA
REQ'D. WITH CASEWORK SUPPLIER
& ELECTRICAL CONTRACTOR. NO
EXPOSED OUTLETS OR CONDUIT /
WIRES PERMITTED.
3/4"3 1/2"3/4"
3/
4
"
7
1
/
2
"
8
1
/
4
"
InterlockingRock PANELS
(TYP. AT EACH SIDE).
M24
T.O. / WALL FINISH
EL.=9'-6" A.F.F. / SEE FINISH PLAN
PARTITION/DEMISING WALL AS SCHED.
WALL FINISH AT WALLS TO EXIST. ROOF DECK
P2
P1/P6 (VARIES / VERIFY)
P1 P6
P2
P1
/
P
6
(V
F
Y
.
)
TAPED-IN MTL. 'J' BEAD OR 'TEAR STRIP' EA.
SIDE OF WALL- PROVIDED & INSTALLED BY G.C.
2"
T.O. GYP. BD.
EL.=9'-6" A.F.F.
SEE PLAN
PARTITION WALL AS SCHED.
WALL FINISH AT PARTIAL HEIGHT WALLS
CONDUITS TO BE CONCEALED IN WALL
TROUGH. CONDUIT IS NOT TO BE EXPOSED
UNLESS NOTED OTHERWISE, TYP.
CONT. 20 GA. DEEP LEG TRACK (UPSIDE
DOWN- 2" DEEP LEGS) CONNECTED TO
MTL. STUD WALL FRAMING TOP TRACK.
SEE ELEVATIONS FOR
LOCATIONS & SIZES REQ'D.
ELEC. CONTRACTOR TO INSTALL
LINEAR LED FLEX FIXTURES TO
MILLWORK LOCATED SUCH
THAT OWNER SUPPLIED
GRAPHIC PANEL CAN BE
INSTALLED IMMEDIATELY
ADJACENT TO LIGHT FIXTURES
AS INDICATED. COORDINATE
EXACT FIXTURE PLACEMENT ON
SITE TO MAXIMIZE LIGHT
THROW FROM FIXTURE ONTO
ADJACENT WALL SURFACES.
1/4"
PROTECT EXPOSED P.LAM
EDGES FROM DAMAGE.
GR
A
P
H
I
C
P
A
N
E
L
3"
RUN AT BACKSIDE AND
EDGES (PROJECTING 1/4" PAST
FRONT FACE OF PANEL) OF
GRAPHIC DISPLAY PANEL.
PL-3
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
ARCHITECTURAL
DETAILS
A6.3
1
A6.3 N.T.S.
STUD LIMITS & FRAMING NOTES 2
A6.3 1 1/2"=1'-0"
NON-RATED DEFLECTION DETAIL 3
A6.3 1/2"=1'-0"
METAL FRAMING SPLICE DETAIL
6
A6.3
NOT USED 7
A6.3 1 1/2"=1'-0"
ENLARGED WAY FINDING MILLWORK PLAN
8
A6.3
NOT USED 11
A6.3 1"=1'-0"
WAY FINDING MILLWORK SECTION10
A6.3 1"=1'-0"
WAY FINDING MILLWORK SECTION9
A6.3 1 1/2"=1'-0"
ENLARGED WAY FINDING MILLWORK PLAN
4
A6.3 3"=1'-0"
PARTIAL HEIGHT WALL DETAILS 5
A6.3 6"=1'-0"
GRAPHIC DISPLAY DETAIL
A6.0
3sim.
WALL FINISH TRANSITION
AS SCHEDULED.
FINISHES RETURN/ WRAP
JAMB, TYP.
NOTE: SEE PLAN FOR TRUE CONFIGURATION.
WALL FINISH AS SCHED.
1/2" CLEAR
TEMPERED GLAZING.
LINE OF FINISHED
FLOOR.A6.0
9sim.WALL BASE AS SCHED.
GLAZING BASE.
FIN. WDW. HEAD
EL. = 7'-10"
TOP OF FLOOR
EL. = 0'-0"
4'-0" (3'-0" @ SIM.)
FINISHED OPENING
VFY. W/ SHEET A2.0 3"3"
A6.4
3
TOP OF WALL
EL. = 9'-6"F.R.T. SOLID 2x WD. BLKG. SHOWN
DASHED AS REQ'D. FOR DOOR
HARDWARE INSTALLATION, TYP.
HEAVY DUTY TRACK MECH. FASTENED
TO F.R.T. 2x WD. BLKG. IN WALL
PARTITION PER MFR. INSTRUCTIONS.
NOTE: SEE ELEVATIONS
FOR TRACK LOCATIONS.
BUMPER STOP AT EA. END OF
TRACK BY TRACK SUPPLIER.
A
B
C
FOR TYP. NOTES AND
INFORMATION, REFER TO
LOFT TRACK BLOCKING
ELEVATION A.
6'-10"
5"EQUAL
EQ.
TYP.
EQ.
TYP.EQ
.
TY
P
.
EQ
.
TY
P
.
5"EQUAL
10'-0"
5"EQUAL EQUAL EQUAL 5"
EQ.
TYP.
EQ.
TYP.EQ
.
TY
P
.
EQ
.
TY
P
.
A
8'-6"
5"EQUAL EQUAL 5"EQUAL
FOR TYP. NOTES AND
INFORMATION, REFER TO
LOFT TRACK BLOCKING
ELEVATION A.
2
1
/
4
"
T.
O
.
D
O
O
R
EQ.
TYP.
EQ.
TYP.EQ
.
TY
P
.
EQ
.
TY
P
.
2
1
/
4
"
T.
O
.
D
O
O
R
2
1
/
4
"
T.
O
.
D
O
O
R
D
FOR TYP. NOTES AND
INFORMATION, REFER TO
LOFT TRACK BLOCKING
ELEVATION A.
5"EQUAL 5"EQUAL
6'-0"
EQ.
TYP.
EQ.
TYP.EQ
.
TY
P
.
EQ
.
TY
P
.
2
1
/
4
"
T.
O
.
D
O
O
R
LIGHT PER SCHED.-
SUSPENDED FROM
STRUCT. ABOVE.
B.O. GYP. BD.
9'-0" A.F.F.
T.O. GYP. BD.
9'-6" A.F.F.
THREADED ROD
HANGERS @ MAX.
4'-0" O.C. DESIGN
& CONNECTIONS
TO MTL. STUDS
BY OTHERS. SEE
DETAIL 5/A6.1
PAINT .
VARIES/
SEE PLAN
EXISTING STEEL
JOISTS. G.C. TO
VFY. LOCATIONS,
TYPICAL.
PAINT .
UNI-STRUT FRMG. OR APPROVED EQ. AT
THREADED ROD HANGERS, TYP. DESIGN
BY OTHERS. PAINT .P2
6"
P2
P3P3P3
P2
5/8" GYP. BD. ON
3 5/8" MTL. STUD
@ 24" O.C. SOFFIT
FRMG. W/ MTL.
CORNER BEADS
AND / OR 'TEAR
STRIPS' AS REQ'D.
VARIES/
SEE PLAN
3"3"
TYP. ALL
SIDES7" WHERE
INDICATED- SEE
DETAIL 6/A6.4.
4'-0" (3'-0" @ SIM.)
VERIFY W/ SHEET A2.0
"LOFT" SIDE
A6.4
2
NOTE: SEE PLAN FOR
TRUE CONFIGURATION.
WALL SYSTEM AS SCHEDULED.
LINE OF FLOOR FINISH BELOW,
SEE FINISH PLAN FOR DETAILS.
GLAZING BASE AS NOTED,
SEE DETAIL 9SIM./A6.0.
LINE OF SOFFIT / HEADER CONSTR.
ABOVE SHOWN DASHED.
"HALLWAY" SIDE
4"
TY
P
.
3"3"
F1
F2
6"
LED LINEAR WALL WASH FIXTURE
WITH ADJUSTABLE HINGED CLIP
(LENGTHS AS INDICATED ON SHEET
A3.0) SUPPLIED BY SALON LOFTS &
INSTALLED BY G.C. TO FACE OF
FLOATING GYP. BD. CEILING. CENTER
& ANGLE FIXTURE ALONG
InterlockingRock PANELS. COORD.
EXACT MOUNTING LOCATION WITH
SALON LOFTS' REPRESENTATIVE.
1"
7"
InterlockingRock PANELS
OVER GYP. BD. WALL SURFACE FROM
3'-0" A.F.F. TO 9'-6" A.F.F. INSTALL
PER MFR'S. INSTRUCTIONS. PAINT
(FLAT).
M24
P3
SATIN ALUM. (AE) TILE
EDGE TRIM -
SCHLUTER-RENO RAMP.
F1EXIST. CONC. FLOOR /
VINYL SHEET FLOOR
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
ARCHITECTURAL
DETAILS
A6.4
2
A6.4 1/2"=1'-0"
GLAZING ELEVATION 3
A6.4 1 1/2"=1'-0"
ENLARGED GLAZING PLAN1
A6.4 3/4"=1'-0"
LOFT TRACK BLOCKING ELEVATIONS 4
A6.4 6"=1'-0"
FLOOR TRANSITION DETAIL
5
A6.4 1"=1'-0"
SOFFIT DETAIL 6
A6.4 3"=1'-0"
DISPLAY WALL LIGHTING DETAIL
TABLE OF CONTENTS
DIVISION 0: CONDITIONS OF THE CONTRACT
00700 GENERAL CONDITIONS (AIA A201-1997)
00800 SUPPLEMENTARY CONDITIONS
DIVISION 1: GENERAL REQUIREMENTS
01100 SUMMARY OF WORK
01300 ADMINISTRATIVE REQUIREMENTS
01400 QUALITY REQUIREMENTS
01500 TEMPORARY FACILITIES AND CONTROLS
01600 PRODUCT REQUIREMENTS
01630 SUBSTITUTIONS AND PRODUCT OPTIONS
01700 EXECUTION REQUIREMENTS
01735 SELECTIVE DEMOLITION
01800 SYSTEMS DEMONSTRATION
DIVISION 2:SITE CONSTRUCTION (NOT USED)
DIVISION 3:CONCRETE
03300 CAST-IN PLACE CONCRETE
03540 CEMENTITIOUS UNDERLAYMENT
DIVISION 4:MASONRY (NOT USED)
DIVISION 5:METALS
05500 METAL FABRICATIONS
05700 ORNAMENTAL METALS
DIVISION 6: WOOD AND PLASTICS
06105 MISCELLANEOUS ROUGH CARPENTRY
06200 FINISH CARPENTRY
06400 ARCHITECTURAL WOODWORK
DIVISION 7:THERMAL AND MOISTURE PROTECTION
07210 INSULATION
07560 ROOF REPAIRS
07600 FLASHING AND SHEET METAL
07810 PATCHING EXISTING FIREPROOFING
07840 FIRESTOPPING
07900 JOINT SEALERS
DIVISION 8:DOORS AND WINDOWS
08110 STEEL DOORS AND FRAMES
08200 WOOD DOORS AND FRAMES
08310 ACCESS DOORS AND PANELS
08411 ALUMINUM FRAMED ENTRANCES & STOREFRONTS
08620 UNIT SKYLIGHTS
08700 HARDWARE
08810 GLAZING
DIVISION 9:FINISHES
09260 GYPSUM BOARD ASSEMBLIES
09300 TILE
09510 ACOUSTICAL CEILINGS
09650 RESILIENT TILE FLOORING
09655 RESILIENT SHEET FLOORING
09680 CARPET
09900 PAINTS AND COATINGS
DIVISION 10: SPECIALTIES
10520 FIRE EXTINGUISHER AND CABINETS
10810 TOILET ACCESSORIES
DIVISION 11: EQUIPMENT (NOT USED)
DIVISION 12: FURNISHINGS (NOT USED)
DIVISION 13: SPECIAL CONSTRUCTION (NOT USED)
DIVISION 14: CONVEYING SYSTEMS (NOT USED)
DIVISION 15: MECHANICAL (REFER TO MECHANICAL DRAWINGS)
DIVISION 16: ELECTRICAL (REFER TO ELECTRICAL DRAWINGS)
DIVISION ZERO: CONDITIONS OF THE CONTRACT
SECTION 00700 - GENERAL CONDITIONS
A. GENERAL CONDITIONS: THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201,
1997 EDITION, IS A PART OF THIS CONTRACT, AND SHALL GOVERN WORK.
1.A COPY WILL BE MADE AVAILABLE BY ARCHITECT UPON REQUEST.
SECTION 00800 - SUPPLEMENTARY CONDITIONS
A.CONDITIONS AND REQUIREMENTS: GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND DIVISION 1,
GENERAL REQUIREMENTS CONTAIN INFORMATION NECESSARY FOR COMPLETION OF EVERY PART OF PROJECT.
B.DIVISION 1: WHERE PROVISIONS OF GENERAL CONDITIONS RELATE TO PROJECT ADMINISTRATION OR
WORK-RELATED REQUIREMENTS OF THE CONTRACT, THOSE PARAGRAPHS ARE EXPANDED IN DIVISION 1.
C.SUBCONTRACTORS: CONTRACTOR AGREES TO BIND SUBCONTRACTORS AND MATERIAL SUPPLIERS TO TERMS OF
GENERAL AND SUPPLEMENTARY CONDITIONS, INCLUDING ARBITRATION.
D.PAYMENTS: SEE CONSTRUCTION CONTRACT.
E.INSURANCE: AS APPROVED BY LANDLORD/TENANT.
F.MISCELLANEOUS DEFINITIONS:
1.APPROVED: REQUIRES WRITTEN ACTION BY ARCHITECT AS DOES TERMS SUCH AS DIRECTED, SELECTED,
REQUIRED, ORDERED, DESIGNATED, ACCEPTED, ACCEPTABLE, AND SATISFACTORY.
2.FURNISH: SUPPLY AND DELIVER TO PROJECT, UNLESS OTHERWISE STATED IN GREATER DETAIL.
3.INSTALL: OPERATIONS AT PROJECT, FROM INSPECTING AND UNLOADING, TO COMPLETION IN PLACE, READY
FOR INTENDED USE.
4.PROVIDE: FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE, UNLESS OTHERWISE STATED IN
GREATER DETAIL.
DIVISION ONE: GENERAL REQUIREMENTS
SECTION 01100 - SUMMARY OF WORK
A.SCOPE: PROJECT CONSISTS OF CONSTRUCTION OF THE 'SALON LOFTS' FACILITY AS INDICATED IN CONTRACT
DOCUMENTS.
1.ITEMS NOTED "NIC" (NOT IN CONTRACT) WILL BE FURNISHED AND INSTALLED BY LANDLORD/TENANT OR
UNDER SEPARATE CONTRACT.
2.HAZARDOUS MATERIALS: NOT IN CONTRACT; LANDLORD WILL PROVIDE FOR HANDLING OF HAZARDOUS
MATERIALS UNDER SEPARATE CONTRACT PRIOR TO THIS PROJECT. IF HAZARDOUS MATERIALS ARE SUSPECTED,
NOTIFY OWNER IMMEDIATELY.
B.WORK SEQUENCE: COORDINATE CONSTRUCTION SCHEDULE, OPERATIONS AND USE OF PREMISES WITH BUILDING
MANAGEMENT.
C.CONTRACTOR USE OF PREMISES: LIMIT TO AREAS INDICATED ON DRAWINGS AND AS SPECIFIED; LIMIT ACCESS AS
DIRECTED BY TENANT & LANDLORD.
D.LINES AND LEVELS ENGINEERING: ESTABLISH LINES AND LEVELS BY USE OF RECOGNIZED ENGINEERING PRACTICES.
LOCATE AND PROTECT CONTROL AND REFERENCE POINTS.
E.REGULATORY REQUIREMENTS: PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH APPLICABLE CODES. COMPLY
WITH CODE REQUIREMENTS FOR CONSTRUCTION. INFORM ARCHITECT OF DISCREPANCIES OBSERVED OR NOTED BY
OTHERS.
F.STANDARDS: COMPLY WITH STANDARDS REFERENCED EXCEPT WHERE MORE RIGID REQUIREMENTS ARE REQUIRED
BY CODE. DATE OF STANDARD IS THAT IN EFFECT AS OF DATE DOCUMENTS ARE ISSUED, EXCEPT WHEN SPECIFIC
DATE IS SPECIFIED.
G.TENANT FURNISHED CONTRACTOR INSTALLED ITEMS: TENANT WILL ARRANGE FOR AND PAY FOR PRODUCT AS
INDICATED ON DRAWINGS TO BE DELIVERED TO PROJECT SITE FOR CONTRACTOR INSTALLATION.
1.CONTRACTOR SHALL INSPECT, RECEIVE, UNLOAD, STORE, INSTALL AND FINISH.
SECTION 01300 - ADMINISTRATIVE REQUIREMENTS
A.PROCEDURES: CONTRACTOR SHALL REVIEW AND APPROVE SUBMITTALS PRIOR TO SUBMITTING TO TENANT'S
PROJECT MANAGER; INFORM TENANT'S PROJECT MANAGER IN WRITING AT TIME OF SUBMISSION OF ANY
PROPOSED DEVIATION FROM CONTRACT DOCUMENTS.
1.SUBMITTAL BY CONTRACTOR REPRESENTS THAT FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA,
MATERIALS, CATALOG NUMBERS AND SIMILAR DATA HAVE BEEN DETERMINED AND VERIFIED BY CONTRACTOR.
2.REVIEW OF SUBMITTALS BY TENANT'S PROJECT MANAGER SHALL BE FOR DESIGN CONCEPT ONLY AND SHALL
NOT BE CONSTRUED AS APPROVING DEPARTURES FROM CONTRACT DOCUMENTS.
B.CONSTRUCTION PROGRESS SCHEDULE: BAR CHARTS OR CONTRACTOR'S STANDARD COMPUTERIZED SCHEDULES,
UPDATED REGULARLY, NO LESS THAN MONTHLY.
C.SCHEDULE OF VALUES: AIA FORM G703 OR APPROVED FORMAT.
D.SHOP DRAWINGS: SUBMIT THREE PRINTS; PROVIDE FOR CUSTOM PRODUCTS AND PRODUCTS NOT FULLY IDENTIFIED
BY PRODUCT DATA.
