Loading...
HomeMy WebLinkAbout12.10.12 SL Merchant_s Square- Permit Issue Arch.pdfXXX X XXX X X XXX XXX X Detail Reference Sheet Number Elevation Reference Drawing Number Section Reference Sheet Number Door / Glazing Opening Mark Key Note Grid Number OFS OUTSIDE FACE OF STUDS OH DR OVERHEAD DOOR OPENINGOPNG ORD OVERFLOW ROOF DRAIN PAR PARTIALPART PCC PRECAST CONCRETE PLASTIC LAMINATEPLAM PLYWD PLYWOOD PRCST PRECAST PREFINISHPREFIN PRELIM PRELIMINARY PRKG PARKING PAINT/PRESSURE TREATEDPT PTD PAPER TOWEL DISPENSER PTN PARTITION QT QUARRY TILE QTB QUARRY TILE BASE R RADIUS/RISER RCP REFLECTED CEILING PLAN RD ROOF DRAIN REBAR REINFORCING STEEL BARS RECESSEDREC REV REVISIONS / REVERSE RM ROW RIGHT OF WAY RTU ROOF TOP UNIT TD TRENCH DRAIN TEL TELEPHONE THRU THROUGH TO TOP OF TO FDN TOP OF FOUNDATION TOP OF BEAMTOB TOF TOP OF FLOOR/FOOTING TOJ TOM TOP TOS TOT TOW TPD TPH TRTD TREATED TOILET PAPER HOLDER TOILET PAPER DISPENSER TOP OF WALL TOP OF TRUSS TOP OF SLAB/STEEL TOP OF PARAPET TOP OF MASONRY TOP OF JOIST SUSPENDED CEILINGSUSP CLG STRUCT STRUCTURAL STANDARDSTD SST STAINLESS STEEL SPRINKLERSPKLR SPEC SPECIFICATION SOUND INSULATIONSND INS SND SANITARY NAPKIN DISPENSER SIMILARSIM SHTHG SHEATHING SQUARE FOOTSF SEP SEPARATE SECTIONSECT SD SHOP DRAWINIGS/SOAP DISPENSER SOLID CORE WOOD DOORSCWD SCP SCUPPER SCHEDULESCHED ROOM PARALLEL/PARAPET TYP TYPICAL UNLESS NOTED OTHERWISEUNO UR URINAL VANITYVAN VAR VARIES VINYL BASEVB VCT VINYL COMPOSITION TILE VERTICALVERT VRFY VERIFY VINYL WALL COVERINGVWC W/WITH WITHOUTW/O WC WALL COVERING/WATER CLOSET WD WDW WINDOW WOOD Abbreviations used in referring to standards that apply to the work include, but are not necessarily limited to, the following: AA Aluminum Associate, Inc. AAMA Architectural Aluminum Manufacturer's Assoc. American Concrete InstituteACI AISC American Institute of Steel Construction American National Standards InstituteANSI ASTM American Society for Testing Materials AWS American Welding Society CRSI Concrete Reinforcing Steel Institute National Association of Architectural Metal Manufacturer's NAAMM NFPA National Fire Protection Association X DRAWING SCHEDULE A0.0 PROJECT INFORMATION A0.1 OPENING SCHEDULES A2.1 TOILET ROOM PLAN, ELEVATIONS & ACCESSIBILITYA2.2 FINISH FLOOR PLAN INTERIOR ELEVATIONS A2.3 A4.1 A4.0 DOOR & SIDELIGHT ELEVATIONS & DETAILS A0.2 FINISH SCHEDULES A0.3 RESPONSIBILITY SCHEDULE A1.0 DEMOLITION & FLOOR TRENCHING PLAN FLOOR PLAN ISSUED FOR PRELIMINARY REVIEW ISSUED FOR PERMIT/CONSTRUCTION ISSUED FOR REFERENCE ONLY ISSUED FOR CONSTRUCTION W/ REVISED INFO. CONSTRUCTION DETAILS ARCHITECTURAL CASEWORK DETAILS ARCHITECTURAL DETAILS SPECIFICATIONS FURNITURE PLAN REFLECTED CEILING PLANA3.0 INTERIOR ELEVATIONS A6.1 A6.2 A6.3 SP.1 SPECIFICATIONSSP.2 SPECIFICATIONSSP.3 CODE SYNOPSIS GENERAL NOTES 1.THE COMPLETE CONSTRUCTION DOCUMENT SET IS INCLUSIVE OF THE DRAWING SHEETS LISTED IN THE DRAWINGSCHEDULE, THE INVITATION TO BID PACKAGE, AND ALL LANDLORD CONSTRUCTION REQUIREMENTS. 2.THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ANDSHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC., SHALL BEIMMEDIATELY REPORTED TO THE OWNER'S REPRESENTATIVE & ARCHITECT FOR CLARIFICATION PRIOR TO THEPERFORMANCE OF ANY WORK IN QUESTION. THE CONTRACTOR COMMENCING WORK ACCEPTS THE CONDITIONSOF THE PROJECT AND THE COMPLETENESS OF THE CONSTRUCTION DOCUMENTS. NO EXTRAS SHALL BE ALLOWEDFOR DISCREPANCIES AFTER THE WORK HAS BEGUN, EXCEPT WHERE THE CONDITION COULD NOT HAVE BEENDISCERNABLE WITHOUT THE REMOVAL OF THE CONCEALING CONDITION. 3.GENERAL CONTRACTOR AND ITS SUBCONTRACTORS (INCLUDING BUT NOT LIMITED TO HVAC, ELECTRICAL,PLUMBING, SPRINKLERS, ETC.) SHALL BE RESPONSIBLE FOR ALL PERMITS, INSPECTIONS AND ASSOCIATED FEES ASREQUIRED TO COMPLETE THE WORK. 4.ALL WORK SHALL BE IN COMPLIANCE WITH THE PROVISIONS OF THE 'AMERICANS WITH DISABILITIES ACT' (ADA)AND ICC/ANSI A117.1-2003. 5.WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT INCONTRACT, HE SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS. 6.THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIREPROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 7.DURING ALL PHASES OF WORK, DO NOT DISTURB THE DELIVERIES AND FUNCTIONS OF ADJACENT ANDNEIGHBORING TENANTS. NOTIFY BY LETTER TO ADJACENT TENANTS OF ANYTHING THAT MAY HINDER THEIRBUSINESS OPERATIONS PRIOR TO START OF CONSTRUCTION. 8.'TYP.' SHOULD MEAN THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.UNLESS OTHERWISE NOTED, DETAILS ARE USUALLY KEYED & NOTED 'TYP.' ONLY ONCE WHEN THEY FIRST OCCUR. 9.DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. THECONTRACTOR SHALL ALERT THE ARCHITECT OF ANY GROSS INCONSISTENCIES BETWEEN SCALED DIMENSIONSAND WRITTEN DIMENSIONS. 10.ARCHITECTURAL DRAWINGS TAKE PRECEDENCE OVER OTHER DRAWINGS FOR LAYOUT DIMENSIONS ANDNUMBER OF ITEMS PROVIDED. UPON DISCOVERY OF DISCREPANCIES BETWEEN ARCHITECTURAL DRAWINGS ANDENGINEERING DRAWINGS, THE GENERAL CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVEIMMEDIATELY. 11.HORIZONTAL DIMENSIONS ARE SHOWN FROM THE FINISHED FACE OF CONSTRUCTION, UNLESS NOTEDOTHERWISE. 12.VERTICAL DIMENSIONS ARE FROM THE TOP OF FLOOR FINISH, ESTABLISHED BY THE CONTRACTOR SUBJECT TOTHE APPROVAL OF THE OWNER OR ARCHITECT, UNLESS NOTED OTHERWISE. 13.DIMENSIONS ARE NOT ADJUSTABLE WITHOUT THE APPROVAL OF THE OWNER'S REPRESENTATIVE OR THEARCHITECT UNLESS NOTED +/-. 14.DO NOT SUBSTITUTE, REVISE, OR CHANGE THE WORK WITHOUT THE WRITTEN CONSENT OF THE OWNER'SPROJECT REPRESENTATIVE. 15.COORDINATE ALL WORK AS REQUIRED WITH THE LANDLORD'S REPRESENTATIVE INCLUDING COMPLIANCE WITH"LANDLORDS WORKING RULES", LOCAL NOISE ORDINANCES, THE USE OF ELEVATORS, TEMPORARY STORAGE,LOADING DOCKS, BUILDING KEYING SYSTEMS, ETC. PROVIDE NECESSARY BARRICADES, LIGHTING, SIGNAGE, ANDGUARDRAILS AS REQUIRED BY OWNER AND/OR APPLICABLE REGULATORY ADVISORY FOR THE PROTECTION OFBUILDING OCCUPANTS, WORKERS AND PEDESTRIANS. 16.GENERAL CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING,RESTORING, REPAIRING AND THE LIKE NECESSARY TO COMPLETE THE WORK AND RESTORE ANY DAMAGEDSURFACES RESULTING FROM THE WORK TO THEIR ORIGINAL CONDITION. ALL ROOF PATCHING SHALL RETURNAREA TO "LIKE NEW" CONDITION. PRIOR TO BIDDING, G.C. TO VERIFY ANY ROOF WARRANTIES WITH LANDLORDAND INCLUDE IN CONTRACT. G.C. TO COORDINATE ALL MEANS AND METHODS OF DEMOLITION, SAW CUTTING,CORING AND PATCHING LANDLORD CONSTRUCTION AND MATERIALS WITH LANDLORD PRIOR TO CONSTRUCTION. 17.IN THE EVENT HAZARDOUS MATERIALS ARE ENCOUNTERED ON THE PREMISES DURING THE EXECUTION OF THEWORK, NOTIFY THE OWNER'S REPRESENTATIVE & LANDLORD IMMEDIATELY BEFORE PROCEEDING WITH WORK. 18.CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2-A/10BCWITHIN 75' TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING DURING CONSTRUCTION. 19.PATCH AND REPAIR ALL FIREPROOFING DAMAGED OR REMOVED DURING THE PERFORMANCE OF THE WORK. 20.EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETIONOF HIS WORK ON A DAILY BASIS. ALL WASTE, RUBBISH AND EXCESS MATERIALS SHALL BE REMOVED FROM THESITE PROMPTLY. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL & DISPOSAL OF ALL TRASH,INCLUDING OWNER-FURNISHED ITEMS & TRASH GENERATED BY OWNER'S CONTRACTORS FOR THE DURATION OFTHE PROJECT. 21.IT IS THE RESPONSIBILITY OF THE G.C. TO OBTAIN LANDLORD/CITY APPROVED DRAWINGS PRIOR TOCONSTRUCTION. LANDLORD/CITY APPROVED DRAWINGS SHALL BE RECEIVED FULLY BY THE G.C. PRIOR TOCONSTRUCTION AND ANY PROVISIONS, ADJUSTMENTS OR MODIFICATIONS AS REQ'D. BY LANDLORD/CITY SHALLBE COORDINATED WITH THE TENANT/LANDLORD/CITY PRIOR TO CONSTRUCTION IF NOT CLEARLY INDICATED INTHE CONSTRUCTION DRAWINGS. LANDLORD/CITY APPROVED DRAWINGS SHALL BE AVAILABLE ON SITE FROMSTART OF CONSTRUCTION TO COMPLETION AND FINAL PUNCH. 22.THE CONTRACTOR WILL OBTAIN A CURRENT COPY OF THE LANDLORD CONSTRUCTION CRITERIA FROM THELANDLORD & COORDINATE WITH LANDLORD FOR USE OF ALL REQUIRED SUBCONTRACTORS AND CONSULTANTS. 23.CONTRACTOR TO VERIFY INTEGRITY OF EXISTING CONDITIONS, INCLUDING ALL STRUCTURAL ELEMENTS, AFTERCOMPLETION OF DEMOLITION AND NOTIFY THE OWNER'S AND LANDLORD'S REPRESENTATIVES IMMEDIATELY OFANY DAMAGES AND/OR INSTABILITY. 24.GENERAL CONTRACTOR SHALL INSPECT ALL LANDLORD'S WORK TO ENSURE COMPLIANCE WITH LANDLORDSWORK LETTER AND SHEET A1.0 OF THIS DOCUMENT SET. ALL LANDLORDS WORK SHALL BE IN FULL CODECOMPLIANCE AND GOOD WORKMAN LIKE ORDER - GENERAL CONTRACTOR SHALL ACCEPT RESPONSIBILITY FORALL WORK AT TIME OF LANDLORD TURN OVER FOR TENANT'S CONSTRUCTION. 25.SAFETY MEASURES: AT ALL TIMES THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THECONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF THE PERSONS AND PROPERTY AND FOR ALL INDEPENDENTENGINEERING REVIEWS OF THESE CONDITIONS. THE ARCHITECT'S, ENGINEER'S AND/OR TENANT'S JOB SITEREVIEW IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES.26.ALL DRILLING, WELDING, OR OTHER ATTACHMENT TO THE STRUCTURAL SYSTEM MUST BE APPROVED BY THELANDLORD IN WRITING BEFORE WORK IS BEGUN. THE CONTRACTOR TO COORDINATE WITH LANDLORD. 27.ADEQUATE FIRE RETARDANT BLOCKING, BRACING, BACKING AND/OR ADDITIONAL STUDS MUST BE PROVIDED BYTHE CONTRACTOR TO SUPPORT ANY STORE FIXTURES, SHELVES, MILLWORK, OR DECORATIVE ELEMENTS, TRIMFASTENED TO THE WALLS. THE CONTRACTOR TO COORDINATE WITH FIXTURE SUPPLIER AS NECESSARY. 28.THE USE OF WOOD OR OTHER COMBUSTIBLE MATERIALS ABOVE THE CEILING IS PROHIBITED, UNLESS NOTEDOTHERWISE. 29.GENERAL CONTRACTOR SHALL HAVE OBTAINED ALL REGULAR INSPECTIONS WITH AT LEAST A TEMPORARY'CERTIFICATE OF OCCUPANCY' IN POSSESSION PRIOR TO THE CONSTRUCTION PUNCH DATE. 30.GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO HAVE THE ENTIRE PROJECT AREA FINAL CLEANED (SPOTLESS)AT THE TIME OF TURNOVER TO THE OWNER. ABBRV TERM ABBRV TERM ACC ACCESSIBLE ACOUSTICAL CEILING TILEACT ADA AMERICANS WITH DISABILITIES ACT ADDITIONALADDL ADDM ADDENDUM ADJACENTADJ AFF ABOVE FINISHED FLOOR ALTERNATE ALUMINUMALUM ALT BLDG BUILDING BITUMINOUSBITUM BRG BEARING BASEMENTBSMT BTWN BETWEEN CABINETCAB CL CENTER LINE CLASS CLASSIFICATION CLG CEILING CLG HT CEILING HEIGHT CLR CLEAR CMU CONCRETE MASONRY UNIT COL CONC CONSTR COORD COORDINATE CONSTRUCTION CONCRETE COLUMN CPT CARPET CERAMIC TILECT DEMOLITIONDEMO DET DETAIL DRINKING FOUNTAINDF DIA DIAMETER DIMENSIONDIM DIR DIRECTION DOORDR DS DOWNSPOUT DISHWASHERDW EA EACH EXTERIOR INSULATION AND FINISH SYSTEMEIFS EXPANSION JOINT ELEVATIONEL EJ ELEV ELEVATOR EQUALEQ EQUIP ESMT EASEMENT EQUIPMENT EXIST EXISTING FACE BRICKFC BRK FD FLOOR DRAIN FDTN FOUNDATION FF EL FINISH FLOOR ELEVATION FINISHFIN FIN FLR FINISH FLOOR FIXT FIXTURE FLR FLOOR FLUOR FLUORESCENT FIBERGLASS REINFORCED PLASTICFRP FT FEET FOOTINGFTG FURG FURRING GALVANIZEDGALV GB GRAB BAR GENERAL CONTRACTORGC GL GLASS GLZ GLAZING GYP BD GYPSUM BOARD HC HANDICAP/HOLLOW CORE HOLLOW CORE WOOD DOORHCWD HDW HARDWARE HOLLOW METAL DOOR AND FRAMEHMDF HT HEIGHT HEATING, VENTILATING, & AIR CONDITIONINGHVAC ID INSIDE DIAMETER/INSIDE DIMENSION INSUL INT INTERIOR INSULATION LAMINATE ANGLEL LAM LAVATORYLAV LDG LANDING LTG LIGHTING MATL MATERIAL MFR MANUFACTURER MFR RECMANUFACTURER'S RECOMMENDATION MIN MINIMUM MASONRY OPENINGMO MTL METAL NUMBERNO NTS NOT TO SCALE ON CENTEROC OD OUTSIDE DIAMETER/OUTSIDE DIMENSION ABBREVIATIONS SYMBOLS Datum Point XXX Owner Supplied Item Tag X Revision Number XXX Finish Key X X ABBRV TERM A2.0 A2.4 DIMENSION FLOOR PLAN A6.0 MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 SALON LOFTS PROJECT TEAM FINN DANIELS ARCHITECTS 2145 FORD PARKWAY, SUITE 301 ST. PAUL, MINNESOTA 55116 651.690.5525 (VOICE) 651.690.5545 (FACSIMILE) CONTACT: SCOTT WIESTLING EMAIL: swiestling@finn-daniels.com SALON LOFTS 100 SOUTH 4TH STREET #100 COLUMBUS, OHIO 43215 614.227.0530 (VOICE) 614.227.3280 (FACSIMILE) CONTACT: TANAYA CANDELLA EMAIL: tcandella@salonloftscorp.com TENANT: ARCHITECT: RAMCO-GERSHENSON PROPERTIES 31500 NORTHWESTERN HIGHWAY #300 FARMINGTON HILLS, MICHIGAN 48334 614.481.0353 (VOICE) CONTACT: GILLI ZOFAN EMAIL: gzofan@rgpt.com BUILDING OWNER / LANDLORD: BUILDING/ ZONING DEPTS.: EMANUELSON-PODAS, INC. 10401 BREN ROAD EAST MINNETONKA, MINNESOTA 55343 952.930.0050 (VOICE) 952.930.0777 (FACSIMILE) CONTACT: MATT COLEMAN EMAIL: mcoleman@epinc.net MEP ENGINEER: VICINITY MAP N BUILDING KEY PLAN N CITY OF CARMEL 1 CIVIC SQUARE CARMEL, INDIANA 46032 317.571.2400 (VOICE) ARCHITECTURAL E1.1 LIGHTING PLAN ELECTRICAL E2.1 POWER PLAN E3.1 E4.1 ELECTRICAL SPECIFICATIONS M1.1 MECHANICAL PLAN MECHANICAL M2.1 PLUMBING PLAN - SANITARY & VENT M2.2 PLUMBING PLAN - DOMESTIC WATER M3.1 PLUMBING RISER DIAGRAMS M4.1 MECHANICAL DETAILS AND SCHEDULES M5.1 MECHANICAL NOTES M5.2 MECHANICAL SPECIFICATIONS 12 . 0 7 . 1 2 CL I E N T R E V I E W SE T SALON LOFTS MERCHANT'S SQUARE 4,906 SQUARE FEET 12 . 1 0 . 1 2 PE R M I T I S S U E A1.1 BUILDING SHELL MODIFICATIONS PLAN & DETAILS SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 PROJECT INFORMATION A0.0 A1.2 EXTERIOR ELEVATIONS ELECTRICAL SCHEDULES AND RISER ARCHITECTURAL DETAILSA6.4 SMITH/ROBERTS & ASSOCIATES, INC. 6501 BLUFF ROAD INDIANAPOLIS, INDIANA 46217 317.951.1043 (VOICE) 317.951.2160 (FACSIMILE) CONTACT: JEFF LUNSFORD EMAIL: jlunsford@sraeng.com STRUCTURAL ENGINEER: S1.0 STRUCTURAL STRUCTURAL PLAN & DETAILS Required Provided PLUMBING FIXTURES: A.NUMBER FIXTURES REQUIRED (IBC 2902.1) Based on 50 Occupants - B Occupancy - 25 Female Occupants - 25 Male Occupants (a) BOTTLED WATER SHALL BE PROVIDED IN EACH LOFT FOR EMPLOYEES AND CUSTOMERS. Fixture Water Closets (1 Per 25 Occupants) Lavatories (1 Per 40 Occupants) Drinking Fountain (1 Per 100 Occupants) Service Sink Men Women 1 1 1 1 1 1 1 1(a) SIGNAGE: A.SIGNAGE IS NOT WITHIN THE SCOPE OF THIS PERMIT. SUBMIT DRAWINGS TO LOCAL JURISDICTION FOR REVIEW AND APPROVAL IN ACCORDANCE WITH LOCAL CODES AND ORDINANCES PRIOR TO INSTALLATION. A.BUILDING OCCUPANCY USE GROUP: B - BUSINESS B.BUILDING CONSTRUCTION TYPE: TYPE II-B (EXISTING) C.SALON LOFTS OCCUPANT LOAD: 50 (BASED ON 1 OCC. PER 100 S.F. @ 4,906 S.F.) D.QUANTITY OF EXITS REQUIRED: 2 E.QUANTITY OF EXITS PROVIDED: 2 F.SPRINKLER SYSTEM: NO G.FIRE ALARM SYSTEM REQUIRED: NO (PER IBC 907.2.2 FOR GROUP B OCC. < 300 OCC.) H.SEISMIC ZONE: N/A A.INDIANA BUILDING CODE (IBC)2008 B.INDIANA FIRE CODE (IFC)2008 C.INDIANA MECHANICAL CODE (IMC)2008 D.INDIANA PLUMBING CODE (IPC)1999 E.INDIANA ELECTRICAL CODE (IEC)2009 F.ICC A117.1 ACCESSIBLE & USABLE BUILDINGS & FACILITIES 2003 G.CITY OF CARMEL CODE CURRENT APPLICABLE CODES: BUILDING CLASSIFICATION: Men Women 1 1 1 1 A4.2 INTERIOR ELEVATIONS HOLLOW METAL (1 1/4" NARROW PROFILE FRAMES) PAINT 8' - 0 " DO O R 1 1/4" 1 1 / 4 " 3'-0" DOOR 3 P7 3'-1 1/2" R.O. 8' - 0 3 / 4 " R. O . FLUSH DOOR (SWING)CS.C. WOOD (STAIN/SEAL) PLAIN SLICED RED OAK W/ CUSTOM STAIN TO MATCH W/ GLASS PANEL 1/4" TEMP. CLEAR GLAZING 10 " 6" 6"6" DFLUSH DOOR (SWING) S.C. WOOD (STAIN/SEAL) PLAIN SLICED RED OAK W/ CUSTOM STAIN TO MATCH A6.0 9sim 2' - 0 " 3' - 7 " 5" SOLID TOP RAIL LOCK BLOCK FOR DOOR HANDLE 5" SOLID BOTTOM RAIL FLUSH DOOR (SLIDING) H.C. WOOD (STAIN/SEAL) PLAIN SLICED RED OAK W/ CUSTOM STAIN TO MATCH A B PL-4 PL-4 PL-4 2 ALUM. GLAZING SYSTEM 2" x 4 1/2" CLEAR ANODIZED ALUMINUM FRAME W/ 1/4" CLEAR TEMP. GLAZING 8' - 2 " 7' - 1 0 " 2" 2" 6'-0"± R.O. (VERIFY) 3'-0" DOOR 1'-6" 2"2" 1'-6" W-1 1 3/4" x 4 1/2" DARK BRONZE ANODIZED ALUM. FRAME W/ 1/8" TEMPERED TINTED SAFETY GLAZING TO MATCH EXISTING ALUM. GLAZING SYSTEM CAT 5/6 CABLE PoE SWITCH OR MIDSPAN INJECTOR POWERED ELECTRIC LOCK FIRE ALARM SYSTEM RELAY WIEGAND OR PIN CARD READER 18 AWG 2 COND. 18 AWG 6 COND. WIEGAND OR PIN CARD READER 18 AWG 6 COND. FIRE ALARM SYSTEM RELAY ELECTRIC LOCK 18 AWG 2 COND. ALUMINUM / GLAZING ENTRY ALUMINUM FRAME MEDIUM STILE- DARK BRONZE ANODIZED W/ GLASS PANEL 1" INSULATED TEMP. CLEAR GLAZING 10 " 8'-8"± R.O. (VERIFY) 3'-0" DOOR2" 2'-10" 2"2" 2'-10" 2" 9' - 0 " ± R . O . ( V E R I F Y ) 2' - 6 1 / 4 " 1 3 / 4 " 4' - 2 " 1' - 8 1 / 2 " 1 3 / 4 " 1 ALUM. GLAZING SYSTEM 2" x 4 1/2" DARK BRONZE ANODIZED ALUMINUM FRAME W/ 1" INSULATED TINTED GLAZING TO MATCH EXISTING (TEMPERED WHERE REQ'D. BY CODE) 3'-3 1/2" (VERIFY) 2'-8 1/2" EXISTING STOREFRONT TO REMAIN EXISTING STOREFRONT TO REMAIN 1 3/4"1 3/4"± EXISTING MULLION 1 3/4"± EXISTING MULLION 9' - 0 " R . O . (V E R I F Y ) 1 3 / 4 " 1 3 / 4 " 6' - 0 1 / 2 " VE R I F Y 2' - 6 1 / 4 " 5' - 1 1 1 / 4 " R . O . 2' - 8 3 / 4 " VF Y . 2" 5' - 7 1 / 4 " W-2 ALUM. GLAZING SYSTEM 2" 2" 6'-0"± M.O. 2"EQ.EQ.2" W-3 2" x 4 1/2" DARK BRONZE ANODIZED ALUM. FRAME W/ 1" INSUL. TINTED GLZ. TO MATCH EXIST. (TEMP. WHERE REQ'D. BY CODE) ALUM. GLAZING SYSTEM 2" x 4 1/2" DARK BRONZE ANODIZED ALUM. FRAME W/ 1" INSUL. TINTED GLZ. TO MATCH EXIST. (TEMP. WHERE REQ'D. BY CODE) 4'-0"± M.O. 2"2" 6' - 3 3 / 4 " R . O . 2' - 8 3 / 4 " VF Y . 2" 5' - 1 1 3 / 4 " 2" 7' - 0 " DO O R HARDWARE GROUPS 1.ALL DOOR HARDWARE SHALL COMPLY WITH FEDERAL AND STATE ACCESSIBILITY REQUIREMENTS INCLUDING THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. 2.ALL EXIT DOORS TO BE OPENABLE FROM INSIDE WITHOUT USE OF A KEY, SPECIAL KNOWLEDGE OR EFFORT. 3.THE MAXIMUM FORCE REQUIRED TO OPERATE ANY DOOR SHALL COMPLY AS FOLLOWS: A. INTERIOR DOORS = 5 LBS. B. EXTERIOR DOORS = 8.5 LBS. C. FIRE-RATED DOORS = MINIMUM ALLOWABLE BY APPROPRIATE ADMINISTRATIVE AUTHORITY. 4.WHEN EXISTING, G.C. TO REVIEW EXISTING HARDWARE CONDITIONS & MAKE RECOMMENDATIONS ON REPLACEMENTS AS REQ'D. PRIOR TO CONSTRUCTION. 5.REFURBISH ALL EXISTING DOORS LISTED AS "TO REMAIN" TO "LIKE NEW" CONDITION. 6.PROVIDE (1) SET SMOKE GASKETING @ ALL RATED DOOR ASSEMBLIES. 7.GENERAL CONTRACTOR SHALL COORDINATE ALL HARDWARE GROUPS AND FINISHES W/ OWNER PRIOR TO ORDERING. 8.COORDINATE THE KEYING OF LOCKS WITH OWNER. 9.HARDWARE SHALL INCLUDE ALL NECESSARY ACCESSORIES SUCH AS SCREWS, BOLTS, NUTS, ANCHORS, TOGGLE BOLTS, AND OTHER FASTENERS AS REQUIRED FOR A COMPLETE INSTALLATION. 10.INSTALL HARDWARE PER MANUFACTURER'S RECOMMENDATIONS. 11.ALL DOORS WHICH OPEN TOWARDS AN ADJACENT WALL SHALL BE SUPPLIED WITH WALL, DOOR, OR OVERHEAD STOPS. 12.CONTRACTOR SHALL VERIFY ALL DOOR HARDWARE PER SPECIFIC CODE REQUIREMENTS FOR THIS FACILITY. 13.CONTRACTOR SHALL COORDINATE THE INSTALLING OF ALL CYLINDER LOCKS W/ OWNER. 14.PROVIDE HARDWARE SUBMITTAL TO ARCHITECT & TENANT FOR APPROVAL PRIOR TO CONSTRUCTION. 15.ALL HARDWARE ON ALUMINUM DOORS & FRAMES SHALL BE FINISHED TO MATCH DOOR & FRAME FINISH, TYP. U.N.O. 16. INTERIOR DOOR HARDWARE SHALL BE US26D FINISH, TYPICALLY, U.N.O. '1' VESTIBULE - SUPPLIED/INSTALLED BY G.C. (U.N.O.) (3) -HINGES (4 12"x4 12") (1) -CLOSER - LCN 4000 SERIES - MATCH DOOR COLOR (1) -ALUMINUM THRESHOLD - SEE 2/A2.4 (1) -OFFSET PULL - MATCH DOOR COLOR (1) - PUSH BAR - MATCH DOOR COLOR (1) -CYLINDER - MUST ACCEPT SMALL FORMAT INTERCHANGEABLE CORES (1) -SMALL FORMAT INTERCHANGEABLE CORE SUPPLIED BY SALON LOFTS (1) -WEATHERSTRIPPING (1) -"DOOR TO REMAIN UNLOCKED DURING STORE OPERATION" SIGNAGE (1) -ACCESS CONTROL HARDWARE PACKAGE BY SALON LOFTS VENDOR. SEE ACCESS CONTROL HARDWARE SPEC. BELOW FOR ADDITIONAL INFORMATION. '2' VESTIBULE - SUPPLIED/INSTALLED BY G.C. (U.N.O.) (4) -HINGES (4 12"x4 12") (1) -PULL - SUPPLIED BY S.L./INSTALLED BY G.C. (T.O. HANDLE @ 5'-6" A.F.F.) (1) - PUSH PLATE - IVES 8200 (US32D) (1) - CLOSER - LCN 4000 SERIES (1) -FLOOR STOP - IVES FS448 US26D (2) - KICK PLATE - IVES 8400 PA28 8"x34" '3' TOILET (4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D (1) -PRIVACY LOCKSET - SCHLAGE S40 (JUP) 626 (1) -CLOSER - HAGER 5200 (AL) (1) -A.D.A. ACCESSIBLE 'UNISEX' RESTROOM SIGNAGE. (MATTE BLACK W/ WHITE LETTERS - 6"W. X 9"H.) (2) -COAT HOOKS (MOUNTED VERTICALLY - 1 @ 4'-0" A.F.F. & 1 @ 5'-6" A.F.F., CENTER BOTH HORIZ. ON INSIDE FACE OF DOOR) (1) -WALL STOP - HAGER 236W (32D) '4' UTILITY (4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D (1) -PASSAGE LATCHSET - SCHLAGE S10D (JUP) 626 (1) -CLOSER - HAGER 5200 (AL) (1) - WALL STOP - HAGER 236W (32D) '5' LOFT ENTRY (1) -HEAVY DUTY TRACK W/ BRACKETS (8) -SET TRACK MOUNT 5/8" SPACERS (4) -5" MIN. L. STAINLESS STL. LAG SCREWS (2) -HEAVY DUTY DOOR HANGERS (2) -BEARING ASSEMBLIES (1) -PULL (T.O. HANDLE @ 5'-6" A.F.F.) (2) -BOTTOM GUIDE #1705 (SEE 9sim./A6.0) (1) -DEADBOLT LOCK (KEYED HALLWAY SIDE) SCHLAGE B561BD (626) (1) - HARDWOOD SILL GUIDE TRACK W/ INTEGRAL STRIKE '6' LOFT ENTRY (4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D (1) -ENTRY LOCKSET - SCHLAGE S51 (JUP) 626 (1) -WALL STOP - HAGER 236W (32D) (*) -SMOKE/SOUND GASKETING AT SPA LOFT ONLY (*) - DOOR BOTTOM SWEEP AT SPA LOFT ONLY PEMKO ALUMINUM WITH BLACK NEOPRENE INSERT OR EQUAL '7' SIDE DOOR - SUPPLIED/INSTALLED BY G.C. (U.N.O.) (3) -(E) HINGES (1) -(E) CLOSER (1) -(N) ALUMINUM THRESHOLD - SEE 2/A2.4 (1) - (E) PULL (1) -(E) PUSH BAR (1) -(N) CYLINDER - MUST ACCEPT SMALL FORMAT INTERCHANGEABLE CORES (1) -(N) SMALL FORMAT INTERCHANGEABLE CORE SUPPLIED BY SALON LOFTS (1) - (E) SET OF WEATHERSTRIPPING (1) -(N) "DOOR TO REMAIN UNLOCKED DURING STORE OPERATION" SIGNAGE (1) -(N) ACCESS CONTROL HARDWARE PACKAGE BY SALON LOFTS VENDOR. SEE ACCESS CONTROL HARDWARE SPEC. BELOW FOR ADDITIONAL INFORMATION. '8' SPA VESTIBULE ENTRY (4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D (1) -PASSAGE LATCHSET - SCHLAGE S10D (JUP) 626 (1) -CLOSER - HAGER 5200 (AL) (1) -WALL STOP - HAGER 236W (32D) (1) -SMOKE/SOUND GASKETING (1) - DOOR BOTTOM SWEEP PEMKO ALUMINUM WITH BLACK NEOPRENE INSERT OR EQUAL '9' VACANT LEASE SPACE - SUPPLIED/INSTALLED BY G.C. (4) -HINGES - HAGER BB1279 (4 12"x4 12") 26D (1) - CLOSER - HAGER 5200 (AL) (1) -ENTRY LOCKSET - SCHLAGE S51 (JUP) 626 (1) -WALL STOP - HAGER 236W (32D) '10' COMMON DOOR - SUPPLIED/INSTALLED BY G.C. (U.N.O.) (3) -(E) HINGES (1) -(E) CLOSER (1) -(E) ALUMINUM THRESHOLD (1) - (E) SMOKE GASKETING (1) -(N) STOREROOM LOCKSET SCHLAGE ND96PD (JUP)626 (1) -(N) SMALL FORMAT INTERCHANGEABLE CORE SUPPLIED BY SALON LOFTS [NOTE: FINAL HARDWARE PACKAGE TO BE DETERMINED BY MANUF./SUPPLIER BASED ON DESIGN DETAILS THESE DWGS.] DOOR OPENING & HARDWARE NOTES DOOR MATERIAL MARK LOCATION SIZE (NOMINAL) width x height x thickness DOOR TYPE FRAME MATERIAL RATING DETAIL NUMBER HEAD JAMB SILL REMARKS / NOTESHDWARE GROUP FRAME TYPE NOTES: 1.SEE SPECIFICATIONS AND SHEETS A6.0 & A6.1 FOR DOOR DETAILS. DOOR SCHEDULE ACCESS CONTROL HARDWARE SPECIFICATIONS DOOR TYPESGENERAL DOOR & FRAME NOTES SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N FRAME TYPES 101A VESTIBULE '101'3'-0" x 7'-0"ALUM./GLAZING ALUM.-A 1 -------1 101B VESTIBULE '101'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING ALUM.-B 2 -------2 111 UTILITY '111'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 4 -------3 01 LOFT '01'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 6 -------3 108 TOILET '108'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 3 -------3 1.TENANT'S GENERAL CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND ALTER SPECIFICATIONS AS REQUIRED TO MATCH EXISTING BUILDING SHELL WHEN INDICATED. CONTACT TENANT & ARCHITECT IMMEDIATELY TO NOTIFY. 2.SEE SPECIFICATIONS FOR STOREFRONT GLAZING SYSTEM & GLASS SPECIFICATIONS. 3.COORDINATE HOLLOW METAL FRAME WIDTH REQUIRED WITH ACTUAL WALL TYPE THICKNESS OF SCHEDULED WALL TYPE. 4.VERIFY ALL ROUGH OPENING SIZES WITH DOOR/FRAME MANUFACTURER. 5.INSTALL ALL FRAMES AND DOORS PER MANUFACTURERS DETAILS & RECOMMENDATIONS. 6.SLIDING DOORS TO PROVIDE 2'-10" (34") MIN. CLEAR WIDTH IN THE FULL OPEN POSITION. 7.PROVIDE SHOP DRAWINGS FOR APPROVAL PRIOR TO SYSTEM FABRICATION, INCLUDING CONTACT INFORMATION FOR QUESTIONS. 8.ALL FRAMES ARE SHOWN FROM EXTERIOR, TYP. 9.ALUMINUM GLAZING SYSTEM COLOR TO MATCH EXISTING STOREFRONT GLAZING SYSTEMS (VERIFY IN FIELD). 10.HORIZONTAL GLAZING MULLIONS TO BE PROVIDED AND INSTALLED SUCH THAT THE ELEVATION OF THE MULLIONS MATCHES EXISTING STOREFRONT SYSTEMS. G.C. TO VERIFY IN FIELD. 11.CONTRACTOR SHALL VERIFY CONDITION OF ALL EXISTING DOORS AND HARDWARE TO REMAIN. REPLACE OR REFURBISH ALL REQUIRED TO ENSURE DOOR & HARDWARE IS FULLY FUNCTIONAL & WEATHERTIGHT. REMOVE ANY EXISTING SIGNAGE / DECALS. 04 LOFT '04'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 05 LOFT '05'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK- 107 SPA VESTIBULE '107'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 8 --12 A6.1 ---3 109 TOILET '109'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 3 -------3 OPENING SCHEDULES A0.1 25 LOFT '25'3'-0" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 8 A6.0 9sim.A6.0 6'-0" LONG DOOR TRACK- A.GENERAL: PROVIDE THE LINEAR EMERGE50 SECURITY PLATFORM SYSTEM AT ACCESS CONTROL DOORS WITH COMPLETE HARDWARE AND ACCESSORIES AS REQUIRED BY MANUFACTURER. B.ACCESS CONTROL PERFORMANCE IN THE EVENT OF AN EMERGENCY: 1.IN THE EVENT OF A FIRE ALARM OR SPRINKLER SYSTEM ACTIVATION, A DRY CONTACT FIRE RATED RELAY INSTALLED BY THE FIRE ALARM VENDOR WILL CHANGE STATE FROM "NORMALLY CLOSED" TO "NORMALLY OPEN" AND DISRUPT THE POSITIVE LEG OF THE LOCKING DEVICE POWER. THE RELAY WILL CHANGE STATE BACK TO "NORMALLY CLOSED" ONCE THE FIRE ALARM ACTIVATION HAS BEEN RESET, AT WHICH TIME THE LOCKING DEVICE WILL REENGAGE. 2.IN THE EVENT OF A LOSS OF BUILDING POWER, THE LOCKING DEVICE WILL DISENGAGE. THERE IS NO BACKUP BATTERY CONNECTED TO THE POWER SUPPLY. ONCE THE POWER IS RESTORED, THE SYSTEM WILL REBOOT AND REENGAGE THE LOCKING DEVICE. C.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPLICABLE REQUIREMENTS FOR ACCESS AND FOR FIRE RATINGS. 1.HEIGHTS TO COMPLY WITH APPLICABLE CODES AND BHMA RECOMMENDATIONS. 2.ADJUST HARDWARE FOR SMOOTH OPERATION. 3.SEE ELECTRICAL & SHEET A3.0 FOR POWER AND DATA CONNECTIONS REQUIRED AT ACCESS CONTROLLED DOORS. 4.SEE DIAGRAM BELOW FOR TYPICAL FIRE ALARM RELAY CONFIGURATION. D.EQUIPMENT: ACCESS CONTROL HARDWARE TO BE PROVIDED BY ACCESS CONTROL VENDOR. EQUIPMENT INCLUDED, BUT IS NOT LIMITED TO: 1.STOREFRONT MOUNTED EXTERIOR PROXIMITY CARD READER 2.MAGNETIC LOCK 3.EXIT RELEASE BUTTON WITH MOTION DETECTING SENSOR 4.ACCESS CONTROL CONTROLLER PANEL WITH FIRE ALARM SYSTEM RELAY E.CONTACT SALON LOFTS FOR VENDOR. 02 NAIL LOFT '02'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 5 A6.0 9sim.A6.0 8'-6" LONG DOOR TRACK- 03 LOFT '03'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 5 A6.0 9sim.A6.0 8'-6" LONG DOOR TRACK- 06 LOFT '06'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK- 07 SPA LOFT '07'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 6 --12 A6.1 ---3 08 SPA LOFT '08'3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 6 --12 A6.1 ---3 09 LOFT '09'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 10 LOFT '10'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK- 11 LOFT '11'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 5 A6.0 9sim.A6.0 8'-6" LONG DOOR TRACK- 12 LOFT '12'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 13 LOFT '13'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 15 LOFT '15'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 6 -------3 16 LOFT '16'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 17 LOFT '17'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 10 A6.1 9sim.A6.0 6'-10" LONG DOOR TRACK- 18 LOFT '18'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 19 LOFT '19'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 20 LOFT '20'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 21 LOFT '21'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 22 LOFT '22'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 23 LOFT '23'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- 24 LOFT '24'3'-0" x 8'-0" x 1 3/4"S.C. WOOD/GLAZING H.M.-B 6 -------3 110A VACANT LEASESPACE 3'-0" x 7'-0" (EXIST.)H.M. (EXIST.)H.M. (EXIST.)20 MIN.-10 -------- 110B VACANT LEASESPACE 3'-0" x 8'-0" x 1 3/4"S.C. WOOD H.M.-C 9 -------3 113 HALLWAY '113'3'-0" x 7'-0" (EXIST.)ALUM./GLZ. (EXIST.)ALUM. (EXIST.)--7 ------REPLACE GLAZING IN DOOR- SEE 1/A1.0 & 1/A1.1.- 14 LOFT '14'3'-6" x 8'-0" x 1 3/4"H.C. WOOD --D 5 6 A6.0 2 A6.0 9sim.A6.0 10'-0" LONG DOOR TRACK- (EXIST.) ROOM FINISH SCHEDULE ROOM NO.LOCATION REMARKS / NOTESMAT'L FINISH NORTH EAST SOUTH WEST NORTH EAST SOUTH WEST MAT'L HEIGHT CEILINGWALLSBASEFLOOR NOTES: 1.WHERE APPLICABLE, ALL TILE JOINTS ON THE FLOOR MUST ALIGN WITH TILE JOINTS OF THE TILE BASE. SEE DETAIL 8/A2.2. 2.PROVIDE A SEAMING PLAN FOR APPROVAL TO ARCHITECT & SALON LOFTS' REPRESENTATIVE FOR F5 VINYL SHEET FLOORING INSTALLATIONS WHEN APPLICABLE. FINISH SPECIFICATIONS 01 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P6/P2 P1/P2EXP. DECKV.I.F.SEE 1/A4.0 FOR WEST WALL / SEE 2/A4.0 FOR SOUTH WALL.P2 101VESTIBULE CONC F7/F4 T1 -T1 -T1 T1 T1 P1/P2 GYP. BD.9'-0" A.F.F.SEE 5/A6.4 FOR HEIGHTS & FINISHES.P3 103WAITING CONC FI/F2/F3 B1 B1 --P3 P1 --GYP. BD.9'-0" A.F.F.SEE 5/A6.4 FOR HEIGHTS & FINISHESP3 104HALLWAY CONC F1/F2 B1 -B1 -P7/P1 -P7/P1 -EXP. DECKV.I.F.-P2 02 NAIL LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1/P2 P1 GYP. BD.9'-0" A.F.F.SEE 2/A4.0 FOR SOUTH WALL / SEE 5/A6.4 FOR HEIGHTS & FINISHES.P3 102HALLWAY CONC F1/F2 ---B1/T1 ---P7/P1/T1EXP. DECKV.I.F.P2 106HALLWAY CONC F1/F2 B1 B1 B1 B1 P7/P1P7/P1/P2P7/P1/P2P7/P1/P2EXP. DECKV.I.F.SEE 2/A4.0 FOR SOUTH WALL FINISH DIRECTIVE.P2 11 LOFT CONC F1 B1 B1 B1 B1 P6 P1/P2 P1/P2 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR EAST WALL / SEE 2/A4.0 FOR SOUTH WALL.P2 FINISH SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N 108TOILET CONC.F1 B4 T1 T1 B4 P4 T1/P5 T1/P4 P4 GYP. BD.9'-0" A.F.F.