Loading...
HomeMy WebLinkAbout05040140-Site Plan Gar. FFE = 90~ Ist Fir FFE Ssmt FFE = 892,0I LDdve Slope = 1,1%j Note: Contractor shou~ verify site specific information depictad hereon with the approved construction plans for this development _+14,960 SF MFPG 896.0 PER PLAN Note: Minimum Front yard - 20' Minimum Side Yard - 5' Minimum Side Yard Aggregate - 15' Minimum Rear Yard - 20' TC=901 ME 't60.00' 160,00' ME 10.5' [~ = Proposed Grade ~ = Drainage Flow XX.X = Existing Grade Flood Hazard Note: .et Number 60 lies within Zone "X" per the scaled tocation on th6 Flood Insurance Rate Maps for Hamilton County, Indiana (Community Panel #18057C0205F dated February 19. 2003). Note: This drawing is based upon construction plans and/or record drawings prepared by others and is not based upon a field survey. COOR Consulting & Land Services. Corp. does not warrant the correc[ness or integrity of this information. The contractor/owner should verify existing conditions pdor to construction. Any varying tield conditions or any discrepancy with the information contained hereon should be immediately reported to COOR Consulting & Land Services, CorD,; failure to do so would result in the contractor/owners assumption of liability, PAGE 1 OF 2 303 WEST MAIN STREET KNIGHTSTOWN. '888] 593-2667 [765) 345-5943 FAX#: (765] 345-5692 DATE: 0322~05 JOB #2004-060.060 REVISIONS: Conc Flatwork Sq, Ft = +17371 Public Walk Sq Ft = +374 t Sod Sq Yds = ±2,60 / Seeding Sq Ft = ±8396 J The proposed construction grades depicted hereonare based upon information, proposed grades and/or contours, taken from the approved construction plans prepared for this subdivision. Unless stated hereon, no information pertaining to but not limited to, fluctuating water table elevations, soil types or conditions within the building area of said lot, has been provided or referenced on said plans. With the construction of a basement it is recommended that the lowest floor elevation be constructed at least two (2) feet above any adjoining bodies of water unless a stuoy of facts reveals otherwise. Should any ground water be witnessed during the excavation of said structure, the lowest floor aievation should be raised at least two (2) [eet above the ground water evai and additional construction technk~ues should be rncorporatea to alleviate future problems, VILLAGE OF WESTCLAY SECTION 9005 INSTR #200400055156 PC 3. SLIDE 459 LOT # 60 1853 HALIFAX STREET CARMEL N 46032 PLOT PLAN Prepared For: F'ulte Homes of Indiana