E.PRODUCT DATA: SUBMIT NUMBER REQUIRED BY CONTRACTOR PLUS TWO FOR TENANT'S PROJECT MANAGER;
INDICATE ITEM TO BE USED WHERE DATA FOR MORE THAN ONE PRODUCT OR OPTION IS INCLUDED; PROVIDE FOR
EACH STOCK MANUFACTURED ITEM.
F.SAMPLES: PROVIDE SAMPLES FOR EACH TYPE OF EXPOSED FINISH, COLOR, AND TEXTURE; MINIMUM SIZE 6",
MAXIMUM SIZE 12" UNLESS OTHERWISE SPECIFIED; SUBMIT ONE SAMPLE FOR ARCHITECT TO RETAIN, ONE SAMPLE
FOR FIELD OFFICE, AND NUMBER REQUIRED BY CONTRACTOR.
G.MANUFACTURER'S CERTIFICATES: PROVIDE TWO.
H.COORDINATION: COORDINATE USE OF PREMISES AND ACCESS TO SITE UNDER DIRECTION OF LANDLORD/TENANT;
COORDINATE WORK TO ASSURE EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF CONSTRUCTION
ELEMENTS.
1.MAKE PROVISIONS FOR TENANT INSTALLED ITEMS AND FOR SEPARATE CONTRACTS.
2.VERIFY CHARACTERISTICS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK
HAVING INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTION TO, AND PLACING SUCH
EQUIPMENT IN SERVICE.
3.COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK; CONCEAL
PIPES, DUCTS, AND WIRING IN FINISHED AREAS; COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH
FINISHES.
I.PROJECT MEETINGS: SCHEDULE AND ADMINISTER MEETINGS, MAKE PHYSICAL ARRANGEMENT, PREPARE AGENDA,
PRESIDE AT MEETINGS AND RECORD MINUTES.
SECTION 01400 - QUALITY REQUIREMENTS
A.GENERAL: MAINTAIN QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, PRODUCTS, SERVICES, SITE
CONDITIONS AND WORKMANSHIP.
B.MANUFACTURER'S FIELD SERVICES: WHEN SPECIFIED IN RESPECTIVE SPECIFICATION SECTIONS, REQUIRE
MANUFACTURER OR SUPPLIER TO HAVE QUALIFIED PERSONNEL PROVIDE ON-SITE OBSERVATIONS AND
RECOMMENDATIONS.
1.REPRESENTATIVE SHALL:
A. OBSERVE FIELD CONDITIONS, INCLUDING CONDITIONS OF SURFACES. OBSERVE QUALITY OF
WORKMANSHIP AND METHODS OF INSTALLATION.
B. PROVIDE RECOMMENDATIONS FOR INSTALLATION AND WORKMANSHIP.
C. WHERE REQUIRED, START, TEST, AND ADJUST EQUIPMENT AS APPLICABLE.
D. SUBMIT WRITTEN REPORT TO TENANT'S PROJECT MANAGER OF OBSERVATIONS.
C.MOCK-UPS: CONSTRUCT FIELD SAMPLES AND MOCK-UPS ON SITE AS REQUIRED.
D.TESTING LABORATORY SERVICES: TESTING SHALL BE BY AN APPROVED TESTING LABORATORY, AS REQUIRED BY
SPECIFICATIONS AND BY APPLICABLE CODES.
1.TESTING REQUIRED WILL BE PAID FOR BY TENANT EXCEPT RETESTING WILL BE PAID FOR BY CONTRACTOR
WHERE REQUIRED BY FAILURE TO MEET ORIGINAL TESTS.
2.CONTRACTOR SHALL FURNISH MATERIALS AND SAMPLES FOR TESTS AND SHALL ASSIST TESTING LABORATORY
AS REQUESTED.
SECTION 01500 - TEMPORARY FACILITIES AND CONTROLS
A.GENERAL: PROVIDE TEMPORARY CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS AS REQUIRED TO
COMPLETE PROJECT IN ACCORDANCE WITH CONTRACT DOCUMENTS AND TO CONFORM WITH REQUIREMENTS OF
APPLICABLE AUTHORITIES.
1.CONTRACT GOVERNING AUTHORITIES TO ESTABLISH EXTENT OF TEMPORARY FACILITIES AND TEMPORARY
CONTROLS REQUIRED BY AUTHORITIES.
B.TEMPORARY POWER: PROVIDE POWER SERVICE AND LIGHTING REQUIRED FOR OPERATIONS, WITH BRANCH WIRING
AND DISTRIBUTION BOXES LOCATED TO ALLOW SERVICE AND LIGHTING BY MEANS OF CONSTRUCTION-TYPE POWER
CORDS.
C.TEMPORARY WATER AND SANITARY SERVICES: PROVIDE AND MAINTAIN REQUIRED DRINKING WATER AND
SANITARY FACILITIES WITH ENCLOSURES.
D.NOISE, DUST, AND POLLUTION CONTROL: PROVIDE MATERIALS AND EQUIPMENT NECESSARY TO COMPLY WITH
LOCAL REQUIREMENTS FOR NOISE, DUST, AND POLLUTION CONTROL.
E.BARRIERS: PROVIDE AS REQUIRED TO PROTECT ADJACENT PROPERTIES FROM DAMAGE FROM OPERATIONS; AND AS
REQUIRED BY GOVERNING AUTHORITIES.
1.FENCE: MINIMUM 8'-0" COMMERCIAL CHAIN LINK OR SOLID WOOD CONSTRUCTION FENCE; EQUIP WITH GATES
WITH LOCKS. SEE PLANS.
2.SECURITY: MAINTAIN SITE AND MATERIALS SECURE DURING CONSTRUCTION PERIOD.
F.CLEANING: CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH; DISPOSE OF OFF-SITE AT INTERVALS
APPROVED BY TENANT'S PROJECT MANAGER AND ACCEPTABLE TO APPLICABLE AUTHORITIES.
G.SIGNS: SUBJECT TO APPROVAL OF TENANT'S PROJECT MANAGER.
H.FIELD OFFICE: PROVIDE WEATHER-TIGHT FIELD OFFICE, WITH LIGHTING, ELECTRICAL OUTLETS, HEATING, AND
VENTILATING EQUIPMENT, AND EQUIPPED WITH FURNITURE.
1.TELEPHONE SERVICE: PROVIDE TELEPHONE SERVICE AND FAX SERVICE TO SITE DURING ON-SITE CONSTRUCTION
OPERATIONS.
2.TELEPHONE SERVICE: PROVIDE CELLULAR PHONE WITH ON-SITE PERSON IN CHARGE; PROVIDE PHONE NUMBER
TO TENANT'S PROJECT MANAGER.
I.STORAGE: LIMIT ON-SITE STORAGE TO AREAS DESIGNATED FOR CONSTRUCTION OPERATIONS AND APPROVED IN
WRITING IN ADVANCE BY TENANT; PROVIDE ADDITIONAL WEATHER-TIGHT, SECURED OFF-SITE STORAGE AS
REQUIRED.
J.REMOVAL AND CLEANING: REMOVE CONSTRUCTION FACILITIES, CLEAN AND REPAIR DAMAGE, IN EXCESS OF
CONTRACT REQUIREMENTS, CAUSED BY OPERATIONS OR USE OF TEMPORARY FACILITIES.
SECTION 01600 - PRODUCT REQUIREMENTS
A.CONTRACT AMOUNT: BASE ON MATERIALS AND PRODUCTS IN CONTRACT DOCUMENTS; WHERE LISTED IN
CONTRACT DOCUMENTS, MATERIALS AND PRODUCTS BY MANUFACTURERS NOT LISTED SHALL NOT BE USED
WITHOUT WRITTEN APPROVAL.
B.PRODUCTS: COMPONENTS SUPPLIED IN QUANTITY SHALL BE INTERCHANGEABLE; PROVIDE NEW MATERIALS UNLESS
OTHERWISE DIRECTED IN CONTRACT DOCUMENTS.
C.INSTALLATION: INSTALL ITEMS PLUMB, LEVEL AND SECURE, AND IN CORRECT RELATION TO ADJACENT PRODUCTS;
SECURE IN PLACE WITH POSITIVE ANCHORAGE DEVICES DESIGNED AND SIZED TO WITHSTAND STRESSES, VIBRATION,
AND RACKING.
1.COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS EXCEPT WHERE
MORE STRINGENT REQUIREMENTS ARE SPECIFIED.
D.TRANSPORTATION: TRANSPORT PRODUCTS TO AVOID PRODUCT DAMAGE, DELIVER IN UNDAMAGED CONDITION IN
MANUFACTURER'S UNOPENED CONTAINERS OR PACKAGING.
E.HANDLING: PROVIDE EQUIPMENT AND PERSONNEL TO HANDLE PRODUCTS BY METHODS TO PREVENT SOILING AND
DAMAGE; PROMPTLY INSPECT TO ASSURE PRODUCTS ARE CORRECT, COMPLETE, AND UNDAMAGED, AND
QUANTITIES ARE CORRECT.
F.STORAGE: STORE MATERIAL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS, WITH SEALS AND LABELS
INTACT AND LEGIBLE.
G.PROTECTION: PROVIDE COVERINGS TO PROTECT PRODUCTS FROM DAMAGE FROM TRAFFIC AND CONSTRUCTION
OPERATIONS, REMOVE WHEN NO LONGER NEEDED.
H.SPECIFIED PRODUCTS: FOR PRODUCTS SPECIFIED BY NAMING ONE OR MORE PRODUCTS OR MANUFACTURERS,
SELECT PRODUCTS OF ANY NAMED MANUFACTURER MEETING SPECIFICATIONS.
SECTION 01630 - SUBSTITUTIONS AND PRODUCT OPTION
A.SUBSTITUTIONS AND PRODUCT OPTIONS: PROVIDE PRODUCTS INDICATED OR APPROVED; REQUESTS FOR
SUBSTITUTIONS OF OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IN WRITING.
1.CONTRACTOR OPTIONS: PROVIDE PRODUCTS AND MANUFACTURERS NAMED IN SPECIFICATIONS, SUBMIT
REQUEST FOR SUBSTITUTION FOR PRODUCTS AND MANUFACTURERS NOT SPECIFICALLY NAMED WHERE
NAMES ARE LISTED.
2.SUBSTITUTIONS: CONTRACTOR SHALL INVESTIGATE PROPOSED SUBSTITUTIONS AND DETERMINE IF
EQUIVALENT TO PRODUCTS SPECIFIED. SUBMITTALS SHALL INCLUDE COST OR TIME BENEFITS FOR
SUBSTITUTIONS; FAILURE TO INDICATE COST OR TIME BENEFIT IS JUSTIFICATION FOR REJECTION.
3.CONTRACTOR'S REPRESENTATION: REQUESTS CONSTITUTE THAT CONTRACTOR HAS INVESTIGATED PROPOSED
PRODUCTS AND DETERMINES IT MEETS OR EXCEEDS SPECIFIED PRODUCTS AND WAIVES CLAIMS FOR
ADDITIONAL COSTS THAT SUBSEQUENTLY BECOME APPARENT.
4.ARCHITECT'S DUTIES: TENANT'S PROJECT MANAGER SHALL BE JUDGE OF ACCEPTABILITY AND RESERVES RIGHT
TO REJECT PROPOSED SUBSTITUTION BASED ON INSUFFICIENT INFORMATION; USE ONLY SUBSTITUTIONS
APPROVED IN WRITING. TENANT'S PROJECT MANAGER HAS THE RIGHT TO EMPLOY ARCHITECT TO EVALUATE
AND APPROVE SUBSTITUTIONS.
SECTION 01700 - EXECUTION REQUIREMENTS
A.INSTALLER QUALIFICATIONS: INSTALLERS TO HAVE MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE INSTALLING
ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT, EXCEPT FOR INDIVIDUALS IN TRAINING UNDER DIRECT
SUPERVISION OF EXPERIENCED INSTALLER.
B.EXAMINATION: BEGINNING INSTALLATION OF A PRODUCT SIGNIFIES INSTALLER HAS EXAMINED SUBSTRATES,
AREAS, AND CONDITIONS FOR COMPLIANCE WITH MANUFACTURER REQUIREMENTS FOR TOLERANCES AND OTHER
CONDITIONS AFFECTING PERFORMANCE.
C.MANUFACTURER'S INSTRUCTIONS: WHEN WORK IS SPECIFIED TO COMPLY WITH MANUFACTURERS'
RECOMMENDATIONS OR INSTRUCTIONS, DISTRIBUTE COPIES TO PERSONS INVOLVED, AND MAINTAIN ONE SET IN
FIELD OFFICE.
D.INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS AND INSTALLATION
INSTRUCTIONS UNLESS MORE RESTRICTIVE REQUIREMENTS ARE SPECIFIED.
E.PROTECTION: COVER PRODUCTS SUBJECT TO DETERIORATION WITH IMPERVIOUS SHEET, PROVIDE VENTILATION TO
AVOID CONDENSATION AND TRAPPING WATER.
F.CUTTING AND PATCHING: CUT AND FIT COMPONENTS AS REQUIRED; PATCH DISTURBED AREAS TO MATCH
ADJACENT MATERIALS AND FINISHES.
1.REFINISHING: REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE EVEN FINISH TO MATCH ADJACENT
FINISHES; FOR CONTINUOUS SURFACES REFINISH TO NEAREST INTERSECTION, FOR AN ASSEMBLY REFINISH
ENTIRE UNIT.
G.FINAL CLEANING: CLEAN INTERIOR AND EXTERIOR SURFACES EXPOSED TO VIEW, REMOVE TEMPORARY LABELS,
STAINS, AND FOREIGN SUBSTANCES; POLISH TRANSPARENT AND GLOSSY SURFACES; VACUUM CARPETED AND SOFT
SURFACES; CLEAN DUCTS; CLEAN SITE.
H.SUBSTANTIAL COMPLETION: PROVIDE DOCUMENTATION STATING WORK HAS BEEN SUBSTANTIALLY COMPLETED.
WHERE OWNER REQUIRES USE OF SPACE PRIOR TO FINAL COMPLETION, PROVIDE LIST OF ITEMS TO BE COMPLETED.
1.TENANT'S PROJECT MANAGER WILL REVIEW LIST OF ANY ITEMS TO BE COMPLETED AND SUPPLEMENT LIST
WITH ITEMS CONSIDERED TO BE INCOMPLETE OR UNACCEPTABLE.
I.FINAL COMPLETION: PROVIDE WRITTEN CERTIFICATION INDICATING WORK IS IN COMPLIANCE WITH CONTRACT
DOCUMENTS, SYSTEMS HAVE BEEN TESTED AND ARE OPERATIONAL, AND WORK IS READY FOR FINAL INSPECTION.
J.PROJECT RECORD DOCUMENTS: MAINTAIN COMPLETE AND UP-TO-DATE RECORD DOCUMENTS; KEEP SEPARATE
FROM FIELD DOCUMENTS. SUBMIT PROJECT RECORD DOCUMENTS, MATERIAL AND FINISH DATA, OPERATION AND
INSTRUCTION MANUALS, WARRANTIES AND BONDS AT COMPLETION.
1.SUBMIT BOUND IN 8-1/2" X 11" THREE RING BINDERS WITH DURABLE PLASTIC COVERS. ARRANGE IN FORMAT
SIMILAR TO SPECIFICATIONS.
K.WARRANTIES: PROVIDE WARRANTIES AS INDICATED, SIGNED BY CONTRACTOR AND MANUFACTURER; FORM AS
APPROVED BY TENANT PRIOR TO EXECUTION.
1.WARRANTIES SHALL BE IN ADDITION TO AND NOT A LIMITATION OF OTHER RIGHTS TENANT MAY HAVE
AGAINST CONTRACTOR UNDER CONTRACT DOCUMENTS AND AS PRESCRIBED BY LAW, REGARDLESS OF
WORDING OF WARRANTY.
SECTION 01735 - SELECTIVE DEMOLITION
A.SELECTIVE DEMOLITION: REMOVE FROM SITE EXISTING MATERIALS, CONSTRUCTION AND UTILITIES AS NEEDED TO
COMPLETE PROJECT. REMOVE EXISTING ELEMENTS INDICATED AND ENCOUNTERED DURING CONSTRUCTION, AS
NEEDED TO COMPLETE WORK.
1.REMOVE ONLY THOSE ELEMENTS NECESSARY FOR COMPLETION OF PROJECT, REPLACE OR REPAIR ELEMENTS
UNNECESSARILY REMOVED OR DAMAGED DURING CONSTRUCTION.
2.CAREFULLY REMOVE AND STORE ITEMS INDICATED FOR REUSE IN PROJECT AND COORDINATE WITH OTHER
TRADES FOR MODIFICATIONS AND REINSTALLATION.
3.PROTECTION: PREVENT MOVEMENT AND SETTLEMENT OF ADJACENT STRUCTURE; PROVIDE BRACING,
SHORING, AND UNDERPINNING AS NEEDED AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURES.
ASSUME LIABILITY FOR SUCH MOVEMENT AND SETTLEMENT.
4.UTILITIES: CONTACT APPLICABLE UTILITY COMPANIES PRIOR TO DISCONNECTING UTILITIES; DISCONTINUE
WORK IF UNEXPECTED UTILITY LINES ARE ENCOUNTERED. DETERMINE LINE SOURCE AND USE PRIOR TO
REMOVAL. CAP AND IDENTIFY EXISTING UTILITY LINES REMOVED.
SECTION 01800 - SYSTEMS DEMONSTRATIONS
A.SUMMARY: PROJECT INCLUDES SPECIAL FACILITY START-UP PROCESS TO BRING FACILITY TO FULLY OPERATIONAL
STATE, FREE OF DEFICIENCIES, IN MOST EFFICIENT AND TIMELY MANNER ACHIEVABLE.
DIVISION TWO: SITE CONSTRUCTION (NOT USED)
DIVISION THREE: CONCRETE
SECTION 03300 - CAST IN PLACE CONCRETE
A.GENERAL: PROVIDE CAST IN PLACE CONCRETE FOR SLABS ON GRADE, ALONG WITH ALL REQUIRED ACCESSORIES
AND CONCRETE REINFORCEMENT MATERIALS.
B.INSTALLER QUALIFICATIONS: FIRM WITH A MINIMUM 5 YEARS SUCCESSFUL EXPERIENCE, REGULARLY ENGAGED IN
THE INSTALLATION OF THE SPECIFIED MATERIAL AND PROPERLY EQUIPPED.