-P3 4" STANDARD#114 LUNAR DUST#C40NR3P114 PINNACLEROPPEB1RUBBER WALL BASE (1/8" THICK)120' COIL & PRE-FORMED CORNERS AS REQ'D. -#SW7641 COLLONADE GRAYSEE SPECIFICATIONSSHERWIN WILLIAMSP1WALL PAINT - 18x18#24301 MAGNOLIA WHITESAVANNAHFLORIDA TILET1CERAMIC TILE GROUT: MAPEI #00 WHITE (1/8" MAX. GROUT JOINTS) NOTES: 1.ALL PARTIAL HEIGHT WALLS TO RECEIVE METAL 'J' BEAD OR 'TEAR STRIP' AT TOP. SEE DETAIL 4/A6.3. 2.SEE FINISH PLAN GENERAL NOTES FOR PAINT SHEEN REQUIREMENTS. 3.G.C. TO PROVIDE MATERIAL SAMPLES FOR ALL FINISHES SPECIFIED TO OWNER FOR APPROVAL PRIOR TO ORDERING AND/OR CONSTRUCTION. 4.RUBBER WALL BASE SHALL WRAP AROUND CORNERS MIN. 2'-0" (OR TO INSIDE CORNER) BEFORE A JOINT IS ALLOWED. 5.FLOOR TILE AT TOILET ROOM TO HAVE ROLLED-ON WATERPROOFING APPLIED ON EXISTING FLOORING & UP WALL SURFACES 4" PRIOR TO INSTALLATION. WATERPROOFING TO EXTEND MIN. 2'-0" HORIZONTALLY BELOW ADJACENT FLOOR FINISHES, TYP. WATERPROOFING TO BE MAPEI MAPELASTIC AQUADEFENSE OR APPROVED EQUAL. SEE FINISH DETAILS FOR MORE INFORMATION. SIZECOLOR/PRODUCT NUMBERPATTERN/STYLEMANUFACTURERKEYPRODUCT/MATERIAL REMARKS: -#909-58 BLACKMATTE FINISHFORMICAPL-3PLASTIC LAMINATE - 24x24#7025 MEGA#DT138 TATTOOED MODULARKARASTANF2CARPET TILE (FIELD)QUARTER TURN INSTALLATION -#6212 WHEAT STRANDMATTE FINISHFORMICAPL-2PLASTIC LAMINATE STRAND PATTERN TO RUN VERTICALLY ALONG SURFACES 6" COVED#114 LUNAR DUST#C60CR3P114 PINNACLEROPPEB2RUBBER WALL BASE (1/8" THICK)120' COIL & PRE-FORMED CORNERS AS REQ'D. BROADLOOM (12' W.)#989 DRIVE IN#DC084 GROOVINKARASTANF3CARPET (ACCENT)NO SEAMS ACCEPTABLE- ONE PIECE -#SW7006 EXTRA WHITESEE SPECIFICATIONSSHERWIN WILLIAMSP3WALL / CEILING PAINT - -T.B.D.SEE SPECIFICATIONSSHERWIN WILLIAMSP6WALL PAINT VERIFY W/ TENANT -#SW7023 REQUISITE GRAYSEE SPECIFICATIONSSHERWIN WILLIAMSP4WALL PAINT - -#SW7082 STUNNING SHADESEE SPECIFICATIONSSHERWIN WILLIAMSP5WALL PAINT - -#SW7018 DOVETAILSEE SPECIFICATIONSSHERWIN WILLIAMSP7WALL PAINT (WAINSCOT)- ACOUSTICAL CEILING TILES ARMSTRONG #1912 9/16" BEVELED TEGULAR WHITE 24x24x9/16" ACOUSTICAL CEILING GRID ARMSTRONG SUPRAFINE XL WHITE (WH)9/16"ALL VISIBLE CEILING SUSPENSION WIRES TO BE PAINTED WHITE -ACT1 -#SW7646 FIRST STARSEE SPECIFICATIONSSHERWIN WILLIAMSP2WALL / CEILING PAINT - 24x24#23805 CARBONURBANITEFLORIDA TILEF7CERAMIC TILE GROUT: MAPEI #47 CHARCOAL (1/8" MAX. GROUT JOINTS) -#W-448 FP AFROMOSIA NIGERIAFRENCH POLISH FINISHARBORITEPL-4PLASTIC LAMINATE GRAIN PATTERN TO RUN VERTICALLY -#34337 LITHOS ANTHRACITEREJUVENATIONS STONE RUNARMSTRONGF5VINYL SHEET FLOORING INCLUDE COLOR MATCHED VINYL WELD MATERIAL / INSTALLATION 24x24 (1/4 TURN)#438 WINDSWEPT#L8513 FIRST STEPLEESF4ENTRY MAT -#5875-58 NEUTRAL WEFTMATTE FINISHFORMICAPL-1PLASTIC LAMINATE - BROADLOOM (12' W.)#7025 MEGA#DC138 TATTOOEDKARASTANF6CARPET (SPA SUITE)- 24x24 CUT TO 6"H#23811 CONCRETEURBANITEFLORIDA TILEB4CERAMIC TILE GROUT: MAPEI #27 SILVER (1/8" MAX. GROUT JOINTS) 24x24#23811 CONCRETEURBANITEFLORIDA TILEF1CERAMIC TILE GROUT: MAPEI #27 SILVER (1/8" MAX. GROUT JOINTS) 24x24 CUT TO 4"H#23805 CARBONURBANITEFLORIDA TILEB3CERAMIC TILE GROUT: MAPEI #47 CHARCOAL (1/8" MAX. GROUT JOINTS) FINISH SCHEDULES A0.2 03 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1/P2 P1 EXP. DECKV.I.F.SEE 2/A4.0 FOR SOUTH WALL FOR FINISH DIRECTIVE.P2 04 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1 P1 EXP. DECKV.I.F.-P2 05 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1/P2 P6 EXP. DECKV.I.F.SEE 2/A4.0 FOR SOUTH WALL FINISH DIRECTIVE.P2 06 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1 P1 EXP. DECKV.I.F.-P2 07 SPA LOFT CONC F6 B1 B1 B1 B1 P1 P1 P1 P1 A.C.T.9'-0" A.F.F.-ACT-1 08 SPA LOFT CONC F6 B1 B1 B1 B1 P1 P1 P1 P1 A.C.T.9'-0" A.F.F.-ACT-1 09 LOFT CONC F1 B1 B1 B1 B1 P1 P6 P1 P1 EXP. DECKV.I.F.-P2 10 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2 12 LOFT CONC F1 B1 B1 B1 B1 P1 P1/P2 P6 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR EAST WALL FINISH DIRECTIVE.P2 13 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2 14 LOFT CONC F1 B1 B1 B1 B1 P6/P2 P1/P2 P1 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR EAST WALL / SEE 2/A4.0 FOR NORTH WALL.P2 15 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1/P2 P6 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH & EAST WALLS DIRECTIVE.P2 16 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P1 P6 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2 17 LOFT CONC F1 B1 B1 B1 B1 P1 P6/P1 P1 P1 EXP. DECKV.I.F.-P2 18 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P6 P1 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2 19 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2 20 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P1 P6 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2 21 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1 P6 EXP. DECKV.I.F.-P2 22 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P6 P1 P1 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2 23 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P1 P6 EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2 24 LOFT CONC F1 B1 B1 B1 B1 P1/P2 P1 P6/P1 P1/P2EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH & WEST WALLS DIRECTIVE.P2 25 LOFT CONC F1 B1 B1 B1 B1 P1 P1 P1/P2P6/P1/P2EXP. DECKV.I.F.SEE 1/A4.0 FOR SOUTH & WEST WALLS DIRECTIVE.P2 105HALLWAY CONC F1/F2 -B1 -B1 -P7/P1 -P7/P1EXP. DECKV.I.F.-P2 107SPA VESTIBULE CONC F6 B1 B1 B1 B1 P1 P1 P1 P1 A.C.T.9'-0" A.F.F.-ACT-1 109TOILET CONC.F1 B4 B4 T1 T1 P4 P4 T1/P4 T1/P5 GYP. BD.9'-0" A.F.F.-P3 110VACANT LEASE SPACE CONC EXIST.-EXIST.EXIST.EXIST.-EXIST.EXIST.EXIST.EXP. DECKV.I.F.-EXIST. 111UTILITY CONC F5 B2 B2 B2 B2 P1 P1 P1 P1 EXP. DECKV.I.F.-P2 112HALLWAY CONC F1/F2 -B1 -B1 -P7/P1/P2 -P7/P1/P2EXP. DECKV.I.F.-P2 113HALLWAY CONC F1/F2 B1 B1 -B1 P7/P1/P2P7/P1 -P7/P1EXP. DECKV.I.F.SEE 1/A4.0 FOR NORTH WALL FINISH DIRECTIVE.P2 114HALLWAY CONC F1/F2/F3 B1 -B1 -P7/P1 -P7/P1 P1 VARIES V.I.F.-VARIES RESPONSIBILITY SCHEDULE RUBBER WALL BASE (1/8" THICK) - 4" STANDARD B2 RUBBER WALL BASE (1/8" THICK) - 6" COVED F2 CARPET TILE (FIELD)840 S.F. + 25% = 1,050 S.F. F3 T1 CERAMIC TILE - WALL 304 S.F. + 25% = 380 S.F. 94 S.F. + 25% = 118 S.F. 1,230 L.F. + 10% = 1,353 L.F. 33 L.F. + 10% = 36 L.F. KEY PRODUCT/MATERIAL QUANTITY B1 F6 CARPET (SPA SUITE)249 S.F. + 25% = 312 S.F. SINGLE LOFTS 9 (9 POS) DOUBLE LOFT 0 (0 POS) PREMIUM LOFT 13 (13 POS) NAIL LOFT 2 (2 POS) SPA LOFT 1 (1 POS) TOTAL POS 25 NOTE: - OWNER TO VERIFY QUANTITIES PRIOR TO ORDERING MATERIALS CARPET (ACCENT) CASEWORK SCHEDULE NOTE: GENERAL CONTRACTOR SHALL TAKE DELIVERY, PROVIDE SECURE STORAGE OF OWNER SUPPLIED ITEMS AND INSTALL AS INDICATED ON THE PLANS OR AS DIRECTED BY OWNERS REPRESENTATIVES. SL = SALON LOFTS GC = GENERAL CONTRACTOR LL = LANDLORD E = EXISTING REMARKSFURNISHINSTALL SL REMARKSFURNISHINSTALL LOFTS FINISHES-ALL AREAS HALLWAY/COMMON UTILITY ROOM TOILET ROOMS GCLLESLGCLL SLGCLLESLGCLL SLGCLLESLGCLL SLGCLLESLGCLL SLGCLLESLGCLL SLGCLLESLGCLL GENERAL MECH./ELEC./PLUMB.SLGCLLESLGCLL REMARKSFURNISHINSTALL SLGCLLESLGCLL REMARKSFURNISHINSTALL SIGNAGE W/ WHITE LETTERS - 6"W X 9"H PERMITS & FEES INSPECTIONS TEMPORARY HEAT TEMPORARY ELECTRICAL TEMPORARY WATER JOB PHONE / FAX CLEAN UP INSURANCE FIELD VERIFICATION WARRANTIES & BONDS CERTIFICATE OF OCCUPANCY ROOF (EXISTING) CONCRETE SLAB CONCRETE SLAB/FLR. REPAIR DEMISING WALL STUDS/FRAMING DEMISING WALL GYP. BD. DEMISING WALL INSULATION EXTERIOR SIGNS EXTERIOR ENTRY DOORS & FRAMES EXTERIOR REAR DOOR & FRAME EXTERIOR WINDOWS EXT. STOREFRONT MODIFICATIONS STOREFRONT GLASS DECALS EXT. FINISH MODIFICATIONS STRUCTURAL STEEL DEMOLITION - INTERIOR DEMOLITION - BUILDING SHELL DOOR HARDWARE INT. WD. DOORS & H.M. FRAMES FIRE EXTINGUISHERS/CABINETS - INCLUDES GLAZING UNLESS NOTED OTHERWISE SEE DRAWINGS FOR WORK REQ'D. - SEE DRAWINGS FOR WORK REQ'D. G.C. TO COORDINATE WITH SIGN VENDOR LEVEL & SMOOTH /SEE DWGS. FOR WORK REQ'D. EXIST. SLAB / SEE DWGS. FOR WORK REQ'D. WATERTIGHT - - - - - - - - - - -WATER SERVICE MAIN SANITARY SERVICE MAIN PLUMBING VENT STUB THRU ROOF HVAC UNITS (COMPLETE SYSTEM) HVAC ROOFTOP CURBS HVAC STRUCTURAL SUPPORTS HVAC - VVT/VAV UNITS HVAC DISTRIBUTION (COMPLETE) HVAC DAMPERS TEMPERATURE CONTROL SYSTEM DUCTWORK SMOKE DETECTORS TOILET EXHAUST FAN / GRILLE NAIL LOFT EXHAUST FAN / GRILLES SPA EXHAUST FAN/GRILLE AIR BALANCE REPORT ELECTRICAL SERVICE/METERS ELECTRICAL DISCONNECT IN SPACE ELECTRICAL PANELS ELEC. BREAKER FOR HVAC UNITS ELEC. WIRING FOR HVAC UNITS ELEC. SERVICE RECEPT. FOR HVAC FIRE ALARM SYSTEMS EXT. SIGN ELECTRICAL EXT. LIGHT AT EXIT DOORS WATER METER PLUMB. SAN, HW, CW PIPING GAS PIPING/ACCESSORIES FOR HVAC GAS PIPING/ACCESSORIES FOR W.H. GAS METER CONDENSATE PIPING FIRE SPRINKLER SERVICE FIRE SPRINKLER DISTRIBUTION LOW VOLTAGE WIRING SECURITY SYSTEM WIRING ALARM WIRE RELAY FOR DOORS G.C. TO COORDINATE WITH TENANT'S VENDOR G.C. TO PROVIDE CONDUITS AS REQUIRED- - - - SEE DRAWINGS FOR WORK REQ'D. -- - SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. IF REQUIRED SEE DRAWINGS FOR WORK REQUIRED N/A 2 NEW UNITS / 2 EXISTING UNITS SEE DRAWINGS FOR WORK REQ'D.MILLWORK / CABINETS SHAMPOO SINK / FAUCET SALON CHAIRS ELECTRICAL WIRING / DEVICES LIGHT FIXTURES & BULBS PEDI-SPA CHAIR NAIL SINK / FAUCET SPA LOFT SINK / FAUCET MISC. FURNITURE FRAMED WALL MIRRORS HAIR DRYERS ON WHEELS COAT HOOKS HAIR TRAP BY G.C. - - SEE ELECTRICAL FOR WORK REQUIRED - - - - - MISC. FURNITURE GRAPHICS LIGHT FIXTURES COMPUTER STATION MILLWORK MAIL STATION MILLWORK ELECTRICAL WIRING / DEVICES DATA / TELEPHONE WIRING LOFT IDENTIFICATION/SIGNAGE FRAMED WALL MIRRORS COMPUTER SYSTEM CREDIT CARD MACHINE INTERIOR SIGNAGE GRAPHIC DISPLAY PANELS VESTIBULE MIRROR WATER COOLER - - - - N/A - - - G.C. TO PROVIDE WOOD BLOCKING IN WALL - - GC TO COORD. WITH TENANT'S MILLWORK VENDOR, PROVIDE ELEC. SUPPLY/CONNECTIONGC TO COORD. WITH TENANT'S MILLWORKVENDOR, PROVIDE ELEC. SUPPLY/CONNECTION - SHELVES WATER HEATERS EXPANSION TANK RE-CIRC. PUMP WATER SOFTENER SYSTEM UTILITY SINK WASHER/DRYER PHONE PANEL PLYWD. LIGHT FIXTURES ELECTRICAL WIRING / DEVICES TELEPHONE / DATA WIRING DRINKING FOUNTAIN WATER CLOSET LAVATORY SINK / FAUCET GRAB BARS TOILET ACCESSORIES WALL MIRROR ACCESSIBILITY SIGNAGE LIGHT FIXTURES ELECTRICAL WIRING / DEVICES VANITY COUNTERTOP TRASH CANS SOAP / LOTION DISPENSER MILLWORK STORAGE CABINETS PAINTING CARPET/CARPET TILES VINYL FLOORING RUBBER BASE CERAMIC TILE CERAMIC TILE ACCESSORIES/GROUT ACOUSTICAL CLG. TILE/GRID RUBBER TRANSITION STRIPS ENTRY MAT - WHERE APPLICABLE INCLUDE ALL COMPONENTS OF ACT1 INCLUDE ALL SCHLUTER STRIPS AS DETAILED - - - SEE A2.4 - - - - MATTE BLACK UNISEX RESTROOM SIGNAGE - - - - - N/A - - - - - - - FURNITURE SCHEDULE MISCELLANEOUS OWNER SUPPLIED ITEMS FINISH MAT'L. QUANTITIES LOFT QUANTITIES KEYQUANTITY 22 DESCRIPTION SHAMPOO SINK BASE W/ SHAMPOO SINKC1 44 STYLIST BASE CABINETC2 48 STYLIST UPPER CABINETC3 44 STYLIST COUNTERTOP (VERIFY LENGTH W/ PLAN SET DETAILS)C4 26 FRAMED WALL MIRROR 'A' (3'-4" X 4'-8")C5 0C6 2 PAY STATIONC7 0 MAIL STATIONC8 2 SPA CABINETS (BASE & UPPER CABINETS, COUNTERTOPS) 1 NAIL POLISH CABINET C9 1 NAIL LOFT STORAGE C10 1 NAIL CARTSC12 FRAMED WALL MIRROR 'B' (3'-4" X 6'-0") C11 C13 2 WAY FINDING MILLWORK. SEE A4.2C14 C15 FRAMED WALL MIRROR 'C' (2'-6" X 4'-2") - TOILET ROOM2 C16 STYLIST TOOL CART22 NOTE: - OWNER TO VERIFY QUANTITIES PRIOR TO ORDERING MATERIALS QUANTITY DESCRIPTION NOTE: - OWNER TO VERIFY QUANTITIES PRIOR TO ORDERING MATERIALS QUANTITY DESCRIPTIONKEYKEY 22 STYLIST CHAIRSF1 0 EUROPEAN SINK / CHAIRF2 NAIL SINKF3 1 NAIL TABLESF4 2 NAIL CHAIRSF5 1 PEDI-SPAF6 1 WASHER / DRYERF7 2 COMPUTERF8 6 (VERIFY)WAITING CHAIRSF9 2 (VERIFY)WAITING TABLESF10 2F19 25 LOFT SIGNAGE W/ CARD HOLDERF12 0 INDIVIDUAL CARD HOLDERF13 22 HAIR DRYER ON WHEELSF14 2 TOILET ROOM TRASH CANF15 2 SOAP / LOTION DISPENSERF16 0 5' X 5' FATIGUE MATF17 0 3' X 4' FATIGUE MATF18 1 0 (VERIFY)WAITING BENCHF11 F20 1 UTILITY TRASH CAN SPA TABLE M1 LOFT & ENTRY DOOR PULL21 COAT HOOKS50 'A' LIGHT FIXTURE (CUSTOM LAMP SHADE FIXTURE)22 'B' LIGHT FIXTURE (4'-0" TRACK WITH 3 HEADS)22 MATTE BLACK UNISEX SIGNAGE W/ WHITE LETTERS - 6"W X 9"H2 M2 M3 M5 M6 M7 M8 M9 M4 M10 M11 M12 M13 M14 M15 M16 M17 M18 'C' LIGHT FIXTURE (COMPACT FLUORESCENT DOWNLIGHT)0 2 'D' LIGHT FIXTURE (METAL HALIDE DOWNLIGHT) 10 11 'E' LIGHT FIXTURE (2'X4' LAY-IN FIXTURE)2 'F' LIGHT FIXTURE (3'-6" FLUORESCENT WALL LIGHT)44 'G' LIGHT FIXTURE (1'X4' INDUSTRIAL FLUORESCENT FIXTURE)4 'H' LIGHT FIXTURE (LED LINEAR WALL WASH FIXTURE) 'J' LIGHT FIXTURE (LINEAR LED FLEX FIXTURE)SEE DETAILS 'C2' LIGHT FIXTURE (HALOGEN DOWNLIGHT WITH DIMMER) 'K' LIGHT FIXTURE (2'-6" FLUORESCENT WALL LIGHT)2 'EM2' LIGHT FIXTURE (OUTDOOR EMERGENCY LIGHT)2 'L' LIGHT FIXTURE (5'Ø FLUORESCENT FIXTURE)2 'C1' LIGHT FIXTURE (C.F.L. DOWNLIGHT W/ EMER. BATTERY PACK) QUANTITYDESCRIPTIONKEY 'X-1' LIGHT FIXTURE (EXIT LIGHT WITH DIRECTIONAL ARROW)13 'X-2' LIGHT FIXTURE (RECESSED EMERGENCY LIGHT)7 SLIDING DOOR TRACK HARDWARE - 8'-6" LONG TRACK - LOFTS 02, 03, 11 M26 3 SLIDING DOOR TRACK HARDWARE - 10'-0" LONG TRACK - LOFTS 04, 09, 12, 13, 14, 16, 18, 19, 20, 21, 22, 2312 M27 LOFT TYPE QUANTITY NOTE: G.C. SHALL VERIFY SALON LOFTS SUPPLIED FINISH MATERIAL QUANTITIES INDICATED WITHIN 7 DAYS OF BEING AWARDED CONTRACT FOR CONSTRUCTION. COORD. FINAL VERIFIED QUANTITIES TO SALON LOFTS REPRESENTATIVE. INCLUDING FINAL CONNECTION SLIDING DOOR TRACK HARDWARE - 6'-10" LONG TRACK - LOFT 05, 06, 10, 174 FRAMED WALL MIRROR 'D' (6'-8" X 5'-0") - WAITING ROOM1 ELECTRICAL TRANSFORMER M20 'M' LIGHT FIXTURE (4'Ø FLUORESCENT FIXTURE)2 HARDWOOD SILL GUIDE TRACK - 8'-6" LONG TRACK - LOFTS 02, 03, 11 HARDWOOD SILL GUIDE TRACK - 10'-0" LONG TRACK - LOFTS 04, 09, 12, 13, 14, 16, 18, 19, 20, 21, 22, 23 HARDWOOD SILL GUIDE TRACK - 7'-1" LONG TRACK - LOFT 05, 06, 10, 17 SEE DRAWINGS FOR WORK REQUIRED IF APPLICABLE VESTIBULE MIRROR TRIM - LADDER HANGER - TANKLESS WATER HEATERS (INT. WALL MTD.) M21 'N' LIGHT FIXTURE (3'Ø FLUORESCENT FIXTURE)1 M28 INTERIOR ALUM. DOORS & FRAMES INCLUDES GLAZING ROOF WORK (NEW)USE LANDLORD APPROVED ROOFER IF REQ'D. SEE DRAWINGS FOR WORK REQ'D. G.C. TO PROVIDE WOOD BLOCKING IN WALL G.C. TO PROVIDE WOOD BLOCKING IN WALL G.C. TO PROVIDE WOOD BLOCKING IN WALL G.C. TO PROVIDE WOOD BLOCKING IN WALL G.C. TO PROVIDE WOOD BLOCKING IN WALL SEE DRAWINGS FOR WORK REQ'D. N/A INCLUDE AT TRANSITION PIECES AS DETAILED 3 12 4 94 SQ.YD.+25%= 118 SQ.YD. 11 SQ.YD.+25%= 14 SQ.YD. 35 SQ.YD. + 25%= 44 SQ.YD. - - SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. - - - SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. 2 NEW / 2 EXISTING M19 M29 InterlockingRock BLOCK WALL -InterlockingRock PANEL WALL modulararts InterlockingRock BLOCKS - 'OHM'9 C17 SALON LOFTS PUCK AND GRAPHIC PANEL1 SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. SEE DRAWINGS FOR WORK REQ'D. INTERIOR GLZ./SILLS/HEADS/ETC. G.C. TO PROVIDE WOOD BLOCKING IN WALL F4 CARPET (ENTRY MAT)33 S.F. + 25% = 42 S.F. 4 SQ.YD. + 25%= 5 SQ.YD. N/A SEE DRAWINGS FOR WORK REQ'D. F21 WAITING GATHERING HEIGHT CHAIR F22 WAITING GATHERING HEIGHT TABLE M22 'P' LIGHT FIXTURE (2'Ø FLUORESCENT FIXTURE)0 M24 modulararts InterlockingRock PANELS - PATTERN T.B.D.17 M30 SEE DRAWINGS FOR WORK REQ'D. N/A SEE DRAWINGS FOR WORK REQ'D. SKYLIGHTS - SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N URINAL TOILET PARTITIONS N/A F23 2 46" LED-LCD DISPLAY & MOUNT WAY FINDING MILLWORK LED-LCD DISPLAY & MOUNT G.C. TO COORD. ELEC./DATA REQUIREMENTS. - 2 (VERIFY) 1 (VERIFY) SEE DETAILS M23 0 'R' LIGHT FIXTURE (DOWNLIGHT FIXTURE) B4 CERAMIC TILE BASE - 6" HIGH 12 S.F. + 25% = 15 S.F. F1 CERAMIC TILE - FLOOR 3,678 S.F. + 25% = 4,597 S.F. N/A B3 CERAMIC TILE BASE - 4" HIGH 0 S.F. + 25% = 0 S.F. - N/A N/A F7 CERAMIC TILE - FLOOR 14 S.F. + 25% = 15 S.F. M25 M31 M32 HARDWOOD SILL GUIDE TRACK - 6'-3" LONG TRACK - LOFT 251 RESPONSIBILITY SCHEDULE A0.3 SLIDING DOOR TRACK HARDWARE - 6'-0" LONG TRACK - LOFT 251 M33 N/A N/A - W T W GRID GRID GRID GRID NOTE: AREA OF FLOOR SLAB TRENCHING (SHOWN HATCHED) FOR UNDER-SLAB PLUMBING & ELECTRICAL. REPLACE ALL FLOOR SLAB REMOVED WITH 'LIKE NEW' CONSTRUCTION, BUT IN NO CASE LESS THAN 4" CONC. SLAB W/ 6x6-W1.4/21.4 WWF AT MID-DEPTH. DOWEL PIN TO EXIST. SLAB AS REQ'D. 1 4 6 5 7 7 9 9 10 5 5 5 111 3 8 6' - 0 " M. O . 8' - 8 " M. O . 1 4' - 0 " M. O . 4' - 0 " M. O . 4' - 0 " M. O . 22 2 2 2 2 22 2 6' - 8 " 4' - 8 " 6' - 8 " 8" 4' - 8 " 3 12 12 1313 14 14 14 15 16 16 16 16 16 4' - 0 " 10 ' - 8 " 3' - 5 " 8' - 2 " 9' - 2 3 / 8 " 3' - 7 1 / 2 " 2' - 6 " TR E N C H TYP. TYP. TR E N C H 6' - 7 " ± TR E N C H 21'-0"6"5'-1"7'-5"12'-4"4'-6"1'-2" 1' - 3 " 3'-4" 8 TYP. 2'-3"2'-3" 1' - 0 " 2' - 0 " 2' - 9 " 3 TYP. 4"3'-8"22'-2 1/2"2'-10"8'-8 1/4"15'-3 3/4"15'-8 3/4"5'-11 1/4"1'-5"5'-2"9'-8"4'-0" 4' - 6 " 4' - 6 " TYP.11'-1"±TRENCH TRENCH 4' - 5 1 / 2 " ± TR E N C H 12 4'-0"30'-4"60'-9 1/4"4'-0" 8 3 TYP. TYP. 17 ' - 2 " 4' - 0 " 10 ' - 8 " 1' - 8 " 1' - 8 " 7" 2' - 0 1 / 2 " 4' - 0 3 / 4 " TR E N C H TR E N C H 4'-0"12'-0"7'-0"31'-5"TRENCH3'-2"TRENCH 8' - 8 " 8 TYP. 18 18 4' - 0 " 20 2' - 0 " 19 TYP.TYP. 3'-9 1/2" TYP.TYP.TYP.TYP. 17 21 17 17 TYP. TYP. 14 14 23 TYP. NOTE: TRENCHING LAYOUT INDICATED IS BASED ON CONNECTIONS TO EXISTING UNDERGROUND SANITARY LINE LOCATIONS ASSUMED BY EXISTING TOILET ROOM LOCATIONS. CONTRACTOR SHALL VERIFY AND COORDINATE ANY DEVIATIONS REQUIRED. 1515 22 15 EXISTING COMMON EXIT CORRIDOR 15 TYP. 18 18 N SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N DEMOLITION & FLOOR TRENCHING PLAN A1.0 1 A1.0 3/16"=1'-0" DEMOLITION & FLOOR TRENCHING PLAN DEMOLITION KEY NOTES 1 2 3 4 5EXISTING STOREFRONT DOOR TO BE REMOVED SHOWN DASHED. PREP OPENING FOR NEW STOREFRONT SYSTEM INFILLED TO MATCH EXISTING AS SCHEDULED. EXIST. STOREFRONT WINDOWS TO REMAIN. G.C. IS RESPONSIBLE FOR ALL STOREFRONT REPAIR NEEDED. ENSURE ALL SEALS, GASKETS, GLASS, FRMG., ETC ARE IN GOOD CONDITION. REPLACE ALL DAMAGED PARTS. REMOVE THROUGH WALL/GLASS PENETRATIONS. PATCH GLASS/FRAMING SYSTEM TO MATCH EXIST. AS REQUIRED. DEMOLISH, REMOVE, AND LEGALLY DISCARD ALL EXISTING IMPROVEMENTS THROUGHOUT AREA OF WORK INCLUDING, BUT NOT LIMITED TO: PARTITIONS, DOORS, CEILINGS, FLOORING, MILLWORK, LIGHTS, ELECTRICAL, PLUMBING, AND DUCTWORK, ETC. (SHOWN DASHED). VERIFY EXTENTS. EXISTING STRUCTURAL COLUMN & FURRING TO REMAIN SHOWN SHADED. PROTECT FROM DAMAGE DURING DEMOLITION AS REQUIRED. SEE SHEET A2.0 FOR ADDITIONAL INFORMATION. REMOVE EXISTING PORTION OF MASONRY WALL AS INDICATED. PREP OPENING FOR NEW WINDOW & FRAME AS SCHED. SEE SHEET A1.1 FOR EXTENTS OF NEW WORK REQUIRED. REMOVE EXISTING PORTION OF MASONRY WALL AS INDICATED. PREP OPENING FOR NEW STOREFRONT AS SCHED. SEE SHEET A1.1 FOR EXTENTS OF NEW WORK REQUIRED. EXISTING ELECTRICAL SERVICE PANELS TO BE REMOVED / RELOCATED. REMOVE ALL UNUSED CONDUITS/WIRES/ETC. BACK TO POINT OF ORIGINATION AS REQ'D. COORD. REQUIREMENTS WITH ELEC. PLANS. EXISTING CONCRETE FLOOR SLAB TO REMAIN. REMOVE ANY EXISTING FLOOR COVERINGS / COATINGS / ELECTRICAL OUTLETS. PATCH & REPAIR AS NEEDED TO 'LIKE NEW' CONDITION. CONCRETE SLAB TO BE SMOOTH AND LEVEL PRIOR TO NEW CONSTRUCTION; REPAIR ANY AREAS OF HEAVE ACCORDINGLY. PREPARE SURFACE FOR NEW FINISHES AS SCHEDULED. EXISTING HVAC UNITS ON ROOF ABOVE SERVING TENANT'S SPACE TO REMAIN. PROTECT AS REQ'D. REMOVE ALL ASSOCIATED DUCTWORK, ETC. BACK TO UNIT DROPS. SEE MECHANICAL PLANS FOR NEW WORK REQ'D. EXISTING HVAC UNIT ON ROOF ABOVE SERVING TENANT'S SPACE TO BE REMOVED AND REPLACED. COORDINATE WITH MECHANICAL FOR PLACEMENT OF NEW HVAC UNIT. REMOVE EXISTING MAIL DROP BOX IN STOREFRONT DOOR. REPLACE WITH GLAZING TO MATCH EXISTING. SEE A1.1 FOR ADDITIONAL INFORMATION. REMOVE EXISTING FURRING AROUND EXISTING COLUMN AS INDICATED. PROTECT COLUMN FROM DAMAGE DURING DEMOLITION & CONSTR. EXISTING WATER METERS TO BE REMOVED AS REQ'D. CAP ANY EXISTING CONNECTIONS AS REQ'D. & SEE MECH. DRAWINGS FOR NEW SERVICE. FALSE COLUMNS & SOFFITS ABOVE TO BE REMOVED. PATCH AND REPAIR ADJACENT SURFACES AS REQ'D. TO MATCH EXISTING. REMOVE EXIST. FLOOR SINKS/FLOOR DRAINS & CAP CONNECTIONS BELOW SLAB AS REQ'D. SEE MECH. DRAWINGS FOR MORE INFORMATION. REMOVE EXISTING ROOF DECK & ROOFING AS REQ'D. TO INSTALL NEW SKYLIGHTS. SEE SHEET A1.1 FOR MORE INFORMATION. EXISTING DOOR & FRAME TO REMAIN. PROTECT AS REQ'D. DURING DEMOLITION & CONSTRUCTION. G.C. TO REPLACE / REPAIR ANY DAMAGE/ HARDWARE AS REQUIRED. NEW UNDERGROUND PLUMBING TRENCH TO CONNECT TO EXISTING UNDERGROUND SANITARY LINE. VERIFY ALL EXISTING LOCATIONS. EXISTING EXTERIOR METAL RAILING TO BE REMOVED. REPAIR CONCRETE SIDEWALK AS REQUIRED TO MATCH ADJACENT SURFACES. EXIST. FIREPLACE TO BE REMOVED ALONG WITH ASSOCIATED VENTING, GAS LINES, ETC. PATCH & REPAIR ADJACENT AS REQ'D. TO MATCH EXIST. REMOVE EXISTING H.M. DOOR & FRAME AS REQ'D. PREP OPENING FOR NEW MASONRY INFILL AS INDICATED ON SHEET A1.1. EXISTING GREASE TRAP RECESSED INTO FLOOR SLAB TO BE REMOVED IN ITS ENTIRETY, INCLUDING ALL ASSOCIATED PLUMBING UNDER SLAB. INFILL SLAB WITH 'LIKE CONSTRUCTION' TO MATCH EXISTING. EXISTING WATER LINE & EXTERIOR HOSE BIB TO REMAIN. PROTECT FROM DAMAGED DURING DEMOLITION AND NEW CONSTRUCTION. 7 8 9 6 10 11 12 13 14 15 16 17 18 19 20 21 22 23 W W GRID GRID GRID GRID EXIST. STL. JOISTS, TYP. VERIFY LOCATIONS IN FIELD. A1.1 2 A1.2 1 4' - 8 " 4' - 0 " M. O . 6' - 8 " 4' - 0 " M. O . 6' - 8 " 4' - 0 " M. O . A1.1 3 A1.1 3 A1.1 3 5'-3 1/2"14'-6"16'-6"26'-6"26'-2"± A1.1 4 A1.2 2 A1.2 3 2' - 8 " 6' - 0 " 4' - 8 " 8' - 8 " 8" 1 3 2 22 3 3 3 4 4 55 5 5 5 66 6 7 8 9 8 6'-0" 11 10 13 6 13 12 RETURN GYP. BD. TO FRAME AT HEAD AND JAMBS. SEAL TO FRAME. LINE OF GYP. BD. WALL BEYOND. EXIST. EXTERIOR BIT. SURFACE TO REMAIN. HEAD FLASHING, SEALANT & SHIM SPACE. NEW STL. LINTEL W/ CMU INFILL AT DOOR HEAD- SEE STRUCT. ALL EXPOSED STL. SHALL BE PRIMED & PAINTED. EXISTING CMU WALL (SHOWN SHADED) TO REMAIN. PATCH TO MATCH AS REQ'D. DUE TO NEW CONSTRUCTION. TOP OF INTERIOR SLAB +0'-0" EXIST. CONC. SLAB TO REMAIN. EXIST. CMU. WALL (SHOWN SHADED). 2"4 12" 6' - 0 " 2' - 8 " NEW 2"x4 1/2" DARK BRONZE ANODIZED THERMALLY BROKEN ALUM. GLAZING FRAME W/ 1" TINTED INSUL. GLASS (CENTER SET). PREFIN. SILL FLASHING TO MATCH GLAZING FRAMES. FLASHING TO FULLY SEAT FRAME & LAP OVER CMU WALL WITH HEMMED DRIP EDGE AS INDICATED. PATCH/REPAIR/ REPLACE INTERIOR WALL FURRING TO MATCH EXIST. AS NEEDED. P.LAM. WINDOW SILL OVER ICE & WATER MEMBRANE ON 34" TREATED PLYWD. SILL. EXIST. EXTERIOR CONC. SURFACE. VFY. LEVEL WITH INTERIOR SLAB. PREFINISHED ALUM. THRESHOLD SET IN BED OF MASTIC. NEWEXIST. 1/2" EXPANSION JOINT. 9' - 0 " NEW 2"x4 1/2" DARK BRONZE ANODIZED THERMALLY BROKEN ALUM. STOREFRONT SYSTEM W/ 1" TINTED INSUL. GLASS (CENTER SET). RETURN GYP. BD. TO FRAME AT HEAD AND JAMBS. SEAL TO FRAME. LINE OF GYP. BD. WALL BEYOND. PATCH/REPAIR/REPLACE INT. WALL FURRING TO MATCH EXISTING AS NEEDED. EXTEND AND/OR PROVIDE NEW FURRING SYSTEM AT DOOR / WINDOW HEAD & UP TO ROOF DECK. HEAD FLASHING, SEALANT & SHIM SPACE. NEW STL. LINTEL W/ CMU INFILL AT DOOR HEAD- SEE STRUCT. ALL EXPOSED STL. SHALL BE PRIMED & PAINTED. EXISTING SOFFIT & MASONRY WALL (SHOWN SHADED) TO REMAIN. PATCH TO MATCH AS REQ'D. DUE TO NEW CONSTRUCTION. 2"4 12" TOP OF INTERIOR SLAB +0'-0" EXIST. EXTERIOR CONC. SURFACE TO REMAIN. 6' - 4 " NEW 2"x4 1/2" DARK BRONZE ANODIZED THERMALLY BROKEN ALUM. STOREFRONT SYSTEM W/ 1" TINTED INSUL. GLASS (CENTER SET). RETURN GYP. BD. TO FRAME AT HEAD AND JAMBS. SEAL TO FRAME. LINE OF GYP. BD. WALL BEYOND. EXISTING SOFFIT & MASONRY WALL (SHOWN SHADED) TO REMAIN. PATCH TO MATCH AS REQ'D. DUE TO NEW CONSTRUCTION. 2"4 12" TOP OF INTERIOR SLAB +0'-0" B.O. SOFFIT +9'-6"± (VFY.) 2' - 8 " HEAD FLASHING, SEALANT & SHIM SPACE. NEW STL. LINTEL W/ CMU INFILL AT DOOR HEAD- SEE STRUCT. ALL EXPOSED STL. SHALL BE PRIMED & PAINTED. B.O. SOFFIT +9'-6"± (VFY.) EXIST. CONC. SLAB TO REMAIN. PATCH/REPAIR/ REPLACE INTERIOR WALL FURRING TO MATCH EXIST. AS NEEDED. P.LAM. WINDOW SILL OVER ICE & WATER MEMBRANE ON 34" TREATED PLYWD. SILL. PREFIN. SILL FLASHING TO MATCH GLAZING FRAMES. FLASHING TO FULLY SEAT FRAME & LAP OVER MASONRY WALL WITH HEMMED DRIP EDGE AS INDICATED. EXIST. FOUNDATION WALL (SHOWN SHADED). #4x1'-0" LG. DOWEL @ 24" O.C. CENTER ON NEW/EXIST. JOINT. G.C. FIELD VFY. -0'-8" #4 Ø CONT. EXIST. CMU. FND. WALL ASSUMED- G.C. FIELD VFY.- GROUT TOP COURSE SOLID CONTINUOUS. #4x1'-0" LG. DOWEL @ MID-DEPTH @ 24" O.C. EMBED 4" INTO EXIST. CONC. W/ EPOXY ADHESIVE. NEW CONC. SLAB INFILL AS REQ'D. FOR NEW DOOR OPENING. PATCH / REPAIR / REPLACE INT. WALL FURRING TO MATCH EXISTING AS NEEDED. EXTEND AND/OR PROVIDE NEW FURRING SYSTEM AT DOOR / WINDOW HEAD & UP TO ROOF DECK. PATCH/REPAIR/REPLACE INT. WALL FURRING TO MATCH EXISTING AS NEEDED. EXTEND AND/OR PROVIDE NEW FURRING SYSTEM AT DOOR / WINDOW HEAD & UP TO ROOF DECK. STL. ANGLE- SEE STRUCT. SKYLIGHT SET IN CONTIN. BED OF MASTIC COMPATIBLE WITH ROOFING MATERIAL. STAINLESS STEEL FASTENERS AS REQ'D. BY MFR. SKYLIGHT TO BE INSTALLED WEATHER- TIGHT PER MFR.'S RECOMMENDATIONS. LAP FLASHING UP & OVER NEW 2x WD. CURB & TIE INTO EXIST. ROOF- TYP. ALL SIDES. EXIST. ROOF TO REMAIN. REPAIR AS NECESSARY. NEW TREATED (2) 2x WD. CURB AT ALL SIDES. EXIST. MTL. DECKING. 3" 4'-1 1/4" VERIFY W/ MANUFACTURER 4" MI N . 3" W W GRID GRID GRID GRID EXIST. STL. JOISTS, TYP. VERIFY LOCATIONS IN FIELD. A1.1 2 A1.2 1 4' - 8 " 4' - 0 " M. O . 6' - 8 " 4' - 0 " M. O . 6' - 8 " 4' - 0 " M. O . A1.1 3 A1.1 3 A1.1 3 5'-3 1/2"14'-6"16'-6"26'-6"26'-2"± A1.1 4 A1.2 2 A1.2 3 2' - 8 " 6' - 0 " 4' - 8 " 8' - 8 " 8" 1 3 2 22 3 3 3 4 4 55 5 5 5 66 6 7 8 9 8 6'-0" 11 10 13 6 13 12 BUILDING SHELL MODIFICATIONS PLAN & DETAILS A1.1 SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N 1 A1.1 1/8"=1'-0" BUILDING SHELL MODIFICATIONS PLAN 2 A1.1 3/4"=1'-0" WALL SECTION @ DOOR KEY NOTES 1 2 3 4 NEW DARK BRONZE ALUMINUM/GLAZING DOOR & FRAME AS SCHEDULED WITH 1" TINTED INSULATED GLASS (TEMPERED WHERE REQUIRED BY CODE). SEE DOOR SCHEDULE. NEW DARK BRONZE ANODIZED ALUMINUM GLAZING FRAME INFILL AS REQUIRED WITH 1/8" TINTED TEMPERED SAFETY GLASS TO MATCH EXISTING STOREFRONT. NEW DARK BRONZE ANODIZED ALUMINUM GLAZING FRAME WITH 1" TINTED INSULATED GLASS (TEMPERED WHERE REQUIRED BY CODE) AS SCHEDULED. PATCH, REPAIR & INFILL EXISTING CONCRETE FLOOR SLAB AS REQUIRED. SLAB TO BE LEVEL & SMOOTH THROUGHOUT FOR NEW FINISHES AS SCHEDULED. PROVIDE & INSTALL 4'-0"x4'-0" DOME STYLED THERMAL MOUNTED CURB FIXED SKYLIGHT BY WASCO SKYLIGHT "DCSNT" MODEL #5252 WITH A CLEAR ANODIZED ALUMINUM FINISH AT ROOF. ALUMINUM PERIMETER PRE-SEALED AT FACTORY, INSTALLATION ON TREATED WOOD CURB. ALL ROOFING, CURBS, ETC. FOR COMPLETE WATERTIGHT INSTALLATION. SEE DETAIL 5/A1.1 & STRUCTURAL PLANS FOR MORE INFORMATION. EXTEND GYP. BD. & FURRING UP TO DECK WHERE NONE EXISTS. ALIGN W/ EXIST. WALL FURRING & PREP FOR FINISHES AS SCHED. REPLACE EXISTING RTU WITH NEW RTU IN SAME LOCATION AS SCHEDULED. SEE MECH. DRAWINGS FOR MORE INFORMATION. EXISTING RTU TO REMAIN. SEE MECHANICAL PLANS. EXISTING GAS METERS. PROTECT FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION. REPLACE EXISTING GLAZING IN STOREFRONT DOOR W/ 1/8" TEMPERED TINTED SAFETY GLASS TO MATCH EXISTING (VERIFY). NEW RTU AS SHOWN. VERIFY FINAL LOCATION AND ADDITIONAL INFORMATION WITH STRUCTURAL & MECHANICAL DRAWINGS. INFILL OPENING WITH CMU / FURRING / GYP. BD. CONSTRUCTION TO MATCH EXISTING. EXISTING DOOR & FRAME. SEE DOOR SCHEDULE FOR ANY WORK REQUIRED. 