C.PERFORM WORK IN ACCORDANCE WITH ACI 301 AND ACI 318. FOLLOW RECOMMENDATIONS OF ACI 305R WHEN
CONCRETING DURING HOT WEATHER, AND ACI 306R WHEN CONCRETING DURING COLD WEATHER.
D.PROJECT RECORD DOCUMENTS: ACCURATELY RECORD ACTUAL LOCATIONS OF EMBEDDED UTILITIES AND
COMPONENTS THAT WILL BE CONCEALED UPON COMPLETION OF CONCRETE WORK.
E.FORM MATERIALS: CONTRACTOR'S CHOICE OF STANDARD PRODUCTS WITH SUFFICIENT STRENGTH TO WITHSTAND
HYDROSTATIC HEAD WITHOUT DISTORTION.
F.REINFORCEMENT MATERIALS AND ACCESSORIES:
1.REINFORCING STEEL: DEFORMED BILLET-STEEL BARS, ASTM A615/A615M GRADE 60.
2.STEEL WELDED REINFORCEMENT: FLAT SHEETS WITH MESH SIZE AND WIRE GAUGE AS NOTED ON DRAWINGS,
ASTM A185/A185M.
3.ACCESSORIES: TIE WIRE (ANNEALED 16 GA. MIN.), CHAIRS, BAR SUPPORTS, SPACERS TO BE SIZED AND SHAPED
FOR ADEQUATE SUPPORT OF REINFORCEMENT DURING CONCRETE PLACEMENT.
G.CONCRETE MATERIALS: CEMENT ASTM C150, TYPE I - NORMAL PORTLAND TYPE. NOMINAL MAX. AGGREGATE SIZE
FOR SLABS IS 34", FLY ASH (ASTM C618) CLASS C OR F, AND CLEAN WATER.
H.ACCESSORY MATERIALS:
1.RETARDING ADMIXTURE: ASTM C494/C494M TYPE B.
2.UNDERSLAB VAPOR RETARDER: MULTI-LAYER REINFORCED POLYETHYLENE COMPLYING WITH ASTM E1745,
CLASS B, WHERE INDICATED ON DRAWINGS.
3.MOISTURE RETAINING COVER: ASTM C171 - REGULAR CURING PAPER.
4.LIQUID CURING COMPOUND: ASTM c309, TYPE 1, CLEAR OR TRANSLUCENT.
I.CONCRETE MIX DESIGN FOR SLABS ON GRADE: COMPRESSIVE STRENGTH OF 4,000 PSI @ 48 HOURS, FLY ASH
CONTENT - 50% MAX., MAX. AGGREGATE SIZE IS 34", SLUMP LIMIT 3-4 INCHES, AIR CONTENT 0%.
J.COORDINATE PLACEMENT OF EMBEDDED ITEMS WITH ERECTION OF CONCRETE FORMWORK, PLACEMENT OF
FORM, REINFORCEMENT ACCESSORIES, AND CONCRETE PLACEMENT.
K.INSTALL REINFORCEMENT WITH NOT LESS THAN MINIMUM COVERAGE REQUIRED FOR PROTECTION, WELDED WIRE
REINFORCEMENT TO BE INSTALLED IN MAX. LENGTHS POSSIBLE WITH OFFSET END LAPS IN BOTH DIRECTIONS AND
TIE WIRED TOGETHER.
L.PLACE CONCRETE FLOOR SLABS IN ACCORDANCE WITH ACI 302.1R, ENSURE REINFORCEMENT, INSERTS, ETC. WILL
NOT BE DISTURBED DURING CONCRETE PLACEMENT. PLACE CONCRETE CONTINUOUSLY BETWEEN PREDETERMINED
EXPANSION, CONTROL AND CONSTRUCTION JOINTS. DO NOT ALLOW COLD JOINTS TO OCCUR. VIBRATE TO
ELIMINATE AIR POCKETS, ETC.
M.SCREED FLOORS AND SLABS ON GRADE LEVEL, MAINTAINING A SURFACE FLATNESS OF MAXIMUM 18 INCH IN 10 FT.
N.FINISH CONCRETE SLAB TO FINISH REQUIREMENT OF ACI 302.1R - STEEL TROWEL SURFACES TO A FLUSH, LEVEL, AND
SMOOTH FINISH AS REQUIRED TO ACCEPT NEW FLOOR FINISHES SPECIFIED.
O.CURING AND PROTECTION: COMPLY WITH REQUIREMENTS OF ACI 308. IMMEDIATELY AFTER PLACEMENT,
PROTECT CONCRETE FROM PREMATURE DURING, EXCESSIVE TEMPERATURES, AND MECHANICAL INJURY.
SECTION 03540 - CEMENTITIOUS UNDERLAYMENT
A.GENERAL: PROVIDE POURED CEMENTITIOUS UNDERLAYMENT SYSTEM, NOT INTENDED AS FINISHED TRAFFIC
SURFACE, INCLUDING ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
B.INSTALLER: FIRM WITH MINIMUM 5 YEARS SUCCESSFUL EXPERIENCE, REGULARLY ENGAGED IN INSTALLATION OF
SPECIFIED MATERIALS, PROPERLY EQUIPPED AND ACCEPTABLE TO MANUFACTURER.
C.SUBMITTALS: FURNISH MANUFACTURER'S LITERATURE.
D.MANUFACTURER: ARDEX, INC./K-15; W.R.BONSAL CO./SELF-LEVELING WEAR TOPPING.
E.SYSTEM: POURABLE CEMENTITIOUS, HIGH-STRENGTH, FAST-SETTING, NON-SHRINK, SELF-LEVELING
UNDERLAYMENT; MINIMUM 4000 PSI COMPRESSIVE STRENGTH AT 28 DAYS, ASTM C349.
F.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS.
DIVISION FOUR: MASONRY (NOT USED)
DIVISION FIVE: METALS
SECTION 05500 - METAL FABRICATIONS
A.GENERAL: PROVIDE MISCELLANEOUS METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS
PART OF OTHER SECTIONS, WITH ANCHORS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
B.SUBMITTALS: FURNISH SHOP DRAWINGS FOR CUSTOM FABRICATIONS, PRODUCT DATA FOR MANUFACTURED
ITEMS; PROVIDE TEMPLATES FOR ANCHOR INSTALLATION BY OTHERS.
C.STEEL SHAPES: ASTM A36 STEEL.
D.GROUT: PROVIDE NON-SHRINK, NON-METALLIC, PRE-MIXED, FACTORY PACKAGED, NON-STAINING,
NON-CORROSIVE, NON-GASEOUS GROUT; TYPE SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR
APPLICATIONS INDICATED.
E.FASTENERS AND ROUGH HARDWARE: TYPE REQUIRED FOR SPECIFIC USAGE; PROVIDE ZINC-COATED FASTENERS FOR
EXTERIOR USE OR WHERE BUILT INTO EXTERIOR WALLS.
F.WELDING MATERIALS: AWS D1.1, TYPE REQUIRED FOR MATERIALS BEING WELDED.
G.PAINT: PROVIDE PRIMERS AS RECOMMENDED BY PAINT MANUFACTURERS FOR SUBSTRATES AND PAINTS SPECIFIED
IN SECTION 09900 - PAINTING.
1.GALVANIZING REPAIR PAINT: HIGH ZINC-DUST CONTENT PAINT FOR REGALVANIZING WELDS IN GALVANIZED
STEEL.
H.FABRICATION: FABRICATE ITEMS WITH JOINTS NEATLY FITTED AND PROPERLY SECURED; GRIND EXPOSED WELDS
CONTINUOUS, SMOOTH AND FLUSH WITH ADJACENT FINISHED SURFACES, AND EASE EXPOSED EDGES TO
APPROXIMATE 1/32" UNIFORM RADIUS.
1.MAKE EXPOSED JOINTS FLUSH BUTT TYPE, HAIRLINE JOINTS WHERE MECHANICALLY FASTENED.
2.FIT AND SHOP ASSEMBLE IN LARGEST PRACTICAL SECTIONS FOR DELIVERY.
I.FINISHES: GALVANIZE AND PRIME PAINT EXTERIOR MISCELLANEOUS METAL, PRIME PAINT INTERIOR
MISCELLANEOUS METAL; GALVANIZE COATING MINIMUM G90 COATING, GALVANIZED AFTER FABRICATION.
1.CLEAN SURFACES OF RUST, SCALE, GREASE AND FOREIGN MATTER PRIOR TO APPLYING GALVANIZED OR
PAINTED FINISH.
J.INSTALLATION: INSTALL ITEMS SQUARE AND LEVEL, ACCURATELY FITTED AND FREE FROM DISTORTION OR DEFECTS
DETRIMENTAL TO APPEARANCE OR PERFORMANCE; ENSURE ALIGNMENT WITH ADJACENT CONSTRUCTION;
COORDINATE WITH RELATED WORK TO ENSURE NO INTERRUPTION IN INSTALLATION.
1.SUPPLY ITEMS REQUIRING TO BE CAST INTO OR EMBEDDED IN OTHER MATERIALS TO APPROPRIATE TRADES.
2.AFTER INSTALLATION, TOUCH-UP FIELD WELDS AND SCRATCHED AND DAMAGED SURFACES; USE PRIMER
CONSISTENT WITH SHOP COAT OR RECOMMENDED FOR GALVANIZED SURFACES, AS APPLICABLE.
SECTION 05700 - ORNAMENTAL METALS
A.GENERAL: PROVIDE CUSTOM ORNAMENTAL METAL ITEMS AS INDICATED WITH ACCESSORIES AND ATTACHMENT
DEVICES AS REQUIRED FOR COMPLETE, FINISHED INSTALLATION.
B.ORNAMENTAL METAL ITEMS:
1.PROVIDE BREAK METAL SHAPES AS INDICATED ON DRAWINGS.
C.SUBMITTALS: FURNISH PRODUCT DATA, SHOP DRAWINGS, AND SAMPLES OF EACH EXPOSED METAL FINISH.
D.FABRICATOR: FIRM WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE FABRICATING ORNAMENTAL METAL
ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT.
E.STAINLESS STEEL: ASTM A666, TYPE 302/304 CORROSION RESISTANT STAINLESS STEEL WITH NO. 4 SATIN
DIRECTIONAL FINISH.
F.ALUMINUM: MINIMUM ASTM B209, 6061-T6 PLATE AND SHEET, ASTM B221, 6063-T6 EXTRUSIONS; SIZED FOR
STRENGTH AND DURABILITY CONSISTENT WITH APPLICATION INVOLVED.
1.FINISH: PROVIDE FACTORY FORMULATED POLYESTER TGIC POWDER COATING MATERIALS INTENDED FOR
POWDER COATING APPLICATION CUSTOM COLOR AS DIRECTED BY ARCHITECT.
G.BRACKETS AND ANCHORS: UNEXPOSED PLATES, ANGLES AND SUPPORTS MAY BE STEEL; EXPOSED ITEMS TO MATCH
ORNAMENTAL METAL TYPE AND FINISH.
H.FASTENERS: TYPE REQUIRED FOR SPECIFIC USAGE; PROVIDE CONCEALED FASTENERS EXCEPT WHERE SPECIFICALLY
APPROVED; WHERE EXPOSED MATCH TYPE AND FINISH OF METAL BEING FASTENED.
1.CONCEALED STEEL FASTENERS: HOT-DIPPED GALVANIZED MINIMUM G90 WHERE BUILT INTO EXTERIOR WALLS
OR SUBJECT TO HIGH HUMIDITY.
I.FABRICATION: FABRICATE COMPONENT CONNECTIONS TO SUPPORT SPECIFIED DESIGN LOADS.
1.SELECT MATERIALS FOR STRAIGHTNESS, FREE OF DEFECTS AND IRREGULARITIES.
2.EXPOSED-TO-VIEW SURFACES EXHIBITING PITTING, SEAM MARKS, ROLLER MARKS, "OIL CANNING," STAINS,
DISCOLORATIONS, AND IMPERFECTIONS ON FINISHED UNITS ARE NOT ACCEPTABLE.
3.MAKE EXPOSED JOINTS FLUSH BUTT TYPE, HAIRLINE JOINTS WHERE MECHANICALLY FASTENED; PROVIDE
CONCEALED CONNECTION DEVICES WITH HIDDEN FASTENERS.
4.SEPARATE DISSIMILAR MATERIALS WITH BITUMINOUS PAINT WHERE CONCEALED, WITH PREFORMED
SEPARATORS, OR SIMILAR METHOD TO PREVENT CORROSION.
J.INSTALLATION: INSTALL ORNAMENTAL METAL ITEMS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS, INSTALLATION INSTRUCTIONS, AND APPROVED SHOP DRAWINGS.
1.INSTALL PLUMB, TRUE AND IN CORRECT RELATION TO ADJACENT WORK, FREE FROM DISTORTION OR DEFECTS
DETRIMENTAL TO APPEARANCE AND PERFORMANCE.
2.PRIOR TO SECURING CONTINUOUS ITEMS, ADJUST TO ENSURE PROPER MATCHING AT BUTT JOINTS AND
CORRECT ALIGNMENT THROUGHOUT THEIR LENGTH.
3.REPAIR OR REPLACE ITEMS DAMAGED OR MARRED DURING CONSTRUCTION.
DIVISION SIX: WOOD AND PLASTICS
SECTION 06105 - MISCELLANEOUS ROUGH CARPENTRY
A.GENERAL: PROVIDE MISCELLANEOUS BLOCKING AND PLYWOOD.
B.STANDARDS: COMPLY WITH REQUIREMENTS OF AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC),
AMERICAN PLYWOOD ASSOCIATION (APA), AND APPLICABLE CODE REQUIREMENTS.
C.BLOCKING: COMPLY WITH PS 20; GRADED BY AN AGENCY CERTIFIED BY NATIONAL FOREST PRODUCTS ASSOCIATION
(NFPA) AND OF TYPE RECOMMENDED FOR APPLICATION INVOLVED; DOUGLAS FIR OR SOUTHERN PINE; MINIMUM
CONSTRUCTION GRADE S-DRY.
D.PLYWOOD: PROVIDE MINIMUM APA C-D EXTERIOR (CDX) PLYWOOD; STRESS RATED WHERE SPANNING SUPPORTING
MEMBERS; FIRE RETARDANT TREATED; MINIMUM 3/4" THICK UNLESS OTHERWISE INDICATED.
1.PLYWOOD STANDARD: COMPLY WITH PS1 (ANSI A199.1).
2.PLYWOOD PANEL BOARDS: PROVIDE PANEL BOARDS FOR ELECTRICAL AND COMMUNICATION PANEL BOARDS;
APA C-D PLUGGED, INTERIOR TYPE PLYWOOD WITH EXTERIOR GLUE, FIRE RETARDANT TREATED; MINIMUM
1/2" THICK.
E.TREATED WOOD: PRESSURE TREAT WOOD IN CONTACT WITH CONCRETE AND WITH ROOFING; FIRE TREAT WOOD
CONCEALED IN INTERIOR; FIRE TREAT BLOCKING AT ROOFING WHERE REQUIRED BY APPLICABLE AUTHORITIES.
1.PRESSURE TREATED: WATER-BORNE PRESERVATIVES FOR ABOVE GROUND USE CONFORMING TO AWPA C2
AND C9.
2.FIRE TREATED: CONFORM TO AWPA C20 AND C27, INTERIOR TYPE A AT INTERIOR APPLICATIONS; PASS ASTM
D2898 RAIN TEST WHERE AT EXTERIOR WALLS AND ROOF; IDENTIFY WITH FRTW.
3.KILN-DRY TREATED WOOD TO 19 % MOISTURE CONTENT AND DISCARD WARPED AND DAMAGED PIECES.
F.FASTENERS: PROVIDE FASTENERS AS REQUIRED FOR COMPLETE, SECURE INSTALLATION OF MISCELLANEOUS ROUGH
CARPENTRY; GALVANIZED AT EXTERIOR LOCATIONS AND PRESSURE TREATED WOOD; SIZE AND TYPE TO SUIT
APPLICATION; PROVIDE WASHERS FOR NUTS AND BOLTS.
G.INSTALLATION: COMPLY WITH REFERENCED STANDARDS AND APPLICABLE CODE REQUIREMENTS.
1.PLYWOOD: COMPLY WITH RECOMMENDATIONS OF AMERICAN PLYWOOD ASSOCIATION (APA) FOR
FABRICATION AND INSTALLATION OF PLYWOOD WORK.
2.PLACE MISCELLANEOUS ROUGH CARPENTRY TRUE TO LINES AND LEVELS.
3.CORRELATE LOCATION SO ATTACHED WORK WILL COMPLY WITH DESIGN REQUIREMENTS AND BE PROPERLY
LOCATED.
4.CONSTRUCT MEMBERS OF CONTINUOUS PIECES OF LONGEST POSSIBLE LENGTHS.
5.FIT CARPENTRY WORK TO OTHER WORK; SCRIBE AND COPE AS REQUIRED FOR ACCURATE FIT.
6.SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES BY ANCHORING AND FASTENING AS REQUIRED BY
RECOGNIZED STANDARDS.
7.PROVIDE WASHERS UNDER BOLT HEADS AND NUTS IN CONTACT WITH WOOD.
SECTION 06200 - FINISH CARPENTRY
A.GENERAL: PROVIDE WOOD TRIM, WOOD SHELVING, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED
INSTALLATION.
B.STANDARDS: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWI)/QUALITY STANDARDS "MANUAL OF
MILLWORK" STANDARDS; MINIMUM WIC/CUSTOM GRADE.
C.SUBMITTALS: FURNISH PRODUCT DATA FOR MANUFACTURED ITEMS, SHOP DRAWINGS FOR CUSTOM ITEMS,
SAMPLES OF EACH EXPOSED FINISH.
D.CERTIFICATION: CERTIFICATION WILL NOT BE REQUIRED.
E.MANUFACTURER: TO BE DETERMINED
F.DELIVERY, STORAGE AND HANDLING: COMPLY WITH AWI STANDARDS AND MANUFACTURER RECOMMENDATIONS.
G.WOOD TRIM: PREMIUM GRADE FOR OPAQUE PAINT FINISH; WHITE BIRCH OR POPLAR UNLESS OTHERWISE
INDICATED.
H.WOOD SHELVING: AWI OR WIC/CUSTOM GRADE, PARTICLE BOARD, OR HARDWOOD-EDGED PLYWOOD.
I.ANCHORS, NAILS AND SCREWS: SELECT THE MATERIAL, TYPE, SIZE AND FINISH REQUIRED BY EACH SUBSTRATE FOR
SECURE ANCHORAGE; PROVIDE TOOTHED STEEL OR LEAD EXPANSION BOLT SCREWS FOR DRILLED-IN-PLACE
ANCHORS.
J.WOOD FILLER: COLOR TO MATCH WOOD BEING FILLED.
K.FABRICATION: FABRICATE FINISH CARPENTRY ITEMS IN ACCORDANCE WITH SPECIFIED QUALITY STANDARD.
L.INSTALLATION: INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT
WITH NO DISTORTIONS; SHIM AS REQUIRED, USING CONCEALED SHIMS.
M.PREPARATION FOR FIELD FINISHING: SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS; APPLY WOOD
FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS AND LEAVE READY TO RECEIVE SITE-APPLIED FINISHES.
1.SEAL CONCEALED AND SEMI-CONCEALED SURFACES; BRUSH APPLY ONLY, USING PRIMER CONSISTENT WITH
FINISH COATS SPECIFIED UNDER SECTION 09900 - PAINTS AND COATINGS.
SECTION 06400 - ARCHITECTURAL WOODWORK
A.INSTALL TENANT FURNISHED CASEWORK AND COUNTERTOPS INDICATED TO BE TENANT FURNISHED AND PROVIDE
ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
B.STANDARDS: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWI)/QUALITY STANDARDS "MANUAL OF
MILLWORK" STANDARDS; MINIMUM PREMIUM GRADE.
C.SUBMITTALS: FURNISH PRODUCT DATA FOR CONTRACTOR FURNISHED ACCESSORIES INCLUDING SAMPLES OF
EXPOSED MATERIALS.
D.STORAGE AND HANDLING: COMPLY WITH MANUFACTURER RECOMMENDATIONS.
E.ACCESSORIES: PROVIDE AS INDICATED AND AS REQUIRED TO INSTALL ARCHITECTURAL WOODWORK AS INDICATED;
COORDINATE ACCESSORIES REQUIRED FOR INSTALLATION OF OWNER FURNISHED ARCHITECTURAL WOODWORK
NOT FURNISHED WITH ARCHITECTURAL WOODWORK.
F.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND REFERENCED STANDARDS. TAKE SPECIAL
CARE COORDINATING INSTALLATION OF OWNER FURNISHED ARCHITECTURAL WOODWORK WITH MANUFACTURER
RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS.
1.INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO
DISTORTIONS.
2.SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK.
3.ENSURE MECHANICAL AND ELECTRICAL ITEMS AFFECTING ARCHITECTURAL WOODWORK ARE PROPERLY
PLACED, COMPLETE, AND HAVE BEEN INSPECTED TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION OF
WOODWORK. SECURE WORK TO GROUNDS, STRIPPING AND BLOCKING WITH COUNTERSUNK, CONCEALED
FASTENERS AND BLIND NAILING AS REQUIRED FOR A COMPLETE INSTALLATION.
4.SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK.
5.ATTACH ARCHITECTURAL WOODWORK SECURELY IN PLACE WITH UNIFORM JOINTS PROVIDING FOR THERMAL
AND BUILDING MOVEMENTS.
6.ACCEPTABLE TOLERANCES:
A. VARIATION FROM TRUE POSITION: MAXIMUM 1/16" AT ANY POSITION AND MAXIMUM 1/8" IN ANY
10'-0" LENGTH.
B. ADJOINING SURFACES OF SAME MATERIAL: NO VARIATION PERMITTED.
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
SPECIFICATIONS
SP.1
DIVISION SEVEN: THERMAL AND MOISTURE PROTECTION
SECTION 07210 - INSULATION
A.GENERAL: PROVIDE THERMAL INSULATION WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
1.INSULATION INTEGRAL WITH ROOFING REPAIRS IS PROVIDED WITH ROOFING, AND ACOUSTICAL INSULATION IS
PROVIDED WITH GYPSUM BOARD ASSEMBLIES.
B.THERMAL BATT INSULATION: OWENS CORNING/FS-25, USG/THERMAFIBER FS25, OR JOHNS MANVILLE/FSK-25; FOIL
FACED VAPOR RETARDER FACED, VAPOR RETARDER TOWARD INSIDE.
1.THICKNESS/R-VALUE: AS INDICATED ON DRAWINGS.
C.ACCESSORIES: PROVIDE TAPE OR PENETRATION ANCHORS WHERE REQUIRED TO ENSURE PERMANENT
INSTALLATION.
D.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS.
SECTION 07560 - ROOF REPAIRS
A.GENERAL: REPAIR EXISTING ROOFING SYSTEM AS REQUIRED FOR NEW CONSTRUCTION, WITH COMPONENTS AND
ACCESSORIES AS REQUIRED FOR COMPLETE WEATHERTIGHT INSTALLATION. G.C. TO USE LANDLORD'S ROOFING
CONTRACTOR.
B.STANDARDS: CONFORM TO NATIONAL ROOFING CONTRACTOR'S ASSOCIATION ROOFING AND WATERPROOFING
MANUAL, 4TH OR 5TH EDITION.
C.WARRANTY: PROVIDE FOR CORRECTING FAILURE OF ROOF REPAIRS TO RESIST PENETRATION OF WATER AND
DAMAGE FROM WIND; WARRANTY PERIOD OF TWO YEARS.
D.ROOFING SYSTEM: MATCH EXISTING ROOFING, NO SUBSTITUTIONS PERMITTED; PROVIDE MATERIALS CAPABLE OF
MAINTAINING EXISTING WARRANTIES; CONFORM TO REQUIREMENTS OF NRCA ROOFING MANUAL.
1.SYSTEM: PROVIDE COMPLETE SYSTEM WITH ACCESSORIES AS REQUIRED FOR REPAIRS, INCLUDING INSULATION
WHERE EXISTING ROOFING IS INSULATED.
E.ROOF SYSTEM REPAIRS: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS AND NRCA
RECOMMENDATIONS FOR ROOF TYPE SPECIFIED.
1.REMOVE EXISTING ROOFING AS REQUIRED FOR PROJECT; REMOVE ONLY AS MUCH ROOFING AS CAN BE
REPLACED IN SAME DAY UNLESS OTHERWISE APPROVED IN ADVANCE BY ARCHITECT.
2.INSPECT SUBSTRATES AND ROOF DECK TO ENSURE SUBSTRATES AND DECK ARE CLEAN AND SMOOTH, FREE OF
DEPRESSIONS, WAVES OR PROJECTIONS, AND ARE PROPERLY SLOPED TO DRAINS, VALLEY, OR EAVES.
3.INSULATION APPLICATION: ATTACH INSULATION IN ACCORDANCE WITH INSULATION MANUFACTURER'S
INSTRUCTIONS AND NRCA RECOMMENDATIONS FOR INSTALLATION OF INSULATION ON DECK INVOLVED.
4.COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF COMPOSITION TYPE BASE,
WALL AND FIELD FLASHINGS.
5.COORDINATE METAL FLASHINGS AND COUNTERFLASHING.
6.COORDINATE INSTALLATION OF ROOF DRAINS AND RELATED FLASHINGS.
7.MOP IN AND SEAL FLASHINGS AND FLANGES OF ITEMS PROJECTING THROUGH MEMBRANE.
F.MAINTAIN ANY EXISTING ROOFING SYSTEM WARRANTIES.
SECTION 07600 - FLASHING AND SHEET METAL
A.GENERAL: PROVIDE FLASHING AND SHEET METAL, REGLETS, AND ACCESSORIES AS REQUIRED FOR ROOF REPAIRS AS
REQUIRED FOR COMPLETE, WEATHERTIGHT INSTALLATION.
B.STANDARDS: CONFORM TO SMACNA "ARCHITECTURAL SHEET METAL MANUAL" REQUIREMENTS FOR FLASHING
AND SHEET METAL.
C.DESIGN REQUIREMENTS: ALLOW FOR MOVEMENT OF COMPONENTS WITHOUT CAUSING BUCKLING, FAILURE OF
JOINT SEALS, UNDUE STRESS ON FASTENERS OR OTHER DETRIMENTAL EFFECTS, WHEN SUBJECT TO 100 YEAR
SEASONAL TEMPERATURE RANGES.
D.SUBMITTALS: FURNISH PRODUCT DATA FOR MANUFACTURED PRODUCTS.
E.WARRANTY: CORRECT FAILURE OF METAL FLASHING SYSTEM TO RESIST PENETRATION OF WATER AND DAMAGE
FROM WIND; WARRANTY PERIOD TWO YEARS.
F.FLASHING AND SHEET METAL: MATCH EXISTING, BUT NOT LESS THAN FOLLOWING:
1.GALVANIZED METAL FLASHING: ASTM A653/A653M GALVANIZED STEEL WITH MINIMUM 0.02 COPPER, AND
WITH MINIMUM G90/Z275 GALVANIZED COATING; MINIMUM 24 GAGE.
2.PREFINISHED METAL FLASHING: 24 GAGE GALVANIZED STEEL WITH FACTORY FINISHED KYNAR 500 TYPE
FLUOROPOLYMER COATING AND STRIPPABLE PROTECTIVE FILM; COLOR AS SELECTED FROM MANUFACTURER'S
FULL RANGE OF COLORS.
3.ALUMINUM FLASHING: ASTM B209, ALLOY AS REQUIRED TO MATCH FINISH SPECIFIED FOR OTHER ALUMINUM
COMPONENTS; THICKNESS MINIMUM 0.050" AT FLASHINGS.
4.STAINLESS STEEL SHEET METAL: ASTM A666, 2D ANNEALED FINISH, SOFT TEMPER EXCEPT WHERE HARDER
TEMPER IS REQUIRED FOR FORMING OR PERFORMANCE; 0.015" (28 GAGE) TYPICAL.
5.COPPER SHEET METAL: ASTM B370, COLD ROLLED 16 OZ. (0.0216") THICK; SOFT TEMPER WHERE REQUIRED FOR
FORMING.
G.REGLETS: FRY/SPRINGLOK OR MM SYSTEMS/SNAP-TITE REGLETS; FABRICATE OF SAME METAL AS ADJACENT
FLASHING AND SHEET METAL.
H.METAL TO METAL SEALANT: BUTYL TYPE; NON-STAINING, NON-CORROSIVE, NON-SHRINKING, NON-SAGGING,
ULTRA-VIOLET AND OZONE RESISTANT.
I.INSTALLATION: COMPLY WITH SMACNA MANUAL.
1.INSTALL METAL FLASHING AND SHEET METAL IN ACCORDANCE WITH SMACNA ARCHITECTURAL SHEET METAL
MANUAL; TIGHT IN PLACE, WITH CORNERS SQUARE, SURFACES TRUE AND STRAIGHT IN PLANES, AND LINES
ACCURATE TO PROFILES AS INDICATED ON DRAWINGS.
2.INSTALL SEALANTS WHERE REQUIRED TO PREVENT DIRECT WEATHER PENETRATION.
3.COMPLETED INSTALLATION SHALL BE FREE OF RATTLES, NOISE DUE TO THERMAL AND AIR MOVEMENT, AND
WIND WHISTLES.
SECTION 07810 - PATCHING EXISTING FIREPROOFING
A.GENERAL: PATCH EXISTING FIREPROOFING AS REQUIRED BY APPLICABLE CODES FOR CONSTRUCTION TYPE; NO
ASBESTOS PERMITTED.
B.DESIGN REQUIREMENTS: PROVIDE MATERIALS CAPABLE OF ATTAINING FIRE RATINGS AS REQUIRED FOR
CONSTRUCTION TYPE.
C.PERFORMANCE REQUIREMENTS: PROVIDE MATERIALS LISTED BY U.L. OR INDEPENDENT TESTING AND INSPECTION
AGENCY ACCEPTABLE TO APPLICABLE AUTHORITIES.
1.FIRE RESISTANCE RATINGS: COMPLY WITH REQUIRED RATINGS BASED ON TESTS IN ACCORDANCE WITH ASTM
E119.
2.SURFACE BURNING CHARACTERISTICS: MAXIMUM 25 FLAME SPREAD AND 25 SMOKE DENSITY WHEN TESTED IN
ACCORDANCE WITH ASTM E84.
D.CERTIFICATE: SUBMIT MANUFACTURER CERTIFICATION INDICATING APPLICATOR ACCEPTABILITY AND MATERIAL
COMPLIANCE WITH APPLICABLE CODES AND CONTRACT DOCUMENTS.
1.CERTIFICATION SHALL INDICATE NEW MATERIALS USED TO PATCH EXISTING FIREPROOFED MEMBERS AT NEW
AND EXISTING WORK ARE COMPATIBLE WITH EXISTING FIREPROOFING MATERIALS AND MEET ALL
PERFORMANCE REQUIREMENTS.
E.QUALIFICATION OF APPLICATOR: FIRM ACCEPTABLE TO MANUFACTURER OF FIREPROOFING MATERIALS, WITH
MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE ON PROJECTS OF SIMILAR SCOPE.
F.MANUFACTURERS/PRODUCTS: MATCH EXISTING BUT NOT LESS THAN W.R. GRACE/MONOKOTE OR EQUAL.
G.INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS AS
REQUIRED TO PROVIDE REQUIRED FIRE RATINGS.
1.PROTECT ADJACENT SURFACES AND EQUIPMENT FROM DAMAGE BY OVERSPRAY, FALLOUT, AND DUSTING;
MASK ADJACENT WORK AS REQUIRED. CLOSE OFF AND SEAL DUCT WORK IN AREAS WHERE FIREPROOFING IS
BEING APPLIED.
2.CLEAN SUBSTRATE OF DIRT, DUST, GREASE, OIL, LOOSE MATERIAL, PAINTS, PRIMERS, AND OTHER MATTER
WHICH AFFECTS BOND OF SPRAYED FIREPROOFING.
3.APPLY FIREPROOFING IN SUFFICIENT THICKNESS AND DENSITY TO ACHIEVE REQUIRED FIRE RATINGS.
4.APPLY FIREPROOFING OVER SUBSTRATE, BUILDING TO REQUIRED THICKNESS WITH AS MANY PASSES OR
STAGES NECESSARY TO COVER WITH MONOLITHIC BLANKET OF UNIFORM DENSITY AND TEXTURE.
SECTION 07840 - FIRESTOPPING
A.GENERAL: PROVIDE PENETRATION-TYPE FIRESTOPPING FOR TIME-RATED FLOOR, WALL, AND PARTITION ASSEMBLIES
CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE AND HOT GASES.
B.CODES: CONFORM TO APPLICABLE CODE REQUIREMENTS FOR BOTH F AND T RATINGS.
C.STANDARDS: PASS ASTM E814 THROUGH-PENETRATION FIRE STOPS, ASTM E119 FIRE TESTS AND ASTM E84 FLAME
SPREAD/SMOKE CONTRIBUTION MAXIMUM 25/25.
D.MANUFACTURERS: 3M/FIRE BARRIER, HILTI/FIRESTOP SYSTEMS, OR APPROVED EQUAL.
E.GENERAL: CHOOSE PRODUCTS AND METHODS MEETING APPLICABLE CODES AND SPECIFICATION REQUIREMENTS
FOR EACH FIRESTOPPING APPLICATION, SUBJECT TO ARCHITECT'S ACCEPTANCE.
F.FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR, WALL, AND PARTITION
ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES.
1.PENETRATION TEST: FURNISH MATERIALS PASSING ASTM E814 FOR PENETRATION FIRE STOPPING INDICATING
MAINTENANCE OF TIME-RATED ADJACENT ASSEMBLIES.
2.FIRESTOPPING: MAINTAIN FIRE RATING OF ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED, SUCH AS FLOOR,
PARTITION, OR WALL, IN ACCORDANCE WITH ASTM E119 TESTS.
G.INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS AS
REQUIRED TO PROVIDE REQUIRED FIRE RATINGS.
1.FIELD INSPECTIONS: MAINTAIN COPY OF MANUFACTURER'S INSTALLATION INSTRUCTIONS AND
RECOMMENDATIONS AT EACH WORK AREA.
SECTION 07900 - JOINT SEALERS
A.GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDED ELSEWHERE; TYPE SUITABLE FOR
APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION.
B.INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM FIVE YEAR'S SUCCESSFUL EXPERIENCE ON PROJECTS OF SIMILAR
TYPE AND SIZE, USING SPECIFIED PRODUCTS.
C.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EXPOSED JOINT SEALERS IN REQUIRED COLORS.
D.WARRANTY: REPAIR OR REPLACE JOINT SEALERS WHICH FAIL TO PERFORM AS INTENDED, BECAUSE OF LEAKING,
CRUMBLING, HARDENING, SHRINKAGE, BLEEDING, SAGGING, STAINING AND LOSS OF ADHESION; WARRANTY
PERIOD TWO YEARS.
E.EXTERIOR NON-TRAFFIC JOINTS: GE/SILPRUF, DOW/790-795, OR PECORA/854, LOW MODULUS SILICONE SEALANT.
F.TRAFFIC BEARING JOINTS: MAMECO/VULKEM 245, OR PECORA/NR-200 UREXPAN, MULTI-COMPONENT
POLYURETHANE, SELF-LEVELING JOINT SEALER.
G.MILDEW-RESISTANT SANITARY SEALANTS: GE/SANITARY SEALANT, DOW/BATHTUB CAULK, OR PECORA/863 #345
WHITE; PROVIDE AT INTERIOR AREAS WHERE SEALANT WILL BE EXPOSED TO WATER.
H.GENERAL INTERIOR JOINT SEALER: PECORA/AC-20 OR SONNEBORN/SONOLAC, ACRYLIC OR LATEX EMULSION.
I.MISCELLANEOUS MATERIALS: PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE, AND SEALANT BACKER
RODS AS RECOMMENDED BY SEALANT MANUFACTURER FOR APPLICATIONS INDICATED.
1.OVERSIZE BACKER ROD MINIMUM 30 % TO 50 % OF JOINT OPENING.
J.COLORS: AS INDICATED OR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE OF COLORS.
K.PREPARATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT SEALER, AND PRIME OR SEAL
JOINT SURFACES AS RECOMMENDED BY MANUFACTURER.
L.INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND ASTM C1193.