5 6 7 8 9 3 A1.1 3/4"=1'-0" WALL SECTION @ WINDOW 5 A1.1 1 1/2"=1'-0" SKYLIGHT DETAIL 4 A1.1 3/4"=1'-0" WALL SECTION @ WINDOW N 10 11 12 13 GRID GRID GRID GRID GRID GRID U.N.O., EXIST. CONDITIONS AT EXTERIOR STOREFRONT WALLS TO REMAIN. U.N.O., EXIST. CONDITIONS AT EXTERIOR STOREFRONT WALLS TO REMAIN. U.N.O., EXIST. CONDITIONS AT EXTERIOR STOREFRONT WALLS TO REMAIN. LEASELINE LEASELINE PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, & INSTALLATION BY TENANT'S SIGN VENDOR. ELEC. CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL. CENTER SIGNAGE AS INDICATED. PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, & INSTALLATION BY TENANT'S SIGN VENDOR. ELEC. CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL. CENTER SIGNAGE AS INDICATED. EXISTING GAS SERVICE METERS. A1.1 2 A1.1 4 REMOVE EXISTING PORTION OF WALL & INFILL WITH NEW DARK BRONZE ANODIZED FRAME W/ GLAZING AS SCHED. PAINT ADJACENT WALL SURFACES AS REQ'D. TO MATCH EXISTING. COORD. WITH LANDLORD. W-3 4'-8"4'-0" M.O. 6'-8"4'-0" M.O. 6'-8"4'-0" M.O. W-3W-3 A1.1 3 A1.1 3 A1.1 3 W-2101AW-1 REMOVE EXISTING PORTION OF WALL & INFILL WITH NEW DARK BRONZE ANODIZED FRAME W/ GLAZING AS SCHED. REMOVE EXISTING PORTION OF WALL & INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT SYSTEM AS SCHED. REMOVE EXISTING STOREFRONT DOOR & TRANSOM AND INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT FRAME W/ GLAZING AS SCHED. TO MATCH EXISTING. W-1 REMOVE EXISTING STOREFRONT DOOR & TRANSOM AND INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT FRAME W/ GLAZING AS SCHED. TO MATCH EXISTING. W-1 REMOVE EXISTING STOREFRONT DOOR & TRANSOM AND INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT FRAME W/ GLAZING AS SCHED. TO MATCH EXISTING. SALON LOFTS SALON LOFTS HAIR SKIN NAILS MASSAGE INFILL EXISTING DOOR OPENING W/ CMU TO MATCH EXISTING. PAINT TO MATCH REAR WALL. COORDINATE COLOR WITH LANDLORD. GRID GRID GRID GRID GRID GRID U.N.O., EXIST. CONDITIONS AT EXTERIOR STOREFRONT WALLS TO REMAIN. U.N.O., EXIST. CONDITIONS AT EXTERIOR STOREFRONT WALLS TO REMAIN. U.N.O., EXIST. CONDITIONS AT EXTERIOR STOREFRONT WALLS TO REMAIN. LEASELINE LEASELINE PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, & INSTALLATION BY TENANT'S SIGN VENDOR. ELEC. CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL. CENTER SIGNAGE AS INDICATED. PROPOSED STOREFRONT SIGNAGE, PERMIT, MATERIALS, & INSTALLATION BY TENANT'S SIGN VENDOR. ELEC. CONTRACTOR SHALL PROVIDE ELEC. AS INDICATED ON ELEC. PLANS & PROVIDE FINAL CONNECTION. SUBMIT SIGN DESIGN DRAWINGS TO L.L. FOR REVIEW & APPROVAL. CENTER SIGNAGE AS INDICATED. EXISTING GAS SERVICE METERS. A1.1 2 A1.1 4 REMOVE EXISTING PORTION OF WALL & INFILL WITH NEW DARK BRONZE ANODIZED FRAME W/ GLAZING AS SCHED. PAINT ADJACENT WALL SURFACES AS REQ'D. TO MATCH EXISTING. COORD. WITH LANDLORD. W-3 4'-8"4'-0" M.O. 6'-8"4'-0" M.O. 6'-8"4'-0" M.O. W-3W-3 A1.1 3 A1.1 3 A1.1 3 W-2101AW-1 REMOVE EXISTING PORTION OF WALL & INFILL WITH NEW DARK BRONZE ANODIZED FRAME W/ GLAZING AS SCHED. REMOVE EXISTING PORTION OF WALL & INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT SYSTEM AS SCHED. REMOVE EXISTING STOREFRONT DOOR & TRANSOM AND INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT FRAME W/ GLAZING AS SCHED. TO MATCH EXISTING. W-1 REMOVE EXISTING STOREFRONT DOOR & TRANSOM AND INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT FRAME W/ GLAZING AS SCHED. TO MATCH EXISTING. W-1 REMOVE EXISTING STOREFRONT DOOR & TRANSOM AND INFILL WITH NEW DARK BRONZE ANODIZED STOREFRONT FRAME W/ GLAZING AS SCHED. TO MATCH EXISTING. SALON LOFTS SALON LOFTS HAIR SKIN NAILS MASSAGE INFILL EXISTING DOOR OPENING W/ CMU TO MATCH EXISTING. PAINT TO MATCH REAR WALL. COORDINATE COLOR WITH LANDLORD. EXTERIOR ELEVATIONS A1.2 SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N 1 A1.2 1/8"=1'-0" NORTH ELEVATION 2 A1.2 1/8"=1'-0" WEST ELEVATION 3 A1.2 1/8"=1'-0" EAST ELEVATION HALLWAY AL I G N SEALANT TO MATCH GROUT. WALL TILE T1 WALL SYSTEM AS SCHEDULED. VESTIBULE SEALANT TO MATCH GROUT. WALL TILE T1 LAP TILE. 1'-6" FROM FACE OF FRAME/TILE TO CORNER GYP. BD. 3/8" VFY. FACTORY EDGE. 3/8" VFY. FINISHED FLOOR (TILE) 5/ 8 " 4" BASE VARIES- VERIFY PARTITION WALL & PAINT PER SCHED. HOLD GYP. BD. 5/8" OFF SLAB, TYP. TILE MUST BE INSTALLED TIGHT TO GYP. BD. WALL SURFACE, TYP. GRID 63 ' - 6 3 / 4 " LE A S E L I N E T O L E A S E L I N E 101'-0 1/2" LEASELINE TO LEASELINE 3'-8 1/4" GRID GRID GRID 01020305 04 06 07 107 08 0910 108109 111 11 12 14 15 13 16 17 19 18 20 21 22 23 24 25 101 102103 104 105 106 110 112 113 114 FE FE FE EXISTING CONDITIONS HEIGHTS BOTTOM OF LOWEST STRUCTURE:11'-0" A.F.F. BOTTOM OF ROOF DECK:14'-0" A.F.F. @ WEST 12'-8" A.F.F. @ EAST BOTTOM OF TYP. STRUCT. JOIST 12'-2" A.F.F. @ WEST 11'-0" A.F.F. @ EAST BOTTOM OF LOWEST OBSTRUCTION 10'-5" A.F.F. (EXIST. RTU DROP) 4' - 0 " TY P I C A L P1 101A 1 TYP. 101B 010203 04 05 06 10 7 0708 09 10 9 10 8 10 11 0 B 110 A 111 11 12 14 13 15 113 16 17 18 20 19 21 22 23 24 25 W- 2 W- 1 W-1W-1 W- 3 W- 3 W- 3 6'-0" PROPOSED FUTURE WALL KNOCK-OUT SEE DETAIL 8/A6.1 10 1/2"14'-0 3/4"±4'-7"13'-6"13'-6"13'-6"13'-6"13'-5 1/4"13'-0 1/4"1'-0 3/4" ALIGN AL I G N ALIGN 10 ' - 5 " 12 ' - 5 1 / 2 " 6' - 0 " CL E A R / H O L D 13 ' - 3 5 / 8 " 3' - 7 " 4'-0 3/4" 11'-10"9'-5 1/2"10'-5"4'-3 3/4" 10 ' - 7 3 / 4 " 10'-2"6'-3"10'-10 1/2"7'-8 1/2"7'-7"5'-1"10'-11" 2' - 5 1 / 4 " ± 9' - 0 " 10 ' - 3 " 10 ' - 3 " 11 ' - 1 1 " 9' - 3 3 / 4 " ± 10 1 / 2 " 10'-11"4'-2"14'-2"13'-7"10'-5"10'-5"11'-3"7'-1 1/2"4'-6"8'-5" 6'-1 1/4" 2' - 6 " 2' - 1 0 " 2' - 1 0 " 3' - 7 " 4' - 1 0 " 4' - 2 1 / 2 " 9' - 5 " 4' - 2 " 12 ' - 1 0 3 / 4 " 11 ' - 1 0 1 / 2 " 4' - 2 " 3' - 0 " 5'-10" 2'-10"5'-6"5'-5" 3'-6" 5' - 0 " 2' - 4 " 7'-2 3/4" CLEAR/HOLD 18" HOLD 18 " MI N . 4'-2"5'-10" 3' - 6 " 5' - 1 0 " 3'-6" 4"3'-0" 5' - 1 0 " 3'-6" 3"1'-1"1'-1" 4" TYP. 7" TY P . 4" TYP. 3'-0"7" TYP. 3'-0"4'-0" 3'-5"4'-0" 6'-2" 6' - 0 " PR O P O S E D F U T U R E WA L L K N O C K - O U T SE E D E T A I L 8 / A 6 . 1 6' - 0 " PR O P O S E D F U T U R E WA L L K N O C K - O U T SE E D E T A I L 8 / A 6 . 1 6' - 0 " PR O P O S E D F U T U R E WA L L K N O C K - O U T SE E D E T A I L 8 / A 6 . 1 6' - 0 " PR O P O S E D F U T U R E WA L L K N O C K - O U T SE E D E T A I L 8 / A 6 . 1 6'-0" PROPOSED FUTURE WALL KNOCK-OUT SEE DETAIL 8/A6.1 4' - 0 " TY P I C A L 4' - 0 " TY P I C A L 18" MIN. P7 5' - 0 " 4' - 8 " 1' - 1 0 " P1P1 P1 P2P1 P5 P7 P5 P6 P5 P5P4 P3P1 P3 P1 P3 P3 P2 P1 P1 P2 P1 P1 P1 P2 P1 P2 P1 P1 P1 P1 P1 P2 P2 P1 P7 P1 P2P1P2 P1 P1 P1P2 P1P2P1 P1 7'-4"3" P3 4" STUD 58 88 8 8 4 1 TYP. 1 TYP. 1 TYP. 1 TYP.1 TYP.1 TYP. 1 TYP. 23 4 6 7 9 4' - 2 " P2 P5 EXI S T . EXI S T . EXI S T . 3' - 8 " MI N . EXISTING COMMON EXIT CORRIDOR EXISTING BUILDING UTILITY ROOM SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N N DIMENSION FLOOR PLAN A2.0 1 A2.0 3/16"=1'-0" DIMENSION FLOOR PLAN 2 A2.0 6"=1'-0" TYPICAL WALL BASE DETAIL 3 A2.0 3"=1'-0" ALUMINUM HEAD DETAIL EXIST. WALLS TO REMAIN. G.C. TO PATCH & REPAIR EXIST. AS REQ'D. TO 'LIKE NEW' FINISH. NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD. ON EA. SIDE OF 3 5/8"(U.N.O.) MTL. STUD FRMG. @ 24" O.C. FROM FINISH FLOOR TO 9'-6" A.F.F. NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD. ON EA. SIDE OF 3 5/8"(U.N.O.) MTL. STUD FRMG. @ 16" O.C. FROM FINISH FLOOR TO 9'-6" A.F.F. NON RATED PARTITION: (1) LAYER 5/8" GYP. BD. ON EA. SIDE OF 3 5/8"(U.N.O.) MTL. STUD FRMG. @ 24" O.C. W/ 3 1/2" FIBERGLASS SOUND BATT INSUL. FROM FINISH FLOOR TO B.O. ROOF DECK. NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD. ON EA. SIDE OF 6" MTL. STUD FRMG. @ 16" O.C. W/ 3 1/2" FIBERGLASS SOUND BATT INSUL. FROM FINISH FLOOR TO B.O. ROOF DECK. NON-RATED PARTITION:(2) LAYERS 5/8" GYP. BD. (TYPE VARIES) ON EA. SIDE OF 6" MTL. STUD FRMG. @ 24" O.C. W/ 5 1/2" FIBERGLASS SOUND BATT INSUL. FROM FINISH FLOOR TO B.O. ROOF DECK. SEE 12/A6.1 FOR CONSTRUCTION. NON-RATED PARTITION:(2) LAYERS 5/8" GYP. BD. (TYPE VARIES) ON EA. SIDE OF 6" MTL. STUD FRMG. @ 16" O.C. W/ 5 1/2" FIBERGLASS SOUND BATT INSUL. FROM FINISH FLOOR TO B.O. ROOF DECK. SEE 12/A6.1 FOR CONSTR. NON-RATED PARTITION: (1) LAYER 5/8" GYP. BD. ON 3 5/8"(U.N.O.) MTL. STUD FRMG. @ 16" O.C. FROM FINISH FLOOR TO 9'-6" A.F.F. P3 P1 PARTITION LEGEND P2 P4 PARTITION NOTES 1.NOTHING IS PERMITTED TO BE ATTACHED, SUSPENDED, OR PENETRATE THE ROOF DECK ABOVE. FRAME, BRACE, &/OR SUSPEND AS NEEDED FROM THE TOP CHORD OF JOISTS OR STRUCT. STEEL WHICH EXISTS ABOVE SPACE. 2.ALL LIGHT GAUGE METAL WALL STUDS SHALL BE 20 GA. MIN., U.N.O. SEE 1/A6.3 FOR STUD GAUGE LIMITING HEIGHTS & TYP. FRMG. NOTES. 3.USE W.R. GYP. BD. ADJACENT TO PLUMBING FIXTURES. 4.G.C. TO ENSURE WALL TO FLOOR TRANSITION IS STRAIGHT, TRUE, & READY TO RECEIVE BASE AS SCHEDULED. 5.ALL WALLS WITH MOUNTED CABINETS TO BE FRAMED WITH METAL STUDS AT 16" O.C. ALL OTHER WALLS TO BE FRAMED WITH METAL STUDS AT 24" O.C. VERIFY LOCATIONS AND WALL TYPES WITH PLANS. 6.SEE DETAILS 2/A6.3, 3/A6.3 & 4/A6.3 FOR TYPICAL FRAMING & FINISHES AT THE TOP OF WALLS. 7.HOLD GYP. BD. OFF FLOOR SLAB 1/4" MAX. THROUGHOUT SPACE. SEE DETAIL 2/A2.0. P6 DIMENSION KEY NOTES EXTEND EXIST. MTL. STUD FURRING & GYP. BD. TO DECK ABOVE ALONG ENTIRE LEASESPACE PERIMETER WHERE NONE IS PROVIDED. EXISTING FURRING & GYP. BD. @ STRUCTURAL COLUMN TO REMAIN. EXTEND TO 9'-6" A.F.F. MIN. (IF NOT ALREADY). SEE DETAIL 4/A6.3. FURR OUT AROUND EXIST. STRUCT. COLUMN W/ MTL. STUD FRAMING & GYP. BD. AS REQ'D. FURRING TO EXTEND FROM FINISHED FLOOR TO 9'-6" A.F.F. SEE DETAIL 4/A6.3. FURR OUT AROUND EXIST. STRUCT. COLUMN WITH MTL. STUD FRAMING & GYP. BD. AS REQ'D. FURRING TO EXTEND FROM FINISHED FLOOR TO BOTTOM OF ROOF DECK. SEE DETAILS 3/A2.0 & 2/A6.1 FOR LOCATING ALUM. GLAZING SYSTEM & WALL ABOVE. EXHAUST GRILLE TO BE CENTERED ON NAIL CABINET. COORD. METAL STUD FRAMING LAYOUT WITH DETAIL 5/A4.2 TO ENSURE EXHAUST GRILLE LOCATION IS MAINTAINED. COORD. PEDI-SPA & EXHAUST GRILLE LOCATIONS WITH DETAIL 2/A2.3. METAL STUD FRAMING LAYOUT TO ENSURE EXHAUST GRILLE LOCATION IS MAINTAINED AT PEDI-SPA. WORK POINT: DIM. TO OUTSIDE CORNER OF GYP. BD. HEADER ABOVE GLASS CORNER. HOLD WALL FRAMING OFF EXISTING DEMISING WALL 1". 1 2 3 4 P5 P7 5 6 7 8 9 GRID 63 ' - 6 3 / 4 " LE A S E L I N E T O L E A S E L I N E 101'-0 1/2" LEASELINE TO LEASELINE 3'-8 1/4" GRID GRID GRID 01020305 04 06 07 107 08 0910 108109 111 11 12 14 15 13 16 17 19 18 20 21 22 23 24 25 101 102103 104 105 106 110 112 113 114 FE FE FE A2.2 1 A6.0 4 A6.3 9 A6.1 2 A6.1 11 A6.1 6 A6.1 8 A4.0 2 TYP. 101A 101B 01 0203 04 05 06 10 7 0708 09 10 9 10 8 10 11 0 B 110 A 111 11 12 14 13 15 113 16 17 18 20 19 21 22 23 24 25 W- 2 W- 1 W-1W-1 W- 3 W- 3 W- 3 TYP.A6.2 2 TYP.24TYP.22 A4.0 10 A4.0 7 A4.0 3 A4.0 4 A4.2 5 A4.2 6 A4.0 6 A4.0 9 A4.0 8 A4.0 11 A4.1 2 A4.1 1 A4.1 3 A4.1 4 A4.2 4 A4.2 2 A4.2 1 A4.2 3 A6.2 1 A6.2 1 A4.0 1 TYP. A4.0 1 TYP.A4.0 1 TYP.A4.0 1 TYP.A4.0 1 TYP. A4.0 1 TYP. A6.0 4 A6.1 9 A6.1 9 A6.0 1 A6.1 9 A6.0 4 A6.0 1 A6.0 1 A6.0 1 A6.0 1 A6.0 1 A6.0 1 A6.0 1 A6.0 7A6.0 1 A6.0 1 A6.0 1 A6.1 9A6.0 1 A6.1 8 A6.1 8 A6.1 8 A6.1 8 A6.1 8 A1.2 3 A1.2 1 A1.2 2 A6.1 11 A6.1 11 A6.1 11 A6.1 11 A6.4 3 A6.4 3 A6.4 3 SIM. A6.1 6 SIM.A6.1 6 SIM. TYP.A6.2 2 TYP.22TYP.24 A6.1 6 SIM.A6.1 6 SIM.A6.1 6 SIM. 1 2 7 1 2 1 2125 1 2 1 2 31 1 3 31 4 4 5 5 7 5 5 5 57 7 8 5 7 6 888888 8 7 7 7 9 TYP. 9 TYP.9 TYP.9 TYP.9 TYP.9 TYP.9 TYP. 9 TYP. 9 TYP. 9 TYP. 9 TYP. 10 10 10 111720 14 19 18 15 13 12 16 21 21 23 23 24 24 272525 25 25 26 26 26 2626 26 26 26 26 26 26 26 26 26 26 2626 26 2626 26 26 26 26 28 29 3010 31 32 25 A6.2 7 A6.3 7 29 6 A6.1 6 1 3 A6.1 12 SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N FLOOR PLAN A2.1 1 A2.1 3/16"=1'-0" FLOOR PLAN - 4,906 S.F. N FLOOR PLAN KEY NOTES LEASELINE EXTERIOR OF BUILDING. INTERIOR WALL PARTITION / DEMISING WALL. PROTECT FROM DAMAGE DURING DEMOLITION AND CONSTRUCTION. REPAIR AS REQUIRED TO 'LIKE NEW' CONDITION. EXISTING CONCRETE SIDEWALK TO REMAIN. PROTECT FROM DAMAGE DURING DEMOLITION & CONSTRUCTION. PATCH, REPAIR, OR REPLACE ANY AREAS DAMAGE DURING CONSTRUCTION TO 'LIKE NEW' CONDITION. EXISTING ALUMINUM/GLASS STOREFRONT GLAZING SYSTEM TO REMAIN. PROTECT FROM DAMAGE DURING DEMOLITION & CONSTRUCTION. EXISTING EXTERIOR STOREFRONT BUILD-OUT WITH SOFFIT ABOVE. PROTECT FROM DAMAGE DURING DEMOLITION & CONSTRUCTION. NEW ALUMINUM / GLASS STOREFRONT GLAZING SYSTEM AS SCHEDULED. G.C. IS RESPONSIBLE FOR ALL STOREFRONT REPAIR NEEDED. SEAL, GASKET, REMOVE MAILBOXES, ETC. TO EXISTING TO REMAIN. LINE OF SILL BELOW WINDOWS. DASHED LINE INDICATES FLOATING GYP. BD. CEILING ABOVE, SEE REFLECTED CEILING PLAN. PROVIDE 2'x4' FIRE-RATED PLYWOOD BACKING FOR TELEPHONE BOARD & EQUIPMENT @ UTILITY ROOM. COORD. FINAL LOCATION OF TENANT'S PHONE D-MARC ON SITE WITH OWNER. WASHER/DRYER UNIT WITH 4" DRYER VENT PIPE IN WALL BEHIND. SEE MECHANICAL PLANS. SERVICE SINK, SEE PLUMBING FOR DETAILS. PROVIDE WATER RESISTANT GYP. BD. AT AREA SURROUNDING SINK. 12" DEEP WOOD SHELVING ON METAL SUPPORT BRACKETS MOUNTED ON UTILITY ROOM WALL AT 6'-0" A.F.F. COORDINATE FINAL LOCATION W/ OWNER PRIOR TO CONSTRUCTION. TANKLESS HOT WATER HEATERS MOUNTED (BOTTOM AT MIN. 9'-0" ABOVE FINISHED FLOOR) TO INTERIOR PARTITION WALL. PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING FOR ATTACHMENT ON WALLS AS REQ'D. SEE ELEC. & PLUMBING PLANS FOR DETAILS. HOT WATER STORAGE TANK HUNG FROM STRUCTURE ABOVE. SEE PLUMBING PLANS. ELECTRICAL SERVICE PANELS, SEE ELECTRICAL FOR DETAILS. UTILITY TRASH CAN TO BE SUPPLIED AND INSTALLED BY SALON LOFTS. LADDER HANGER TO BE SUPPLIED AND INSTALLED G.C. COORDINATE FINAL LOCATION & MOUNTING HEIGHTS WITH SALON LOFTS. PROVIDE SURFACE MOUNT FIRE EXTINGUISHER AT LOCATIONS INDICATED. CLASS B,C SIZE 10. VERIFY FINAL LOCATIONS AND QUANTITIES WITH LOCAL FIRE MARSHALL. PROVIDE SEMI-RECESSED FIRE EXTINGUISHER CABINET & FIRE EXTINGUISHER AT LOCATIONS INDICATED. CLASS B,C SIZE 10 EXTINGUISHER. VERIFY FINAL LOCATIONS AND QUANTITIES WITH LOCAL FIRE MARSHALL. STYLIST STATION CASEWORK FIXTURES TO BE INSTALLED W/ ONE SIDE TIGHT TO ADJACENT WALL PARTITION AS SHOWN TYP., UNLESS NOTED OTHERWISE, COORDINATE WITH PLAN. PROVIDE FINISHED P.LAM. EDGES/SURFACES ON CASEWORK WHERE EXPOSED TO VIEW. CASEWORK CABINETS, SEE A6.2 FOR DETAILS, MOUNTED WITH BOTTOM OF CABINET @ 4'-0" A.F.F. PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING AS REQUIRED FOR ATTACHMENT OF CASEWORK ITEMS. PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING IN WALL AS REQUIRED FOR ATTACHMENT OF CASEWORK / MILLWORK ITEMS. WOOD FRAMED MIRROR, PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING AS REQUIRED. SEE INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS & ORIENTATION. (2) COAT HOOKS MOUNTED @ 5'-0" A.F.F. (SPACED @ 8" O.C.). PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING IN WALL AS REQUIRED. VERIFY FINAL LOCATION WITH SALON LOFTS' REPRESENTATIVE ON SITE PRIOR TO INSTALLATION OF BACKING. NAIL LOFT SINK, SEE 6/A2.2 FOR DETAILS. FREESTANDING PEDI-SPA. SEE DETAIL 2/A2.3. DOOR CHIME. DOOR BUTTON @ ENTRY DOOR W/ CHIME LOCATED ABOVE CEILING IN WAITING #103. InterlockingRock PANELS OVER GYP. BD. WALL SURFACE. INSTALL PER MANUFACTURER'S INSTRUCTIONS. SEE ELEVATIONS FOR ADDITIONAL INFORMATION. COORD. W/ SALON LOFTS' REPRESENTATIVE ON SITE. InterlockingRock BLOCK WALL (3 BLOCKS WIDE / 3 BLOCKS HIGH). INSTALL PER MANUFACTURER'S INSTRUCTIONS. SEE ELEVATIONS FOR ADDITIONAL INFORMATION. COORDINATE REQUIRED STIFFENERS WITH SALON LOFTS' REPRESENTATIVE ON SITE. ILLUMINATED SALON LOFTS PUCK & GRAPHICS PANEL. PROVIDE 3/4" FIRE-RATED PLYWOOD BACKING IN WALL AS REQ'D. SEE INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS. 1 2 3 4 5 6 7 8 17 18 19 20 21 22 23 24 25 26 27 28 29 30 9 10 11 12 14 15 16 13 31 32 ACCESSIBLE SOAP DISPENSER S.D. ACCESSIBLE MIRROR @ VANITY COUNTER MI.MOUNT MIRROR @ 40" A.F.F. MAX.- COORD. MOUNTING HEIGHT WITH VANITY COUNTER DTL. HINGE APPROACH LATCH APPROACH FRONT APPROACH EXCEPTION - 12" IS NOT REQUIRED UNLESS DOOR HAS BOTH A CLOSER AND A LATCH NOTE - ALL DOORS IN ALCOVES SHALL COMPLY WITH THE CLEARANCE FOR FRONT APPROACHES TO O F S I G N TY P F O R A L L AC C E S S S I G N S ACCESSIBLE LAVATORY/MIRROR COORDINATE MOUNTING HEIGHT WITH MIRROR LOCATION MI. LAV. ACCESSIBLE HI-LO DRINKING FOUNTAIN ACCESSIBLE P.T.D. / WASTE RECEPTACLE P.T.D. TOWEL SLOT ACCESSIBLE SIGNAGE 3' - 4 " M A X . TO R E F L E C T I O N SU R F A C E 2' - 3 " M I N . 2' - 5 " M I N . 2' - 1 0 " M A X . T O T H E R I M COORDINATE MOUNTING HEIGHT WITH MIRROR LOCATION LAV. ACCESSIBLE LAVATORY 9" M I N . 2' - 3 " M I N . 2' - 5 " M I N . 1'-5" 6" MAX.8" 2' - 1 0 " M A X . T O T H E R I M 9" M I N . 2' - 3 " M I N . 1'-5" MIN. 11" MIN. 8" MIN. 36 " M A X . 42 " - 4 8 " SP O U T H G T ' S . 12" MIN. 4" M I N . 4' - 6 " M A X . S I D E A P P R O A C H 4' - 0 " M A X . F R O N T A P P R O A C H 5' - 0 " 4' - 6 " M A X . SI D E A P P R O A C H 3' - 1 0 " M A X . OR O B S T R U C T I O N OV E R C O U N T E R 4' - 1 0 " M A X . FR O N T A P P R O A C H 3' - 4 " M A X . TO R E F L E C T I O N SU R F A C E 3'-0" MIN. 3'-6" MIN. 4'-6" MIN. 3' - 6 " M I N . (4 ' - 0 " M I N . W / BO T H L A T C H & C L O S E R ) 5' - 0 " MI N . 4' - 6 " MI N . 2'-0" MIN. 2'-0" MIN. 3' - 6 " M I N . (4 ' - 0 " M I N . W / CL O S E R ) 4' - 0 " M I N . (4 ' - 6 " M I N . W / CL O S E R ) 4' - 0 " MI N . 5' - 0 " MI N . 18" MIN. 12" MIN. NOTE: ACCESSIBILITY DETAILS DESIGNED TO BE IN ACCORDANCE WITH THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. CLEAR FLOOR SPACE AT WATER CLOSET (FRONT APPROACH)ACCESSIBLE URINAL TO RIM URINAL TO CONTROLS 1' - 5 " 3' - 8 " M A X . NOTE: DETAILS SPECIFIC TO PROJECT WITHIN BALANCE OF CONSTRUCTION DOCUMENTS OVERRIDE DETAILS BELOW WHERE APPLICABLE. 42" MIN.1'-6" 56 " M I N . 60" MIN. CLEAR FLOOR SPACE G.B. 1 G.B. 2 W.C. CLEAR FLOOR SPACE AT WATER CLOSET (FRONT APPROACH) G.B. 1 W.C.W.C. G.B. 2 T.P.H. ACCESSIBLE WATER CLOSET ACCESSIBLE WATER CLOSET 33 " - 3 6 " 19 " M I N . 17 " - 1 9 " 1'-6" 33 " - 3 6 " 17 " - 1 9 " 3'-0" MAX. 7"-9" 54" MIN. 2" M I N . 15 " MI N . GRAB BAR GRAB BAR NUMBER LENGTH (<) GB1 3'-0" GB2 3'-6" GB3 1'-6" G.B. 3 12"12" G.B. 3 TOWEL SLOT P.T.D. ACCESSIBLE P.T.D. 4' - 6 " M A X . S I D E A P P R O A C H 4' - 0 " M A X . F R O N T A P P R O A C H G.B. W.C. LAV. PL-1 PROVIDE AND INSTALL A.D.A. COMPLIANT TRAP WRAP INSULATION (WHITE IN COLOR). 8' - 0 " EQ.EQ. SURFACE MOUNTED LIGHT FIXTURE 4' - 6 " 3 F U L L T I L E S CUT TILE IN CORNER W.C. G.B. C3 CASEWORK CABINETRY- SEE 11/A6.2 FOR DETAILS. B.O. AT 4'-0" A.F.F. T1 P4 T1 4' - 6 " 3 F U L L T I L E S P5 ADD CONCEALED SPACERS BEHIND MIRROR ABOVE TILE SO MIRROR IS PLUMB AT TILE & WALL. T.P.H. INSTALL CONCEALED SPACERS AT VERTICAL GRAB BAR AS REQ'D. T.P.H. MI. P.T.H.- ALIGN T.O. DISPENSER W/ T.O. TILE & CENTER ON TILE (VFY.). 6" 4' - 6 " 3 F U L L T I L E S START WITH FULL WALL TILE AT CORNER / WALL EDGE. VERIFY LOCATIONS WITH PLANS & ELEVATIONS, TYP. B4 P4 CUT TILE VERIFY F1 P4/P5 VERIFY TILE JOINTS OF BASE TILE MUST ALIGN WITH TILE JOINTS ON FLOOR, TYP. SATIN ALUMINUM (AE) TILE EDGE TRIM- SCHLUTER SCHIENE, TYP. AT ALL EXPOSED TILE EDGES. SEE PLANS, ELEVATIONS & TOILET ROOM DETAILS FOR MORE INFORMATION. SATIN ALUMINUM (AE) TILE EDGE TRIM- SCHLUTER SCHIENE, TYP. AT ALL EXPOSED TILE EDGES. T1 6" HIGH BASE AT TOILET ROOMS. 4" HIGH BASE AT ALL OTHER LOCATIONS SCHEDULED U.N.O., TYP. B4 B3 CUT TILE IN CORNER START FULL TILE START FULL TILE 109 10 9 A2.2 3 A2.2 2 A2.2 5 T.P.H.G.B.(42") W.C. G.B.(36") P. T . D . LAV. MI. REV. 1' - 6 " 3' - 0 " ± 5'- 0 " MIN . 1' - 6 " 1'-1" G.B.(18") (VERT.) B4 F1 C3 CASEWORK CABINETRY- SEE 11/A6.2 FOR DETAILS. B.O. AT 4'-0" A.F.F. U.S. JOINTS OF THE BASE FINISH TO ALIGN WITH THE FLOOR FINISH, TYP. SEE DETAIL 8/A2.2 FOR MORE INFORMATION. START WITH FULL FLOOR TILE AT THE DOOR CORNER, VERIFY. 48"x48" 5" 8' - 0 " 5" 5"7'-0"7"7'-0"8 1/2" 48"x30" 60"x54" 56"x60" 108 10 8 A2.2 3 A2.2 2 A2.2 5 T.P.H.G.B.(42") W.C. G.B.(36") P. T . D . LAV. MI. 1' - 6 " 3' - 0 " ± 5 ' - 0 " M I N . 1' - 6 " 1'-1" G.B.(18") (VERT.) B4 F1 C3 CASEWORK CABINETRY- SEE 11/A6.2 FOR DETAILS. B.O. AT 4'-0" A.F.F. U.S. JOINTS OF THE BASE FINISH TO ALIGN WITH THE FLOOR FINISH, TYP. SEE DETAIL 8/A2.2 FOR MORE INFORMATION. START WITH FULL FLOOR TILE AT THE DOOR CORNER, VERIFY. 48"x48" 48"x30" 60"x54" 56"x60" REV. WALL PARTITION AS SCHED. SEE A2.0 FOR ACTUAL WALL ORIENTATION. WATER SUPPLY & WASTE PIPING TO BE STUBBED AT WALL LOCATION AS SHOWN DASHED. PLUMBING CONTRACTOR TO COORDINATE FINAL LOCATIONS W/ FIXTURE CUT SHEETS. 10 3 / 4 " VF Y . PLAN VIEW DETAIL ELEVATION VIEW DETAIL STAINLESS STEEL DECORATIVE BAR BELOW. TEMPERED GLASS LAVATORY BOWL. GLASS LAVATORY SHELF BELOW. STAINLESS STEEL FAUCET FIXTURE AS SCHEDULED. STAINLESS STEEL VANITY BELOW. 34 " M A X . TO R I M O F B O W L STAINLESS STEEL DECORATIVE BAR BELOW. TEMPERED GLASS LAVATORY BOWL. GLASS LAVATORY SHELF BELOW. STAINLESS STEEL FAUCET FIXTURE AS SCHEDULED. PLUMBING CONTRACTOR TO STUB WATER SUPPLY & WASTE PIPING AS REQ'D. PER MFR.'S RECOMMENDATIONS. COORD. FINAL LOCATIONS W/ FIXTURE CUT SHEETS. 4" 1'-1" 1 3 / 8 " 8" PL-1 PL-1 WOOD FRAMED MIRROR AS SCHEDULED. 4" HIGH PLASTIC LAMINATE BACKSPLASH . PLASTIC LAMINATE FINISH ON VANITY COUNTER . SEMI-COUNTERTOP SINK- SEE PLUMBING PLANS. NOTE: PROVIDE FINISHED END PANEL AT OPEN END OF VANITY COUNTER. PROVIDE A.D.A. COMPLIANT TRAP WRAP INSULATION (WHITE IN COLOR). 2' - 1 0 " M A X . T O R I M VE R I F Y SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N N TOILET ROOM LEGEND W.C.FLOOR SET TANK STYLE WATER CLOSET. FLUSH CONTROLS TO BE LOCATED ON ACCESSIBLE SIDE OF FIXTURE. SEE PLUMBING PLANS. LAV.DROP-IN BOWL STYLE LAVATORY SET IN COUNTERTOP WITH A.D.A. COMPLIANT FAUCET. PROVIDE AND INSTALL A.D.A. COMPLIANT TRAP WRAP INSULATION (WHITE IN COLOR). SEE PLUMBING PLANS. MI.WOOD FRAMED WALL MIRROR. SET WOOD FRAMED MIRROR IMMEDIATELY ABOVE VANITY BACKSPLASH. REFLECTIVE SURFACE OF MIRROR SHALL BE NO HIGHER THAN 3'-4" A.F.F. CENTER MIRROR ON LAVATORY SINK. G.B.STAINLESS STEEL HANDICAP COMPLIANT GRAB BARS PER CODE. LENGTHS NOTED ON PLAN. T.P.H.WALL MOUNTED TOILET PAPER HOLDER (MULTI-ROLL). BOBRICK B-2888 SERIES. P.T.H.SURFACE MOUNTED C-FOLD PAPER TOWEL DISPENSER. BOBRICK B-2620. U.S.UNISEX TOILET ROOM SIGNAGE. PLASTIC SIGN INDICATING ACCESSIBILITY. SELF-ADHERED. SEE SHEET A0.3 FOR DETAILS. LAVATORY NOTE: LAVATORIES SHALL HAVE A CLEAR ACCESS WIDTH OF NOT LESS THAN 30", CLEAR HEIGHT OF NOT LESS THAN 29" TO THE BOTTOM OF THE FIXTURE APRON, CLEAR HEIGHT OF NOT MORE THAN 34" TO THE RIM OF THE FIXTURE, & A CLEAR DEPTH OF NOT LESS THAN 12" UNDER THE FIXTURE EXCLUSIVE OF THE BOWL & WASTE PIPE. ALL EXPOSED PIPES ARE TO BE COVERED WITH AN INSULATED PROTECTIVE MATERIAL. THE WATER CONTROL VALVES SHALL HAVE LEVER HANDLES. RESTROOM ACCESSORIES NOTE: ALL FIXTURES & ACCESSORIES TO MEET ACCESSIBILITY REQUIREMENTS, SEE DETAIL 4/A2.2. MIRRORS SHALL BE MOUNTED SO THAT THE BOTTOM IS NO HIGHER THAN 40" ABOVE THE FLOOR. ALL WALL-MOUNTED DISPENSERS, WASTE, DISPOSAL CONTAINERS, OR SIMILAR ACCESSORIES SHALL BE MOUNTED SO THAT WORKING HEIGHT IS NO HIGHER THAN 48" ABOVE THE FLOOR FOR A FRONT APPROACH AND NO HIGHER THAN 54" ABOVE THE FLOOR FOR A SIDE APPROACH, AND SHALL BE FREE OF INTERFERENCE BY GRAB BARS OR OTHER ACCESSORIES OR FIXTURES. GRAB BARS SHALL SUPPORT A WEIGHT OF 250 LBS. OR GREATER. RESTROOM FINISHES NOTE: SHALL BE INSTALLED 4'-6" HIGH ON WALLS ADJACENT TO WATER CLOSET. TILE TO BE INSTALLED IN FULL TILE INCREMENTS STARTING WHERE INDICATED ON ELEVATIONS. ALL OTHER WALLS TO HAVE A 6" HIGH BASE. SEE DETAIL 8/A2.2. T1 B4 TOILET ROOM PLAN, ELEVATIONS & ACCESSIBILITY A2.25 A2.2 1 1/2"=1'-0" VANITY COUNTER DETAIL 6 A2.2 1"=1'-0" NAIL SINK DETAILS 7 A2.2 NOT USED 8 A2.2 1/2"=1'-0" TYPICAL TILE LAYOUT DETAIL 4 A2.2 1/4"=1'-0" ACCESSIBILITY DETAILS3 A2.2 1/2"=1'-0" TOILET ROOM ELEVATION 2 A2.2 1/2"=1'-0" TOILET ROOM ELEVATION 1 A2.2 1/2"=1'-0" ENLARGED TOILET ROOM PLAN PEDI-SPA BY SALON LOFTS. F6 18" MIN. 1' - 0 " HUB DRAIN (LOCATE AS FAR TO THE REAR OF THE PEDISPA AS POSSIBLE BUT STILL TO BE CONCEALED) - SEE PLUMBING PLANS. VERIFY OUTLET LOCATION WITH ELECTRICAL PLANS. 2' - 0 " EXHAUST GRILLE IN WALL- PAINT TO MATCH WALL. VFY. LOCATION W/ SHEET A2.0 & MECH PLANS. LOCATE WATER LINES & OUTLETS IN WALL. WATER STUBS TO BE ELECTRICALLY BONDED. GRID GRID GRID GRID 01020305 04 06 07 107 08 0910 108109 111 11 12 14 15 13 16 17 19 18 20 21 22 23 24 25 101 102103 104 105 106 110 112 113 114 FE FE FE C7 F8 C12 C11 C10 F5 F4 F7 F20 F6 F3 C14 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 F19 C9C3 C15 F12 F23 C3 C4 C2 C16 F14 C2 F1 C1 C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2 C16 F14 C2 F1 C1 C5 C3 C4 C3 C4 C2C16 F14 C2 F1 C1C5 C3 C4 C3 C4 C2 C16 F14 C2 F1 C1 C5 C3 C4 C3 C4 C2 C16 F14 C2 F1 C1 C5 C3 C4 C3 C4 C2 C16 F14 C2 F1 C1 C5 C3 C4 C3 C4 C2 C16 F14 C2 F1 C1 C5 C3 C4 C3 C4 C2 C16 F14 C2 F1 C1 C5 C3 C4C5 C2 C3 C4 C1F1 C16 F14 C2 C3 C4 C5 C2 C3 C4 C1F1 C16 F14 C2 C3 C4 C5 C2 C3 C4 C1F1 C16 F14 C2 C3 C4 C5 C2 C3 C4 C1F1 C16 F14 C2 C3 C4 C5 C2 C3 C4 C1 F1 C16 F14 C2 C3 C4 C5 C2 C3 C4 C1 F1 C16 F14 C2 C3 C4 F19 C9C3 C15 C7 F8 C14 F23 F21 F21 F22 F9 F9 F9 F9 F10 C13 F5 C17 C5HORIZ. C5HORIZ. C5VERT.C5HORIZ. F12F12 F12 F12 F12 F10 F9F9 F12 F12 F12 F12 F12 F12 F12 F12 F12 F12HORIZ. SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N FURNITURE PLAN A2.32 A2.3 1/2"=1'-0" PEDI-SPA SECTION DETAIL N 1 A2.3 3/16"=1'-0" FURNITURE PLAN SATIN ALUM. (AE) TILE EDGE TRIM - SCHLUTER-SCHIENE. CARPET OVER SELF-LEVELING CEMENTITIOUS UNDERLAYMENT. ALIGN/FLUSH F1/F7VARIES ADA COMPLIANT FLUSH ALUM. THRESHOLD RAMP BY PEMKO OR APPROVED EQ. VERIFY FINAL ELEVATION OF CERAMIC TILE PRIOR TO ORDERING THRESHOLD SO AS TO MAKE A FLUSH TRANSITION. F1/F7 DOOR THRESHOLD / BUILDING EXTERIOR (VERIFY) GRID GRID GRID GRID 01020305 04 06 07 107 08 0910 108109 111 11 12 14 15 13 16 17 19 18 20 21 22 23 24 25 101 102103 104 105 106 110 112 113 114 FE FE FE CARPET TILE LAYOUT STARTING POINTS (SHOWN SHADED) ARE AS DIMENSIONED AT HALLWAYS '102' & '104'. T1 / P 5 P4 F1 B4 T1/P4 TYP. @ EDGES F1 NOTE: GENERAL CONTRACTOR SHALL VERIFY SALON LOFTS SUPPLIED FINISH MATERIAL QUANTITIES AS INDICATED ON SHEET A0.3 WITHIN 7 DAYS OF BEING AWARDED THE CONTRACT FOR CONSTRUCTION. SUBMIT FINAL VERIFIED QUANTITIES TO SALON LOFTS' REPRESENTATIVE. GENERAL CONTRACTOR ASSUMES RESPONSIBILITY FOR CHARGES RELATED TO FINISH MATERIAL SHORTAGES WHICH ANY/ALL WERE NOT VERIFIED & COORDINATED WITH SALON LOFTS' REPRESENTATIVE WITHIN THE TIME FRAME NOTED.F6 B1 P1 F1 B1 P1 F4 T1 3 TYP. A2.4 2 A2.4 3 6" 6"6"6"4"T1 P7/P1P7/P1P7/P1 P7/P1 P7/P1 P7 / P 1 P7 / P 1 P7/P1 P7/P1 P7/P1 P7/P1 P7/P1 P7/P1 T1 T1 P7 / P 1 P7/P1P7/P1P7/P1P7/P1 P7 P7 / P 1 P7 / P 1 P7/P1 P7/P1 P7 / P 1 P7/P1 P7/P1 P7/P1 P6 P6P6 5555 6 5 5 5 P6 P6 P6 P6 5 P6 5 P6 5 P6 5 P6 5 P6 5 P6 5 5 P6 P6 5 P6 5 P6 5 P6 5 5 P6 P6P6 5 5 P6 5 4"11 1/2"4'-0"2'-0"2'-0"2'-0"4" 1' - 1 " 11 " 11 ' - 6 3 / 4 " 2' - 0 " 1' - 6 " 4" 2' - 0 " 1' - 6 " 4" 4" TYP.1'-8 1/2"2'-0"12'-0"1'-9"2'-0"1'-6"4" 4" 1' - 6 " 4' - 0 " 12 " 4" F3 F3 F2 F2 1' - 6 3 / 4 " F2 1' - 5 1 / 4 " 4" 2' - 0 " 1' - 6 " 4" 55 4 1' - 1 0 1 / 2 " 1'-2" 4"2'-0"1'-6"4" 11 2 1 1 4" 1' - 6 " 1' - 1 0 " 4" 1 2 1 22 212 1 22 4" TY P . A6.4 4 A6.4 4 A2.4 2 4" P4 F1 B4 F1 B1 P1 F1 B1 P1 F1 B1 P1F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F1 B1 P1 F6 B1 P1 F6 B1 P1 TYP. @ EDGES F1 TYP. @ EDGES F1 T1 / P 5 T1/P4 F7 F2 F1 F2 F1 TYP. @ VESTIBULE PERIMETER3TYP. 3 TYP.3 TYP.3 TYP. 3 TYP. 8 TYP. 8 TYP. 8 TYP.7 TYP. 7 TYP. 7 TYP. 9 9 TYP.9 TYP.9 TYP. 9 TYP. 9 TYP. F5 B2 P1 2 F2 1010 22 7 TYP. SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N FINISH FLOOR PLAN A2.4 1 A2.4 3/16"=1'-0" FINISH FLOOR PLAN N FINISH KEY NOTES 1 2 3 4 FULL 24x24 CARPET TILE. PARTIAL CARPET TILE TO DIMENSIONS INDICATED. CUT TILE AS REQ'D. TILES WITHOUT STRAIGHT AND TRUE EDGES SHALL NOT BE ACCEPTED. BELOW 9'-6" A.F.F, WALL TO BE PAINTED PER PLANS. ABOVE 9'-6" A.F.F., WALL TO BE PAINTED , TYP. TILE JOINTS OF THE TILE BASE MUST ALIGN WITH THE TILE FLOOR JOINTS, TYP. SEE DETAIL 8/A2.2. START WITH FULL TILE AT DOOR ENTRY, SHOWN HATCHED. ALL OTHER TILE WITHIN ROOM BASED ON THIS START POINT. FLOORING EXTENDS TO SPA VESTIBULE THROUGH DOOR #107 TO ABUT FLOOR AT THRESHOLD. 4" CUT TILE FLOOR , TYPICAL AT HALLWAY PERIMETER. TILE JOINTS AT HALLWAY PERIMETER TILE DO NOT NECESSARILY ALIGN W/ JOINTS WITHIN LOFTS. SEE DETAIL 3/A2.4 FOR TYP. TRANSITION. AT CORNERS, TILE TO BE BUTT JOINTED AS INDICATED WITH THE SCHLUTER STRIP MITRED AND TIGHTLY JOINED SO THERE IS NO GAP. TOP OF SCHLUTER STRIPS FORMING CORNERS TO BE FLUSH. P.LAM. WINDOW SILL SUPPLIED & INSTALLED BY G.C. PAINT ALL EXPOSED SIDES OF GYP. BD. COLUMN ENCLOSURE TO 9'-6" A.F.F. PAINT EXPOSED STEEL COLUMN ABOVE 9'-6" A.F.F. . P2 5 6 7 F2 F6 1.FINISH ABOVE 9'-6" (VFY.) @ INTERIOR WALLS TO BE . SEE DETAIL 4/A6.3, TYP. 2.ALL GYP. BD. WALL/CEILING SOFFITS WITHIN CONSTR. AREA TO RECEIVE A SMOOTH PAINT FINISH, U.N.O. 3.ALL GYP. BD. WALL SURFACES TO BE FINISHED SMOOTH REGARDLESS OF FINISHES SCHEDULED. 4.G.C. TO PROVIDE SMOOTH FLOOR TRANSITIONS BETWEEN FINISHES SCHEDULED, FLASH SLAB, ETC. AS REQ'D. 5.G.C. TO APPLY PAINT AS REQ'D. PER MFR.'S SPECIFICATIONS. TWO COATS OF FINISH PAINT TO BE PROVIDED OVER PRIME COAT AT NEW CONSTRUCTION OR EXIST. PAINT AT EXIST. CONSTR. 6.TOUCH-UPS MAY REQUIRE REPAINTING ENTIRE SURFACE UNTIL CHANGE OF PLANE OCCURS IF VISIBLE. 7.G.C. TO PROVIDE A PROTECTIVE COATING AT ALL NEW FLOOR FINISHES AFTER INSTALLATION. 8.ALL FLOORING FINISHES SHALL BE OF CLASS I OR CLASS II MATERIALS IN ACCORDANCE WITH NFPA 253 AND INTERNATIONAL BUILDING CODE 804.1. TEST REPORT COPIES TO BE PROVIDED TO BLDG. OFFICIAL UPON REQUEST. 9.ALL INT. WALL, CEILING, & FLOOR FINISHES SHALL BE CLASS B OR CLASS C. CLASS B: FLAME SPREAD 26-75; SMOKE DEVELOPED 0-450 CLASS C: FLAME SPREAD 76-200; SMOKE DEVELOPED 0-450 10.ALL INTERIOR FINISHES TO BE ATTACHED SUCH THAT MATERIALS WILL NOT SEPARATE FROM SUBSTRATE WHEN SUBJECTED TO A ROOM TEMPERATURE OF 200°F FOR NOT LESS THAN 30 MINUTES. 11.SITE SURVEY REQUIRED BY FLOORING INSTALLER PRIOR TO BID. ALL FLOOR PREP SHALL BE INCLUDED IN THE BASE BID FOR THE PROJECT. 12.FULLY ADHERE CARPET TILES & BROADLOOM CARPET W/ MFR. RECOMMENDED ADHESIVE. NO ADHESIVE SHALL BE PLACED PAST EDGE OF CARPET TILES ONTO ADJACENT FLOOR SURFACE. THE 4" WIDE TYPICAL EXPOSED FINISH BETWEEN CARPET & WALL SHALL BE COMPLETELY FREE OF EXCESS ADHESIVES. 13.PAINT SYSTEMS: PROVIDE MIN. (2) COATS PLUS PRIMER SYSTEMS. A) GYPSUM BOARD WALLS (HALLWAYS): EGGSHELL LATEX EMULSION B) GYPSUM BOARD WALLS (LOFTS, TOILET RMS, UTILITY): EGGSHELL LATEX EMULSION C) INTERIOR PAINTED METAL: SEMI-GLOSS 100% ACRYLIC D) GYPSUM BOARD CEILINGS: FLAT LATEX EMULSION E) OPAQUE PAINTED WOOD: SEMI-GLOSS 100% ACRYLIC F) EXTERIOR PAINTED METAL: SEMI-GLOSS 100% ACRYLIC G) EXPOSED STRUCTURE CEILINGS, DUCTWORK, STRUTS, CONDUITS, WIRES, ETC: WATERBORNE ACRYLIC FLAT DRYFALL PRIMER/FINISH (ONE COAT SYSTEM) P2 FINISH GENERAL NOTES F1 PL-1 8 9 F1 F1 3 A2.4 6"=1'-0" CARPET-TILE TRANSITION2 A2.4 6"=1'-0" THRESHOLD DETAIL 10 P1 P2 GRID L L N MM A AA A A A A A A A A A A A A A AAA A A A BF F BF F BF F BF F BF F BF F BF F F F B F F B F F B F F B F F B F F B F F B F F B F F B FF B FF B FF B FF B FF B FF B E C2 C2 C2 C2 C2 C2 H (4'L) J X-2 DDDD DDD DDD D C1C1 KK G X-1 X- 1 X- 1 X-1 EM2 EM 2 X- 1 X- 1 X-1 X- 1 X- 1 X-1 X-2 X- 2 X-2 X-2 X- 2 GRID GRID GRID GGG X-1 X-1 X-2 X- 2 J X-1 H (4'L)H (1'L)H (4'L)H (1'L) E C2 C2 C2 C2 J 1'-11"2'-1"2'-1" 01020305 04 06 07 107 08 0910 108109 111 11 12 14 15 13 16 17 19 18 20 21 22 23 25 101 102 103 104 105 106 110 112 113 114 12 " 5' - 1 " A6.4 5 6" 8" 4' - 7 " 5' - 3 " 6" 6"3'-4 1/4"4'-0 1/4" 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 5'-1"12" 2' - 1 " 2' - 1 " 1' - 1 1 " 5'-1"12" 2' - 1 " 2' - 1 " 1' - 1 1 " 5'-1"12" 2' - 1 " 2' - 1 " 1' - 1 1 " 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 6" R2'-9" EQ.EQ. EQ . EQ . EQ.EQ. EQ . EQ . EQ.EQ. EQ . EQ . 