1.EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE DEPOSITED IN UNIFORM,
CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS, WITH COMPLETE "WETTING" OF BOND SURFACES.
DIVISION EIGHT: DOOR AND WINDOWS
SECTION 08110 - STEEL DOORS AND FRAMES
A.GENERAL: PROVIDE STEEL DOORS AND FRAMES AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION;
COORDINATE WITH SECTION 08700 - HARDWARE.
B.STANDARDS: COMPLY WITH NAAMM HMMA 840 'GUIDE SPECIFICATIONS FOR INSTALLATION AND STORAGE OF
HOLLOW METAL DOORS' AND ANSI A250.8 - SDI-100 'RECOMMENDED SPECIFICATIONS FOR STANDARD STEEL
DOORS AND FRAMES'.
1.FIRE RATED STANDARDS: FURNISH MATERIALS TESTED, LABELED AND INSPECTED BY U.L., WARNOCK HERSEY,
OR TESTING AGENCY ACCEPTABLE TO APPLICABLE AUTHORITIES.
C.SUBMITTALS: SUBMIT PRODUCT DATA.
D.MANUFACTURERS: AMWELD, CECO, OR STEELCRAFT.
E.HOLLOW METAL DOORS: FLUSH HOLLOW METAL DOORS FULL FLUSH TYPE; ANSI A250.8, LEVEL A, CLOSE TOP AT
EXTERIOR DOORS.
1.CORE: PROVIDE STEEL STIFFENED CORE; INSULATED AT EXTERIOR DOORS.
2.GAGE: PROVIDE MINIMUM 18 GAGE AT INTERIOR DOORS, MINIMUM 16 GAGE AT EXTERIOR DOORS.
F.STEEL (HOLLOW METAL) FRAMES: MINIMUM 18 GAGE FULLY WELDED FRAMES AT INTERIOR DOORS, MINIMUM 16
GAGE FULLY WELDED FRAMES AT EXTERIOR DOORS.
G.FIRE RATED UNITS: CONFORM TO NFPA 80; PROVIDE U.L. OR WARNOCK HERSEY LABELED DOORS AND FRAMES AS
REQUIRED.
H.ACCESSORIES: PROVIDE DOOR SILENCERS, ANCHORS, AND ACCESSORIES.
I.FABRICATION: CONFORM TO REQUIREMENTS OF NAAMM HMMA 840.
1.DOOR SILENCERS: PLACE MINIMUM THREE SINGLE BUMPERS ON SINGLE DOOR FRAMES; SPACE EQUALLY
ALONG STRIKE JAMBS; PLACE TWO SINGLE BUMPERS ON DOUBLE DOOR FRAME HEADS.
J.FINISH: PRIME PAINT INTERIOR UNITS, GALVANIZE AND PRIME PAINT EXTERIOR UNITS; MINIMUM A60
GALVANIZING; CLEAN, DEGREASE AND FACTORY PRIME PAINT.
K.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND NAAMM HMMA 840 STANDARDS.
1.INSTALL FIRE RATED UNITS IN CONFORMANCE WITH FIRE LABEL REQUIREMENTS & NFPA80.
2.INSTALL DOORS AND FRAMES PLUMB AND SQUARE, AND WITH MAXIMUM DIAGONAL DISTORTION OF 1/16".
SECTION 08200 - WOOD DOORS AND FRAMES
A.GENERAL: PROVIDE WOOD DOORS AND FRAMES AND ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION.
COORDINATE WITH SECTION 08110 (STEEL DOORS AND FRAMES), SECTION 08120 (ALUMINUM DOORS AND
FRAMES), AND SECTION 08700 (HARDWARE).
B.STANDARDS: COMPLY WITH AWI/AWMAC (QSI) 'ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED'.
C.SUBMITTALS: SUBMIT PRODUCT DATA, SHOP DRAWINGS, AND FINISH SAMPLES.
D.MANUFACTURER'S QUALIFICATIONS: COMPANY SPECIALIZING IN THE MANUFACTURE OF THE PRODUCTS SPECIFIED
IN THIS SECTION WITH A MINIMUM FIVE YEARS EXPERIENCE.
E.PACKAGE, DELIVER AND STORE DOORS IN ACCORDANCE WITH SPECIFIED QUALITY STANDARD. INSPECT FOR
DAMAGE.
F.MANUFACTURERS: GRAHAM WOOD DOORS, EGGERS INDUSTRIES, MARSHFIELD DOOR SYSTEMS OR APPROVED
EQUAL.
G.PREMIUM GRADE HEAVY DUTY PERFORMANCE IN ACCORDANCE WITH AWI/AWMAC STANDARDS, 5 PLY WOOD
VENEER FACED SOLID CORE DOORS, 1 34 INCH THICK, FLUSH CONSTRUCTION.
1.WOOD VENEER SPECIES AND CUT AS INDICATED ON DRAWINGS.
2.FACTORY PREFINISHED WITH A CUSTOM COLOR TRANSPARENT FINISH.
H.FABRICATE DOORS IN ACCORDANCE WITH DOOR QUALITY STANDARD NOTED. CORES CONSTRUCTED WITH STILES
AND RAILS, PROVIDE SOLID BLOCKS AT LOCK/HARDWARE EDGE AND AT TOP AND BOTTOM OF DOORS. FACTORY
MACHINE DOORS FOR HARDWARE OTHER THAN SURFACE MOUNTED HARDWARE.
I.FACTORY FIT DOORS FOR FRAME OPENING DIMENSIONS IDENTIFIED ON SHOP DRAWINGS, WITH EDGE CLEARANCES
IN ACCORDANCE WITH SPECIFIED QUALITY STANDARD.
J.INSTALL DOORS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND SPECIFIED QUALITY STANDARD. DO
NOT INSTALL DOORS IN FRAME OPENINGS THAT ARE NOT PLUMB OR ARE OUT OF TOLERANCE FOR SIZE OR
ALIGNMENT.
K.DO NOT FIELD CUT OR TRIM - IF FIT OR CLEARANCE IS NOT CORRECT, REPLACE DOOR.
L.ADJUST DOORS FOR SMOOTH AND BALANCED DOOR MOVEMENT, ADJUST CLOSERS FOR FULL CLOSURE.
SECTION 08310 - ACCESS DOORS AND PANELS
A.GENERAL: PROVIDE ACCESS DOORS AS REQUIRED FOR ACCESS TO VALVES AND CONTROLS LOCATED BEHIND
FINISHED WALLS AND CEILINGS NOT OTHERWISE ACCESSIBLE, WITH ACCESSORIES FOR COMPLETE INSTALLATION.
1.COORDINATE WITH VARIOUS TRADES FOR CONTROLS AND VALVES WHICH MAY BE CONCEALED.
B.SUBMITTALS: FURNISH PRODUCT DATA FOR EACH TYPE OF ACCESS DOOR AND PANEL.
C.MANUFACTURERS: MILCOR, J.L INDUSTRIES, OR KARP.
D.TYPE: FLUSH TYPE AT NON FIRE RATED CONSTRUCTION, STANDARD U.L. APPROVED FRAMED TYPE AT FIRE RATED
CONSTRUCTION; KEY OPERATED.
1.FRAMES: FABRICATE FROM MINIMUM 16 GAGE.
2.DOORS: FLUSH PANEL TYPE, FABRICATE FROM MINIMUM 14 GAGE STEEL.
3.HINGE: PROVIDE CONTINUOUS PIANO TYPE HINGE.
4.FINISH: FINISH WITH MANUFACTURER'S FACTORY-APPLIED ENAMEL PRIME COAT APPLIED OVER PHOSPHATE
COATING ON STEEL.
E.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE REQUIREMENTS FOR FIRE
RATINGS.
1.SET FRAMES ACCURATELY IN POSITION AND SECURELY ATTACH TO SUPPORTS WITH FACE PANELS PLUMB OR
LEVEL IN RELATION TO ADJACENT FINISH SURFACES.
2.ADJUST HARDWARE AND DOORS AFTER INSTALLATION FOR PROPER OPERATION.
3.REMOVE AND REPLACE DOORS OR FRAMES WHICH ARE WARPED, BOWED OR OTHERWISE DAMAGED.
SECTION 08411 - ALUMINUM FRAMED ENTRANCES & STOREFRONTS
A.GENERAL: PROVIDE AND FURNISH ALL NECESSARY MATERIALS, LABOR, AND EQUIPMENT FOR THE COMPLETE
INSTALLATION OF THE ALUMINUM STOREFRONT SYSTEM AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN.
SECTION INCLUDES MANUFACTURER APPROVED SEALANTS, GLASS, AND GLAZINGS:
1.ALUMINUM SWING DOORS
2.ALUMINUM STOREFRONT SYSTEMS
B.SYSTEM PERFORMANCE: PERFORMANCE REQUIREMENTS MEETING REQUIREMENTS INDICATED AND SOUTH
FLORIDA BUILDING PROTOCOLS TAS 201, TAS 202, AND TAS 203 AND COMPLY WITH THE FOLLOWING
PERFORMANCE REQUIREMENTS.
1.AIR INFILTRATION: AIR INFILTRATION SHALL BE TESTED IN ACCORDANCE WITH ASTM E 283. RESULTS TO
COMPLY WITH MANUFACTURER'S TESTED MAXIMUMS.
2.WATER INFILTRATION: NO UNCONTROLLED WATER OTHER THAN CONDENSATION ON INDOOR FACE OF ANY
COMPONENT TESTED IN ACCORDANCE WITH ASTM E 331. RESULTS TO COMPLY WITH MANUFACTURER'S
TESTED DIFFERENTIALS.
3.WIND LOADS: COMPLETED STOREFRONT SYSTEM SHALL WITHSTAND WIND PRESSURE LOADS NORMAL TO
WALL PLANE INDICATED PER MANUFACTURER'S REQUIREMENTS.
4.DEFLECTION: MAXIMUM ALLOWABLE DEFLECTION IN ANY MEMBER WHEN TESTED SHALL BE IN ACCORDANCE
WITH ASTM E 330 WITH ALLOWABLE STRESS IN ACCORDANCE WITH AAMA SPECIFICATIONS FOR ALUMINUM
STRUCTURES.
5.FORCED ENTRY RESISTANCE: TESTS PERFORMED SIMULTANEOUSLY WITH 300 LB. FORCES APPLIED TO THE
ACTIVE DOOR PANEL WITHIN 3" OF THE LOCKS IN THE DIRECTION THAT WOULD TEND TO OPEN THE DOOR
WHILE 150 LB. FORCES ARE APPLIED IN BOTH PERPENDICULAR DIRECTIONS TO THE 300 LB. FORCE
SIMULTANEOUSLY.
6.THERMAL PERFORMANCE: WHEN TESTED IN ACCORDANCE WITH AAMA 1503 AND NFRC 102, CONDENSATION
RESISTANCE FACTOR TO BE A MINIMUM OF 28 AND THERMAL TRANSMITTANCE U VALUE TO BE 0.77
BTU/HR/FT/FARENHEIGHT OR LESS.
7.THERMAL MOVEMENT: PROVIDE FOR THERMAL MOVEMENT CAUSED BY 180 DEGREES F SURFACE
TEMPERATURE, WITHOUT CAUSING BUCKLING STRESSES ON GLASS, JOINT SEAL FAILURE, UNDUE STRESS ON
STRUCTURAL ELEMENTS, DAMAGING LOADS ON FASTENERS, REDUCTION OF PERFORMANCE, OR DETRIMENTAL
EFFECTS.
C.SUBMITTALS: FURNISH PRODUCT DATA FOR EACH TYPE OF ALUMINUM DOOR & STOREFRONT SYSTEM.
D.MANUFACTURERS: YKK AP AMERICA, INC.
E.WARRANTY: SUBMIT FOR OWNER'S ACCEPTANCE, MANUFACTURER'S STANDARD WARRANTY DOCUMENT
EXECUTED BY AN AUTHORIZED COMPANY OFFICIAL. A MANUFACTURER'S WARRANTY PRIOR OF ONE YEAR
STANDARD COMMENCING ON THE DATE OF SUBSTANTIAL COMPLETION FOR THE PROJECT PROVIDED THAT THE
WARRANTY, IN NO EVENT, SHALL START LATER THAN SIX MONTHS FROM THE DATE OF SHIPMENT BY YKK AP
AMERICA, INC.
F.MATERIALS: PROVIDE FINISHES AS SPECIFIED WITHIN THE CONSTRUCTION DOCUMENTS. SYSTEM TO INCLUDE ANY
MANUFACTURER STANDARD ACCESSORIES/HARDWARE/SEALANTS/FASTENERS IN FINISHES/COLORS COORDINATING
WITH FINISH AS SPECIFIED.
G.EXECUTION: COMPLY WITH MANUFACTURER'S PRODUCT DATA, INCLUDING PRODUCT TECHNICAL BULLETINS,
INSTALLATION INSTRUCTIONS, AND PRODUCT CARTON INSTRUCTIONS. THE LATEST INSTALLATION INSTRUCTIONS
ARE AVAILABLE AT WWW.YKKAP.COM.
1.PROTECT ADJACENT WORK AREAS AND FINISH SURFACES FROM DAMAGE DURING PRODUCT INSTALLATION.
2.INSTALL MANUFACTURER'S SYSTEM IN ACCORDANCE WITH SHOP DRAWINGS, AND WITHIN SPECIFIED
TOLERANCES. SHIM AND BRACE ALUMINUM SYSTEM BEFORE ANCHORING TO STRUCTURE. PROVIDE ALL
NECESSARY FLASHING AND WEEPS TO EXTERIOR.
3.ADJUST SWING DOORS FOR OPERATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
4.THE GENERAL CONTRACTOR SHALL CLEAN INSTALLED PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTION PRIOR TO OWNER'S ACCEPTANCE, AND REMOVE CONSTRUCTION DEBRIS FROM PROJECT SITE.
SECTION 08620 - UNIT SKYLIGHTS
A.GENERAL: PROVIDE UNIT SKYLIGHTS CAPABLE OF WITHSTANDING LOADS INDICATED WITHOUT FAILURE, WITH
ACCESSORIES FOR COMPLETE INSTALLATION. UNIT SKYLIGHTS TO MEET THE REQUIREMENTS OF THE AMERICAN
ARCHITECTURAL MANUFACTURER'S ASSOCIATION (AAMA) PUBLICATION "VOLUNTARY UNIFORM LOAD
STRUCTURAL STANDARD FOR PLASTIC DOMED SKYLIGHTS" (AAMA 1606-82) WHICH REQUIRES ACRYLIC THICKNESS
ADEQUATE TO WITHSTAND A POSITIVE AND NEGATIVE TEST PRESSURE OF 60 PSF. A FAILURE INCLUDES:
1.THERMAL STRESSES TRANSFERRED TO THE BUILDING STRUCTURE.
2.FRAMING MEMBERS TRANSFERRING STRESSES, INCLUDING THOSE CAUSED BY THERMAL AND STRUCTURAL
MOVEMENT, TO GLAZING.
3.NOISE OR VIBRATION CAUSED BY THERMAL AND STRUCTURAL MOVEMENT AND WIND.
4.WEAKENING OF FASTENERS, ATTACHMENTS, AND OTHER COMPONENTS.
B.SUBMITTALS: FOR EACH TYPE OF SKYLIGHT SPECIFIED, INCLUDE DETAILS OF CONSTRUCTION AND INSTALLATION
RELATIVE TO APPLICABLE ROOFING MATERIALS. INCLUDE MANUFACTURER'S COLOR CHARTS SHOWING A FULL
RANGE OF COLORS AVAILABLE FOR EACH TYPE OF SKYLIGHT GLAZING AND ALUMINUM FINISH FOR SELECTION.
C.MANUFACTURERS: WASCO PRODUCTS, INC. OR APPROVED EQUAL.
D.QUALITY ASSURANCE: PROVIDE THERMOFORMED DOME (OUTER) FABRICATION FROM SHEET IDENTICAL TO THOSE
TESTED FOR THE FOLLOWING FIRE-TEST RESPONSE CHARACTERISTICS, PER ASTM TEST OR BY UL OR OTHER TESTING
AND INSPECTING AGENCIES ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. IDENTIFY PLASTIC SHEETS WITH
APPROPRIATE MARKINGS OF APPLICABLE TESTING AND INSPECTING ORGANIZATION.
1.SELF-IGNITION TEMP: ACRYLIC AND IMPACT MODIFIED ACRYLIC 750 DEGREES PER ASTM D 1929.
2.SMOKE DENSITY RATING: ACRYLIC 13.5% OR LESS PER ASTM D 2843, IMPACT MODIFIED ACRYLIC 3.8% AT 6.0
mm OR LESS PER ASTM D 2843-99.
3.RELATIVE BURNING CHARACTERISTICS: TEST PER ASTM D 635
PROVIDE MULTI-WALL CELLULAR POLYCARBONATE PANEL (INNER HORIZONTAL PANEL) FABRICATED FROM AN
APPROVED CELLULAR POLYCARBONATE GLAZING (LIGHT TRANSMITTING) MATERIAL IDENTICAL TO THAT TESTED
WITH A CC1 FIRE RATING CLASSIFICATION PER ASTM D-635 AND FILLED WITH NANOGEL INSULATION.
E.WARRANTY: PROVIDE WRITTEN WARRANTY SIGNED BY MANUFACTURER, AGREEING TO REPAIR OR REPLACE WORK
THAT EXHIBITS DEFECTS IN MATERIALS OR WORKMANSHIP AND GUARANTEEING WEATHER-TIGHT AND LEAK FREE
PERFORMANCE. "DEFECTS" IS DEFINED AS UNCONTROLLED LEAKAGE OF WATER AND ABNORMAL AGING OR
DETERIORATION. WARRANTY PERIOD OF 5 YEARS FROM SUBSTANTIAL COMPLETION ON THE SKYLIGHT, PLASTIC/
ACRYLIC. A WARRANTY OF 1 YEAR FROM DATE OF SUBSTANTIAL COMPLETION FOR FILM INTEGRITY ON ANODIZED
FINISH AND FOR BAKED ENAMEL FINISH.
F.MATERIALS:
1.CURB FRAME: BRIGHT WHITE HIGH PERFORMANCE PVC WITH BRONZE CAP STOCK AND MINIMUM EFFECTIVE
THICKNESS OF 0.060 INCH (1.5MM). PROVIDE INTEGRAL CONDENSATION GUTTER SYSTEM WITH CORNERS
FULLY WELDED FOR WATERPROOF QUALITY.