3'-6"3'-6"3'-6"3'-6" 1' - 6 " 2' - 6 " 2' - 6 " 1' - 6 " 1' - 6 " 2' - 6 " 2' - 6 " 1' - 6 " 2' - 1 0 " 4' - 3 " 5'-3"5'-3" 1'-11"2'-1"2'-1" 2'-1"2'-1"1'-11" 12 " 4' - 4 " 12 " 5' - 1 " 1'-11"2'-1"2'-1" 12 " 5' - 1 " 2'-1"2'-1"1'-11" 5' - 1 " 12 " 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1' - 1 1 " 2' - 1 " 2' - 1 " 12"5'-1" 1'-11"2'-1"2'-1" 12 " 5' - 1 " A6.4 5 SIM. NOTE: PROVIDE ADDITIONAL CONCEALED BRACING TO ROOF STRUCTURE FROM FLOATING GYP. BD. CEILING IN ENTRY TO RESIST POSSIBLE UPLIFT / MOVEMENT FROM WIND PRESSURE. 9'-0" A.F.F. P3 2 4 9'-0" A.F.F. P3 2 6 9 6" 2' - 6 " 2' - 6 " 6" 6"2'-9"2'-1"8"6" 6' - 5 3 / 8 " 6' - 5 3 / 8 " R1' - 9 " 6"EQ.EQ. R2'- 9 " 2'-3"7'-6"16'-11 3/4"2'-1" 2' - 1 " 11 ' - 1 0 1 / 2 " 2' - 1 " 2'-1"18'-8"16'-3"2'-1" 5' - 8 " 14 ' - 1 1 / 2 " 11 ' - 1 1 / 2 " ALIGN ALIGN EQ. TYP. EQ. TYP. 4'-2"4'-4"3'-3 1/2"4'-4"6" EQ. TYP. EQ. TYP. EQ . TY P . EQ . TY P . 4'-7"16'-0"16'-0"8'-6"8'-10" EQ . TY P . EQ . TY P . EQ . TY P . EQ . TY P . A6.4 5 A6.4 5 R2'-3"R2'-3" 9'-0" A.F.F. P3 2 9'-0" A.F.F. P3 2 7'-9 3/4"15'-0"15'-0"15'-0" EQ . EQ . 9'-0" A.F.F. P3 113OPEN TO DECK, TYP. 3 OPEN TO DECK, TYP. P2 3 OPEN TO DECK, TYP. P2 3 OPEN TO DECK, TYP. P2 9'-0" A.F.F. ACT-1 9'-0" A.F.F. ACT-1 11 11 11 11 11 7 6 6 7 6 6 7 6 7 8 5 5 10 12 6 TYP. 6 TYP. 9" 1' - 3 " 2'-7" 2' - 6 " 2'-7" 2' - 6 " 2'-7" 2' - 6 " 2'-9" 2' - 6 " 2'-11" 2' - 6 " 2' - 5 " 3'-4" 3' - 2 " 2'-6" 1'-7" 3' - 2 " 4' - 4 " 2' - 1 0 " 13" 2' - 1 0 " 3'-9" 3' - 9 " 3' - 9 " 3' - 9 " 9'-5 3/4" 2'-5" 5' - 1 0 1 / 2 " 1' - 6 " 2'-1" 10 1/2" 7'-6" 6 TYP. 3'-10" 3'-10" 3'-10" 1' - 5 " 6 TYP. 6 TYP. 6 TYP. 6 8" 8 4 6'-7 1/2"4'-6" 3 OPEN TO DECK, TYP. P2 NO WORK REQ'D. NO WORK REQ'D. 14 6" 6' - 1 " 7" SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N REFLECTED CEILING PLAN A3.0 1 A3.0 3/16"=1'-0" REFLECTED CEILING PLAN N EM2 REFLECTED CEILING GENERAL NOTES 1.REFER TO ENGINEERING DRAWINGS FOR ELECTRICAL, LIGHTING AND HVAC WORK. COORDINATE ANY DISCREPANCIES WITH OWNER'S REPRESENTATIVE. 2.BACK TO BACK SWITCHES ARE NOT ALLOWED. OFFSET A MINIMAL DIMENSION WITH A METAL STUD IN BETWEEN OPPOSING SWITCHES OR HAVE ONE SET LOW/ONE HIGH. SEE ELECTRICAL PLANS. 3.SWITCHES SHOWN IN THE SAME LOCATION SHALL BE GANGED ON THE SAME COVER PLATE. 4.COORD. W/ ALL TRADES TO ENSURE CLEARANCES FOR ALL CEILING RELATED APPURTENANCES NECESSARY TO MAINTAIN THE SPECIFIED FINISH CEILING HEIGHT AS NOTED ON THE DRAWINGS. FIELD VERIFY PRIOR TO BID. 5.ALL LIGHT FIXTURES, HVAC EQUIP. & DIFFUSERS TO BE SUPPORTED FROM TOP CHORD OF STRUCT. JOIST ABOVE. 6.HANGER WIRE AT SUSPENDED CEILING (WHEN APPLICABLE) SHALL BE 8 GA., AND 10 GA. AT SUSPENDED A.C.T. WIRES SHALL BE ATTACHED TO STRUCT. STEEL ONLY, WITH U.L. LISTED CLAMPS. DO NOT ATTACH SUPPORT WIRES TO MECH. EQUIPMENT OR PIPING. SCREWS ARE NOT PERMITTED IN THE METAL DECKING. 7.CLG. SUSP. SYSTEM (AS REQ'D.) SHALL BE ATTACHED AT 2 ADJACENT WALLS, MAINTAIN 2 SIDES UNRESTRAINED. 8.PROVIDE ACCESS PANELS AS REQ'D. BY CODE. COORDINATE LOCATION W/ ARCHITECT. PROVIDE CEILING ACCESS TO ALL LANDLORD EQUIPMENT, CONTACT LANDLORD FOR REQUIREMENTS. REVIEW CEILING ACCESS REQUIREMENTS WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION OF ACCESS PANELS. COORDINATE ACCESS PANEL REQUIREMENTS WITH GATE SUPPLIER WHERE APPLICABLE. 9.REFER TO ELECTRICAL DRAWINGS FOR LIGHT FIXTURE SCHEDULE AND SPECIFICATIONS. 10.ALL CEILING HEIGHTS INDICATED ON PLANS ARE FROM TOP OF FINISH FLOOR TO UNDERSIDE OF FINISH CEILING. 11.ARCH. DRAWINGS DETERMINE THE LOCATION OF LUMINARIES & SUPERSEDES ALL OTHER DRAWINGS U.N.O. 12.ADDITIONAL HANGARS AND SAFETY WIRES FOR LIGHT FIXTURES, SPEAKERS AND AIR SUPPLY/RETURN DIFFUSERS (PER LOCAL CODES) TO BE THE RESPONSIBILITY OF THE CEILING SUB-CONTRACTOR. 13.ALL MEASUREMENTS ARE TO THE CENTER OF THE FIXTURE U.N.O. 14.ALL SPRINKLER HEADS IN FLOATING GYP. BD. CEILINGS TO BE WHITE CONCEALED TYPE, TYPICAL. REFLECTED CEILING PLAN KEY NOTES 1 2 3 4 5 6 P2 PAINTED SUSPENDED GYP. BD. CEILING (HGT. AS INDICATED) FLOATING GYP. BD. CEILING AS DIMENSIONED SUPPORTED FROM STRUCTURE ABOVE. SEE DETAIL 5/A6.4. OPEN TO DECK, TYPICAL UNLESS NOTED OTHERWISE . RECESSED JUNCTION BOX ABOVE VESTIBULE CLG. FOR CARD READER CONTROLLER SYSTEM TO INCLUDE: CONCEALED CONDUIT FROM 'J' BOX TO ROOF DECK ABOVE, CAT 5E CABLE FROM 'J' BOX TO TENANT'S NETWORK HUB DEVICE, AND 120V POWER. ALL TO BE PROVIDED BY ELECT. CONTRACTOR. G.C. SHALL COORDINATE WITH TENANT'S SECURITY VENDOR THEIR INSTALLATION AFTER ELECT. CONTRACTOR'S WORK IS COMPLETE. CONTACT SALON LOFTS FOR VENDOR. G.C. SHALL COORDINATE WITH TENANT'S MUSIC SYSTEM VENDOR FOR THEIR INSTALLATION. CONTACT SALON LOFTS FOR VENDOR. HVAC SUPPLY AIR DIFFUSER IN CEILING SYSTEM, SEE MECH. PLANS. COORD. FINAL LOCATIONS W/ LIGHTING, EXIST. STRUCT., & ACT. CLG. SYSTEM. CONTACT ARCH. IMMEDIATELY IF ANY DISCREPANCIES ARISE. EXHAUST FAN IN CEILING SYSTEM, SEE MECHANICAL PLANS. DOOR CHIME LOCATED ABOVE LIGHT COVE IN WAITING AREA #103 & HALLWAY #114. RECESSED GRAPHIC WITH HEAD ILLUMINATION. SEE 3/A6.1. ILLUMINATED SALON LOFTS PUCK & GRAPHIC PANEL WITH LED FLEX LIGHTS. G.C. TO COORDINATE REQUIREMENTS. SKYLIGHT AS INDICATED ON SHEET A1.1. PROVIDE UNI-STRUT & HANGERS FROM BOTTOM OF ROOF STRUCTURE TO SUSPEND LIGHTING WHERE NEW SKYLIGHTS ARE LOCATED, IF NECESSARY. InterlockingRock PANEL WALL WITH HEAD ILLUMINATION. SEE DETAIL 6/A6.4. OPEN TO DECK - NO FINISH REQUIRED THIS SPACE. SEE DETAIL 6/A6.4 FOR DETAIL AT FLOATING GYP. BD. CEILING EDGE, LIGHT FIXTURE, & InterlockingRock PANELS. LIGHT FIXTURE SCHEDULE NOTE: REFER TO ELECTRICAL DRAWINGS FOR FIXTURE & LAMPING SPECIFICATIONS. NOTE: CONTRACTOR IS RESPONSIBLE FOR ALL MOUNTING MEANS & METHODS, INCLUD. ALL APPROPRIATE BLOCKING. G K C1 F D X-1 PENDANT LIGHT FIXTURE W/ SHADE & WHITE CORD WHIP. CONTRACTOR TO PROVIDE & INSTALL WHITE CORD CAP- BOTTOM OF FIXTURE @ 7'-4" A.F.F. (NOTE: MOGUL ADAPTOR SHALL BE INSTALLED TIGHT TO B.O. THE TOP OF THE SHADE FRAME) 4'-0" TRACK W/ 3 LED HEADS. SUSPEND FROM STRUCT. ABOVE WITH SUPPORT & POWER FEED PENDANT MOUNTINGS PROVIDED. INSTALL TRACK @ 9'-0" A.F.F. RECESSED FLUORESCENT DOWNLIGHT WITH EMERGENCY BATTERY PACK. RECESSED MINI LOW VOLTAGE DOWNLIGHT- DIMMABLE 12" METAL HALIDE SUSPENDED DOWNLIGHT. B.O. FIXTURE @ 9'-6" A.F.F. (COORDINATE W/ EXISTING STRUCTURE HEIGHTS) 2'-0" x 4'-0" FLUORESCENT INDIRECT LAY-IN TYPE LIGHT FIXTURE WITH EMERGENCY BATTERY PACK. 3'-6" FLUORESCENT WALL FIXTURE. SURFACE MOUNTED VERTICALLY ADJACENT TO MIRROR @ 5'-10" A.F.F. TO CENTERLINE OF FIXTURE. SUSPENDED 1'-0" x 4'-0" FLUOR. LIGHT FIXTURE W/ EMERGENCY BATTERY PACK- CHAIN HANG FROM STRUCT. @ 10'-0"A.F.F. LED LINEAR WALL WASH FIXTURE. SEE DETAILS 3/A6.1 & 6/A6.4. DISPLAY W/ LINEAR LED FLEX. SEE 3/A4.2 & 5/A6.3. 2-6" FLUORESCENT WALL FIXTURE. SURFACE MOUNTED HORIZONTALLY ABOVE MIRROR @ 8'-0" A.F.F. TO CENTERLINE OF FIXTURE. 5'-0"Ø AIRCRAFT CABLE 4-POINT SUSPENDED FLUORESCENT FIXTURE. B.O. FIXTURE @ 9'-0" A.F.F. 4'-0"Ø AIRCRAFT CABLE 4-POINT SUSPENDED FLUORESCENT FIXTURE. B.O. FIXTURE @ 9'-0" A.F.F. 3'-0"Ø AIRCRAFT CABLE 4-POINT SUSPENDED FLUORESCENT FIXTURE. B.O. FIXTURE @ 9'-0" A.F.F. DECORATIVE OUTDOOR EMER. LIGHTING. COORD. MOUNTING HEIGHTS W/ LOCAL FIRE MARSHALL. LED EXIT DIRECTION AL LIGHT. COORDINATE MOUNTING HEIGHTS WITH LOCAL FIRE MARSHALL. FULLY WALL RECESSED COMPACT HALOGEN EMER. LIGHT. MOUNT AS INDICATED ON PLAN & ELEV. B L A X-2 C2 N E 7 8 9 10 11 M 12 H J 13 14 A6.1 1 MIRROR T1 TILE TO ALUM. FRAME JOINT SHALL BE CAULKED (NOT GROUTED) W/ CAULK TO MATCH GROUT. ALUM./GLASS DOOR FRAME. A6.1 2 T1 ABOVE DOOR IN VESTIBULE. T1 LINE OF TOP OF WALL BEYOND ABOVE DOOR IN VESTIBULE. LINE OF TOP OF WALL BEYOND FULL TILE SEE ELEVATION 9/A4.2 FOR MORE INFORMATION +0'-0" A.F.F. FINISH FLOOR B.O. ROOF DECK FIELD VERIFY THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LIGHT PER SCHED. P2 TYP. MIRROR SET FLUSH WITH WALL TILE. TILE TO ALUM. FRAME JOINT SHALL BE CAULKED (NOT GROUTED) W/ CAULK TO MATCH GROUT. ALUM./GLASS DOOR FRAME. A6.1 2 FULL TILE T1 LINE OF TOP OF WALL BEYOND ABOVE DOOR IN VESTIBULE. T1 A2.0 3 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LIGHT PER SCHED. P2 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK A2.0 3 P2 TYP. EXISTING GYP. BD. SURFACE UP TO DECK. PATCH & REPAIR AS REQ'D. TO RECEIVE NEW FINISHES SCHED. P2 P1 / P 6 VE R I F Y A6.3 4 WALLS TO BE PTD. PER PLANS. SEE SHEET A2.4, TYP. B1 P2TYP.TYP. B1 P1 TYP. 9' - 6 " VE R I F Y VE R I F Y RECESSED LIGHT COVE SHOWN DASHED. WALL GRAPHIC BY SALON LOFTS T1 BEYOND ABOVE DOOR A6.1 2 ALUM./GLASS STOREFRONT ENTRY SYSTEM BEYOND WITH DOOR. START TILE W/ FULL HEIGHT TILE @ FLOOR, TYP. T1 TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. SEE ELEVATION 7/A4.2 FOR MORE INFORMATION MILLWORK DISPLAY WALL W/ LED/LCD DISPLAY, ALL INSTALLED BY G.C. P1 B1 TYP. P1 P7 B1 TYP. TYP.P1 P7 B1 TYP. TYP. P1 P7 B1 TYP. TYP. P2BEYOND P2 BEYOND P2 BEYOND P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T 9' - 6 " TY P . W A L L H E I G H T P2BEYOND P2BEYOND 9' - 6 " TY P . W A L L H E I G H T TYP.A6.3 4 RECESSED FIRE EXTINGUISHER CABINET- CENTERED ON WALL. C5 WOOD FRAMED GLASS MIRROR (VERT.)- CENTER ON WALL. 3' - 0 " BO T T O M OF F R A M E FULL TILE 3 FULL TILESEQ.EQ. 9' - 0 " CE I L I N G H T . I N V E S T I B U L E FU L L TI L E 4 F U L L T I L E S FU L L TI L E PA R T I A L TI L E FULL TILE 3 FULL TILES EQ.EQ. 9' - 0 " CE I L I N G H T . I N V E S T I B U L E FU L L TI L E 4 F U L L T I L E S FU L L TI L E PA R T I A L TI L E END WALL OF HALLWAY # 104 BEYOND END WALL OF HALLWAY #105 BEYOND END WALL OF HALLWAY #102 BEYOND END WALL OF HALLWAY #114 BEYOND END WALL OF HALLWAY #104 BEYOND P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4.P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. WOOD FRAMED GLASS MIRROR (HORIZ.) BEYOND- CENTERED ON WALL. C13 TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. 3' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " 1'-6"1'-6" 4 FULL TILES FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK 6' - 4 " VE R I F Y 2' - 8 " VE R I F Y FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK TYP. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK SPA LOFT WALL UP TO DECK. P1 B1 P7 TYP. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. TYP.A6.3 4 M25InterlockingRock BLOCK BEYOND. PAINT (FLAT). RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" MILLWORK DISPLAY WALL W/ LED/LCD DISPLAY, ALL INSTALLED BY G.C. 9' - 6 " TY P . W A L L H E I G H T FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK T1 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. TYP.A6.3 4 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK TYP.A6.3 4 TILE EDGE RETURNS (1) FULL TILE WIDTH. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK 9' - 6 " TY P . W A L L H E I G H T TYP.A6.3 4 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. T1 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. SPA LOFT WALL UP TO DECK. 6" HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL.TYP. A6.3 4 A6.4 3 A6.4 3 SIM. 9' - 6 " TY P . W A L L H E I G H T P1 B1 P7 TYP. DOOR TRACK OVERHANGS TILE. DO NOT ATTACH THROUGH TILE. P3 END OF InterlockingRock BLOCK WALL. (FLAT).P3 P3 A6.1 1 MIRROR T1 TILE TO ALUM. FRAME JOINT SHALL BE CAULKED (NOT GROUTED) W/ CAULK TO MATCH GROUT. ALUM./GLASS DOOR FRAME. A6.1 2 T1 ABOVE DOOR IN VESTIBULE. T1 LINE OF TOP OF WALL BEYOND ABOVE DOOR IN VESTIBULE. LINE OF TOP OF WALL BEYOND FULL TILE SEE ELEVATION 9/A4.2 FOR MORE INFORMATION +0'-0" A.F.F. FINISH FLOOR B.O. ROOF DECK FIELD VERIFY THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LIGHT PER SCHED. P2 TYP. MIRROR SET FLUSH WITH WALL TILE. TILE TO ALUM. FRAME JOINT SHALL BE CAULKED (NOT GROUTED) W/ CAULK TO MATCH GROUT. ALUM./GLASS DOOR FRAME. A6.1 2 FULL TILE T1 LINE OF TOP OF WALL BEYOND ABOVE DOOR IN VESTIBULE. T1 A2.0 3 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LIGHT PER SCHED. P2 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK A2.0 3 P2 TYP. EXISTING GYP. BD. SURFACE UP TO DECK. PATCH & REPAIR AS REQ'D. TO RECEIVE NEW FINISHES SCHED. P2 P1 / P 6 VE R I F Y A6.3 4 WALLS TO BE PTD. PER PLANS. SEE SHEET A2.4, TYP. B1 P2TYP.TYP. B1 P1 TYP. 9' - 6 " VE R I F Y VE R I F Y RECESSED LIGHT COVE SHOWN DASHED. WALL GRAPHIC BY SALON LOFTS T1 BEYOND ABOVE DOOR A6.1 2 ALUM./GLASS STOREFRONT ENTRY SYSTEM BEYOND WITH DOOR. START TILE W/ FULL HEIGHT TILE @ FLOOR, TYP. T1 TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. SEE ELEVATION 7/A4.2 FOR MORE INFORMATION MILLWORK DISPLAY WALL W/ LED/LCD DISPLAY, ALL INSTALLED BY G.C. P1 B1 TYP. P1 P7 B1 TYP. TYP.P1 P7 B1 TYP. TYP. P1 P7 B1 TYP. TYP. P2BEYOND P2 BEYOND P2 BEYOND P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T 9' - 6 " TY P . W A L L H E I G H T P2BEYOND P2BEYOND 9' - 6 " TY P . W A L L H E I G H T TYP.A6.3 4 RECESSED FIRE EXTINGUISHER CABINET- CENTERED ON WALL. C5 WOOD FRAMED GLASS MIRROR (VERT.)- CENTER ON WALL. 3' - 0 " BO T T O M OF F R A M E FULL TILE 3 FULL TILESEQ.EQ. 9' - 0 " CE I L I N G H T . I N V E S T I B U L E FU L L TI L E 4 F U L L T I L E S FU L L TI L E PA R T I A L TI L E FULL TILE 3 FULL TILES EQ.EQ. 9' - 0 " CE I L I N G H T . I N V E S T I B U L E FU L L TI L E 4 F U L L T I L E S FU L L TI L E PA R T I A L TI L E END WALL OF HALLWAY # 104 BEYOND END WALL OF HALLWAY #105 BEYOND END WALL OF HALLWAY #102 BEYOND END WALL OF HALLWAY #114 BEYOND END WALL OF HALLWAY #104 BEYOND P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4.P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. WOOD FRAMED GLASS MIRROR (HORIZ.) BEYOND- CENTERED ON WALL. C13 TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. 3' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " 1'-6"1'-6" 4 FULL TILES FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK 6' - 4 " VE R I F Y 2' - 8 " VE R I F Y FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK TYP. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK SPA LOFT WALL UP TO DECK. P1 B1 P7 TYP. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. TYP.A6.3 4 M25InterlockingRock BLOCK BEYOND. PAINT (FLAT). RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" MILLWORK DISPLAY WALL W/ LED/LCD DISPLAY, ALL INSTALLED BY G.C. 9' - 6 " TY P . W A L L H E I G H T FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK T1 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. TYP.A6.3 4 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK TYP.A6.3 4 TILE EDGE RETURNS (1) FULL TILE WIDTH. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK 9' - 6 " TY P . W A L L H E I G H T TYP.A6.3 4 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. T1 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. SPA LOFT WALL UP TO DECK. 6" HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL.TYP. A6.3 4 A6.4 3 A6.4 3 SIM. 9' - 6 " TY P . W A L L H E I G H T P1 B1 P7 TYP. DOOR TRACK OVERHANGS TILE. DO NOT ATTACH THROUGH TILE. P3 END OF InterlockingRock BLOCK WALL. (FLAT).P3 P3 SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N INTERIOR ELEVATIONS A4.0 1 A4.0 1/4"=1'-0" TYPICAL STOREFRONT ELEVATION 2 A4.0 1/4"=1'-0" TYPICAL LOFT WALL ELEVATION 3 A4.0 1/4"=1'-0" VESTIBULE '101' - SOUTH ELEV.4 A4.0 1/4"=1'-0" VESTIBULE '101' - NORTH ELEV.5 A4.0 NOT USED 6 A4.0 1/4"=1'-0" HALLWAY '102' - EAST ELEVATION 7 A4.0 1/4"=1'-0" HALLWAY '104' - NORTH ELEVATION 8 A4.0 1/4"=1'-0" HALLWAY '105' - EAST ELEVATION 9 A4.0 1/4"=1'-0" HALLWAY '102' - WEST ELEVATION 10 A4.0 1/4"=1'-0" HALLWAY '104' - SOUTH ELEVATION 11 A4.0 1/4"=1'-0" HALLWAY '105' - WEST ELEVATION RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T C5 WOOD FRAMED GLASS MIRROR (HORIZ.)- CENTER BETWEEN DOORS. 2' - 6 " RECESSED FIRE EXTINGUISHER CABINET- CENTERED ON WALL. 3' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " P1 P7 B1 TYP. TYP. P1 P7 B1 TYP. TYP. P1 P2 P1 P2 END WALL OF HALLWAY # 105 BEYOND END WALL OF HALLWAY #112 BEYOND END WALL OF HALLWAY #106 BEYOND END WALL OF HALLWAY #114 BEYOND P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. M3 UTILITY ROOM WALL UP TO DECK. A6.3 4 TYP. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK 3' - 6 " BO T T O M O F FR A M E ACCESSIBLE TOILET ROOM SIGNAGE (SEE A0.3). 6" EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. A6.3 4 TYP. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK A6.3 4 TYP.P2 P1 VACANT LEASE SPACE WALL UP TO DECK. LINE OF UTILITY ROOM WALL UP TO DECK. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. VACANT LEASE SPACE WALL UP TO DECK. P1 B1 P7 TYP. P1 B1 P7 TYP. A6.3 4 TYP. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. PAY STATION, SEE 7/A6.2. MILLWORK DISPLAY WALL BEYOND. P3 RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T C5 WOOD FRAMED GLASS MIRROR (HORIZ.)- CENTER BETWEEN DOORS. 2' - 6 " RECESSED FIRE EXTINGUISHER CABINET- CENTERED ON WALL. 3' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " P1 P7 B1 TYP. TYP. P1 P7 B1 TYP. TYP. P1 P2 P1 P2 END WALL OF HALLWAY # 105 BEYOND END WALL OF HALLWAY #112 BEYOND END WALL OF HALLWAY #106 BEYOND END WALL OF HALLWAY #114 BEYOND P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. M3 UTILITY ROOM WALL UP TO DECK. A6.3 4 TYP. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK 3' - 6 " BO T T O M O F FR A M E ACCESSIBLE TOILET ROOM SIGNAGE (SEE A0.3). 6" EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. A6.3 4 TYP. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK A6.3 4 TYP.P2 P1 VACANT LEASE SPACE WALL UP TO DECK. LINE OF UTILITY ROOM WALL UP TO DECK. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. VACANT LEASE SPACE WALL UP TO DECK. P1 B1 P7 TYP. P1 B1 P7 TYP. A6.3 4 TYP. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. PAY STATION, SEE 7/A6.2. MILLWORK DISPLAY WALL BEYOND. P3 SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N INTERIOR ELEVATIONS A4.1 1 A4.1 1/4"=1'-0" HALLWAY '106' - NORTH ELEVATION 2 A4.1 1/4"=1'-0" HALLWAY '106' - SOUTH ELEVATION 3 A4.1 1/4"=1'-0" HALLWAY '112' - EAST ELEVATION 4 A4.1 1/4"=1'-0" HALLWAY '112' - WEST ELEVATION A COMMUNITY OFINDIVIDUAL SALON OWNERS RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. 9' - 6 " TY P . W A L L H E I G H T P2BEYOND 9' - 6 " TY P . W A L L H E I G H T P2 BEYOND P2BEYOND 3' - 6 " BO T T O M OF F R A M E C5 WOOD FRAMED GLASS MIRROR (HORIZ.) CENTER BETWEEN DOORS. 3' - 6 " BO T T O M OF F R A M E C5 WOOD FRAMED GLASS MIRROR (HORIZ.)- CENTER ON WALL. END WALL OF HALLWAY #113 BEYOND END WALL OF HALLWAY #114 BEYOND END WALL OF HALLWAY #114 BEYOND END WALL OF HALLWAY #112 BEYOND END WALL OF HALLWAY #102 BEYOND P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. SEE ELEVATION 7/A4.2 FOR MORE INFORMATION MILLWORK DISPLAY WALL W/ LED/LCD DISPLAY, ALL INSTALLED BY G.C. PAY STATION CABINET, SEE 7/A6.2. P1 TYP. TYP. P1 P7 B1 TYP. TYP. P1 P7 B1 TYP. TYP. 2' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " B1 P7EQ.EQ. 14'-5"L (VFY.) 5' - 6 " 7' - 3 1 / 2 " HIDE LED FLEX POWER SUPPLY BEYOND EDGE OF GRAPHIC PANEL, TYP. LIGHT AS SCHED. LIGHT AS SCHED. THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4.P2 13'-4" 5 FULL PANELS P3 M24InterlockingRock PANELS OVER GYP. BD. WALL SURFACE. INSTALL PER MFR'S. INSTRUCTIONS. ALL JOINTS TO BE GLUED WITH SEAMS & EDGES FILLED W/ FORTIFIED SPACKLING COMPOUND & SANDED SMOOTH, PAINT (FLAT). 3' - 0 " P7 6' - 6 " CUT PANEL B1 CUT DOWN AS REQ'D. 3" 8' - 0 " InterlockingRock BLOCK INSTALL PER MANUF. INSTRUCTIONS USING STANDARD 1 5/8"x 1 1/4" MTL. STUDS AND TRACK. ALL JOINTS GLUED, SEAMS AND EDGES FILLED WITH FORTIFIED SPACKLING COMPOUND & SANDED SMOOTH. PAINT (FLAT).P3 6'-0" NOTE: CONTRACTOR SHALL COORD. STEEL REQ'D. TO STIFFEN END OF WALL WITH SALON LOFTS REP. ON SITE. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LIGHT AS SCHED.LIGHT AS SCHED. THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4.P2 M25 A6.3 4 TYP. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P1 B1 P7 TYP. P3 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK A6.3 4 TYP. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. P3 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS.EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. TYP.A6.3 4 ILLUMINATED SALON LOFTS PUCK & GRAPHIC PANEL, SUPPLIED BY SALON LOFTS / INSTALLED BY G.C. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P3 TYP.A6.3 4 A6.4 3 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P3 EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. P3 PAY STATION- SEE 7/A6.2. A COMMUNITY OFINDIVIDUAL SALON OWNERS RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. TYP. LOFT SIGNAGE BEYOND, SEE 7/A6.1. RECESSED EMER. LIGHT FIXTURE IN WALL. PAINT COVER TO MATCH WALL. 6" 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. P2 BEYOND 9' - 6 " TY P . W A L L H E I G H T LOFT DOOR IN 'OPEN' POSITION SHOWN DASHED. 9' - 6 " TY P . W A L L H E I G H T P2BEYOND 9' - 6 " TY P . W A L L H E I G H T P2 BEYOND P2BEYOND 3' - 6 " BO T T O M OF F R A M E C5 WOOD FRAMED GLASS MIRROR (HORIZ.) CENTER BETWEEN DOORS. 3' - 6 " BO T T O M OF F R A M E C5 WOOD FRAMED GLASS MIRROR (HORIZ.)- CENTER ON WALL. END WALL OF HALLWAY #113 BEYOND END WALL OF HALLWAY #114 BEYOND END WALL OF HALLWAY #114 BEYOND END WALL OF HALLWAY #112 BEYOND END WALL OF HALLWAY #102 BEYOND P2 THREADED ROD & UNI-STRUT SUPPORTS FOR WALL/HEADER CONDITION TO BE PAINTED , SEE DETAIL 5/A6.1. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. SEE ELEVATION 7/A4.2 FOR MORE INFORMATION MILLWORK DISPLAY WALL W/ LED/LCD DISPLAY, ALL INSTALLED BY G.C. PAY STATION CABINET, SEE 7/A6.2. P1 TYP. TYP. P1 P7 B1 TYP. TYP. P1 P7 B1 TYP. TYP. 2' - 6 " 2' - 6 " 2' - 6 " 2' - 6 " B1 P7EQ.EQ. 14'-5"L (VFY.) 5' - 6 " 7' - 3 1 / 2 " HIDE LED FLEX POWER SUPPLY BEYOND EDGE OF GRAPHIC PANEL, TYP. LIGHT AS SCHED. LIGHT AS SCHED. THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4.P2 13'-4" 5 FULL PANELS P3 M24InterlockingRock PANELS OVER GYP. BD. WALL SURFACE. INSTALL PER MFR'S. INSTRUCTIONS. ALL JOINTS TO BE GLUED WITH SEAMS & EDGES FILLED W/ FORTIFIED SPACKLING COMPOUND & SANDED SMOOTH, PAINT (FLAT). 3' - 0 " P7 6' - 6 " CUT PANEL B1 CUT DOWN AS REQ'D. 3" 8' - 0 " InterlockingRock BLOCK INSTALL PER MANUF. INSTRUCTIONS USING STANDARD 1 5/8"x 1 1/4" MTL. STUDS AND TRACK. ALL JOINTS GLUED, SEAMS AND EDGES FILLED WITH FORTIFIED SPACKLING COMPOUND & SANDED SMOOTH. PAINT (FLAT).P3 6'-0" NOTE: CONTRACTOR SHALL COORD. STEEL REQ'D. TO STIFFEN END OF WALL WITH SALON LOFTS REP. ON SITE. P2 THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4. LIGHT AS SCHED.LIGHT AS SCHED. THREADED ROD & UNI-STRUT SUPPORTS FOR FLOATING GYP. BD. CEILING TO BE PAINTED , SEE DETAIL 5/A6.4.P2 M25 A6.3 4 TYP. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P1 B1 P7 TYP. P3 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK A6.3 4 TYP. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. P3 HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS.EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. TYP.A6.3 4 ILLUMINATED SALON LOFTS PUCK & GRAPHIC PANEL, SUPPLIED BY SALON LOFTS / INSTALLED BY G.C. FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P3 TYP.A6.3 4 A6.4 3 FINISH FLOOR +0'-0" A.F.F. FIELD VERIFY B.O. ROOF DECK P3 EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. HVAC DUCTWORK HUNG FROM B.O. STRUCT. SEE MECH. PLANS FOR FINISH & HANGING METHODS. EXPOSED DUCTS & DIFFUSERS. DO NOT PAINT. SEE MECH. PLANS. P3 PAY STATION- SEE 7/A6.2. A6.1 4 A6.1 3 A6.1 4SEE DETAIL 3/A4.0 FOR FINISH SELECTIONS T1 (1) 4'-0" L. LED LINEAR WALL WASH FIXTURE SUPPLIED BY SALON LOFTS & INSTALLED BY G.C. IN RECESSED LIGHT COVE. COORD. LIGHTING TYPE & DETAILS W/ ELEC. & 3/A6.1. TYP. EA. SIDE ACRYLIC PANEL (BY G.C.) W/ SALON LOFTS GRAPHIC PROVIDE KEYED CABINET LOCK. NAIL POLISH CABINET W/ 1/8" CLEAR TEMP. GLASS DOOR PANELS IN P.LAM. FRAME . EXHAUST GRILLE IN WALL- PAINT TO MATCH WALL & SEE MECH. PLANS. DISPLAY CABINET OUTER FRAME TO BE 5" DEEP. PROVIDE (9) 4" DEEP FIXED SHELVES SPACED 4" CLEAR TYPICAL AS DIMENSIONED. PL-2 B1 P1 1'-6"4'-3" 4" TY P . EQ.EQ. 2' - 0 " 9 1 / 2 " 4' - 2 1 / 2 " 7' - 0 " 9' - 6 " TY P . W A L L H E I G H T A6.2 5 PL-2 PL-2 PL-2 PL-2 P.LAM PORTABLE CABINET ON CASTERS , SEE DETAIL 6/A6.2. PROVIDE KEYED CABINET LOCK TYP. EACH DOOR. LOWER CABINET DOORS W/ FINISH. PROVIDE (3) ADJUSTABLE SHELVES EACH SECTION. (PROVIDE DOOR STOPS @ UPPER CORNER NEAR FINGER PULL OPENING). UPPER CABINET DOORS W/ PERIMETER FRAME W/ 1/8" FROSTED ACRYLIC PANEL. PROVIDE (1) ADJUSTABLE SHELF EACH SECTION. WALL MOUNTED P.LAM CABINETS W/ TYP. ALL EXPOSED SURFACES. NAIL SINK- SEE 6/A2.2. B1 P1 1'-6" 1' - 6 3 / 4 " 3/ 4 " 3' - 4 " 1' - 8 " 7' - 0 " 1'-6"1'-6"1'-0" 4'-6" 5" 5"5" 4'-8" COORD. W/ FLOOR PLAN 3'-10"5"5" 4'-8" COORD. W/ FLOOR PLAN 3'-10" 2' - 8 " 4' - 7 " 5" 1' - 1 1 " 6"2" 4" FINISH ALL EXPOSED SURFACES OF PAY STATION CASEWORK , U.N.O. P.LAM DRAWER FRONT . P.LAM DOOR FRONT . PL-4 PL-4 PL-4 P.LAM WORK SURFACE TOP AS DETAILED .PL-1 PL-4 PULL-OUT CHECK WRITING LEDGE .PL-1 8' - 0 " LED/LCD DISPLAY- MOUNT TOP OF DISPLAY AS INDICATED. PL-4 B1 4' - 8 " 4" 1' - 6 " 1' - 1 " 8' - 0 " 5" 6' - 0 " 1' - 6 " B1 INTERIOR ELEVATIONS A4.2 2 A4.2 1/4"=1'-0" HALLWAY '114' - NORTH ELEVATION1 A4.2 1/4"=1'-0" HALLWAY '113' - EAST ELEVATION 4 A4.2 1/4"=1'-0" HALLWAY '114' - SOUTH ELEVATION3 A4.2 1/4"=1'-0" HALLWAY '113' - WEST ELEVATION 5 A4.2 1/2"=1'-0" NAIL ' 02' - WEST ELEVATION SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N 6 A4.2 1/2"=1'-0" NAIL ' 02' - EAST ELEVATION 7 A4.2 1/2"=1'-0" ENLARGED WAY FINDING ELEV.8 A4.2 1/2"=1'-0" ENLARGED WAY FINDING ELEV.9 A4.2 1/2"=1'-0" ENLARGED GRAPHIC WALL DISPLAY A6.0 3 LOFT DOOR AS SCHED. IN "OPEN" POSITION. WALL FINISH TRANSITION AS SCHEDULED. 6"6" FINISHES RETURN/ WRAP JAMB, TYP. NOTE: SEE PLAN FOR TRUE CONFIGURATION. 10'-0" LONG HARDWOOD SILL GUIDE TRACK, SCREWED INTO CONC. SLAB, TYP. BEARING ASSEMBLY & HEAVY DUTY BRACKET. HEAVY DUTY TRACK, SEE DETAIL 1A/A6.4 LOFT DOOR AS SCHED. IN "CLOSED" POSITION. DOOR HANDLE. 1/2" CLEAR TEMPERED GLAZING. DOOR LOCKING CYLINDER AS SCHED. WALL BASE AS SCHED. LINE OF FINISHED FLOOR. RECESSED BOTTOM GUIDE AS SCHED. COORD. DEPTH OF RECESS W/ DOOR HARDWARE. DIMENSION INDICATES DOOR OVERLAP OF FINISHED GYP. OPENING. A6.0 6 A6.0 9 WALL BASE AS SCHED. GLAZING BASE. FIN. DOOR HEAD EL. = 7'-10" TOP OF FLOOR EL. = 0'-0" 6'-4" FINISHED OPENING 2"3'-7"2'-6"3"3'-6" DOOR IN "OPEN" POSITION 10'-0" (TRACK LENGTH) WALL FINISH AS SCHED. LOFT SIGNAGE, SEE DETAIL 7/A6.1. ADJACENT DOOR OPENING SHOWN DASHED. A6.0 3 LOFT DOOR AS SCHED. IN "OPEN" POSITION. WALL FINISH TRANSITION AS SCHEDULED. 6"6" FINISHES RETURN/ WRAP JAMB, TYP. NOTE: SEE PLAN FOR TRUE CONFIGURATION. 8'-6" LONG HARDWOOD SILL GUIDE TRACK, SCREWED INTO CONC. SLAB, TYP. BEARING ASSEMBLY & HEAVY DUTY BRACKET. HEAVY DUTY TRACK, SEE DETAIL 1B/A6.4 ADJACENT DOOR OPENING SHOWN DASHED. WALL FINISH AS SCHED. LOFT SIGNAGE, SEE DETAIL 7/A6.1. LOFT DOOR AS SCHED. IN "CLOSED" POSITION. DOOR HANDLE. 1/2" CLEAR TEMPERED GLAZING. DOOR LOCKING CYLINDER AS SCHED. WALL BASE AS SCHED. LINE OF FINISHED FLOOR. RECESSED BOTTOM GUIDE AS SCHED. COORD. DEPTH OF RECESS W/ DOOR HARDWARE. DIMENSION INDICATES DOOR OVERLAP OF FINISHED GYP. OPENING. A6.0 6 A6.0 9 WALL BASE AS SCHED. GLAZING BASE. TOP OF FLOOR EL. = 0'-0" 6'-4" FINISHED OPENING 2"3'-7"2'-6"3"2'-0" DOOR IN "OPEN" POSITION 8'-6" (TRACK LENGTH) FIN. DOOR HEAD EL. = 7'-10" TOP OF WALL EL. = 9'-6" TOP OF WALL EL. = 9'-6" A6.0 3LOFT DOOR AS SCHED. IN "OPEN" POSITION. WALL FINISH TRANSITION AS SCHEDULED. FINISHES RETURN/ WRAP JAMB, TYP. NOTE: SEE PLAN FOR TRUE CONFIGURATION. 6'-3" LONG HARDWOOD SILL GUIDE TRACK, SCREWED INTO CONC. SLAB, TYPICAL. BEARING ASSEMBLY & HEAVY DUTY BRACKET. HEAVY DUTY TRACK, SEE DETAIL 1D/A6.4 WALL FINISH AS SCHED. LOFT DOOR AS SCHED. IN "CLOSED" POSITION. DOOR HANDLE. 1/2" CLEAR TEMPERED GLAZING. DOOR LOCKING CYLINDER AS SCHED. WALL BASE AS SCHED. LINE OF FINISHED FLOOR. RECESSED BOTTOM GUIDE AS SCHED. COORD. DEPTH OF RECESS W/ DOOR HARDWARE.DIMENSION INDICATES DOOR OVERLAP OF FINISHED GYP. OPENING. A6.0 6 A6.0 9 GLAZING BASE. TOP OF FLOOR EL. = 0'-0" 5'-0"3'-2" DOOR IN OPEN POSITION 2'-10"3" 6'-0" (TRACK LENGTH) FIN. DOOR HEAD EL. = 7'-10" TOP OF WALL EL. = 9'-6" 6"6" 2" LOFT SIGNAGE , SEE 7/A6.1. (APPLY W/ CLEAR DLB. SIDED TAPE TO F.O. GLASS.). 7" TYP. U.N.O. 4 7/8"7" TYP. U.N.O. 6'-4" 3'-7"2'-6"3" 3'-6"3" 2" "HALLWAY" SIDE "LOFT" SIDE EQ . 2" EQ . FL O O R F I N I S H AS S C H E D . FL O O R F I N I S H AS S C H E D . WALL PARTITION AS SCHEDULED. DOOR BOTTOM GUIDE- SET IN 6" FROM DOOR END. A6.0 1 4" 7/ 8 " NOTE: SEE PLAN FOR TRUE CONFIGURATION. ADJACENT DOOR OPENING & DOOR AS SCHED. SEE FLOOR PLAN. LOFT SIGNAGE LOCATION SHOWN DASHED ABOVE. SEE DETAIL 7/A6.1. METAL STUD FRAMING AS REQ'D. FOR HEADER SUPPORT. TYP. BOTH SIDES. WALL PARTITION AS SCHEDULED. 3'-6" DOOR IN "OPEN" POSITION DOOR SHOWN IN "OPEN" POSITION (DASHED). GLAZING BASE. 1/2" CLEAR TEMP. GLAZING. LINE OF FLOOR FINISH TRANSITION AS DIMENSIONED OFF FINISHED FACE OF WALL PARTITION AS SHOWN. F1 F2 7" TYP. U.N.O. 4 7/8"7" TYP. U.N.O. 6'-4" 3'-7"2'-6"3" 3'-6"3" 2" "HALLWAY" SIDE "LOFT" SIDE EQ . 2" EQ . FL O O R F I N I S H AS S C H E D . FL O O R F I N I S H AS S C H E D . WALL PARTITION AS SCHEDULED. DOOR BOTTOM GUIDE- SET IN 6" FROM DOOR END. A6.0 4 4" 7/ 8 " NOTE: SEE PLAN FOR TRUE CONFIGURATION. ADJACENT DOOR OPENING & DOOR AS SCHED. SEE FLOOR PLAN. LOFT SIGNAGE LOCATION SHOWN DASHED ABOVE. SEE DETAIL 7/A6.1. METAL STUD FRAMING AS REQ'D. FOR HEADER SUPPORT. TYP. BOTH SIDES. WALL PARTITION AS SCHEDULED. 