2.RETAINER FRAME: EXTRUDED ALUMINUM ALLOW 6064-T5 MIN. ASTM B-221 (ASTM B-221 M) WITH MINIMUM
EFFECTIVE THICKNESS OF 0.060 INCH (1.5MM). CURBS TO BE MIN. 1 1/2" WIDE FIELD BUILT OR
PRE-FABRICATED BY OTHERS.
3.PLASTIC SHEETS: MONOLITHIC, FORMABLE, TRANSPARENT (COLORLESS - CLEAR) WITH GOOD WEATHER AND
IMPACT RESISTANT. ACRYLIC TO BE ASTM D-4802, THERMOFORMABLE, ACRYLIC (METHACRYLATE), CATEGORY
C-2 OR CC-2 TYPE UVA (FORMULATED WITH ULTRAVIOLET ABSORBER), WITH FINISH 1 (SMOOTH OR POLISHED),
UNLESS OTHERWISE INDICATED. AVERAGE IMPACT STRENGTH OF 5.0 FT-LB/IN WHEN TESTED PER ASTM D-256
(CHARPY UNNOTCHED). IMPACT MODIFIED ACRYLIC TO BE ASTM D-4802, THERMOFORMABLE, ACRYLIC
(METHACRYLATE) IMPACT MODIFIED SHEETS MANUFACTURED BY THE EXTRUSION PROCESS, CATEGORY C-2 OR
CC-2, TYPE UVA (FORMULATED WITH ULTRAVIOLET ABSORBER) WITH FINISH 1 (SMOOTH OR POLISHED).
AVERAGE IMPACT STRENGTH OF 0.75 FT-LB/INCH (40 J/M OF NOTCH) WHEN TESTED ACCORDING TO ASTM
D-256, TEST METHOD A (IZOD).
4.THERMAL BREAK: FABRICATE SKYLIGHT UNITS WITH THERMAL BARRIER SEPARATING INTERIOR METAL
FRAMING FROM MATERIALS EXPOSED TO OUTSIDE TEMPERATURE.
5.SHAPE & SIZE: AS INDICATED BY MODEL NUMBER.
6.GLAZING: OUTER DOME THERMOFORMED ACRYLIC (CLEAR) OR IMPACT MODIFIED ACRYLIC (CLEAR) WITH 25%
RISE. INNER (HORIZ.) MULTI-WALL TRANSLUCENT CELLULAR POLYCARBONATE PANEL FILLED WITH NANOGEL
INSULATION.
7.FASTENERS: SAME METAL AS METALS BEING FASTENED, OR NONMAGNETIC STAINLESS STEEL OR OTHER
NON-CORROSIVE METAL AS RECOMMENDED BY MANUFACTURER.
8.BITUMINOUS COATING: SSPC-PAINT 12, SOLVENT-TYPE, BITUMINOUS MASTIC, NOMINALLY FREE OF SULFER
AND CONTAINING NO ASBESTOS FIBERS, COMPOUNDED FOR 15-MIL (0.4MM) DRY FILM THICKNESS PER
COATING.
9.ALUMINUM FINISH: CLASS 1, CLEAR ANODIZED FINISH.
G.PLASTIC SKYLIGHT UNITS: FACTORY ASSEMBLED, CURB MOUNTED UNIT CONSISTING OF PLASTIC GLAZING,
GASKETING, INNER FRAME DESIGNED TO MOUNT ON SEPARATE CURB. PROVIDE MODEL AS SPECIFIED IN THE
DRAWINGS TO MEET THE REQUIREMENTS OF THIS SPECIFICATION.
H.INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR PROTECTING, HANDLING, AND
INSTALLING SKYLIGHT COMPONENTS. COORDINATE WITH EXISTING ROOF DECK, VAPOR BARRIERS, ROOF
INSULATION, AND FLASHING AS TO ASSURE THAT EACH ELEMENT OF THE WORK PERFORMS PROPERLY AND THAT
THE COMBINED ELEMENTS ARE WATERPROOF AND WEATHER-TIGHT. ANCHOR UNITS SECURELY TO SUPPORTING
STRUCTURAL SUBSTRATES, ADEQUATE TO WITHSTAND LATERAL AND THERMAL STRESSES AS WELL AS INWARD AND
OUTWARD LOADING PRESSURES. WHERE COUNTER FLASHING IS REQUIRED AS A COMPONENT OF THE SKYLIGHT,
INSTALL TO PROVIDE AN ADEQUATE WATERPROOF OVERLAP WITH ROOFING OR ROOF FLASHING (AS COUNTER
FLASHING). SEAL WITH THICK BEAD OF MASTIC SEALANT, EXCEPT WHERE OVERLAP IS INDICATED TO BE LEFT OPEN
FOR VENTILATION.
I.CLEANING & PROTECTION: CLEAN EXPOSED METAL AND PLASTIC SURFACES ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. TOUCH-UP DAMAGED METAL COATINGS. CLEAN PLASTIC SKYLIGHT UNITS, INSIDE AND OUT, NOT
MORE THAN 5 DAYS PRIOR TO DATE OF SUBSTANTIAL COMPLETION.
SECTION 08700 - HARDWARE
A.GENERAL: PROVIDE DOOR HARDWARE FOR HOLLOW METAL DOORS, WOOD DOORS, AND ALUMINUM/GLASS
DOORS AND PROVIDE CYLINDERS FOR DOORS PROVIDED WITH HARDWARE, WITH ACCESSORIES AS REQUIRED FOR
COMPLETE OPERATIONAL DOOR INSTALLATIONS.
B.STANDARDS: COMPLY WITH BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA) ANSI/BHMA 156 SERIES
STANDARDS, ANSI/ICC A117.1 (AMERICAN NATIONAL STANDARD FOR ACCESSIBLE AND USEABLE BUILDINGS AND
FACILITIES), DHI (DOOR HARDWARE INSTITUTE).
C.CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR
PERSONS WITH DISABILITIES.
1.FIRE RATED DOORS: COMPLY WITH REQUIREMENTS OF NFPA 80 AND APPLICABLE CODES FOR FIRE RATED DOOR
HARDWARE; PROVIDE HARDWARE BEARING UNDERWRITERS LABORATORY (UL) LABELS.
D.SUBMITTALS: FURNISH SHOP DRAWINGS, PRODUCT DATA INCLUDING KEYING SCHEDULE, AND SAMPLES OF EACH
REQUIRED STYLE AND FINISH.
1.SUPPLY TEMPLATES TO DOOR AND FRAME MANUFACTURERS FOR PROPER AND ACCURATE SIZING AND
LOCATIONS OF CUT-OUTS FOR HARDWARE.
E.GENERAL MATERIALS: PROVIDE COMPLETE HARDWARE WITH ACCESSORIES AS REQUIRED FOR DOORS AND
APPLICATIONS INDICATED AND NOT PROVIDED UNDER OTHER SECTIONS.
F.HINGES: HAGER OR EQUAL; FULL MORTISED BUTT HINGES; SIZE AND NUMBER AS RECOMMENDED BY
MANUFACTURER; NONREMOVABLE PINS AT EXTERIOR OUTSWINGING DOORS, BALL-BEARING HINGES AT FIRE
RATED DOORS AND DOORS WITH CLOSERS.
G.LOCKSETS/LATCHSETS: SCHLAGE, ADAMS RITE; AS INDICATED ON THE DRAWINGS, SOLID LEVER TYPE WITH ROSE;
KEYING AS DIRECTED BY TENANT; PROVIDE CYLINDERS FOR DOORS FURNISHED WITH LOCKS.
H.OVERHEAD CLOSERS: HAGER 5200 SERIES OR EQUAL, FULLY ADJUSTABLE; MODERN TYPE WITH COVER.
I.ACCESSORIES: PROVIDE DOOR STOPS, THRESHOLDS, WEATHERSTRIPPING, TRIM, COORDINATORS AND ACCESSORIES
AS REQUIRED FOR COMPLETE OPERATIONAL DOOR INSTALLATION.
1.THRESHOLDS, STOPS, TRIM, AND MISCELLANEOUS HARDWARE: PROVIDE AS INDICATED, AS SPECIFIED, AS
INCLUDED IN HARDWARE SCHEDULE, AND AS REQUIRED FOR COMPLETE INSTALLATION.
2.WEATHERSTRIPPING: PROVIDE CONTINUOUS WEATHERSTRIPPING AT TOP AND SIDES OF EXTERIOR DOORS.
3.FIRE RATED GASKETS: PROVIDE CONTINUOUS FIRE RATED GASKETS AT TOP AND SIDES OF FIRE RATED DOORS.
4.THROUGH BOLTS: THROUGH BOLTS AND GROMMET NUTS SHALL BE AVOIDED ON DOOR FACES IN HIGHLY
VISIBLE AREAS, UNLESS NO ALTERNATIVE IS POSSIBLE, AS DIRECTED AND APPROVED, AND SHALL NOT BE USED
FOR SOLID WOOD CORE DOORS.
J.FINISH: BHMA 626 (US26D), SATIN FINISHED CHROMIUM PLATED UNLESS OTHERWISE INDICATED.
K.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPLICABLE REQUIREMENTS
FOR ACCESS AND FOR FIRE RATINGS.
1.FIT HARDWARE PRIOR TO PAINTING, THEN REMOVE FOR PAINTING/FINISHING OF DOORS AND FRAMES BEFORE
FINAL INSTALLATION OF HARDWARE.
2.HEIGHTS TO COMPLY WITH APPLICABLE CODES AND BHMA RECOMMENDATIONS.
3.ADJUST HARDWARE FOR SMOOTH OPERATION.
4.HARDWARE GROUPS: REFER TO DRAWINGS.
SECTION 08810 - GLAZING
A.GENERAL: PROVIDE GLAZING AND GLAZING ACCESSORIES FOR DOORS, FRAMES, SIDELIGHTS, ETC. AS REQUIRED FOR
A COMPLETE INSTALLATION AS INDICATED ON THE DRAWINGS.
B.STANDARDS: ASTM C1036 (STANDARD SPECIFICATION FOR FLAT GLASS), ASTM C1048 (STANDARD SPECIFICATION
FOR HEAT TREATED FLAT GLASS), AND ASTM E2190 (STANDARD SPECIFICATION FOR INSULATING GLASS UNIT
PERFORMANCE ADN EVALUATION).
C.PERFORM WORK IN ACCORDANCE WITH GANA GLAZING MANUAL AND FGMA SEALANT MANUAL FOR GLAZING
INSTALLATION METHODS. DO NO INSTALL GLAZING WHEN AMBIENT TEMPERATURE IS LESS THAN 50 DEGREES F.
D.PROVIDE A 5 YEAR WARRANTY ON SEALED INSULATING GLASS UNITS TO INCLUDE COVERAGE FOR SEAL FAILURE,
INTERPANE DUSTING OR MISTING, INCLUDING REPLACEMENT OF FAILED UNITS. PROVIDE A 5 YEAR WARRANTY OF
LAMINATED GLASS TO INCLUDE COVERAGE FOR DELAMINATION, INCLUDING REPLACEMENT OF FAILED UNITS.
E.GLAZING TYPES: AS INDICATED ON THE DRAWINGS.
F.FLOAT GLASS:
1.ANNEALED TYPE:ASTM C1036, TYPE 1, TRANSPARENT FLAT, CLASS 1 CLEAR, QUALITY Q3.
2.HEAT STRENGTHEN AND FULLY TEMPERED TYPE: ASTM C1048
3.LAMINATED GLASS: ASTM C1172
G.SEALED/INSULATING GLASS UNITS: CERTIFIED BY AN INDEPENDENT TESTING AGENCY TO COMPLY WITH ASTM
E2190. ALUMINUM, BENT AND SOLID CORNER EDGE SPACERS. GLASS TO ELASTOMER WITH SUPPLEMENTARY
SILICONE SEALANT EDGE SEAL - PURGE INNER SPACE WITH DRY HERMETIC AIR.
H.GLAZING COMPOUNDS:
1.BUTYL SEALANT - SINGLE COMPONENT, SHORE A HARDNESS OF 10 TO 20, BLACK COLOR, NON-SKINNING.
2.SILICONE SEALANT - SINGLE COMPONENT, CHEMICAL CURING, CAPABLE OF WATER IMMERSION WITHOUT LOSS
OF PROPERTIES, NON-BLEEDING, NON-STAINING, ASTM C920, TYPE S, GRADE NS, CLASS 25, CURED SHORE
HARDNESS OF 15 TO 25. COLOR AS SELECTED FROM MANUFACTURER'S STANDARD COLORS.
I.GLAZING ACCESSORIES: SETTING BLOCKS, SPACER SHIMS, GLAZING TAPE, GLAZING GASKETS, GLAZING CLIPS, ETC.
AS REQUIRED FOR A COMPLETE INSTALLATION.
J.VERIFY THAT OPENINGS FOR GLAZING ARE CORRECTLY SIZED AND WITHIN TOLERANCE. VERIFY THAT GLAZING
CHANNELS OR RECESSES ARE CLEAN, FREE OF OBSTRUCTIONS THAT MAY IMPEDE MOISTURE MOVEMENT, AND ARE
READY TO RECEIVE GLAZING.
K.INSTALL GLAZING BY METHOD RECOMMENDED BY GLAZING AND FRAME MANUFACTURER PER ALL MANUFACTURER
INSTRUCTIONS.
L.INSTALL SEALANTS IN ACCORDANCE WITH ASTM C1193 AND FGMA SEALANT MANUAL. INSTALL SEALANTS IN
ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS.
DIVISION NINE: FINISHES
SECTION 09260 - GYPSUM BOARD ASSEMBLIES (WALLS AND CEILINGS)
A.GENERAL: PROVIDE GYPSUM BOARD SYSTEMS INCLUDING METAL FRAMING ACCESSORIES, GYPSUM BOARD, JOINT
TREATMENT, ACOUSTICAL INSULATION, ACOUSTICAL SEALANT, AND ACCESSORIES AS REQUIRED FOR COMPLETE
INSTALLATION.
B.STANDARDS: COMPLY WITH ASTM C754, ASTM C840, AND REQUIREMENTS FOR FIRE RATINGS.
1.DEFLECTIONS: MAXIMUM L/240 TYP., L/360 AT LOCATIONS INDICATED TO RECEIVE TILE.
C.FIRE-RATED ASSEMBLIES: LISTED BY UNDERWRITER'S LABORATORY, GYPSUM ASSOCIATION (GA) FILE NO'S IN GA-600
FIRE RESISTANCE DESIGN MANUAL, OR OTHER LISTING APPROVED BY APPLICABLE AUTHORITIES.
D.SYSTEMS RESPONSIBILITY: PROVIDE PRODUCTS MANUFACTURED BY OR RECOMMENDED BY MANUFACTURER OF
GYPSUM BOARD TO MAINTAIN SINGLE-SOURCE RESPONSIBILITY FOR SYSTEM.
E.SUBMITTALS: FURNISH PRODUCT DATA.
F.MANUFACTURERS: USG, GEORGIA PACIFIC, OR NATIONAL GYPSUM.
G.METAL FRAMING: CONFORM TO ASTM C754; COMPLETE 16 GAGE CEILING FRAMING AND MIN. 22 GAGE STUDS
WALL FRAMING FOR GYPSUM BOARD SYSTEMS; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE
INSTALLATION.
1.MANUFACTURED SUSPENSION SYSTEM SUCH AS CHICAGO METALLIC/DRYWALL SYSTEM IS ACCEPTABLE.
H.GYPSUM BOARD: CONFORM TO ASTM C840; U.L. LISTED FIRE RESISTANT GYPSUM BOARD.
1.STANDARD: ASTM C1396, 5/8" THICK.
2.CORE BOARD: ASTM C1396, 1" THICK.
I.GYPSUM BOARD ACCESSORIES: COMPLY WITH ASTM C840.
1.PROVIDE PROTECTIVE COATED STEEL CORNER BEADS AND EDGE TRIM; TYPE DESIGNED TO BE CONCEALED IN
FINISHED CONSTRUCTION BY TAPE AND JOINT COMPOUND.
2.CORNER BEADS: MANUFACTURER'S STANDARD METAL BEADS.
3.REINFORCING TAPE, JOINT COMPOUND, ADHESIVE, WATER, FASTENERS: TYPES RECOMMENDED BY SYSTEM
MANUFACTURER AND CONFORMING WITH ASTM C475.
J.FIRE RATED CONSTRUCTION: COMPLY WITH UNDERWRITER'S LABORATORIES CERTIFIED FIRE TESTS AND APPLICABLE
CODE REQUIREMENTS.
1.SHAFT WALL SYSTEM: PROVIDE AT SHAFTS AND WHERE INDICATED.
K.ACOUSTICAL ACCESSORIES: PROVIDE ASTM C665, TYPE I ACOUSTICAL INSULATION AND ASTM C919 PAINTABLE
ACOUSTICAL SEALANTS WHERE ACOUSTICAL SYSTEMS ARE INDICATED.
L.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS, AND APPLICABLE
REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS.
M.METAL FRAMING ERECTION: ERECT METAL FRAMING IN ACCORDANCE WITH ASTM C754 AND MANUFACTURER'S
RECOMMENDATIONS.
1.INSTALL MEMBERS TRUE TO LINES AND LEVELS TO PROVIDE SURFACE FLATNESS WITH MAXIMUM VARIATION
OF 1/8" IN 10'-0" IN ANY DIRECTION.
2.DOOR OPENING FRAMING: INSTALL DOUBLE STUDS AT DOOR FRAME JAMBS; INSTALL RUNNERS ON EACH SIDE
OF OPENING AT FRAME HEAD HEIGHT BETWEEN JAMB STUDS AND ADJACENT STUDS.
3.INSTALL METAL FRAMING BACKING WHERE REQUIRED FOR SUPPORT OF FIXTURES, CABINETS, ACCESSORIES
AND HARDWARE.
4.COORDINATE INSTALLATION OF BUCKS, ANCHORS, BLOCKING, ELECTRICAL AND MECHANICAL WORK WHICH IS
TO BE PLACED IN OR BEHIND PARTITION FRAMING; ALLOW ITEMS TO BE INSTALLED AFTER FRAMING IS
COMPLETE.