2'-0" DOOR IN "OPEN" POSITION DOOR SHOWN IN "OPEN" POSITION (DASHED). GLAZING BASE. 1/2" CLEAR TEMP. GLAZING. LINE OF FLOOR FINISH TRANSITION AS DIMENSIONED OFF FINISHED FACE OF WALL PARTITION AS SHOWN. F1 F2 2'-10"2" "HALLWAY" SIDE "LOFT" SIDE FL O O R F I N I S H AS S C H E D . FL O O R F I N I S H AS S C H E D . DOOR BOTTOM GUIDE- SET IN 6" FROM DOOR EDGE. A6.0 7 DOOR SHOWN IN "OPEN" POSITION (DASHED). GLAZING BASE. 1/2" CLEAR TEMP. GLAZING. LINE OF FLOOR FINISH TRANSITION AS DIMENSIONED OFF FINISHED FACE OF WALL PARTITION AS SHOWN. 3" 3'-1" 7/ 8 " 1'-11" METAL STUD FRAMING AS REQ'D. FOR HEADER SUPPORT. TYP. BOTH SIDES. WALL PARTITION AS SCHEDULED. 3'-0" DOOR IN "OPEN" POSITION F2 F1 4" EQ . 2" EQ . 5'-0" 3' - 6 " 3" 1/2" CLEAR TEMPERED GLAZING W/ POLISHED EDGES, TYP. EQ.EQ. STYLMARK GLAZING BASE #110482 2"x4" (FINISH #218-BRUSHED BRITE STAINLESS STEEL). NOTE: PROVIDE STYLMARK 1/8" ENDCAP #410367 TYP. @ EXPOSED ENDS WITH MATCHING FINISH. WALL BASE BEYOND AS SCHED. STYLMARK ANCHOR #110358 W/ TOGGLE TO FINISHED FLOOR. ANCHOR INTO CONC. SLAB. 4" CHANNEL LINE OF WALL PARTITION JAMB BEYOND. FLOOR FINISH AS SCHED.F1 WALL BASE BEYOND AS SCHED. SET GLAZING W/ BLACK GLAZING VINYL #226024 & #226025, AND SETTING BLOCKS #226014. BOTTOM GUIDE AS SCHEDULED RECESSED INTO DOOR BOTTOM. VERIFY RECESSED DEPTH W/ DOOR HARDWARE. 7/8" 1/ 2 " 5/ 8 " HARDWOOD SILL GUIDE TRACK SCREWED INTO FLOOR SLAB THROUGH RECESSED SLOT. LOFT DOOR AS SCHED. IN "OPEN" POSITION. CARPET FLOOR FINISH AS SCHED.F2 TOP OF WALL EL. = 9'-6" ABOVE FINISHED FLOOR SURFACE FINISHED DOOR HEAD EL. = 7'-10" ABOVE FINISHED FLOOR SURFACE EQ.EQ.CHANNEL WALL PARTITION AS SCHED. STYLMARK GLAZING HEAD #110360 1"x2". (FINISH #218- BRUSHED BRITE STAINLESS STEEL) NOTE: PROVIDE STYLMARK 1/8" ENDCAP #410412 TYP. @ EXPOSED ENDS WITH MATCHING FINISH. 1/2" CLEAR TEMPERED GLAZING. FINISHED FLOOR SURFACE WALL PARTITION AS SCHED. METAL STUD BOX BEAM - 3 5/8" (18 GA.) STUDS, 1 5/8" FLANGE, W/ 3 5/8" (20 GA.) RUNNER TOP & BOTTOM. LINE OF WALL PARTITION JAMB BEYOND. HEAVY DUTY DOOR TRACK. RETURN GYP. BD. TO GLAZING HEAD AS SHOWN. SET GLAZING W/ BLACK GLAZING VINYL #226013. TOP OF WALL EL. = 9'-6" ABOVE LINE OF WALL PARTITION JAMB BEYOND. FINISHED GYP. BD. HEAD AS SHOWN. A6.3 4 TYP. (2) 2x4 F.R.T. WOOD BLOCKING. (2) 2x4 F.R.T. WOOD BLOCKING. A6.3 4 TYP. BEARING ASSEMBLY AS SUPPLIED BY MFR. HEAVY DUTY TRACK W/ 2-5/8" SPACERS & MOUNTING SCREWS INTO SOLID WD. BLOCKING BY G.C. HEAVY DUTY BRACKET W/ MOUNTING BOLTS AS SUPPLIED BY MFR. 1 3/4" THICK DOOR PANEL AS SCHED.1 3/4" DOOR FINISHED DOOR HEAD EL. = 7'-10" A.F.F. 2 1 / 4 " T. O . D O O R TO OF T R A C K 3 1 / 8 " METAL STUD BOX BEAM - 3 5/8" (18 GA.) STUDS, 1 5/8" FLANGE, W/ 3 5/8" (20 GA.) RUNNER TOP & BOTTOM. CERAMIC TILE FLOOR FINISH AS SCHED.F1 SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N DOOR & SIDELIGHT ELEVATIONS & DETAILS A6.0 1 A6.0 1/2"=1'-0" 10'-0" LONG DOOR TRACK TYPICAL LOFT DOOR ELEVATION 4 A6.0 1/2"=1'-0" 8'-6" LONG DOOR TRACK TYPICAL LOFT DOOR ELEVATION 2 A6.0 3/4"=1'-0" 10'-0" LONG DOOR TRACK TYPICAL LOFT DOOR JAMB DETAIL 5 A6.0 3/4"=1'-0" 8'-6" LONG DOOR TRACK TYPICAL LOFT DOOR JAMB DETAIL 3 A6.0 3"=1'-0" LOFT OPENING GLAZING DETAIL 6 A6.0 3"=1'-0" LOFT OPENING DOOR HEAD DETAIL 9 A6.0 3"=1'-0" LOFT OPENING GLAZING DETAIL7 A6.0 1/2"=1'-0" 6'-0" LONG DOOR TRACK TYPICAL LOFT DOOR ELEVATION 8 A6.0 3/4"=1'-0" 6'-0" LONG DOOR TRACK TYPICAL LOFT DOOR JAMB DETAIL LOFT DOOR AS SCHED. IN "OPEN" POSITION. WALL BASE AS SCHED. WALL FINISH TRANSITION. DIM. INDICATES DOOR OVERLAP OF FINISHED GYP. BD. OPENING. WALL FINISH AS SCHED. RECESSED BOTTOM GUIDE AS SCHED. COORD. DEPTH OF RECESS W/ DOOR HARDWARE. 7'-1" LONG HARDWOOD SILL GUIDE TRACK, SCREWED INTO FLOOR, TYP. LOFT SIGNAGE , SEE 7/A6.1. (APPLY W/ CLEAR DLB. SIDED TAPE TO F.O. GLASS.). LOFT DOOR AS SCHED. IN "CLOSED" POSITION. DOOR HANDLE. 1/2" CLEAR TEMPERED GLAZING. DOOR LOCKING CYLINDER AS SCHEDULED. LINE OF FINISHED FLOOR. GLAZING BASE. EL. = 7'-10" FINISHED DOOR HEAD EL. = 0'-0" TOP OF FLOOR 7' - 1 0 " (F U T U R E G Y P . B D . O P E N I N G ) 6'-0" (FUTURE GYP. BD. OPENING) 9' - 6 " LINE OF FUTURE GYP. BD. OPENING SHOWN W/ HEAVY DASH. GYP. BD. PANEL JOINTS TO BE LOCATED @ EDGE OF FUTURE GYP. BD. OPENING FOR EASE OF OPENING REMOVAL & CONSTR. G.C. TO PROVIDE F.R.T. BLKG. WITHIN FRAMED WALL CONSTRUCTION AS REQ'D. FOR FUTURE MILLWORK ITEMS. COORD. MILLWORK SPECIFICATIONS & LOCATIONS W/ OWNER PRIOR TO CONSTR. 1' - 8 " (W A L L T O RE M A I N ) EQUAL (WALL TO REMAIN) EQUAL (WALL TO REMAIN) PERMANENT FRAMING AS REQ'D. SHOWN DASHED. TEMPORARY FRAMING AS REQ'D. WITHIN FUTURE GYP. BD. OPENING AREA. AREA TO BE FRAMED SUCH THAT TEMPORARY FRAMING TO BE REMOVED WITHOUT DISRUPTING PERMANENT FRAMING SURROUNDING GYP. BD. OPENING. ELEC. AS NOTED, SEE ELEC. DRAWINGS. ALL ELEC., DATA, TELEPHONE, & LOW VOLTAGE ITEMS TO BE LOCATED WITHIN AREA OF PERMANENT FRMG. NO WIRES OR ITEMS TO BE LOCATED WITHIN AREA OF TEMP. FRAMING AT FUTURE GYP. BD. OPENING. WALL BASE AS SCHEDULED, SEE INTERIOR ELEVATIONS. BEARING ASSEMBLY & HEAVY DUTY BRACKET. HEAVY DUTY TRACK, SEE DETAIL 1C/A6.4. 6'-10" (TRACK LENGTH) 6"6" 3"3'-4"2" 3'-7" FINISHED OPENING 3'-6" DOOR IN "OPEN" POSITION B1 A6.0 3 A6.0 9 A6.0 6AT SIM. DOOR, NO GLASS CORNER. SEE SHEET A2.0 FOR OPENING DIMENSIONS. 3'-4" 2""HALLWAY" SIDE "LOFT" SIDE EQ . 2" EQ . FL O O R F I N I S H AS S C H E D . FL O O R F I N I S H AS S C H E D . DOOR BOTTOM GUIDE- SET IN 6" FROM DOOR EDGE. A6.1 9 DOOR SHOWN IN "OPEN" POSITION (DASHED). GLAZING BASE. 1/2" CLEAR TEMP. GLAZING. LINE OF FLOOR FINISH TRANSITION AS DIMENSIONED OFF FINISHED FACE OF WALL PARTITION AS SHOWN. 3" 3'-7" 7/ 8 " 2'-3" METAL STUD FRAMING AS REQ'D. FOR HEADER SUPPORT. TYP. BOTH SIDES. WALL PARTITION AS SCHEDULED. 3'-6" DOOR IN "OPEN" POSITION F2 F1 4" AT SIM. DOOR, NO GLASS CORNER. SEE SHEET A2.0 FOR OPENING DIMENSIONS. 5'-7" THREADED ROD & UNI-STRUT SUPPORTS FOR WALL / CEILING / FLOATING CEILING SUPPORT TO BE PAINTED . DESIGN BY OTHERS. G.C. TO PROVIDE UNI-STRUT SUPPORT AS REQUIRED WITHIN WALL CONSTRUCTION (SHOWN DASHED). FASTEN UNI-STRUT TO WALL FRAMING. EXISTING TRUSSES TO REMAIN. UNI-STRUT SUPPORT TO BE HUNG FROM LOWER CHORD, COORDINATE W/ LANDLORD. DECK ABOVE. TOP OF WALL CONSTRUCTION, SEE FLOOR PLAN FOR NOTES. P2 WALL SYSTEM AS SCHEDULED. 3'-0" / 3'-6" VERIFY WITH SHEET A2.0LINE OF FLOOR FINISH BELOW, SEE FINISH PLAN FOR DETAILS. GLAZING BASE AS NOTED, SEE DETAIL 9/A6.0. PROVIDE 1/2" CLEAR TEMPERED GLAZING W/ POLISHED EDGES, TYP. BUTT LAP CORNER AS INDICATED - NO SILICONE. LINE OF SOFFIT CONSTRUCTION ABOVE SHOWN DASHED - SEE 5/A6.1 FOR SUPPORT DETAILS. EQ EQ 3" "HALLWAY" SIDE "SPA LOFT" / "SPA VESTIBULE" SIDE DOOR OPENING AS SCHEDULED 7" DOOR W/ HOLLOW METAL FRAME & SOUND GASKETING AS SCHED. 'P5' PARTITION CONSTR. ('P6' SIM.) (CONFORM TO TEST #RAL-TL-07-168 / STC 60): FACE LAYER OF 5/8" GYP. BD. ON BASE LAYER OF 5/8" SOUNDBREAK XP GYP. BD. (SHOWN SHADED) VERT. APPLIED TO "HALLWAY"/ "TYPICAL LOFT" SIDE OF 6" MTL. STUDS AT 24" O.C. (16" O.C. @ 'P6' PARTITION TYPE) W/ 5 1/2" FIBERGLASS SOUND BATT INSUL. (2) LAYERS 5/8" GYP. BD. VERT. APPLIED TO "SPA LOFT" SIDE. BASE LAYER TO BE ATTACHED W/ 1" TYPE S SCREWS 24" O.C. FACE LAYER ATTACHED W/ 1 5/8" TYPE S SCREWS 12" O.C. VERTICAL JOINTS TO BE STAGGERED 24" EA. LAYER AND OPPOSITE SIDES. WALL TRACK TO BE SET IN ACOUSTICAL SEALANT & IS TO EXTEND FROM FINISHED FLOOR TO UNDERSIDE OF ROOF DECK. ALL SEAMS & GAPS IN WALL CONSTRUCTION TO BE FILLED W/ ACOUSTICAL SEALANT, TYPICAL AT EACH SIDE OF WALL. 4" LOFT SIGNAGE LOCATION (VERIFY W/ SHEET A2.3) AS DIMENSIONED. SEE DETAIL 7/A6.1. LINE OF FLOOR FINISH TRANSITION AS DIMENSIONED OFF FINISHED FACE OF WALL PARTITION AS SHOWN. NOTE: SEE PLAN FOR TRUE CONFIGURATION. P1 P5 SIGN FL O O R F I N I S H AS S C H E D . F2 FL O O R F I N I S H AS S C H E D . F6 P5 "T Y P I C A L L O F T " S I D E 8 1 / 2 " ALIGN NOTE: PENETRATIONS THROUGH THE P5/P6 PARTITION TYPE TO BE LIMITED. ALL PENETRATIONS ARE TO BE SEALED WITH ACOUSTICAL SEALANT, TYP. 3'-10" A.F.F. B.O. CARD HOLDER 3'-6" A.F.F. B.O. CARD HOLDER TYP. LOFT SIGNAGE W/ LOFT NUMBER & INTEGRAL CARD HOLDER. SUPPLIED & INSTALLED BY SALON LOFTS. TYP. CARD HOLDERS SUPPLIED & INSTALLED BY SALON LOFTS. OF LOFT SIGNAGE 5 1/2" NOTE: WHEN SIGNS ARE INDICATED TO BE ON THE GLASS WALLS, APPLY TO FACE OF GLASS W/ CLEAR DOUBLE SIDED TAPE. INSTALL W/ TYPICAL 5 1/2" DIMENSION FROM EDGE OF GLASS. LINE OF FINISHED DOOR OPENING. FINISHED DOOR PANEL AS SCHEDULED. 4'-2" A.F.F. B.O. CARD HOLDER @ SIGN WALL TILE. 1'-6" F.O. FRAME TO FACE OF GYP. BD. (1) FULL TILE (CUT AS REQ'D.) WALL SYSTEM AS SCHEDULED. WALL TILE SATIN ALUMINUM (AE) TILE CORNER TRIM - SCHLUTER-RONDEC. SEALANT TO MATCH GROUT. SATIN ALUMINUM (AE) TILE EDGE TRIM - SCHLUTER-SCHIENE. (1 ) F U L L T I L E WALL TILE WALL SYSTEM AS SCHEDULED SATIN ALUMINUM (AE) TILE EDGE TRIM - SCHLUTER-QUADEC 14" CLEAR MIRROR SET FLUSH WITH TILE MI R R O R T1 T1 T1 T1 A2.0 3 @ HEAD WALL GRAPHIC BY SALON LOFTS. RETURNS @JAMB BEYOND 1 1/2" SATIN ALUMINUM (AE) TILE TRIM - SCHLUTER RONDEC-STEP. LED LINEAR WALL WASH FIXTURE WITH ADJUSTABLE CLIP SUPPLIED BY SALON LOFTS & INSTALLED BY G.C. COORD. EXACT MOUNTING LOCATION WITH SALON LOFTS' REPRESENTATIVE. WALL TILE. 5/8" GYP. BD. OVER 3-5/8" METAL STUDS (ALL TO MATCH ADJACENT WALL HEIGHT). WALL SYSTEM AS SCHEDULED. 5" EXTEND TILE JAMB INTO & UP TO TOP OF LIGHT COVE. 4 5/8"+/- WALL TILE. 5/8" GYP. BD. OVER 3-5/8" METAL STUDS. WALL SYSTEM AS SCHEDULED. WALL TILE SILL. MATCH GROUT LINES WITH WALL TILE BELOW. 1' - 6 " FU L L T I L E TO F I N I S H E D FL O O R 4 5/8"+/- WALL GRAPHIC BY SALON LOFTS. ADHERED ACRYLIC PANEL OVER GYP. BD. TO BE ONE CONTIN. PIECE, TYP. (ALL BY G.C.)9 1/2"± T1 T1 T1 T1 ACRYLIC PANEL OVER GYP. BD. SURFACE TO BE ONE CONTIN. PIECE, TYP. INSTALL PRIOR TO LED LIGHT FIXTURE. (ALL BY G.C.) ACRYLIC PANEL EXTENDS TO TOP OF LIGHT COVE. SATIN ALUMINUM (AE) TILE CORNER TRIM - SCHLUTER RONDEC. A6.1 4 SATIN ALUMINUM (AE) TILE CORNER TRIM BEYOND - SCHLUTER RONDEC. MATCH GROUT LINES WITH ADJACENT WALL TILE. T1 PROVIDE HEMMED EDGE TO BREAK METAL CAP AT EDGE RETURN AS SHOWN. (TYP. BOTH SIDES.). 1 1 / 2 " RE T U R N PARTITION WALL AS SCHED. PROVIDE SEALANT, COLOR TO MATCH BREAK METAL. (TYP. BOTH SIDES.). PROVIDE PREFINISHED ALUMINUM BREAK METAL CAP @ EXPOSED END OF WALL PARTITION. COLOR TO MATCH GLAZING FRAME COLOR. ALUM. GLASS STOREFRONT GLAZING SYSTEM. NOTE: WHERE WALL PARTITION DOES NOT TERMINATE AT VERTICAL GLAZING MULLION, WALL PARTITION WITH BREAK METAL CAP TO RUN TO WITHIN 12"-34" OF GLASS FOR TERMINATION POINT. STUD= MULLION SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N CONSTRUCTION DETAILS A6.1 1 A6.1 3"=1'-0" TILE / MIRROR TRANSITION DETAIL 2 A6.1 3"=1'-0" TILE WALL CORNER DETAIL 3 A6.1 3"=1'-0" LIGHT COVE HEAD DETAIL 4 A6.1 3"=1'-0" LIGHT COVE SILL DETAIL (JAMB SIM.) 5 A6.1 1"=1'-0" LOFT SOFFIT DETAIL 7 A6.1 1 1/2"=1'-0" LOFT SIGNAGE DETAIL6 A6.1 6"=1'-0" WALL CAP AT GLAZING DETAIL 8 A6.1 1/2"=1'-0" LOFT WALL FRAMING ELEVATION 9 A6.1 1/2"=1'-0" 6'-10" LONG DOOR TRACK TYPICAL LOFT DOOR ELEVATION 10 A6.1 3/4"=1'-0" 6'-10" LONG DOOR TRACK TYPICAL LOFT DOOR JAMB DETAIL 11 A6.1 1 1/2"=1'-0" LOFT CORNER GLAZING DETAIL 12 A6.1 1 1/2"=1'-0" SPA LOFT WALL / JAMB DETAIL 3' - 0 " 2"1/ 4 " 5 3 / 4 " 1" 1' - 9 " 6" 8'-0" OVERALL CABINET WIDTH (FIELD VERIFY) EQ. SCRIBE PANEL 1'-6" TYP. 1'-6" TYP. 1'-6" TYP. 1'-6" TYP. EQ. SCRIBE PANEL 1'-6" TYP. EQ. SCRIBE PANEL 1'-6" TYP. 1'-6" TYP. 1'-6" TYP. 1'-6" TYP. EQ. SCRIBE PANEL 1'-6" TYP. 1' - 4 " 2' - 4 " A6.2 10 SINK AS SCHED. PROVIDE FALSE DRAWER PANEL @ SINK .6' - 8 " G.C. TO PROVIDE F.R.T. SOLID WOOD BLOCKING IN PARTITION AS DIRECTED BY CASEWORK SHOP DRAWINGS. WALL FINISH AS SCHED. P.LAM UPPER LEVEL CABINETS W/ TYP. ALL EXPOSED SURFACES. P.LAM SCRIBE PANEL TYP. BOTH SIDES. ADJUSTABLE SHELVES SHOWN DASHED WALL FINISH AS SCHED. P.LAM WORK SURFACE TOP AS DETAILED . BLACK 1/4" X 1/4" REVEAL. P.LAM DRAWERS . P.LAM DOOR PANEL . P.LAM SCRIBE PANEL TYP. BOTH SIDES. ADJUSTABLE SHELVES SHOWN DASHED. WALL FINISH AS SCHED. WALL BASE AS SCHED. A6.2 9 PL-2 PL-2 PL-1 PL-2 PL-2 PL-2 PL-2 NOTE: CASEWORK DIMENSIONS INDICATED FOR BASE CABINET (SHOWN DASHED BELOW) & COUNTERTOP. SEE ELEVATION FOR DIMENSIONS OF UPPER CABINETS & MIRROR. A6.2 3 CASEWORK CUBBY FOR STORAGE OF WORK TOP. RECESSED ADJUSTABLE SHELF LOCATION NOTE: FINISHED FRONT FACE OF COUNTERTOP TO ALIGN W/ FINISHED FRONT FACE OF CABINET BELOW AS DETAILED. LOFT STATIONS INSTALLED TIGHT TO ADJACENT GYP. BD. WALL PARTITION @ ONE SIDE & EXPOSED ON OPPOSITE SIDE. COORD. ORIENTATION OF EACH LOFT AS SHOWN ON FLOOR PLAN. G.C. TO PROVIDE F.R.T. SOLID WOOD BLOCKING IN PARTITION AS DIRECTED BY CASEWORK SHOP DRAWINGS. 1'-5 1/2"1'-6"2'-1"1'-6"1'-5 1/2" 8'-0" 1' - 1 " 2'-11 1/2" (TOP) 2'-1"2'-11 1/2" (TOP) PLAN VIEW 6" 1' - 8 " 6"2" FRONT ELEVATION VIEW NOTE: SEE PLAN FOR TRUE ORIENTATION. FINISH ALL EXPOSED SURFACES OF CASEWORK U.N.O. P.LAM DRAWER FRONT . P.LAM DOOR FRONT . PL-4 PL-4 PL-4 P.LAM WORK SURFACE TOP AS DETAILED .PL-1 3' - 0 " A6.2 8 1'-4" 3' - 0 " 4"GROMMET LOCATION @ REAR OF PAY STATION. CENTER ON COUNTER TOP WIDTH AS SHOWN. RADIUS WORK SURFACE TOP AS DIMENSIONED . SCRIBE TO WALL SURFACE. CABINET DOOR SWING SHOWN DASHED BELOW. PL-1 A6.2 8 3' - 0 " 6" 2" 1' - 4 " 3' - 0 " 3'-4"10"1'-6"10"1'-6" 3' - 1 " B. O . M I R R O R F R A M E 4' - 8 " WOOD FRAMED GLASS MIRROR, CENTER ABOVE SINK. P.LAM WORK SURFACE TOP AS DETAILED . P.LAM CASEWORK FIXTURE AS DETAILED . UPPER CABINET DOORS W/ PERIMETER FRAME W/ 1/8" FROSTED ACRYLIC PANEL. 1'-5 1/2"1'-6"2'-1"1'-6"1'-5 1/2" PROVIDE P.LAM FINISHED EDGE @ EXPOSED END OF WORK SURFACE TOP . SCRIBE P.LAM TOP TO WALL AS NECESSARY. PROVIDE P.LAM FINISH @ EXPOSED SIDE OF UPPER CABINET . NOTE: LOFT STATIONS INSTALLED TIGHT TO ADJACENT GYP. BD. WALL PARTITION @ ONE SIDE & EXPOSED ON OPPOSITE SIDE. COORDINATE ORIENTATION OF EACH LOFT AS SHOWN ON FLOOR PLAN. 1' - 6 " DE V I C E EQ.EQ. LINE OF ADJACENT WALL PARTITION. LINE OF ADJACENT WALL PARTITION. QUADRAPLEX OUTLET: REFER TO ELEC. DWGS FOR DETAILS. (TYP. BOTH SIDES). WHERE OUTLETS ARE BACK TO BACK, OUTLETS IN ONE LOFT TO BE 1'-6" & OPPOSING LOFT TO BE AT 1'-2".G.C. TO PROVIDE F.R.T. SOLID WOOD BLKG. IN PARTITION AS DIRECTED BY CASEWORK SHOP DRAWINGS. A6.2 11 A6.2 12 A6.2 4 4'-0" 4 1/2" WASTE & SUPPLY LINES: REFER TO PLUMBING DWGS FOR DETAILS. EQ.EQ. SURFACE MOUNTED LIGHT FIXTURE. SEE SHEET A3.0. 5"5"5"5" 5' - 1 0 " 10 1/2" EQ.EQ. PL-2 PL-2 PL-2 PL-1 PL-1 8"DE V I C E USB COMBINATION OUTLET: REFER TO ELEC. DWGS FOR DETAILS. WHERE OUTLETS ARE BACK TO BACK, STAGGER THEM SIDE BY SIDE. HAIR TRAP - MUST BE INSTALLED STRAIGHT AND TRUE, PERPENDICULAR TO CABINET FACE. SANITARY ROUGH-IN MUST BE PROPERLY LOCATED OR WILL BE SUBECT TO MODIFICATION AT CONTRACTOR'S EXPENSE. 1 1/2" 3 1 / 2 " 1'-5" 1 1/2" 2 3 / 4 " 1'-0" 2' - 4 " (2) 'WHITE' MELAMINE ADJUSTABLE SHELVES. 1'-6" 3' - 0 " 6" 1' - 9 " 1" 5 3 / 4 " 1/ 4 " 2" 2' - 6 " FINISHED FLOOR AS SCHED. P.LAM COUNTER TOP & EXPOSED SIDE FACES TO BE FINISHED . BLACK 1/4" X 1/4" REVEAL. P.LAM DRAWER W/ FULL EXTENSION HARDWARE . 1" FINGER PULL. FINISH ALL SURFACES WITHIN BLACK. P.LAM DOOR PANEL . 'WHITE' MELAMINE ADJUSTABLE SHELF. WALL BASE AS SCHED. 3' - 0 " 6" 1' - 9 " 1" 5 3 / 4 " 1/ 4 " 2" 2' - 6 " P.LAM FALSE DRAWER FRONT @ SINK . 1' - 4 " 2' - 4 " 1'-0" 2' - 4 " 2' - 4 " 1'-1" 3' - 0 " 6" 1' - 9 " 1" 5 3 / 4 " 1/ 4 " 2" 2' - 6 " 1'-0" 3' - 0 " 4'-4" A.F.F. (VERIFY) B.O. UPPER CABINET 1'-0" 1 1/2" 2 3 / 4 " FINISHED FLOOR AS SCHED. WOOD FRAMED GLASS MIRROR. P.LAM COUNTER TOP & EXPOSED SIDE FACES TO BE FINISHED . BLACK 1/4" X 1/4" REVEAL. P.LAM DRAWER W/ FULL EXTENSION HARDWARE . 1" FINGER PULL. FINISH ALL SURFACES WITHIN BLACK. P.LAM DOOR PANEL . 'WHITE' MELAMINE ADJUSTABLE SHELF. WALL BASE AS SCHED. UPPER CABINET DOORS W/ PERIMETER FRAME W/ 1/8" FROSTED ACRYLIC PANEL. 2" 2" 1"1" 1" G.C. TO PROVIDE F.R.T. SOLID WOOD BLOCKING IN PARTITION AS DIRECTED BY CASEWORK SHOP DRAWINGS. WALL PARTITION AS SCHEDULED. P.LAM UPPER CABINET W/ ALL EXPOSED SURFACES FINISHED . UNDER CABINET FINGER PULL . ALL EXPOSED SURFACE @ UNDERSIDE OF CABINET TO BE FINISHED . ALL EXPOSED SURFACE @ UNDERSIDE OF CABINET TO BE FINISHED . UNDER CABINET FINGER PULL . WALL PARTITION AS SCHEDULED. (2) 'WHITE' MELAMINE ADJUSTABLE SHELVES. G.C. TO PROVIDE F.R.T. SOLID WOOD BLOCKING IN PARTITION AS DIRECTED BY CASEWORK SHOP DRAWINGS. WALL PARTITION AS SCHEDULED. P.LAM UPPER CABINET W/ ALL EXPOSED SURFACES FINISHED . UNDER CABINET FINGER PULL . ALL EXPOSED SURFACE @ UNDERSIDE OF CABINET TO BE FINISHED . P.LAM COUNTER TOP & EXPOSED SIDE FACES TO BE FINISHED . BLACK 1/4" X 1/4" REVEAL. 1' - 4 " FINISHED FLOOR AS SCHED. 1" FINGER PULL. FINISH ALL SURFACES WITHIN BLACK. P.LAM DOOR PANEL . WALL BASE AS SCHED. 1'-6" (2) 'WHITE' MELAMINE ADJUSTABLE SHELVES. WALL PARTITION AS SCHEDULED. P.LAM UPPER CABINET W/ ALL EXPOSED SURFACES FINISHED . G.C. TO PROVIDE F.R.T. SOLID WOOD BLOCKING IN PARTITION AS DIRECTED BY CASEWORK SHOP DRAWINGS. PL-2 PL-2 PL-1 PL-2 PL-2 PL-1 PL-2 PL-2 PL-1 PL-2 PL-2 PL-2 PL-2 PL-2 PL-2 PL-2 PL-2 PL-2 PL-1 1'-6" (1'-0" @ SIDES) 1'-0" REAR & SIDE(2) ELEVATIONS SECTION 1'-0" 2'-0" A.F.F. (VERIFY) B.O. UPPER CABINET (1) 'WHITE' MELAMINE ADJUSTABLE SHELF. LOWER CABINET DOORS W/ FINISH. PROVIDE (3) ADJUSTABLE SHELVES EACH SECTION. ALL EXPOSED SURFACE @ UNDERSIDE OF CABINET TO BE FINISHED . 1" 1' - 8 " 2" 2" 1 1 / 2 " 3' - 4 " 5' - 0 " WALL MOUNTED P.LAM CABINETS W/ TYP. ALL EXPOSED SURFACES (3) 'WHITE' MELAMINE ADJUSTABLE SHELVES. 3"W. X 1 1/2"H. OPENING FOR FINGER PULL TO UPPER & LOWER DOORS. 1" WALL PARTITION AS SCHEDULED. UPPER CABINET DOORS W/ PERIMETER FRAME W/ 1/8" FROSTED ACRYLIC PANEL. PL-2 PL-2 PL-2 PL-2 1' - 8 1 / 4 " 1' - 8 1 / 4 " 2 1 / 4 " P.LAM COUNTER TOP & EXPOSED SIDE FACES TO BE FINISHED . P.LAM DOOR PANEL . COMMERCIAL GRADE 2 1/2" CASTERS.REAR PANEL P.LAM COUNTER TOP & EXPOSED SIDE FACES TO BE FINISHED . P.LAM SIDE(2) & REAR PANELS . COMMERCIAL GRADE 2 1/2" CASTERS. 2 1 / 4 " 1 1 / 2 " 3"W. X 1 1/2"H. OPENING FINGER PULL TO DOORS. PL-1 PL-2 PL-1 PL-2 PL-2 3' - 0 " SHAMPOO BOWL SINK HUNG FROM P.LAM BACK WALL PANEL TO DIMENSIONS INDICATED. VENDOR TO SUPPORT OFF CASEWORK EACH SIDE SO AS TO SUPPORT SHAMPOO BOWL SINK FIXTURE AS NECESSARY. HAIR TRAP (MUST BE INSTALLED STRAIGHT & TRUE, PERPENDICULAR TO CABINET AS INDICATED, SANITARY ROUGH-IN MUST BE PROPERLY LOCATED OR WILL BE SUBJECT TO CHANGE UPON REVIEW). WALL PARTITION AS SCHEDULED. SHAMPOO BOWL SINK AS SCHED. COORD. MOUNTING DETAILS W/ CUT SHEETS. 1'-1" FINISHED FACE TO ALIGN W/ ADJACENT CASEWORK P.LAM WORK TOP IN 'STORED' POSITION. (SHOWN DASHED). WHITE MELAMINE CASEWORK CUBBY FOR STORAGE OF WORK TOP. 1' - 1 " WATER SUPPLY & DRAIN LINES. VFY. ELEV. W/ FIXTURE CUT SHEETS. (ALL EXPOSED PIPING SHALL BE CHROME). 2 1 / 2 " WOOD FRAMED GLASS MIRROR. 3' - 0 " 6" LINE OF CASEWORK FIXTURE BOTTOM SHOWN BEYOND. LINE OF CASEWORK FIXTURE TOP SHOWN BEYOND. 2 1/2" PLUMBING VENT STACK IN WALL. (SHOWN DASHED). SEE MECH. PLANS FOR LOCATIONS. ALL RECESSED CASEWORK SURFACES TO BE FINISHED W/ WHITE MELAMINE. WHITE MELAMINE ADJUSTABLE SHELF. REMOVABLE P.LAM WORK TOP W/ PREFINISHED 'CUT-OUTS' FOR FAUCET EQUIP. AS REQ'D. 1' - 1 0 " 1" 1' - 7 " È­ O F D R A I N ( V E R I F Y ) 1' - 1 0 " È­ O F S U P P L Y ( V E R I F Y ) PL-1 PL-2 1'-4" 3' - 0 " 6" 1' - 9 " 1" 5 3 / 4 " 1/ 4 " 2" 2' - 6 " 1'-0" 1 1/2" 2 3 / 4 " FINISHED FLOOR AS SCHED. P.LAM COUNTER TOP & EXPOSED SIDE FACES TO BE FINISHED . SCRIBE TO WALL SURFACE. BLACK 1/4" X 1/4" REVEAL. P.LAM DRAWER W/ FULL EXTENSION HARDWARE . 1" FINGER PULL. FINISH ALL SURFACES WITHIN BLACK. P.LAM DOOR PANEL . 'WHITE' MELAMINE ADJUSTABLE SHELF. WALL BASE AS SCHED. WALL PARTITION AS SCHEDULED. PL-4 PL-4 PL-1 4"1'-4" CASEWORK SUPPLIER TO PROVIDE 'WHITE' GROMMET AS SHOWN. COORDINATE FINAL SIZE REQ'D. W/ OWNER. CENTER ON O.A. COUNTER WIDTH. CASEWORK SUPPLIER TO PROVIDE 'BLACK' GROMMET AS SHOWN. VFY. QUANTITY REQ'D. FOR ADEQUATE VENTILATION OF TENANT'S EQUIP. CUT OUT IN BACK PANEL AGAINST WALL FOR ACCESS TO POWER/DATA OUTLETS InterlockingRock PANEL WALL ABOVE PAY STATION. GENERAL CASEWORK NOTES 1.CASEWORK SUPPLIER TO MANUFACTURE AS REQUIRED FOR CASEWORK TO BE HUNG SOLELY FROM REAR WALL PARTITION. G.C. TO PROVIDE F.R.T. SOLID WOOD BLOCKING AS DIRECTED BY MILLWORK SHOP DRAWINGS. 2.ALL INTERIOR SURFACES TO BE 'WHITE' MELAMINE FINISH, TYPICAL. 3.ALL GROMMETS REFERENCED TO BE 'WHITE', TYPICAL. SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N ARCHITECTURAL CASEWORK DETAILS A6.2 1 A6.2 1/2"=1'-0" SPA CABINET ELEVATION 2 A6.2 1/2"=1'-0" LOFT CABINET / SINK PLAN 3 A6.2 1/2"=1'-0" LOFT CABINET / SINK ELEVATION 4 A6.2 1"=1'-0" LOFT CABINET / SINK SECTION 5 A6.2 1"=1'-0" NAIL UPPER CABINET SECTION 6 A6.2 1"=1'-0" NAIL PORTABLE CABINET DETAILS 9 A6.2 1"=1'-0" SPA CABINET SECTION 10 A6.2 1"=1'-0" SPA CABINET SECTION 11 A6.2 1"=1'-0" LOFT UPPER CABINET SECTION 12 A6.2 1"=1'-0" LOFT LOWER CABINET SECTION 7 A6.2 1/2"=1'-0" PAY STATION ELEVATIONS 8 A6.2 1"=1'-0" PAY STATION SECTION 3'-0 " MIN . O V E R L A P DASHED LINE INDICATES (2) METAL TRACKS ADJOINING MECHANICAL FASTENERS TYPICAL WALL TOP TRACK TYP. METAL STUD FRAMING OVERLAP AT SPLICE LIMITING HEIGHT TABLE FOR UNBRACED STUDS Stud Stud Stud Stud Maximum Width Type Gauge Spacing Height 1-5/8"158ST25 25 16"9'-6" 158ST25 25 24"7'-3" 2-1/2"212ST25 25 16"12'-6" 212ST25 25 24"10'-9" 212ST22 22 16"13'-0" 212ST22 22 24"11'-6" 212ST20 20 16"14'-0" 212ST20 20 24"12'-3" 3-5/8"358ST25 25 16"16'-0" 358ST25 25 24"13'-6' 358ST22 22 16"17'-3" 358ST22 22 24"15'-0" 358ST20 20 16"18'-3" 358ST20 20 24"16'-0" 6"600ST25 25 16"20'-0" 600ST25 25 24"15'-0" STUD FRAMING NOTES 1.TABLE BELOW IS BASED ON UNIVERSAL INDUSTRIES, UNIMAST (USG) CORP.'S LIMITING HEIGHT TABLES FOR UNBRACED STUDS SPACED 16" & 24" O.C. (SYSTEM FOLDER SA-923 1990 EDITION), REQUIREMENT FOR 5 PSF LATERAL PRESSURE & 1/240 ALLOWABLE DEFLECTION FOR FLEXIBLE FINISHES W/ 1 LAYER OF GYP. BD. PER SIDE OF STUD. 2.SCHEDULED HEIGHTS MAY BE INCREASED BY 50% WHERE THE STUDS ARE DIAGONALLY BRACED AT THE MAXIMUM HEIGHT POINT TO THE STRUCTURE ABOVE @ 4'-0" O.C. 3.CAUTION! WHEN USING STUDS MANUFACTURED BY A COMPANY OTHER THEN USG, VERIFY MANUFACTURER'S STUD STRENGTH AND LIMITING HEIGHT. ADJUST GAUGE & MAXIMUM HEIGHT RECOMMENDED BY MFR.'S CURRENT PRINTED SPECIFICATION. 4.SEE DETAIL 3/A6.3 FOR TYPICAL METAL FRAMING CONFIGURATION AT TOP OF WALL WHERE TWO TOP TRACKS ADJOIN. a.SEE TYP. WALL FRAMING FOR GAUGE OF STUDS. VERIFY LENGTH, HEIGHT, LOCATION OF BACKING PLATE, & NUMBER. b.REQUIRED WITH ACCESSORY MANUFACTURERS. USE #12 SELF TAPING SHEET METAL SCREWS WHEN ATTACHING ITEMS TO BACKING PLATE. c.WALL STUD FLANGES ARE CONTINUOUS AT BACKING PLATE. 1/ 2 " D E E P G A P CONT. 3 5/8" X 20 GA. TRACK WITH (1) #12 SCREW IN EACH FLANGE OF EACH STUD CONT. 18 GA DEEP LEG DEFLECTION TRACK (1 1/2" MIN. DEEP LEGS). CONNECT TO ROOF STRUCTURE WITH (2) #12 SCREWS @ 16" O.C. NOTE: ALL CONNECTIONS TO STRUCTURE ABOVE TO BE ATTACHED TO TOP CHORD OF STEEL TRUSS OR TO A HORIZONTAL MOUNTING PLATE RUNNING BETWEEN THE TOP CHORD OF STEEL TRUSSES. DO NOT ATTACH TO DECK. UNDERSIDE OF FLOOR OR ROOF STRUCTURE ABOVE. SEE GENERAL "NOTE" ON ATTACHMENT BELOW. P.LAM COUNTER TOP & EXPOSED SIDE FACES TO BE FINISHED . BLACK 1/4" X 1/4" REVEAL. P.LAM DRAWER W/ FULL EXTENSION HARDWARE . PL-1 CASEWORK SUPPLIER TO PROVIDE 'WHITE' GROMMET AS SHOWN. COORDINATE FINAL SIZE REQ'D. W/ OWNER. CENTER ON O.A. COUNTER WIDTH. CUT OUT IN BACK PANEL AGAINST WALL FOR ACCESS TO POWER/DATA OUTLETS 1 1/2"4" 4' - 8 " 2' - 7 " 5" B1 3/4" MDO PLYWD. SHALL BE .PL-4 PREFIN. 3/4" MDO PLYWD. WAY FINDING WALL, ALL SIDES .PL-4 4"5"1'-1" 1' - 1 1 " 1" 5 3 / 4 " 1/ 4 " 2" 1'-0" 8" 1 1/2" 2 3 / 4 " 1'-4 1/2" 4" 1" FINGER PULL. FINISH ALL SURFACES WITHIN BLACK. P.LAM DOOR PANEL . 'WHITE' MELAMINE ADJUSTABLE SHELF. PL-4 PL-4 ALL EXPOSED 3/4" MDO PLYWD. SHALL BE .PL-4 ALL INTERIOR SURFACES TO BE 'WHITE' MELAMINE FINISH, TYP. 1 1/2"4" B1 POWER & DATA FROM UNDER SLAB- SEE ELEC. PLANS. PL-4 A6.3 11PREFINISHED 3/4" MDO PLYWD. WAY FINDING WALL, ALL SIDES . 3/ 4 " 3 1 / 2 " 1'-11"1'-11" PL-1CABINET DOOR SWING SHOWN DASHED BELOW. 'WHITE' GROMMET LOCATION @ REAR OF PAY STATION. CENTER ON COUNTER TOP WIDTH AS SHOWN. NOTE: CASEWORK CONTRACTOR TO COORDINATE WITH G.C. FOR G.C. PROVIDED STL. REQ'D. TO STIFFEN MILLWORK. 1' - 0 " A4.2 7 A4.2 8 LED/LCD DISPLAY ON WALL MOUNT. G.C. TO COORD. POWER / DATA REQ'D. WITH CASEWORK SUPPLIER & ELECTRICAL CONTRACTOR. NO EXPOSED OUTLETS OR CONDUIT / WIRES PERMITTED. TO P OF DI S P L A Y SALON LOFTS GRAPHIC PUCK SUPPLIED & INSTALLED BY SALON LOFTS. LED/LCD DISPLAY ON WALL MOUNT. G.C. TO COORD. POWER / DATA REQ'D. WITH CASEWORK SUPPLIER & ELECTRICAL CONTRACTOR. NO EXPOSED OUTLETS OR CONDUIT / WIRES PERMITTED. 3/4"3 1/2"3/4" 3/ 4 " 1' - 8 1 / 2 " 3/ 4 " 1' - 1 0 " WAY FINDING MILLWORK BY CASEWORK SUPPLIER. G.C. TO COORDINATE & INSTALL AS REQ'D. PULL-OUT CHECK LEDGE . 4'-8" OUTLET & DATA JUNCTION BOX FOR PAY STATION EQUIPMENT- SEE ELEC. 2' - 0 " OUTLET & DATA JUNCTION BOX FOR LED/LCD DISPLAY- SEE ELEC. 4' - 0 " 3 1 / 2 " PULL OUT CHECK LEDGE .PL-1 PL-4 A6.3 10 A4.2 7 WAY FINDING MILLWORK BY CASEWORK SUPPLIER. G.C. TO COORDINATE & INSTALL AS REQ'D. 3'-10"5"5" 4 7 / 8 " PAINTED GYP. BD. WALL FINISH AS SCHED. FASTEN WAY FINDING MILLWORK BACK TO WALL AS REQ'D. 1 1/2"4" 4' - 8 " 2' - 7 " 5" B1 ALL EXPOSED 3/4" MDO PLYWD. SHALL BE .PL-4 PREFIN. 3/4" MDO PLYWD. WAY FINDING WALL, ALL SIDES .PL-4 4"4 1/4" 4 1/4"4" LED/LCD DISPLAY ON WALL MOUNT. G.C. TO COORD. POWER / DATA REQ'D. WITH CASEWORK SUPPLIER & ELECTRICAL CONTRACTOR. NO EXPOSED OUTLETS OR CONDUIT / WIRES PERMITTED. TO P OF DI S P L A Y SALON LOFTS GRAPHIC PUCK SUPPLIED & INSTALLED BY SALON LOFTS. OUTLET & DATA JUNCTION BOX FOR LED/LCD DISPLAY. POWER / DATA FROM WALL BEHIND. SEE ELEC. PLANS. 4' - 0 " FLOOR InterlockingRock PANELS .M24 3 1 / 2 " 3/ 4 " NOTE: CASEWORK CONTRACTOR TO COORDINATE WITH G.C. FOR G.C. PROVIDED STL. REQ'D. TO STIFFEN MILLWORK. PREFINISHED 3/4" MDO PLYWD. WAY FINDING WALL, ALL SIDES . LED/LCD DISPLAY ON WALL MOUNT. G.C. TO COORD. POWER / DATA REQ'D. WITH CASEWORK SUPPLIER & ELECTRICAL CONTRACTOR. NO EXPOSED OUTLETS OR CONDUIT / WIRES PERMITTED. 3/4"3 1/2"3/4" 3/ 4 " 7 1 / 2 " 8 1 / 4 " InterlockingRock PANELS (TYP. AT EACH SIDE). M24 T.O. / WALL FINISH EL.=9'-6" A.F.F. / SEE FINISH PLAN PARTITION/DEMISING WALL AS SCHED. WALL FINISH AT WALLS TO EXIST. ROOF DECK P2 P1/P6 (VARIES / VERIFY) P1 P6 P2 P1 / P 6 (V F Y . ) TAPED-IN MTL. 'J' BEAD OR 'TEAR STRIP' EA. SIDE OF WALL- PROVIDED & INSTALLED BY G.C. 2" T.O. GYP. BD. EL.=9'-6" A.F.F. SEE PLAN PARTITION WALL AS SCHED. WALL FINISH AT PARTIAL HEIGHT WALLS CONDUITS TO BE CONCEALED IN WALL TROUGH. CONDUIT IS NOT TO BE EXPOSED UNLESS NOTED OTHERWISE, TYP. CONT. 20 GA. DEEP LEG TRACK (UPSIDE DOWN- 2" DEEP LEGS) CONNECTED TO MTL. STUD WALL FRAMING TOP TRACK. SEE ELEVATIONS FOR LOCATIONS & SIZES REQ'D. ELEC. CONTRACTOR TO INSTALL LINEAR LED FLEX FIXTURES TO MILLWORK LOCATED SUCH THAT OWNER SUPPLIED GRAPHIC PANEL CAN BE INSTALLED IMMEDIATELY ADJACENT TO LIGHT FIXTURES AS INDICATED. COORDINATE EXACT FIXTURE PLACEMENT ON SITE TO MAXIMIZE LIGHT THROW FROM FIXTURE ONTO ADJACENT WALL SURFACES. 1/4" PROTECT EXPOSED P.LAM EDGES FROM DAMAGE. GR A P H I C P A N E L 3" RUN AT BACKSIDE AND EDGES (PROJECTING 1/4" PAST FRONT FACE OF PANEL) OF GRAPHIC DISPLAY PANEL. PL-3 SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N ARCHITECTURAL DETAILS A6.3 1 A6.3 N.T.S. STUD LIMITS & FRAMING NOTES 2 A6.3 1 1/2"=1'-0" NON-RATED DEFLECTION DETAIL 3 A6.3 1/2"=1'-0" METAL FRAMING SPLICE DETAIL 6 A6.3 NOT USED 7 A6.3 1 1/2"=1'-0" ENLARGED WAY FINDING MILLWORK PLAN 8 A6.3 NOT USED 11 A6.3 1"=1'-0" WAY FINDING MILLWORK SECTION10 A6.3 1"=1'-0" WAY FINDING MILLWORK SECTION9 A6.3 1 1/2"=1'-0" ENLARGED WAY FINDING MILLWORK PLAN 4 A6.3 3"=1'-0" PARTIAL HEIGHT WALL DETAILS 5 A6.3 6"=1'-0" GRAPHIC DISPLAY DETAIL A6.0 3sim. WALL FINISH TRANSITION AS SCHEDULED. FINISHES RETURN/ WRAP JAMB, TYP. NOTE: SEE PLAN FOR TRUE CONFIGURATION. WALL FINISH AS SCHED. 1/2" CLEAR TEMPERED GLAZING. LINE OF FINISHED FLOOR.A6.0 9sim.WALL BASE AS SCHED. GLAZING BASE. FIN. WDW. HEAD EL. = 7'-10" TOP OF FLOOR EL. = 0'-0" 4'-0" (3'-0" @ SIM.) FINISHED OPENING VFY. W/ SHEET A2.0 3"3" A6.4 3 TOP OF WALL EL. = 9'-6"F.R.T. SOLID 2x WD. BLKG. SHOWN DASHED AS REQ'D. FOR DOOR HARDWARE INSTALLATION, TYP. HEAVY DUTY TRACK MECH. FASTENED TO F.R.T. 2x WD. BLKG. IN WALL PARTITION PER MFR. INSTRUCTIONS. NOTE: SEE ELEVATIONS FOR TRACK LOCATIONS. BUMPER STOP AT EA. END OF TRACK BY TRACK SUPPLIER. A B C FOR TYP. NOTES AND INFORMATION, REFER TO LOFT TRACK BLOCKING ELEVATION A. 6'-10" 5"EQUAL EQ. TYP. EQ. TYP.EQ . TY P . EQ . TY P . 5"EQUAL 10'-0" 5"EQUAL EQUAL EQUAL 5" EQ. TYP. EQ. TYP.EQ . TY P . EQ . TY P . A 8'-6" 5"EQUAL EQUAL 5"EQUAL FOR TYP. NOTES AND INFORMATION, REFER TO LOFT TRACK BLOCKING ELEVATION A. 2 1 / 4 " T. O . D O O R EQ. TYP. EQ. TYP.EQ . TY P . EQ . TY P . 2 1 / 4 " T. O . D O O R 2 1 / 4 " T. O . D O O R D FOR TYP. NOTES AND INFORMATION, REFER TO LOFT TRACK BLOCKING ELEVATION A. 5"EQUAL 5"EQUAL 6'-0" EQ. TYP. EQ. TYP.EQ . TY P . EQ . TY P . 2 1 / 4 " T. O . D O O R LIGHT PER SCHED.- SUSPENDED FROM STRUCT. ABOVE. B.O. GYP. BD. 9'-0" A.F.F. T.O. GYP. BD. 9'-6" A.F.F. THREADED ROD HANGERS @ MAX. 4'-0" O.C. DESIGN & CONNECTIONS TO MTL. STUDS BY OTHERS. SEE DETAIL 5/A6.1 PAINT . VARIES/ SEE PLAN EXISTING STEEL JOISTS. G.C. TO VFY. LOCATIONS, TYPICAL. PAINT . UNI-STRUT FRMG. OR APPROVED EQ. AT THREADED ROD HANGERS, TYP. DESIGN BY OTHERS. PAINT .P2 6" P2 P3P3P3 P2 5/8" GYP. BD. ON 3 5/8" MTL. STUD @ 24" O.C. SOFFIT FRMG. W/ MTL. CORNER BEADS AND / OR 'TEAR STRIPS' AS REQ'D. VARIES/ SEE PLAN 3"3" TYP. ALL SIDES7" WHERE INDICATED- SEE DETAIL 6/A6.4. 