N.CEILING FRAMING INSTALLATION: ERECT IN ACCORDANCE WITH ASTM C754 AND MANUFACTURER'S
RECOMMENDATIONS. REINFORCE OPENINGS IN CEILING SUSPENSION SYSTEM.
1.LATERALLY BRACE ENTIRE SUSPENSION SYSTEM.
O.GYPSUM BOARD INSTALLATION: INSTALL IN ACCORDANCE WITH ASTM C840 AND MANUFACTURER'S
RECOMMENDATIONS. USE SCREWS WHEN FASTENING GYPSUM BOARD TO FURRING AND TO FRAMING.
1.FOR FIRE RATED SYSTEMS COMPLY WITH REQUIREMENTS FOR FIRE RATINGS.
2.PLACE CORNER BEADS AT EXTERNAL CORNERS; USE LONGEST PRACTICAL LENGTHS.
3.PLACE EDGE TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS.
4.TAPE, FILL, AND SAND EXPOSED JOINTS, EDGES, CORNERS AND OPENINGS TO PRODUCE SURFACE READY TO
RECEIVE FINISHES; FEATHER COATS ONTO ADJOINING SURFACES.
5.FINISHING: COMPLY WITH GYPSUM ASSOCIATION (GA) "LEVELS OF GYPSUM BOARD FINISH" GA LEVEL 4, THREE
COAT FINISHING AND SANDING IS REQUIRED FOR ALL SURFACES TO BE FINISHED; PROVIDE FLUSH, SMOOTH
JOINTS AND SURFACES READY FOR APPLIED PAINT AND WALL COVERING FINISHES.
6.REMOVE AND REPLACE DEFECTIVE WORK.
P.ACOUSTICAL ACCESSORIES INSTALLATION.
1.PLACE ACOUSTICAL INSULATION TIGHT WITHIN SPACES, AROUND CUT OPENINGS, BEHIND AND AROUND
ELECTRICAL AND MECHANICAL ITEMS WITHIN PARTITIONS, AND TIGHT TO ITEMS PASSING THROUGH
PARTITIONS.
2.PLACE ACOUSTICAL SEALANT WITHIN PARTITIONS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS; INSTALL ACOUSTICAL SEALANT AT GYPSUM BOARD PERIMETER, AT BASE LAYER AND
FACE LAYER OF GYPSUM BOARD, AND PENETRATIONS OF PARTITIONS.
3.TOLERANCE: MAXIMUM 1/4" SPACE BETWEEN GYPSUM BOARD AT FLOOR, CEILING, AND PENETRATIONS.
4.INSTALL ELECTRICAL BOX PADS WITH PADS MOLDED AND PRESSED ON BACK SIDE OF BOX, CLOSING OPENINGS,
IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, FOR COMPLETE ACOUSTICAL BARRIER.
SECTION 09300 - TILE
A.GENERAL: PROVIDE TILE SYSTEMS INCLUDING SETTING MATERIALS, GROUT, AND ACCESSORIES AS REQUIRED FOR
COMPLETE FINISHED INSTALLATION.
B.STANDARDS: COMPLY WITH TILE COUNCIL OF AMERICA "HANDBOOK OF CERAMIC TILE INSTALLATION" INCLUDING
REFERENCED ASTM AND ANSI STANDARDS.
C.SUBMITTALS: SUBMIT PRODUCT DATA AND SAMPLES OF EACH TYPE OF TILE AND GROUT.
D.TILE MANUFACTURERS: AS INDICATED ON DRAWINGS.
1.FLOOR TILE: PROVIDE NON-SLIP UNITS WITH MINIMUM WET AND DRY VALUE OF 0.60 COEFFICIENT OF
FRICTION WHEN TESTED IN ACCORDANCE WITH ASTM C1028.
E.LATEX THIN SET: THINSET BOND COAT, LATEX-CEMENTITIOUS MORTAR CONFORMING TO ANSI A118.4.
F.GROUT: ANSI A118.6, LATEX CEMENTITIOUS TYPE BY LATICRETE, BOSTIK OR MAPEI.
G.INTEGRAL WATERPROOFING: LATICRETE, BOSTIK, OR NOBEL LIQUID RUBBER INTEGRAL TILE SETTING
WATERPROOFING SYSTEM WITH NO BITUMINOUS EXTENDERS; PROVIDE AT TILE APPLICATIONS ABOVE GRADE.
H.CLEANING AND SEALING MATERIALS: AS RECOMMENDED BY TILE AND GROUT MANUFACTURERS, SUCH AS BOSTIK
CONSTRUCTION PRODUCTS/HYDROMENT CERAMASEAL.
I.PREPARATION: DO NOT COMMENCE WORK UNTIL SURFACE CONDITIONS ARE WITHIN TOLERANCES REQUIRED FOR
PROPER INSTALLATION; APPLY LATEX LEVELING MATERIAL WHERE NECESSARY TO MEET REQUIRED TOLERANCES.
J.INSTALLATION: COMPLY WITH TILE COUNCIL OF AMERICA (TCA) HANDBOOK FOR CERAMIC TILE INSTALLATION FOR
LATEX BOND COAT THIN SET APPLICATION.
1.TILE: INSTALL TILE IN ACCORDANCE WITH REFERENCED ANSI STANDARDS AND TCA RECOMMENDATIONS FOR
TYPE OF SUBSTRATE AND INDICATED SETTING METHOD; LATEX-CEMENT THIN SET AND BOND COATS REQUIRED.
2.PLACE TILE IN ACCORDANCE WITH PATTERNS INDICATED ON DRAWINGS; CAREFULLY PLAN TILE LAYOUTS,
ENSURE PATTERN IS UNINTERRUPTED FROM ONE SURFACE TO THE NEXT AND THROUGH DOORWAYS.
3.SEAL TILE AND GROUT SURFACES WHERE RECOMMENDED BY MANUFACTURER FOR MATERIALS AND
APPLICATIONS INVOLVED; COMPLY WITH MANUFACTURER'S RECOMMENDATIONS.
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
SPECIFICATIONS
SP.2
SECTION 09510 - ACOUSTICAL CEILING
A.GENERAL: PROVIDE ACOUSTICAL CEILINGS INCLUDING SUSPENSION SYSTEM, TRIM, AND ACCESSORIES AS REQUIRED
FOR COMPLETE FINISHED INSTALLATION.
B.STANDARDS: CONFORM TO ASTM C635 FOR METAL SUSPENSION SYSTEM AND ASTM C636 FOR INSTALLATION OF
ACOUSTICAL CEILINGS.
C.PERFORMANCE REQUIREMENTS: PROVIDE PRODUCTS LISTED BY UNDERWRITERS LABORATORIES (U.L.).
1.FLAME SPREAD/SMOKE DENSITY: PROVIDE PRODUCTS MEETING CODE REQUIREMENTS FOR MAXIMUM 25
FLAME SPREAD AND MAXIMUM 25 SMOKE DENSITY.
D.SEISMIC REQUIREMENTS: COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS FOR SEISMIC BRACING OF
CEILING SUSPENSION SYSTEM, AND WITH ASTM E580.
E.SUBMITTALS: SUBMIT PRODUCT DATA, SHOP DRAWINGS INDICATING LAYOUT, AND SAMPLES OF GRID, TRIM, AND
CEILING UNITS.
F.INSTALLER: FIRM WITH MINIMUM THREE YEAR'S SUCCESSFUL EXPERIENCE IN PROJECTS OF SIMILAR TYPE AND
SCOPE; ACCEPTABLE TO MANUFACTURER OF ACOUSTICAL UNITS.
G.PROJECT CONDITIONS: DO NOT INSTALL CEILINGS UNTIL BUILDING IS ENCLOSED, SUFFICIENT HEAT IS PROVIDED,
DUST GENERATING ACTIVITIES HAVE TERMINATED AND OVERHEAD MECHANICAL WORK IS COMPLETED, TESTED
AND APPROVED; ALLOW WET WORK TO DRY PRIOR TO INSTALLATION.
H.ACOUSTICAL UNITS: TYPES AND MANUFACTURERS AS INDICATED ON DRAWINGS.
I.SUSPENSION SYSTEM: AS INDICATED ON DRAWINGS.
J.PREPARATION: MEASURE CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL UNITS TO BALANCE BORDER
WIDTHS AT OPPOSITE EDGES OF EACH CEILING; DO NOT USE LESS THAN HALF WIDTH UNITS AT BORDERS.
1.COORDINATE WITH OTHER WORK SUPPORTED BY OR PENETRATING THROUGH CEILINGS, INCLUDING LIGHT
FIXTURES, HVAC EQUIPMENT AND PARTITION SYSTEMS.
K.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, ASTM C636, AND APPLICABLE
REQUIREMENTS FOR FIRE RATINGS.
1.FINISHED CEILINGS: TRUE TO LINES AND LEVELS AND FREE FROM WARPED, SOILED OR DAMAGED GRID OR
ACOUSTICAL UNITS.
2.INSTALL CEILING SYSTEMS IN A MANNER CAPABLE OF SUPPORTING SUPERIMPOSED LOADS, WITH MAXIMUM
PERMISSIBLE DEFLECTION OF 1/8" IN 10'-0".
3.ENSURE SUSPENSION SYSTEM IS LOCATED TO ACCOMMODATE FITTINGS AND UNITS OF EQUIPMENT WHICH IS
TO BE PLACED AFTER INSTALLATION OF CEILING GRID.
4.WHERE DUCTS OR OTHER EQUIPMENT PREVENT REGULAR SPACING OF HANGERS, REINFORCE NEAREST
ADJACENT HANGERS AND RELATED CARRYING CHANNELS AS REQUIRED TO SPAN REQUIRED DISTANCE.
5.INSTALL EDGE MOLDINGS AT INTERSECTION OF CEILING AND VERTICAL SURFACES, USING MAXIMUM LENGTHS,
STRAIGHT, TRUE TO LINE AND LEVEL; MITER CORNERS.
6.FIT ACOUSTIC UNITS IN PLACE, FREE FROM DAMAGED EDGES OR DEFECTS DETRIMENTAL TO APPEARANCE AND
FUNCTION. LAY DIRECTIONALLY PATTERNED UNITS ONE WAY WITH PATTERN AS DIRECTED. FIT BORDER UNITS
NEATLY AGAINST ABUTTING SURFACES.
7.INSTALL UNITS LEVEL, IN UNIFORM PLANE AND FREE FROM TWIST, WARP AND DENTS.
8.INSTALL HOLD-DOWN CLIPS WHERE REQUIRED BY APPLICABLE CODES AND WHERE CEILING IS WITHIN 20'-0" OF
AN EXTERIOR DOOR.
L.ADJUSTMENT: ADJUST SAGS OR TWISTS WHICH DEVELOP IN CEILING SYSTEM AND REPLACE ANY PART WHICH IS
DAMAGED OR FAULTY.
SECTION 09650 - RESILIENT TILE FLOORING
A.GENERAL: PROVIDE RESILIENT TILE FLOORING SYSTEM AND RESILIENT BASE, WITH ACCESSORIES AS REQUIRED FOR
COMPLETE FINISHED INSTALLATION.
B.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF FLOORING AND BASE COLOR AND PATTERN
SELECTED.
C.PROJECT CONDITIONS: ENSURE FLOOR SURFACES ARE SMOOTH AND FLAT WITH MAXIMUM VARIATION OF 1/8" IN
10'-0"; ENSURE CONCRETE FLOORS ARE DRY AND EXHIBIT NEGATIVE ALKALINITY, CARBONIZING AND DUSTING.
D.RESILIENT TILE: VINYL COMPOSITION TILE CONFORMING TO ASTM F1066, COMPOSITION 1; COLOR AND PATTERN AS
INDICATED ON THE DRAWINGS.
1.MANUFACTURERS/PRODUCTS: AS INDICATED ON THE DRAWINGS.
2.FLAMMABILITY: PROVIDE MATERIALS TESTED UNDER ASTM E648, FLOORING RADIANT PANEL TEST, WITH
RESULTS OF 0.45 WATTS/CM2 OR HIGHER.
3.SLIP RESISTANCE: PROVIDE MATERIALS TESTED UNDER ASTM D2047, JAMES SLIP TEST WITH MINIMUM 0.6
RATING FOR FLOORS.
E.RESILIENT BASE: FS SS-W-40, 1/8" GAGE COVED BASE AT HARD FLOOR SURFACES, STRAIGHT (TOP SET) AT CARPET
SURFACES; PROVIDE PREMOLDED END STOPS AND EXTERNAL CORNERS.
1.MANUFACTURERS: AS INDICATED ON THE DRAWINGS.
2.HEIGHT: 4" UNLESS OTHERWISE INDICATED.
3.COLOR: SEE FINISH SCHEDULE.
F.EDGE STRIPS AND ACCESSORIES: RUBBER OR VINYL EDGE STRIPS MATCHING RESILIENT FLOORING; LATEX-MODIFIED
PORTLAND CEMENT BASED UNDERLAYMENT AND PATCHING COMPOUND; NONTOXIC WATER RESISTANT TYPE
ADHESIVES.
G.SUBFLOOR FILLER: WHITE PREMIXED LATEX-CEMENT PASTE DESIGNED FOR PROVIDING THIN SOLID SURFACE FOR
LEVELING AND MINOR RAMPING OF SUBSURFACE TO ADJACENT FLOOR FINISHES; MATERIAL CAPABLE OF BEING
APPLIED AND FEATHERED OUT TO ADJACENT FLOOR WITHOUT SPALLING.
H.PRIMERS AND ADHESIVES: WATERPROOF NONTOXIC TYPES AS RECOMMENDED BY FLOORING MANUFACTURER FOR
SPECIFIED MATERIAL AND APPLICATION.
I.SEALER AND WAX: TYPE RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIAL TYPE AND LOCATION.
J.PREPARATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION AND WITH ASTM F710;
REMOVE SUBFLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS, JOINTS, HOLES AND DEFECTS WITH SUBFLOOR
FILLER.
K.FLOORING INSTALLATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION
INSTRUCTIONS; SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER TO ENSURE FULL ADHESION; SCRIBE FLOORING
TO WALLS, COLUMNS, AND OTHER APPURTENANCES TO PRODUCE TIGHT JOINTS.
1.INSTALL MINIMUM 1/2 TILE AT ROOM AND AREA PERIMETER; TERMINATE RESILIENT FLOORING AT CENTERLINE
OF DOOR OPENINGS WHERE ADJACENT FLOOR FINISH IS DISSIMILAR; INSTALL EDGE STRIPS AT UNPROTECTED
AND EXPOSED EDGES WHERE FLOORING TERMINATES.
L.BASE INSTALLATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS;
APPLY TO WALLS, COLUMNS, PILASTERS, CASEWORK, AND OTHER PERMANENT FIXTURES IN ROOMS AND AREAS
WHERE BASE IS REQUIRED.
1.MITER INTERNAL CORNERS; USE PREMOLDED SECTIONS FOR EXTERNAL CORNERS AND EXPOSED ENDS; SCRIBE
AND FIT TO DOOR FRAMES AND OTHER OBSTRUCTIONS.
M.EDGE STRIPS: INSTALL WHERE EDGE OF TILE WOULD OTHERWISE BE EXPOSED; BUTT TO FLOORING WITHOUT GAPS;
SET IN ADHESIVE.
N.CLEANING: CLEAN, SEAL AND WAX FLOOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
SECTION 09655 - RESILIENT SHEET FLOORING
A.GENERAL: PROVIDE RESILIENT SHEET FLOORING WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED
INSTALLATION.
B.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF FLOORING COLOR AND PATTERN SELECTED
AND EACH TYPE OF EXPOSED INTEGRAL BASE ACCESSORY.
C.PROJECT CONDITIONS: ENSURE FLOOR SURFACES ARE SMOOTH AND FLAT WITH MAXIMUM VARIATION OF 1/8" IN
10'-0"; ENSURE CONCRETE FLOORS ARE DRY AND EXHIBIT NEGATIVE ALKALINITY, CARBONIZING AND DUSTING.
D.VINYL SHEET FLOORING: NOMINAL 0.080" THICK VINYL SHEET CONFORMING TO FS L-F-475, TYPE II, GRADE A.;
COLOR AS INDICATED, AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE OF COLORS WHERE NOT
OTHERWISE INDICATED.
1.MANUFACTURERS: LONSEAL, MANNINGTON, OR TOLI.
2.FLAMMABILITY: 0.45 WATTS/SQ.CM. OR HIGHER, ASTM E648.
E.INTEGRAL BASE ACCESSORIES: PROVIDE MANUFACTURER'S STANDARD COVE SUPPORT STRIPS AND FINISHED METAL
TOP EDGE STRIPS; TYPE AND COLORS AS SELECTED BY ARCHITECT FROM MANUFACTURERS FULL RANGE.
F.EDGE STRIPS AND ACCESSORIES: RUBBER OR VINYL EDGE STRIPS MATCHING RESILIENT FLOORING.
G.SUBFLOOR FILLER: WHITE PREMIXED LATEX-CEMENT PASTE DESIGNED FOR PROVIDING THIN SOLID SURFACE FOR
LEVELING AND MINOR RAMPING OF SUBSURFACE TO ADJACENT FLOOR FINISHES. USE MATERIAL CAPABLE OF BEING
APPLIED AND FEATHERED OUT TO ADJACENT FLOOR WITHOUT SPALLING.
H.PRIMERS AND ADHESIVES: WATERPROOF NONTOXIC TYPES AS RECOMMENDED BY FLOORING MANUFACTURER FOR
SPECIFIED MATERIAL AND APPLICATION.
I.SEALER AND WAX: TYPE RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIAL TYPE AND LOCATION.
J.PREPARATION: CONFORM WITH ASTM F710 AND MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION;
REMOVE SUBFLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS, JOINTS, HOLES AND DEFECTS WITH SUBFLOOR
FILLER.
K.INSTALLATION: COMPLY WITH FLOORING AND BASE MANUFACTURER RECOMMENDATIONS AND INSTALLATION
INSTRUCTIONS; SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER FOR FULL ADHESION; SCRIBE TO WALLS,
COLUMNS, AND OTHER APPURTENANCES TO PRODUCE TIGHT JOINTS
1.LAY FLOORING WITH MINIMUM SEAMS, WITH PATTERN PARALLEL TO BUILDING LINES TO PRODUCE
SYMMETRICAL PATTERN; TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR OPENINGS WHERE
ADJACENT FLOOR FINISH IS DISSIMILAR; INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES.