4'-0" (3'-0" @ SIM.) VERIFY W/ SHEET A2.0 "LOFT" SIDE A6.4 2 NOTE: SEE PLAN FOR TRUE CONFIGURATION. WALL SYSTEM AS SCHEDULED. LINE OF FLOOR FINISH BELOW, SEE FINISH PLAN FOR DETAILS. GLAZING BASE AS NOTED, SEE DETAIL 9SIM./A6.0. LINE OF SOFFIT / HEADER CONSTR. ABOVE SHOWN DASHED. "HALLWAY" SIDE 4" TY P . 3"3" F1 F2 6" LED LINEAR WALL WASH FIXTURE WITH ADJUSTABLE HINGED CLIP (LENGTHS AS INDICATED ON SHEET A3.0) SUPPLIED BY SALON LOFTS & INSTALLED BY G.C. TO FACE OF FLOATING GYP. BD. CEILING. CENTER & ANGLE FIXTURE ALONG InterlockingRock PANELS. COORD. EXACT MOUNTING LOCATION WITH SALON LOFTS' REPRESENTATIVE. 1" 7" InterlockingRock PANELS OVER GYP. BD. WALL SURFACE FROM 3'-0" A.F.F. TO 9'-6" A.F.F. INSTALL PER MFR'S. INSTRUCTIONS. PAINT (FLAT). M24 P3 SATIN ALUM. (AE) TILE EDGE TRIM - SCHLUTER-RENO RAMP. F1EXIST. CONC. FLOOR / VINYL SHEET FLOOR SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N ARCHITECTURAL DETAILS A6.4 2 A6.4 1/2"=1'-0" GLAZING ELEVATION 3 A6.4 1 1/2"=1'-0" ENLARGED GLAZING PLAN1 A6.4 3/4"=1'-0" LOFT TRACK BLOCKING ELEVATIONS 4 A6.4 6"=1'-0" FLOOR TRANSITION DETAIL 5 A6.4 1"=1'-0" SOFFIT DETAIL 6 A6.4 3"=1'-0" DISPLAY WALL LIGHTING DETAIL TABLE OF CONTENTS DIVISION 0: CONDITIONS OF THE CONTRACT 00700 GENERAL CONDITIONS (AIA A201-1997) 00800 SUPPLEMENTARY CONDITIONS DIVISION 1: GENERAL REQUIREMENTS 01100 SUMMARY OF WORK 01300 ADMINISTRATIVE REQUIREMENTS 01400 QUALITY REQUIREMENTS 01500 TEMPORARY FACILITIES AND CONTROLS 01600 PRODUCT REQUIREMENTS 01630 SUBSTITUTIONS AND PRODUCT OPTIONS 01700 EXECUTION REQUIREMENTS 01735 SELECTIVE DEMOLITION 01800 SYSTEMS DEMONSTRATION DIVISION 2:SITE CONSTRUCTION (NOT USED) DIVISION 3:CONCRETE 03300 CAST-IN PLACE CONCRETE 03540 CEMENTITIOUS UNDERLAYMENT DIVISION 4:MASONRY (NOT USED) DIVISION 5:METALS 05500 METAL FABRICATIONS 05700 ORNAMENTAL METALS DIVISION 6: WOOD AND PLASTICS 06105 MISCELLANEOUS ROUGH CARPENTRY 06200 FINISH CARPENTRY 06400 ARCHITECTURAL WOODWORK DIVISION 7:THERMAL AND MOISTURE PROTECTION 07210 INSULATION 07560 ROOF REPAIRS 07600 FLASHING AND SHEET METAL 07810 PATCHING EXISTING FIREPROOFING 07840 FIRESTOPPING 07900 JOINT SEALERS DIVISION 8:DOORS AND WINDOWS 08110 STEEL DOORS AND FRAMES 08200 WOOD DOORS AND FRAMES 08310 ACCESS DOORS AND PANELS 08411 ALUMINUM FRAMED ENTRANCES & STOREFRONTS 08620 UNIT SKYLIGHTS 08700 HARDWARE 08810 GLAZING DIVISION 9:FINISHES 09260 GYPSUM BOARD ASSEMBLIES 09300 TILE 09510 ACOUSTICAL CEILINGS 09650 RESILIENT TILE FLOORING 09655 RESILIENT SHEET FLOORING 09680 CARPET 09900 PAINTS AND COATINGS DIVISION 10: SPECIALTIES 10520 FIRE EXTINGUISHER AND CABINETS 10810 TOILET ACCESSORIES DIVISION 11: EQUIPMENT (NOT USED) DIVISION 12: FURNISHINGS (NOT USED) DIVISION 13: SPECIAL CONSTRUCTION (NOT USED) DIVISION 14: CONVEYING SYSTEMS (NOT USED) DIVISION 15: MECHANICAL (REFER TO MECHANICAL DRAWINGS) DIVISION 16: ELECTRICAL (REFER TO ELECTRICAL DRAWINGS) DIVISION ZERO: CONDITIONS OF THE CONTRACT SECTION 00700 - GENERAL CONDITIONS A. GENERAL CONDITIONS: THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, AIA DOCUMENT A201, 1997 EDITION, IS A PART OF THIS CONTRACT, AND SHALL GOVERN WORK. 1.A COPY WILL BE MADE AVAILABLE BY ARCHITECT UPON REQUEST. SECTION 00800 - SUPPLEMENTARY CONDITIONS A.CONDITIONS AND REQUIREMENTS: GENERAL CONDITIONS, SUPPLEMENTARY CONDITIONS AND DIVISION 1, GENERAL REQUIREMENTS CONTAIN INFORMATION NECESSARY FOR COMPLETION OF EVERY PART OF PROJECT. B.DIVISION 1: WHERE PROVISIONS OF GENERAL CONDITIONS RELATE TO PROJECT ADMINISTRATION OR WORK-RELATED REQUIREMENTS OF THE CONTRACT, THOSE PARAGRAPHS ARE EXPANDED IN DIVISION 1. C.SUBCONTRACTORS: CONTRACTOR AGREES TO BIND SUBCONTRACTORS AND MATERIAL SUPPLIERS TO TERMS OF GENERAL AND SUPPLEMENTARY CONDITIONS, INCLUDING ARBITRATION. D.PAYMENTS: SEE CONSTRUCTION CONTRACT. E.INSURANCE: AS APPROVED BY LANDLORD/TENANT. F.MISCELLANEOUS DEFINITIONS: 1.APPROVED: REQUIRES WRITTEN ACTION BY ARCHITECT AS DOES TERMS SUCH AS DIRECTED, SELECTED, REQUIRED, ORDERED, DESIGNATED, ACCEPTED, ACCEPTABLE, AND SATISFACTORY. 2.FURNISH: SUPPLY AND DELIVER TO PROJECT, UNLESS OTHERWISE STATED IN GREATER DETAIL. 3.INSTALL: OPERATIONS AT PROJECT, FROM INSPECTING AND UNLOADING, TO COMPLETION IN PLACE, READY FOR INTENDED USE. 4.PROVIDE: FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE, UNLESS OTHERWISE STATED IN GREATER DETAIL. DIVISION ONE: GENERAL REQUIREMENTS SECTION 01100 - SUMMARY OF WORK A.SCOPE: PROJECT CONSISTS OF CONSTRUCTION OF THE 'SALON LOFTS' FACILITY AS INDICATED IN CONTRACT DOCUMENTS. 1.ITEMS NOTED "NIC" (NOT IN CONTRACT) WILL BE FURNISHED AND INSTALLED BY LANDLORD/TENANT OR UNDER SEPARATE CONTRACT. 2.HAZARDOUS MATERIALS: NOT IN CONTRACT; LANDLORD WILL PROVIDE FOR HANDLING OF HAZARDOUS MATERIALS UNDER SEPARATE CONTRACT PRIOR TO THIS PROJECT. IF HAZARDOUS MATERIALS ARE SUSPECTED, NOTIFY OWNER IMMEDIATELY. B.WORK SEQUENCE: COORDINATE CONSTRUCTION SCHEDULE, OPERATIONS AND USE OF PREMISES WITH BUILDING MANAGEMENT. C.CONTRACTOR USE OF PREMISES: LIMIT TO AREAS INDICATED ON DRAWINGS AND AS SPECIFIED; LIMIT ACCESS AS DIRECTED BY TENANT & LANDLORD. D.LINES AND LEVELS ENGINEERING: ESTABLISH LINES AND LEVELS BY USE OF RECOGNIZED ENGINEERING PRACTICES. LOCATE AND PROTECT CONTROL AND REFERENCE POINTS. E.REGULATORY REQUIREMENTS: PROJECT HAS BEEN DESIGNED IN ACCORDANCE WITH APPLICABLE CODES. COMPLY WITH CODE REQUIREMENTS FOR CONSTRUCTION. INFORM ARCHITECT OF DISCREPANCIES OBSERVED OR NOTED BY OTHERS. F.STANDARDS: COMPLY WITH STANDARDS REFERENCED EXCEPT WHERE MORE RIGID REQUIREMENTS ARE REQUIRED BY CODE. DATE OF STANDARD IS THAT IN EFFECT AS OF DATE DOCUMENTS ARE ISSUED, EXCEPT WHEN SPECIFIC DATE IS SPECIFIED. G.TENANT FURNISHED CONTRACTOR INSTALLED ITEMS: TENANT WILL ARRANGE FOR AND PAY FOR PRODUCT AS INDICATED ON DRAWINGS TO BE DELIVERED TO PROJECT SITE FOR CONTRACTOR INSTALLATION. 1.CONTRACTOR SHALL INSPECT, RECEIVE, UNLOAD, STORE, INSTALL AND FINISH. SECTION 01300 - ADMINISTRATIVE REQUIREMENTS A.PROCEDURES: CONTRACTOR SHALL REVIEW AND APPROVE SUBMITTALS PRIOR TO SUBMITTING TO TENANT'S PROJECT MANAGER; INFORM TENANT'S PROJECT MANAGER IN WRITING AT TIME OF SUBMISSION OF ANY PROPOSED DEVIATION FROM CONTRACT DOCUMENTS. 1.SUBMITTAL BY CONTRACTOR REPRESENTS THAT FIELD MEASUREMENTS, FIELD CONSTRUCTION CRITERIA, MATERIALS, CATALOG NUMBERS AND SIMILAR DATA HAVE BEEN DETERMINED AND VERIFIED BY CONTRACTOR. 2.REVIEW OF SUBMITTALS BY TENANT'S PROJECT MANAGER SHALL BE FOR DESIGN CONCEPT ONLY AND SHALL NOT BE CONSTRUED AS APPROVING DEPARTURES FROM CONTRACT DOCUMENTS. B.CONSTRUCTION PROGRESS SCHEDULE: BAR CHARTS OR CONTRACTOR'S STANDARD COMPUTERIZED SCHEDULES, UPDATED REGULARLY, NO LESS THAN MONTHLY. C.SCHEDULE OF VALUES: AIA FORM G703 OR APPROVED FORMAT. D.SHOP DRAWINGS: SUBMIT THREE PRINTS; PROVIDE FOR CUSTOM PRODUCTS AND PRODUCTS NOT FULLY IDENTIFIED BY PRODUCT DATA. E.PRODUCT DATA: SUBMIT NUMBER REQUIRED BY CONTRACTOR PLUS TWO FOR TENANT'S PROJECT MANAGER; INDICATE ITEM TO BE USED WHERE DATA FOR MORE THAN ONE PRODUCT OR OPTION IS INCLUDED; PROVIDE FOR EACH STOCK MANUFACTURED ITEM. F.SAMPLES: PROVIDE SAMPLES FOR EACH TYPE OF EXPOSED FINISH, COLOR, AND TEXTURE; MINIMUM SIZE 6", MAXIMUM SIZE 12" UNLESS OTHERWISE SPECIFIED; SUBMIT ONE SAMPLE FOR ARCHITECT TO RETAIN, ONE SAMPLE FOR FIELD OFFICE, AND NUMBER REQUIRED BY CONTRACTOR. G.MANUFACTURER'S CERTIFICATES: PROVIDE TWO. H.COORDINATION: COORDINATE USE OF PREMISES AND ACCESS TO SITE UNDER DIRECTION OF LANDLORD/TENANT; COORDINATE WORK TO ASSURE EFFICIENT AND ORDERLY SEQUENCE OF INSTALLATION OF CONSTRUCTION ELEMENTS. 1.MAKE PROVISIONS FOR TENANT INSTALLED ITEMS AND FOR SEPARATE CONTRACTS. 2.VERIFY CHARACTERISTICS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK HAVING INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTION TO, AND PLACING SUCH EQUIPMENT IN SERVICE. 3.COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK; CONCEAL PIPES, DUCTS, AND WIRING IN FINISHED AREAS; COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH FINISHES. I.PROJECT MEETINGS: SCHEDULE AND ADMINISTER MEETINGS, MAKE PHYSICAL ARRANGEMENT, PREPARE AGENDA, PRESIDE AT MEETINGS AND RECORD MINUTES. SECTION 01400 - QUALITY REQUIREMENTS A.GENERAL: MAINTAIN QUALITY CONTROL OVER SUPPLIERS, MANUFACTURERS, PRODUCTS, SERVICES, SITE CONDITIONS AND WORKMANSHIP. B.MANUFACTURER'S FIELD SERVICES: WHEN SPECIFIED IN RESPECTIVE SPECIFICATION SECTIONS, REQUIRE MANUFACTURER OR SUPPLIER TO HAVE QUALIFIED PERSONNEL PROVIDE ON-SITE OBSERVATIONS AND RECOMMENDATIONS. 1.REPRESENTATIVE SHALL: A. OBSERVE FIELD CONDITIONS, INCLUDING CONDITIONS OF SURFACES. OBSERVE QUALITY OF WORKMANSHIP AND METHODS OF INSTALLATION. B. PROVIDE RECOMMENDATIONS FOR INSTALLATION AND WORKMANSHIP. C. WHERE REQUIRED, START, TEST, AND ADJUST EQUIPMENT AS APPLICABLE. D. SUBMIT WRITTEN REPORT TO TENANT'S PROJECT MANAGER OF OBSERVATIONS. C.MOCK-UPS: CONSTRUCT FIELD SAMPLES AND MOCK-UPS ON SITE AS REQUIRED. D.TESTING LABORATORY SERVICES: TESTING SHALL BE BY AN APPROVED TESTING LABORATORY, AS REQUIRED BY SPECIFICATIONS AND BY APPLICABLE CODES. 1.TESTING REQUIRED WILL BE PAID FOR BY TENANT EXCEPT RETESTING WILL BE PAID FOR BY CONTRACTOR WHERE REQUIRED BY FAILURE TO MEET ORIGINAL TESTS. 2.CONTRACTOR SHALL FURNISH MATERIALS AND SAMPLES FOR TESTS AND SHALL ASSIST TESTING LABORATORY AS REQUESTED. SECTION 01500 - TEMPORARY FACILITIES AND CONTROLS A.GENERAL: PROVIDE TEMPORARY CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS AS REQUIRED TO COMPLETE PROJECT IN ACCORDANCE WITH CONTRACT DOCUMENTS AND TO CONFORM WITH REQUIREMENTS OF APPLICABLE AUTHORITIES. 1.CONTRACT GOVERNING AUTHORITIES TO ESTABLISH EXTENT OF TEMPORARY FACILITIES AND TEMPORARY CONTROLS REQUIRED BY AUTHORITIES. B.TEMPORARY POWER: PROVIDE POWER SERVICE AND LIGHTING REQUIRED FOR OPERATIONS, WITH BRANCH WIRING AND DISTRIBUTION BOXES LOCATED TO ALLOW SERVICE AND LIGHTING BY MEANS OF CONSTRUCTION-TYPE POWER CORDS. C.TEMPORARY WATER AND SANITARY SERVICES: PROVIDE AND MAINTAIN REQUIRED DRINKING WATER AND SANITARY FACILITIES WITH ENCLOSURES. D.NOISE, DUST, AND POLLUTION CONTROL: PROVIDE MATERIALS AND EQUIPMENT NECESSARY TO COMPLY WITH LOCAL REQUIREMENTS FOR NOISE, DUST, AND POLLUTION CONTROL. E.BARRIERS: PROVIDE AS REQUIRED TO PROTECT ADJACENT PROPERTIES FROM DAMAGE FROM OPERATIONS; AND AS REQUIRED BY GOVERNING AUTHORITIES. 1.FENCE: MINIMUM 8'-0" COMMERCIAL CHAIN LINK OR SOLID WOOD CONSTRUCTION FENCE; EQUIP WITH GATES WITH LOCKS. SEE PLANS. 2.SECURITY: MAINTAIN SITE AND MATERIALS SECURE DURING CONSTRUCTION PERIOD. F.CLEANING: CONTROL ACCUMULATION OF WASTE MATERIALS AND RUBBISH; DISPOSE OF OFF-SITE AT INTERVALS APPROVED BY TENANT'S PROJECT MANAGER AND ACCEPTABLE TO APPLICABLE AUTHORITIES. G.SIGNS: SUBJECT TO APPROVAL OF TENANT'S PROJECT MANAGER. H.FIELD OFFICE: PROVIDE WEATHER-TIGHT FIELD OFFICE, WITH LIGHTING, ELECTRICAL OUTLETS, HEATING, AND VENTILATING EQUIPMENT, AND EQUIPPED WITH FURNITURE. 1.TELEPHONE SERVICE: PROVIDE TELEPHONE SERVICE AND FAX SERVICE TO SITE DURING ON-SITE CONSTRUCTION OPERATIONS. 2.TELEPHONE SERVICE: PROVIDE CELLULAR PHONE WITH ON-SITE PERSON IN CHARGE; PROVIDE PHONE NUMBER TO TENANT'S PROJECT MANAGER. I.STORAGE: LIMIT ON-SITE STORAGE TO AREAS DESIGNATED FOR CONSTRUCTION OPERATIONS AND APPROVED IN WRITING IN ADVANCE BY TENANT; PROVIDE ADDITIONAL WEATHER-TIGHT, SECURED OFF-SITE STORAGE AS REQUIRED. J.REMOVAL AND CLEANING: REMOVE CONSTRUCTION FACILITIES, CLEAN AND REPAIR DAMAGE, IN EXCESS OF CONTRACT REQUIREMENTS, CAUSED BY OPERATIONS OR USE OF TEMPORARY FACILITIES. SECTION 01600 - PRODUCT REQUIREMENTS A.CONTRACT AMOUNT: BASE ON MATERIALS AND PRODUCTS IN CONTRACT DOCUMENTS; WHERE LISTED IN CONTRACT DOCUMENTS, MATERIALS AND PRODUCTS BY MANUFACTURERS NOT LISTED SHALL NOT BE USED WITHOUT WRITTEN APPROVAL. B.PRODUCTS: COMPONENTS SUPPLIED IN QUANTITY SHALL BE INTERCHANGEABLE; PROVIDE NEW MATERIALS UNLESS OTHERWISE DIRECTED IN CONTRACT DOCUMENTS. C.INSTALLATION: INSTALL ITEMS PLUMB, LEVEL AND SECURE, AND IN CORRECT RELATION TO ADJACENT PRODUCTS; SECURE IN PLACE WITH POSITIVE ANCHORAGE DEVICES DESIGNED AND SIZED TO WITHSTAND STRESSES, VIBRATION, AND RACKING. 1.COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE SPECIFIED. D.TRANSPORTATION: TRANSPORT PRODUCTS TO AVOID PRODUCT DAMAGE, DELIVER IN UNDAMAGED CONDITION IN MANUFACTURER'S UNOPENED CONTAINERS OR PACKAGING. E.HANDLING: PROVIDE EQUIPMENT AND PERSONNEL TO HANDLE PRODUCTS BY METHODS TO PREVENT SOILING AND DAMAGE; PROMPTLY INSPECT TO ASSURE PRODUCTS ARE CORRECT, COMPLETE, AND UNDAMAGED, AND QUANTITIES ARE CORRECT. F.STORAGE: STORE MATERIAL IN ACCORDANCE WITH MANUFACTURER INSTRUCTIONS, WITH SEALS AND LABELS INTACT AND LEGIBLE. G.PROTECTION: PROVIDE COVERINGS TO PROTECT PRODUCTS FROM DAMAGE FROM TRAFFIC AND CONSTRUCTION OPERATIONS, REMOVE WHEN NO LONGER NEEDED. H.SPECIFIED PRODUCTS: FOR PRODUCTS SPECIFIED BY NAMING ONE OR MORE PRODUCTS OR MANUFACTURERS, SELECT PRODUCTS OF ANY NAMED MANUFACTURER MEETING SPECIFICATIONS. SECTION 01630 - SUBSTITUTIONS AND PRODUCT OPTION A.SUBSTITUTIONS AND PRODUCT OPTIONS: PROVIDE PRODUCTS INDICATED OR APPROVED; REQUESTS FOR SUBSTITUTIONS OF OTHER PRODUCTS WILL BE CONSIDERED IF SUBMITTED IN WRITING. 1.CONTRACTOR OPTIONS: PROVIDE PRODUCTS AND MANUFACTURERS NAMED IN SPECIFICATIONS, SUBMIT REQUEST FOR SUBSTITUTION FOR PRODUCTS AND MANUFACTURERS NOT SPECIFICALLY NAMED WHERE NAMES ARE LISTED. 2.SUBSTITUTIONS: CONTRACTOR SHALL INVESTIGATE PROPOSED SUBSTITUTIONS AND DETERMINE IF EQUIVALENT TO PRODUCTS SPECIFIED. SUBMITTALS SHALL INCLUDE COST OR TIME BENEFITS FOR SUBSTITUTIONS; FAILURE TO INDICATE COST OR TIME BENEFIT IS JUSTIFICATION FOR REJECTION. 3.CONTRACTOR'S REPRESENTATION: REQUESTS CONSTITUTE THAT CONTRACTOR HAS INVESTIGATED PROPOSED PRODUCTS AND DETERMINES IT MEETS OR EXCEEDS SPECIFIED PRODUCTS AND WAIVES CLAIMS FOR ADDITIONAL COSTS THAT SUBSEQUENTLY BECOME APPARENT. 4.ARCHITECT'S DUTIES: TENANT'S PROJECT MANAGER SHALL BE JUDGE OF ACCEPTABILITY AND RESERVES RIGHT TO REJECT PROPOSED SUBSTITUTION BASED ON INSUFFICIENT INFORMATION; USE ONLY SUBSTITUTIONS APPROVED IN WRITING. TENANT'S PROJECT MANAGER HAS THE RIGHT TO EMPLOY ARCHITECT TO EVALUATE AND APPROVE SUBSTITUTIONS. SECTION 01700 - EXECUTION REQUIREMENTS A.INSTALLER QUALIFICATIONS: INSTALLERS TO HAVE MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE INSTALLING ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT, EXCEPT FOR INDIVIDUALS IN TRAINING UNDER DIRECT SUPERVISION OF EXPERIENCED INSTALLER. B.EXAMINATION: BEGINNING INSTALLATION OF A PRODUCT SIGNIFIES INSTALLER HAS EXAMINED SUBSTRATES, AREAS, AND CONDITIONS FOR COMPLIANCE WITH MANUFACTURER REQUIREMENTS FOR TOLERANCES AND OTHER CONDITIONS AFFECTING PERFORMANCE. C.MANUFACTURER'S INSTRUCTIONS: WHEN WORK IS SPECIFIED TO COMPLY WITH MANUFACTURERS' RECOMMENDATIONS OR INSTRUCTIONS, DISTRIBUTE COPIES TO PERSONS INVOLVED, AND MAINTAIN ONE SET IN FIELD OFFICE. D.INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS UNLESS MORE RESTRICTIVE REQUIREMENTS ARE SPECIFIED. E.PROTECTION: COVER PRODUCTS SUBJECT TO DETERIORATION WITH IMPERVIOUS SHEET, PROVIDE VENTILATION TO AVOID CONDENSATION AND TRAPPING WATER. F.CUTTING AND PATCHING: CUT AND FIT COMPONENTS AS REQUIRED; PATCH DISTURBED AREAS TO MATCH ADJACENT MATERIALS AND FINISHES. 1.REFINISHING: REFINISH ENTIRE SURFACES AS NECESSARY TO PROVIDE EVEN FINISH TO MATCH ADJACENT FINISHES; FOR CONTINUOUS SURFACES REFINISH TO NEAREST INTERSECTION, FOR AN ASSEMBLY REFINISH ENTIRE UNIT. G.FINAL CLEANING: CLEAN INTERIOR AND EXTERIOR SURFACES EXPOSED TO VIEW, REMOVE TEMPORARY LABELS, STAINS, AND FOREIGN SUBSTANCES; POLISH TRANSPARENT AND GLOSSY SURFACES; VACUUM CARPETED AND SOFT SURFACES; CLEAN DUCTS; CLEAN SITE. H.SUBSTANTIAL COMPLETION: PROVIDE DOCUMENTATION STATING WORK HAS BEEN SUBSTANTIALLY COMPLETED. WHERE OWNER REQUIRES USE OF SPACE PRIOR TO FINAL COMPLETION, PROVIDE LIST OF ITEMS TO BE COMPLETED. 1.TENANT'S PROJECT MANAGER WILL REVIEW LIST OF ANY ITEMS TO BE COMPLETED AND SUPPLEMENT LIST WITH ITEMS CONSIDERED TO BE INCOMPLETE OR UNACCEPTABLE. I.FINAL COMPLETION: PROVIDE WRITTEN CERTIFICATION INDICATING WORK IS IN COMPLIANCE WITH CONTRACT DOCUMENTS, SYSTEMS HAVE BEEN TESTED AND ARE OPERATIONAL, AND WORK IS READY FOR FINAL INSPECTION. J.PROJECT RECORD DOCUMENTS: MAINTAIN COMPLETE AND UP-TO-DATE RECORD DOCUMENTS; KEEP SEPARATE FROM FIELD DOCUMENTS. SUBMIT PROJECT RECORD DOCUMENTS, MATERIAL AND FINISH DATA, OPERATION AND INSTRUCTION MANUALS, WARRANTIES AND BONDS AT COMPLETION. 1.SUBMIT BOUND IN 8-1/2" X 11" THREE RING BINDERS WITH DURABLE PLASTIC COVERS. ARRANGE IN FORMAT SIMILAR TO SPECIFICATIONS. K.WARRANTIES: PROVIDE WARRANTIES AS INDICATED, SIGNED BY CONTRACTOR AND MANUFACTURER; FORM AS APPROVED BY TENANT PRIOR TO EXECUTION. 1.WARRANTIES SHALL BE IN ADDITION TO AND NOT A LIMITATION OF OTHER RIGHTS TENANT MAY HAVE AGAINST CONTRACTOR UNDER CONTRACT DOCUMENTS AND AS PRESCRIBED BY LAW, REGARDLESS OF WORDING OF WARRANTY. SECTION 01735 - SELECTIVE DEMOLITION A.SELECTIVE DEMOLITION: REMOVE FROM SITE EXISTING MATERIALS, CONSTRUCTION AND UTILITIES AS NEEDED TO COMPLETE PROJECT. REMOVE EXISTING ELEMENTS INDICATED AND ENCOUNTERED DURING CONSTRUCTION, AS NEEDED TO COMPLETE WORK. 1.REMOVE ONLY THOSE ELEMENTS NECESSARY FOR COMPLETION OF PROJECT, REPLACE OR REPAIR ELEMENTS UNNECESSARILY REMOVED OR DAMAGED DURING CONSTRUCTION. 2.CAREFULLY REMOVE AND STORE ITEMS INDICATED FOR REUSE IN PROJECT AND COORDINATE WITH OTHER TRADES FOR MODIFICATIONS AND REINSTALLATION. 3.PROTECTION: PREVENT MOVEMENT AND SETTLEMENT OF ADJACENT STRUCTURE; PROVIDE BRACING, SHORING, AND UNDERPINNING AS NEEDED AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURES. ASSUME LIABILITY FOR SUCH MOVEMENT AND SETTLEMENT. 4.UTILITIES: CONTACT APPLICABLE UTILITY COMPANIES PRIOR TO DISCONNECTING UTILITIES; DISCONTINUE WORK IF UNEXPECTED UTILITY LINES ARE ENCOUNTERED. DETERMINE LINE SOURCE AND USE PRIOR TO REMOVAL. CAP AND IDENTIFY EXISTING UTILITY LINES REMOVED. SECTION 01800 - SYSTEMS DEMONSTRATIONS A.SUMMARY: PROJECT INCLUDES SPECIAL FACILITY START-UP PROCESS TO BRING FACILITY TO FULLY OPERATIONAL STATE, FREE OF DEFICIENCIES, IN MOST EFFICIENT AND TIMELY MANNER ACHIEVABLE. DIVISION TWO: SITE CONSTRUCTION (NOT USED) DIVISION THREE: CONCRETE SECTION 03300 - CAST IN PLACE CONCRETE A.GENERAL: PROVIDE CAST IN PLACE CONCRETE FOR SLABS ON GRADE, ALONG WITH ALL REQUIRED ACCESSORIES AND CONCRETE REINFORCEMENT MATERIALS. B.INSTALLER QUALIFICATIONS: FIRM WITH A MINIMUM 5 YEARS SUCCESSFUL EXPERIENCE, REGULARLY ENGAGED IN THE INSTALLATION OF THE SPECIFIED MATERIAL AND PROPERLY EQUIPPED. C.PERFORM WORK IN ACCORDANCE WITH ACI 301 AND ACI 318. FOLLOW RECOMMENDATIONS OF ACI 305R WHEN CONCRETING DURING HOT WEATHER, AND ACI 306R WHEN CONCRETING DURING COLD WEATHER. D.PROJECT RECORD DOCUMENTS: ACCURATELY RECORD ACTUAL LOCATIONS OF EMBEDDED UTILITIES AND COMPONENTS THAT WILL BE CONCEALED UPON COMPLETION OF CONCRETE WORK. E.FORM MATERIALS: CONTRACTOR'S CHOICE OF STANDARD PRODUCTS WITH SUFFICIENT STRENGTH TO WITHSTAND HYDROSTATIC HEAD WITHOUT DISTORTION. F.REINFORCEMENT MATERIALS AND ACCESSORIES: 1.REINFORCING STEEL: DEFORMED BILLET-STEEL BARS, ASTM A615/A615M GRADE 60. 2.STEEL WELDED REINFORCEMENT: FLAT SHEETS WITH MESH SIZE AND WIRE GAUGE AS NOTED ON DRAWINGS, ASTM A185/A185M. 3.ACCESSORIES: TIE WIRE (ANNEALED 16 GA. MIN.), CHAIRS, BAR SUPPORTS, SPACERS TO BE SIZED AND SHAPED FOR ADEQUATE SUPPORT OF REINFORCEMENT DURING CONCRETE PLACEMENT. G.CONCRETE MATERIALS: CEMENT ASTM C150, TYPE I - NORMAL PORTLAND TYPE. NOMINAL MAX. AGGREGATE SIZE FOR SLABS IS 34", FLY ASH (ASTM C618) CLASS C OR F, AND CLEAN WATER. H.ACCESSORY MATERIALS: 1.RETARDING ADMIXTURE: ASTM C494/C494M TYPE B. 2.UNDERSLAB VAPOR RETARDER: MULTI-LAYER REINFORCED POLYETHYLENE COMPLYING WITH ASTM E1745, CLASS B, WHERE INDICATED ON DRAWINGS. 3.MOISTURE RETAINING COVER: ASTM C171 - REGULAR CURING PAPER. 4.LIQUID CURING COMPOUND: ASTM c309, TYPE 1, CLEAR OR TRANSLUCENT. I.CONCRETE MIX DESIGN FOR SLABS ON GRADE: COMPRESSIVE STRENGTH OF 4,000 PSI @ 48 HOURS, FLY ASH CONTENT - 50% MAX., MAX. AGGREGATE SIZE IS 34", SLUMP LIMIT 3-4 INCHES, AIR CONTENT 0%. J.COORDINATE PLACEMENT OF EMBEDDED ITEMS WITH ERECTION OF CONCRETE FORMWORK, PLACEMENT OF FORM, REINFORCEMENT ACCESSORIES, AND CONCRETE PLACEMENT. K.INSTALL REINFORCEMENT WITH NOT LESS THAN MINIMUM COVERAGE REQUIRED FOR PROTECTION, WELDED WIRE REINFORCEMENT TO BE INSTALLED IN MAX. LENGTHS POSSIBLE WITH OFFSET END LAPS IN BOTH DIRECTIONS AND TIE WIRED TOGETHER. L.PLACE CONCRETE FLOOR SLABS IN ACCORDANCE WITH ACI 302.1R, ENSURE REINFORCEMENT, INSERTS, ETC. WILL NOT BE DISTURBED DURING CONCRETE PLACEMENT. PLACE CONCRETE CONTINUOUSLY BETWEEN PREDETERMINED EXPANSION, CONTROL AND CONSTRUCTION JOINTS. DO NOT ALLOW COLD JOINTS TO OCCUR. VIBRATE TO ELIMINATE AIR POCKETS, ETC. M.SCREED FLOORS AND SLABS ON GRADE LEVEL, MAINTAINING A SURFACE FLATNESS OF MAXIMUM 18 INCH IN 10 FT. N.FINISH CONCRETE SLAB TO FINISH REQUIREMENT OF ACI 302.1R - STEEL TROWEL SURFACES TO A FLUSH, LEVEL, AND SMOOTH FINISH AS REQUIRED TO ACCEPT NEW FLOOR FINISHES SPECIFIED. O.CURING AND PROTECTION: COMPLY WITH REQUIREMENTS OF ACI 308. IMMEDIATELY AFTER PLACEMENT, PROTECT CONCRETE FROM PREMATURE DURING, EXCESSIVE TEMPERATURES, AND MECHANICAL INJURY. SECTION 03540 - CEMENTITIOUS UNDERLAYMENT A.GENERAL: PROVIDE POURED CEMENTITIOUS UNDERLAYMENT SYSTEM, NOT INTENDED AS FINISHED TRAFFIC SURFACE, INCLUDING ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. B.INSTALLER: FIRM WITH MINIMUM 5 YEARS SUCCESSFUL EXPERIENCE, REGULARLY ENGAGED IN INSTALLATION OF SPECIFIED MATERIALS, PROPERLY EQUIPPED AND ACCEPTABLE TO MANUFACTURER. C.SUBMITTALS: FURNISH MANUFACTURER'S LITERATURE. D.MANUFACTURER: ARDEX, INC./K-15; W.R.BONSAL CO./SELF-LEVELING WEAR TOPPING. E.SYSTEM: POURABLE CEMENTITIOUS, HIGH-STRENGTH, FAST-SETTING, NON-SHRINK, SELF-LEVELING UNDERLAYMENT; MINIMUM 4000 PSI COMPRESSIVE STRENGTH AT 28 DAYS, ASTM C349. F.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. DIVISION FOUR: MASONRY (NOT USED) DIVISION FIVE: METALS SECTION 05500 - METAL FABRICATIONS A.GENERAL: PROVIDE MISCELLANEOUS METAL SHAPES AND FABRICATIONS AS REQUIRED AND NOT INCLUDED AS PART OF OTHER SECTIONS, WITH ANCHORS AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. B.SUBMITTALS: FURNISH SHOP DRAWINGS FOR CUSTOM FABRICATIONS, PRODUCT DATA FOR MANUFACTURED ITEMS; PROVIDE TEMPLATES FOR ANCHOR INSTALLATION BY OTHERS. C.STEEL SHAPES: ASTM A36 STEEL. D.GROUT: PROVIDE NON-SHRINK, NON-METALLIC, PRE-MIXED, FACTORY PACKAGED, NON-STAINING, NON-CORROSIVE, NON-GASEOUS GROUT; TYPE SPECIFICALLY RECOMMENDED BY MANUFACTURER FOR APPLICATIONS INDICATED. E.FASTENERS AND ROUGH HARDWARE: TYPE REQUIRED FOR SPECIFIC USAGE; PROVIDE ZINC-COATED FASTENERS FOR EXTERIOR USE OR WHERE BUILT INTO EXTERIOR WALLS. F.WELDING MATERIALS: AWS D1.1, TYPE REQUIRED FOR MATERIALS BEING WELDED. G.PAINT: PROVIDE PRIMERS AS RECOMMENDED BY PAINT MANUFACTURERS FOR SUBSTRATES AND PAINTS SPECIFIED IN SECTION 09900 - PAINTING. 1.GALVANIZING REPAIR PAINT: HIGH ZINC-DUST CONTENT PAINT FOR REGALVANIZING WELDS IN GALVANIZED STEEL. H.FABRICATION: FABRICATE ITEMS WITH JOINTS NEATLY FITTED AND PROPERLY SECURED; GRIND EXPOSED WELDS CONTINUOUS, SMOOTH AND FLUSH WITH ADJACENT FINISHED SURFACES, AND EASE EXPOSED EDGES TO APPROXIMATE 1/32" UNIFORM RADIUS. 1.MAKE EXPOSED JOINTS FLUSH BUTT TYPE, HAIRLINE JOINTS WHERE MECHANICALLY FASTENED. 2.FIT AND SHOP ASSEMBLE IN LARGEST PRACTICAL SECTIONS FOR DELIVERY. I.FINISHES: GALVANIZE AND PRIME PAINT EXTERIOR MISCELLANEOUS METAL, PRIME PAINT INTERIOR MISCELLANEOUS METAL; GALVANIZE COATING MINIMUM G90 COATING, GALVANIZED AFTER FABRICATION. 1.CLEAN SURFACES OF RUST, SCALE, GREASE AND FOREIGN MATTER PRIOR TO APPLYING GALVANIZED OR PAINTED FINISH. J.INSTALLATION: INSTALL ITEMS SQUARE AND LEVEL, ACCURATELY FITTED AND FREE FROM DISTORTION OR DEFECTS DETRIMENTAL TO APPEARANCE OR PERFORMANCE; ENSURE ALIGNMENT WITH ADJACENT CONSTRUCTION; COORDINATE WITH RELATED WORK TO ENSURE NO INTERRUPTION IN INSTALLATION. 1.SUPPLY ITEMS REQUIRING TO BE CAST INTO OR EMBEDDED IN OTHER MATERIALS TO APPROPRIATE TRADES. 2.AFTER INSTALLATION, TOUCH-UP FIELD WELDS AND SCRATCHED AND DAMAGED SURFACES; USE PRIMER CONSISTENT WITH SHOP COAT OR RECOMMENDED FOR GALVANIZED SURFACES, AS APPLICABLE. SECTION 05700 - ORNAMENTAL METALS A.GENERAL: PROVIDE CUSTOM ORNAMENTAL METAL ITEMS AS INDICATED WITH ACCESSORIES AND ATTACHMENT DEVICES AS REQUIRED FOR COMPLETE, FINISHED INSTALLATION. B.ORNAMENTAL METAL ITEMS: 1.PROVIDE BREAK METAL SHAPES AS INDICATED ON DRAWINGS. C.SUBMITTALS: FURNISH PRODUCT DATA, SHOP DRAWINGS, AND SAMPLES OF EACH EXPOSED METAL FINISH. D.FABRICATOR: FIRM WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE FABRICATING ORNAMENTAL METAL ITEMS SIMILAR TO THOSE REQUIRED FOR PROJECT. E.STAINLESS STEEL: ASTM A666, TYPE 302/304 CORROSION RESISTANT STAINLESS STEEL WITH NO. 4 SATIN DIRECTIONAL FINISH. F.ALUMINUM: MINIMUM ASTM B209, 6061-T6 PLATE AND SHEET, ASTM B221, 6063-T6 EXTRUSIONS; SIZED FOR STRENGTH AND DURABILITY CONSISTENT WITH APPLICATION INVOLVED. 1.FINISH: PROVIDE FACTORY FORMULATED POLYESTER TGIC POWDER COATING MATERIALS INTENDED FOR POWDER COATING APPLICATION CUSTOM COLOR AS DIRECTED BY ARCHITECT. G.BRACKETS AND ANCHORS: UNEXPOSED PLATES, ANGLES AND SUPPORTS MAY BE STEEL; EXPOSED ITEMS TO MATCH ORNAMENTAL METAL TYPE AND FINISH. H.FASTENERS: TYPE REQUIRED FOR SPECIFIC USAGE; PROVIDE CONCEALED FASTENERS EXCEPT WHERE SPECIFICALLY APPROVED; WHERE EXPOSED MATCH TYPE AND FINISH OF METAL BEING FASTENED. 1.CONCEALED STEEL FASTENERS: HOT-DIPPED GALVANIZED MINIMUM G90 WHERE BUILT INTO EXTERIOR WALLS OR SUBJECT TO HIGH HUMIDITY. I.FABRICATION: FABRICATE COMPONENT CONNECTIONS TO SUPPORT SPECIFIED DESIGN LOADS. 1.SELECT MATERIALS FOR STRAIGHTNESS, FREE OF DEFECTS AND IRREGULARITIES. 2.EXPOSED-TO-VIEW SURFACES EXHIBITING PITTING, SEAM MARKS, ROLLER MARKS, "OIL CANNING," STAINS, DISCOLORATIONS, AND IMPERFECTIONS ON FINISHED UNITS ARE NOT ACCEPTABLE. 3.MAKE EXPOSED JOINTS FLUSH BUTT TYPE, HAIRLINE JOINTS WHERE MECHANICALLY FASTENED; PROVIDE CONCEALED CONNECTION DEVICES WITH HIDDEN FASTENERS. 4.SEPARATE DISSIMILAR MATERIALS WITH BITUMINOUS PAINT WHERE CONCEALED, WITH PREFORMED SEPARATORS, OR SIMILAR METHOD TO PREVENT CORROSION. J.INSTALLATION: INSTALL ORNAMENTAL METAL ITEMS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, INSTALLATION INSTRUCTIONS, AND APPROVED SHOP DRAWINGS. 1.INSTALL PLUMB, TRUE AND IN CORRECT RELATION TO ADJACENT WORK, FREE FROM DISTORTION OR DEFECTS DETRIMENTAL TO APPEARANCE AND PERFORMANCE. 2.PRIOR TO SECURING CONTINUOUS ITEMS, ADJUST TO ENSURE PROPER MATCHING AT BUTT JOINTS AND CORRECT ALIGNMENT THROUGHOUT THEIR LENGTH. 3.REPAIR OR REPLACE ITEMS DAMAGED OR MARRED DURING CONSTRUCTION. DIVISION SIX: WOOD AND PLASTICS SECTION 06105 - MISCELLANEOUS ROUGH CARPENTRY A.GENERAL: PROVIDE MISCELLANEOUS BLOCKING AND PLYWOOD. B.STANDARDS: COMPLY WITH REQUIREMENTS OF AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC), AMERICAN PLYWOOD ASSOCIATION (APA), AND APPLICABLE CODE REQUIREMENTS. C.BLOCKING: COMPLY WITH PS 20; GRADED BY AN AGENCY CERTIFIED BY NATIONAL FOREST PRODUCTS ASSOCIATION (NFPA) AND OF TYPE RECOMMENDED FOR APPLICATION INVOLVED; DOUGLAS FIR OR SOUTHERN PINE; MINIMUM CONSTRUCTION GRADE S-DRY. D.PLYWOOD: PROVIDE MINIMUM APA C-D EXTERIOR (CDX) PLYWOOD; STRESS RATED WHERE SPANNING SUPPORTING MEMBERS; FIRE RETARDANT TREATED; MINIMUM 3/4" THICK UNLESS OTHERWISE INDICATED. 1.PLYWOOD STANDARD: COMPLY WITH PS1 (ANSI A199.1). 2.PLYWOOD PANEL BOARDS: PROVIDE PANEL BOARDS FOR ELECTRICAL AND COMMUNICATION PANEL BOARDS; APA C-D PLUGGED, INTERIOR TYPE PLYWOOD WITH EXTERIOR GLUE, FIRE RETARDANT TREATED; MINIMUM 1/2" THICK. E.TREATED WOOD: PRESSURE TREAT WOOD IN CONTACT WITH CONCRETE AND WITH ROOFING; FIRE TREAT WOOD CONCEALED IN INTERIOR; FIRE TREAT BLOCKING AT ROOFING WHERE REQUIRED BY APPLICABLE AUTHORITIES. 1.PRESSURE TREATED: WATER-BORNE PRESERVATIVES FOR ABOVE GROUND USE CONFORMING TO AWPA C2 AND C9. 2.FIRE TREATED: CONFORM TO AWPA C20 AND C27, INTERIOR TYPE A AT INTERIOR APPLICATIONS; PASS ASTM D2898 RAIN TEST WHERE AT EXTERIOR WALLS AND ROOF; IDENTIFY WITH FRTW. 3.KILN-DRY TREATED WOOD TO 19 % MOISTURE CONTENT AND DISCARD WARPED AND DAMAGED PIECES. F.FASTENERS: PROVIDE FASTENERS AS REQUIRED FOR COMPLETE, SECURE INSTALLATION OF MISCELLANEOUS ROUGH CARPENTRY; GALVANIZED AT EXTERIOR LOCATIONS AND PRESSURE TREATED WOOD; SIZE AND TYPE TO SUIT APPLICATION; PROVIDE WASHERS FOR NUTS AND BOLTS. G.INSTALLATION: COMPLY WITH REFERENCED STANDARDS AND APPLICABLE CODE REQUIREMENTS. 1.PLYWOOD: COMPLY WITH RECOMMENDATIONS OF AMERICAN PLYWOOD ASSOCIATION (APA) FOR FABRICATION AND INSTALLATION OF PLYWOOD WORK. 2.PLACE MISCELLANEOUS ROUGH CARPENTRY TRUE TO LINES AND LEVELS. 3.CORRELATE LOCATION SO ATTACHED WORK WILL COMPLY WITH DESIGN REQUIREMENTS AND BE PROPERLY LOCATED. 4.CONSTRUCT MEMBERS OF CONTINUOUS PIECES OF LONGEST POSSIBLE LENGTHS. 5.FIT CARPENTRY WORK TO OTHER WORK; SCRIBE AND COPE AS REQUIRED FOR ACCURATE FIT. 6.SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES BY ANCHORING AND FASTENING AS REQUIRED BY RECOGNIZED STANDARDS. 