L.WAXING: CLEAN, SEAL AND WAX FLOOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
M.CLEANING: REMOVE EXCESS ADHESIVE FROM FLOOR, BASE AND WALL SURFACES.
SECTION 09680 - CARPET
A.GENERAL: PROVIDE CARPET AND ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION.
B.STANDARDS: CRI 104 - STANDARD FOR INSTALLATION OF COMMERCIAL TEXTILE FLOOR COVERING MATERIALS.
C.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF CARPET SPECIFIED.
D.INSTALLER: FIRM WITH MINIMUM FIVE YEARS EXPERIENCE IN PROJECTS OF SIMILAR TYPE AND SCOPE.
E.MANUFACTURERS AND PRODUCTS: AS INDICATED ON THE DRAWINGS.
F.ACCESSORIES:
1.SUB-FLOOR FILLER AS RECOMMENDED BY MANUFACTURER.
2.ADHESIVES COMPATIBLE WITH MATERIALS BEING ADHERED, INCLUDING SEAM ADHESIVE AND CONTACT
ADHESIVE.
G.PREPARATION: VERIFY AND CONFORM WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION; REMOVE
SUB-FLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS, JOINTS, HOLES, AND DEFECTS WITH SUBFLOOR FILLER.
H.THOROUGHLY CLEAN SUBSTRATE.
I.INSTALLATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS.
1.VERIFY CARPET MATCH BEFORE CUTTING TO ENSURE MINIMAL VARIATION BETWEEN DYE LOTS.
2.LOCATE SEAMS IN AREA OF LEAST TRAFFIC, DO NOT LOCATE SEAMS PERPENDICULAR THROUGH DOOR
OPENINGS.
3.ALIGN RUN OF PILE IN SAME DIRECTION AS ANTICIPATED TRAFFIC AND IN SAME DIRECTION ON ADJACENT
PIECES.
4.LOCATE CHANGE OF COLOR OR PATTERN BETWEEN ROOMS UNDER DOOR CENTERLINE.
J.DIRECT GLUE CARPET:
1.DOUBLE CUT CARPET SEAMS, WITH ACCURATE PATTERN MATCH. MAKE CUTS STRAIGHT, TRUE, AND
UNFRAYED.
2.APPLY CONTACT ADHESIVE TO FLOOR UNIFORMLY AT RATE RECOMMENDED BY MANUFACTURER. AFTER
SUFFICIENT TIME, PRESS CARPET INTO ADHESIVE.
3.APPLY SEAM ADHESIVE TO THE BASE OF THE EDGE GLUED DOWN. LAY ADJOINING PIECE WITH SEAM STRAIGHT,
NOT OVERLAPPED OR PEAKED, AND FREE OF GAPS.
4.ROLL WITH APPROPRIATE ROLLER OF COMPLETE CONTACT OF ADHESIVE TO CARPET BACKING, TRIM NEATLY AT
WALL AND AROUND INTERRUPTIONS.
K.CARPET TILES:
1.BLEND CARPET FROM DIFFERENT CARTONS TO ENSURE MINIMAL VARIATION IN COLOR MATCH.
2.CUT CARPET TILE CLEAN. FIT CARPET TIGHT TO INTERSECTION WITH VERTICAL SURFACES WITHOUT GAPS.
3.LAY CARPET TILE IN PATTERN INDICATED ON THE DRAWINGS.
4.LOCATE CHANGE OF COLOR OR PATTERN BETWEEN ROOMS UNDER DOOR CENTERLINE.
5.FULLY ADHERE CARPET TILE TO SUBSTRATE.
6.TRIM NEATLY AT WALLS AND AROUND INTERRUPTIONS, COMPLETE INSTALLATION OF EDGE STRIPS,
CONCEALING EXPOSED EDGES.
L.REMOVE EXCESS ADHESIVES WITHOUT DAMAGE, FROM FLOOR, BASE AND WALL SURFACES.
M.CLEAN AND VACUUM CARPET SURFACES.
SECTION 09900 - PAINTS AND COATINGS
A.GENERAL: PROVIDE PAINTING OF EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS REQUIRED FOR COMPLETE
FINISHED INSTALLATION.
B.SURFACES NOT TO BE PAINTED: PREFINISHED ITEMS; CONCEALED AND INACCESSIBLE AREAS, CODE-REQUIRED
LABELS.
C.STANDARDS: PROVIDE MATERIALS APPROVED FOR USE BY APPLICABLE AIR QUALITY MANAGEMENT DISTRICT FOR
LIMITATIONS OF VOLATILE ORGANIC COMPOUNDS FOR ARCHITECTURAL COATINGS.
D.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES.
1.DUPLICATE PAINTED FINISHES OF APPROVED SAMPLES ON ACTUAL WALL SURFACES AND COMPONENTS FOR
APPROVAL PRIOR TO COMMENCING WORK.
E.DELIVERY: DELIVER MATERIALS TO JOB SITE IN ORIGINAL, NEW AND UNOPENED PACKAGES AND CONTAINERS
BEARING MANUFACTURER'S NAME AND LABEL.
F.MANUFACTURERS: SHERWIN-WILLIAMS OR BENJAMIN MOORE.
G.MATERIAL QUALITY: PROVIDE TOP LINE QUALITY COMMERCIAL GRADE (PROFESSIONAL PAINTER) PAINTS;
MATERIALS NOT BEARING MANUFACTURER'S IDENTIFICATION AS A BEST-GRADE PRODUCT SHALL NOT BE
ACCEPTABLE.
1.PRIMERS: PROVIDE PREMIUM GRADE PRIMERS RECOMMENDED BY PAINT MANUFACTURER FOR SUBSTRATES
INDICATED AND FOR FINISH SYSTEMS SPECIFIED.
2.UNDERCOATS AND BARRIER COATS: PROVIDE UNDERCOAT PAINTS PRODUCED BY SAME MANUFACTURER AS
FINISH COATS; USE ONLY THINNERS APPROVED BY PAINT MANUFACTURER, AND USE ONLY WITHIN
RECOMMENDED LIMITS.
3.FINISH COATS: PROVIDE FINISH COATS CAPABLE OF BEING WASHED WITH MILD DETERGENT WITHOUT LOSS OF
COLOR, SHEEN, OR PIGMENTS.
4.FINISH COAT COORDINATION: PROVIDE FINISH COATS WHICH ARE COMPATIBLE WITH PRIME PAINTS,
UNDERCOATS, AND BARRIER COATS USED.
5.VOLATILE ORGANIC COMPOUNDS: PROVIDE MATERIALS WITH MINIMAL VOLATILE ORGANIC COMPOUNDS
(VOC); COMPLY WITH APPLICABLE REGULATIONS.
H.COLORS AND FINISHES: PURE, NON-FADING, APPLICABLE TYPES TO SUIT SERVICE INDICATED; NO LEAD CONTENT
PERMITTED.
1.COLORS AS INDICATED ON THE DRAWINGS.
I.PREPARATION: PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH PAINT
MANUFACTURER'S INSTRUCTIONS AND AS SPECIFIED FOR SUBSTRATE CONDITION.
1.EXAMINE AREAS AND CONDITIONS UNDER WHICH PAINTING WORK IS TO BE APPLIED. START OF PAINTING
WORK INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS OF SURFACES AND CONDITIONS WITHIN ANY
PARTICULAR AREA.
2.REMOVE HARDWARE, ACCESSORIES, AND ITEMS IN PLACE AND NOT TO BE PAINTED, OR PROVIDE PROTECTION
PRIOR TO SURFACE PREPARATION AND PAINTING; AFTER PAINTING REINSTALL REMOVED ITEMS.
J.APPLICATION: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS; USE APPLICATORS AND
TECHNIQUES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED.
1.APPLY ADDITIONAL COATS WHEN STAINS OR BLEMISHES SHOW THROUGH FINAL COAT, UNTIL PAINT IS A
UNIFORM FINISH, COLOR AND APPEARANCE.
2.FINISH DOORS ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES.
3.PROVIDE EXTRA ATTENTION TO ASSURE DRY FILM THICKNESS AT CORNERS AND CREVICES IS EQUIVALENT TO
THAT OF FLAT SURFACES.
4.PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS SIMILAR EXPOSED SURFACES; PAINT
SURFACES BEHIND PERMANENTLY-FIXED EQUIPMENT AND FURNITURE WITH PRIME COAT ONLY.
5.PAINT INTERIOR SURFACES OF DUCTS, WHERE VISIBLE THROUGH REGISTERS OR GRILLES, WITH A FLAT,
NON-SPECULAR BLACK PAINT.
6.PAINT BACK SIDES OF ACCESS PANELS AND REMOVABLE OR HINGED COVERS TO MATCH EXPOSED SURFACES.
7.FINISH DOORS ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES.
8.SAND LIGHTLY BETWEEN EACH SUCCEEDING ENAMEL AND EACH VARNISH COAT.
K.SCHEDULING PAINTING: APPLY FIRST COAT TO SURFACES THAT HAVE BEEN CLEANED, PRETREATED OR PREPARED
FOR PAINTING AS SOON AS PRACTICABLE AFTER PREPARATION.
1.ALLOW TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPER DRYING. DO NOT RECOAT UNTIL PAINT
FEELS FIRM AND DOES NOT DEFORM OR FEEL STICKY UNDER MODERATE THUMB PRESSURE.
L.MINIMUM COATING THICKNESS: APPLY MATERIALS AT NOT LESS THAN MANUFACTURER'S RECOMMENDED
SPREADING RATE, TO ESTABLISH A TOTAL DRY FILM THICKNESS AS RECOMMENDED BY COATING MANUFACTURER.
M.PRIME COATS: APPLY TO ITEMS NOT PREVIOUSLY PRIMED; RECOAT PRIMED AND SEALED SURFACES WHERE THERE IS
EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST COAT.
N.FINISH COATS: PROVIDE EVEN TEXTURE; LEAVE NO LAPS, IRREGULARITY IN TEXTURE, SKID MARKS, OR OTHER
SURFACE IMPERFECTIONS.
O.CLEAN-UP: DURING PROGRESS OF WORK, REMOVE DISCARDED PAINT MATERIALS, RUBBISH, CANS AND RAGS FROM
SITE AT END OF EACH WORK DAY.
1.CLEAN GLASS AND PAINT-SPATTERED SURFACES IMMEDIATELY BY PROPER METHODS OF WASHING AND
SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES.
P.PROTECTION: PROTECT WORK OF OTHER TRADES, WHETHER TO BE PAINTED OR NOT; CORRECT DAMAGE BY
CLEANING, REPAIRING OR REPLACING, AND REPAINTING, AS ACCEPTABLE TO ARCHITECT.
1.PROVIDE "WET PAINT" SIGNS TO PROTECT NEWLY-PAINTED FINISHES.
2.REMOVE TEMPORARY PROTECTIVE WRAPPINGS PROVIDED BY OTHERS FOR PROTECTION OF THEIR WORK,
AFTER COMPLETION OF PAINTING OPERATIONS.
Q.REPAIR: AT COMPLETION OF WORK OF OTHER TRADES, TOUCH-UP AND RESTORE DAMAGED SURFACES OR DEFACED
PAINTED SURFACES.
DIVISION TEN: SPECIALTIES
SECTION 10520 - FIRE EXTINGUISHERS AND CABINETS
A.GENERAL: PROVIDE FIRE EXTINGUISHERS AND CABINETS, ALONG WITH REQUIRED ACCESSORIES AS REQUIRED FOR
A COMPLETE INSTALLATION AND SATISFY THE REQUIREMENTS OF THE GOVERNING AUTHORITIES.
B.STANDARDS: NFPA 10 - STANDARD FOR PORTABLE FIRE EXTINGUISHERS, AND U.L. - FIRE PROTECTION EQUIPMENT
DIRECTORY.
C.SUBMITTALS: PRODUCT DATA.
D.MANUFACTURERS: JL INDUSTRIES, LARSEN'S MANUFACTURING, OR APPROVED EQUAL.
E.FIRE EXTINGUISHERS: COMPLY WITH PRODUCT REQUIREMENTS OF NFPA 10 AND APPLICABLE CODES. PROVIDE
EXTINGUISHERS LABELED BY UNDERWRITERS LABORATORIES, INC. FOR THE PURPOSE SPECIFIED OR INDICATED.
1.MULTI-PURPOSE DRY CHEMICAL TYPE FIRE EXTINGUISHERS - STAINLESS STEEL TANK WITH PRESSURE GAUGE,
CLASS B,C (SIZE 10) FINISH: RED, BAKED ENAMEL.
F.FIRE EXTINGUISHER CABINETS: SEMI-RECESSED TYPE SIZE TO ACCOMMODATE EXTINGUISHER AND ACCESSORIES.
1.FORMED METAL CABINET OF 0.036 INCH MATERIAL WITH FLAT TRIM AT FACE AND RETURNS TO WALL.
2.DOOR WITH 18" THICK CLEAR TEMP. GLAZING, HINGED FOR 180 DEGREE OPENING WITH CONTINUOUS PIANO
TYPE HINGE.
3.EXTERIOR AND INTERIOR OF CABINET TO BE BAKED WHITE ENAMEL FINISH.
G.ACCESSORIES: EXTINGUISHER BRACKETS - FORMED STEEL, CHROME PLATED.
H.INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS.
1.INSTALL CABINETS PLUMB AND LEVEL, SECURED RIGIDLY IN PLACE.
2.VERIFY ALL LOCATIONS WITH LOCAL FIRE MARSHALL PRIOR TO INSTALLATION.
I.SCHEDULE:
1.GENERAL AREAS, HALLWAYS, ETC.: SEMI-RECESSED CABINET WITH MULTI-PURPOSE DRY TYPE EXTINGUISHER
AS LOCATED ON THE DRAWINGS.
2.UTILITY ROOM: WALL MOUNTED EXTINGUISHER BRACKET WITH MULTI-PURPOSE DRY TYPE EXTINGUISHER AS
LOCATED ON THE DRAWINGS.
SECTION 10810 - TOILET ACCESSORIES
A.GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION.
B.CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR
PERSONS WITH DISABILITIES.
C.SUBMITTALS: SUBMIT PRODUCT DATA.
D.MANUFACTURERS: BOBRICK, BRADLEY, OR AMERICAN SPECIALTIES.
E.TYPES: STAINLESS STEEL ACCESSORIES AS INDICATED ON DRAWINGS; PROVIDE GRAB BARS WITH CONCEALED
MOUNTING, SIZES AND SHAPES AS INDICATED AND AS REQUIRED BY APPLICABLE CODES AND REGULATIONS.
F.MATERIALS: STAINLESS STEEL, ASTM A666 / ASTM A269, COMMERCIAL GRADE, TYPE 302/304, NUMBER 4 SATIN
FINISH, SATIN CHROME ACCEPTABLE WHERE STAINLESS STEEL IS NOT AVAILABLE FOR ACCESSORY ITEM SCHEDULED;
GAGES AS STANDARD WITH MANUFACTURER OF SPECIFIED ITEMS.
1.FASTENERS, SCREWS, AND BOLTS: HOT DIP GALVANIZED; AS RECOMMENDED BY ACCESSORY MANUFACTURER
FOR COMPONENT AND SUBSTRATE.
2.CONCEALED SURFACES: PRETREAT AND CLEAN, SPRAY APPLY ONE COAT PRIMER AND BAKED ENAMEL FINISH.
G.FABRICATION: WELD AND GRIND SMOOTH JOINTS OF FABRICATED COMPONENTS; FORM EXPOSED SURFACES FROM
ONE SHEET OF STOCK, FREE OF JOINTS.
1.FABRICATE UNITS WITH TIGHT SEAMS AND JOINTS, EXPOSED EDGES ROLLED; HANG DOORS AND ACCESS
PANELS WITH CONTINUOUS PIANO HINGES; PROVIDE CONCEALED ANCHORAGE WHERE POSSIBLE.
2.PROVIDE STEEL ANCHOR PLATES AND ANCHOR COMPONENTS FOR INSTALLATION.
3.FORM SURFACES FLAT WITHOUT DISTORTION; MAINTAIN FLAT SURFACES WITHOUT SCRATCHES AND WITHOUT
DENTS; FINISH EXPOSED EDGES EASED, FREE OF SHARP EDGES WHERE POTENTIAL EXISTS FOR PHYSICAL
CONTACT.
4.HOT DIP GALVANIZE FERROUS METAL ANCHORS AND FASTENING DEVICES.
5.SHOP ASSEMBLE COMPONENTS; PACKAGE COMPLETE WITH ANCHORS AND FITTINGS.
H.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS.
1.PROVIDE/DELIVER INSERTS, TEMPLATES, ADN ROUGH IN MEASUREMENTS TO SITE FOR A TIMELY INSTALLATION.
2.INSTALL PLUMB AND LEVEL, SECURELY AND RIGIDLY ANCHORED TO SUBSTRATE.
3.MOUNTING HEIGHTS AND LOCATIONS: AS REQUIRED BY ACCESSIBILITY REGULATIONS AND AS INDICATED ON
THE DRAWINGS.
DIVISION ELEVEN: EQUIPMENT (NOT USED)
DIVISION TWELVE: FURNISHINGS (NOT USED)
DIVISION THIRTEEN: SPECIAL CONSTRUCTION (NOT USED)
DIVISION FOURTEEN: CONVEYING SYSTEMS (NOT USED)
DIVISION FIFTEEN: MECHANICAL
REFER TO MECHANICAL DRAWINGS.
DIVISION SIXTEEN: ELECTRICAL
REFER TO MECHANICAL DRAWINGS.
SHEET TITLE:
SEAL/SIGNATURE:
ISSUES AND REVISIONS:
PROJECT NO.:
DRAWN BY:
CHECKED BY:
PROJECT:
MERCHANT'S SQUARE
2316 EAST 116TH STREET
CARMEL, INDIANA 46032
12039
RLO
SAW / MCF
SALON LOFTS PROJECT NO.:
ININD-002
2145 Ford Parkway, Suite 301
Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com
SALON LOFTS
CLIENT REVIEW SET 12.07.2012
PERMIT ISSUE 12.10.2012
IA N AIND
I T E C T
*
A
RCH
*
IFC.KRAM N
A
M
ENN
N
SPECIFICATIONS
SP.3