7.PROVIDE WASHERS UNDER BOLT HEADS AND NUTS IN CONTACT WITH WOOD. SECTION 06200 - FINISH CARPENTRY A.GENERAL: PROVIDE WOOD TRIM, WOOD SHELVING, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.STANDARDS: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWI)/QUALITY STANDARDS "MANUAL OF MILLWORK" STANDARDS; MINIMUM WIC/CUSTOM GRADE. C.SUBMITTALS: FURNISH PRODUCT DATA FOR MANUFACTURED ITEMS, SHOP DRAWINGS FOR CUSTOM ITEMS, SAMPLES OF EACH EXPOSED FINISH. D.CERTIFICATION: CERTIFICATION WILL NOT BE REQUIRED. E.MANUFACTURER: TO BE DETERMINED F.DELIVERY, STORAGE AND HANDLING: COMPLY WITH AWI STANDARDS AND MANUFACTURER RECOMMENDATIONS. G.WOOD TRIM: PREMIUM GRADE FOR OPAQUE PAINT FINISH; WHITE BIRCH OR POPLAR UNLESS OTHERWISE INDICATED. H.WOOD SHELVING: AWI OR WIC/CUSTOM GRADE, PARTICLE BOARD, OR HARDWOOD-EDGED PLYWOOD. I.ANCHORS, NAILS AND SCREWS: SELECT THE MATERIAL, TYPE, SIZE AND FINISH REQUIRED BY EACH SUBSTRATE FOR SECURE ANCHORAGE; PROVIDE TOOTHED STEEL OR LEAD EXPANSION BOLT SCREWS FOR DRILLED-IN-PLACE ANCHORS. J.WOOD FILLER: COLOR TO MATCH WOOD BEING FILLED. K.FABRICATION: FABRICATE FINISH CARPENTRY ITEMS IN ACCORDANCE WITH SPECIFIED QUALITY STANDARD. L.INSTALLATION: INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS; SHIM AS REQUIRED, USING CONCEALED SHIMS. M.PREPARATION FOR FIELD FINISHING: SAND WORK SMOOTH AND SET EXPOSED NAILS AND SCREWS; APPLY WOOD FILLER IN EXPOSED NAIL AND SCREW INDENTATIONS AND LEAVE READY TO RECEIVE SITE-APPLIED FINISHES. 1.SEAL CONCEALED AND SEMI-CONCEALED SURFACES; BRUSH APPLY ONLY, USING PRIMER CONSISTENT WITH FINISH COATS SPECIFIED UNDER SECTION 09900 - PAINTS AND COATINGS. SECTION 06400 - ARCHITECTURAL WOODWORK A.INSTALL TENANT FURNISHED CASEWORK AND COUNTERTOPS INDICATED TO BE TENANT FURNISHED AND PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.STANDARDS: CONFORM TO ARCHITECTURAL WOODWORK INSTITUTE (AWI)/QUALITY STANDARDS "MANUAL OF MILLWORK" STANDARDS; MINIMUM PREMIUM GRADE. C.SUBMITTALS: FURNISH PRODUCT DATA FOR CONTRACTOR FURNISHED ACCESSORIES INCLUDING SAMPLES OF EXPOSED MATERIALS. D.STORAGE AND HANDLING: COMPLY WITH MANUFACTURER RECOMMENDATIONS. E.ACCESSORIES: PROVIDE AS INDICATED AND AS REQUIRED TO INSTALL ARCHITECTURAL WOODWORK AS INDICATED; COORDINATE ACCESSORIES REQUIRED FOR INSTALLATION OF OWNER FURNISHED ARCHITECTURAL WOODWORK NOT FURNISHED WITH ARCHITECTURAL WOODWORK. F.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND REFERENCED STANDARDS. TAKE SPECIAL CARE COORDINATING INSTALLATION OF OWNER FURNISHED ARCHITECTURAL WOODWORK WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. 1.INSTALL WORK CONSISTENT WITH SPECIFIED QUALITY GRADE, PLUMB, LEVEL, TRUE AND STRAIGHT WITH NO DISTORTIONS. 2.SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK. 3.ENSURE MECHANICAL AND ELECTRICAL ITEMS AFFECTING ARCHITECTURAL WOODWORK ARE PROPERLY PLACED, COMPLETE, AND HAVE BEEN INSPECTED TENANT'S PROJECT MANAGER PRIOR TO INSTALLATION OF WOODWORK. SECURE WORK TO GROUNDS, STRIPPING AND BLOCKING WITH COUNTERSUNK, CONCEALED FASTENERS AND BLIND NAILING AS REQUIRED FOR A COMPLETE INSTALLATION. 4.SCRIBE AND CUT FOR ACCURATE FIT TO OTHER FINISHED WORK. 5.ATTACH ARCHITECTURAL WOODWORK SECURELY IN PLACE WITH UNIFORM JOINTS PROVIDING FOR THERMAL AND BUILDING MOVEMENTS. 6.ACCEPTABLE TOLERANCES: A. VARIATION FROM TRUE POSITION: MAXIMUM 1/16" AT ANY POSITION AND MAXIMUM 1/8" IN ANY 10'-0" LENGTH. B. ADJOINING SURFACES OF SAME MATERIAL: NO VARIATION PERMITTED. SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N SPECIFICATIONS SP.1 DIVISION SEVEN: THERMAL AND MOISTURE PROTECTION SECTION 07210 - INSULATION A.GENERAL: PROVIDE THERMAL INSULATION WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 1.INSULATION INTEGRAL WITH ROOFING REPAIRS IS PROVIDED WITH ROOFING, AND ACOUSTICAL INSULATION IS PROVIDED WITH GYPSUM BOARD ASSEMBLIES. B.THERMAL BATT INSULATION: OWENS CORNING/FS-25, USG/THERMAFIBER FS25, OR JOHNS MANVILLE/FSK-25; FOIL FACED VAPOR RETARDER FACED, VAPOR RETARDER TOWARD INSIDE. 1.THICKNESS/R-VALUE: AS INDICATED ON DRAWINGS. C.ACCESSORIES: PROVIDE TAPE OR PENETRATION ANCHORS WHERE REQUIRED TO ENSURE PERMANENT INSTALLATION. D.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. SECTION 07560 - ROOF REPAIRS A.GENERAL: REPAIR EXISTING ROOFING SYSTEM AS REQUIRED FOR NEW CONSTRUCTION, WITH COMPONENTS AND ACCESSORIES AS REQUIRED FOR COMPLETE WEATHERTIGHT INSTALLATION. G.C. TO USE LANDLORD'S ROOFING CONTRACTOR. B.STANDARDS: CONFORM TO NATIONAL ROOFING CONTRACTOR'S ASSOCIATION ROOFING AND WATERPROOFING MANUAL, 4TH OR 5TH EDITION. C.WARRANTY: PROVIDE FOR CORRECTING FAILURE OF ROOF REPAIRS TO RESIST PENETRATION OF WATER AND DAMAGE FROM WIND; WARRANTY PERIOD OF TWO YEARS. D.ROOFING SYSTEM: MATCH EXISTING ROOFING, NO SUBSTITUTIONS PERMITTED; PROVIDE MATERIALS CAPABLE OF MAINTAINING EXISTING WARRANTIES; CONFORM TO REQUIREMENTS OF NRCA ROOFING MANUAL. 1.SYSTEM: PROVIDE COMPLETE SYSTEM WITH ACCESSORIES AS REQUIRED FOR REPAIRS, INCLUDING INSULATION WHERE EXISTING ROOFING IS INSULATED. E.ROOF SYSTEM REPAIRS: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTRUCTIONS AND NRCA RECOMMENDATIONS FOR ROOF TYPE SPECIFIED. 1.REMOVE EXISTING ROOFING AS REQUIRED FOR PROJECT; REMOVE ONLY AS MUCH ROOFING AS CAN BE REPLACED IN SAME DAY UNLESS OTHERWISE APPROVED IN ADVANCE BY ARCHITECT. 2.INSPECT SUBSTRATES AND ROOF DECK TO ENSURE SUBSTRATES AND DECK ARE CLEAN AND SMOOTH, FREE OF DEPRESSIONS, WAVES OR PROJECTIONS, AND ARE PROPERLY SLOPED TO DRAINS, VALLEY, OR EAVES. 3.INSULATION APPLICATION: ATTACH INSULATION IN ACCORDANCE WITH INSULATION MANUFACTURER'S INSTRUCTIONS AND NRCA RECOMMENDATIONS FOR INSTALLATION OF INSULATION ON DECK INVOLVED. 4.COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF COMPOSITION TYPE BASE, WALL AND FIELD FLASHINGS. 5.COORDINATE METAL FLASHINGS AND COUNTERFLASHING. 6.COORDINATE INSTALLATION OF ROOF DRAINS AND RELATED FLASHINGS. 7.MOP IN AND SEAL FLASHINGS AND FLANGES OF ITEMS PROJECTING THROUGH MEMBRANE. F.MAINTAIN ANY EXISTING ROOFING SYSTEM WARRANTIES. SECTION 07600 - FLASHING AND SHEET METAL A.GENERAL: PROVIDE FLASHING AND SHEET METAL, REGLETS, AND ACCESSORIES AS REQUIRED FOR ROOF REPAIRS AS REQUIRED FOR COMPLETE, WEATHERTIGHT INSTALLATION. B.STANDARDS: CONFORM TO SMACNA "ARCHITECTURAL SHEET METAL MANUAL" REQUIREMENTS FOR FLASHING AND SHEET METAL. C.DESIGN REQUIREMENTS: ALLOW FOR MOVEMENT OF COMPONENTS WITHOUT CAUSING BUCKLING, FAILURE OF JOINT SEALS, UNDUE STRESS ON FASTENERS OR OTHER DETRIMENTAL EFFECTS, WHEN SUBJECT TO 100 YEAR SEASONAL TEMPERATURE RANGES. D.SUBMITTALS: FURNISH PRODUCT DATA FOR MANUFACTURED PRODUCTS. E.WARRANTY: CORRECT FAILURE OF METAL FLASHING SYSTEM TO RESIST PENETRATION OF WATER AND DAMAGE FROM WIND; WARRANTY PERIOD TWO YEARS. F.FLASHING AND SHEET METAL: MATCH EXISTING, BUT NOT LESS THAN FOLLOWING: 1.GALVANIZED METAL FLASHING: ASTM A653/A653M GALVANIZED STEEL WITH MINIMUM 0.02 COPPER, AND WITH MINIMUM G90/Z275 GALVANIZED COATING; MINIMUM 24 GAGE. 2.PREFINISHED METAL FLASHING: 24 GAGE GALVANIZED STEEL WITH FACTORY FINISHED KYNAR 500 TYPE FLUOROPOLYMER COATING AND STRIPPABLE PROTECTIVE FILM; COLOR AS SELECTED FROM MANUFACTURER'S FULL RANGE OF COLORS. 3.ALUMINUM FLASHING: ASTM B209, ALLOY AS REQUIRED TO MATCH FINISH SPECIFIED FOR OTHER ALUMINUM COMPONENTS; THICKNESS MINIMUM 0.050" AT FLASHINGS. 4.STAINLESS STEEL SHEET METAL: ASTM A666, 2D ANNEALED FINISH, SOFT TEMPER EXCEPT WHERE HARDER TEMPER IS REQUIRED FOR FORMING OR PERFORMANCE; 0.015" (28 GAGE) TYPICAL. 5.COPPER SHEET METAL: ASTM B370, COLD ROLLED 16 OZ. (0.0216") THICK; SOFT TEMPER WHERE REQUIRED FOR FORMING. G.REGLETS: FRY/SPRINGLOK OR MM SYSTEMS/SNAP-TITE REGLETS; FABRICATE OF SAME METAL AS ADJACENT FLASHING AND SHEET METAL. H.METAL TO METAL SEALANT: BUTYL TYPE; NON-STAINING, NON-CORROSIVE, NON-SHRINKING, NON-SAGGING, ULTRA-VIOLET AND OZONE RESISTANT. I.INSTALLATION: COMPLY WITH SMACNA MANUAL. 1.INSTALL METAL FLASHING AND SHEET METAL IN ACCORDANCE WITH SMACNA ARCHITECTURAL SHEET METAL MANUAL; TIGHT IN PLACE, WITH CORNERS SQUARE, SURFACES TRUE AND STRAIGHT IN PLANES, AND LINES ACCURATE TO PROFILES AS INDICATED ON DRAWINGS. 2.INSTALL SEALANTS WHERE REQUIRED TO PREVENT DIRECT WEATHER PENETRATION. 3.COMPLETED INSTALLATION SHALL BE FREE OF RATTLES, NOISE DUE TO THERMAL AND AIR MOVEMENT, AND WIND WHISTLES. SECTION 07810 - PATCHING EXISTING FIREPROOFING A.GENERAL: PATCH EXISTING FIREPROOFING AS REQUIRED BY APPLICABLE CODES FOR CONSTRUCTION TYPE; NO ASBESTOS PERMITTED. B.DESIGN REQUIREMENTS: PROVIDE MATERIALS CAPABLE OF ATTAINING FIRE RATINGS AS REQUIRED FOR CONSTRUCTION TYPE. C.PERFORMANCE REQUIREMENTS: PROVIDE MATERIALS LISTED BY U.L. OR INDEPENDENT TESTING AND INSPECTION AGENCY ACCEPTABLE TO APPLICABLE AUTHORITIES. 1.FIRE RESISTANCE RATINGS: COMPLY WITH REQUIRED RATINGS BASED ON TESTS IN ACCORDANCE WITH ASTM E119. 2.SURFACE BURNING CHARACTERISTICS: MAXIMUM 25 FLAME SPREAD AND 25 SMOKE DENSITY WHEN TESTED IN ACCORDANCE WITH ASTM E84. D.CERTIFICATE: SUBMIT MANUFACTURER CERTIFICATION INDICATING APPLICATOR ACCEPTABILITY AND MATERIAL COMPLIANCE WITH APPLICABLE CODES AND CONTRACT DOCUMENTS. 1.CERTIFICATION SHALL INDICATE NEW MATERIALS USED TO PATCH EXISTING FIREPROOFED MEMBERS AT NEW AND EXISTING WORK ARE COMPATIBLE WITH EXISTING FIREPROOFING MATERIALS AND MEET ALL PERFORMANCE REQUIREMENTS. E.QUALIFICATION OF APPLICATOR: FIRM ACCEPTABLE TO MANUFACTURER OF FIREPROOFING MATERIALS, WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE ON PROJECTS OF SIMILAR SCOPE. F.MANUFACTURERS/PRODUCTS: MATCH EXISTING BUT NOT LESS THAN W.R. GRACE/MONOKOTE OR EQUAL. G.INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS AS REQUIRED TO PROVIDE REQUIRED FIRE RATINGS. 1.PROTECT ADJACENT SURFACES AND EQUIPMENT FROM DAMAGE BY OVERSPRAY, FALLOUT, AND DUSTING; MASK ADJACENT WORK AS REQUIRED. CLOSE OFF AND SEAL DUCT WORK IN AREAS WHERE FIREPROOFING IS BEING APPLIED. 2.CLEAN SUBSTRATE OF DIRT, DUST, GREASE, OIL, LOOSE MATERIAL, PAINTS, PRIMERS, AND OTHER MATTER WHICH AFFECTS BOND OF SPRAYED FIREPROOFING. 3.APPLY FIREPROOFING IN SUFFICIENT THICKNESS AND DENSITY TO ACHIEVE REQUIRED FIRE RATINGS. 4.APPLY FIREPROOFING OVER SUBSTRATE, BUILDING TO REQUIRED THICKNESS WITH AS MANY PASSES OR STAGES NECESSARY TO COVER WITH MONOLITHIC BLANKET OF UNIFORM DENSITY AND TEXTURE. SECTION 07840 - FIRESTOPPING A.GENERAL: PROVIDE PENETRATION-TYPE FIRESTOPPING FOR TIME-RATED FLOOR, WALL, AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE AND HOT GASES. B.CODES: CONFORM TO APPLICABLE CODE REQUIREMENTS FOR BOTH F AND T RATINGS. C.STANDARDS: PASS ASTM E814 THROUGH-PENETRATION FIRE STOPS, ASTM E119 FIRE TESTS AND ASTM E84 FLAME SPREAD/SMOKE CONTRIBUTION MAXIMUM 25/25. D.MANUFACTURERS: 3M/FIRE BARRIER, HILTI/FIRESTOP SYSTEMS, OR APPROVED EQUAL. E.GENERAL: CHOOSE PRODUCTS AND METHODS MEETING APPLICABLE CODES AND SPECIFICATION REQUIREMENTS FOR EACH FIRESTOPPING APPLICATION, SUBJECT TO ARCHITECT'S ACCEPTANCE. F.FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME-RATED FLOOR, WALL, AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE, AND HOT GASES. 1.PENETRATION TEST: FURNISH MATERIALS PASSING ASTM E814 FOR PENETRATION FIRE STOPPING INDICATING MAINTENANCE OF TIME-RATED ADJACENT ASSEMBLIES. 2.FIRESTOPPING: MAINTAIN FIRE RATING OF ASSEMBLY IN WHICH FIRESTOPPING IS INSTALLED, SUCH AS FLOOR, PARTITION, OR WALL, IN ACCORDANCE WITH ASTM E119 TESTS. G.INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST RESULTS AS REQUIRED TO PROVIDE REQUIRED FIRE RATINGS. 1.FIELD INSPECTIONS: MAINTAIN COPY OF MANUFACTURER'S INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS AT EACH WORK AREA. SECTION 07900 - JOINT SEALERS A.GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDED ELSEWHERE; TYPE SUITABLE FOR APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. B.INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM FIVE YEAR'S SUCCESSFUL EXPERIENCE ON PROJECTS OF SIMILAR TYPE AND SIZE, USING SPECIFIED PRODUCTS. C.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EXPOSED JOINT SEALERS IN REQUIRED COLORS. D.WARRANTY: REPAIR OR REPLACE JOINT SEALERS WHICH FAIL TO PERFORM AS INTENDED, BECAUSE OF LEAKING, CRUMBLING, HARDENING, SHRINKAGE, BLEEDING, SAGGING, STAINING AND LOSS OF ADHESION; WARRANTY PERIOD TWO YEARS. E.EXTERIOR NON-TRAFFIC JOINTS: GE/SILPRUF, DOW/790-795, OR PECORA/854, LOW MODULUS SILICONE SEALANT. F.TRAFFIC BEARING JOINTS: MAMECO/VULKEM 245, OR PECORA/NR-200 UREXPAN, MULTI-COMPONENT POLYURETHANE, SELF-LEVELING JOINT SEALER. G.MILDEW-RESISTANT SANITARY SEALANTS: GE/SANITARY SEALANT, DOW/BATHTUB CAULK, OR PECORA/863 #345 WHITE; PROVIDE AT INTERIOR AREAS WHERE SEALANT WILL BE EXPOSED TO WATER. H.GENERAL INTERIOR JOINT SEALER: PECORA/AC-20 OR SONNEBORN/SONOLAC, ACRYLIC OR LATEX EMULSION. I.MISCELLANEOUS MATERIALS: PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE, AND SEALANT BACKER RODS AS RECOMMENDED BY SEALANT MANUFACTURER FOR APPLICATIONS INDICATED. 1.OVERSIZE BACKER ROD MINIMUM 30 % TO 50 % OF JOINT OPENING. J.COLORS: AS INDICATED OR AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE OF COLORS. K.PREPARATION: CLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT SEALER, AND PRIME OR SEAL JOINT SURFACES AS RECOMMENDED BY MANUFACTURER. L.INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND ASTM C1193. 1.EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE DEPOSITED IN UNIFORM, CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS, WITH COMPLETE "WETTING" OF BOND SURFACES. DIVISION EIGHT: DOOR AND WINDOWS SECTION 08110 - STEEL DOORS AND FRAMES A.GENERAL: PROVIDE STEEL DOORS AND FRAMES AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION; COORDINATE WITH SECTION 08700 - HARDWARE. B.STANDARDS: COMPLY WITH NAAMM HMMA 840 'GUIDE SPECIFICATIONS FOR INSTALLATION AND STORAGE OF HOLLOW METAL DOORS' AND ANSI A250.8 - SDI-100 'RECOMMENDED SPECIFICATIONS FOR STANDARD STEEL DOORS AND FRAMES'. 1.FIRE RATED STANDARDS: FURNISH MATERIALS TESTED, LABELED AND INSPECTED BY U.L., WARNOCK HERSEY, OR TESTING AGENCY ACCEPTABLE TO APPLICABLE AUTHORITIES. C.SUBMITTALS: SUBMIT PRODUCT DATA. D.MANUFACTURERS: AMWELD, CECO, OR STEELCRAFT. E.HOLLOW METAL DOORS: FLUSH HOLLOW METAL DOORS FULL FLUSH TYPE; ANSI A250.8, LEVEL A, CLOSE TOP AT EXTERIOR DOORS. 1.CORE: PROVIDE STEEL STIFFENED CORE; INSULATED AT EXTERIOR DOORS. 2.GAGE: PROVIDE MINIMUM 18 GAGE AT INTERIOR DOORS, MINIMUM 16 GAGE AT EXTERIOR DOORS. F.STEEL (HOLLOW METAL) FRAMES: MINIMUM 18 GAGE FULLY WELDED FRAMES AT INTERIOR DOORS, MINIMUM 16 GAGE FULLY WELDED FRAMES AT EXTERIOR DOORS. G.FIRE RATED UNITS: CONFORM TO NFPA 80; PROVIDE U.L. OR WARNOCK HERSEY LABELED DOORS AND FRAMES AS REQUIRED. H.ACCESSORIES: PROVIDE DOOR SILENCERS, ANCHORS, AND ACCESSORIES. I.FABRICATION: CONFORM TO REQUIREMENTS OF NAAMM HMMA 840. 1.DOOR SILENCERS: PLACE MINIMUM THREE SINGLE BUMPERS ON SINGLE DOOR FRAMES; SPACE EQUALLY ALONG STRIKE JAMBS; PLACE TWO SINGLE BUMPERS ON DOUBLE DOOR FRAME HEADS. J.FINISH: PRIME PAINT INTERIOR UNITS, GALVANIZE AND PRIME PAINT EXTERIOR UNITS; MINIMUM A60 GALVANIZING; CLEAN, DEGREASE AND FACTORY PRIME PAINT. K.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND NAAMM HMMA 840 STANDARDS. 1.INSTALL FIRE RATED UNITS IN CONFORMANCE WITH FIRE LABEL REQUIREMENTS & NFPA80. 2.INSTALL DOORS AND FRAMES PLUMB AND SQUARE, AND WITH MAXIMUM DIAGONAL DISTORTION OF 1/16". SECTION 08200 - WOOD DOORS AND FRAMES A.GENERAL: PROVIDE WOOD DOORS AND FRAMES AND ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION. COORDINATE WITH SECTION 08110 (STEEL DOORS AND FRAMES), SECTION 08120 (ALUMINUM DOORS AND FRAMES), AND SECTION 08700 (HARDWARE). B.STANDARDS: COMPLY WITH AWI/AWMAC (QSI) 'ARCHITECTURAL WOODWORK QUALITY STANDARDS ILLUSTRATED'. C.SUBMITTALS: SUBMIT PRODUCT DATA, SHOP DRAWINGS, AND FINISH SAMPLES. D.MANUFACTURER'S QUALIFICATIONS: COMPANY SPECIALIZING IN THE MANUFACTURE OF THE PRODUCTS SPECIFIED IN THIS SECTION WITH A MINIMUM FIVE YEARS EXPERIENCE. E.PACKAGE, DELIVER AND STORE DOORS IN ACCORDANCE WITH SPECIFIED QUALITY STANDARD. INSPECT FOR DAMAGE. F.MANUFACTURERS: GRAHAM WOOD DOORS, EGGERS INDUSTRIES, MARSHFIELD DOOR SYSTEMS OR APPROVED EQUAL. G.PREMIUM GRADE HEAVY DUTY PERFORMANCE IN ACCORDANCE WITH AWI/AWMAC STANDARDS, 5 PLY WOOD VENEER FACED SOLID CORE DOORS, 1 34 INCH THICK, FLUSH CONSTRUCTION. 1.WOOD VENEER SPECIES AND CUT AS INDICATED ON DRAWINGS. 2.FACTORY PREFINISHED WITH A CUSTOM COLOR TRANSPARENT FINISH. H.FABRICATE DOORS IN ACCORDANCE WITH DOOR QUALITY STANDARD NOTED. CORES CONSTRUCTED WITH STILES AND RAILS, PROVIDE SOLID BLOCKS AT LOCK/HARDWARE EDGE AND AT TOP AND BOTTOM OF DOORS. FACTORY MACHINE DOORS FOR HARDWARE OTHER THAN SURFACE MOUNTED HARDWARE. I.FACTORY FIT DOORS FOR FRAME OPENING DIMENSIONS IDENTIFIED ON SHOP DRAWINGS, WITH EDGE CLEARANCES IN ACCORDANCE WITH SPECIFIED QUALITY STANDARD. J.INSTALL DOORS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND SPECIFIED QUALITY STANDARD. DO NOT INSTALL DOORS IN FRAME OPENINGS THAT ARE NOT PLUMB OR ARE OUT OF TOLERANCE FOR SIZE OR ALIGNMENT. K.DO NOT FIELD CUT OR TRIM - IF FIT OR CLEARANCE IS NOT CORRECT, REPLACE DOOR. L.ADJUST DOORS FOR SMOOTH AND BALANCED DOOR MOVEMENT, ADJUST CLOSERS FOR FULL CLOSURE. SECTION 08310 - ACCESS DOORS AND PANELS A.GENERAL: PROVIDE ACCESS DOORS AS REQUIRED FOR ACCESS TO VALVES AND CONTROLS LOCATED BEHIND FINISHED WALLS AND CEILINGS NOT OTHERWISE ACCESSIBLE, WITH ACCESSORIES FOR COMPLETE INSTALLATION. 1.COORDINATE WITH VARIOUS TRADES FOR CONTROLS AND VALVES WHICH MAY BE CONCEALED. B.SUBMITTALS: FURNISH PRODUCT DATA FOR EACH TYPE OF ACCESS DOOR AND PANEL. C.MANUFACTURERS: MILCOR, J.L INDUSTRIES, OR KARP. D.TYPE: FLUSH TYPE AT NON FIRE RATED CONSTRUCTION, STANDARD U.L. APPROVED FRAMED TYPE AT FIRE RATED CONSTRUCTION; KEY OPERATED. 1.FRAMES: FABRICATE FROM MINIMUM 16 GAGE. 2.DOORS: FLUSH PANEL TYPE, FABRICATE FROM MINIMUM 14 GAGE STEEL. 3.HINGE: PROVIDE CONTINUOUS PIANO TYPE HINGE. 4.FINISH: FINISH WITH MANUFACTURER'S FACTORY-APPLIED ENAMEL PRIME COAT APPLIED OVER PHOSPHATE COATING ON STEEL. E.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE REQUIREMENTS FOR FIRE RATINGS. 1.SET FRAMES ACCURATELY IN POSITION AND SECURELY ATTACH TO SUPPORTS WITH FACE PANELS PLUMB OR LEVEL IN RELATION TO ADJACENT FINISH SURFACES. 2.ADJUST HARDWARE AND DOORS AFTER INSTALLATION FOR PROPER OPERATION. 3.REMOVE AND REPLACE DOORS OR FRAMES WHICH ARE WARPED, BOWED OR OTHERWISE DAMAGED. SECTION 08411 - ALUMINUM FRAMED ENTRANCES & STOREFRONTS A.GENERAL: PROVIDE AND FURNISH ALL NECESSARY MATERIALS, LABOR, AND EQUIPMENT FOR THE COMPLETE INSTALLATION OF THE ALUMINUM STOREFRONT SYSTEM AS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN. SECTION INCLUDES MANUFACTURER APPROVED SEALANTS, GLASS, AND GLAZINGS: 1.ALUMINUM SWING DOORS 2.ALUMINUM STOREFRONT SYSTEMS B.SYSTEM PERFORMANCE: PERFORMANCE REQUIREMENTS MEETING REQUIREMENTS INDICATED AND SOUTH FLORIDA BUILDING PROTOCOLS TAS 201, TAS 202, AND TAS 203 AND COMPLY WITH THE FOLLOWING PERFORMANCE REQUIREMENTS. 1.AIR INFILTRATION: AIR INFILTRATION SHALL BE TESTED IN ACCORDANCE WITH ASTM E 283. RESULTS TO COMPLY WITH MANUFACTURER'S TESTED MAXIMUMS. 2.WATER INFILTRATION: NO UNCONTROLLED WATER OTHER THAN CONDENSATION ON INDOOR FACE OF ANY COMPONENT TESTED IN ACCORDANCE WITH ASTM E 331. RESULTS TO COMPLY WITH MANUFACTURER'S TESTED DIFFERENTIALS. 3.WIND LOADS: COMPLETED STOREFRONT SYSTEM SHALL WITHSTAND WIND PRESSURE LOADS NORMAL TO WALL PLANE INDICATED PER MANUFACTURER'S REQUIREMENTS. 4.DEFLECTION: MAXIMUM ALLOWABLE DEFLECTION IN ANY MEMBER WHEN TESTED SHALL BE IN ACCORDANCE WITH ASTM E 330 WITH ALLOWABLE STRESS IN ACCORDANCE WITH AAMA SPECIFICATIONS FOR ALUMINUM STRUCTURES. 5.FORCED ENTRY RESISTANCE: TESTS PERFORMED SIMULTANEOUSLY WITH 300 LB. FORCES APPLIED TO THE ACTIVE DOOR PANEL WITHIN 3" OF THE LOCKS IN THE DIRECTION THAT WOULD TEND TO OPEN THE DOOR WHILE 150 LB. FORCES ARE APPLIED IN BOTH PERPENDICULAR DIRECTIONS TO THE 300 LB. FORCE SIMULTANEOUSLY. 6.THERMAL PERFORMANCE: WHEN TESTED IN ACCORDANCE WITH AAMA 1503 AND NFRC 102, CONDENSATION RESISTANCE FACTOR TO BE A MINIMUM OF 28 AND THERMAL TRANSMITTANCE U VALUE TO BE 0.77 BTU/HR/FT/FARENHEIGHT OR LESS. 7.THERMAL MOVEMENT: PROVIDE FOR THERMAL MOVEMENT CAUSED BY 180 DEGREES F SURFACE TEMPERATURE, WITHOUT CAUSING BUCKLING STRESSES ON GLASS, JOINT SEAL FAILURE, UNDUE STRESS ON STRUCTURAL ELEMENTS, DAMAGING LOADS ON FASTENERS, REDUCTION OF PERFORMANCE, OR DETRIMENTAL EFFECTS. C.SUBMITTALS: FURNISH PRODUCT DATA FOR EACH TYPE OF ALUMINUM DOOR & STOREFRONT SYSTEM. D.MANUFACTURERS: YKK AP AMERICA, INC. E.WARRANTY: SUBMIT FOR OWNER'S ACCEPTANCE, MANUFACTURER'S STANDARD WARRANTY DOCUMENT EXECUTED BY AN AUTHORIZED COMPANY OFFICIAL. A MANUFACTURER'S WARRANTY PRIOR OF ONE YEAR STANDARD COMMENCING ON THE DATE OF SUBSTANTIAL COMPLETION FOR THE PROJECT PROVIDED THAT THE WARRANTY, IN NO EVENT, SHALL START LATER THAN SIX MONTHS FROM THE DATE OF SHIPMENT BY YKK AP AMERICA, INC. F.MATERIALS: PROVIDE FINISHES AS SPECIFIED WITHIN THE CONSTRUCTION DOCUMENTS. SYSTEM TO INCLUDE ANY MANUFACTURER STANDARD ACCESSORIES/HARDWARE/SEALANTS/FASTENERS IN FINISHES/COLORS COORDINATING WITH FINISH AS SPECIFIED. G.EXECUTION: COMPLY WITH MANUFACTURER'S PRODUCT DATA, INCLUDING PRODUCT TECHNICAL BULLETINS, INSTALLATION INSTRUCTIONS, AND PRODUCT CARTON INSTRUCTIONS. THE LATEST INSTALLATION INSTRUCTIONS ARE AVAILABLE AT WWW.YKKAP.COM. 1.PROTECT ADJACENT WORK AREAS AND FINISH SURFACES FROM DAMAGE DURING PRODUCT INSTALLATION. 2.INSTALL MANUFACTURER'S SYSTEM IN ACCORDANCE WITH SHOP DRAWINGS, AND WITHIN SPECIFIED TOLERANCES. SHIM AND BRACE ALUMINUM SYSTEM BEFORE ANCHORING TO STRUCTURE. PROVIDE ALL NECESSARY FLASHING AND WEEPS TO EXTERIOR. 3.ADJUST SWING DOORS FOR OPERATION IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 4.THE GENERAL CONTRACTOR SHALL CLEAN INSTALLED PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTION PRIOR TO OWNER'S ACCEPTANCE, AND REMOVE CONSTRUCTION DEBRIS FROM PROJECT SITE. SECTION 08620 - UNIT SKYLIGHTS A.GENERAL: PROVIDE UNIT SKYLIGHTS CAPABLE OF WITHSTANDING LOADS INDICATED WITHOUT FAILURE, WITH ACCESSORIES FOR COMPLETE INSTALLATION. UNIT SKYLIGHTS TO MEET THE REQUIREMENTS OF THE AMERICAN ARCHITECTURAL MANUFACTURER'S ASSOCIATION (AAMA) PUBLICATION "VOLUNTARY UNIFORM LOAD STRUCTURAL STANDARD FOR PLASTIC DOMED SKYLIGHTS" (AAMA 1606-82) WHICH REQUIRES ACRYLIC THICKNESS ADEQUATE TO WITHSTAND A POSITIVE AND NEGATIVE TEST PRESSURE OF 60 PSF. A FAILURE INCLUDES: 1.THERMAL STRESSES TRANSFERRED TO THE BUILDING STRUCTURE. 2.FRAMING MEMBERS TRANSFERRING STRESSES, INCLUDING THOSE CAUSED BY THERMAL AND STRUCTURAL MOVEMENT, TO GLAZING. 3.NOISE OR VIBRATION CAUSED BY THERMAL AND STRUCTURAL MOVEMENT AND WIND. 4.WEAKENING OF FASTENERS, ATTACHMENTS, AND OTHER COMPONENTS. B.SUBMITTALS: FOR EACH TYPE OF SKYLIGHT SPECIFIED, INCLUDE DETAILS OF CONSTRUCTION AND INSTALLATION RELATIVE TO APPLICABLE ROOFING MATERIALS. INCLUDE MANUFACTURER'S COLOR CHARTS SHOWING A FULL RANGE OF COLORS AVAILABLE FOR EACH TYPE OF SKYLIGHT GLAZING AND ALUMINUM FINISH FOR SELECTION. C.MANUFACTURERS: WASCO PRODUCTS, INC. OR APPROVED EQUAL. D.QUALITY ASSURANCE: PROVIDE THERMOFORMED DOME (OUTER) FABRICATION FROM SHEET IDENTICAL TO THOSE TESTED FOR THE FOLLOWING FIRE-TEST RESPONSE CHARACTERISTICS, PER ASTM TEST OR BY UL OR OTHER TESTING AND INSPECTING AGENCIES ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. IDENTIFY PLASTIC SHEETS WITH APPROPRIATE MARKINGS OF APPLICABLE TESTING AND INSPECTING ORGANIZATION. 1.SELF-IGNITION TEMP: ACRYLIC AND IMPACT MODIFIED ACRYLIC 750 DEGREES PER ASTM D 1929. 2.SMOKE DENSITY RATING: ACRYLIC 13.5% OR LESS PER ASTM D 2843, IMPACT MODIFIED ACRYLIC 3.8% AT 6.0 mm OR LESS PER ASTM D 2843-99. 3.RELATIVE BURNING CHARACTERISTICS: TEST PER ASTM D 635 PROVIDE MULTI-WALL CELLULAR POLYCARBONATE PANEL (INNER HORIZONTAL PANEL) FABRICATED FROM AN APPROVED CELLULAR POLYCARBONATE GLAZING (LIGHT TRANSMITTING) MATERIAL IDENTICAL TO THAT TESTED WITH A CC1 FIRE RATING CLASSIFICATION PER ASTM D-635 AND FILLED WITH NANOGEL INSULATION. E.WARRANTY: PROVIDE WRITTEN WARRANTY SIGNED BY MANUFACTURER, AGREEING TO REPAIR OR REPLACE WORK THAT EXHIBITS DEFECTS IN MATERIALS OR WORKMANSHIP AND GUARANTEEING WEATHER-TIGHT AND LEAK FREE PERFORMANCE. "DEFECTS" IS DEFINED AS UNCONTROLLED LEAKAGE OF WATER AND ABNORMAL AGING OR DETERIORATION. WARRANTY PERIOD OF 5 YEARS FROM SUBSTANTIAL COMPLETION ON THE SKYLIGHT, PLASTIC/ ACRYLIC. A WARRANTY OF 1 YEAR FROM DATE OF SUBSTANTIAL COMPLETION FOR FILM INTEGRITY ON ANODIZED FINISH AND FOR BAKED ENAMEL FINISH. F.MATERIALS: 1.CURB FRAME: BRIGHT WHITE HIGH PERFORMANCE PVC WITH BRONZE CAP STOCK AND MINIMUM EFFECTIVE THICKNESS OF 0.060 INCH (1.5MM). PROVIDE INTEGRAL CONDENSATION GUTTER SYSTEM WITH CORNERS FULLY WELDED FOR WATERPROOF QUALITY. 2.RETAINER FRAME: EXTRUDED ALUMINUM ALLOW 6064-T5 MIN. ASTM B-221 (ASTM B-221 M) WITH MINIMUM EFFECTIVE THICKNESS OF 0.060 INCH (1.5MM). CURBS TO BE MIN. 1 1/2" WIDE FIELD BUILT OR PRE-FABRICATED BY OTHERS. 3.PLASTIC SHEETS: MONOLITHIC, FORMABLE, TRANSPARENT (COLORLESS - CLEAR) WITH GOOD WEATHER AND IMPACT RESISTANT. ACRYLIC TO BE ASTM D-4802, THERMOFORMABLE, ACRYLIC (METHACRYLATE), CATEGORY C-2 OR CC-2 TYPE UVA (FORMULATED WITH ULTRAVIOLET ABSORBER), WITH FINISH 1 (SMOOTH OR POLISHED), UNLESS OTHERWISE INDICATED. AVERAGE IMPACT STRENGTH OF 5.0 FT-LB/IN WHEN TESTED PER ASTM D-256 (CHARPY UNNOTCHED). IMPACT MODIFIED ACRYLIC TO BE ASTM D-4802, THERMOFORMABLE, ACRYLIC (METHACRYLATE) IMPACT MODIFIED SHEETS MANUFACTURED BY THE EXTRUSION PROCESS, CATEGORY C-2 OR CC-2, TYPE UVA (FORMULATED WITH ULTRAVIOLET ABSORBER) WITH FINISH 1 (SMOOTH OR POLISHED). AVERAGE IMPACT STRENGTH OF 0.75 FT-LB/INCH (40 J/M OF NOTCH) WHEN TESTED ACCORDING TO ASTM D-256, TEST METHOD A (IZOD). 4.THERMAL BREAK: FABRICATE SKYLIGHT UNITS WITH THERMAL BARRIER SEPARATING INTERIOR METAL FRAMING FROM MATERIALS EXPOSED TO OUTSIDE TEMPERATURE. 5.SHAPE & SIZE: AS INDICATED BY MODEL NUMBER. 6.GLAZING: OUTER DOME THERMOFORMED ACRYLIC (CLEAR) OR IMPACT MODIFIED ACRYLIC (CLEAR) WITH 25% RISE. INNER (HORIZ.) MULTI-WALL TRANSLUCENT CELLULAR POLYCARBONATE PANEL FILLED WITH NANOGEL INSULATION. 7.FASTENERS: SAME METAL AS METALS BEING FASTENED, OR NONMAGNETIC STAINLESS STEEL OR OTHER NON-CORROSIVE METAL AS RECOMMENDED BY MANUFACTURER. 8.BITUMINOUS COATING: SSPC-PAINT 12, SOLVENT-TYPE, BITUMINOUS MASTIC, NOMINALLY FREE OF SULFER AND CONTAINING NO ASBESTOS FIBERS, COMPOUNDED FOR 15-MIL (0.4MM) DRY FILM THICKNESS PER COATING. 9.ALUMINUM FINISH: CLASS 1, CLEAR ANODIZED FINISH. G.PLASTIC SKYLIGHT UNITS: FACTORY ASSEMBLED, CURB MOUNTED UNIT CONSISTING OF PLASTIC GLAZING, GASKETING, INNER FRAME DESIGNED TO MOUNT ON SEPARATE CURB. PROVIDE MODEL AS SPECIFIED IN THE DRAWINGS TO MEET THE REQUIREMENTS OF THIS SPECIFICATION. H.INSTALLATION: COMPLY WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR PROTECTING, HANDLING, AND INSTALLING SKYLIGHT COMPONENTS. COORDINATE WITH EXISTING ROOF DECK, VAPOR BARRIERS, ROOF INSULATION, AND FLASHING AS TO ASSURE THAT EACH ELEMENT OF THE WORK PERFORMS PROPERLY AND THAT THE COMBINED ELEMENTS ARE WATERPROOF AND WEATHER-TIGHT. ANCHOR UNITS SECURELY TO SUPPORTING STRUCTURAL SUBSTRATES, ADEQUATE TO WITHSTAND LATERAL AND THERMAL STRESSES AS WELL AS INWARD AND OUTWARD LOADING PRESSURES. WHERE COUNTER FLASHING IS REQUIRED AS A COMPONENT OF THE SKYLIGHT, INSTALL TO PROVIDE AN ADEQUATE WATERPROOF OVERLAP WITH ROOFING OR ROOF FLASHING (AS COUNTER FLASHING). SEAL WITH THICK BEAD OF MASTIC SEALANT, EXCEPT WHERE OVERLAP IS INDICATED TO BE LEFT OPEN FOR VENTILATION. I.CLEANING & PROTECTION: CLEAN EXPOSED METAL AND PLASTIC SURFACES ACCORDING TO MANUFACTURER'S INSTRUCTIONS. TOUCH-UP DAMAGED METAL COATINGS. CLEAN PLASTIC SKYLIGHT UNITS, INSIDE AND OUT, NOT MORE THAN 5 DAYS PRIOR TO DATE OF SUBSTANTIAL COMPLETION. SECTION 08700 - HARDWARE A.GENERAL: PROVIDE DOOR HARDWARE FOR HOLLOW METAL DOORS, WOOD DOORS, AND ALUMINUM/GLASS DOORS AND PROVIDE CYLINDERS FOR DOORS PROVIDED WITH HARDWARE, WITH ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL DOOR INSTALLATIONS. B.STANDARDS: COMPLY WITH BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA) ANSI/BHMA 156 SERIES STANDARDS, ANSI/ICC A117.1 (AMERICAN NATIONAL STANDARD FOR ACCESSIBLE AND USEABLE BUILDINGS AND FACILITIES), DHI (DOOR HARDWARE INSTITUTE). C.CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS WITH DISABILITIES. 1.FIRE RATED DOORS: COMPLY WITH REQUIREMENTS OF NFPA 80 AND APPLICABLE CODES FOR FIRE RATED DOOR HARDWARE; PROVIDE HARDWARE BEARING UNDERWRITERS LABORATORY (UL) LABELS. D.SUBMITTALS: FURNISH SHOP DRAWINGS, PRODUCT DATA INCLUDING KEYING SCHEDULE, AND SAMPLES OF EACH REQUIRED STYLE AND FINISH. 1.SUPPLY TEMPLATES TO DOOR AND FRAME MANUFACTURERS FOR PROPER AND ACCURATE SIZING AND LOCATIONS OF CUT-OUTS FOR HARDWARE. E.GENERAL MATERIALS: PROVIDE COMPLETE HARDWARE WITH ACCESSORIES AS REQUIRED FOR DOORS AND APPLICATIONS INDICATED AND NOT PROVIDED UNDER OTHER SECTIONS. F.HINGES: HAGER OR EQUAL; FULL MORTISED BUTT HINGES; SIZE AND NUMBER AS RECOMMENDED BY MANUFACTURER; NONREMOVABLE PINS AT EXTERIOR OUTSWINGING DOORS, BALL-BEARING HINGES AT FIRE RATED DOORS AND DOORS WITH CLOSERS. G.LOCKSETS/LATCHSETS: SCHLAGE, ADAMS RITE; AS INDICATED ON THE DRAWINGS, SOLID LEVER TYPE WITH ROSE; KEYING AS DIRECTED BY TENANT; PROVIDE CYLINDERS FOR DOORS FURNISHED WITH LOCKS. H.OVERHEAD CLOSERS: HAGER 5200 SERIES OR EQUAL, FULLY ADJUSTABLE; MODERN TYPE WITH COVER. I.ACCESSORIES: PROVIDE DOOR STOPS, THRESHOLDS, WEATHERSTRIPPING, TRIM, COORDINATORS AND ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL DOOR INSTALLATION. 1.THRESHOLDS, STOPS, TRIM, AND MISCELLANEOUS HARDWARE: PROVIDE AS INDICATED, AS SPECIFIED, AS INCLUDED IN HARDWARE SCHEDULE, AND AS REQUIRED FOR COMPLETE INSTALLATION. 2.WEATHERSTRIPPING: PROVIDE CONTINUOUS WEATHERSTRIPPING AT TOP AND SIDES OF EXTERIOR DOORS. 3.FIRE RATED GASKETS: PROVIDE CONTINUOUS FIRE RATED GASKETS AT TOP AND SIDES OF FIRE RATED DOORS. 4.THROUGH BOLTS: THROUGH BOLTS AND GROMMET NUTS SHALL BE AVOIDED ON DOOR FACES IN HIGHLY VISIBLE AREAS, UNLESS NO ALTERNATIVE IS POSSIBLE, AS DIRECTED AND APPROVED, AND SHALL NOT BE USED FOR SOLID WOOD CORE DOORS. J.FINISH: BHMA 626 (US26D), SATIN FINISHED CHROMIUM PLATED UNLESS OTHERWISE INDICATED. K.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPLICABLE REQUIREMENTS FOR ACCESS AND FOR FIRE RATINGS. 1.FIT HARDWARE PRIOR TO PAINTING, THEN REMOVE FOR PAINTING/FINISHING OF DOORS AND FRAMES BEFORE FINAL INSTALLATION OF HARDWARE. 2.HEIGHTS TO COMPLY WITH APPLICABLE CODES AND BHMA RECOMMENDATIONS. 3.ADJUST HARDWARE FOR SMOOTH OPERATION. 4.HARDWARE GROUPS: REFER TO DRAWINGS. SECTION 08810 - GLAZING A.GENERAL: PROVIDE GLAZING AND GLAZING ACCESSORIES FOR DOORS, FRAMES, SIDELIGHTS, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION AS INDICATED ON THE DRAWINGS. B.STANDARDS: ASTM C1036 (STANDARD SPECIFICATION FOR FLAT GLASS), ASTM C1048 (STANDARD SPECIFICATION FOR HEAT TREATED FLAT GLASS), AND ASTM E2190 (STANDARD SPECIFICATION FOR INSULATING GLASS UNIT PERFORMANCE ADN EVALUATION). C.PERFORM WORK IN ACCORDANCE WITH GANA GLAZING MANUAL AND FGMA SEALANT MANUAL FOR GLAZING INSTALLATION METHODS. DO NO INSTALL GLAZING WHEN AMBIENT TEMPERATURE IS LESS THAN 50 DEGREES F. D.PROVIDE A 5 YEAR WARRANTY ON SEALED INSULATING GLASS UNITS TO INCLUDE COVERAGE FOR SEAL FAILURE, INTERPANE DUSTING OR MISTING, INCLUDING REPLACEMENT OF FAILED UNITS. PROVIDE A 5 YEAR WARRANTY OF LAMINATED GLASS TO INCLUDE COVERAGE FOR DELAMINATION, INCLUDING REPLACEMENT OF FAILED UNITS. E.GLAZING TYPES: AS INDICATED ON THE DRAWINGS. F.FLOAT GLASS: 1.ANNEALED TYPE:ASTM C1036, TYPE 1, TRANSPARENT FLAT, CLASS 1 CLEAR, QUALITY Q3. 2.HEAT STRENGTHEN AND FULLY TEMPERED TYPE: ASTM C1048 3.LAMINATED GLASS: ASTM C1172 G.SEALED/INSULATING GLASS UNITS: CERTIFIED BY AN INDEPENDENT TESTING AGENCY TO COMPLY WITH ASTM E2190. ALUMINUM, BENT AND SOLID CORNER EDGE SPACERS. GLASS TO ELASTOMER WITH SUPPLEMENTARY SILICONE SEALANT EDGE SEAL - PURGE INNER SPACE WITH DRY HERMETIC AIR. H.GLAZING COMPOUNDS: 1.BUTYL SEALANT - SINGLE COMPONENT, SHORE A HARDNESS OF 10 TO 20, BLACK COLOR, NON-SKINNING. 2.SILICONE SEALANT - SINGLE COMPONENT, CHEMICAL CURING, CAPABLE OF WATER IMMERSION WITHOUT LOSS OF PROPERTIES, NON-BLEEDING, NON-STAINING, ASTM C920, TYPE S, GRADE NS, CLASS 25, CURED SHORE HARDNESS OF 15 TO 25. COLOR AS SELECTED FROM MANUFACTURER'S STANDARD COLORS. I.GLAZING ACCESSORIES: SETTING BLOCKS, SPACER SHIMS, GLAZING TAPE, GLAZING GASKETS, GLAZING CLIPS, ETC. AS REQUIRED FOR A COMPLETE INSTALLATION. J.VERIFY THAT OPENINGS FOR GLAZING ARE CORRECTLY SIZED AND WITHIN TOLERANCE. VERIFY THAT GLAZING CHANNELS OR RECESSES ARE CLEAN, FREE OF OBSTRUCTIONS THAT MAY IMPEDE MOISTURE MOVEMENT, AND ARE READY TO RECEIVE GLAZING. K.INSTALL GLAZING BY METHOD RECOMMENDED BY GLAZING AND FRAME MANUFACTURER PER ALL MANUFACTURER INSTRUCTIONS. L.INSTALL SEALANTS IN ACCORDANCE WITH ASTM C1193 AND FGMA SEALANT MANUAL. INSTALL SEALANTS IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. DIVISION NINE: FINISHES SECTION 09260 - GYPSUM BOARD ASSEMBLIES (WALLS AND CEILINGS) A.GENERAL: PROVIDE GYPSUM BOARD SYSTEMS INCLUDING METAL FRAMING ACCESSORIES, GYPSUM BOARD, JOINT TREATMENT, ACOUSTICAL INSULATION, ACOUSTICAL SEALANT, AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. B.STANDARDS: COMPLY WITH ASTM C754, ASTM C840, AND REQUIREMENTS FOR FIRE RATINGS. 1.DEFLECTIONS: MAXIMUM L/240 TYP., L/360 AT LOCATIONS INDICATED TO RECEIVE TILE. C.FIRE-RATED ASSEMBLIES: LISTED BY UNDERWRITER'S LABORATORY, GYPSUM ASSOCIATION (GA) FILE NO'S IN GA-600 FIRE RESISTANCE DESIGN MANUAL, OR OTHER LISTING APPROVED BY APPLICABLE AUTHORITIES. D.SYSTEMS RESPONSIBILITY: PROVIDE PRODUCTS MANUFACTURED BY OR RECOMMENDED BY MANUFACTURER OF GYPSUM BOARD TO MAINTAIN SINGLE-SOURCE RESPONSIBILITY FOR SYSTEM. E.SUBMITTALS: FURNISH PRODUCT DATA. F.MANUFACTURERS: USG, GEORGIA PACIFIC, OR NATIONAL GYPSUM. G.METAL FRAMING: CONFORM TO ASTM C754; COMPLETE 16 GAGE CEILING FRAMING AND MIN. 22 GAGE STUDS WALL FRAMING FOR GYPSUM BOARD SYSTEMS; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 1.MANUFACTURED SUSPENSION SYSTEM SUCH AS CHICAGO METALLIC/DRYWALL SYSTEM IS ACCEPTABLE. H.GYPSUM BOARD: CONFORM TO ASTM C840; U.L. LISTED FIRE RESISTANT GYPSUM BOARD. 1.STANDARD: ASTM C1396, 5/8" THICK. 2.CORE BOARD: ASTM C1396, 1" THICK. I.GYPSUM BOARD ACCESSORIES: COMPLY WITH ASTM C840. 1.PROVIDE PROTECTIVE COATED STEEL CORNER BEADS AND EDGE TRIM; TYPE DESIGNED TO BE CONCEALED IN FINISHED CONSTRUCTION BY TAPE AND JOINT COMPOUND. 2.CORNER BEADS: MANUFACTURER'S STANDARD METAL BEADS. 3.REINFORCING TAPE, JOINT COMPOUND, ADHESIVE, WATER, FASTENERS: TYPES RECOMMENDED BY SYSTEM MANUFACTURER AND CONFORMING WITH ASTM C475. J.FIRE RATED CONSTRUCTION: COMPLY WITH UNDERWRITER'S LABORATORIES CERTIFIED FIRE TESTS AND APPLICABLE CODE REQUIREMENTS. 1.SHAFT WALL SYSTEM: PROVIDE AT SHAFTS AND WHERE INDICATED. K.ACOUSTICAL ACCESSORIES: PROVIDE ASTM C665, TYPE I ACOUSTICAL INSULATION AND ASTM C919 PAINTABLE ACOUSTICAL SEALANTS WHERE ACOUSTICAL SYSTEMS ARE INDICATED. L.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED STANDARDS, AND APPLICABLE REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS. M.METAL FRAMING ERECTION: ERECT METAL FRAMING IN ACCORDANCE WITH ASTM C754 AND MANUFACTURER'S RECOMMENDATIONS. 1.INSTALL MEMBERS TRUE TO LINES AND LEVELS TO PROVIDE SURFACE FLATNESS WITH MAXIMUM VARIATION OF 1/8" IN 10'-0" IN ANY DIRECTION. 2.DOOR OPENING FRAMING: INSTALL DOUBLE STUDS AT DOOR FRAME JAMBS; INSTALL RUNNERS ON EACH SIDE OF OPENING AT FRAME HEAD HEIGHT BETWEEN JAMB STUDS AND ADJACENT STUDS. 3.INSTALL METAL FRAMING BACKING WHERE REQUIRED FOR SUPPORT OF FIXTURES, CABINETS, ACCESSORIES AND HARDWARE. 4.COORDINATE INSTALLATION OF BUCKS, ANCHORS, BLOCKING, ELECTRICAL AND MECHANICAL WORK WHICH IS TO BE PLACED IN OR BEHIND PARTITION FRAMING; ALLOW ITEMS TO BE INSTALLED AFTER FRAMING IS COMPLETE. N.CEILING FRAMING INSTALLATION: ERECT IN ACCORDANCE WITH ASTM C754 AND MANUFACTURER'S RECOMMENDATIONS. REINFORCE OPENINGS IN CEILING SUSPENSION SYSTEM. 1.LATERALLY BRACE ENTIRE SUSPENSION SYSTEM. O.GYPSUM BOARD INSTALLATION: INSTALL IN ACCORDANCE WITH ASTM C840 AND MANUFACTURER'S RECOMMENDATIONS. USE SCREWS WHEN FASTENING GYPSUM BOARD TO FURRING AND TO FRAMING. 1.FOR FIRE RATED SYSTEMS COMPLY WITH REQUIREMENTS FOR FIRE RATINGS. 2.PLACE CORNER BEADS AT EXTERNAL CORNERS; USE LONGEST PRACTICAL LENGTHS. 3.PLACE EDGE TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. 4.TAPE, FILL, AND SAND EXPOSED JOINTS, EDGES, CORNERS AND OPENINGS TO PRODUCE SURFACE READY TO RECEIVE FINISHES; FEATHER COATS ONTO ADJOINING SURFACES. 5.FINISHING: COMPLY WITH GYPSUM ASSOCIATION (GA) "LEVELS OF GYPSUM BOARD FINISH" GA LEVEL 4, THREE COAT FINISHING AND SANDING IS REQUIRED FOR ALL SURFACES TO BE FINISHED; PROVIDE FLUSH, SMOOTH JOINTS AND SURFACES READY FOR APPLIED PAINT AND WALL COVERING FINISHES. 6.REMOVE AND REPLACE DEFECTIVE WORK. P.ACOUSTICAL ACCESSORIES INSTALLATION. 1.PLACE ACOUSTICAL INSULATION TIGHT WITHIN SPACES, AROUND CUT OPENINGS, BEHIND AND AROUND ELECTRICAL AND MECHANICAL ITEMS WITHIN PARTITIONS, AND TIGHT TO ITEMS PASSING THROUGH PARTITIONS. 2.PLACE ACOUSTICAL SEALANT WITHIN PARTITIONS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS; INSTALL ACOUSTICAL SEALANT AT GYPSUM BOARD PERIMETER, AT BASE LAYER AND FACE LAYER OF GYPSUM BOARD, AND PENETRATIONS OF PARTITIONS. 3.TOLERANCE: MAXIMUM 1/4" SPACE BETWEEN GYPSUM BOARD AT FLOOR, CEILING, AND PENETRATIONS. 4.INSTALL ELECTRICAL BOX PADS WITH PADS MOLDED AND PRESSED ON BACK SIDE OF BOX, CLOSING OPENINGS, IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, FOR COMPLETE ACOUSTICAL BARRIER. SECTION 09300 - TILE A.GENERAL: PROVIDE TILE SYSTEMS INCLUDING SETTING MATERIALS, GROUT, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.STANDARDS: COMPLY WITH TILE COUNCIL OF AMERICA "HANDBOOK OF CERAMIC TILE INSTALLATION" INCLUDING REFERENCED ASTM AND ANSI STANDARDS. C.SUBMITTALS: SUBMIT PRODUCT DATA AND SAMPLES OF EACH TYPE OF TILE AND GROUT. D.TILE MANUFACTURERS: AS INDICATED ON DRAWINGS. 1.FLOOR TILE: PROVIDE NON-SLIP UNITS WITH MINIMUM WET AND DRY VALUE OF 0.60 COEFFICIENT OF FRICTION WHEN TESTED IN ACCORDANCE WITH ASTM C1028. E.LATEX THIN SET: THINSET BOND COAT, LATEX-CEMENTITIOUS MORTAR CONFORMING TO ANSI A118.4. F.GROUT: ANSI A118.6, LATEX CEMENTITIOUS TYPE BY LATICRETE, BOSTIK OR MAPEI. G.INTEGRAL WATERPROOFING: LATICRETE, BOSTIK, OR NOBEL LIQUID RUBBER INTEGRAL TILE SETTING WATERPROOFING SYSTEM WITH NO BITUMINOUS EXTENDERS; PROVIDE AT TILE APPLICATIONS ABOVE GRADE. H.CLEANING AND SEALING MATERIALS: AS RECOMMENDED BY TILE AND GROUT MANUFACTURERS, SUCH AS BOSTIK CONSTRUCTION PRODUCTS/HYDROMENT CERAMASEAL. I.PREPARATION: DO NOT COMMENCE WORK UNTIL SURFACE CONDITIONS ARE WITHIN TOLERANCES REQUIRED FOR PROPER INSTALLATION; APPLY LATEX LEVELING MATERIAL WHERE NECESSARY TO MEET REQUIRED TOLERANCES. J.INSTALLATION: COMPLY WITH TILE COUNCIL OF AMERICA (TCA) HANDBOOK FOR CERAMIC TILE INSTALLATION FOR LATEX BOND COAT THIN SET APPLICATION. 1.TILE: INSTALL TILE IN ACCORDANCE WITH REFERENCED ANSI STANDARDS AND TCA RECOMMENDATIONS FOR TYPE OF SUBSTRATE AND INDICATED SETTING METHOD; LATEX-CEMENT THIN SET AND BOND COATS REQUIRED. 2.PLACE TILE IN ACCORDANCE WITH PATTERNS INDICATED ON DRAWINGS; CAREFULLY PLAN TILE LAYOUTS, ENSURE PATTERN IS UNINTERRUPTED FROM ONE SURFACE TO THE NEXT AND THROUGH DOORWAYS. 3.SEAL TILE AND GROUT SURFACES WHERE RECOMMENDED BY MANUFACTURER FOR MATERIALS AND APPLICATIONS INVOLVED; COMPLY WITH MANUFACTURER'S RECOMMENDATIONS. SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N SPECIFICATIONS SP.2 SECTION 09510 - ACOUSTICAL CEILING A.GENERAL: PROVIDE ACOUSTICAL CEILINGS INCLUDING SUSPENSION SYSTEM, TRIM, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.STANDARDS: CONFORM TO ASTM C635 FOR METAL SUSPENSION SYSTEM AND ASTM C636 FOR INSTALLATION OF ACOUSTICAL CEILINGS. C.PERFORMANCE REQUIREMENTS: PROVIDE PRODUCTS LISTED BY UNDERWRITERS LABORATORIES (U.L.). 1.FLAME SPREAD/SMOKE DENSITY: PROVIDE PRODUCTS MEETING CODE REQUIREMENTS FOR MAXIMUM 25 FLAME SPREAD AND MAXIMUM 25 SMOKE DENSITY. D.SEISMIC REQUIREMENTS: COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS FOR SEISMIC BRACING OF CEILING SUSPENSION SYSTEM, AND WITH ASTM E580. E.SUBMITTALS: SUBMIT PRODUCT DATA, SHOP DRAWINGS INDICATING LAYOUT, AND SAMPLES OF GRID, TRIM, AND CEILING UNITS. F.INSTALLER: FIRM WITH MINIMUM THREE YEAR'S SUCCESSFUL EXPERIENCE IN PROJECTS OF SIMILAR TYPE AND SCOPE; ACCEPTABLE TO MANUFACTURER OF ACOUSTICAL UNITS. G.PROJECT CONDITIONS: DO NOT INSTALL CEILINGS UNTIL BUILDING IS ENCLOSED, SUFFICIENT HEAT IS PROVIDED, DUST GENERATING ACTIVITIES HAVE TERMINATED AND OVERHEAD MECHANICAL WORK IS COMPLETED, TESTED AND APPROVED; ALLOW WET WORK TO DRY PRIOR TO INSTALLATION. H.ACOUSTICAL UNITS: TYPES AND MANUFACTURERS AS INDICATED ON DRAWINGS. I.SUSPENSION SYSTEM: AS INDICATED ON DRAWINGS. J.PREPARATION: MEASURE CEILING AREA AND ESTABLISH LAYOUT OF ACOUSTICAL UNITS TO BALANCE BORDER WIDTHS AT OPPOSITE EDGES OF EACH CEILING; DO NOT USE LESS THAN HALF WIDTH UNITS AT BORDERS. 1.COORDINATE WITH OTHER WORK SUPPORTED BY OR PENETRATING THROUGH CEILINGS, INCLUDING LIGHT FIXTURES, HVAC EQUIPMENT AND PARTITION SYSTEMS. K.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, ASTM C636, AND APPLICABLE REQUIREMENTS FOR FIRE RATINGS. 1.FINISHED CEILINGS: TRUE TO LINES AND LEVELS AND FREE FROM WARPED, SOILED OR DAMAGED GRID OR ACOUSTICAL UNITS. 2.INSTALL CEILING SYSTEMS IN A MANNER CAPABLE OF SUPPORTING SUPERIMPOSED LOADS, WITH MAXIMUM PERMISSIBLE DEFLECTION OF 1/8" IN 10'-0". 3.ENSURE SUSPENSION SYSTEM IS LOCATED TO ACCOMMODATE FITTINGS AND UNITS OF EQUIPMENT WHICH IS TO BE PLACED AFTER INSTALLATION OF CEILING GRID. 4.WHERE DUCTS OR OTHER EQUIPMENT PREVENT REGULAR SPACING OF HANGERS, REINFORCE NEAREST ADJACENT HANGERS AND RELATED CARRYING CHANNELS AS REQUIRED TO SPAN REQUIRED DISTANCE. 5.INSTALL EDGE MOLDINGS AT INTERSECTION OF CEILING AND VERTICAL SURFACES, USING MAXIMUM LENGTHS, STRAIGHT, TRUE TO LINE AND LEVEL; MITER CORNERS. 6.FIT ACOUSTIC UNITS IN PLACE, FREE FROM DAMAGED EDGES OR DEFECTS DETRIMENTAL TO APPEARANCE AND FUNCTION. LAY DIRECTIONALLY PATTERNED UNITS ONE WAY WITH PATTERN AS DIRECTED. FIT BORDER UNITS NEATLY AGAINST ABUTTING SURFACES. 7.INSTALL UNITS LEVEL, IN UNIFORM PLANE AND FREE FROM TWIST, WARP AND DENTS. 8.INSTALL HOLD-DOWN CLIPS WHERE REQUIRED BY APPLICABLE CODES AND WHERE CEILING IS WITHIN 20'-0" OF AN EXTERIOR DOOR. L.ADJUSTMENT: ADJUST SAGS OR TWISTS WHICH DEVELOP IN CEILING SYSTEM AND REPLACE ANY PART WHICH IS DAMAGED OR FAULTY. SECTION 09650 - RESILIENT TILE FLOORING A.GENERAL: PROVIDE RESILIENT TILE FLOORING SYSTEM AND RESILIENT BASE, WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF FLOORING AND BASE COLOR AND PATTERN SELECTED. C.PROJECT CONDITIONS: ENSURE FLOOR SURFACES ARE SMOOTH AND FLAT WITH MAXIMUM VARIATION OF 1/8" IN 10'-0"; ENSURE CONCRETE FLOORS ARE DRY AND EXHIBIT NEGATIVE ALKALINITY, CARBONIZING AND DUSTING. D.RESILIENT TILE: VINYL COMPOSITION TILE CONFORMING TO ASTM F1066, COMPOSITION 1; COLOR AND PATTERN AS INDICATED ON THE DRAWINGS. 1.MANUFACTURERS/PRODUCTS: AS INDICATED ON THE DRAWINGS. 2.FLAMMABILITY: PROVIDE MATERIALS TESTED UNDER ASTM E648, FLOORING RADIANT PANEL TEST, WITH RESULTS OF 0.45 WATTS/CM2 OR HIGHER. 3.SLIP RESISTANCE: PROVIDE MATERIALS TESTED UNDER ASTM D2047, JAMES SLIP TEST WITH MINIMUM 0.6 RATING FOR FLOORS. E.RESILIENT BASE: FS SS-W-40, 1/8" GAGE COVED BASE AT HARD FLOOR SURFACES, STRAIGHT (TOP SET) AT CARPET SURFACES; PROVIDE PREMOLDED END STOPS AND EXTERNAL CORNERS. 1.MANUFACTURERS: AS INDICATED ON THE DRAWINGS. 2.HEIGHT: 4" UNLESS OTHERWISE INDICATED. 3.COLOR: SEE FINISH SCHEDULE. F.EDGE STRIPS AND ACCESSORIES: RUBBER OR VINYL EDGE STRIPS MATCHING RESILIENT FLOORING; LATEX-MODIFIED PORTLAND CEMENT BASED UNDERLAYMENT AND PATCHING COMPOUND; NONTOXIC WATER RESISTANT TYPE ADHESIVES. G.SUBFLOOR FILLER: WHITE PREMIXED LATEX-CEMENT PASTE DESIGNED FOR PROVIDING THIN SOLID SURFACE FOR LEVELING AND MINOR RAMPING OF SUBSURFACE TO ADJACENT FLOOR FINISHES; MATERIAL CAPABLE OF BEING APPLIED AND FEATHERED OUT TO ADJACENT FLOOR WITHOUT SPALLING. H.PRIMERS AND ADHESIVES: WATERPROOF NONTOXIC TYPES AS RECOMMENDED BY FLOORING MANUFACTURER FOR SPECIFIED MATERIAL AND APPLICATION. I.SEALER AND WAX: TYPE RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIAL TYPE AND LOCATION. J.PREPARATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION AND WITH ASTM F710; REMOVE SUBFLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS, JOINTS, HOLES AND DEFECTS WITH SUBFLOOR FILLER. K.FLOORING INSTALLATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER TO ENSURE FULL ADHESION; SCRIBE FLOORING TO WALLS, COLUMNS, AND OTHER APPURTENANCES TO PRODUCE TIGHT JOINTS. 1.INSTALL MINIMUM 1/2 TILE AT ROOM AND AREA PERIMETER; TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR OPENINGS WHERE ADJACENT FLOOR FINISH IS DISSIMILAR; INSTALL EDGE STRIPS AT UNPROTECTED AND EXPOSED EDGES WHERE FLOORING TERMINATES. L.BASE INSTALLATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; APPLY TO WALLS, COLUMNS, PILASTERS, CASEWORK, AND OTHER PERMANENT FIXTURES IN ROOMS AND AREAS WHERE BASE IS REQUIRED. 1.MITER INTERNAL CORNERS; USE PREMOLDED SECTIONS FOR EXTERNAL CORNERS AND EXPOSED ENDS; SCRIBE AND FIT TO DOOR FRAMES AND OTHER OBSTRUCTIONS. M.EDGE STRIPS: INSTALL WHERE EDGE OF TILE WOULD OTHERWISE BE EXPOSED; BUTT TO FLOORING WITHOUT GAPS; SET IN ADHESIVE. N.CLEANING: CLEAN, SEAL AND WAX FLOOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SECTION 09655 - RESILIENT SHEET FLOORING A.GENERAL: PROVIDE RESILIENT SHEET FLOORING WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF FLOORING COLOR AND PATTERN SELECTED AND EACH TYPE OF EXPOSED INTEGRAL BASE ACCESSORY. C.PROJECT CONDITIONS: ENSURE FLOOR SURFACES ARE SMOOTH AND FLAT WITH MAXIMUM VARIATION OF 1/8" IN 10'-0"; ENSURE CONCRETE FLOORS ARE DRY AND EXHIBIT NEGATIVE ALKALINITY, CARBONIZING AND DUSTING. D.VINYL SHEET FLOORING: NOMINAL 0.080" THICK VINYL SHEET CONFORMING TO FS L-F-475, TYPE II, GRADE A.; COLOR AS INDICATED, AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE OF COLORS WHERE NOT OTHERWISE INDICATED. 1.MANUFACTURERS: LONSEAL, MANNINGTON, OR TOLI. 2.FLAMMABILITY: 0.45 WATTS/SQ.CM. OR HIGHER, ASTM E648. E.INTEGRAL BASE ACCESSORIES: PROVIDE MANUFACTURER'S STANDARD COVE SUPPORT STRIPS AND FINISHED METAL TOP EDGE STRIPS; TYPE AND COLORS AS SELECTED BY ARCHITECT FROM MANUFACTURERS FULL RANGE. F.EDGE STRIPS AND ACCESSORIES: RUBBER OR VINYL EDGE STRIPS MATCHING RESILIENT FLOORING. G.SUBFLOOR FILLER: WHITE PREMIXED LATEX-CEMENT PASTE DESIGNED FOR PROVIDING THIN SOLID SURFACE FOR LEVELING AND MINOR RAMPING OF SUBSURFACE TO ADJACENT FLOOR FINISHES. USE MATERIAL CAPABLE OF BEING APPLIED AND FEATHERED OUT TO ADJACENT FLOOR WITHOUT SPALLING. H.PRIMERS AND ADHESIVES: WATERPROOF NONTOXIC TYPES AS RECOMMENDED BY FLOORING MANUFACTURER FOR SPECIFIED MATERIAL AND APPLICATION. I.SEALER AND WAX: TYPE RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIAL TYPE AND LOCATION. J.PREPARATION: CONFORM WITH ASTM F710 AND MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION; REMOVE SUBFLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS, JOINTS, HOLES AND DEFECTS WITH SUBFLOOR FILLER. K.INSTALLATION: COMPLY WITH FLOORING AND BASE MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER FOR FULL ADHESION; SCRIBE TO WALLS, COLUMNS, AND OTHER APPURTENANCES TO PRODUCE TIGHT JOINTS 1.LAY FLOORING WITH MINIMUM SEAMS, WITH PATTERN PARALLEL TO BUILDING LINES TO PRODUCE SYMMETRICAL PATTERN; TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR OPENINGS WHERE ADJACENT FLOOR FINISH IS DISSIMILAR; INSTALL EDGE STRIPS AT UNPROTECTED OR EXPOSED EDGES. L.WAXING: CLEAN, SEAL AND WAX FLOOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. M.CLEANING: REMOVE EXCESS ADHESIVE FROM FLOOR, BASE AND WALL SURFACES. SECTION 09680 - CARPET A.GENERAL: PROVIDE CARPET AND ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION. B.STANDARDS: CRI 104 - STANDARD FOR INSTALLATION OF COMMERCIAL TEXTILE FLOOR COVERING MATERIALS. C.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF CARPET SPECIFIED. D.INSTALLER: FIRM WITH MINIMUM FIVE YEARS EXPERIENCE IN PROJECTS OF SIMILAR TYPE AND SCOPE. E.MANUFACTURERS AND PRODUCTS: AS INDICATED ON THE DRAWINGS. F.ACCESSORIES: 1.SUB-FLOOR FILLER AS RECOMMENDED BY MANUFACTURER. 2.ADHESIVES COMPATIBLE WITH MATERIALS BEING ADHERED, INCLUDING SEAM ADHESIVE AND CONTACT ADHESIVE. G.PREPARATION: VERIFY AND CONFORM WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION; REMOVE SUB-FLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS, JOINTS, HOLES, AND DEFECTS WITH SUBFLOOR FILLER. H.THOROUGHLY CLEAN SUBSTRATE. I.INSTALLATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. 1.VERIFY CARPET MATCH BEFORE CUTTING TO ENSURE MINIMAL VARIATION BETWEEN DYE LOTS. 2.LOCATE SEAMS IN AREA OF LEAST TRAFFIC, DO NOT LOCATE SEAMS PERPENDICULAR THROUGH DOOR OPENINGS. 3.ALIGN RUN OF PILE IN SAME DIRECTION AS ANTICIPATED TRAFFIC AND IN SAME DIRECTION ON ADJACENT PIECES. 4.LOCATE CHANGE OF COLOR OR PATTERN BETWEEN ROOMS UNDER DOOR CENTERLINE. J.DIRECT GLUE CARPET: 1.DOUBLE CUT CARPET SEAMS, WITH ACCURATE PATTERN MATCH. MAKE CUTS STRAIGHT, TRUE, AND UNFRAYED. 2.APPLY CONTACT ADHESIVE TO FLOOR UNIFORMLY AT RATE RECOMMENDED BY MANUFACTURER. AFTER SUFFICIENT TIME, PRESS CARPET INTO ADHESIVE. 3.APPLY SEAM ADHESIVE TO THE BASE OF THE EDGE GLUED DOWN. LAY ADJOINING PIECE WITH SEAM STRAIGHT, NOT OVERLAPPED OR PEAKED, AND FREE OF GAPS. 4.ROLL WITH APPROPRIATE ROLLER OF COMPLETE CONTACT OF ADHESIVE TO CARPET BACKING, TRIM NEATLY AT WALL AND AROUND INTERRUPTIONS. K.CARPET TILES: 1.BLEND CARPET FROM DIFFERENT CARTONS TO ENSURE MINIMAL VARIATION IN COLOR MATCH. 2.CUT CARPET TILE CLEAN. FIT CARPET TIGHT TO INTERSECTION WITH VERTICAL SURFACES WITHOUT GAPS. 3.LAY CARPET TILE IN PATTERN INDICATED ON THE DRAWINGS. 4.LOCATE CHANGE OF COLOR OR PATTERN BETWEEN ROOMS UNDER DOOR CENTERLINE. 5.FULLY ADHERE CARPET TILE TO SUBSTRATE. 6.TRIM NEATLY AT WALLS AND AROUND INTERRUPTIONS, COMPLETE INSTALLATION OF EDGE STRIPS, CONCEALING EXPOSED EDGES. L.REMOVE EXCESS ADHESIVES WITHOUT DAMAGE, FROM FLOOR, BASE AND WALL SURFACES. M.CLEAN AND VACUUM CARPET SURFACES. SECTION 09900 - PAINTS AND COATINGS A.GENERAL: PROVIDE PAINTING OF EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.SURFACES NOT TO BE PAINTED: PREFINISHED ITEMS; CONCEALED AND INACCESSIBLE AREAS, CODE-REQUIRED LABELS. C.STANDARDS: PROVIDE MATERIALS APPROVED FOR USE BY APPLICABLE AIR QUALITY MANAGEMENT DISTRICT FOR LIMITATIONS OF VOLATILE ORGANIC COMPOUNDS FOR ARCHITECTURAL COATINGS. D.SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES. 1.DUPLICATE PAINTED FINISHES OF APPROVED SAMPLES ON ACTUAL WALL SURFACES AND COMPONENTS FOR APPROVAL PRIOR TO COMMENCING WORK. E.DELIVERY: DELIVER MATERIALS TO JOB SITE IN ORIGINAL, NEW AND UNOPENED PACKAGES AND CONTAINERS BEARING MANUFACTURER'S NAME AND LABEL. F.MANUFACTURERS: SHERWIN-WILLIAMS OR BENJAMIN MOORE. G.MATERIAL QUALITY: PROVIDE TOP LINE QUALITY COMMERCIAL GRADE (PROFESSIONAL PAINTER) PAINTS; MATERIALS NOT BEARING MANUFACTURER'S IDENTIFICATION AS A BEST-GRADE PRODUCT SHALL NOT BE ACCEPTABLE. 1.PRIMERS: PROVIDE PREMIUM GRADE PRIMERS RECOMMENDED BY PAINT MANUFACTURER FOR SUBSTRATES INDICATED AND FOR FINISH SYSTEMS SPECIFIED. 2.UNDERCOATS AND BARRIER COATS: PROVIDE UNDERCOAT PAINTS PRODUCED BY SAME MANUFACTURER AS FINISH COATS; USE ONLY THINNERS APPROVED BY PAINT MANUFACTURER, AND USE ONLY WITHIN RECOMMENDED LIMITS. 3.FINISH COATS: PROVIDE FINISH COATS CAPABLE OF BEING WASHED WITH MILD DETERGENT WITHOUT LOSS OF COLOR, SHEEN, OR PIGMENTS. 4.FINISH COAT COORDINATION: PROVIDE FINISH COATS WHICH ARE COMPATIBLE WITH PRIME PAINTS, UNDERCOATS, AND BARRIER COATS USED. 5.VOLATILE ORGANIC COMPOUNDS: PROVIDE MATERIALS WITH MINIMAL VOLATILE ORGANIC COMPOUNDS (VOC); COMPLY WITH APPLICABLE REGULATIONS. H.COLORS AND FINISHES: PURE, NON-FADING, APPLICABLE TYPES TO SUIT SERVICE INDICATED; NO LEAD CONTENT PERMITTED. 1.COLORS AS INDICATED ON THE DRAWINGS. I.PREPARATION: PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH PAINT MANUFACTURER'S INSTRUCTIONS AND AS SPECIFIED FOR SUBSTRATE CONDITION. 1.EXAMINE AREAS AND CONDITIONS UNDER WHICH PAINTING WORK IS TO BE APPLIED. START OF PAINTING WORK INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS OF SURFACES AND CONDITIONS WITHIN ANY PARTICULAR AREA. 2.REMOVE HARDWARE, ACCESSORIES, AND ITEMS IN PLACE AND NOT TO BE PAINTED, OR PROVIDE PROTECTION PRIOR TO SURFACE PREPARATION AND PAINTING; AFTER PAINTING REINSTALL REMOVED ITEMS. J.APPLICATION: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS; USE APPLICATORS AND TECHNIQUES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. 1.APPLY ADDITIONAL COATS WHEN STAINS OR BLEMISHES SHOW THROUGH FINAL COAT, UNTIL PAINT IS A UNIFORM FINISH, COLOR AND APPEARANCE. 2.FINISH DOORS ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES. 3.PROVIDE EXTRA ATTENTION TO ASSURE DRY FILM THICKNESS AT CORNERS AND CREVICES IS EQUIVALENT TO THAT OF FLAT SURFACES. 4.PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS SIMILAR EXPOSED SURFACES; PAINT SURFACES BEHIND PERMANENTLY-FIXED EQUIPMENT AND FURNITURE WITH PRIME COAT ONLY. 5.PAINT INTERIOR SURFACES OF DUCTS, WHERE VISIBLE THROUGH REGISTERS OR GRILLES, WITH A FLAT, NON-SPECULAR BLACK PAINT. 6.PAINT BACK SIDES OF ACCESS PANELS AND REMOVABLE OR HINGED COVERS TO MATCH EXPOSED SURFACES. 7.FINISH DOORS ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES. 8.SAND LIGHTLY BETWEEN EACH SUCCEEDING ENAMEL AND EACH VARNISH COAT. K.SCHEDULING PAINTING: APPLY FIRST COAT TO SURFACES THAT HAVE BEEN CLEANED, PRETREATED OR PREPARED FOR PAINTING AS SOON AS PRACTICABLE AFTER PREPARATION. 1.ALLOW TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPER DRYING. DO NOT RECOAT UNTIL PAINT FEELS FIRM AND DOES NOT DEFORM OR FEEL STICKY UNDER MODERATE THUMB PRESSURE. L.MINIMUM COATING THICKNESS: APPLY MATERIALS AT NOT LESS THAN MANUFACTURER'S RECOMMENDED SPREADING RATE, TO ESTABLISH A TOTAL DRY FILM THICKNESS AS RECOMMENDED BY COATING MANUFACTURER. M.PRIME COATS: APPLY TO ITEMS NOT PREVIOUSLY PRIMED; RECOAT PRIMED AND SEALED SURFACES WHERE THERE IS EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST COAT. N.FINISH COATS: PROVIDE EVEN TEXTURE; LEAVE NO LAPS, IRREGULARITY IN TEXTURE, SKID MARKS, OR OTHER SURFACE IMPERFECTIONS. O.CLEAN-UP: DURING PROGRESS OF WORK, REMOVE DISCARDED PAINT MATERIALS, RUBBISH, CANS AND RAGS FROM SITE AT END OF EACH WORK DAY. 1.CLEAN GLASS AND PAINT-SPATTERED SURFACES IMMEDIATELY BY PROPER METHODS OF WASHING AND SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FINISHED SURFACES. P.PROTECTION: PROTECT WORK OF OTHER TRADES, WHETHER TO BE PAINTED OR NOT; CORRECT DAMAGE BY CLEANING, REPAIRING OR REPLACING, AND REPAINTING, AS ACCEPTABLE TO ARCHITECT. 1.PROVIDE "WET PAINT" SIGNS TO PROTECT NEWLY-PAINTED FINISHES. 2.REMOVE TEMPORARY PROTECTIVE WRAPPINGS PROVIDED BY OTHERS FOR PROTECTION OF THEIR WORK, AFTER COMPLETION OF PAINTING OPERATIONS. Q.REPAIR: AT COMPLETION OF WORK OF OTHER TRADES, TOUCH-UP AND RESTORE DAMAGED SURFACES OR DEFACED PAINTED SURFACES. DIVISION TEN: SPECIALTIES SECTION 10520 - FIRE EXTINGUISHERS AND CABINETS A.GENERAL: PROVIDE FIRE EXTINGUISHERS AND CABINETS, ALONG WITH REQUIRED ACCESSORIES AS REQUIRED FOR A COMPLETE INSTALLATION AND SATISFY THE REQUIREMENTS OF THE GOVERNING AUTHORITIES. B.STANDARDS: NFPA 10 - STANDARD FOR PORTABLE FIRE EXTINGUISHERS, AND U.L. - FIRE PROTECTION EQUIPMENT DIRECTORY. C.SUBMITTALS: PRODUCT DATA. D.MANUFACTURERS: JL INDUSTRIES, LARSEN'S MANUFACTURING, OR APPROVED EQUAL. E.FIRE EXTINGUISHERS: COMPLY WITH PRODUCT REQUIREMENTS OF NFPA 10 AND APPLICABLE CODES. PROVIDE EXTINGUISHERS LABELED BY UNDERWRITERS LABORATORIES, INC. FOR THE PURPOSE SPECIFIED OR INDICATED. 1.MULTI-PURPOSE DRY CHEMICAL TYPE FIRE EXTINGUISHERS - STAINLESS STEEL TANK WITH PRESSURE GAUGE, CLASS B,C (SIZE 10) FINISH: RED, BAKED ENAMEL. F.FIRE EXTINGUISHER CABINETS: SEMI-RECESSED TYPE SIZE TO ACCOMMODATE EXTINGUISHER AND ACCESSORIES. 1.FORMED METAL CABINET OF 0.036 INCH MATERIAL WITH FLAT TRIM AT FACE AND RETURNS TO WALL. 2.DOOR WITH 18" THICK CLEAR TEMP. GLAZING, HINGED FOR 180 DEGREE OPENING WITH CONTINUOUS PIANO TYPE HINGE. 3.EXTERIOR AND INTERIOR OF CABINET TO BE BAKED WHITE ENAMEL FINISH. G.ACCESSORIES: EXTINGUISHER BRACKETS - FORMED STEEL, CHROME PLATED. H.INSTALL IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. 1.INSTALL CABINETS PLUMB AND LEVEL, SECURED RIGIDLY IN PLACE. 2.VERIFY ALL LOCATIONS WITH LOCAL FIRE MARSHALL PRIOR TO INSTALLATION. I.SCHEDULE: 1.GENERAL AREAS, HALLWAYS, ETC.: SEMI-RECESSED CABINET WITH MULTI-PURPOSE DRY TYPE EXTINGUISHER AS LOCATED ON THE DRAWINGS. 2.UTILITY ROOM: WALL MOUNTED EXTINGUISHER BRACKET WITH MULTI-PURPOSE DRY TYPE EXTINGUISHER AS LOCATED ON THE DRAWINGS. SECTION 10810 - TOILET ACCESSORIES A.GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B.CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS WITH DISABILITIES. C.SUBMITTALS: SUBMIT PRODUCT DATA. D.MANUFACTURERS: BOBRICK, BRADLEY, OR AMERICAN SPECIALTIES. E.TYPES: STAINLESS STEEL ACCESSORIES AS INDICATED ON DRAWINGS; PROVIDE GRAB BARS WITH CONCEALED MOUNTING, SIZES AND SHAPES AS INDICATED AND AS REQUIRED BY APPLICABLE CODES AND REGULATIONS. F.MATERIALS: STAINLESS STEEL, ASTM A666 / ASTM A269, COMMERCIAL GRADE, TYPE 302/304, NUMBER 4 SATIN FINISH, SATIN CHROME ACCEPTABLE WHERE STAINLESS STEEL IS NOT AVAILABLE FOR ACCESSORY ITEM SCHEDULED; GAGES AS STANDARD WITH MANUFACTURER OF SPECIFIED ITEMS. 1.FASTENERS, SCREWS, AND BOLTS: HOT DIP GALVANIZED; AS RECOMMENDED BY ACCESSORY MANUFACTURER FOR COMPONENT AND SUBSTRATE. 2.CONCEALED SURFACES: PRETREAT AND CLEAN, SPRAY APPLY ONE COAT PRIMER AND BAKED ENAMEL FINISH. G.FABRICATION: WELD AND GRIND SMOOTH JOINTS OF FABRICATED COMPONENTS; FORM EXPOSED SURFACES FROM ONE SHEET OF STOCK, FREE OF JOINTS. 1.FABRICATE UNITS WITH TIGHT SEAMS AND JOINTS, EXPOSED EDGES ROLLED; HANG DOORS AND ACCESS PANELS WITH CONTINUOUS PIANO HINGES; PROVIDE CONCEALED ANCHORAGE WHERE POSSIBLE. 2.PROVIDE STEEL ANCHOR PLATES AND ANCHOR COMPONENTS FOR INSTALLATION. 3.FORM SURFACES FLAT WITHOUT DISTORTION; MAINTAIN FLAT SURFACES WITHOUT SCRATCHES AND WITHOUT DENTS; FINISH EXPOSED EDGES EASED, FREE OF SHARP EDGES WHERE POTENTIAL EXISTS FOR PHYSICAL CONTACT. 4.HOT DIP GALVANIZE FERROUS METAL ANCHORS AND FASTENING DEVICES. 5.SHOP ASSEMBLE COMPONENTS; PACKAGE COMPLETE WITH ANCHORS AND FITTINGS. H.INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS. 1.PROVIDE/DELIVER INSERTS, TEMPLATES, ADN ROUGH IN MEASUREMENTS TO SITE FOR A TIMELY INSTALLATION. 2.INSTALL PLUMB AND LEVEL, SECURELY AND RIGIDLY ANCHORED TO SUBSTRATE. 3.MOUNTING HEIGHTS AND LOCATIONS: AS REQUIRED BY ACCESSIBILITY REGULATIONS AND AS INDICATED ON THE DRAWINGS. DIVISION ELEVEN: EQUIPMENT (NOT USED) DIVISION TWELVE: FURNISHINGS (NOT USED) DIVISION THIRTEEN: SPECIAL CONSTRUCTION (NOT USED) DIVISION FOURTEEN: CONVEYING SYSTEMS (NOT USED) DIVISION FIFTEEN: MECHANICAL REFER TO MECHANICAL DRAWINGS. DIVISION SIXTEEN: ELECTRICAL REFER TO MECHANICAL DRAWINGS. SHEET TITLE: SEAL/SIGNATURE: ISSUES AND REVISIONS: PROJECT NO.: DRAWN BY: CHECKED BY: PROJECT: MERCHANT'S SQUARE 2316 EAST 116TH STREET CARMEL, INDIANA 46032 12039 RLO SAW / MCF SALON LOFTS PROJECT NO.: ININD-002 2145 Ford Parkway, Suite 301 Saint Paul, Minnesota 55116651.690.5525 Fax 690.5545www.finn-daniels.com SALON LOFTS CLIENT REVIEW SET 12.07.2012 PERMIT ISSUE 12.10.2012 IA N AIND I T E C T * A RCH * IFC.KRAM N A M ENN N SPECIFICATIONS SP.3